W9127827QA004 Market Intelligence SRM at Campbell 24Nov26.pdf

PDF 153 KB Posted

Attached to
Progressive Design-Build - Sustainment, Restoration and Modernization (SRM) Campaign for BLANCHFIELD ARMY COMMUNITY HOSPITAL (BACH) at FORT CAMPBELL, KENTUCKY
Solicitation number
W9127827QA004
Issued by
Not on record

About this file

This is a Special Notice (Request for Information) announcing an upcoming competitive federal construction contract opportunity. The U.S. Army Corps of Engineers (USACE), Mobile District, is soliciting market intelligence responses to gauge industry interest and capability for a Progressive Design-Build (PDB) contract under 10 USC §2808a Other Transaction Authority for Construction. The solicitation number is W9127827QA004, and the project involves Sustainment, Restoration, and Modernization (SRM) of Blanchfield Army Community Hospital (BACH) at Fort Campbell, Kentucky. The NAICS code is 236220 (General Contractor—Nonresidential Building), and the PSC is Y1DA. Interested parties must submit responses by 10 December at 1400 hours (CST) in PDF format to the email addresses provided. Responses must not exceed four pages and should include: (1) offeror name, office address, and points of contact; (2) construction bonding capability per single contract and aggregate level, with current available capacity; and (3) a description of capability to perform the work. Submissions are considered source-sensitive and not subject to public disclosure.

The project scope encompasses comprehensive design, construction phasing, and execution of multi-disciplinary infrastructure upgrades across multiple medical facilities within an active, highly sensitive clinical environment. Work includes renovation of Medical Surgery and Radiology/Urology departments, architectural repairs, mechanical/electrical/plumbing infrastructure renewal, fire alarm and mass notification system replacement, elevator and pneumatic tube system repairs, parking lot and sidewalk repairs, and facility aesthetic and bathroom refreshes across Buildings 650, 5978, 5979, 2434, 5580, 7973, 2524, 2525, 2523, and 98A. The contractor must ensure zero disruption to patient care and clinical operations, comply with Unified Facilities Criteria (UFC) and military medical clinical standards, hold American Society of Healthcare Engineering construction certificates for key personnel, and meet strict security and health screening requirements. The acquisition strategy includes Step 1 (on or around late January 2027) with issuance of an RFQ and down-selection of up to three companies, followed by Step 2 with in-person pitch meetings at Fort Campbell to select the Design-Build team. The final agreement will be Firm-Fixed-Price (FFP) for successive design and construction milestones, with Post-award Phase 1 covering design and preconstruction services and Post-award Phase 2 covering final design and construction.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECIAL NOTICE

Solicitation No. W9127827QA004

Title: Progressive Design-Build - Sustainment, Restoration and Modernization (SRM) Campaign for BLANCHFIELD ARMY COMMUNITY HOSPITAL (BACH) at FORT CAMPBELL, KENTUCKY.

The U.S. Army Corps of Engineers (USACE) is issuing this special notice to announce an upcoming competition for a design and construction solicitation for the SRM Campaign for BACH, using Progressive Design-Build under 10 USC §2808a Other Transaction Authority for Construction.

This notice is for informational and planning purposes to allow interested parties to prepare for and provide feedback prior to the official solicitation release.

MARKET INTELLIGENCE

USACE is conducting market intelligence to provide an overview of the project, plan of action, and anticipated requirements. The purpose of this market intelligence is to gain knowledge of potential qualified entities. Responses are requested with the following information, which shall not exceed a total of 4 pages.

1. Offerors' name, home office and/or local office assigned to perform work address, points of contact with telephone numbers and e-mail addresses.

2. Bonding capability (Construction bonding level per single contract and aggregate construction bonding level, both expressed in dollars, along with current available bonding capacity).

3. Description of capability to perform the proposed agreement.

PROJECT OVERVIEW

• Project Title: Progressive Design-Build - Sustainment, Restoration and Modernization (SRM) Campaign for BACH

• Location: Fort Campbell, Kentucky

• Agency: U.S. Army Corps of Engineers – Mobile District

• NAICS Code: 236220

• PSC: Y1DA

PROJECT DESCRIPTION

This Continental United States (CONUS) requirement is for a stand-alone contract executed under Progressive Design-Build (PDB) Other Transaction Authority (OTA) for Construction to support the Sustainment, Restoration, and Modernization (SRM) Campaign for BACH at Fort Campbell, KY. The scope of work comprises comprehensive design, construction phasing, and execution of multi-disciplinary infrastructure upgrades and facility renovations across multiple active medical treatment facilities.

