06 DRAFT Drawings - Dexter FF - Architectural.pdf
PDF 13 MB Posted
- Attached to
- Dexter Adult Fish Facility Upgrades
- Solicitation number
- W9127N23R0005
About this file
This document provides details on a federal contract opportunity for upgrades to the Dexter Adult Fish Facility located in Lane County, Oregon. The U.S. Army Corps of Engineers, Portland District is soliciting a firm-fixed price construction contract between $50 million to $100 million to improve, replace, and add features to the fish facility to meet criteria set by the National Marine Fisheries Service. Key project components include replacing 90% of the fish ladder and associated structures, excavating rock at the entrance, installing pre-engineered metal structures and custom fabricated pipe systems, a fish transfer system, a water distribution network, utility buildings, a maintenance building, and fish sorting equipment. The pre-solicitation notice states a mandatory site visit will be held on November 17, 2022, with responses due by December 23, 2022. The work is to be performed between March 2023 and November 2026. The procurement is unrestricted and set aside for small businesses under NAICS code 237990.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T
PORTLAND DISTRICT
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
M
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
P P
A N
D K
E Y
P L
A N
A B
B R
E V
IA
T
IO
N
S L
E G
E N
D N
O T
E S
G E
N E
R A
L
A-001
:1
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
E
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
D X
F
.1
A -0
.d g n
/0
/2
B C
O E
S R
E V
IE
W
A-000
A
BD
C
X
DIRECTION OF SECTION VIEW
SECTION IDENTIFICATION
PLATE NUMBER WHERE SECTION IS DRAWN
DIRECTION OF ELEVATION VIEW
ELEVATION IDENTIFICATION
SHEET ID WHERE ELEVATION IS DRAWN
DIRECTION OF ELEVATION VIEW
ELEVATION IDENTIFICATION
SHEET ID WHERE ELEVATION IS DRAWN
DETAIL IDENTIFICATION
SHEET ID WHERE DETAIL IS DRAWN
A-000
REFERENCE SHEET
DRAWING IDENTIFICATION
DRAWING TITLE
DRAWING SCALE
SCALE BAR
ROOM NAME
ROOM NUMBER
DOOR IDENTIFICATION NUMBER
SEE SHEET AL101
PRE-SORT POOL SHADE STRUCTURE
SEE SHEET AM101
SORTING FACILITY SHADE STRUCTURE
SEE SHEET AZ101
MECHANICAL & ELECTRICAL BUILDING
SEE SHEET AY101
MAINTENANCE & OFFICE BUILDING
EQUIPMENT ROOF, SEE SHEET AK101
LADDER ENTRANCE ELECTRICAL
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
ABBREVIATIONS REFERENCE SYMBOL LEGEND GENERAL NOTES
FIRE EXTINGUISHER CABINETFEC
INSULATED METAL PANELIMP
FINISH GRADEFG
GYPSUM WALL BOARD
HOLLOW METAL
HARDWARE
GAGE, GAUGE
HM
HDWR
GA
FACE OF CONCRETE
FINISH (ED)
ELEVATION
FIN
FF
FOC
EL
L
ANGLE
AND
TOP OF WALL
TYP
TOW
TYPICAL
CONCRETECONC
CLEAR (ANCE)CLR
ABOVE FINISHED FLOORAFF
ROUGH OPENING
RM
RO
RH
ROOM
RIGHT HAND
ON CENTER (S)OC
MANUFACTURER (ING)
MIN
MAX
MFR
MINIMUM
METAL
MAXIMUM
FINISH FLOOR
PR PAIR
MTL
GWB
REFER TO CS101 FOR SITE LAYOUT AND LOCATIONS OF BUILDINGS RELATIVE TO OTHER SITE ELEMENTS.14.
THE ATTENTION OF THE CONTRACTING OFFICER BEFORE PROCEEDING WITH THE WORK.
VERIFY ALL DIMENSIONS, EXISTING UTILITIES, FIXTURES AND CONDITIONS AT THE SITE. CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS MUST BE BROUGHT TO 13.
SELECTION OF EXTERIOR MATERIALS MUST FOLLOW COLOR AND PATTERN MATCH REQUIREMENTS INDICATED. FIELD COMPARE MATERIALS TO CONFIRM MATCH WITH EXISTING.12.
ASSEMBLIES SUCH THAT THE WALL'S RATING IS MAINTAIN.
THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PENETRATIONS IN THE STRUCTURE. SEAL ALL PENETRATIONS THROUGH RATED WALLS WITH UL LISTED 11.
PURPOSES ONLY. REFER TO DRAWINGS OF OTHER DISCIPLINES FOR SPECIFIC DESIGN INFORMATION.
CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, AND TELECOMMUNICATIONS FEATURES SHOWN ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION AND LOCATION 10.
PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING, HANGERS, OR OTHER SUPPORT FOR FIXTURES, EQUIPMENT CABINETRY, FURNISHINGS AND ITEMS REQUIRING SUPPORT.9.
WOOD IN CONTACT WITH CONCRETE SHALL BE PRESERVATIVE TREATED WOOD. ISOLATE PRESERVATIVE TREATED WOOD FROM METALS.8.
TOLERANCES AND DIMENSIONS. CONTRACTOR SHALL TRIM ITEMS TO FIT AND OTHERWISE ENSURE PROPER INSTALLATION OF WORK.
CONTRACTOR SHALL PROVIDE COMPATIBLE SHIMMING MATERIAL (PLASTIC, METAL, OR OTHER AS PERMITTED BY IBC) AS REQUIRED TO BRING CONSTRUCTION WITHIN SPECIFIED 7.
BE COMPLETELY PROVIDED AS IF NOTED IN FULL.
REPETITIVE FEATURES NOTED TYPICAL ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. REPETETIVE FEATURES NOT NOTED ON THE DRAWINGS SHALL 6.
CURBS, AND LOUVERS.
ALL OPENING DIMENSIONS ARE NOMINAL. THE CONTRACTOR SHALL FIELD MEASURE ALL OPENINGS AND COORDINATE WITH THE APPROPRIATE SUPPLIER FOR ALL DOORS, WINDOWS, 5.
NOTED OTHERWISE. GRID LINES INDICATE THE CENTER OF STRUCTURAL STEEL COLUMNS UNLESS NOTED OTHERWISE.
DIMENSIONS ARE INDICATED IN FEET AND INCHES. DIMENSIONS ARE DRAWN TO FACE OF CONCRETE, STEEL STUDS OR GIRTS, STRUCTURAL STEEL, AND METAL PANEL UNLESS 4.
REQUIREMENTS FOR EARTH, APRON, PAVEMENTS, AND LANDINGS.
PROVIDE ADEQUATE DRAINAGE FROM BUILDING EXTERIOR AND DOOR THRESHOLDS. FINISH GRADE ELEVATIONS VARY. SEE CIVIL FOR ACTUAL FINISH GRADE ELEVATION 3.
SCALE DRAWINGS.
DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS AND ELEVATIONS. LARGE SCALE DETAILS OR PLANS SHALL GOVERN OVER SMALL SCALE PLANS OR NOT TO 2.
ARCHITECTURAL DETAILS ARE INTENDED TO SHOW THE GENERAL CHARACTER AND EXTENT OF THE PROJECT. THEY ARE NOT INTENDED TO SHOW EVERY DETAIL OF THE WORK.1.
SECTIONS
ELEVATIONS
EXTERIOR
DETAILS
WINDOW AND LOUVER TAG
CENTERLINE
CENTER LINE
SPOT ELEVATION MARKER
WALL TYPE IDENTIFICATION TAG
ROOF SLOPE INDICATOR, RISE OVER RUN
KEY NOTE TAG
PEMB PRE-ENGINEERED METAL BUILDING
LIGHTLT
ELEVATIONS
INTERIOR
+/- PLUS OR MINUS
EL 281.00'
W1
A
AY101
OFFICE
TOS
CL
KEY PLAN
SCALE: X" = X'-X" 0 X X X
X
XXX
TOS TOP OF SLAB
TOP OF FINISH FLOORTOFF
HR HOUR
LHRB LEFT HAND REVERSE BEVEL
LH LEFT HAND
OVERHEAD COILING DOOROCD
AT@
XPS EXTRUDED POLYSTYRENE
NIC NOT IN CONTRACT (SHOWN FOR REFERENCE ONLY)
FINISH SCHEDULES
BATT INSULATION, SEE WALL AND
METAL STUD WALL WITH ACOUSTICAL
D CLOTHES DRYER
CLOTHES WASHERW
HW HOT WATER TANK
MS MOP SINK
PAINTEDPTD
INSUL INSULATION
STRUCTURALSTR
TOP OF CONCRETETOC
BUILDINGBLDG
CEMENTITIOUS BACKER UNITCBU
XXX
X
XXX
X
DRAFT
6'-10"
2'-9"
1'-6"
M
IN
1/2" TYP.
T
Y P
1'-6" TYP.
4'-0" TYP.
T
Y P
1 1/2 " TYP.
1"
/2
/2
M
IN
7'1'-6"
3'-5" 3'-5"
1" TYP.
ALUMINUM Z BARS
3" x 2-11/16" x 2-11/16"
THIS SHEET FOR TEXT.
SHEET. SEE DETAIL 2
1/8" THICK ALUMINUM
"B" GRADE POSTS
4x4 REDWOOD HEART
SPECIFICATIONS
FOOTING, SEE
CONCRETE
CYLINDRICAL
FINISH GRADE
FINISHED GRADE
1" ABOVE
CONCRETE TO
SLOPE TOP OF
STEEL POST BASE
GALVANIZED
12-GAUGE
CAST-IN-PLACE
SPECIFICATIONS
FOOTING, SEE
CONCRETE
CYLINDRICAL
"B" GRADE POSTS
4x6 REDWOOD HEART
THIS SHEET FOR TEXT.
SHEET. SEE DETAIL 4
1/8" THICK ALUMINUM
ANGLE BRACKET
2x2 ALUMINUM
2x2 FASTENED BY
LUMBER FRAMING,
ALUMINUM Z BARS
3" x 2-11/16" x 2-11/16"
FINISH GRADE FINISHED GRADE
1" ABOVE
CONCRETE TO
SLOPE TOP OF
STEEL POST BASE
GALVANIZED
12-GAUGE
CAST-IN-PLACE
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
P
IC
K L
E
B R
Y A
N P
IC
K
L E T
A P
T
E R
IO
R
S
IG
N S
C H
E D
U L
E A
N D
D E
T A
IL
S
G E
N E
R A
L
A-601
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
/0
/2
B C
O E
S R
E V
IE
W
D X
F
.1
A -6
.d g n
Dexter Dam
Fish Collection Facility
CASTLE TO HAVE WHITE FILL
COMMUNICATION RED
BACKGROUND COLOR:
WHITE, TYP.
