About this file
This document is a Summary of Work section for the John Day Powerhouse Security System Upgrades project. The contract requires comprehensive security system upgrades at the John Day Dam, located on the border of Oregon and Washington, accessible from I-84 and Highway 14. The work scope includes replacing multiple light fixtures, upgrading the Electronic Security System (ESS), installing server room infrastructure, replacing ESS wiring, providing HVAC for the server room, implementing a redundant monitoring system in the powerhouse control room, and adding security cameras, card readers, and door alarms.
The government will furnish an extensive list of equipment for the project, including Cisco networking switches, firewalls, Dell servers, workstations, laptops, network-attached storage (NAS), cameras, badging equipment, and various supporting accessories. Key equipment includes Cisco C9500 and C9300 switches, PA-850 network security appliances, PowerEdge servers, Precision workstations, AXIS cameras, and a Fargo card printer. The contract requires the contractor to install and integrate these government-provided items into the existing infrastructure, with careful coordination to minimize disruption to the ongoing operations of the John Day Powerhouse.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| John Day Security Summary of Work and CLINs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 01 11 00.00 25
SUMMARY OF WORK
09/2016
PART 1 GENERAL
1.1 SUMMARY
This Section provides a summary of the various Contract work elements and their relationship to each other. This summary describes work activities within interim construction completion dates. This Section does not provide the technical detail for particular work activities, but describes the work as a whole, providing overall perspective to the separate tasks and their interrelationships. Use this Section in conjunction with all the Specification Sections and the Drawings to establish the total work requirements.
1.2 WORK COVERED BY CONTRACT DOCUMENTS
1.2.1 Project Description
The work includes providing all labor, equipment, and materials required to complete construction of the John Day Powerhouse Security System Upgrades project per the Contract specifications and plan drawings. This work includes, but is not limited to:
a. Replacing multiple light fixtures throughout John Day Dam
b. Replacing the existing Electronic Security System (ESS)
c. Power, lighting, and installation of server racks in server room
d. Replacing existing ESS wiring as shown on drawings
e. Providing Heating, Ventilation, and Air Conditioning (HVAC) to the server room
f. Providing a redundant monitoring system within the Powerhouse control room
g. Providing additional security cameras and light fixtures where described on the drawings
h. Installing additional card readers and door alarms per the drawings
i. Any incidental work related to the above
1.2.2 Location
The work site is located at John Day Powerhouse. Contractor access to the work site will be from exit 109 on I-84 and John Day Dam Road on the Oregon state side or Highway 14 and John Day Dam Road on the Washington state side.
1.3 CONTRACT DRAWINGS
a. The Drawings that accompany these Specifications are a part thereof.
b. Immediately check furnished drawings, maps, and specifications and notify the Government of any discrepancies.
1.4 OCCUPANCY OF PREMISES
Building(s) will be occupied during performance of work under this Contract.
1.5 EXISTING WORK
In addition to FAR 52.236-9, PROTECTION OF EXISTING VEGETATION, STRUCTURES, EQUIPMENT, UTILITIES, AND IMPROVEMENTS:
a. Remove or alter existing work in such a manner as to prevent injury or damage to any portion of the existing work to remain.
b. Upon completion of the work, repair or replace portions of existing work, which have been damaged by Contractor's operations, to Preconstruction conditions at the expense of the Contractor.
1.6 GOVERNMENT-FURNISHED MATERIAL AND EQUIPMENT
Pursuant to Contract Clause 52.245-1, GOVERNMENT PROPERTY, the Government will furnish the following materials and equipment for installation by the Contractor:
ITEM NO. DESCRIPTION QUANTITY
ODJ-ESS-Switch-01 Cisco C9500-48-port x1/10/25G+4-port 40/100G, Advantage
ODJ-ESS-Switch-01a 650W AC Config 4 Power Supply front to back cooling
ODJ-ESS-Switch-01b CATALYST 9500 SERIES NETWORK MODULE
