Drawings_W9127N-17-B-0003.pdf
PDF 2 MB Posted
- Solicitation number
- W9127N-17-B-0003
About this file
Project Drawings
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers Portland District
JOHN DAY LOCK AND DAM
ADULT FISH LADDER
PIT TAG ANTENNA
INSTALLATION
THIS PROJECT WAS DESIGNED BY THE PORTLAND
DISTRICT OF THE U.S. ARMY CORPS OF ENGINEERS.
THE INITIALS OR SIGNATURES AND REGISTRATION
DESIGNATIONS OF INDIVIDUALS APPEAR ON THESE
PROJECT DOCUMENTS WITHIN THE SCOPE OF THEIR
EMPLOYMENT AS REQUIRED BY ER 1110-1-8152.
{v'.rLANCEA. HELWIG, P.E.
CHIEF, ENGINEERING & CONSTRUCTION DIVISION
'2.01~0'1)0
SOLICITATION NUMBER: W9127N-17-B-0003
1 I 2 I 3 I 4 I 5
SHEET SHEET SHEET ml REVISION SHEET ACTION REVISION SHEET# ACTION REVISl()N DRAWING ACTION
MARK FILE NAME ID DRAWING TITLE No. MARK of# DRAWING No. DRAWING TITLE No. MARK FILE NAME No. DRAWING TITLE No. US Army Corps of i:::nglneers$
PORTLAND DISTRICT
GENERAL PLANS
INFORMATIONAL PLANS FROM PACIFIC STATES MARINE FISHERIES COMMISSION INFORMATIONAL PLANS
A JDG-1-0-1 /29 CONSTRUCTION BASELINE LAYOUT HORIZONTAL AND VERTICAL CON1ROL s
DRILL GUIDES, (I 5) SHEETS c JDF-1-0-2/1 NORTH SHORE FISH LADDER-1 ON 10 GENERAL LAYOUT PLANS s l JDFl. l09_G-001XXX.DGN G-001 DRAl'llNG INDEX 2 s 0 I of lS JDA FITTING PLUG-DRILL GUIDES OVERVIEW s c JDF-1-0-2/2 NORTH SHORE FISH LADDER;-1ON10 ELEVATIONS JD Fl. I 09_G-002XXX.DGN G-002 GENERAL NOTES AND SYMBOLS
2of lS JDA FITTING PLUG-DRILL GUIDES ORIFICE s c JDF-1-0-2/3 NORTH SHORE FISH LADDER-I ON 10 GENERAL LAYOUT SECTIONS I s 0 JD Fl. I 09_G-003XXX.DGN G-003 DIS1RICT BOUNDARY, LOCAL VICINITY, PROJECT SITE MAPS 2
ORIFICE TOP s D JDF-10,0-0-3/1 SOUTH SHORE FISH LADDER GENERAL LAYOUT PLAN s D AND PROJECT PHOTO 0 3 of IS JOA FITTING PLUG-DRILL GUIDES
~ 0 4 of lS JDA FITTING PLUG-DRILL GUIDES ORIFICE LEFT 5 B JDH-4-2/34 NORTH SHORE FISH LADDER-1 ON 10 SECTIONS Nos 6 & 7 s STRUCTURAL PLANS 0 S of lS JDA FITTING PLUG-DRILL GUIDES ORIFICE RIGHT 5 PLAN, ELEVATION &SECTIONS
0 6 oflS JOA FITTING PLUG-DRILL GUIDES ORIFICE BOTTOM s D JDF-1-4-2/37 NORTH SHORE FISH LADDER-I ON 10 SECTION No.8 s GENERAL STRUCTURAL SHEETS, (1) SHEET 0 7 of IS JOA FITTING PLUG-DRILL GUIDES ORIFICE PARTS CONDUIT & CAPACITOR 5 PLAN, ELEVATION & SECTIONS
JDFI .109_S-OOIXXX.DGN S-001 GENERAL STRUCTURAL NOTES 2 0 8 oflS JDA FITTING PLUG-DRILL GUIDES ORIFICE PARTS PLASTIC s B JDF-1-4-2-40 NORTH SHORE FISH LADDER-1 ON 10 SECTIONS Nos.9 & 10 s 0 9 oflS JOA FITTING PLUG-ORI LL GUIDES ORIFICE & OVERFLOW PARTS TUlllNG s PLAN, ELEVATION, & SECTIONS 0 IOoflS JOA FITTING PLUG-DRILL GUIDES OVERFLOW s
NORTH SHORE FISH LADDER-1 ON 10 WEIRS I SS TO 263 CONCRETE OUTLINE s o· 11 of lS JDA FITTING PLUG-DRILL GUIDES. OVERFLOW OUTSIDE WALL s E JDF-l-4-2/S2
NORTH SHORE FISH LADDER l'/EIR MODIFICATION, FEATURE 'N", (2) SHEETS 12 of lS JDA FITTING PLUG-DRILL GUIDES OVERFLOW INSIDE \'/ALL s A JDf-1-4-3/9 SOTH SHORE FISH LADDER SECTIONS Nos. 4 & S-CONCRETE OUTLINE I s 0 PLAN, ELEVATION, AND SECTIONS JDFI .109_SNOOIJ()()(,DGN sNOOl NORTH SHORE FISH LADDER PIT TAG ANTENNA INSTALLATION 2 0 13 of lS JOA FITTING PLUG-DRILL GUIDES OVERFLOW UPSTREAM s
LOCATION ARRANGEMENT ISOMETRIC 0 14 of IS JDA FITTING PLUG-DRILL GUIDES OVERFLOW 001'/NSTREAM LEFT s A JDF-1-4-3/10 SOUTH SHORE FISH LADDER SECTIONS Nos, 4 & S-CONCRETE OUTLINE II s JD Fl .109_SN101)()()(.DGN SNIOl NORTH SHORE FISH LADDER PIT TAG ANTENNA 2 0 lS of IS JOA FITTING PLUG-DRILL GUIDES OVERFLOW DOWNSTREAM RIGHT s SECTIONS
- LOCATION ARRANGEMENT PLAN B JDF-10.0-4-3/17 SOUTH SHORE FISH LADDER SECTIONS Nos, 6, 7, & 8-CONCRETE OUTLINE I s
ORIFICE ANTENNA SHEETS, (31) SHEETS PLAN, ELEVATION, & SECTIONS
I 1 OF31 JOA ORIFICE ANTENNA OVERVIEW s SOUTH SHORE FISH LADDER WEIR MODIFICATION, FEATURE T, (6) SHEETS 1 2 OF31 JDA ORIFICE ANTENNA EXPLODED VIEW s B JDF-1-4-3/18 SOUTH SHORE FISH LADDER SECTIONS Nos, 6, 7, 8-CONCRETE OUTLINE II s i5
JDFI .109_SS001XXX.DGN SSOOI SOUTH SHORE FISH LADDER PIT TAG ANTENNA 2 I 3 OF31 JOA ORIFICE ANTENNA SHIELD METAL FAB s SECTIONS ~ LOCATION ARRANGEMENT ISOMETRIC 1 40f 31 JOA ORIFICE ANTENNA SHIELD TDP DETAIL s A JDF-1-4-3/49 SOUTH SHORE FISH LADDER WE.IRS 172 THRU 247 ; 249 THRU 252 s ~ JDfl .109_SS101XXX.DGN SSlOI SOUTH SHORE FISH LADDER PIT TAG ANTENNA 2 I S Of 31 JOA ORIFICE ANTENNA SHIELD LEFT DETAIL s CONCRETE OUnlNES
LOCATION ARRANGEMENT PLAN I 60F31 JOA DRIFICEANTENNA SHIELD RIGHT DETAIL s A JDF- l-S-3/2 SOUTH SHORE FISH LADDER HANDRAIL AND FISH BARRIER DETAILS s JDF I. I 09_SS I 02)()()(,DGN SSSOI SOUTH SHORE FISH LADDER TYPICAL LADDER WEIR DEMOLITION 2 I 70f31 )DA ORIFICE ANTENNA SHIELD BOTTOM DETAIL s A JDF-10-S-3/3 SOUTH SHORE FISH LADDER COUNTING STATION MISCELLANEOUS MAETALS s
PLAN, ELEVATION, AND SECTION 1 80F31 JOA ORIFICE ANTENNA SHIELD GROUND LUG DETAIL s
1 JDF-0-4/2 JOHN DAY SOUTH SHORE FISH LADDER U/S BARRIER AND WEIR MODIFICATION 5
1 90F31 JOA ORIFICE ANTENNA PLASTIC INNER ASSEMBLY s PLAN AND SECTION JD Fl. I 09_SS103XXX.DGN SSS02 SOUTH SHORE FISH LADDER TYPICAL LADDER WEIR DEMOLITION AND 2 I 100F31 JOA ORIFICE ANTENNA PLASTIC INNER TOP s ORIFICE ANTENNA INSTALLATION NOTES AND DETAILS I 11 OF31 JOA ORIFICE ANTENNA PLASTIC INNER LEFT s 1 JDF-2-7/l JOHN DAY SOUTH S~ORE FISH LADDER U/S BARRIER AND WEIR MODIFICATION s
JDFl .I 09_SS104)()()(.DGN SSS03 SOUTH SHORE FISH LADDER l'YPICAL LADDER WEIR INSTALLATION 2 1 120F31 JOA ORIFICE ANTENNA PLASTIC INNER RIGHT s DEMOLITION OF WEIR 194 AND MODIFICATION OF WEIRS 19S THRU 206 0 PLAN, ELEVATIONS, AND SECTION 1 130F31 JDA ORIFICE ANTENNA PLASTIC INNER BOTTOM s 1 JDF-2-7/2 JOHN DAY SOUTH SHORE FISH LADDER U/S BARRIER AND l'IEIR MODIFICATION s
JDFl.109_SS1 OSXXX.DGN SSS04 SOUTH AND NORTH SHORE FISH LADDER SUPPORTS FOR 2 1 14 Of 31 JDA OIUFICE ANTENNA PLASTIC OUTER ASSEMBLY s UPSTREAM BARRIER STRUCTURE SHEET 1 TRANSCEIVER PANELS PLAN, ELEVATIONS, AND SECTION 1 IS OF31 JOA ORIFICE ANTENNA PLASTIC OUTER TOP s 1 JDF-2-7/2a JOHN DAY SOUTH SHORE FISH LADDER U/S BARRIER AND WEIR MODIFICATION s
I 160F31 JOA ORIFICE ANTENNA PLASTIC OUTER TOP DETAIL s UPSTREM BARRIER STRUCTURE SHEET 1 a
ELECTRICAL PLANS
1 170F31 JOA ORIFICE ANTENNA PLASTIC OUTER LEFT s 2 JDF-2-7/3 JOHN DAY SOUTH SHORE FISH LADDER U/S BARIUERAND WEIR MODIFICATION s 1 18 OF31 JDA ORIFICE ANTENNA PLASTIC OUTER RIGHT s UPSTREAM BARRIER STRUCTURE SHEET 2