TEXT COLOR:
CORPS BROWN, TYP.
SIGN BACKGROUND COLOR:
US Army Corps of Engineers
DESIGNATOR
4", TYP OF FACILITY
TEXT SIZE:
Willamette Valley Project
DIAMETER
Electrical
Room
Mechanical
Room
WHITE, TYP.
TEXT COLOR:
CORPS BROWN, TYP.
COLOR:
SIGN BACKGROUND
FOR PLACEMENT
SHEET AZ101
SEE ELEVATION H,
FOR MOUNTING
SPECIFICATIONS
SEE
Maintenance and
Office Building
Mechanical and
Electrical Building
DESIGNATOR
2", TYP. OF ROOM
TEXT SIZE:
DESIGNATOR
BUILDING
3", TYP OF
TEXT SIZE:
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
DIAMETER
SHEET NOTES:
FOR CONCRETE FOOTING REQUIREMENTS.
PLACE STRUCTURAL CONCRETE FOR CIVIL WORKS"
SEE SPECIFICATION SECTION 03 31 01.00 25 "CAST-IN-6.
TYPEFACE.
SIGNAGE", PARAGRAPH 2.1.2.2 FOR REQUIRED TEXT
SEE SPECIFICATION SECTION 10 14 00.10 28 "EXTERIOR 5.
LOCATIONS
SEE SHEET CS105 FOR EXTERIOR SIGNAGE PLACEMENT 4.
SIGNAGE" FOR SIGNAGE SCHEDULE REQUIREMENTS.
SEE SPECIFICATION SECTION 10 14 00.10 28 "EXTERIOR 3.
DETAILS, THIS SHEET.
MOUNT EXTERIOR SIGNS IN CONCRETE FOOTINGS PER 2.
ULTRAVIOLET RESISTANT
MATERIALS THAT ARE BOTH WEATHER AND
FABRICATE EXTERIOR SIGNAGE WITH NON-FERROUS 1.
SIGN ELEVATION SECTION A SECTION B
A
B
ROOM DESIGNATORS BUILDING DESIGNATORS
DETAIL: BUILDING SIGN INSTALL
SCALE: 1"=1'-0"-
DETAIL: FACILITY SIGN INSTALL
SCALE: 1"=1'-0"-
FACILITY SIGNAGE GRAPHICS
SCALE: 1-1/2"=1'-0"-
BUILDING SIGNAGE GRAPHICS
SCALE: 1-1/2"=1'-0"-
B
SIGN ELEVATION SECTION A SECTION B
A
0 1' 2'6"
0 1' 2'6"
1' 2'0 6"
1' 2'0 6"
6'-5"
6'-0"
3'-0"
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
/0
/2
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
P P
P L
A N
S S
E C
T
IO
N
I S
O M
E T
R
IC
S H
A D
E S
T R
U C
T U
R E
F
IS
H L
A D
D E
R
A W
S D
IF
F
U S
IO
N
C H
A M
B E
R
AK101
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
D X
F .1
A
K .d g n
B C
O E
S R
E V
IE
W
1' 0" 2' 0" 4' 0"0
1' 0" 2' 0" 4' 0"0 1' 0" 2' 0" 4' 0"0
2:12 SLOPE
9 6
C L
CL
TOS
EL 663.83'
2% SLOPE
TOP OF CURB
EL 664.5'
C L
DRAWING PLOT SIZE: $BORDER$
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
BORDER VERSION UPDATE [12-2015]
$SHEETN$SHEET NAME:$USER$BY USERNAME:DATE AND TIME PLOTTED: $$$DATE$$$$ $TIME
D
A T
E
KEY NOTES:
KEY NOTE
FROM THE EQUIPMENT AS SHOWN
PRECAST CONCRETE SPLASH BLOCK, DIRECT WATER AWAY
SHEET METAL HIGH SIDE TRIM
SHEET METAL TRIM AT RAKE, TYPICAL
CONTRACTOR DESIGN, 6" THICK MINIMUM
REINFORCED CONCRETE SLAB AND COLUMN FOOTING PER
ROOF PURLINS PER PEMB MANUFACTURER
MANUFACTURER, TYPICAL OF 2
TUBE STEEL MOMENT COLUMN AND BEAM PER PEMB
BEAM PER PEMB MANUFACTURER
MOMENT CONNECTION PLATE BETWEEN COLUMN AND ROOF
OVERHEAD ROOSTING
BIRD NETTING, PROVIDE FULL COVERAGE TO EXCLUDE ALL
CONCRETE CURB
ELECTRICAL EQUIPMENT CABINETS, SEE ELECTRICAL
CONCRETE SPLASH BLOCK, SEE AZ502.
OPEN FACE SHEET METAL DOWNSPOUT, DISCHARGE TO
SHEET NOTES:
2.
1.
PROVIDE LEVELING GROUT UNDER BASEPLATE
CONCRETE SLAB WITH REMOVABLE NUTS AND WASHERS,
COLUMN BASE PLATE PER PEMB MANUFACTURER, BOLT TO
METAL ROOF PANELS
WHERE OCCURS
BIRD DETERRENT SPIKES AT TOP OF COLUMN LEDGE,
N
GRADING
SEE CIVIL SHEET CG101 FOR INFORMATION ON SITE
GENERAL NOTES
SEE SHEET A-001 FOR ABBREVIATIONS, SYMBOLS, AND
ELECTRICAL CLEARANCE AREA18
GUARDRAIL, SEE STRUCTURAL19
N
DOWNSPOUT
SHEET METAL GUTTER, SLOPE 1/8" PER FOOT TOWARDS
FINISH GRADE PER CIVIL
SEE DETAIL 10 ON SHEET AY503
EMBEDDED PIPE BOLLARD, TYPICAL
C
FINISH NOTES:
SUBMITTAL PROCESS.
MANUFACTURER STANDARD OFFERINGS AS PART OF THE
SELECTION WILL BE MADE BY THE GOVERNMENT FROM
COLORS PROVIDED ARE GENERAL INTENT. FINAL COLOR 1.
A-001
B
SCALE: 1/2" = 1'-0"
FLOOR PLAN
A-001
A
SCALE: 1/2" = 1'-0"
ROOF PLAN
C
SCALE: NTS
ISOMETRIC
D
SCALE: 1/2" = 1'-0"
CROSS SECTION
D DRAFT
-0
18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"
36'-0"90'-0"
5'-4"
SHADE STRUCTURE ROOF FUTURE SHADE STRUCTURE ROOF EXPANSION
O
V E
R H
A N
G O
V E
R H
A N
G
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
/0
/2
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T T
H E
W G
Z A
N G
E R
R
A
A R
C H
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
P P
R O
O F
A N
D F
L O
O R
P L
A N
S S
H A
D E
S T
R U
C T
U R
E
P R
E -S
O R
T P
O O
L
AL101
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
B C
O E
S R
E V
IE
W
D X
F .1
A
L .d g n
A C L
CL
CL
CL
CL
CL
CL
CL
CL
1.1
B C L
FACE OF
CONC
7 7 7
7 7 7
F O
C
FACE OF
COLUMN
FACE OF
COLUMN
FACE OF
CONC
SHEET NOTES:
SEE MECHANICAL FOR EQUIPMENT ASSOCIATED WITH THE PRE-SORT POOL.
SEE STRUCTURAL FOR WALKWAYS, STAIRS AND CONCRETE ASSOCIATED WITH THE PRE-SORT POOL.
SEE SHEET AL301 AND AL 601 FOR METAL SUN LOUVERS.
SHADE STRUCTURE ROOF EXPANSION (GRID LINES 7 AND 8).
FOUR CONCRETE FOOTINGS AND PEDESTALS ARE TO BE INSTALLED IN PREPARATION FOR POSSIBLE FUTURE
CONDITIONS, I.E. ON SOIL AND ON ROCK
OF ROCK LAYER; FOUNDATION DESIGN BY PEMB MANUFACTURER MUST ACCOUNT FOR DIFFERENT BEARING
SUBSURFACE ROCK CONDITIONS VARY; SEE CIVIL SHEETS FOR SITE SECTIONS INDICATING ESTIMATED DEPTH
SEE SHEET C-100 FOR INFORMATION ON SITE GRADING
SEE SHEET A-001 FOR ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES
KEY NOTES:
KEY NOTE
MANUFACTURER, TYPICAL OF 15
CONC FOOTINGS AND PEDESTALS, PER PEMB
METAL ROOF PANELS
SHEET METAL GUTTER, NO SLOPE, TYPICAL OF 2
PRECAST CONCRETE SPLASH BLOCK AT DISCHARGE
OPEN FACE SHEET METAL DOWNSPOUT WITH
NOT IN USE
VENTED SHEET METAL RIDGE CAP
FLUME TO SORT AREA - SEE MECHANICAL
SHEET METAL TRIM AT RAKE, TYPICAL
TYPICAL OF 6
MOMENT FRAME PER PEMB MANUFACTURER,
VAULT, SEE MECHANICAL
NOT IN USE
EXPANSION JOINT IN GUTTER
NOT IN USE
EXPANSION
FOOTING AND PEDESTAL FOR FUTURE SHADE STRUCTURE
SEE MECHANICAL
APPROXIMATE LOCATION OF FISH WATER SUPPLY PIPE BELOW FOOTING,
FISH WATER SUPPLY PIPE TRENCH BELOW, PER PEMB MANUFACTURER
SPECIALTY CONC FOOTING AND PEDESTAL, SIZE FOOTING TO SPAN ACROSS
PRE-SORT POOL - SEE STRUCTURAL
STRUCTURAL
STEEL WALKWAY AND ACCESS STAIRS - SEE
SHEET
SF101
SHEET
SF101
AZ502
MP506
PIPING BELOW GRADE, TYPICAL - SEE MECHANICAL
MANUFACTURER
DIAGONAL LATERAL BRACING PER PEMB
0 4' 8' 12'
0 4' 8' 12'
N N
7.
6.
5.
4.
3.
2.
1.