Because all work will be performed within a fully operational, highly sensitive clinical environment, the selected contractor will be required to meticulously phase construction to ensure zero disruption to patient care, daily medical operations, and critical life-safety systems. The contractor shall deliver fully integrated, functional, and compliant facilities that strictly adhere to all applicable Unified Facilities Criteria (UFC), military medical clinical standards, and the formal Statement of Work (SOW).

The facility and infrastructure modernization effort is organized into distinct, phased sub-projects targeting critical utility systems and clinical spaces. Building 650’s utility and life-safety modernization begins with (1) Medical Surgery Department Renovation, (2) Radiology & Urology Department Renovation, (3) Architectural Repair and Corridor Refresh, (4) Mechanical Infrastructure Repair & Renewal, (5) Electrical Infrastructure Repair & Renewal, (6) Plumbing Infrastructure Repair & Renewal,

(7) Fire Alarm & Mass Notification System Replacement, (8) Elevator Repair & Renewal, (9) Pneumatic Tube System Infrastructure Repair & Renewal. The effort also includes (10) Parking Lots and Sidewalks Infrastructure Repair & Renewal for Buildings 650, 5978, 5979, 2434, 5580 and 7973, (11) Infrastructure Repair & Renewal of Lapointe Central Plant and Health Clinic at Buildings 5978 and 5979, (12) Warehouse Infrastructure Repairs of Building 2434, (13) Infrastructure Repair & Renewal of Taylor Dental Clinic at Building 5580, (14) Whole Building Infrastructure Repair & Renewal of Byrd Adkins Clinic at Building 7973, (15) Repair and Renewal of Intrepid Sleep Center at Building 2524, (16) Building Infrastructure Repair & Renewal for the Public Affairs at Building 2525, (17) Building Infrastructure Repair & Renewal for Family Advocacy at Building 2523, and (18) Facility Interior Infrastructure Repair & Renewal for the Pharmacy at Building 98A.

Mechanical, plumbing, and building envelope integrity form a core pillar of the SRM Campaign. For the main hospital at Building 650, the contractor will execute LOA-3 renovation of Medical Surgery;

replace/repair renewal building systems of Radiology/Urology areas; replace end-of-life architectural systems including corridor flooring, wall coverings and ceilings, replace VAV boxes and air devices, replace panels, transformers and switches in electrical rooms, replace corridor lighting; replace AHUs and controls and perform heating system and steam plant repairs; replace end-of life ATSs and generator controls, 14 distribution switchboards and the public address and clock system; replace end-of-life cold and hot water heaters/tanks, renew hot water piping and replace gas alarm panels, manifolds WAGD vacuum and dental vacuum; replace fire alarm and mass notification system; repair/renew end-of-life elevators; repair/renew end-of-life pneumatic tube systems; and repair/replace end-of-life parking lots.

Buildings 5978 and 5979 - Lapointe Health Clinic and the Boiler Plant require repair/renewal of portions of the roof, AHUs, VAVs water heaters, medical gas, sump pumps and the fire alarm system. Building 2434 - the MDS Warehouse will undergo replacement of the fire alarm system and repair/renewal of AHUs and miscellaneous building systems. Repair/renewal of miscellaneous mechanical systems (WH, WS, DX CUs and Hum) are planned for Building 5580 - Taylor Dental, while Building 7973 - Byrd Medical and Adkins Dental require repair/renewal of HVAC (DX and Hum). The fire alarm system will be replaced and AHUs and other miscellaneous systems will be repaired/renewed at Intrepid - Building 2524, whereas Building 2523 – Family Advocacy and Building 2525 - Public Affairs require replacement of the fire alarm system and repair/renewal of various mechanical and electrical systems. Building 2525 – Pharmacy requires repair/renewal of miscellaneous architectural, mechanical and plumbing systems.

Overall facility aesthetics, public navigation, and staff support areas will be refreshed to improve the patient experience. This common area refresh spans 31,040 square feet across floors one through four of B2825, replacing interior finishes on floors, walls, and ceilings, modernizing clinical lighting, and fully updating clinical entrances and reception desks. This aesthetic refresh is tightly integrated with overhead mechanical repairs to replace old hot water piping and ductwork above the common area ceilings as needed. Additionally, a 3,247-square-foot bathroom refresh will replace fixtures and finishes throughout clinical and common areas, specifically including the pathology toilets. Finally, the hospital's dining facility (DFAC) in B2825 will undergo a 3,676-square-foot modernization targeting the serving and dining areas to support staff and visitor wellness.

To operate safely within these facilities, the contractor’s personnel will be required to meet strict security and health screening requirements prior to performing work. Depending on the specific facility or area of work, contractor employees may be required to undergo specialized medical testing and receive targeted immunizations that go beyond basic OSHA requirements before they are authorized to enter controlled spaces. Because of these unique operational hazards, the performing contractor must be prepared to manage elevated operational risks by securing increased liability insurance, providing specialized worker training, and equipping personnel with advanced Personal Protective Equipment (PPE) to protect patient health, clinical safety, and the well-being of their own staff.

The contractor must possess a thorough understanding of and demonstrated experience complying with the current codes and standards established by the applicable Authorities Having Jurisdiction (AHJ), the American Association for Accreditation of Laboratory Animal Care (AAALAC), and The Joint Commission (TJC). This includes strict adherence to the medical codes and standards governing healthcare facilities and laboratories published by the National Fire Protection Association (NFPA), with all code-required testing and certifications remaining the sole responsibility of the contractor. Key personnel, to include on-site supervisors, are required to hold an American Society of Healthcare Engineering construction certificate. Additionally, while the Government is responsible for identifying the physical facility or location of the work, the contractor is entirely responsible for verifying all existing site conditions, quantities, measurements, and distances, as any dimensions provided in the Statement of Work are strictly for estimation purposes.

NEXT STEPS:

After receipt and review of the Special Notice Responses, USACE will use a streamlined competitive selection process similar to other PDB w /OTA acquisitions.

• Step 1 –On or around late January 2027 – the Government may issue an RFQ for the requirement. Interested parties will submit a Statement of Qualifications (max # of pages to be defined in RFQ). The government intends to down-select up to 3 Companies to proceed to Step 2.

• Step 2 – Pitches: Selected Companies will participate in pitch meetings in person, most likely at Fort Campbell, KY. One company will be selected as the Design-Build team for award of the initial design and preconstruction services with a modification for design completion and construction.

ACQUSITION STRATEGY – AWARD

The agreement will be awarded to the most qualified progressive design-build entity (PDBE) to provide design development, preconstruction services, and construction. Post-award Phase 1 of PDB includes Design and Pre-construction services and Post-award Phase 2 includes the final design and construction.

The agreement will be Firm-Fixed-Price (FFP). The FFP for successive design and construction milestones will be agreed to as the design progresses and funds are available.

All interested parties should monitor the official solicitation announcement, which will provide complete details and submission instructions. Draft documents may be provided at a future date for feedback and informational purposes only and are subject to change upon issuance of the formal Program Solicitation.

Primary Point of Contact:

Drenna.L.Thompson@usace.army.mil Courtesy Copy:

Robert.S.McAllister@usace.army.mil

NO HARDCOPY RESPONSES WILL BE ACCEPTED. ALL RESPONSES WILL BE ELECTRONIC

and submitted in pdf format to the following email addresses: drenna.l.thompson@usace.army.mil and Cc robert.s.mcallister@usace.army.mil. The subject line of the email shall reference the solicitation number in the announcement and submittals are due no later than 10 December at 1400 hours (CST).

Electronic submittals will be retained for future reference; however, they are to be considered source sensitive and not subject to public disclosure.

This is not a Request for Proposal (RFQ), only a Request for Information (RFI). No agreement or contract will result from this Special Notice. This notice does not constitute any commitment by the Government.

Submissions will be evaluated strictly to gauge industry interest and to determine the technical capability of prospective entities to perform the specialized construction work described herein.

SPECIAL NOTICE
Solicitation No. W9127827QA004

File details come from the government source that posted it. Updated .