GENERAL I l90F31 JOA ORIFICE ANTENNA PLASTIC OUTER BOTTOM s JDN-1-2-IS/S NAVIGATION LOCK VISITORS BUILDING PLANS s I B JDFl .109_E-001 E-001 GENERAL NOTES, LEGEND AND ABBREVIATIONS 2
I 200F31 JOA ORIFICE ANTENNA PLASTIC OUTER BOTTOM VIEWS FLAT 5 B JDN-1-2-1 S/6 NAVIGATION LOCK VISITORS BUILDING ELEVATIONS & SECTIONS s 1 21 OF31 JOA ORIFICE ANTENNA PLASTIC OUTER BOTTOM VIEWS AT FLOOR ANGLE s B JDF-1-0-3/2 SOUTH SHORE FISH LADDER-EXISTING GENERAL LAYOUT 5
JDFl.109_E-00.1 E-101 ELECTRICAL- SITE PLAN 2 I 22 OF 31 JDA ORIFICE ANTENNA PLASTIC OUTER TOP COVER s ELEVATION AND SECTIONS 1 23 OF 31 JOA ORIFICE ANTENNA PLASTIC OUTER LEFT COVER s
D JDF-1-0-3/3 SOUTH SHORE FISH LADDER-GENERAL LAYOUT SIDEWALK, CURBS, FENCES, ETC, s JDFJ.109_E-S01 E-501 TYPICAL DETAILS - TRANSCEIVER PANELS AND CAPACITOR 2 1 24 OF 31 JOA ORIFICE ANTENNA PLASTIC OUTER RIGHT COVER s c JDF-l-4-3/2S SOUTH SHORE FISH LADDER SECTION No. 9-CONCRETE OUTLINE I s d§ Bi - ENCLOSURES I 25 Of 31 JDAORIFICEANTENNA PLASTIC OUTER BOTTOM COVER s PLANS AND DETAILS z~ " " Z,.!. 0 " JDFl.109_E-60l E-601 PITTAG SYSTEM BLOCK DIAGRAM 2 I 26 OF 31 JOA ORIFICE ANTENNA PLASTIC INNER BOTTOM VIEWS ATFLOOR ANGLE s ~~ ~
B JDF-1-4-3/26 SOUTH SHORE FISH LADDER SECTION No. 9-CONCRETE OUTLINE II s z
CONDUIT COVER DIMENSIONS C)
1 27 OF 31 JOA ORIFICE ANTENNA s ELEVATION AND SECTIONS ~~ \J;;; ~ z
JDF1.109_E-701 E-701 CONDUIT SCHEDULE 2 I 28 OF 31 JOA ORIFICE ANTENNA CONDUIT COVER EXTERIOR SHAPE DETAIL s ~ g, c JDF-1-4-3/31 SOUTH SHORE FISH LADDER SECTION No. 10-CONCRETE OUTLINE s if' 8 ~ 1 29 Of 31 JOA ORIFICE ANTENNA CONDUIT COVER VIEWS s
PLANS, ELEVATION AND SECTIONS
ilo 0
1 30 Of 31 JOA ORIFICE ANTENNA ELECTRONICS BOX VIEW'S s >-NORTH ADULT FISH LADDER B JDF-1-4-3/3S SOUTH SHORE FISH LADDER SECTION No. 11-CONCRETE OUTLINE s i~ ~ ill~ JDFl.109_EN101 ENIOl ELECTRICAL PLAN 2 1 31 OF31 JOA ORIFICE ANTENNA ELECTRONICS BOX VIEWS s '<
PLANS, ELEVATION AND SECTIONS ~
~~' ~; ti TRANSCEIVER PANEL INSTALLATION - PLAN AND SECTIONS 2 OVERFLOW ANTENNA SHEETS, (31) SHEETS D JDF-1-4-3/40 SOUTH SHORE FISH LADDER SECTION No. 12-CONCRETE OUTLINE s
I! ~ ~~ JD Fl .109_EN401 EN401 PLANS, SECTIONS AND ELEVATION ii - 1 I OF31 JDA OVERFLOW ANTENNA OVERVIEW s fil ii§l 2 1 20F31 JOA OVERFLOW ANTENNA LEFT ANTENNA ASSEMBLED s B JDF-1-4-3/4S SOUTH SHORE FISH LADDER SECTION Nos. 13 AND 14-CONCRETE OUTLINE s z
~~ "' g/~ JD Fl .109_EN402 EN402 TRANSCEIVER PANEL INSTALLATION - SECTION AND ISOMETRIC VIEWS PLANS, SECTIONS AND ELEVATION fil"' 21il I-
1 3 OF31 JOA OVERFLOW ANTENNA OVERFLOW ANTENNA- EXPLODED VIFW s gi'i g_ 4 OF31 JDA OVERFLOW ANTENNA ORDER OF ASSEMBLY - A s o~ o& .,, (L..;! .,::;
B SOUTH ADULT FISH LADDER 1
~ 1 S OF31 JOA OVERFLOW ANTENNA ORDER Of ASSEMBLY - B s
JDFl.109_ES101 ESlOl ELECTRICAL PLAN 2 Ill 1 60F31 JOA OVERFLOW ANTENNA ORDER Of ASSEMBLY - C s
~t55 TRANSCEIVER PANEL INSTALLATION - PLAN AND SECTIONS 2 1 7 OF31 )DA OVERFLOW ANTENNA ORDER OF ASSEMBLY - D s
JDFJ.109_ES40 I ES401 z ~ Cl I 8 OF31 JOA OVERFLOW ANTENNA CONDUIT COVER (LEffi s ~~~
2 1 9 OF31 JOA OVERFLOW ANTENNA SHIELD - LEFT ANTENNA s NOTES: JDFl .109_ESl 02 E5402 TRANSCEIVER PANEL INSTALLATION -SECTION AND ISOMETRIC VIEl'IS & D 0 1 100F31 JOA OVERFLOW ANTENNA SHIELD DOWNSTREAM FACE (LEFT) s
1 11 OF 31 JDA OVERFLOW ANTENNA SHIELD UPSTREAM FACE (LEffi s 1. SHEET ACTION NUMBER IDENTIFICATION KEY SHALL BE AS SHOWN BELOW: 8g~ 1 120f31 JOA OVERFLOW ANTENNA SHIELD OUTSIDE WALL (LEFn s ~ !\'. ~ 1 130F31 JOA OVERFLOW ANTENNA SHIELD INSIDE WALL (LEFl) s 1 DENOTES FIO DRAWING IS OBSOLETE AT THE COMPLETION OF 1 14 OF31 JOA OVERFLOW ANTENNA SHIELD FLEX RING (LEffi & GND LUG s THIS CONTRACT <Ii 1 ISOF31 JDA OVERFLOW ANTENNA SHIELD DETAILS (LEffi s ::>
- 1 160F31 JOA OVERFLOW ANTENNA PLASTIC BOTTOM TIIROUGH BOLT (LEffi s 2 DENOTES DRAWING SHALL BE UPDATED ATTHE COMPLETION 1 l70F31 JDA OVERFLOW ANTENNA PLASTIC BOTTOM THROUGH BOLT COVER (LEffi s OF THIS CONTRACT BY THE CONTRACTOR 1 l80f 31 JDA OVERFLOW ANTENNA PLASTIC SIDE THRU BOLT s 1 190F31 JOA OVERFLOW ANTENNA PLASTIC RIGHTSIDETHRU BOLT COVER s 3 DENOTES FIO DRAWING WILL BE SUPERCEDED BY THE FOLLOWING 2 1 20 Of 31 JOA OVERFLOW ANTENNA PLASTIC LEFT SIDE THRU BOLT COVER s DRAWINGS AT THE COMPLETION OF THIS CONTRACT i3 ffi <t:
I 21Of31 )DA OVERFLOW ANTENNA PLASTIC DOWNSTREAM FACE FERRITE (LEffi - A s CIOZz I 22 Of 31 )DA OVERFLOW ANTENNA PLASTIC DOWNSTREAM FACE FERRITE (LEffi - B s 4 DENOTES FIO DRAWING WAS REFERENCED BY THE FOLLOWING zozo @ 1 23 OF 31 )DA OVERFl.OW ANTENNA PLASTIC DOWNSTREAM FACE WIRE (LEFT) - A s CONTRACT DRAWINGS ~~~~ 0
1 24 OF 31 JOA OVERFLOW ANTENNA PLASTIC 001'/NSTREAM FACE WIRE (LEFT) - B s u:r:~ (!)
1 25 OF 31 JOA OVERFLOW ANTENNA PLASTIC UPSTREAM FACES (L&R) s 5 DENOTES FIO DRAWING IS FOR REFERENCE ONLY Q(/) -1 z 1 260F31 )DA OVERFLOW ANTENNA PLASTIC INTERNAL RIBS (L&R) s ...J[L~~ ~ 1 270F 31 )DA OVERFLOW ANTENNA PLASTIC CONNECTOR CAVITY PARTS (LOWER) s 2. FIO DENOTES "FOR INFORMATION ONLY" ~~I-'(/)
A Cl::J!::~ 0 1 28 OF 31 JOA OVERFLOW ANTENNA PLASTIC CONNECTOR CAVITY PARTS (UPPER) s zDO.
1 29 OF 31 JDA OVERFLOW ANTENNA PLASTIC CONNECTOR CAVITY DOOR (LEffi s 3. ALL SHEETS JN THE PLANS AND SPECIFICATIONS SET ARE INTENDED TO ;r:<t'.
1 30 OF 31 JOA OVERFLOW ANTENNA PLASTIC GALVANIC BARRIER(LEFT) s BE PRINTED IN COLOR 0 1 31OF31 JDA OVERFLOW ANTENNA FLEX PAL TE (LEffi s -, 4.) CONTRACT DRAWINGS AND FIO DRAWINGS ARE ON JOHN DAY
EXCITER CONDUIT SHEETS, (2) SHEETS "AS-CONSTRUCTED" HORIZONTAL AND VERTICAL CONTROL. SEE FIO
1 1 oFi JOA EXCITER CONDUIT PLAN CONDUIT ROUTE s DRAWING JDG-1-0-1/29 CONSTRUCTION BASELINE LAYOUT HORIZONTAL 1 2 OF2 JDA EXCITER CONDUIT PLAN ANTENNA CONDUIT DETAIL s AND VERTICAL CONTROL.
SHEET
IDENTIFICATION
G-001
DRAWING PLOT SIZE: ANSI D I DATE AND TIME PLOTIED: 912112016 1:33:10 PM I I BY USERNAME: G2ecdjem I SHEET NN~E: G-001
D c
B
A
I
LEGEND:
1. DETAILING CONVENTION SHALL BE INTERPRETED AS SHOWN BELOW:
FOR DETAILS ## IDENTIFICATION
NUMERIC VALUE ~DETAIL
• X-S## SYMBOL
•WHEN A DASH ,, ,, , --·1 SHEET NUMBER ON
' • ' /' / WHICH DETAIL
CHARACTER IS USED, \ ,/ APPEARS*
DETAIL APPEARS ON ___ ,..