NOTE
A-001
A
SCALE: 3/16" = 1'-0"
ROOF PLAN
A-001
B
SCALE: 3/16" = 1'-0"
FLOOR PLAN
AL301
A
AL301
B
AL301
C
CL
CL
CL
CL
CL
CL
CL
CL
C L
B C L
5 3
A
BELOW
LINE
RIDGE
18 18
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
2DRAFT
FUTURE SHADES STRUCTURAL EXPANSION
M
IN
C
L E
A R
13'-8" MIN CLEAR
T Y
P
IC
A L
A T
E A
C H
B A
Y
L
O U
V E
R A
S S
E M
B L
Y
12'-9" 12'-9"
25'-6"
6'-3"13'-0"6'-3"
O P
E N
IN
G
M
S
E S
T R
S H
E E
T
25'-6"
8" OVERHANG 8" OVERHANG
CLEAR
MIN
4'-0"
C L
E A
R
T Y
P
M
IN
CLEAR
MIN
4'-0"
13'-0"
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
/0
/2
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
P P
P R
E -S
O R
T P
O O
L
AL301
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
B C
O E
S R
E V
IE
W
D X
F .1
A
L .d g n
S E
C T
IO
N
S
I S
O M
E T
R
IC
S H
A D
E S
T R
U C
T U
R E
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
CL
CL
CL
CL
CL
CL
TOC
EL 677.50'
1.1
F O
C 1
TOC
EL 677.08'
BA
PEDESTAL, TYP
TOP OF CONC
EL 670.57'
SECTION
LONGITUDINAL
VARIES, SEE
AT SPRINGPOINT
TOP OF COLUMN
EL 697.08'
TOP OF MOMENT FRAME
EL 669.33'
TOP OF WALKWAY
SEE STRUCTURAL
TOP OF WALKWAY
SEE STRUCTURAL
SEE CIVIL
FINISH GRADE
EL VARIES
0 4' 8' 12'
0 4' 8' 12'
KEY NOTES:
KEY NOTE
DIAGONAL LATERAL BRACING PER PEMB MANUFACTURER
SHEET METAL ROOF PANELS
SHEET METAL GUTTER, NO SLOPE, TYPICAL OF 2
BLOCK, TYPICAL OF 8, SEE AZ502
OPEN FACE SHEETMETAL DOWNSPOUT WITH PRECAST CONCRETE SPLASH
CROWDER ASSEMBLY PER MECHANICAL
SHEET METAL VENTED RIDGE CAP
PEMB MANUFACTURER
SECONDARY STRUCTURAL SUBFRAMES TO SUPPORT SUN LOUVERS PER
SHEET METAL TRIM AT RAKE, TYPICAL
MOMENT FRAME PER PEMB MANUFACTURER, TYPICAL OF 6 FISH LADDER PER STRUCTURAL
NOT IN USE
NOT IN USE
THAN 6'-0" ABOVE ADJACENT FINISH GRADE, TYPICAL AT ALL PEDESTALS
TOP OF CONTRACTOR DESIGNED CONC PEDESTALS MUST NOT BE HIGHER
PIPING BELOW GRADE - SEE MECHANICAL
PRE-SORT POOL - SEE STRUCTURAL
STEEL WALKWAY AND ACCESS STAIRS - SEE STRUCTURAL
CONCRETE FOOTINGS AND PEDESTALS CONTRACTOR DESIGN, TYPICAL OF 16
METAL SUN LOUVERS, SEE SCHEDULE ON AL601
ROOF PURLINS PER PEMB MANUFACTER, TYPICAL
ROOSTING
BIRD NETTING, PROVIDE FULL COVERAGE TO EXCLUDE ALL OVERHEAD
SHEET NOTES:
SORT POOL.
SEE MECHANICAL FOR EQUIPMENT AND PIPING ASSOCIATED WITH THE PRE-
WITH THE PRE-SORT POOL.
SEE STRUCTURAL FOR WALKWAYS, STAIRS, AND CONCRETE ASSOCIATED
SECTIONS INDICATING ESTIMATED DEPTH OF ROCK LAYER.
SUBSURFACE ROCK CONDITIONS VARY. SEE CIVIL SHEETS FOR SITE
SEE SHEET CS101 FOR INFORMATION ON SITE GRADING
SEE SHEET A-001 FOR ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES
5.
4.
3.
2.
1.
AL501
AL501
AL101
A
SCALE: 3/16" = 1'-0"
LONGITUDINAL SECTION
AL101
B
SCALE: 3/16" = 1'-0"
CROSS SECTION
AL101
C
NOT TO SCALE
ISOMETRICDRAFT
STRUCTURE MANUFACTURER.
REQUIRED BY THE PRE-ENGINEERED CANOPY
LOUVERS - WIDTH SHALL BE 6" X DEPTH AS
STRUCTURAL HORIZONTAL TS SUPPORT FOR
1" 4"
THE STEEL STRUCTURAL SUPPORT FRAME.
TAPE TO ISOLATE THE ALUMINUM LOUVER FROM
SELF-ADHERING PVC CORROSION PROTECTION
SIDE OF THE LOUVER FRAME.
CONTINUOUS SILICONE SEALANT TO EACH
TO MEET THE WIND LOADING CRITERIA .
SPACED AS REQUIRED BY THE LOUVER MFR.
WITH 1/4" DIAMETER SELF-DRILLING FASTENERS
SHIMS AND FASTEN TO THE TS SUPPORT FRAME
(SEE SPEC). CENTER IN OPENING WITH PLASTIC
FIXED, DRAINABLE BLADE SUNSCREEN LOUVER
THE STEEL STRUCTURAL SUPPORT FRAME.
TAPE TO ISOLATE THE ALUMINUM LOUVER FROM
SELF-ADHERING PVC CORROSION PROTECTION
SIDE OF THE LOUVER FRAME.
CONTINUOUS SILICONE SEALANT TO EACH
STRUCTURE MANUFACTURER.
REQUIRED BY THE PRE-ENGINEERED CANOPY
LOUVERS - WIDTH SHALL BE 6" X DEPTH AS
STRUCTURAL HORIZONTAL TS SUPPORT FOR
TO MEET THE WIND LOADING CRITERIA .
SPACED AS REQUIRED BY THE LOUVER MFR.
WITH 1/4" DIAMETER SELF-DRILLING FASTENERS
SHIMS AND FASTEN TO THE TS SUPPORT FRAME
(SEE SPEC). CENTER IN OPENING WITH PLASTIC
FIXED, DRAINABLE BLADE SUNSCREEN LOUVER
MEET THE WIND LOADING CRITERIA .
FASTENERS SPACED AS REQUIRED BY THE LOUVER MFR. TO
THE TS SUPPORT FRAME WITH 1/4" DIAMETER SELF-DRILLING
CENTER IN OPENING WITH PLASTIC SHIMS AND FASTEN TO
FIXED, DRAINABLE BLADE SUNSCREEN LOUVER (SEE SPEC).
CANOPY STRUCTURE MANUFACTURER.
SHALL BE 6" X WIDTH AS REQUIRED BY THE PRE-ENGINEERED
STRUCTURAL VERTICAL TS SUPPORT FOR LOUVERS - DEPTH
SIDE OF THE LOUVER FRAME.
CONTINUOUS SILICONE SEALANT TO EACH
THE STEEL STRUCTURAL SUPPORT FRAME.
TAPE TO ISOLATE THE ALUMINUM LOUVER FROM
SELF-ADHERING PVC CORROSION PROTECTION
LOUVER JAMB FRAMES TOGETHER.
LOUVER MULLIONS FORMED BY FASTENING
CONTINUOUS SILICONE SELANT.
JAMB FRAMES WITH BACKER ROD AND
SEAL THE OUTSIDE JOINT BETWEEN LOUVER
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
B P
IC
K
L E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
P P
D E
T A
IL
S
S H
A D
E S
T R
U C
T U
R E
P R
E -S
O R
T P
O O
L
AL501
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
/0
/2
B C
O E
S R
E V
IE
W
D X
F .1
A
L .d g n
OUTSIDE
OUTSIDE
OUTSIDE
DRAWING PLOT SIZE: $BORDER$
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
BORDER VERSION UPDATE [12-2015]
$SHEETN$SHEET NAME:$USER$BY USERNAME:DATE AND TIME PLOTTED: $$$DATE$$$$ $TIME
D
A T
E
HEAD DETAIL: SUNSCREEN LOUVER
SCALE: 3"=1'-0"-
SILL DETAIL: SUNSCREEN LOUVER
SCALE: 3"=1'-0"-
JAMB/MULLION DETAIL: SUNSCREEN LOUVER
SCALE: 3"=1'-0"-
6"0 3" 1'
6"0 3" 1'
6"0 3" 1'
18'-0" MAX (CENTER TO CENTER OF COLUMNS)
EQUAL EQUAL EQUAL
Q U
L
Q U
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
P P
S C
H E
D U
L E
S S
H A
D E
S T
R U
C T
U R
E
P R
E -S
O R
T P
O O
L
AL601
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
/0
/2
B C
O E
S R
E V
IE
W
D X
F .1
A
L .d g n
LV-1
LOUVER ASSEMBLY
LV-1 LV-1 LV-1
LV-1LV-1LV-1
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
LOUVER NOTES:
MANUFACTURER
MOUNT LOUVERS TO OUTSIDE OF MOMENT FRAME COLUMNS PER PEMB
SEE SHEET AL301 FOR MOUNTING HEIGHT.
BAY AS SHOWN ON AL301, TYPICAL OF 10 LOUVER ASSEMBLIES.
PROVIDE LOUVER ASSEMBLIES ON BOTH SIDES OF THE MOMENT FRAMES AT EACH
KEY NOTES:
ID KEYNOTE
ON PEMB DESIGN OF SUBFRAMING MEMBERS TO MAINTAIN OVERALL ASSEMBLY DIMENSIONS
LOUVER SIZES ARE APPROXIMATE FOR BIDDING PURPOSES, ACTUAL SIZE TO BE ADJUSTED BASED
HSS LOUVER SUBFRAME, SIZING PER PEMB MANUFACTURER
3.
2.
1.
FINISH NOTES:
SUBMITTAL PROCESS.
MANUFACTURER STANDARD OFFERINGS AS PART OF THE
SELECTION WILL BE MADE BY THE GOVERNMENT FROM
COLORS PROVIDED ARE GENERAL INTENT. FINAL COLOR 1.DRAFT
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
P P
IS
O
M E
T R
IC
S
S H
A D
E S
T R
U C
T U
R E
S O
R T
IN
G
F A
C
IL
IT
Y
AM901
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
D X
F
.1
A M
.d g n
/0
/2
B C
O E
S R
E V
IE
W
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
SW ISOMETRIC
NOT TO SCALEAM101
A
NE ISOMETRICB
AM101 NOT TO SCALE
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
/0
/2
B C
O E
S R
E V
IE
W
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
IF
E
S A
F E
T Y
A
C C
E S
S
IB
IL
IT
Y
C
O D
E
M A
IN
T
E N
A N
C E
O
F F
IC
E
B U
IL
D
IN
G
AY001
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
D X
F .1
A
Y .d g n
L5
CCC
L6 L5
C
FEC
MAINTENANCE BAY
OFFICE
RESTROOM
CORRIDOR
FEC
F E
C
HW
MS
EES
ROOM
CONFERENCE
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
FEC
MAINTENANCE BAY
OFFICE
RESTROOM
CORRIDOR
FEC
F E
C
HW
MS
EES
ROOM
CONFERENCE
ELECTRICAL SHEETS.