8-PORT 10 GIGABIT ETHERNET WITH SFP+
ODJ-ESS-Switch-01c Cisco Catalyst 9500 DNA Advantage 3 Year License
ODJ-ESS-Switch-02 Catalyst 9300 48-port data only, Network Advantage
ODJ-ESS-Switch-02a C9300 DNA Advantage, 48 Port 3 Year Term License
ODJ-ESS-Switch-02b Cisco 350W AC 80+ Power Supply 2
ODJ-ESS-Switch-02c Catalyst 9300 8 x 10GE Network Module 1
ODJ-ESS-Switch-03 CISCO WS-C9200CX-12P-2X2G Ethernet Switch
ODJ-ESS-Switch-03a Cisco Catalyst Advantage, Subscription License, 1 Switch (12 Ports), 1 Year
ODJ-ESS-Firewall-01 PA-850 NETWORK SECURITY/FIREWALL
APPLIANCE
ODJ-ESS-Firewall-02 Threat Protection 5 year license 2
ITEM NO. DESCRIPTION QUANTITY
ODJ-ESS-Firewall-03 Premium Support 5 Year Prepaid 2
ODJ-ESS-Server-01 PowerEdge R660xs Server Intel Xeon Gold 6426Y, 16C 128GB total, either 8x16GB or 4x32GB 4x 3.2TB Enterprise NVMe Mixed Use, U2, G4, P5620 BOSS-N1 controller card + with 2 M.2
480GB - (RAID 1)
Broadcom 5720 DualPort 1Gb On-Board Broadcom 57504 Quad Port 10/25Gbe
SFP28
1x Dell Networking, Cable, SFP28 to SFP28, 25GbE 7 Years Prosupport Next Business Day 7 Years Keep your Hard Drive
ODJ-ESS-Server-02 Microsoft SQL Server Standard Edition 1
ODJ-ESS-Server-03 Microsoft SQL Device CAL 10
ODJ-ESS-Server-04 ELM Enterprise Manager 8.0 Class 1 System License x2 Class 1 Event License x15 Class 2 Event License x10 Class 2 Network License x40
ODJ-ESS-Server-05 Enterprise IP Camera license 12 ODJ-ESS-Server-06 Exacq X-Series 1U Server
Intel Xeon E-2334G 6Cores/12 Threads Windows Server 2022 RAM 16GB total, 2x8GB 240GB, Dual SSD, RAID 1 4 x 12 TB Video Storage Hot Swap iDRAC 9, iDRAC RESTful APO w/ Redfish, iDRAC SM NIC 2 x 1GbE & 4 x 1GbE Warranty 5 Years Keep your HDD's 8 IP Camera Licenses per server (Pro or Enterprise) 5 year SSA included
ODJ-ESS-Server-07 Acronis Cyber Protect Backup Advanced 7 Workstation 10 Server 2 Virtual Host 5 year license
ODJ-ESS-Workstation-01Precision 3930 Rack Workstation Core i9-9900
32GB RAM
2TB M.2
5 Yr basic hardware
ODJ-ESS-Workstation-02Precision 3260 Compact 3260 Compact Core i7-12700
16GB RAM
512MB NVMe 4.0x4 3 Yr Onsite
ODJ-ESS-Workstation-03LENOVO QUADRO P1000 GRAPHIC CARD - 4
GB
ODJ-ESS-Workstation-04Dell 24" Monitor, Energy Star 10
ODJ-ESS-Workstation-05Samsung Signage Display 1
ODJ-ESS-Laptop-01 Precision 7560 15.6"" Mobile Core i7-11850H
16GB RAM
512GB NVMe M.2 PCI Express 3 Yr Onsite
ODJ-ESS-Laptop-02 DELL WD19TB THUNDERBOLT DOCK (BLACK) 1
ODJ-ESS-NAS-01 Rackstation RS1619XS+ 2
ODJ-ESS-NAS-01a RAIL KIT SLIDING 2
ODJ-ESS-NAS-01b SYNOLOGY M.2 22110 NVME SSD SNV3510 800G
ODJ-ESS-NAS-01c SYNOLOGY ENTERPRISE 3.5 S 8
ODJ-ESS-KVM-01 Dell Digital KVM Switch DMPU108e 1
ODJ-ESS-KVM-02 Dell FPM185 - KVM console - 18.5" 1
ODJ-ESS-Camera-01 AXIS 01154-001 POE ADAPTER GIGABIT
ETHERNET
ODJ-ESS-Camera-02 AXIS T8154 60Watt SFP Midspan 50
ODJ-ESS-Camera-03 AXIS 5801-641 SURGE PROTECTOR GRAY 50
ODJ-ESS-Camera-04 AXIS Q6075-E Full HD Network Camera, Dome, 1920 x 1080, PTZ, Outdoor
ODJ-ESS-Camera-05 AXIS Q6075 Full HD Network Camera, Dome, 1920 x 1080, PTZ, Indoor
ODJ-ESS-Camera-06 AXIS Q36 SERIES Q3628 5
ODJ-ESS-Camera-07 AXIS TQ3103-E PENDANT BRACKET 5
ODJ-ESS-Camera-08 IX-MV7-B Video Master Station 1
ODJ-ESS-Camera-09 KBD5000 Surveillance Control Panel 1
ODJ-ESS-Badging-01 Fargo DTC1250E Plastic Card Printer 1
ODJ-ESS-Badging-02 LASERJET PRO MFP M428FDN 1
ODJ-ESS-Badging-03 VALCAM PAN TILT & Zoom Photo ID Camera 1
ODJ-ESS-Time-01 Satellite-Synchronized Network Clock 1
ODJ-ESS-Reader-01 HID IDENTITY PIVCLASS RPK40-H BLACK 4
ODJ-ESS-INTERCOM-01 CONTACTLESS SMART CARD READER - WALL
SWITCH, 4.80" x 3.30" x 1.00"
ODJ-ESS-INTERCOM-02 FLUSH MOUNTED IP VIDEO DOOR STATION,
10.40" x 5.90"
a. Quantities indicated for the above-listed items marked with an asterisk are estimates. It is the intention of the Government to furnish all quantities of the asterisk items required to complete the work as specified and the various quantities will be adjusted when necessary.
b. Quantities stated for the above items not marked with an asterisk are all that will be furnished by the Government. Contractor must furnish any additional quantities required.
c. Contract Clause 252.245-7005, MANAGEMENT AND REPORTING OF GOVERNMENT PROPERTY, applies to the items listed in this Section.
PART 2 PRODUCTS
Not Used.
PART 3 EXECUTION
Prior to shutting down any cameras or other ESS equipment, coordinate with
John Day Site Security.
-- End of Section --