THE SAME SHEET AS
ITWASTAKEN fTiiA DETAIL
\CSe/ SCALE: NONE
-"----_SHEET NUMBER
WHERE DETAIL
WAS TAKEN*
2. SECTIONING CONVENTION SHALL BE INTERPRETED AS SHOWN BELOW:
FOR SECTIONS IDENTIFICATION
ALPHAVALUE,VSECTION
SYMBOL
*WHEN A DASH,"·", ~SHEET IDENTIFICATION
CHARACTER IS USED, ON WHICH SECTION
SECTION APPEARS ON APPEARS *
THE SAME SHEET AS IT
WAS TAKEN !XX\ SECTION
3. SHEET IDENTIFICATION CONVENTION SHALL BE INTERPRETED AS SHOWN BELOW:
SA302
DISCIPLINE (SEE NOTE 7) J T TL SEQUENCE NUMBER (00 THRU 99)
AREA FEATURE - TYPE DESIGNATOR (SEE NOTE 6)
(SEE NOTES SAND 9)
4. SHEET FILE NAME CONVENTION SHALL BE INTERPRETED AS SHOWN BELOW:
JDF1.109_G-102XXX.DGN
PROJECTCODE Till~~T LFILEEXTENSION (JD =JOHN DAY) J l__: USER DEFINED(3 CHARACTERS ONLY;
MAJOR PROJECT FEATURE USE "X" FOR UNUSED SPACES)
(F =FISH PASSAGE) SEQUENCE NUMBER (00 THRU 99)
SERIES CODE SHEET TYPE (SEE NOTE 6)
(ASSIGNED BY GADD MANAGEMENT) AREA FEATURE (SEE NOTES 8 AND 9)
UNDERSCORE SYMBOL, "...'' DISCIPLINE (SEE NOTE 7)
5. MODEL FILE NAME CONVENTION SHALL BE INTERPRETED AS SHOWN BELOW:
PROJECT coDE __JJF~~Tzzzzzzzzzzz~-G~-J~DT 'T,ILE EXTENSION
(JD= JOHN DAY) l_.....= USER DEFINED(4 CHARACTERS ONLY;
MAJOR PROJECT FEATURE USE "X" FOR UNUSED SPACES)
(F = FISH PASSAGE) MODEL FILE TYPE (3D OR 2D)
SERIES CODE DASH SEPARATOR, "·"(REQUIRED)
(ASSIGNED BY GADD MANAGEMENT) DISCIPLINE (SEE LEGEND NOTE 7)
MODEL DESCRIPTION (USER DEFINED) UNDERSCORE SYMBOL,''...:'
(11) CHARCTERS MAX. OMIT IF NOT USED
DRAWING PLOT SIZE: ANSI D I DATE AND TIME PLOTIED: 9119/2016 4:44:40 PM
I
6. TYPE DESIGNATOR FOR SHEET IDENTIFICATION SHALL BE AS
SHOWN BELOW:
0 DENOTES GENERAL
1 DENOTES PLANS
2 DENOTES ELEVATIONS
3 DENOTES SECTIONS
4 DENOTES ENLARGED VIEWS
5 DENOTES DETAILS
6 DENOTES SCHEDULES AND SCHEMATICS
7 DENOTES REINFORCEMENT (USER DEFINED)
8 DENOTES USER DEFINED
9 DENOTES 3DVIEWS
7. ENGINEERING DISCIPLINE DESIGNATOR FOR SHEET IDENTIFICATION
SHALL BE AS SHOWN BELOW:
G DENOTES GENERAL
A DENOTES ARCHITECTURAL
C DENOTES CIVIL
L DENOTES LANDSCAPE
S DENOTES STRUCTURAL
M DENOTES MECHANICAL
E DENOTES ELECTRICAL
I
8. STRUCTURAL AREA FEATURE DESIGNATOR FOR "S" AND "A" SHEETS IDENTIFICATION
SHALL BE AS SHOWN BELOW:
• DENOTES GENERAL FEATURES
N DENOTES NORTH FISH LADDER STRUCTURE
S DENOTES SOUTH FISH LADDER STRUCTURE
9. ELECTRICAL AREA FEATURE DESIGNATOR FOR "E" SHEETS IDENTIFICATION
SHALL BE AS SHOWN BELOW:
N s
DENOTES GENERAL FEATURES (OR "ALL SHEETS ARE ELECTRICAL")
DENOTES NORTH FISH LADDER STRUCTURE
DENOTES SOUTH FISH LADDER STRUCTURE
I I BY USERNAME: G2ecdjem
I
GENERAL NOTES:
1. SEE SHEETS G-001 FOR DRAWING INDEX
2, SEE SHEET S-001 FOR STRUCTURAL GENERAL NOTES.
3. SEE SHEET E-001 FOR ELECTRICAL LEGEND, AND
ABBREVIATIONS AND GENERAL NOTES
I SHEETNAME: G-0-02
US Army Corps of Engineers" POfUl.AflD DISTRICT
SHEET
IDENTIFICATION
G-002 c
B
A
PROJECT SITE MAP
SCALE: NONE
DRAWING PLOT SIZE: ANSI D DATE AND TIME PLOTIED: 9/19/2016 4:46:07 PM
JOHN DAY DAM
.... ,,.1 ,.._.,,.,,.
1'
POWERHOUSE
BY USERNAME: G2ecdjem
DISTRICT BOUNDARY MAP
z w
LL
n.
10010203-040 - -~~LES
WASHINGTON
OREGON
51) I
US Army Corps ofEnglneors:ii P<)RTl.AND DISTRJCT
SHEET
G-003 c
B
A
I
GENERAL STRUCTURAL NOTES:
1. SCOPE
1.1 THESE GENERAL STRUCTURAL NOTES COVER STRUCTURAL
FEATURES OF THE JOHN DAY ADULT FISH LADDER PIT TAG
ANTENNA INSTALLATION FOUND ON THE "S" SERIES
DRAWINGS.
1.2 THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED
OTHERWISE ON DRAWINGS,
2.CONCRETE
2.1 ALL EXPOSED EDGES AND CORNERS OF CONCRETE SHALL
HAVE%" CHAMFERS UNLESS OTHERWISE NOTED. THIS SHALL
INCLUDE CORNERS OF ABUTIING CONTRACTION,
CONSTRUCTION, AND EXPANSION JOINTS BUT SHALL NOT
INCLUDE BLOCKOUTS FOR RAILS, GATE GUIDES, HANDRAIL
SOCKETS AND STAIR TREADS OR AS NOTED OTHERWISE
AND/OR MARKED N.C.
2.3 ALL RE-ENTRANT CORNERS SHALL HAVE 1" FILLETS EXCEPT AT
THE JUNCTION OF WALL AND FLOOR SURFACES WHERE FILLET
IS NOT CAST SIMULTANEOUSLY WITH ADJOINING MEMBER OR
AS NOTED OTHERWISE,
3. CONCRETE FINISHING
3.1 ALL SURFACES INSIDE THE FISH LADDER SHALL RECEIVE A
CLASS A FINISH AND BE SMOOTH TO THE TOUCH TO AVOID
INJURY TO FISH. ALL OTHER SURFACES SHALL RECEIVE A
CLASS C FINISH.
3,3 ANY DAMAGE TO THE CONCRETE FINISH DURING
CONSTRUCTION SHALL BE REPAIRED AS DESCRIBED IN THE
SPECIFICATIONS.
4. CONCRETE COVER
4.1 UNLESS NOTED OTHERWISE, THE MINIMUM COVER SHALL BE IN
ACCORDANCE WITH TABLE 1. THE MINIMUM COVER SHALL BE
THE CLEAR DISTANCE FROM THE EDGE OF THE
REINFORCEMENT TO THE EDGE OF THE CONCRETE.
4.2 IN NO CASE SHALL THE COVER BE LESS THAN 1.5 TIMES THE
NOMINAL MAXIMUM SIZE OF AGG~EGATE OR 2.5 TIMES THE
MAXIMUM DIAMETER OF REINFORCEMENT.
5. REINFORCEMENT
5.1 PREPARATION FOR PLACING DRAWINGS AND BAR BENDING
SCHEDULES SHALL BE IN ACCORDANCE WITH THE MOST
RECENT EDITION OF ACI 315,"MANUAL OF STANDARD PRACTICE
FOR DETAILING REINFORCED CONCRETE STRUCTURES".
REINFORCEMENT PLACEMENT DRAWING SHOWING LENGTH
AND LOCATIONS OF ALL SPLICES AND BAR BENDING
SCHEDULES NEED TO BE SUBMITIED TO THE GOVERNMENT
FOR APPROVAL.
5.2 ALL REINFORCEMENT STEEL SHALL CONFORM TO ASTM A 615,
GRADE 60 REQUIREMENTS.
5.3 UNLESS NOTED OTHERWISE, ALL HOOKS SHALL BE STANDARD
HOOKS AS DEFINED BY ACI 318-11. BAR SPLICE LOCATIONS
WILL BE DESIGNED BY THE CONTRACTOR AND SHOWN ON
SUBMITTALS.
5.4 BAR SPACING DIMENSIONS ARE MEASURED TO THE CENTERS
OF BARS.
5,5 A SYMBOL SUCH AS STAG. SPL. INDICATES REINFORCING
BARS TO BE STAGGER LAP SPLICED (CLASS B) BY
ALTERNATING LAP LOCATIONS AS SHOWN, AND PROVIDING THE
INDICATED LAP LENGTH.
5.6 A NOTATION SUCH AS 7'-6" J 1'·6" FOLLOWING THE BAR SIZE
AND SPACING INDICATES A BENT BAR WITH AN
OUTSIDE-TO-OUTSIDE DIMENSION (NOT BAR LENGTH) OF 7'-6". A
LEITER OR DIMENSION ON THE SHORT LEG INDICATES THE
FOLLOWING:
L: EXTEND BAR LAP SPLICE LENGTH BEYOND BEND
E: EXTEND BAR EMBEDMENT LENGTH BEYOND CROSSING
BAR
DIMENSION: OUTSIDE· TO-OUTSIDE LENGTH OF SHORT LEG
WHEN NO LETTER OR DIMENSION IS GIVEN, PROVIDE A
STANDARD 90' HOOK
I
5.7 ALL BARS SHALL BE SPACED AS SHOWN ON DRAWINGS.
5.8 REINFORCING BARS SHALL NOT CONTINUE ACROSS AN EXPANSION
OR CONTRACTION JOINT UNLESS SHOWN IN THE DRAWINGS. REBAR
SHALL CONTINUE ACROSS CONSTRUCTION JOINTS AS DETAILED IN
THE DRAWINGS.
5.9 VERTICAL REINFORCEMENT PROJECTING ABOVE THE FORMS SHALL
BE SUPPORTED TO PREVENT THE BREAKING OF BOND BETWEEN
THE REINFORCING BARS AND FRESHLY PLACED CONCRETE.
6. REINFORCEMENT TABLE (60 KSI), REFER TO TABLE 2.
6.1 DEVELOPMENT AND SPLICE LENGTHS FOR REINFORCING BARS
USED INTHIS CONTRACT SHALL BEAS DESCRIBED INACI 318·11
UNLESS NOTED OTHERWISE (UNO), AND ARE SHOWN IN THE TABLES.
6,2 THE TABLES PROVIDED ARE ONLY FOR FIELD INSPECTION
REFERENCE. ANY OMISSIONS OR VARIANCES FROM ACI SHALL NOT
BE CONSTRUED AS CHANGES IN THE ACI REQUIREMENTS.
6.3 TOP BARS ARE HORIZONTAL REINFORCEMENT SO PLACED THAT
MORE THAN 12 INCHES OF FRESH CONCRETE IS CAST IN THE
MEMBER BELOW THE DEVELOPMENT LENGTH OR SPLICE.
7.STRUCTURALSTEEL
7.1 ALL STRUCTURAL STEEL PLATES AND SHAPES WILL CONFORM TO
ASTM A 572 UNLESS OTHERISE NOTED IN THE DRAWINGS.
7.2 STRUCTURAL STEEL PIPE WILL CONFORM TO ASTM A53, GRADE B
ORASTM A500, GRADE B UNLESS NOTED OTHERWISE.
7.3 STRUCTURAL STEEL TUBING WILL CONFORM TO ASTM A500, GRADE
B.
7.4 STAINLESS STEEL SHAPES SHOWN ON THE DRAWINGS WILL
CONFORM TO AND TO ASTM A276 OR ASTM 240 TYPE 304L UNO.