IS SHOWN ON MECHANICAL AND
INFORMATION PERTAINING TO EQUIPMENT
EGRESS PATHS ONLY.
FOR THE PURPOSED OF CALCULATING
FURNISHINGS AND VEHICLES ARE SHOWN
FIRE EXTINGUISHER CABINET MOUNTING.
SEE INTERIOR ELEVATIONS ON AY401 FOR
LIGHTING AND EXIT SIGN INFORMATION.
SEE ELECTRICAL FOR EMERGENCY
CONSTRUCTION DOCUMENTS.
CONTAINED HERE IS LOCATED WITHIN THE
CONTRACT AND ALL INFORMATION
IS NOT PART OF THE CONSTRUCTION
THIS SHEET IS FOR REFERENCE ONLY. IT
CODE DATA:
4' 8'0 2'
N
5.
4.
3.
2.
1.
SHEET NOTES:
LEGEND
PARTITION
SMOKE
DISTANCE
TRAVEL
MAXIMUM
ELECTRICAL
LIGHTING PER
EMERGENCY
EXIT SIGN WITH
ILLUMINATED
FEC
CABINET
FIRE EXTINGUISHER
CLEARANCE AREA
ACCESSIBILITY
4' 8'0 2'
N
C
LOCATION
EXIT
BUILDING
ELECTRICAL
FIXTURE PER
LIGHTING
EMERGENCY
A-001
A Full Size 1/4" = 1'-0"
CODE PLAN
A-001
B Full Size 1/4" = 1'-0"
ACCESSIBILITY CLEARANCES PLAN
55'-8"
19'-4"19'-4" 17'-0"
"2
2'-1
R
O
"6
55'-4" OUT TO OUT OF 8" WALL GIRTS
3'-1"
5'-4"
2'-9"+/-
O
U T
T O
O U
T O
F
W
A L
L G
IR
T
S
24'-0" ROUGH OPENING"2
4'-1"2
5'-3 4'-0"3'-6" RO
17'-0" FACE OF GIRT TO FACE OF STUD WALL
8" WALL GIRT, TYP
R
O
R
O
R
O
1'-10"
1'-2"
4'-2"
4'-6" MIN 2'-2"+/-
10'-6"
8"
F
IN
C
L R
M
IN
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
/0
/2
B C
O E
S R
E V
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
R
O O
F F
L O
O R
E N
L A
R G
E D
P L
A N
S
M A
IN
T
E N
A N
C E
O
F F
IC
E
B U
IL
D
IN
G
AY101
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
D X
F .1
A
Y .d g n
27 2727
2:12 SLOPE2:12 SLOPE2:12 SLOPE
E A
V E
E A
V E
R
ID
G E
L
IN
E
L
IN
E
A
C
GIRT
FACE OF
GIRT
FACE OF
LINE
RAKE
LINE
RAKE
L
IN
E
E A
V E
L
IN
E
W1 W2
W2
W2
W1
W4
W3
AY102
AY101
AY105C
W5
W5
AY105A AY105B
AY103
AY104
MAINTENANCE BAY
A
C
OFFICE
RESTROOM
CONFERENCE
ROOM
CORRIDOR
A
A
A
A
A
B
D W
C L
AY401 D
E
FAY401
LC
LC
LC
LC
CL
C L C L
FACE OF GIRT
O F
G
IR
T
F A
C
G
IR
T
F A
C E
F
FACE OF GIRT
F
G
IR
T
F A
CL
FACE OF GIRT
FACE OF GIRT
F A
C E
O F
G
IR
T
CL
W2
W3
W2
W1
C L
CL
36 36
C L C L
AY503
9&10
AY502
13&14
AY502
5&6
AY502
D
C
AY503
AY503
AY502
AY502
AY301
D
AY201
D
AY201
A
AY301
C
AY201
B
AY301
B
AY201
C
AY301
A
AY301
E
W5
A Q
W5
RESTROOM
A
C
B
C L
W2
W4
W4
W4
G
IR
T
S
AY103
AQ401
CONFERENCE
ROOM
W3
~GIRTS~
W2
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
KEY NOTES:
SECURE TO STRUCTURE WITH SEISMIC BRACING
HOT WATER TANK - SEE PLUMBING PLAN
KEY NOTE KEY NOTE
SINGLE PIECE TWO-WALL GRAB BAR - SEE SHEETS AY301 AND AY401
SANITARY NAPKIN DISPOSAL
DISCHARGE, TYPICAL OF 4 - SEE SHEET AZ502
CONNECT TO UNDERGROUND STORM WATER PIPING AT DOWNSPOUT
TOILET TISSUE DISPENSER
SOAP DISPENSER
TRENCH DRAIN - SEE PLUMBING PLAN
SEMI-RECESSED FIRE EXTINGUISHER CABINET
EMERGENCY EYE WASH STATION - SEE PLUMBING PLAN
ELECTRICAL/TELECOM EQUIPMENT - SEE ELECTRICAL
MOP SINK AND FAUCET - SEE PLUMBING PLAN
INSULATED METAL PANELS, CONFORM AROUND GIRTS AS NECESSARY
CONTINUE WALL AND BATT INSULATION TIGHT TO BACKSIDE OF
WATER CLOSET - SEE PLUMBING PLAN
LAVATORY AND FAUCET - SEE SECTION 12 32 00 AND PLUMBING PLAN
NOT IN USE
DIAGONAL BRACING FOR MOMENT FRAME PER PEMB MANUFACTURER
MOMENT FRAME PER PEMB MANUFACTURER
MIRROR 24" X 36" - SEE SHEET AY401
ON AY301 AND AY401
UPPER WALL CABINETS - SEE INTERIOR ELEVATIONS AND SECTIONS
ELEVATIONS AND SECTIONS ON AY301 AND AY401
BASE CABINETS WITH COUNTERTOP AND BACKSPLASH - SEE INTERIOR
AND PLUMBING PLAN
KITCHEN SINK, FAUCET, AND HANDSPRAY HOSE - SEE SECTION 12 32 00
PAPER TOWEL DISPENSER
COMBINATION COAT HOOK AND BUMPER
FUTURE REFRIGERATOR LOCATION - NOT IN CONTRACT
PROVIDE HOOKUPS - SEE MECHANICAL & ELECTRICAL
FUTURE WASHER & DRYER APPLIANCES, NOT IN CONTRACT.
TRANSITION STRIP BETWEEN FLOORING
MINIMUM, TYPICAL OF 6, SEE SHEET AZ502
OPEN FACE RECTANGULAR SHEET METAL DOWNSPOUT, 3 1/2" X 4"
INSULATED METAL ROOF PANELS
SHEET METAL GUTTER, 4" X 4" MINIMUM, NO SLOPE, TYPICAL OF 3
NOT IN USE
DRYER EXHAUST VENT HOOD - SEE MECHANICAL
SHEET METAL RIDGE CAP
VINYL PLANK FLOORING - SEE SHEDULE ON SHEET AY602
MAXIMUM - SEE SHEDULE ON SHEET AY602
TILE FLOORING - CENTER ON FLOOR DRAIN AND SLOPE TO DRAIN 2%
SHEET AY102
SLOPED CONCRETE FLOOR, STEEL TROWEL FINISH - SEE SLAB PLAN ON
SURFACE-MOUNTED PIPE BOLLARD - SEE SHEET AY503
CONCRETE ROAD AND SIDEWALK - SEE CIVIL
EMBEDDED PIPE BOLLARD - SEE SHEET AY503
PLUMBING PLAN FOR VENT PIPE
WASTE VENT TERMINATION WITH SILICONE FLASHING BOOT - SEE
DAMPER - SEE MECHANICAL
LOUVER - SEE LOUVER SCHEDULE ON SHEET AY601
SHEET NOTES:
SEE SHEET AY603 FOR SIGN SCHEDULE5.
SEE SHEET AY602 FOR FINISHES SCHEDULES4.
SEE SHEET AY601 FOR DOOR, WINDOW, LOUVER, AND WALL SCHEDULES3.
SEE SHEET AY102 FOR THE REFLECTED CEILING PLAN AND CONCRETE SLAB PLAN2.
SEE SHEET A-001 FOR ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES1.
N
N
N N
4' 8'0 2'
4' 8'0 2'
2' 4'0 1'2' 4'0 1'
A-001
A
SCALE: 1/4" = 1'-0"
ROOF PLAN
A-001
B
SCALE: 1/4" = 1'-0"
FLOOR PLAN
C
SCALE: 1/2" = 1'-0"
PARTIAL ENLARGED FLOOR PLAN
ROOM 103
D
SCALE: 1/2" = 1'-0"
PARTIAL ENLARGED FLOOR PLAN
ROOM 104
27'-9"+/- FROM FACE OF COLUMN TO CENTERLINE OF HOIST BEAM
6"
6"
55'-4"
37'-2" APPROXIMATELY, COORDINATE WITH PEMB COLUMN LAYOUT
16'-0"EQUAL EQUAL
24'-6"+/- ROUGH OPENING, COORDINATE WITH DOOR FRAMING2'-2""2
3'-4"2
3'-7
10'-8"
2'-0"+/-
"2
3'-4 13'-1"
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
/0
/2
D X
F .1
A
Y .d g n
AY102
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
F
L E
C T
E D
C E
IL
IN
G P
L A
N
S L
A B
P L
A N
M A
IN
T
E N
A N
C E
O
F F
IC
E
B U
IL
D
IN
G
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
B C
O E
S R
E V
IE
W
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
9'-0"
9'-0"
9'-0"
RESTROOM
ROOM
CONFERENCE
HALLWAY
MAINTENANCE BAY
OFFICE
9'-0"
EXPOSED
C L
16 16
161612
12 12
2% SLOPE 2% SLOPE
S L
O P
E S
L O
P E
TOS
EL 659.00'
TOW
EL 659.50'
T O
W
E L
.5
T O
W
E L
.5
TOW
EL 661.50'
TOP OF GRATING
EL 658.79'
TOS
EL 659.00'
TOS
EL 659.00'
T O
W
E L
.5
T O
W
E L
.5
T O
W
E L
.5
T O
W
E L
.5
TOW
EL 659.50'
TOS
EL 659.00'
TOS
EL 659.00'
TOS
EL 658.83'
T O
S
E L
.0
TOS
EL 659.00'
FACE OF
FOUNDATION
F A
C E
O F
F O
U N
D A
T
IO
N
E D
G E
O F
F O
U N
D A
T
IO
N
FACE OF
FOUNDATION
V A L L E
Y
V A L L E
Y V
A L L E
Y
V A L L E
Y
2 2 2
C L
KEY NOTE
HOIST BEAM PER PEMB MANUFACTURER
NOT IN USE
INSULATED METAL ROOF PANELS, EXPOSED UNDERSIDE
SHEET NOTES:
6.
