1. We are reusing the existing Motor and Discharge Head

2. Information pertaining to existing pump bowl is as follows:

a. Equal or equivalent.

b. Original is a Fairbanks morse

i. 3 stage model 11 H

ii. 1500 GPM @ 118’ of head.

c. Driven by our existing motor.

i. 60 Hp

ii. 1765 RPM

d. The bowl assembly is

i. 50-3/4” long with the bowl stages being 11-1/4” wide

ii. The strainer at the bottom is 8” long by 12” wide ** this we need to stay under

12”

iii. Total length from pump threaded discharge to bottom of strainer is 62-3/4” long

iv. The pump shaft extends 11” beyond top of Threaded column adapter.