STAINLESS STEEL TUBE WILL CONFORM TO ASTM A554.
7.5 GALVANIZING OF STEEL WILL CONFORM TO ASTM A123, UNLESS
OTHERWISE NOTED.
7.6 ALL CARBON STEEL BOLTS, NUTS, AND WASHERS USED FOR
STRUCTURAL STEEL CONNECTIONS SHALL BE OF THE MATERIAL,
GRADE, TYPE, CLASS, STYLE AND FINISH INDICATED BELOW UNLESS
NOTED OTHERWISE:
a. BOLTS - ASTM A325, TYPE 1, GALVANIZED
b. NUTS -ASTM A563, GRADE DH, TYPE 1, GALVANIZED
c. PLAIN WASHERS-ASTM F436, TYPE 1, GALVANIZED
7.7 WELDING SHALL CONFORM TO AWS CODES D1.1, D1.2, & D1.6 AS
APPLICABLE. WELDING THAT IS NOT SHOWN ON THE DRAWINGS
WILL NOT BE PERMITIED EXCEPT BY WRITTEN PERMISSION FROM
THE CONTRACTING OFFICER AND ENGINEER.
7.8 FIELD WELDING WILL NOT BE PERMITIED UNLESS SHOWN ON THE
DRAWINGS OR AUTHORIZED BY THE CONTRACTING OFFICER.
7.9 ALL WELDS SHALL BE CONTINUOUS UNLESS OTHERWISE NOTED.
EVERY ACCESSIBLE JOINT NOT HAVING A DESIGNATED TYPE AND
SIZE OF WELD SHALL BE SEAL WELDED PER AISC MINIMUM WELD
SIZE.
7.10ALL SHARP EDGES SHALL BE GROUND TO Afs" RADIUS MIN. UNO.
7 .11 GRIND ALL GROOVE WELDS SMOOTH SUCH THAT THERE ARE NO
BURRS, OFFSETS OR ROUGH AREAS. GRIND ALL WELDS ON
HANDRAILS SMOOTH SUCH THAT THERE ARE NO BURRS, OFFSETS
OR ROUGH AREAS.
7.12 ALL NEW HANDRAIL IS 1~" SCH 40 PIPE. ALL HANDRAIL POSTS
SHALL BE 1~" SCH 80 PIPE. ALL HANDRAIL MATERIAL SHALL BE
ASTM A53, TYPES, GRADE B (GALVANIZED).
7.13 WALKWAYS, HANDRAILS, STAIRS, LADDERS AND ALL APPLICABLE
CONNECTION DETAILS SHALL BE CONTRACTOR DESIGNED WHERE
CALLED OUT ON THE DRAWINGS AND SHALL MEET ALL
REQUIRMENTS SET FORTH IN THE LATEST EM 385-1·1 "SAFETY AND
HEALTH REQUIREMENTS MANUAL". SUBMIT ALL CALCULATIONS AND
DRAWINGS FOR GOVERNMENT APPROVAL AS CALLED OUT IN THE
SPECIFICATIONS.
7.14 GALVANIZE ALL WALKWAY STEEL. ALL GRATING TO BE SERRATED
OR ANTI-SKID BAR GRATING.
DRAWING PLOT SIZE: ANSI D I DATE AND TIME PLOTTED: 911912016 5:03:23 PM I
I
8. ALUMINIUM
8.1 ALL SHAPES, PLATES, AND BARS SHALL BE ALUMINUM ALLOY
6061-T6 MEETING REQUIREMENTS OFASTM B221.
8.2 WELDING OF ALUMINUM SHALL BE IN ACCORDANCE WITH
PROVISIONS OF AWS D1.2 WELDING CODE. NO FIELD WELDING WILL
BE PERMITTED UNLESS NOTED ON THE DRAWINGS OR AUTHORIZED
IN WRITING BY THE CONTRACTING OFFICER AND ENGINEER.
8.3 THE SYMBOL "G" SHOWN IN ALUMINUM WELD CALL OUTS MEANS
THAT THE DESIGNATED WELD JOINT SHALL BE A HAND SMOOTH
WELDED SURFACE THAT IS OBTAINED BY GRINDING, FORMING,
SANDING, POLISHING, ETC. DONE AS NECESSARY TO OBTAIN THE
SMOOTH JOINT.
8.4 ALL BOLTS, NUTS, AND WASHERS USED FOR STRUCTURAL
ALUMINUM CONNECTIONS SHALL BE OF THE MATERIAL, GRADE,
TYPE, CLASS, STYLE, AND FINISH INDICATED BELOW UNO:
a. BOLTS· ASTM A593, GROUP 1, COLD WORKED STAINLESS
STEEL.
b. NUTS • ASTM A594, GROUP 1, COLD WORKED STAINLESS STEEL.
c. PLAIN WASHERS· FABRICATE FROM MATERIAL CONFORMING
TO TYPE 304, TYPE 308, OR TYPE 316 THAT CONFORMS TO ASTM
A276 OR ASTM A240 STANDARDS.
9. EMBEDDED METALS
9.1 CONCRETE ANCHORS SHALL BE AS INDICATED IN THE DRAWINGS.
9.2 CONCRETE ANCHORS SHALL BE INSTALLED PER MANUFACTURERS
PUBLISHED WRITTEN RECOMMENDATIONS.
10. MISCELLANEOUS
10.1 GROUT SHALL BE AN EPOXY, NON SHRINK TYPE AS INDICATED IN
THE SPECIFICATIONS.
10.2 ALL GROUT USED FOR ANTENNA INSTALLATION SHALL HAVE 100%
BEARING AFTER PLACEMENT.
10.3 PLACE GROUT IN ACCORDANCE WITH THE MANUFACTURER'S
WRITTEN INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS.
DO NOT USE GROUT WHICH HAS BEGUN TO SET OR IF MORE THAN
ONE HOUR HAS ELAPSED AFTER INITIAL MIXING. FILL BLIND
CAVITIES BY PRESSURE INJECTION UNDER CONTROLLED VENTING.
10.4 PROTECT FRESHLY PLACED GROUT FROM PREMATURE DRYING AND .
EXCESSIVE COLD OR HOT TEMPERATURES. COMPLY WITH
MANUFACTURER'S REQUIREMENTS FOR COLD-WEATHER AND
HOT-WEATHER PROTECTION DURING CURING.
I BY USERNM1E: G2ecdjem
I
NOTES:
1.) SEE SHEET G-001 FOR DRAWING INDEX.
2.) SEE SHEET G-002 FOR GENERAL NOTES AND SYMBOLS ..
STRUCTURAL LEGEND:
1. MATERIAL PATTERNS SHALL BE AS SHOWN BELOW:
m DEMOLITION OF CONCRETE
i. DENOTES EXISTING CONCRETE
BJ!}~l DENOTES NEW CONCRETE
DENOTES STEEL AND OTHER METALS
ti/'.}J DENOTES GROUT
TABLE 1 - CONCRETE COVER
CONCRETE SECTION
UNFORMED SURFACES IN CONTACT WITH FOUNDATION
FORMED AND SCREEDED SURFACES EQUAL TO OR
GREATER THAN 24 INCHES IN THICKNESS;
#4 TO #11 BARS
FORMED AND SCREEDED SURFACES .GREATER THAN
12· AND LESS THAN 24" IN THICKNESS:
#4 TO #11 BARS
FORMED AND SCREEDED SURFACES EQUAL TO OR
LESS THAN 12 INCHES IN THICKNESS:
#4 TO #6 BARS
#7 TO #9 BARS
TABLE 2
MINIMUM CLEAR
COVER UNO,
INCHES
AC! 318-11 EQUATION 12-1
MINIMUM SPLICE AND DEVELOPMENT LENGTHS (JNCHESJ
MIX DESIGN 1 (f'c = 4500 PSI l
BAR SIZE TOP· BARS OTHER BARS
NUMBER DEVELOPMENT DEVELOPMENT
LENGTH LENGTH
TOP BAR
SPLICE
LENGTH
OTHER BARS
SPLICE
LENGTH
MINIMUM
HOOK
EMBED ME NT
LENGTH
3 12 12 14 12 4 14 12 19 14 5 1B 14 23 18 6 21 17 28 21 7 34 26 44 34 8 44 34 57 44 9 56 43 73 56
10 71 55 92 71 11 87 67 113 87
TABLE 2 IS GENERATED BASED ON EQUATION 12·1, SECTION 12.2,3 IN ACI 318·11.
LENGTHS IN TABLE 2 ARE BASED ON 4" CENTER TO CENTER SPACING AND FOR 2"
COVER.
FOR CLASS B TENSION LAP SPLICES, NORMAL WEIGHT CONCRETE,
COMPRESSIVE STRENGTH OF 4500 PSI, AND YIELD STRESS OF
60,000 PSI.
I SHEET NAME: S-001
US Army Corps of Engineers~
PORTWW DISTRICT
SHEET
S-001
A
DRAWING PLOT SIZE: ANSI D
EXIST NORTH FISH
LADDER WEIR 246
EXIST NORTH SHORE
FISH LADDER VISITORS
BUILDING
ISOMETRIC - PIT TAG ANNTENNA INSTALLATION ARRANGEMENT
DATE AND TIME PLOTIED: 911912016 5:04:55 PM
EXISTING FISH BARRIERS ARE NOT SHOWN FOR CLARITY
NOTTO SCALE
BY USERNAME: G2eodjem
NOTES:
1.) SEE SHEET G-001 FOR DRAWING INDEX.
2.) SEE SHEET G-002 FOR GENERAL NOTES AND SYMBOLS.
3.) SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES
AND SPECIFICATIONS.
4.) SEE SHEET SS502 FOR WEIR DEMOLITION AND
ANTENNA INSTALLATION NOTES.
5.) NORTH ARROW SHOWN IS LOCK AND DAM CONSTRUCTION
GRID NORTH SEE INFORMATIONAL DRAWINGS
6.) HANDRAIL SHOWN ONLY IN VICINITY OF TRANSCEIVER
PANELS WHERE IT WILL BE USED FOR SUPPORT.
7.) ALL WEIR AND ORIFICE ANTENNAS ARE GOVERNMENT
FURNISHED EQUIPMENT. SEE INFORMATIONAL DRAWINGS
FROM PACIFIC STATES MARINE FISHERIES COMMISSION.
SHEET NAME: SN001
US Army Corps of Engineers' PoRTlAND DISTRICT i
SHEET
IDENTIFICATION
SN001
B
A
DRAWING PLOT SIZE: ANSI D
NAVLOCK
BLOCl<No.21
5:
...J
Q lL ct'. w fl n
A n n v
I
L L
=> r
NAVLOCK
BLOCl<No.19
CONTRACTION JOINT
I
3'-~"
TYPE II TRANSCEIVER~
PANEL SUPPORTS. TYP
(4) PLACES.
r---i I
L L (0
C1i ---- ·-·-·-·- -----·-· o::----r r f fl /T
CONTRACTION JOINT
I
....___- NAVLOCKCHAMBER-__-
71 II
II 11
11111111 n I i
:=> i
- fn:'.-·----- --------
T \
7'·3~" 12\slM
~SIM
NAVLOCK
BLOCKNo.17
Ill
EXIST NORTH
SHORE FISH
LADDER
VISITORS BLDG
J r r
NAVLOCK
BLOCl<No.15
WATER FLOW
*N . PLAN - PIT TAG ANTENNA LOCATION ARRANGEMENT w EXISTING FISH BARRIERS ARE NOT SHOWN FOR CLARITY 1" = 1Q' .. Q"
I DATE AND TIME PLOTTED: 9119/2016 5:10:32 Pf.I I I BY USERNM1E: G2ecdjom
I
NOTES:
1.) SEE SHEET G-001 FOR DRAWING INDEX.