5.
4.
3.
2.
1.
LEGEND:
PURLINS PER PEMB MANUFACTURER, TYPICAL
DIAGONAL LATERAL BRACING PER PEMB MANUFACTURER
MOMENT FRAME PER PEMB MANUFACTURER
COILING OVERHEAD DOOR HOOD PER DOOR SCHEDULE - SEE SHEET AY601
TRENCH DRAIN - SEE PLUMBING PLAN
CONTROL JOINTS PER PEMB MANUFACTURER SLAB DESIGN
NOT IN USE
FLOOR DRAIN - SEE PLUMBING PLAN
9'-0"
SUSPENDED ACOUSTIC CEILING TILE (2'X2')
GYPSUM BOARD CEILING (PAINTED)
DENOTES CEILING HEIGHT FROM FINISH FLOOR
EXPOSED
UNDERSIDE OF INSULATED METAL ROOF PANELS)
DENOTES EXPOSED STRUCTURE (PURLINS, MOMENT FRAME, AND
2' X 2' RECESSED LIGHT FIXTURE, SEE EY101
LIGHT FIXTURE, SEE EY101
SUSPENDED MAINTENANCE BAY
EXHAUST FAN IN CEILING, SEE MY101
TRANSFER RETURN GRILLE, SEE MY101
SUPPLY DIFFUSER, SEE MY101
SEE ROOM FINISH SCHEDULE ON AY602 FOR ADDITIONAL INFORMATION.
SLAB TO HAVE UNDER SLAB VAPOR BARRIER OVER 8" MIN COMPACTED GRAVEL BASE.
FOR SPECIFIC INFORMATION ON COMPONENTS AND SYSTEMS.
COORDINATION AND LOCATION PURPOSES ONLY. SEE MECHANICAL AND ELECTRICAL DRAWINGS
MECHANICAL AND ELECTRICAL INFORMATION SHOWN ON ARCHITECTURAL DRAWINGS IS FOR
SEE MECHANICAL FOR ADDITIONAL INFORMATION - MY101
SEE ELECTRICAL FOR ADDITIONAL INFORMATION - EY402
SEE SHEET A-001 FOR ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES
N
N
EXTERIOR LIGHT FIXTURE - SEE ELECTRICAL
EMERGENCY LIGHT FIXTURE - SEE ELECTRICAL
EXIT SIGN AND EMERGENCY LIGHT - SEE ELECTRICAL
HIGH BAY LIGHT FIXTURE, TYP - SEE ELECTRICAL
VENTED SHEET METAL SOFFIT, TYPICAL AT OVERHANGS
EXHAUST FAN, DAMPER AND WEATHER HOOD - SEE MECHANICAL
RESTROOM SLAB
PROVIDE CONTROL JOINTS AROUND THE PERIMETER OF THE RECESSED
STEP IN CONCRETE STEM WALL
4' 8'0 2'
4' 8'0 2'
KEY NOTES:
AY101
B
SCALE: 1/4" = 1'-0"
SLAB PLAN
AY101
A
SCALE: 1/4" = 1'-0"
REFLECTED CEILING PLAN
H
E A
D T
Y P
EQUAL
R
O U
G H
O P
E N
IN
G
EQUAL
G R
A D
E F
IN
IS
H A
B O
V E
1'-4"
1'-6" +/-
H
E A
D T
Y P
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
/0
/2
B C
O E
S R
E V
IE
W
D X
F .1
A
Y .d g
AY201
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
T
E R
IO
R
E L
E V
A T
IO
N
S
I S
O M
E T
R
IC
M A
IN
T
E N
A N
C E
O
F F
IC
E
B U
IL
D
IN
G
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
DRAWING PLOT SIZE: $BORDER$
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
BORDER VERSION UPDATE [12-2015]
$SHEETN$SHEET NAME:$USER$BY USERNAME:DATE AND TIME PLOTTED: $$$DATE$$$$ $TIME
D
A T
E
16 18
EL 659.00 = TOS
CENTER
OVER DOOR
12 12
LV3
A
A
AY101AY105A
Maintenance and
Office Building
1111 17
2+/-:1
2 SLOPE
2+/-:1
2 SLOPE
2+/-:12 SLOPE
C L
C L
EL 659.00 = TOS
FG = 661.00 +/-
6 ~
LV1
TOS EL 659.00
LV2
1 3
EL 659.00 = TOS
A A A A
KEY NOTE
INSULATED METAL ROOF PANELS - SEE SHEET AY501
SHEET METAL GUTTER, NO SLOPE, TYPICAL OF 3 - SEE SHEET AY501
NOT IN USE
SHEET METAL RIDGE CAP - SEE SHEET AY501
INSULATED METAL WALL PANELS - SEE SHEET AY501 AND AY502
SHEET METAL TRIM AT RAKE - SEE SHEET AY501
CONCRETE ROAD AND SIDEWALK - SEE CIVIL
SHEET METAL TRIM AT OUTSIDE CORNER
FOUNDATION BELOW, DESIGN PER CONTRACTOR
WINDOW - SEE SHEETS AY502 AND AY601
EXHAUST FAN, DAMPER AND WEATHERHOOD - SEE MECHANICAL
COILING OVERHEAD DOOR - SEE SHEETS AY502 AND AY601
FOUNDATION INSULATION WITH PROTECTIVE COATING - SEE SHEET AY501
PLUMBING PLAN
WASTE VENT TERMINATION WITH SILICONE FLASHING BOOT - SEE
DAMPER - SEE MECHANICAL
LOUVER - SEE SHEETS AY503 AND AY601
PERSONNEL DOOR - SEE SHEETS AY502 AND AY601
SHEET METAL TRIM AT WINDOWS, DOORS, AND LOUVERS
VENTED SHEET METAL SOFFIT, TYPICAL AT OVERHANGS - SEE SHEET AY501
30 NOT IN USE
NOT IN USE
NOT IN USE
NOT IN USE
NOT IN USE
FINAL PLACEMENT IN THE FIELD - SEE SHEET A-601
BUILDING SIGN, LOCATION SHOWN REFLECTS DESIGN INTENT, COORDINATE
DISCHARGE, TYPICAL OF 4 - SEE SHEET AZ502
CONNECTION TO UNDERGROUND STORM DRAINAGE SYSTEM AT DOWNSPOUT
EMBEDDED PIPE BOLLARD - SEE SHEET AY503
DRYER EXHAUST VENT HOOD - SEE MECHANICAL
EXTERIOR LIGHT FIXTURE - SEE ELECTRICAL
TYPICAL OF 6 - SEE SHEET AY503
OPEN FACE RECTANGULAR SHEET METAL DOWNSPOUT, 3 1/2" X 4" MINIMUM,
EAST ELEVATION
SCALE: 1/4" = 1'-0"AY101
B 4' 8'0 2'
SOUTH ELEVATION
SCALE: 1/4" = 1'-0"AY101
A 4' 8'0 2'
WEST ELEVATION
SCALE: 1/4" = 1'-0"AY101
D 4' 8'0 2'
NORTH ELEVATION
SCALE: 1/4" = 1'-0"AY101
C 4' 8'0 2'
ISOMETRIC
NOT TO SCALE
E
KEY KEYNOTE NOTE
NOT IN USE
KEY NOTES:DRAFT
A B
A
B O
V
H
E A
D T
Y P
T O
B O
T T
O M
O F
H O
IS
T
B E
A M
/2
T
Y P
IC
A
L
AY101
SEE
AY101
SEE
T
Y P
IC
A
L
CLEAR
MIN FIN
3'-4"
1'-6"
3'-6"
3'-0" 3'-0" 3'-0"
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
/0
/2
B C
O E
S R
E V
IE
W
D X
F .1
A
Y .d g
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
C
T
IO
N S
M A
IN
T
E N
A N
C E
O
F F
IC
E
B U
IL
D
IN
G
AY301
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
AC B
4849 LV2
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
2+/-:1
2 SLOPE
2+/-:1
2 SLOPE 2+/-:12 SLOPE
13 2 2
EL 659.00
TOS
8 89
TOP OF BEAM
AT SPRING POINT
TOP OF COLUMN
AT SPRING POINT
TOP OF COLUMN
TOP OF RIDGE
AY105B
AY105AAY101
1 32
49 LV1
22 22
A CB
AY105C
AC B
CL
C L27
51 44 35
AY102
AY103
INSULATED METAL ROOF PANELS
SHEET METAL GUTTER, TYPICAL OF 3 - SEE AY501
AND AY201
OPEN FACE SHEET METAL DOWNSPOUT, TYPICAL OF 6 - SEE AY101
SHEET METAL RIDGE CAP - SEE AY501
INSULATED METAL WALL PANELS
SHEET METAL TRIM AT RAKE - SEE AY501
SEE AY501
VENTED SHEET METAL SOFFIT PANELS, TYPICAL AT OVERHANGS -
HOT WATER TANK - SEE PLUMBING PLAN
KEY NOTE KEY NOTE
EMERGENCY EYE WASH STATION - SEE PLUMBING PLAN
SEE PLUMBING PLAN
FLOOR MOUNTED MOP SINK, AND WALL MOUNTED FAUCET -
BASE TRIM - SEE AY602
WALL CABINETS
AND BACKSPLASH
BASE CABINETS WITH SOLID SURFACE COUNTERTOP
HOSE - SEE PLUMBING PLAN
KITCHEN SINK, FAUCET, SOAP DISPENSER, AND HANDSPRAY
PAPER TOWEL DISPENSER
PURLINS PER PEMB MANUFACTURER
MANUFACTURER
DIAGONAL BRACING FOR MOMENT FRAME PER PEMB
MOMENT FRAME PER PEMB MANUFACTURER
WALL GIRTS & SECONDARY FRAMING PER PEMB MANUFACTURER
CONCRETE APRON - SEE CIVIL
CONTRACTOR DESIGN
FOUNDATION DRAIN PER CIVIL; CONC FOUNDATION PER
WINDOW, TYPICAL - SEE AY601