2.) SEE SHEET G-002 FOR GENERAL NOTES AND SYMBOLS.
3.) SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES
AND SPECIFICATIONS.
4.) SEE SHEET SS502 FOR WEIR DEMOLITION AND
ANTENNA INSTALLATION NOTES.
5.) NORTH ARROW SHOWN IS LOCK AND DAM CONSTRUCTION
GRID NORTH SEE INFORMATIONAL DRAWINGS
6.) DIMENSIONS SHOWN ARE FROM LADDER CONTRACTION
JOINT TO ii. OF TRANSCEIVER PANEL.
NAVLOCK
BLOCl<No.13
10' SCALE: l "= 1 O'
0 10'
I SHEETNAME: SN101
US Army cofps of Engineers s PORTlANO DISTRICT
SHEET
SN101
B
A
EXIST SOUTH SHORE
FISH LADDER VISITORS
BUILDING
EXIST SOUTH FISH -"=-.-
LADDER SUPPORT
COLUMN AND
FOUNDATION (TYP)
DRAWING PLOT SIZE: ANSI D
FUTURE ANTENNA
ELECTRICAL SERVICE
BUILDING (NOT IN
THIS CONTRACT)
EXIST FINISHED GRADE
DATEANDTIMEPLOTIEO: 911912016 5:12:52PM
EXIST SOUTH FISH
LADDER STRUCTURE
EXISTING RAILING ON
OUTSIDE OF LADDER
TYPE I TRANSCEIVER
PANEL SUPPORTS
(2 THIS SIDE)
EXIST BRIDGE OVER
LADDER SHOWN FOR
REFERENCE ONLY.
AS-BUILT INFORMATION
IS NOT AVAILABLE
ISOMETRIC - PIT TAG ANTENNA LOCATION ARRANGEMENT
EXISTING FISH BARRIERS ARE NOT SHOWN FOR CLARITY
NOTTO SCALE
BY USERNN,\E: G2ocdjem
EXIST SOUTH FISH
LADDER WEIR 184
NOTES:
1.) SEE SHEET G-001 FOR DRAWING INDEX.
2.) SEE SHEET G-002 FOR GENERAL NOTES AND SYMBOLS,
3.) SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES
AND SPECIFICATIONS.
4.) SEE SHEET SS502 FOR WEIR DEMOLITION AND
ANTENNA INSTALLATION NOTES,
5.) NORTH ARROW SHOW IS LOCK AND DAM CONSTRUCTION
GRID NORTH SEE INFORMATIONAL DRAWINGS
6.) HANDRAILS SHOWN ONLY IN VICINITY OF TRANSCEIVER
PANEL SUPPORTS,
7.) ALL WEIR AND ORIFICE ANTENNAS ARE GOVERNMENT
FURNISHED EQUIPMENT. SEE INFORMATIONAL DRAWINGS
FROM PACIFIC STATES MARINE FISHERIES COMMISSION.
WEIR CREST ANTENNA
SEE NOTE No,7 (TYP)
WEIR ORIFICE ANTENNA
SEE NOTE No.7 (TYP)
TYPE I TRANSCEIVER
PANEL SUPPORT
(2 THIS SIDE)
SHEET NAME: ssoot
WEIR CREST ANTENNA
SEE NOTE No.7 (TYP)
WEIR ORIFICE ANTENNA
SEE NOTE No.7 (TYP)
US Army Corps or Englneerse PoRTW-10 DISTRICT
SHEET
SS001
B
A
I wet:
O-u: ~ (/) lL :Jo
5' O"
REF REF
1------ --------·------ ·f------- --------ct: ct: ct:
l/j//;I I; i///I
WATER FLOW
RAMP SLOPE
FUTURE ANTENNA ----...
ELECTRICAL SERVICE °""-..
BUILDING, SEE NOTE
No.7 ON THIS SHEET.
I
60'·0" (REF)
LADDER SECTION 6
EXIST LOWER
SEGMENT OF FISH
LADDER (FS) (REF)
EXIST WALKWAY
TOC EL 185'-0"
f
>-EXIST OVERHEAD
SEGMENT OF FISH
LADDER SUPPORT
COLUMN (TYP)
I
5' 011
REF
10'-0"
REF
I
TYPEI~~
TYP ~ U':~i r!./ lLi :::>O, 11//.j,/I 1///1//1
I
10' .. 011
REF
PLAN - PIT TAG ANTENNA LOCATION ARRANGEMENT
DRAWING PLOT SIZE: ANSI D DATE AND TIME PLOTTED: 9/21/2016 11:26:47 M1
EXISTING FISH BARRIERS ARE NOT SHOWN FOR CLARITY
SCALE: 3/16" = 1 '-0"
BY USERNMIE: G2ecdjem
I i r-.
I i i
10' 4"(+/·)
REF
i i i -i i i i i i i i i i i i i i i
NOTES:
1.) SEE SHEET G-001 FOR DRAWING INDEX.
2.) SEE SHEET G-002 FOR GENERAL NOTES AND SYMBOLS,
3.) SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES
· AND SPECIFICATIONS.
4.) SEE SHEET SS502 FOR WEIR DEMOLITION AND
ANTENNA INSTALLATION NOTES.
5.) NORTH ARROW SHOW IS LOCK AND DAM CONSTRUCTION
GRID NORTH SEE INFORMATIONAL DRAWINGS
6.) HANDRAILS SHOWN ONLY IN VICINITY OF TRANSCEIVER
PANELS.
7.) ANTENNA ELECTRICAL SERVICE BUILDING NOT IN THIS
CONTRACT.
SCALE: o/i5"~ 1 '-0" 12"0 5' 10'
(,JI I I 1 I I
SHEET NAME: 88101
US Army Corps of Engineers$
PORTIANO DISTRICT
SHEET
SS101
A
FISH
LADDER
FISH LADDER
6"
REF
RESTING POOL WALL;
GRIND THIS FACE TO
FIT ANTENNA IF
NECESSARY
NON-OVERFLOW WEIR
8"
2"CLR
REF
oc ..Ju.. ow 1'I oc
OVERFLOW WEIR
PLAN - TYPICAL WEIR DEMOLITION (8 PLACES)
SCALE: 1" = 1 '-0"
(5) SPACES@ 1'-0" EA= 5'-0"
REF
NON-OVERFLOW WEIR
SOUTH SHORE LADDER SHOWN, NORTH LADDER SIMILAR
REINFORCEMENT SHOWN FOR INFORMATION ONLY
WEIR IS SYMETRICAL ABOUT CENTERLINE OF LADDER
I I I I I
!l
611 6"
REF REF
: \ I l ' ......... J ........ / I I
(5) SPACES@ 1"-0" EA= 5'-0"
REF
DASHED LINES INDICATE
EXIST REBAR TO BE
REMOVED BY CUT
-------------- ' I I I I
: EXIST WEIR l
! ORIFICE (TYP) !
I I i I I
I I I I -------- -------- _______ _J _____ L ___ -- ---4---,__--+!--- -- -------- ----------- ______________________________________ ]- ---t _________ L L __ -------------------------
MIDDLE ORIFICE
COVERED BY PLATE;
NO MODIFICATIONS TO
THIS PORTION OF WEIR
A ELEVATION - TYPICAL WEIR DEMOLITION (8 PLACES)
SCALE: 1" = 1 '-0" SOUTH SHORE LADDER SHOWN, NORTH LADDER SIMILAR
REINFORCEMENT SHOWN FOR INFORMATION ONLY
WEIR IS SYMETRICAL ABOUT CENTERLINE OF LADDER
' ~ co 0
DRILL REBAR 1" DEEP AND
PACI< WITH GROUT
s DETAIL OF CUT REBAR END
SCALE: 3" = 1 '-0" REQ'D ONLY AT RESTING POOL
WALL; OTHER BARS WILL BE
COVERED BY GROUT LAYER
UNDER ANTENNA
WATER FLOW
CONCRETE TO
BE REMOVED
BARS SHOWN ARE THE
HOOKED BARS IN THE
NON-OVERFLOW PORTION
OF THE LADDER WEIR.
CONCRETE TO
BE REMOVED
11-0''
NOTES:
1.) SEE SHEET G-001 FOR DRAWING INDEX.
2.) SEE SHEET G-002 FOR GENERAL NOTES AND SYMBOLS.
3.) SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES
AND SPECIFICATIONS.
4.) NORTH ARROW SHOWN IS LOCI< AND DAM CONSTRUCTION
GRID NORTH. SEE INFORMATIONAL DRAWINGS
5,) BARS ARE SHOWN AT LOCATIONS FROM ORIGINAL
CONSTRUCTION DOCUMENTS. THIS DOES NOT ACCOUNT
FOR EITHER CONSTRUCTION TOLERANCES OR ERRORS
IN BAR PLACEMENT. ACI 117 TOLERANCES ARE: -3/8" IN
BAR CLEARANCE FROM FACE, AND ±3" LATERALLY FROM
DECLARED POSITION
6.) EXISTING REINFORCEMENT BARS NOT EXPECTED TO BE A
FACTOR IN ANTENNA INSTALLATION ARE NOT SHOWN
7.) DIMENSIONS SHOWN ARE SPACING O.C., UNLESS
DECLARED AS "CLEAR", WHERE THE DIMENSION GIVEN
IS FROM FACE OF CONCRETE TO FACE OF BAR.
2"CLR
REF
SCALE: 1 "= l '-0"
12" 6" 0 1' EB SECTION LOOKING THRU WEIR
- SCALE: 1" = 1 '-0"
NOTE: REINFORCEMENT SHOWN FOR
INFORMATION ONLY
11111.!1111.! I
SCALE: 3"= 1 '-0"
3t1 511 12"
US Army Corps of Englneers 4
PORTI.AND DISTRICT
SHEET
SS501
B
A
ALL DIMENSIONS ARE
FROM THE D/S EDGE
OF THE ORIFICE, AND
ARE SYMMETRICAL
ABOUT ORIFICE rt
I
CONCRETE TO
BE REMOVED
FROM INVERT
I _,,,. OF LADDER
I ONLY
:1r ~1r tr--:p.~~:~.:,~~~·~-*r~-~~-~~~~~·~A//~tl>1tl l'i.'°XY)( ~')("'\o!'ltY'l-
I
I 4 .. 4 .. '_} 32 16 . ~~ .. 4 ..
16 16 cf ORIFICE
WATER FLOW
K:> AFTER CUTS ARE Av
MADE ALL AROUND, ---~ ~-~-
BREAK OUT [LADDER INVERT
CONCRETE AND CHIP~~ BOTTOM TO
PARALLEL WITH
LADDER INVERT
er~;~;.~~~- THRU ORIFICE DEMO
S%~ .
SS502
I
I
ONCE GROUT HAS
CURED, PLACE
ANTENNAAND
MATCH DRILL FOR
ANCHORS; USE
CAULK COMPOUND
AT GAPS AROUND
ANTENNA BASE.
PLACE GROUT LAYER
TO SMOOTH BOTTOM
OF BLOCKOUT AND
BRING ANTENNA
BASE TO FLUSH WITH
FLOOR OF INVERT
(APPROX i": FIELD
.J
Q lL Cl'. w
I i
I r I rt ORIFICE
WATER FLOW
J v
VERIFY DIMENSION)
~I~ ~------~~l~ ~~~~-1 ~~\c.
Et~;,;;.~~·~· THRU ORIFICE INSTALL
SS502
SS503
r
I
I
NOTES:
1.) SEE SHEET G-001 FOR DRAWING INDEX .
2.) SEE SHEET G-002 FOR GENERAL NOTES AND
SYMBOLS.
3.) SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES
AND SPECIFICATIONS.
4.) NORTH ARROW SHOWN IS LOCK AND DAM
CONSTRUCTION GRID NORTH. SEE INFORMATIONAL
DRAWINGS.
5.) PROCEDURES BELOW HAVE BEEN DEVELOPED TO
ENSURE THAT A.) ALUMINUM SHIELD AROUND
OVERFLOW ANTENNA IS NOT ELECTRICALLY
CONNECTED TO REINFORCEMENT; B.) THAT ALL
SURFACES ARE SMOOTH AND AS CLOSE TO ORIGINAL
LINEA$ POSSIBLE TO AVOID INJURING FISH OR
CHANGING HYDRAULICS, CONTRACTOR IS INVITED TO
PROPOSE FOR APPROVAL ALTERNATE PROCEDURES
THAT MEET THESE ENDS.
DEMOLITION NOTES:
OVERFLOW ANTENNAS:
1.) FIELD VERIFY DIMENSIONS OF EACH WEIR AND
CORRESPONDING ANTENNA.
2.) FIELD VERIFY THE HEIGHT OF THE EXISTING
OVERFLOW WEIRS BEFORE BEGINNING DEMOLITION.
ON THE UPSTREAM SIDE OF THE WEIR, MEASURE THE
DISTANCE FROM THE FISH LADDER FLOOR TO THE
TOP OF THE OVERFLOW WEIR IN THREE LOCATIONS;
THE RIGHT SIDE OF WEIR, THE CENTER OF WEIR, AND
LEFT SIDE OF WEIR RECORD AND TABULATE ALL
MEASUREMENTS AND SUBMIT TO THE GOVERNMENT
FOR INFORMATIONAL PURPOSES.
3.) REMOVE 8" FROM TOP OF EACH WEIR. CUT THRU
WEIR MUST BE LEVEL IN BOTH DIRECTIONS.
4.) IF OVERFLOW IS NARROWER THAN ANTENNA, GRIND
CONCRETE FROM RESTING POOL WALL UNTIL
ANTENNA WILL CLEAR. THIS GRIND MUST BE
VERTICAL AND PERPENDICULAR TO THE U/S FACE OF
WEIR.
5.) DRILL OUT HORIZONTAL REINFORCEMENT ALONG TOP
OF OVERFLOW EXPOSED ON RESTING POOL WALL TO
A DEPTH OF 2 INCHES AND PACK WITH GROUT.
ORIFICE ANTENNAS:
1.) FIELD VERIFY DIMENSIONS OF ANTENNA BASE.
2.) MARK AND CUT INVERT OF LADDER. CUTOUT IN
CONCRETE MUST NOT BE MORE THAN t INCH LARGER
THAN BASE IN ANY PLAN DIMENSION TO FACILITATE
CAULKING DURING INSTALLATION. DEPTH MUST BE AT
LEASTi INCH GREATER THAN DEPTH OF ANTENNA
BASE.
I
INSTALLATION NOTES:
OVERFLOW ANTENNA:
1.) PLACE DRILL GUIDE INTO OVERFLOW. VERIFY THAT IT
CLEARS ALL AROUND AND FITS WITH MINIMUM CLEARANCE
ON WIDTH.
2.) IF WIDTH OF OVERFLOW DOES NOT MATCH DRILL GUIDE:
A.) IF OVERFLOW IS TOO NARROW, REMOVE
MATERIAL FROM VERTICAL WALL OF RESTING POOL UNTIL
DRILL GUIDE JUST CLEARS. (SEE SS501)
B.) IF OVERFLOW IS WIDER THAN DRILL GUIDE, PLACE
RESTING POOL SIDE OF DRILL GUIDE FLUSH SO ALL
CLEARANCE IS AT OUTSIDE WALL.
3.) SHIM UNTIL TOP OF DRILL GUIDE BASE PLATE IS LEVEL AND
7 INCHES BELOW TOP OF WEIR RECORDED BEFORE
DEMOLITION.
4.) MATCH DRILL HOLES FOR ANCHORS.
6.) HOLES HAVE BEEN LOCATED TO MISS ASSUMED
REINFORCEMENT LOCATIONS FROM ORIGINAL
CONSTRUCTION DRAWINGS. VERIFY THAT NO HOLE HAS
PENETRATED REINFORCEMENT; IF ANCHOR WILL BE IN
CONTACT WITH REINFORCEMENT, ABANDON HOLE AND
DRILL NEW HOLE 1-! INCH AWAY AFTER INSTALLATION OF
ANTENNA. NEGLECTING TO DO THIS MAY RESULT IN
FAILURE OF ANTENNA SYSTEM. REPAIR OR REPLACEMENT
WILL BE AT CONTRACTOR'S EXPENSE.
6.) REMOVE DRILL GUIDE AND INSTALL ANCHORS IAW
MANUFACTURER'S INSTRUCTIONS.
7.) COAT INSIDE OF ANTENNA SHIELD WITH BOND BREAKING
COMPOUND TO FACILITATE LATER REMOVAL FOR
MAINTENANCE.
8.) PLACE OVERFLOW ANTENNA AND SECURE. IF ANTENNA IS
NARROWER THAN OVERFLOW, ADJUST ANTENNA FLEX
PLATE AS NECESSARY TO FIT IAW ANTENNA INSTRUCTIONS.
9.) INJECT GROUT UNDER ANTENNA THRU HOLES PROVIDED;·
STRIKE OFF GROUT FLUSH WITH ANTENNA SHIELD AND
GIVE HOLES STEEL TROWEL FINISH.
10.)VERIFY ALL SURFACES THAT FISH MAY CONTACT ARE
SMOOTH TO THE TOUCH.
. ORIFICE ANTENNA:
I
1.) VERIFY REQUIRED THICKNESS OF GROUT TO BRING
ANTENNA BASE TO FLUSH WITH INVERT USING DRILL GUIDE.
2.) PLACE LAYER OF GROUT. AFTER CURING, VERIFY THAT
INVERT IS FLUSH WITH DRILL GUIDE AND THAT GUIDE DOES
NOT ROCK ON UNEVEN SURFACES.
3.) MATCH DRILL HOLES, REMOVE DRILL GUIDE, AND INSTALL
ANCHORS IAW MANUFACTURER'S INSTRUCTIONS.
4.) PLACE ANTENNA AND SECURE WITH BOLTS.
5.) CAULK ANY GAPS LEFT AROUND BASE WITH 3M HYBRID
ADHESIVE SEALANT FAST CURE 4000 UV WHITE, PN06580,
OR APPROVED EQUAL
SCALE: 3"= l '-0" ? r 6" • 1r '--'~~----'---'--'---'---_J
SCALE: 1 W= 1 '-0"
12" 9" 6" 3" 0 1' !,,!,,!11!11! I I I I
US Army Co1ps of Engineers~
PORTI.ANO DISTRICT
SHEET
SS502
B
A v v i
~FISH
c:"":J :9
LADDER ~ " u.
Q
<I> Cl'.
I I
~ I I
---' I I -1 5 I , ' I
NON-OVERFLOW WEIR
:Jk:) . - - -- - -- I
-------( r- -- ---- 'I
' II
,r
'\. • - • / OVERFLOW ANTENNA (TYP.)
<b. 4 v v
PLAN - TYPICAL LADDER WEIR INSTALLATION (8 PLACES)
SCALE: l" = 1'-0"
NON-OVERFLOW WEIR
I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I
I I
. SOUTH SHORE LADDER SHOWN, NORTH LADDER SIMILAR
WEIR IS SYMETRICALABOUT CENTERLINE OF LADDER
RED HEAD MULTI-SET 11112" SS104 ANCHORS
OR APPROVED. EQUIVALENT, WITH 3/8"-16UNC
HEX DRIVE FLAT SCREWS. (TYP)
21 PLACES ON OVERFLOW ANTENNA,
12 PLACES ON OUTSIDE WALL SHIELD
17 PLACES ON ORIFICE ANTENNA
VENT HOLES FOR GROUT (TYP.)
OVERFLOW ANTENNA
(SEE NOTE No.6)
ORIFICE ANTENNA
(SEE NOTE No.6)
I I I t-- --------------------------------------{::::: .. :::.-J-------+f+~---+----l+l-I i __ --------------------------------------J L ______ _
A ELEVATION LOOKING UPSTREAM
SCALE: 1" = 1 '-0" SOUTH SHORE LADDER SHOWN, NORTH LADDER SIMILAR
WEIR IS SYMETRICAL ABOUT CENTERLINE OF LADDER
v
_J
THIS SHIELD AND
ANTENNA BODY WILL BE
FLUSH AGAINST RESTING
POOL WALL AFTER
INSTALLATION.
ADJUSTMENT TO
ANTENNA LENGTH WILL
BE IN FLEX PLATE (SEE
ELEV. A AND NOTE No.6)
DRILL HOLES
FOR CONDUIT
AS NEEDED
FLEX PLATE FOR LENGTH ADJUSTMENT
WATER FLOW
NOTES:
1.) SEE SHEET G-001 FOR DRAWING INDEX.
2,) SEE SHEET G-002 FOR GENERAL NOTES AND SYMBOLS,
3.) SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES
AND SPECIFICATIONS.
4.) NORTH ARROW SHOWN IS LOCK AND DAM CONSTRUCTION
GRID NORTH. SEE INFORMATIONAL DRAWINGS
5.) SEE SHEET SS103 FOR INSTALLATION NOTES AND SEQUENCE.
6.) ALL WEIR AND ORIFICE ANTENNAS ARE GOVERNMENT
FURNISHED EQUIPMENT. SEE INFORMATIONAL DRAWINGS
FROM PACIFIC STATES MARINE FISHERIES COMMISSION.
GROUT UNDER ANTENNA AFTER
INSTALLATION WITH EPOXY TYPE
GROUT.
US Army Corps of Engfneersc PORTl.AND DISTRICT
SHEET
IDENTIFICATION
88503
B
A
ATTACH SUPERSTRUTW/
~"BOLTS AND CHANNEL
NUTS PER MFR
INSTRUCTIONS (TYP)
SUPERSTRUT
A-1200-HS_SS
WATER FLOW
CJP
LOCATE AND ATTACH
CAPACITOR ENCLOSURE
SUPERSTRUT SUPPORTS
AT INSTALLATION. MATCH
DRILL WITH HSS FOR
112"-UNC HEX HEAD
STAINLESS STEEL BOLTS
WITH FLAT WASHER AND
HEX NUT. (2) AT EACH
SUPERSTRUT SPPORT.
SEE ELECTRICAL SHEETS
~~~~~'! FISH~
SIDE - TYPE II SUPPORT
SCALE: 1" = 1 '-0" SEE NOTES No.5 AND No.6
' T""~CO ..