EXHAUST FAN, DAMPER, AND WEATHERHOOD - SEE MECHANICAL
COILING OVERHEAD DOOR, TYPICAL - SEE AY601
SUSPENDED CEILING - SEE SHEET AY102 AND AY602
PERSONNEL DOOR, TYPICAL - SEE AY101 AND AY601
CONTRACT
FUTURE REFRIGERATOR LOCATION - APPLIANCE NOT IN
CONTRACT - SEE PLUMBING
FUTURE WASHER AND DRYER LOCATION - APPLIANCES NOT IN
EMBEDDED PIPE BOLLARD - SEE SHEET AY503
SURFACE-MOUNTED PIPE BOLLARD - SEE SHEET AY503
32 HOIST BEAM - SEE MECHANICAL
AT ALL SIDES - SEE SHEET AY501
FOUNDATION INSULATION WITH PROTECTIVE COATING, TYPICAL
SLOPED CONCRETE FLOOR - SEE SHEET AY10233
36 LIGHTING, EXIT SIGNS AND ELECTRICAL EQUIPMENT
SINGLE PIECE TWO-WALL GRAB BAR
SANITARY NAPKIN DISPOSAL
TOILET TISSUE DISPENSER
SEMI-RECESSED FIRE EXTINGUISHER CABINET
NOT IN USE
WATER CLOSET - SEE PLUMBING PLAN
COMBINATION COAT HOOK AND BUMPER
CERAMIC WALL TILE - SEE SHEET AY602
SHEET AY602
PAINTED MDO PLYWOOD WALL FINISH AS SCHEDULED, SEE
DAMPER - SEE MECHANICAL
LOUVER - SEE SHEETS AY503 AND AY601
FLOOR DRAIN / TRENCH DRAIN - SEE PLUMBING PLAN
KEY NOTE
SURFACING AGGREGATE - SEE LANDSCAPE PLAN
BUILDING SECTION A-A
SCALE: 1/4" = 1'-0"
A
BUILDING SECTION D-D
SCALE: 1/4" = 1'-0"
D
BUILDING SECTION E-E
SCALE: 1/4" = 1'-0"
EBUILDING SECTION B-B
SCALE: 1/4" = 1'-0"
B
BUILDING SECTION C-C
SCALE: 1/4" = 1'-0"
C
AY101
AY101
AY101AY101
AY101
BEYOND
4' 8'0 2'
4' 8'0 2'
4' 8'0 2'
4' 8'0 2'
4' 8'0 2'
NOT IN USE
UNDER SLAB VAPOR BARRIER AND COMPACTED GRAVEL BASE
NOT IN USE
NOT IN USE
NOT IN USE
KEY NOTES:
AY503
AY503
AY501
AY502
AY502
AY501
AY501
AY501
AY501
AY502
AY502
AY501
AY502
AY502
AY501
AY501
AY503
8" +/-
"4
A B
O V
E F
L O
O R
C
L E
A R
(3'-0" MIN)
3'-3" +/-
2'-0"
F
IN
IS
H
F L
O O
R D
IS
P
E N
S E
R T
O P
A P
E R
T O
W E
L B
O T
T O
M O
F
M
A X
F R
O M
3'-0" +/-
F
IN
IS
H
F L
O O
R H
A N
D L
E
F
R
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
IN
E
R
IO
R E
L E
V A
T
IO
N S
M A
IN
T
E N
A N
C E
O
F F
IC
E
B U
IL
D
IN
G
AY401
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
/0
/2
B C
O E
S R
E V
IE
W
D X
F .1
A
Y .d g n
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
C L
OPEN
BELOW
COUNTER
C L
A AA
AY104
C L19
AY103 AY102
KEY NOTE KEY NOTE
LIGHT FIXTURE - SEE ELECTRICAL
COUNTERTOP AND BACKSPLASH
WALL-MOUNTED CABINET WITH SOLID SURFACE
TOWEL DISPENSER, PROVIDE PLYWD SPACER (MATCH TILE THICKNESS)
PAPER TOWEL DISPENSER, IF TILE IS OMITTED BEHIND THE PAPER
WINDOW, TYPICAL - SEE WINDOW SCHEDULE
CEILING PLAN ON SHEET AY102
SUSPENDED ACOUSTIC CEILING TILE CEILING - SEE REFLECTED
PERSONNEL DOOR, TYPICAL - SEE DOOR SCHEDULE
CEILING PLAN ON SHEET AY102
SUSPENDED GYPSUM BOARD CEILING - SEE REFLECTED
PLYWD SPACER (MATCH TILE THICKNESS)
MIRROR 24" X 36", IF TILE IS OMITTED BEHIND THE MIRROR, PROVIDE
BLOCKING IN STUD WALL CAVITY FOR SECURE MOUNTING
SINGLE PIECE TWO-WALL GRAB BAR, PROVIDE SOLID WOOD
SANITARY NAPKIN DISPOSAL
TOILET TISSUE DISPENSER
SEMI-RECESSED FIRE EXTINGUISHER CABINET
WATER CLOSET - SEE PLUMBING PLAN
LAVATORY, SOAP DISPENSER AND FAUCET - SEE PLUMBING PLAN
WALL TILE PER FINISH SCHEDULE - SEE SHEET AY602
SCALD COVER
SOLID SURFACE SILL AT WINDOW WITH 2" LIP
BASE TRIM PER FINISH SCHEDULE - SEE SHEET AY602
RESTROOM INTERIOR ELEVATION
SCALE: 3/8" = 1'-0"AY101
A RESTROOM INTERIOR ELEVATION
SCALE: 3/8" = 1'-0"AY101
B RESTROOM INTERIOR ELEVATION
SCALE: 3/8" = 1'-0"AY101
C
GYPSUM BOARD WALL FINISH PER FINISH SCHEDULE - SEE SHEET AY602
CONFERENCE ROOM INTERIOR ELEVATION
SCALE: 3/8" = 1'-0"AY101
D CONFERENCE ROOM INTERIOR ELEVATION
SCALE: 3/8" = 1'-0"AY101
E CORRIDOR INTERIOR ELEVATION
SCALE: 3/8" = 1'-0"AY101
F
0 2' 4' 6'
0 2' 4' 6' 0 2' 4' 6' 0 2' 4' 6'
0 2' 4' 6'0 2' 4' 6'
ROOM SIGN - SEE SHEET AY603
KEY NOTES:
NOT IN USE
NOT IN USE
NOT IN USE
NOT IN USE
NOT IN USE
NOT IN USE
NOT IN USE
NOT IN USE
NOT IN USE
NOT IN USE
CONTINUOUS BUTYL SEALANT
FINISH FLOOR AS SCHEDULED
WALL BASE AS SCHEDULED
TO CONCRETE CURB BY PEMB MFR
ATTACHMENT
CONTINUOUS BASE ANGLE AND
CLIP ANGLE FRAMING
CONTINUOUS LIGHT GA METAL
WALL FINISH AS SCHEDULED
6"
S E
E A
Y
V A
R
IE
S
TO SLAB
CONCRETE CURB INTEGRAL
METAL BASE TRIM
WALL PANEL
INSULATED METAL
PROTECTIVE COATING
INSULATION WITH
R-10 XPS FOUNDATION
PER CIVIL
& JOINT FILLER
CONC PAVING
/2
G
A P
FOUNDATION SLAB/FOOTING
CONTINUE TO BOTTOM OF
R-10 XPS FOUNDATION INSULATION,
BUTYL TAPE
CONTINUOUS
WALL PANEL
INSULATED METAL
METAL TRIM
GUTTER
AT HIGH RIBS
GUTTER HANGERS
BUTYL TAPE TOP AND BOTTOM
INSIDE CLOSURE STRIP WITH
PANEL
METAL ROOF
INSULATED
INSULATED METAL WALL PANEL
SOFFIT PANELS
VENTING METAL
INSULATED METAL ROOF PANEL
METAL RAKE FASCIA
TRIM
CLOSURE
METAL RAKE
CONTINUOUS BUTYL TAPE
S E
E S
H E
E T
A Y
R A
K E
O V
E R
H A
N G
P
U R
L
IN
PURLINS
OF PANEL AND AT
BUTYL TAPE AT TOP
CONTINUOUS
CLIP ANGLE
LIGHT GA METAL
WALL PANEL
INSULATED METAL
WALL
AT TOP OF
FRAMING
8" C-GIRT
METAL CLOSURE TRIM
ROOF PURLIN
METAL BASE TRIM
FACE OF WALL PANEL
EXTEND 6" MINIMUM BEYOND
METAL TRANSITION FLASHING,
6"
CLOSURE STRIP
BUTYL TAPE AT
TRANSITION FLASHING
BACK OF METAL
TAPE FRONT AND
CONTINUOUS BUTYL
ROOF PANEL
INSULATED METAL
DAMPPROOFING
SEE CIVIL
BASE MATERIAL,
INFILL FRAMING
8" METAL STUD
SLAB PER PEMB MFR
CONTINUOUS BUTYL SEALANT
AS SCHEDULED
FINISH FLOOR
AS SCHEDULED
WALL BASE
CURB BY PEMB MFR
ATTACHMENT TO CONCRETE
CONTINUOUS BASE ANGLE AND
CLIP ANGLE FRAMING
CONTINUOUS LIGHT GA METAL
WALL FINISH AS SCHEDULED
6"
V A
R
IE
E
A Y
INTEGRAL TO SLAB
CONCRETE CURB
METAL BASE TRIM
WALL PANEL
INSULATED METAL
PROTECTIVE COATING
INSULATION WITH
R-10 XPS FOUNDATION
/2
SLAB/FOOTING
TO BOTTOM OF FOUNDATION
CONTINUE FOUNDATION INSULATION
DAMPPROOFING
SEE SHEET L-001
PER LANDSCAPE PLAN,
SURFACING AGGREGATE
INFILL FRAMING
8" METAL STUD
PEMB MFR
SLAB PER
B
E L
O W
G R
A D
E C
O A
T
IN
G M
IN
IM
U M
C O
N T
IN
O T
E C
T
IV
SEE SHEET C-207
FOUNDATION DRAIN PER CIVIL,
/2
JOINT
SEALANT
ACOUSTICAL
CONTINUOUS
1/4" NOMINAL
SEALANT JOINT
ACOUSTICAL
CONTINUOUS
1/4" NOMINAL
SEALANT JOINT
ACOUSTICAL
CONTINUOUS
1/4" NOMINAL
SEALANT AT TOP AND BOTTOM
CLOSURE STRIP WITH BUTYL TAPE
INSULATED METAL ROOF PANEL
1'-0"
TOP AND BOTTOM
WITH BUTYL TAPE SEALANT
CONTINUOUS METAL CLOSURE
RIDGE CAP TRIM
PURLINS AT RIDGE
CLOSURE TRIM BETWEEN
CONTINUOUS
SPRAY FOAM INSULATION
FILL VOID WITH FIELD APPLIED
ROOF PURLIN
AT HIGH RIBS
STRUCTURE
FASTENER TO
ROOF PANEL
AT PURLINS
AND BUTYL TAPE AT
CONTINUOUS TRIM
EAVE STRUT
OVERHANG PER SHEET AY101
CUT EDGE OF SOFFIT PANEL
SHEET METAL TRIM TO COVER
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
/0
/2
D X
F .1
A
Y .d g
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
T
A
IL
S
M A
IN
T
E N
A N
C E
O
F F
IC
E
B U
IL
D
IN
G
AY501
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
B C
O E
S R
E V
IE
W
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
INSIDE
OUTSIDE
INSIDEOUTSIDE
W3
SLOPE AWAY
FROM BUILDING
DRIP FLASHING
DRIP FLASHING
DETAIL: ROOF EAVE
SCALE: 3"=1'-0"AY301
DETAIL: ROOF RAKE
SCALE: 3"=1'-0"AY301
DETAIL: WALL BASE AT PAVING
SCALE: 3"=1'-0"AY301
DETAIL: ROOF TO WALL TRANSITION
SCALE: 3"=1'-0"AY301
5DETAIL: WALL BASE AT GRADE
SCALE: 3"=1'-0"AY301
0 3" 6" 9" 12"
0 3" 6" 9" 12"
0 3" 6" 9" 12"
0 3" 6" 9" 12"0 3" 6" 9" 12"
AY301
DETAIL: ROOF RIDGE
SCALE: 3"=1'-0" 0 3" 6" 9" 12"
CAP TRIM
HEAD FLASHING
JAMB TRIM BEYOND
WINDOW PER SCHEDULE
BOARD RETURN
PAINTED GYPSUM
CAULK
SILICONE SEALANT
BOARD
GYPSUM
PAINTED
HEADER
C-GIRT
BOARD
GYPSUM
PAINTED
CAULK
BULLNOSE
WINDOW SILL,
SOLID SURFACE
SINGLE PIECE, 1/2"
C-GIRT SILL
WINDOW PER SCHEDULE
JAMB TRIM BEYOND
SILICONE SEALANT
CAP TRIM
WALL PANEL
INSULATED METAL
WEEPS, DO NOT BLOCK
SHIM PER MFR
EXTENDED WINDOW SILL
EXTENDED WINDOW HEAD
BUTYL SEALANT
SEALANT
BUTYL
WALL PANEL
INSULATED MTL
WALL PANEL
INSULATED MTL
WALL PANEL
INSULATED MTL
JAMB
WALL GIRT
AND SILL
WINDOW FRAME
MULLION
WINDOW
BOARD RETURN
PAINTED GYPSUM
SILICONE SEALANT
SCHEDULE
WINDOW PER
CAP TRIM
CAULK
BOARD
PAINTED GYPSUM
CAULK
CAP TRIM
FRAME AND SILL
EXTENDED WINDOW
STUDS AT JAMB
PAIR OF LT GA MTL
BOARD RETURN
PAINTED GYPSUM
SCHEDULE
WINDOW PER
SEALANT
SILICONE
SCHEDULE
WINDOW PER
SEE DOOR SCHED
DOOR BOTTOM,
HARDWARE AT
BEYOND
FRAME
HM DOOR
BEYOND
FINISH
PAINTED
BEYOND
WALL PANEL
INSUL MTL
SLAB
BUILDING
PER CIVIL
CONC PAVING
BEYOND
FRAME
HM DOOR
BEYOND
FINISH
PAINTED
BEYOND
WALL PANEL
INSUL MTL
CAULK
WATERPROOFING
INSULATION OVER
FOUNDATION
R-10 XPS
PANEL ABOVE
LINE OF WALL
C U
R B
C
O N
C
BELOW
FRAMING
CLIP ANGLE
LT GA MTL
BOARD WITH RETURN
PAINTED GYPSUM
BELOW
FRAMING
CLIP ANGLE
LT GA MTL
WALL PANEL
INSULATED MTL
CAP TRIM
FRAMING
WALL GIRT
CAP TRIM
HEAD FLASHING
JAMB TRIM BEYOND
HM DOOR FRAME
THERMALLY BROKEN
WALL PANEL
INSULATED MTL
RETURN
BOARD WITH
PAINTED GYPSUM
CAULK
HEADER
C-GIRT
SEALANT
BUTYL
BEYOND
WALL PANEL
INSUL MTL
SEALANT
BUTYL
SEALANT
BUTYL
PER SCHEDULE
INSUL HM DOOR
PER SCHEDULE
INSUL HM DOOR
HEADER
C-GIRT
PLYWOOD
PAINTED MDO
BREAK WITH DOOR BOTTOM SEAL
POLYURETHANE SEALANT, ALIGN
CONTINUOUS BEAD OF
SEE DOOR SCHEDULE, SET IN A
THERMALLY BROKEN ADA THRESHOLD,
FRAME
BOTH SIDES OF
SILICONE SEALANT
1/4" NOMINAL
ANGLE
BASE
FRAMING
SLAB
BUILDING
PER CIVIL
CONC PAVING
PER CIVIL
JOINT FILLER
1/2"EXPANSION
BEYOND
WALL PANEL
INSUL MTL
BEYOND
ANGLES
DOOR JAMB
COILING
WEATHER SEAL
SCHEDULE
DOOR, SEE DOOR
INSULATED COILING
CAP TRIM
HEAD FLASHING
BEYOND
JAMB TRIM
WALL PANEL
INSULATED MTL
SEALANT
BUTYL
CHANNEL HEADER
PAINTED STEEL
WEATHER SEAL
SCHEDULE
DOOR, SEE DOOR
INSULATED COILING
COILING DOOR HOOD
CAP TRIM
WALL FINISH COLOR
FRAMING TO MATCH
PAINT EXPOSED STEEL
PANEL
MTL WALL
INSULATED
ANGLE BELOW
BASE
FRAMING
DAMPPROOFING
INSULATION OVER
FOUNDATION
R-10 XPS
ANGLE DOOR GUIDES
PAINTED DOUBLE
PANEL ABOVE
LINE OF WALL
FRAMING, CLOSE GAP AT CURB
PAINTED LT GA MTL CLIP ANGLE
FRAMING AT DOOR JAMB
PAINTED STEEL CHANNEL
PLYWOOD
PAINTED MDO
PLYWOOD
PAINTED MDO
PLYWOOD
PAINTED MDO
PLYWOOD
PAINTED MDO
REINFORCING AT EXPOSED CORNERS
FOUNDATION INSULATION WITH LATH
PROTECTIVE COATING OVER
AT FASTENER
SHIM TIGHT
FRAME
BROKEN HM DOOR
THERMALLY
PER SCHEDULE
INSUL HM DOOR
BELOW
THRESHOLD
BROKEN ADA
THERMALLY
SCHEDULE
PER HARDWARE
WEATHERSTRIPPING
BEYOND
INSULATION
FOUNDATION
COATED
LINE OF
BEYOND
INSULATION
FOUNDATION
LINE OF
6"
M
IN"
BELOW
WINDOW SILL
SINGLE PIECE
FRAME
CAULK AT WINDOW
RADIUS EDGE
APRON TRIM, 1/8"
SOLID SURFACE
1-1/2" X 1/2"
BOARD RETURN
PAINTED GYPSUM
CAULK
BELOW
WINDOW SILL
SINGLE PIECE
C
O N
C C
U R
B
G
IR
T
F R
A M
IN
G
G
IR
T
F R
A M
IN
G
TO MATCH WALL FINISH COLOR
PAINT EXPOSED STEEL FRAMING
BUTYL SEALANT
CONTINUOUS
BUTYL SEALANT
SEALANT
BUTYL
BUTYL SEALANT
2"
"4
C
O N
C C
U R
B
SCHEDULE
PER HARDWARE
WEATHERSTRIPPING
SCHEDULE
PER HARDWARE
WEATHERSTRIPPING
CAULK
FRAME
BROKEN HM DOOR
THERMALLY
PER SCHEDULE
INSUL HM DOOR
BELOW
THRESHOLD
BROKEN ADA
THERMALLY
OF FRAME
SEALANT BOTH SIDES
3/8" NOM SILICONE
M
A X
B
E V
E L
L E
D
2"
FOUNDATION INSULATION
PROTECTIVE COATING OVER
SCHEDULE
PER HARDWARE
WEATHERSTRIPPING
FRAME
BROKEN HM DOOR
THERMALLY
PER SCHEDULE
INSUL HM DOOR
BELOW
THRESHOLD
BROKEN ADA
THERMALLY
WATERPROOFING
INSULATION OVER
FOUNDATION
R-10 XPS
PANEL ABOVE
LINE OF WALL
FOUNDATION INSULATION
PROTECTIVE COATING OVER
SCHEDULE
PER HARDWARE
WEATHERSTRIPPING
FRAME
BROKEN HM DOOR
THERMALLY
PER SCHEDULE
INSUL HM DOOR
BELOW
THRESHOLD
BROKEN ADA
THERMALLY
BELOW
FRAMING
CLIP ANGLE
LT GA MTL
WALL PANEL
INSULATED MTL
FRAMING
WALL GIRT
ANGLE
BASE
FRAMING
AT FASTENER
SHIM TIGHT
BUTYL SEALANT CAP TRIM
FRAME
BOTH SIDES OF
SILICONE SEALANT
1/4" NOMINAL
FRAME
BOTH SIDES OF
SILICONE SEALANT
1/4" NOMINAL
2"
2"
FRAME
BOTH SIDES OF
SILICONE SEALANT
1/4" NOMINAL
2"
BOARD WITH RETURN
PAINTED GYPSUM
SEE DOOR SCHED
DOOR BOTTOM,
HARDWARE AT
BEYOND
WALL PANEL
INSUL MTL
BEYOND
INSULATION
FOUNDATION
COATED
LINE OF
JOINT PER CIVIL
1/2" EXPANSION
PER CIVIL
CONC PAVING
BREAK WITH DOOR BOTTOM SEAL
POLYURETHANE SEALANT, ALIGN
CONTINUOUS BEAD OF
SEE DOOR SCHEDULE, SET IN A
THERMALLY BROKEN ADA THRESHOLD,
SLAB
BUILDING
SCHEDULE
PER HARDWARE
WEATHERSTRIPPING
WALL FINISH COLOR
FRAMING TO MATCH
PAINT EXPOSED STEEL
OF FRAME
SEALANT BOTH SIDES
3/8" NOM SILICONE
HEAD FLASHING
JAMB TRIM BEYOND
HM DOOR FRAME
THERMALLY BROKEN
PER SCHEDULE
INSUL HM DOOR
WALL PANEL
INSULATED MTL
PER SCHEDULE
INSUL HM DOOR
SEALANT AT STEEL CHANNEL
1/4" NOM PAINTED POLYURETHAN
3"+/-
WEATHER SEAL
SEE DOOR SCHEDULE
INSULATED COILING DOOR,
SEE DOOR SCHEDULE
INSULATED COILING DOOR,
WEATHER SEAL
ANGLE DOOR GUIDES
PAINTED DOUBLE
C
O N
C C
U R
B
DOOR JAMB
FRAMING AT
PAINTED STEEL
CHANNEL
SEALANT AT STEEL
POLYURETHAN
1/4" NOM PAINTED
BELOW
FRAMING
CLIP ANGLE
LT GA MTL
FRAMING BELOW
LT GA MTL CLIP ANGLE
BELOW
FRAMING
CLIP ANGLE
LT GA MTL
EXPANSION JOINT
SEALANT AT TOP OF
1/2" POLYURETHANE
PER SCHEDULE
FINISH FLOOR
EXPANSION JOINT
SEALANT AT TOP OF
1/2" POLYURETHANE
JOINT PER CIVIL
1/2" EXPANSION
EXPANSION JOINT
SEALANT AT TOP OF
1/2" POLYURETHANE
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
T
A
IL
S
M A
IN
T
E N
A N
C E
O
F F
IC
E
B U
IL
D
IN
G
AY502
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
/0
/2
B C
O E
S R
E V
IE
W
D X
F
.1
A Q
Y
.d g n
2% SLOPE
MAX NET
GLAZING
TYPICAL
2% SLOPE 2% SLOPE
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
DETAIL: INTERMEDIATE WINDOW JAMB
SCALE 3"=1'-0"AY101
1 DETAIL: DOOR JAMB 1a
SCALE 3"=1'-0"AY101
5 DETAIL: DOOR JAMB 2a
SCALE 3"=1'-0"AY101
9 DETAIL: COILING JAMB 1a
SCALE 3"=1'-0"AY101
DETAIL: WINDOW JAMB & MULLION
SCALE 3"=1'-0"AY101
2 DETAIL: DOOR JAMB 1b
SCALE 3"=1'-0"AY101
6 DETAIL: DOOR JAMB 2b
SCALE 3"=1'-0"AY101
10 DETAIL: COILING JAMB 1b
SCALE 3"=1'-0"AY101
DETAIL: WINDOW HEAD
SCALE 3"=1'-0"AY301
3 DETAIL: DOOR HEAD 1
SCALE 3"=1'-0"AY601
7 DETAIL: DOOR HEAD 2
SCALE 3"=1'-0"AY301
11 DETAIL: COILING DOOR HEAD
SCALE 3"=1'-0"AY101
DETAIL: WINDOW SILL
SCALE 3"=1'-0"AY301
4 DETAIL: DOOR THRESHOLD 1
SCALE 3"=1'-0"AY601
8 DETAIL: DOOR THRESHOLD 2
SCALE 3"=1'-0"AY301
12 DETAIL: COILING DOOR THRESHOLD
SCALE 3"=1'-0"AY101
0 3" 6" 9" 12"0 3" 6" 9" 12"0 3" 6" 9" 12"0 3" 6" 9" 12"
0 3" 6" 9" 12" 0 3" 6" 9" 12" 0 3" 6" 9" 12" 0 3" 6" 9" 12"
0 3" 6" 9" 12"0 3" 6" 9" 12"0 3" 6" 9" 12"0 3" 6" 9" 12"
0 3" 6" 9" 12" 0 3" 6" 9" 12" 0 3" 6" 9" 12" 0 3" 6" 9" 12"
JAMB
C-GIRT
SIDES
AND BACKER ROD, BOTH
SILICONE SEALANT
PER SCHEDULE
LOUVER-DAMPER
COMBINATION
CAP TRIM
PLYWOOD
PAINTED MDO
GYPSUM BOARD
PLYWOOD OVER
PAINTED MDO
FRAME
HM DOOR
PER SCHEDULE
HM DOOR
FRAME
SEALANT AROUND
ACOUSTICAL
1/4" NOMINAL
SCHEDULE
PER HARDWARE
WEATHERSTRIPPING
THRESHOLD BELOW
FRAME
HM DOOR
PER SCHEDULE
HM DOOR
CAULK
SCHEDULE
PER HARDWARE
WEATHERSTRIPPING
SEE ELEVATIONSON SHEET AY201
WEATHERHOOD, WHERE OCCURS,
HM DOOR FRAME
FRAME
AROUND
SEALANT
ACOUSTICAL
1/4" NOMINAL
PER SCHEDULE
HM DOOR
CAP TRIM
AT WEATHERHOOD
HEAD FLASHING, EXCEPT
PER SCHEDULE
LOUVER-DAMPER
COMBINATION
AND BACKER ROD
SILICONE SEALANT
PLYWOOD
PAINTED MDO
C-GIRT HEADER
/4
SEALANT
BUTYL
EXTRUDED HEAD
GYPSUM BOARD
PLYWOOD OVER
PAINTED MDO
SCHEDULE
PER HARDWARE
WEATHERSTRIPPING
HM DOOR FRAME
CAULK
PER SCHEDULE
HM DOOR
SCHEDULE
PER HARDWARE
WEATHERSTRIPPING
CAULK
ON SHEET AY201
SEE ELEVATIONS
WHERE OCCURS,
WEATHERHOOD,
AS SCHEDULED
WALL FINISH
C-GIRT SILL
PER SCHEDULE
LOUVER-DAMPER
COMBINATION
AND BACKER ROD
SILICONE SEALANT
AT WEATHERHOOD)
EXTENDED SILL (EXCEPT
WALL PANEL
INSULATED METAL
SEALANT
BUTYL
SCREEN
INSECT
EXTRUDED SILL
(B E
V E
L L
E D
/2 M
SEE DOOR SCHED
DOOR BOTTOM,
HARDWARE AT
SLAB
GARAGE
SLOPED
PER SCHEDULE
HM DOOR
WITH DOOR BOTTOM SEAL
OF POLYURETHANE SEALANT, ALIGN BREAK
DOOR SCHEDULE, SET IN A CONTINUOUS BEAD
THERMALLY BROKEN ADA THRESHOLD, SEE
PER SCHEDULE
HM FRAME
SCHEDULE
PER ROOM FINISH
FINISH FLOOR
URETHANE SEALANT
BEAD OF POLY-
PER SCHEDULE
HM DOOR
PER SCHEDULE
HM FRAME
SCHEDULE
PER ROOM FINISH
FINISH FLOOR SCHEDULE
PER ROOM FINISH
FINISH FLOOR
SCHEDULE
SEE DOOR
OCCURS,
UNDERCUT WHERE
CAP TRIM
AND MECHANICAL
ON SHEET AY201
SEE ELEVATIONS
WHERE OCCURS,
WEATHERHOOD,
SEALANT
BUTYL
WALL PANEL
INSULATED MTL
WALL PANEL
INSULATED MTL
INSECT SCREEN
SCREEN
INSECT
SEALANT AROUND FRAME
1/4" NOMINAL ACOUSTICAL
AROUND FRAME
ACOUSTICAL SEALANT
1/4" NOMINAL
SCHEDULE
PER ROOM FINISH
FINISH FLOOR
BOTH SIDES
SEALANT JOINT,
ACOUSTICAL
CONTINUOUS
1/4" NOMINAL
BOARD
GYPSUM
PAINTED
BOARD
OVER GYPSUM
PLYWOOD
PAINTED MDO
AS SCHEDULED
WALL BASE
2"
2"
BOARD
GYPSUM
PAINTED
BOARD
GYPSUM
PAINTED
STEEL PIPE, SCHEDULE 40
4" INSIDE DIAMETER PAINTED
MATERIAL AROUND BOLLARD
1/2" THICK EXPANSION JOINT
SUBSURFACE PREP
SEE CIVIL FOR
SCHEDULE 40
PAINTED STEEL PIPE,
4" INSIDE DIAMETER
AS INDICATED
WELD TO STEEL PIPE
STEEL BASE PLATE,
1/2" THICK PAINTED
9"
TYP
"2
T
Y P
THE CONC SLAB
HOLES DRILLED INTO
INSERTS SET IN
STAINLESS STEEL
THREADED
WITH ADHESIVE-SET
BOLTS AND WASHERS
STAINLESS STEEL
(4) 1/2" X 4" LONG
CAP PLATE, WELDED TO PIPE
1/4" X 4 1/2" DIAMETER STEEL
S P
A C
IN
G
T
Y P
TAPE
WIDE REFLECTIVE
4 ROWS OF 1/2"
WELD
HOLE, TACK
BAR, INSTALL IN
DIAMETER STEEL
7" X 1/2"
CONCRETE FOOTING
DIAMETER
1' 3"
" 1
" PAVING PER CIVIL
WELDED TO PIPE
CAP PLATE,
DIAMETER STEEL
1/4" X 4 1/2"
S P
A C
IN
G
T
Y P
/2
MIDDLE
HOLE IN PIPE AT
1/2" DIAMETER
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P O
R T
L A
N D
O
R E
G O
N
P O
R T
L A
N D
D
IS
T R
IC
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
D A
T E
T T
H E
W G
Z A
N G
E R
R
A
A N
S I
F
H A
R P
O L
E
M A
T T
H E
W G
Z A
N G
E R
R
A
T A
T
A
IL
S
M A
IN
T
E N
A N
C E
O
F F
IC
E
B U
IL
D
IN
G
AY503
U
L T
F
IS
H F
A C
IL
IT
Y U
P G
R A
D E
W N
R
X T
E R
D A
M A
N D
R E
S E
R V
O
IR
/0
/2
B C
O E
S R
E V
IE
W
D X
F .1
A
Y .d g n
W3 W4
W3 W4
2% SLOPE
W3
CORRIDOR
BAY
MAINTENANCE
BAY
MAINTENANCE CORRIDOR
D
C
A
B
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
A
PLAN A ELEVATION VIEW
1/4"
1/8"
1/8"
DETAIL: LOUVER-DAMPER JAMB
SCALE: 3"=1'-0"AY101
DETAIL: LOUVER-DAMPER HEAD
SCALE: 3"=1'-0"AY301
DETAIL: LOUVER-DAMPER SILL
SCALE: 3"=1'-0"AY301
3 DETAIL: SMOKE DOOR THRESHOLD
SCALE: 3"=1'-0"AY301
DETAIL: SMOKE DOOR HEAD
SCALE: 3"=1'-0"AY301
DETAIL: SMOKE DOOR JAMB
SCALE: 3"=1'-0"AY101
DETAIL: TYP INTERIOR DOOR THRESHOLD
SCALE: 3"=1'-0"AY301
DETAIL: TYP INTERIOR DOOR HEAD
SCALE: 3"=1'-0"AY301
DETAIL: TYP INTERIOR…
This is the start of the file's text. The full file is on GovTribe.