· '~· 2"
ATTACH PANELS
ACCORDING TO
ELECTRICAL SHEETS
CJP
2"x1~"x11 GA
ASTMA554
STAINLESS
STEEL TUBE
;\"U-BOLT
FOR2"0
STD PIPE
(TYP)
o/ ~· 4
J w 1-- 0 z w w ' T""clJ'>t
~\N '<j"
~JJCO _,
~ z w w
.1~ 2"
ATTACH PANELS
ACCORDING TO
ELECTRICAL SHEETS
o'. w 0 o'. 0 :) w
IL 0
0 :)
w IL D 0 (ij w
2"x 1;l"x11 GA ~ (ij
ASTMA554 0 ~ STAINLESS z :::> STEEL TUBE w 0
:I: (/) 1-- w z
~ 0 ...J z w 0 z ...J ti: w z :I: Ci:
~ !Q
:l @) :::>
@)ii: (i) w ~ n::
0 ~ .,..:.!,N(f)
'1lr"' lo
B D/S SUPPORT LEG
SCALE: 1 1 /2" = 1 '-0" SEE NOTES
No.5AND6 o'. w D
IL
w D (ij z td ~ a.
Ii b lo
114" PLATE
1/8
CUTU-BOLT
AS NEEDED
TO ATTACH
BOX. ONE
THREAD MUST
EXTEND
BEYOND FACE
OF NUT.
It---__ !rt---.---.. r _____ ,,.,___,__ ii I
II I
II I
II I
II I
II I
II I
II I
t'"~
;}"U-BOLT
FOR2"0
STD. PIPE.
(TYP)
CD~:~?.=~!? ET Al L
NOTE: TYPE I ONLY
WATER FLOW
SUPERSTRUT
.--J---ll-lt------:/-A-1200-HS_ss ffi Bl
D D
'.:? 0 ..
EXISTING HANDRAIL
W STD PIPE (TYP)
1L [ E:, Ii:' Ii:' w e;, w e;, .,..:.!,'<l"
.,..:cb"' ·'
NOTES:
1.) SEE SHEET G-001 FOR DRAWING INDEX.
2.) SEE SHEET G-002 FOR GENERAL NOTES AND SYMBOLS ..
3.) SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES
AND SPECIFICATIONS.
4.) NORTH ARROW SHOWN IS LOCK AND DAM CONSTRUCTION
GRID NORTH. SEE INFORMATIONAL DRAWINGS
5.) TYPE I SUPPORTS ARE USED IN (4) PLACES AT SOUTH SHORE
FISH LADDER ONLY. TYPE II SUPPORTS ARE USED IN (4)
PLACES AT NORTH SHORE FISH LADDER ONLY. SEE SHEETS
SS101 AND SN101.
6.) CONSTRUCTION OF TYPE II SUPPORTS SHOWN ON THIS SHEET
ARE FOR THOSE ON THE RIGHT SIDE OF THE CHANNEL. PANELS
ON THE LEFT SIDE OF THE CHANNEL ARE OPPOSITE HAND.
THERE ARE 2 RIGHT SIDE TYPE II SUPPORTS AND 2 LEFT SIDE
TYPE II SUPPORTS. SEE NOTE No.5, 7.) EXPANDED METAL PANELS BETWEEN HANDRAILS NOT SHOWN.
8.) THE SUPPORTS HAVE BEEN DESIGNED TO ACCEPT SUNSHADES
OVER PANELS. THESE SHADES ARE IN ANOTHER CONTRACT
AND ARE NOT SHOWN HERE.
9.) ALL METAL FABRICATIONS AND HARDWARE SHOWN ON THIS
SHEET ARE TYPE 304 STAINLESS STEEL.
10.) ADJUST SPACING BETWEEN HOLES FOR U-BOL TS ACCORDING
TO SPECIFIC MFR PRODUCT SELECTED.
.YB
) LOCATE AND ATTACH CAPACITOR
ENCLOSURE SUPPORTS AT
INSTALLATION SEE ELECTRICAL
SHEETS
SCALE: 6"= l '-0" 0 1" 2" 3"
SCALE: 1 W= 1 '-0"
1211 9" 611 311 0
1 .. 1 .. 1 .. 1 .. 1
SCALE: 1 "= 1 '-0"
12" 6' 0 1' l11t11!1111d I
6"
1' I
Us Army Corps of Englneersl!l
PORTLAND DISTRICT
SHEET
88504
G
B
A
-H-
-E-
-K-
DRAWING PLOT SIZE: ANSI D
GRAPHIC SYMBOLS
ELEVATION/SECTION REFERENCE
TOP LETTER INDICATES ELEVATION/SECTION
BOTTOM NO. INDICATES SHEET REFERENCED
DETAIL REFERENCE
TOP NO. INDICATES DETAIL
BOTTOM NO, INDICATES SHEET REFERENCED
CIRCUIT BREAKER
XXXA CURRENT RATING NOTED
OR MOTOR CIRCUIT PROTECTOR
XX/M MAG ONLY RATING SHOWN
LSI ELECTRONIC TRIP BREAKER
I
(L-LONG TIME, S- SHORT TIME, I-INST)
LSIG ELECTRONIC TRIP BREAKER
(L-LONG TIME, S- SHORT TIME, I-INST,
G-GROUNT FAULn
ELECTRICALLY-OPERATED, DRAWOUT TYPE,
METAL-CLAD CIRCUIT BREAKER
ELECTRICALLY-OPERA TED, DRAWOUT TYPE,
METAL ENCLOSED AIR CIRCUIT, NUMBER
INDICATES TRIP RATING IN AMPERES
MOLDED-CASE CIRCUIT BREAKER, NUMBER
INDICATES TRIP RATING IN AMPERES.
2P INDICATES 2-POLE
3P INDICATES 3-POLE
DISCONNECT SWITCH
VOLTAGE OR CONTROL TRANSFORMER
POWER TRANSFORMER (ONE LINE DIAGRAM)
#INDICATES KVA RATING
OVERLOAD RELAY
FUSE
CONTACTS (NC)} IN DE-ENERGIZED POSITION
OR WHEN QUANTITIES TO
CONTACTS (NO) WHICH THEY RESPOND ARE
OF THE LOWEST VALUE
PUSH TO TEST INDICATING LIGHT
(A=AMBER,G=GREEN,R=RED, W=WHITE,
Y=YELLOW, B"'BLUE, ETC.)
MOTOR
#INDICATES APPROX HP RATING
CONNECTION TO GROUND BUS
INTERLOCK (ELECTRICAL)
INTERLOCK (MECHANICAL OR KEY)
JUNCTION BOX
480V RECEPTACLE
240V RECEPTACLE
125V, 20A DUPLEX RECEPTACLE
l 25V, 20A DUPLEX RECEPTACLE (CEILING BOX)
SINGLE-POLE, SINGLE-THROW (SPsn SWITCH
SINGLE POLE SNAP SWITCH, 12SV, 20A
3-WAY SNAP SWITCH, 125V, 20A
NEW POWER CIRCUIT IDENTIFICATION
PER SCHEDULE
NEW CONTROL CIRCUIT IDENTIFICATION
PER SCHEDULE
NEW MATERIAL IDENTIFICATION
PER LIST
TRANSIENT SUPPRESSOR
NON-FUSED HP RATED DISCONNECT SWITCH
FUSED HP RATED DISCONNECT SWITCH
COMBINATION MOTOR STARTER
(NUMBER INDICATES NEMA SIZE RATING)
MANUAL MOTOR STARTER
VFD
INTEGRAL MOTOR STARTER
o.l.D
_l_ 0 0
GRAPHIC SYMBOLS (CONT.)
TEMPERATURE SWITCH
(N.O., CLOSES ON DROPPING TEMPERATURE)
LIMIT SWITCH (N.C.)
LIMIT SWITCH (N.O.)
N.C. PUSH BUTTON
N.O. PUSH BUTTON
3-POLE DISCONNECT SWITCH,
EXTERNALLY OPERATED
(NUMBER INDICATES AMP RATING)
DISCONNECTING DEVICE
(BUS STAB, PLUG/RECEPT, ETC.)
SAMPLE DEVICE FUNCTIONS
@ CONTROL RELAY
@ AC CONTACTOR
EXAMPLES
-'- OLX OR foL\ T \V
¢42-1 OR®
SUFFIX X INDICATES ASSOCIATED
AUXILIARY RELAY.
SUFFIX USED FOR IDENTIFICATION.
CONDUIT EXPOSED
I o--
CONDUIT EMBEDDED IN FLOOR OR WALL
CONDUIT TURNING TOWARD OBSERVER.
CONDUIT TURNING AWAY FROM OBSERVER.
EMBEDDED GROUND CONDUCTOR
(SIZE AS INDICATED).
o. J,11- - - - GROUND INSERT IN FLOOR
[---- CONDUIT CAPPED OFF
CONDUIT AND CABLE l.D.
- ALUMINUM OR BRASS MARKER PLATE
3.5" LX 0.53" H WITH l /4 "(MIN.)
ENGRAVED LETTERING
hoNDUIT l.D AND SIZE
(SEE NOMENCLATURE, THIS SHEET)
SECURE TO CONDUIT WITH EITHER
ALUMINUM OR NYLON STRAPS
EXPOSED CONDUITS
-VINYL (SELF-LAMINATING) TAG
4" L X 0.5'' H WITH 1 /4" (MIN.)
LETTERING. SECURE TO CABLE WITH
NYLON STRAPS
\CIRCUIT l.D.
\(SEE NOMENCLATURE, THIS SHEET)
SUA-Q1 -CQA3 11tl ~ 3#1 /?' 1#8 EGC w n
!NUMBER & SIZE OF CONDUCTORS
OR CABLE
MUTLl-CONDUCTOR CABLES AND BUNDLES
(WITHIN BOXES, ENCLOSURES, AND PANELS)
I DATEANDTIMEPLOTTED: 9121/2016 9:16:06AM t
NOMENCLATURE
A. TERMINAL EQUIPMENT
L -LOCK
F - FISH RELATED
D - NON-OVERFLOW DAM
1. SWITCHBOARDS AND SWITCHGEAR
LCQ -480V SWITCHGEAR (NAY LOCK)
SU - 480V SWITCHBOARD ~MAIN UNITS)
SUA -480V SWITCHBOARD FISHWATER UNITS)
SJ -13.BkV SWITCHGEAR STATION SERVICE)
2. LOAD CENTERS
DCRl -480V DAM LIGHTING)
CQ - 480V !POWERHOUSE)
DQ - 480V NON-OVERFLOW DAM)
FCQ - 480V FISH RELATED)
SQ - 480V SUBSTATION (POWERHOUSE)
3. APPARATUS
B - BATTERY
CT - CURRENT TRANSFORMER
)OR - REMOTE PLC INPUT/OUTPUT RACK
L - LIGHTING
M - MOTOR
MCC - MOTOR CONTROL CENTER
T - TRANSFORMER (POWER)
TR - TRANSFORMER (LIGHTING)
X - BREAKER (ADD VOLTAGE LETTER)
Z - DISC. SWITCH (ADD VOLTAGE LETTER)
B. MODIFYING TERMS FOR TERMINAL EQUIPMENT
1. AS AN AID TO FURTHER IDENTIFICATION OF
VOLTAGE CLASS AND LOCATION OF THE
EQUIPMENT, THE FOLLOWING ARE APPLIED TO
SEPARATELY MOUNTED BREAKERS, DISCONNECT
ING MOUNTED BREAKERS, DISCONNECTING
SWITCHES, CURRENT TRANSFORMER AND
VOLTAGE TRANSFORMERS.
J - 13.8kV P - SkV Q -480V R - 120/240 (120/208) .
N - NEUTRAL (I.e. GNl ,TNl)
2. SERVICE CODE OR VOLTAGE CLASS
c - CONTROL CIRCUITS d - 0-48V AC/DC f - FIBER OPTIC CIRCUITS J - POWER CIRCUIT, 13.8kVAC p - POWER CIRCUIT, 4160VAC q - POWER CIRCUIT, 480VAC r - POWER CIRCUIT (120/240 OR 120/208 VAC) s - SPARE CONDUIT tn - LOCAL AREA NETWORK (LAN) CIRCUITS tt - TELEPHONE/PBX CIRCUITS, COMM CIRCUITS T1 - DEDICATED Tl CIRCUITS
U - ALARM CIRCUITS, ANNUNCIATOR CIRCUITS,
AND OTHER LOW-LEVEL SIGNAL CIRCUITS.
C. CIRCUIT AND ROUTING IDENTIFICATION
1. ELECTRICAL CIRCUITS AND CONDUITS ARE
IDENTIFIED AS FOLLOWS:
A. BETWEEN MAJOR ITEMS OF EQUIPMENT,
A THREE PART NUMBER IS USED.
START OF RUN -------- ,-ENO OF RUN
DQl-ql-MTSl ~~~m~ gm5oR __; '-crncun NUMBER
B. A TWO-PART NUMBER IS USED FOR MOST
LIGHTING AND SOME POWER DISTRIBUTION
CIRCUITS; I.E., THE END OF RUN IS OMITTED.
C. CONTROL CIRCUIT NUMBERS CORRESPOND TO
THE NUMBER OF THE CONTROLLED POWER
CIRCUIT; e.g. CQA3-cl WOULD CONTROL CQA3-ql.
D, CONDUIT NUMBERS ARE GENERALLY IDENTICAL
TO THE CIRCUIT CONTAINED WITHIN THE
CONDUIT.
E. CIRCUITS TO DEVICES FORMING AN INTEGRAL
PART OF TERMINAL EQUIPMENT RECEIVE THE
TERMINAL EQUIPMENT DESIGNATION (e.g. THE
CIRCUIT TO CT'S IN CIRCUIT BREAKER XJ 1
COULD BE DESIGNATED SU1-q1-XJ1). CIRCUITS
TO SEPARATELY MOUNTED DEVICES RECEIVE
THE DESIGNATION ASSIGNED TO THE DEVICE
(I.e. CQ24-ql-4C1 IS A CIRCUIT GOING TO TRANS. OIL PUMP 4Cl ).
2. MULTI-CONDUCTOR CABLES ARE IDENTIFIED
BY SUFFIX "C"; I.e., 3/C INDICATES A
THREE-CONDUCTOR CABLE WHILE A NUMERAL
3 INDICATES THREE CONDUCTORS.
D. FIBER OPTIC CABLE IDENTIFICATION
Pfl -4/f-M[XX ORIGIN__JJ LDEST!NATION 1xx =#OF
THE PANELi
NO. OF FIBERS MODE (SM FOR SINGLE MODE•
MM FOR MULTI -MODE I
I
A
AF
AFF
AFG
AIC
AIR
AL
AT
ATS
AWG
BCG
BK
c
CB
CKT
CGB
CL
CPT
CPU
cs
CT
CV
DIV
DIS
ECC
EF
EL
EM
EXST
F,FU
FCB
FDR
FDX
FLR
FLUOR
F/O
FVNR
FVR
G/GND
GALV
GFCI
GFCIP
GFE
GI
HDX
HH
HID
HTR
IG
INCAND
INST
J/JB
L
LC
LT-FLEX
LTG.
LR
L/R
LSI
M/MTR
MCB
MCC
MCP
MD
MH
MLO
MM
MS
MPC
MTS
N
NA
NC
NO
NP
OL
PART
PB
PC
PDB
PH
PIT
PNL
PR
PS
PTT
PVC
RCPT
REF
RGS
RN
SA
SF
SM
S/N
SPD
SPDT
SPST
SS
TB
TC
TR
TYP
UG
UH
UIS
UPS
v
VFD
VM
vs w
WP
WT
'ftvR
XFMR
ELECTRICAL ABBREVIATIONS
~~~ru~~· ~~~~ii.ME
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMPERE INTERRUPTING CAPACITY
AMPERE INTERRUPTING RATING
ALUMINUM
AMPERE TRIP
AUTOMATIC TRANSFER SWITCH
AMERICAN WIRE GAUGE
BARE COPPER GROUND
BRAKE
~~EW~R~~~~
CIRCUIT
CABLE GLAND BUSHING
CURRENT LIMITING
CONTROL POWER XFMR
CENTRAL PROCESSING UNIT
COUNTING STATION
CABLE TRAY I CURRENT TRANSFORMER
CABLE VAULT
DIVISION
DOWNSTREAM
EQUIPMENT GROUNDING CONDUCTOR
EXHAUST FAN
ELEVATION
EMERGENCY
EXISTING
FUSE
FEEDER CIRCUIT BREAKER
FEEDER
FULL-DUPLEX
FLOOR
FLUORESCENT LIGHTING
FIBER OPTIC
FULL VOLTAGE NON-REVERSING
FULL VOLTAGE REVERSING
GROUND
GALVANIZED
GROUND FAULT CIRCUIT INTERRUPTER
GFCI PROTECTED
GOV'T FURNISHED EQUIPMENT
GROUND INSERT
HALF-DUPLEX
HAND HOLE
HIGH INTENSITY DISCHARGE
HEATER
ISOLATED GROUND
INCANDESCENT
INSTANTANEOUS
JUNCTION BOX
LOWER
LIGHT CONTACTOR
LIQUID TIGHT FLEX CONDUIT
LIGHTING
LATCHING RELAY
LOCAL/REMOTE
LONG-TIME, SHORT-TIME, INSTANTANEOUS
MOTOR
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MOTOR CIRCUIT PROTECTOR
MOTION DETECTOR
~~~Hmu OMNEi1AL HALIDE
MULTI MODE (FIBER)
MOTOR STARTER
MINI-POWER CENTER (XFMR AND PNL)
MANUAL TRANSFER SWITCH
NEUTRAL
N8~M~~[$~tJ~Ib NON-APPLICABLE
NORMALLY OPEN
NAMEPLATE
OPEN
OVERLOAD RELAY
PARTIAL
PULL BOX
PHOTOCELL
POWER DISTRIBUTION BLOCK
PHASE
PASSIVE INTEGRATED TRANSPONDER
PANEL
PAIR
PRESSURE SWITCH
PUSH TO TEST
POLYVINYL CHLORIDE CONDUIT
QUARTZ LIGHTING
RAISE
RECEPTACLE
REFERENCE INFORMATION
RIGID GALVANIZED STEEL CONDUIT
RUN
SURGE ARRESTOR
SUPPLY FAN
SINGLE MODE (FIBER)
SOLID NEUTRAL
SURGE PROTECTION DEVICE
SINGLE-POLE DOUBLE-THROW
SINGLE-POLE SINGLE-THROW
STAINLESS STEEL/ SOFT STARTER
TERMINAL BLOCK .
TERMINAL CABINET
TRIAD
TYPICAL
UNDERGROUND
UNIT HEATER
UPSTREAM
UNINTERRUPTIBLE POWER SUPPLY
VOLTS
VARIABLE FREQUENCY DRIVE
VOLTMETER
VOLTMETER SWITCH
WATT
WEATHERPROOF
WATERTIGHT
WITH
TRANSCEIVER
TRANSFORMER
t BY USERNMIE: G2ecdtxlb
I
CONTROL ABBREVIATIONS
Al
AIR
~6M/AH
AUX
AWS
CP
CR
cs cu
CV
BP
DI
DNET
DTAP
DO
DPM
DS
DSA
DT
ETM
FC
FM
FU
FWS
FZ
HOA
HMI
HY
1/0 l~p
IR
LC
LE
LS
LT
MCR
ME
MIT
PA
PB
PBL
PC
PDT
Pl
PL
PLC
PRY
PRX
PS
PT
PTT
PWR
PY
REG
RIO
RLS
RVSS
S/N
SCADA
SCR
~~L/SV
STA
STP
T/XFMR
TbR
TE
Tl
TT
TVSS
UTP
vs
VT
ws
XMTR
vs
ZS
ZT
zv zz
ANALOG INPUT
AMPERE INTERRUPT RATING
ALARM/ANNUNCIATOR HORN
ANALOG OUTPUT
AUXILIARY
AUXILLARY WATER SUPPLY
CONTROL PANEL
CONTROL RELAY
CONTROL SWITCH
COPPER
CONTROL VALVE
BYPASS (CONTACTOR)
DISCREET INPUT
DEVICENET
DEVICENET TAP
DISCREET OUTPUT
DIGITAL POWER METER
DISCONNECT SWITCH
DEVICENET STARTER ASSEMBLY
DEVICENET TAP
ELAPSED TIME METER
FLOW CONTROLLER
FLOW METER
FUSE
FACILITY WATER SUPPLY
VALVE POSITION (FLOW)
HAND-OFF-AUTO
HUMAN MACHINE INTERFACE
HAND VALVE
INPUT/OUTPUT
CURRENT TO PRESSURE TRANSDUCER
CURRENT CONVERTER
INDUCTION RELAY
LEVEL CONTROLLER
LEVEL ELEMENT
LEVEL SWITCH
LEVEL TRANSMITTER
MASTER CONTROL RELAY
~~~ti~~ ~~~l81Vv11~8/tWfM~~/~T
PLANT AIR
PUSH BUTTON
~~~~o~~rg~M~18~~D
DIFFERENTIAL PRESSURE TRANSMITTER
PRESSURE INDICATOR
PILOT LIGHT
PROGRAMMABLE LOGIC CONTROLLER
PRESSURE REGULATING VALVE
PROXIMITY SWITCH
PRESSURE SWITCH
PRESSURE TRANSMITTER
PRESS TO TEST
POWER
PRESSURE CONVERTER
PRESSURE REGULATOR
~fNR~~ ~121T SWITCH
REDUCED VOLTAGE SOFT STARTER
SOLID NEUTRAL
SUPERVISORY CTRL & DATA ACQUISITION
SAFETY CONTROL RELAY
SOLENOID/SOLENOID VALVE
SELECTOR SWITCH
STATION (OPERATOR CNTRL)
SHIELDED TWISTED PAIR
TRANSFORMER
TIME DELAY RELAY
TEMPERATURE ELEMENT
TEMPERATURE INDICATOR
TEMPERATURE TRANSMITTER
TRANSIENT VOLTAGE SURGE SUPPRESSOR
UNSHIELDED TWISTED PAIR
VIBRATION SWITCH
VIBRATION TRANSMITTER
WEIGHT/TENSION SWITCH
TRANSMITTER
AUX ATS SWITCH
LIMIT SWITCH
POSITION TRANSMITTER
PNEUMATIC PISTON ACTUATOR
POSITIONING LINEAR ACTUATOR (ELEcn
GENERAL NOTES
1. THIS IS A TYPICAL SYMBOLS AND ABBREVIATIONS SHEET,
THEREFOR, SOME SYMBOLS AND ABBREVIATIONS MAY NOT
BE USED WITHIN THIS DRAWING SET.
2. ALL ITEMS SHOWN ARE EXISTING UNLESS INDICATED
OTHERWISE.
t SHEET NAME: E--001
US Army Corps of Engineers<!
PORTl.AND DISTRICT
SHEET
E-001
B
A
DRAWING PLOT SIZE: ANSI D
SPILLWAY
SEE PLAN
I NORTH (WASHINGTON)
I- ADULT FISH LADDER
I I I
/"/ 1'/lil
If
/"° jf. l j 1 · 1 f I
1…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .