B3_Amendment_1_19R0074.pdf

PDF 9 MB Posted

Attached to
Construction of South Access Control Point for Fort Bliss Replacement Hospital
Solicitation number
W9126G19R0074
Issued by

About this file

Amendment 0001

View the file

Other files

File Type Posted
B3_Amendment_2_19R0074.pdf PDF
B5_Site_Visit_Roster_19R0074.pdf PDF
RFP_g19r0074.pdf PDF
ACP-SouthDrawings_3.zip ZIP file
ACP-SouthDrawings_2.zip ZIP file
ACP-SouthDrawings_1.zip ZIP file
FBHR_ACP-North_and_South_APPENDICES_1_20-MARC-2019.pdf PDF
FBHR_ACP-North_and_South_APPENDICES_2_20-MAR-2019.pdf PDF
B3_W9126G19R0074.pdf PDF
11-1595_ECP_WBAMC_Replace.pdf PDF
South_ACP.pdf PDF
FBHR_ACP-North_and_South_NARRATIVE_20-MAR-2019.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

The Solicitation for Access Control Point - South, Fort Bliss Hospital Replacement Hospital, Fort Bliss, TX, is amended as follows:

See SF30 Continuation Sheet(s)

NOTE: Proposal Receipt date is 26 April 2019, 2:00 p.m., CST, as previously announced.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 2

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY

16B. UNITED STATES OF AMERICA 15C. DATE SIGNED 15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer) (Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X 9A. AMENDMENT OF SOLICITATION NO.

W9126G19R0074

X 9B. DATED (SEE ITEM 11)

26-Mar-2019

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

9-Apr-2019

CODE

US ARMY ENGINEER DISTRICT, FORT WORTH

ATTN: CESWF-CT

819 TAYLOR ST, ROOM 2A19

P.O. BOX 17300

FORT WORTH TX 76102-0300

W9126G 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODE CODE

EMAIL: TEL:

W9126G19R0074

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

CHANGES TO SOLICITATION W9126G19R0074

CHANGES TO THE DRAWINGS

1. Replacement Drawings.- Replace the drawings listed below with the attached new drawings(s) of the same number, bearing the notation “W9126G19R0074 Amendment 0001”:

X-600-AC - ACP - SIGN QUANTITY ESTIMATES

X-601-AC - INTERIOR MESSAGE SCHEDULE

XE-101 - TYPOGRAPHY AND SYMBOLS

XE-102 - COLORS AND MATERIALS

XE-110-H - EXTERIOR LOCATION PLAN (1 of 3) XE-111-I - EXTERIOR LOCATION PLAN (2 of 3) XE-112-J - EXTERIOR LOCATION PLAN (3 of 3)

XE-113S - EXTERIOR MESSAGE SCHEDULE

XE-114 - (MED) MAIN ENTRANCE DIRECTIONAL

XE-115 - (MID) MAIN ID

XE-116 - (MID) MAIN ID (CONT)

XE-117 - (PDR) PRIMARY DIRECTIONAL

XE-118 - (PDR) PRIMARY DIRECTIONAL (CONT)

XE-119 - (SDR) SECONDARY DIRECTIONAL

XE-120 - (TDR) TERTIARY DIRECTIONAL

XE-121 - (BSID) BUS STOP-(SSID) SHUTTLE (IPL) INFO-PANEL

XE-126 - (DLLC-DLLA) DIMENSIONAL LETTERS CLINIC ENTRANCE - R1

XE-131 - (TREG) TRAFFIC REGULATORY

XE-132 - (TREG) TRAFFIC REGULATORY (CONT)

XI-103-AC RID, RIDB, RNM, RNMB

XI-104-AC RRA, RRAB, RRBV

XI-107-AC OID, OIDB

XI-108-AC SID, SIDE, RIDE

XI-111-AC EXIT, ARA, SEG, ARAD

XR-101-GH-S - SOUTH GATEHOUSE - ROOM-REGULATORY

XR-101-SO-S - SOUTH SEARCH OFFICES - ROOM-REGULATORY

XR-101-VC-S - VISITOR CONTROL CENTER - ROOM-REGULATORY

Note: The attached amended drawings have not changed from the set submitted with the original Solicitation; only color has been added to aid in clarification.

End of Summary of Changes

54321

D

C

B

A

US Army Corps of Engineers FT. Worth District

D

AT

E:

SO

LI

C

IT

AT

IO

N N

U M

BE

R

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

SHEET

IDENTIFICATION

FI

LE

N

AM

E:

C H

EC

KE

D B

Y:

C O

N

TR

AC

T

N U

M

BE

R

FI

LE

N U

M

BE

R

PL

O

T D

AT

E:

SI

ZE

PL

O T

SC

AL

E:

AR

CH

IT

EC

TU

RE

E

NG

IN

EE

RI

NG

CO

NS

UL

TI

NG

AL

EX

AN

DR

IA

, V

A

AR

C H

E

54321

Fo rt

Bl is s Ho sp ita l R ep la ce m en t Ac ce ss

C on tro l P oi nt s U

S

AR

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

FO

R

T W

O R

TH

D

IS

TR

IC

T

W

2 D Y-

-D

- 0

/0

6 /

X-600-AC

AC

P

- S

IG

N

AG

E

- S

IG

N

Q U

AN

TI

TY

ES

TI

M

AT

ES

Au th or C he ck er

D es ig ne r

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

SHEET 110 OF 318

SETAMITSE YTITNAUQ NOITCNUF/EMAN NGIS EPYT NGIS TEEHS GNIWARD

1 .D.I MOOR DIR301-IX

8 )ESUOH FO KCAB( .D.I MOOR BDIR301-IX

0 REBMUN .D.I MOOR MNR301-IX

0 )ESUOH FO KCAB( REBMUN .D.I MOOR BMNR301-IX

2 .D.I MOORTSER ARR401-IX

4 )ESUOH FO KCAB( .D.I MOORTSER BARR401-IX

0 )NOITAIRAV ESUOH FO KCAB( .D.I MOORTSER VBRR401-IX

0 EGRAL .D.I MOOR ROJAM LIRM501-IX

0 LLAMS .D.I MOOR ROJAM SIRM501-IX

0 .D.I MOOR ECNEREFNOC DIRC501-IX

0 DRAZIW HTIW .D.I MOOR TNEITAP WIRP601-IX

1 .D.I ECIFFO DIO701-IX

0 )ESUOH FO KCAB( .D.I ECIFFO BDIO701-IX

0 .D.I RIATS DIS801-IX

0 ROIRETXE .D.I RIATS EDIS801-IX

91 ROIRETXE .D.I MOOR EDIR801-IX

0 .D.I NOITATSKROW DISW901-IX

0 TCA YTILIBATNUOCCA DNA YTILIBATROP ECNARUSNI HTLAEH - AAPIH APIH011-IX

0 GAT SEITILICAF CAF011-IX

1 .D.I TIXE ADA TIXE111-IX

0 SSERGE RIATS/.D.I ROOLF GES111-IX

0 ECNATSISSA EGUFER FO AERA ARA111-IX

0 LANOITCERID ECNATSISSA EGUFER FO AERA DARA111-IX

0 TENIBAC REHSIUGNITXE ERIF CEF211-IX

0 REDLOH NALP NOITAUCAVE CAVE211-IX

0 ERIF FO ESAC NI ERIF211-IX

0 EGRAL EUQALP NOITAMROFNI LPI311-IX

0 MUIDEM EUQALP NOITAMROFNI MPI311-IX

0 LLAMS EUQALP NOITAMROFNI SPI311-IX

0 LOBMYS YROTALUGER GER411-IX

0 SNOITATS HSAW EYE SWE411-IX

0 TNUOM-T SNOITATS HSAW EYE TSWE411-IX

0 YROTCERID SUPMAC RDC511-IX

0 LX YROTCERID ROTAVELE XRDE611-IX

0 EGRAL YROTCERID ROTAVELE LRDE611-IX

0 )ESUOH FO KCAB( YROTCERID ROTAVELE BRDE611-IX

0 MUIDEM YROTCERID ROTAVELE MRDE711-IX

0 LLAMS YROTCERID ROTAVELE SRDE711-IX

0 YROTCERID BAC ROTAVELE CRDE811-IX

0 EGRAL DETNUOM LLAW LANOITCERID LWD911-IX

0 MUIDEM DETNUOM LLAW LANOITCERID MWD911-IX

0 LLAMS DETNUOM LLAW LANOITCERID SWD911-IX

0 )ESUOH FO KCAB( EGRAL DETNUOM LLAW LANOITCERID BLWD021-IX

0 )ESUOH FO KCAB( MUIDEM DETNUOM LLAW LANOITCERID BMWD021-IX

0 )ESUOH FO KCAB( LLAMS DETNUOM LLAW LANOITCERID BSWD021-IX

0 EGRAL DAEHREVO LANOITCERID LOD121-IX

0 MUIDEM DAEHREVO LANOITCERID MOD121-IX

0 LLAMS DAEHREVO LANOITCERID SOD221-IX

0 IRT DAEHREVO LANOITCERID IRTD321-IX

0 EGRAL .D.I GNITCEJORP LMTP421-IX

0 MUIDEM .D.I GNITCEJORP MMTP421-IX

0 GNILIEC .D.I REBMUN DEB DIB521-IX

0 SCIHPARG LYNIV RGV621-IX

0 SSALG NO SCIHPARG LYNIV GRGV721-IX

0 DEEL EUQALP LANOITAMROFNI DLPI231-IX

0 DRAWA GNITAR DEEL - EUQALP ARLP231-IX

0 ECNARTNE GNIDLIUB NOITARTSINIMDA 10GS331-IX

0 YALPSID LLAH YLBMESSA 20GS431-IX

0 ROOLF TSRIF LATROP YRTNE CINILC 30GS531-IX

0 SROOLF REPPU LATROP YRTNE CINILC 40GS631-IX

0 SCIHPARG NOITPECER CINILC 50GS731-IX

0 LATROP YRTNE SROTAVELE CINILC 90GS831-IX

0 KSOIK CINORTCELE 60GS931-IX

0 YBBOL ROTAVELE LATIPSOH 70GS041-IX

0 ROOLF TSRIF ECNARTNE LATIPSOH 80GS141-IX

0 EGANGIS YREVRES 01GS241-IX

0 YALPSID ECIVRES 11GS441-IX

C O

N F

O R

M A

N C

E S

E T

2-

-2

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

C O N F O R M A N C E

S E T

C O N F O R M A N C E

S

W9126G19R0074 AMENDMENT 0001

C

B

A

US Army Corps of Engineers FT. Worth District

D

AT

E:

SO

LI

C

IT

AT

IO

N N

U M

BE

R

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SU

BM

IT

TE

D B

Y:

SHEET

IDENTIFICATION

FI

LE

N

AM

E:

C H

EC

KE

D B

Y:

C O

N

TR

AC

T

N U

M

BE

R

FI

LE

N U

M

BE

R

PL

O

T D

AT

E:

SI

ZE

PL

O T

SC

AL

E:

AR

CH

IT

EC

TU

RE

E

NG

IN

EE

RI

NG

CO

NS

UL

TI

NG

AL

EX

AN

DR

IA

, V

A

AR

C H

E

54321

Fo rt

Bl is s Ho sp ita l R ep la ce m en t Ac ce ss

C on tro l P oi nt s U

S

AR

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

FO

R

T W

O R

TH

D

IS

TR

IC

T

W

2 D Y-

-D

- 0

/0

6 /

X-601-AC

AC

P

- S

IG

N

AG

E

- I

N

TE

R

IO

R M

ES

SA

G E

SC

H

ED

U

LE

R

SS

D N

Z

R

SS

100% SUBMITTAL

PRELIMINARY - NOT FOR CONSTRUCTION

MESSAGE TEXT FOR ALL SIGN TYPES SHALL BE

COORDINATED WITH THE CONTRACTING OFFICER

PRIOR TO FABRICATION. REFER TO DRAWINGS AND

LOCATION PLANS FOR COMPLETE INFORMATION.

TEXT WITHIN PARENTHESES IN MESSAGE COLUMN

IS NOT PART OF SIGN MESSAGE.

SIGNAGE ROOM AND REGULATORY SCHEDULE - ACP (FIRST FLOOR)

LEVEL LOCATION TYPE MESSAGE SIDE A

SIGN

COLOR COMMENTS MOUNTING

LEVEL 1 V107 RIDB Communications V107

(BRAILLE)

talF - llaW-

LEVEL 1 V108 OID Visitor Center Office V108

(BRAILLE)

talF - llaW-

LEVEL 1 V109 EXIT EXIT

(BRAILLE)

talF - llaW-

LEVEL 1 V111A RID Provost V111

(BRAILLE)

talF - llaW-

LEVEL 1 V111B RIDE Provost V111

(BRAILLE)

talF - llaW-

SIGNAGE ROOM AND REGULATORY SCHEDULE - ACP (FIRST FLOOR)

LEVEL LOCATION TYPE MESSAGE SIDE A

SIGN

COLOR COMMENTS MOUNTING

LEVEL 1 NG100A RIDE South Gate Guard Room

NG100

(BRAILLE)

talF - llaW-

LEVEL 1 NG100B RIDE South Gate Guard Room

NG100

(BRAILLE)

talF - llaW-

LEVEL 1 NG101 RRAB (PICTO M/W/HC)

RESTROOM

(BRAILLE)

talF - llaW-

LEVEL 1 NG102 RIDB Storage

NG102

(BRAILLE)

talF - llaW-

LEVEL 1 NG103 RIDE Outside Storage

NG103

(BRAILLE)

talF - llaW-

LEVEL 1 NG104 RIDE Mechanical/ Electrical

NG104

(BRAILLE)

talF - llaW-

LEVEL 1 NG105 RIDB Communications

NG105

(BRAILLE)

talF - llaW-

LEVEL 1 NS100 RIDE North Search Office

NS100

(BRAILLE)

talF - llaW-

LEVEL 1 NS101 RIDB Break Room

NS101

(BRAILLE)

talF - llaW-

LEVEL 1 NS102 RRAB (PICTO M/W/HC)

RESTROOM

(BRAILLE)

talF - llaW-

LEVEL 1 NS103 RIDB Storage

NS103

(BRAILLE)

talF - llaW-

LEVEL 1 NS104 RIDE Outside Storage

NS104

(BRAILLE)

talF - llaW-

LEVEL 1 NS105 RIDE Mechanical

NS105

(BRAILLE)

talF - llaW-

LEVEL 1 NS106 RIDE Electrical

NS106

(BRAILLE)

talF - llaW-

LEVEL 1 SG100A RIDE South Gate Guard Room

SG100

(BRAILLE)

talF - llaW-

LEVEL 1 SG100B RIDE South Gate Guard Room

SG100

(BRAILLE)

talF - llaW-

LEVEL 1 SG101 RRAB (PICTO M/W/HC)

RESTROOM

(BRAILLE)

talF - llaW-

LEVEL 1 SG102 RIDB Storage

SG102

(BRAILLE)

talF - llaW-

LEVEL 1 SG103 RIDE Outside Storage

SG103

(BRAILLE)

talF - llaW-

LEVEL 1 SG104 RIDE Mechanical/ Electrical

SG104

(BRAILLE)

talF - llaW-

LEVEL 1 SG105 RIDB Communications

SG105

(BRAILLE)

talF - llaW-

LEVEL 1 SS100 RIDE South Search Office

SS100

(BRAILLE)

talF - llaW-

LEVEL 1 SS101 RIDB Break Room

SS101

(BRAILLE)

talF - llaW-

LEVEL 1 SS102 RRAB (PICTO M/W/HC)

RESTROOM

(BRAILLE)

talF - llaW-

LEVEL 1 SS103 RIDB Storage

SS103

(BRAILLE)

talF - llaW-

LEVEL 1 SS104 RIDE Outside Storage

SS104

(BRAILLE)

talF - llaW-

LEVEL 1 SS105 RIDE Mechanical

SS105

(BRAILLE)

talF - llaW-

LEVEL 1 SS106 RIDE Electrical

SS106

(BRAILLE)

talF - llaW-

LEVEL 1 V101 RIDE Waiting V101

(BRAILLE)

talF - llaW-

LEVEL 1 V102 RRA (PICTO W/HC)

WOMEN

(BRAILLE)

talF - llaW-

LEVEL 1 V103 RRA (PICTO M/HC)

MEN

(BRAILLE)

talF - llaW-

LEVEL 1 V104 RIDE Mechanical/ Electrical V104

(BRAILLE)

talF - llaW-

LEVEL 1 V106 RIDB Janitor V106

(BRAILLE)

talF - llaW-

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

SHEET 111 OF 318

C O

N F

O R

M A

N C

E S

E T

2-

-2

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

C O N F O R M A N C E

S

N F O R M A N C E

S

SHEET 117 OF 318

O N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

ABCDEFGHIJKLMNOP

QRSTUVWXYZ

1234567890$&().,;:”* abcdefghijklmnopqrstuvwxyz 1234567890$&().,;:”*

(EXCEPT WHERE NOTED OTHERWISE)

ABCDEFGHIJKLMNOP

QRSTUVWXYZ

1234567890$&().,;:”* abcdefghijklmnopqrstuvwxyz 1234567890$&().,;:”*

(EXCEPT WHERE NOTED OTHERWISE)

NOTE:

TYPE SPECIFICATION:

CLEARVIEW HIGHWAY 2-W

ALL KERNING: OPTICAL

DIRECTIONAL TEXT

TRACKING: VARIES

NOTE:

TYPE SPECIFICATION:

CLEARVIEW HIGHWAY 3-W

ALL KERNING: OPTICAL

DIRECTIONAL TEXT

TRACKING: VARIES

TYPOGRAPHY

ABCDEFGHIJKLMNOP

QRSTUVWXYZ

1234567890$&().,;:”* abcdefghijklmnopqrstuvwxyz 1234567890$&().,;:”*

NOTE:

TYPE SPECIFICATION:

CLEARVIEW HIGHWAY 6-B

ALL KERNING: OPTICAL

DIRECTIONAL TEXT

TRACKING: VARIES

(EXCEPT WHERE NOTED OTHERWISE)

ABCDEFGHIJKLMNOPQRSTUVWXYZ

1234567890$&().,;:”* abcdefghijklmnopqrstuvwxyz 1234567890$&().,;:”*

NOTE:

TYPE SPECIFICATION:

DINOT REGULAR (DIN - OT)

ALL KERNING: OPTICAL

DIRECTIONAL TEXT

TRACKING: VARIES

(EXCEPT WHERE NOTED OTHERWISE)

ABCDEFGHIJKLMNOPQRSTUVWXYZ

1234567890$&().,;:”* abcdefghijklmnopqrstuvwxyz 1234567890$&().,;:”*

NOTE:

TYPE SPECIFICATION:

DINOT MEDIUM (DIN - OT)

ALL KERNING: OPTICAL

DIRECTIONAL TEXT

TRACKING: VARIES

(EXCEPT WHERE NOTED OTHERWISE)

ABCDEFGHIJKLMNOP

QRSTUVWXYZ

1234567890$&().,;:”* abcdefghijklmnopqrstuvwxyz 1234567890$&().,;:”*

NOTE:

TYPE SPECIFICATION:

CLEARVIEW HIGHWAY 5-W

ALL KERNING: OPTICAL

DIRECTIONAL TEXT

TRACKING: VARIES

(EXCEPT WHERE NOTED OTHERWISE)

C3 SYMBOLS

D3 DIRECTIONAL ARROWS

A1 TYPEFACE-CLEARVIEW HIGHWAY 6-B

A3 TYPEFACE-DINOT MEDIUM (DIN-OT)

ABCDEFGHIJKLMNOPQRSTUVWXYZ

1234567890$&().,; :”* abcdefghijklmnopqrstuvwxyz 1234567890$&().,; :”*

NOTE:

TYPE SPECIFICATION:

TRADE GOTHIC BOLD CONDENSED,

ALL KERNING: OPTICAL

DIRECTIONAL TEXT

TRACKING OF 25 EXCEPT WHERE NOTED

A3 TYPEFACE-TRADE GOTHIC BOLD CONDENSED

B3 TYPEFACE-DINOT REGULAR (DIN-OT)

B1 TYPEFACE-CLEARVIEW HIGHWAY 5-W

C1 TYPEFACE-CLEARVIEW HIGHWAY 3-W

D1 TYPEFACE-CLEARVIEW HIGHWAY 2-W

GREEN LEED PARKING BICYCLE PARKING

NO FIREARMS NO SMOKING SMOKING PERMITTED NO PHOTOGRAPHY TRAILPARKING

BUS STOP ACCESSIBLE HIGHWAY HIGHWAY

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

LOOP

SPUR

N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

PSE-3

PAINT

COLOR: SIGNAL JET BLACK

FINISH: NON-GLARE (MATTE)

& GLOSS

PSE-4

PAINT

PANTONE® 1545 U

COLOR: DARK BROWN

FINISH: SATIN

PSE-2

PAINT

COLOR: SATIN HI-HIDE WHITE

FINISH: NON-GLARE (MATTE)

VE-1

VINYL

REFLECTIVE FILM

COLOR: WHITE

FINISH: REFLECTIVE

VE-4

VINYL

TRANSLUCENT VINYL

COLOR: CARDINAL RED

VE-9

VINYL

OPAQUE VINYL

COLOR: CARDINAL RED

FINISH: NON-GLARE (MATTE)

ME-1

BRUSHED ALUMINUM,

HORIZONTAL GRAIN FINISH,

ARCHITECTURAL GRADE A-43

FINISH: CLEAR ANODIZED WITH

CLEAR PROTECTIVE COATING

ME-7

ACRYLIC

COLOR: TRANSLUCENT

(FOR LIT SIGNS)

ME-8

PHENOLIC RESIN PANEL,

UV PROTECTED, EXTERIOR

GRADE, SINGLE SIDED

MATERIAL: PHENOLIC RESIN

WITH DIGITALLY

PRINTED GRAPHICS

PSE-1

PAINT:

COLOR: BROCCOLI CREAM

FINISH: NON-GLARE (MATTE)

PSE-8

UV MAP PROTECTANT CLEARCOAT

FINISH: NON-GLARE (MATTE)

NOTE: APPLY TO ALL EXTERIOR

PAINT SURFACES

WHERE APPLICABLE FOR

WEATHER AND UV PROTECTION

PSE-6

PAINT

COLOR: BAYOU BLUE

FINISH: NON-GLARE (MATTE)

PSE-7

PAINT

RED VINYL

COLOR: CARDINAL RED, VE-9

FINISH: NON-GLARE (MATTE)

VE-2

VINYL

COLOR: WHITE

FINISH: NON-GLARE (MATTE)

VE-3

VINYL

COLOR: BLACK

FINISH: NON-GLARE (MATTE)

VINYL

ME-13

CAST ALUMINUM 1" THICK WITH

INFILLED PAINTED AREAS

EXACT LOGO AND COLORS TO BE

PROVIDED BY CLIENT

ME-14

ALUMINUM .090 (1/8”) thick

ME-15

EXTERIOR GRADE PHOTOPOLYMER

METAL/COATINGS ON METAL

ME-9

TINTED TRANSLUCENT POLYCARBONATE

WITH VINYL 800 PREMIUM CAST

TRANSLUCENT FILM ON SECOND SURFACE

“TIDEWATER”

ME-10

BUILDING STONE VENEER

TUPELO HONEY

OTHER

PAINT COLORS (NON GLARE UNLESS STATED OTHERWISE,

FINISH: LOW VOC POLYURETHANE WITH APPROPRIATE UNDERCOATING)

VE-5

VINYL

TRANSLUCENT VINYL

COLOR: WHITE

VE-6

VINYL

TRANSLUCENT VINYL

COLOR: INTENSE BLUE

VE-10

OPAQUE VINYL

COLOR: MATTE INTENSE BLUE

FINISH: NON-GLARE (MATTE)

VE-8

VINYL

DAY/NIGHT FILM

COLOR: DARK GRAY

VE-11

VINYL

REFLECTIVE VINYL

COLOR: BLACK

VE-7

VINYL

COLOR: BROWN

MATCH PANTONE® 1545 U

FINISH: NON-GLARE (MATTE)

PARKING LOT COLORS

ME-2

SINGLE SIDED,

DIAMOND GRADE REFLECTIVE

COATING ON ALUMINUM

WHITE (RETROREFLECTIVE)

ME-3

SINGLE SIDED,

DIAMOND GRADE REFLECTIVE

COATING ON ALUMINUM

GREEN (RETROFLECTIVE)

ME-4

SINGLE SIDED,

DIAMOND GRADE REFLECTIVE

COATING ON ALUMINUM

BLUE (RETROREFLECTIVE)

ME-5

TPP

THERMOSET POLYESTER POWDERCOAT

COLOR: GUN METAL

(ON DOT SIGNAGE)

ME-16

PAINT:

FINISH: DURANAR SUNSTORM

COLOR: GALAXY SILVER

ME-6

SINGLE SIDED,

DIAMOND GRADE REFLECTIVE

COATING ON ALUMINUM

RED (RETROREFLECTIVE)

A1 PROJECT COLORS AND MATERIALS

PSE-9

PAINT

MATCH PANTONE® 1545 U 50% TINT

COLOR: DESERT BROWN

FINISH: SATIN

PSE-16

LOT G: RED

PAINT:

ACRYLIC POLYURETHANE

COLOR: TEXAS SCARLET

FINISH: SATIN

PSE-12

LOT C: GREEN

PAINT:

ACRYLIC POLYURETHANE

COLOR: GREEN RIBBON

FINISH: SATIN

PSE-11

LOT B: ORANGE

PAINT:

ACRYLIC POLYURETHANE

COLOR: MATCHBOX CAR ORANGE

FINISH: SATIN

PSE-17

LOT H: YELLOW

PAINT:

ACRYLIC POLYURETHANE

COLOR: HIGHWAY YELLOW

FINISH: SATIN

PSE-10

LOT A: BLUE

PAINT:

ACRYLIC POLYURETHANE

COLOR: SODA CAN BLUE

FINISH: SATIN

PSE-13

LOT D: PURPLE

PAINT:

ACRYLIC POLYURETHANE

COLOR: PURPLE PRINT

FINISH: SATIN

PSE-15

LOT F: BROWN

PAINT:

ACRYLIC POLYURETHANE

COLOR: COLONIAL RED

FINISH: SATIN

PSE-14

LOT E: DARK BLUE

PAINT:

ACRYLIC POLYURETHANE

COLOR: CUERNAVACA BLUE

FINISH: SATIN

ME-11

CAST STONE

TBD

ME-12

FAUX STONE

MATERIAL: TBD

COLOR: TBD

PSE-5

PAINT

COLOR: BRITISH RAILWAYS GREEN

FINISH: NON-GLARE (MATTE)

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

SHEET 118 OF 318

N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

F H I

E

GH

F

G H H I

KEY PLAN NO SCALE

G H E F

I J

A B C D

018 PDR

scale 1”= 50’-0”

200’- 0”

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

NOTES:

REFER TO C-005 FOR FUEL EFFICIENT/ CAR POOL LOCATIONS AND NUMBERS.

NOTE: FIELD VERIFY ALL LOCATIONS AND COORDINATE WITH ALL UTILITIES.

NOTE: ALL SETBACKS 12’-0” FROM CURB UNLESS OTHERWISE NOTED.

TRAIL MARKERS ADDED EVERY 1/8 MILE ON TRAIL.

BSID: Sun Metro bus stop location SSID: Shuttle bus stop location

F1F1

F2F2F2

F3F3F3

F4

F5F5F5

F6F6F6

F7F77

F8

F9F99F

G4

G5G5G5

G6G6G6

G7G7G7

G8

G9G9G9

G11G

G3G3G3

G2G2G2

SHEET 119 OF 318

N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

SHEET 120 OF 318

I J

IIH

IH

F J

KEY PLAN NO SCALE

G H E F

I J

A B C D

PRIMARY ACP

ID CHECK

PROPERTY SUBSTATION

GATEGA

VISITORV O

PARKINGP R G

ACCESS ROAD “B

412 BSID

432 IPL

A

A scale 1”= 50’-0”

A 400’-0”12

’-0

FIELD VERIFY

LOCATION

AND ALL

DIMENSIONS

’-0

’-0

” A

PP

RO

X.

CU

RB

T O

CU

RB

25’-0”

APPROX.

ADJUST AS NEEDED

010 DLLC

014 MED

012 SDR

008 TDR

003 PDR

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

NOTES:

REFER TO C-005 FOR FUEL EFFICIENT/ CAR POOL LOCATIONS AND NUMBERS.

NOTE: FIELD VERIFY ALL LOCATIONS AND COORDINATE WITH ALL UTILITIES.

NOTE: ALL SETBACKS 12’-0” FROM CURB UNLESS OTHERWISE NOTED.

TRAIL MARKERS ADDED EVERY 1/8 MILE ON TRAIL.

836 TREG

834 TREG 838 TREG

NO SMOKING...

50’ OF BUS STOP850 TREG

SHEET 121 OF 318

O N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

I J J

I J J

KEY PLAN NO SCALE

G H E F

I J

A B C D scale 1”= 50’-0”

004 MID

A B

’-0

ALIGNED TO STONE FENCE PIER

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

NOTES:

REFER TO C-005 FOR FUEL EFFICIENT/ CAR POOL LOCATIONS AND NUMBERS.

NOTE: FIELD VERIFY ALL LOCATIONS AND COORDINATE WITH ALL UTILITIES.

NOTE: ALL SETBACKS 12’-0” FROM CURB UNLESS OTHERWISE NOTED.

TRAIL MARKERS ADDED EVERY 1/8 MILE ON TRAIL.

N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

NOTE: SEE PAGE XE-113B FOR CONTINUED

MESSAGE SCHEDULE AND SIGN QUANTITIES

NO SCALEA1 EXTERIOR MESSAGE SCHEDULE

FLOOR LOCATION SIGN TYPE MESSAGE SIDE A MESSAGE SIDE B NOTES SHEET LOCATION # MOUNTING

EXT 3 PDR

< EMERGENCY

South ACP

^ (375 PICTO)

NA XE-111-I FREE STANDING

EXT 4 MID

(logo) William Beaumont Army Medical Center

(logo) William Beaumont Army Medical Center XE-112-J FREE STANDING

EXT 8 TDR

^ After Hours Commercial Lane NA XE-111-I FREE STANDING

EXT 10 DLLC VISITOR CONTROL CENTER NA VCC XE-111-I ON CANOPY

EXT 12 SDR

^ ID Check Point Right Lanes

>Visitor Center

Have ID Ready

NA Verify message XE-111-I FREE STANDING

EXT 14 MED

EMERGENCY Hospital Clinics

NA XE-111-I GANTRY, STRUCTURAL

BEAMS

EXT 18 PDR

<EMERGENCY

Hospital / Clinic Service / Deliveries ^Hospital Drop-Off >Clinics Administration CIB / CUP Service / Deliveries

NA XE-110-H FREE STANDING

EXT 412 BSID sunmetro (logo) sunmetro (logo) BUS STOP XE-111-I MOUNT ON PYLON

EXT 432 IPL (CAMPUS MAP) NA BUS STOP XE-111-I mount on perforated panels

EXT 834

TREG

NO

SMOKING

(NO SMOKING PICTO)

NO SMOKING WITHIN 50' OF ALL BUILDING

ENTRANCES

XE-111-I on post

EXT 836

TREG

NO

SMOKING

(NO SMOKING PICTO)

NO SMOKING WITHIN 50' OF ALL BUILDING

ENTRANCES

XE-111-I on post

EXT 838

TREG

NO

SMOKING

(NO SMOKING PICTO)

NO SMOKING WITHIN 50' OF ALL BUILDING

ENTRANCES

XE-111-I on post

TREGEXT 850 [See layout on XE-132] SHUTTLE STOP MOUNT ON PYLONXE-110-H

SHEET 122 OF 318

SHEET 123 OF 318

O N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

Hospital Clinics

REPEAT PATTERN FOR PUNCHED OR EXPANDED METAL BASED ON WINDOW PATTERNS - TYPICAL

(MED) MAIN ENTRY IDENTIFICATION - ELEVATION

(MED) MAIN ENTRY IDENTIFICATION - CABINET DETAIL TYP. (MED) MAIN ENTRY IDENTIFICATION - CROSS SECTION TYP.

(MED) MAIN ENTRY IDENTIFICATION - PERFORATED METAL SCREEN

NO SCALE

(MED) MAIN ENTRY IDENTIFICATION - PERSPECTIVE VIEW

SIGN TYPE: (MED) MAIN ENTRANCE DIRECTIONAL - ILLUMINATED

A: MAIN TRUSS AND SUPPORTS

1’-0” SQUARE STEEL TUBEING

COLOR: PSE-4, MATTHEWS PAINT

MATCH PANTONE® 1545 U

FINISH: NON-GLARE (MATTE)

B: 1/4” THICK PERFORATED SCREEN

(OR RECOMMENDED THICKNESS FOR SIZE/STRENGTH)

PUNCHED OR WATER JET CUT ALUMINUM

NOTE: THIS SIGN (MED) HAS A LARGER PERFORATION PATTERN

THAN THE PARKING, BUS STOP AND SHUTTLE SIGNS.

BOLTED TO STRUCTURE WITH SS FLANGES HIDDEN TO

BACKSIDE OF STRUCTURE.

COLORS: PSE-9, MATTHEWS PAINT OR EQUIV.

MATCH PANTONE® 1545 U 50% TINT

FINISH: NON-GLARE (MATTE)

C: MAIN CABINETS -INTERNALLY ILLUMINATED

(WHITE LED’S)

WITH TRANSLUCENT ACRYLIC PUSH THRU LETTERS

FABRICATED FROM 1" SQUARE ALUMINUM TUBE

(ME-14) FRAME WITH 0.090" THICK ALUMINUM SHEETING

COLORS OF CABINETS:

1. EMERGENCY:

BACKGROUND: PSE-7

LETTERS: A-PTL

2. HOSPITAL:

BACKGROUND: PSE-5

LETTERS: A-PTL

3. CLINICS:

BACKGROUND: PSE-6

LETTERS: A-PTL

NOTES:

1) DAWN TO DUSK CONTROL VIA LOCAL PHOTOCELL

2) TRANSFORMER FROM 277V/1PH VOLTAGE TO THAT DEEMED

NECESSARY BY THE SIGNAGE FABRICATOR MANUFACTURER.

D: PUSH THRU ARROWS

TRANSLUCENT ACRYLIC

COLOR: ME-7

E: PUSH THRU LETTERING

1/2’ THICK TRANSLUCENT ACRYLIC

1’-0” HIGH CAP LETTERS

COLOR: ME-7

F: FOUNDATION:

DESIGN AND ENGINEERING OF FOOTINGS

ARE THE RESPONSIBILITY OF CONTRACTOR AND

SIGN MANUFACTURER.

SIGN CONTRACTOR TO SUBMIT SIGNED/SEALED

ENGINEERING DRAWINGS.

REFERENCE STRUCTURAL DRAWING S-001 GENERAL

STRUCTURAL NOTES.

CONTACT CONTRACTING OFFICER

FOR GEOTECHNICAL REPORT.

0 2'-0" 4'-0" 6'-0"

0 6" 1'-0" 1'-6"

0 1'-0" 2'-0" 3'-0"

FIELD VERIFY ALL DIMENSIONSADD VERTICAL BRACING WHERE NEEDED.

NOTE: CRASH BARRIERS

MAY BE REQUIRED

AROUND BASE

C1 (MED) MAIN ENTRY IDENTIFICATION - SECTIONC5

FOUNDATION DETAIL A4

B2 CABINET DETAIL - SECTION VIEWB3

A2

B1

A1

GRADE

LEVELING PLATE

BASE PLATE WELDED

TO STRUCTURAL SUPPORT

NOTE: ENGINEERING DRWGS

SUPERCEDE ALL DETAILS ON

THIS PAGE

RETAINER CLIPS

BOLT INTO BEAM

WEATHERPROOF PENETRATIONS

FACE 1/2” THICK

TRANSLUCENT WHITE ACRYLIC

PUSH THRU LETTERS AND ARROWS

WITH VINYL APPLIED

FIRST SURFACE AND WEEDED OUT

WHITE LED’S

DISCONNECT SWITCH

WEEP HOLES

(3 /4”

T

YP

1/

8"

TY

P.

4 5/8"

1 1/2"

5/8" 5/8"

1 1/2" 5/8"

1 1/2"

5/8" 5/8"

1 1/2" 1 1/2"

5/8" 5/8"

1 1/2"

5/8"

4 5/8" 2 3/4" 3 1/8" 4 3/8" 4 5/8"

1 3 /4"

TY

P.

NOTE: THIS SIGN (MED) HAS A LARGER PERFORATION PATTERN

THAN THE PARKING, BUS STOP AND SHUTTLE SIGNS.

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR

ILLUSTRATIVE PURPOSES ONLY.

ALL IMAGES AND CONTENT SHOWN ARE

FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR

ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

'-0

10'-0"

57'-0" (ADJUST WIDTH AS NEEDED)

43'-0" CURB TO CURB (VERIFY)

5'- 0"

EQ EQ EQ EQ

SIDE A

1'-0"

1'- 0"

5'- 0"

1'- 0"

1'- 1 1

/2" 7”

1'- 3"

1'- 0"

1'-0"1'-0" 1'-0"

1'- 0"

5'- 0"

10'-0"

10'-0" C

C

C

D

E

10'-0"

A

A

B

B

B

F

3/8” = 1’-0”

3/4” = 1’-0” 3/4” = 1’-0” NOT TO SCALE

1 1/2” = 1’-0”

3/8” = 1’-0”

NO SCALE

'-0

" M

IN

6'-0" MIN. EDGE OF CURB

RACEWAY BEHIND HORIZONTAL

STRUCTURAL BEAM

3'- 0"

6" (CAN BE WIDER

IF NEEDED)

SHEET 124 OF 318

O N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

William Beaumont Army Medical Center

1/2" = 1'-0"A1 SIDE ELEVATION

SIGN TYPE: (MID) MONUMENT IDENTIFICATION (INTERNALLY ILLUMINATED)

P. 1 of 2

NO SCALEC1 (MID) PERSPECTIVE

1/2" = 1'-0"A3 (MID) FRONT ELEVATION - MONUMENT IDENTIFICATION SIDE B

1/8" = 1'-0"D5 (MID) FRONT ELEVATION - SIDE A

1/2" = 1'-0"D2 (MON) TOP ELEVATION - MONUMENT IDENTIFICATION

E

A: MAIN BODY

2-SIDED ILLUMINATED

MATERIAL: ALUMINUM TUBE FRAME

(ME14) ALUMINUM SHEET SKIN

COLOR: PAINTED PSE-1

FINISH: NON-GLARE

NOTES:

1) PROVIDE ACCESS PANELS FOR MAINTENANCE

2) DAWN TO DUSK CONTROL VIA LOCAL PHOTOCELL

3) TRANSFORMER FROM 277V/1PH VOLTAGE TO THAT DEEMED

NECESSARY BY THE SIGNAGE FABRICATOR MANUFACTURER.

B: INSET

TINTED POLYCARBONATE PANELS ME-9

INSET 2" ON ALL SIDES FROM MAIN BODY

C: BASE:

PRECAST BASE WITH BUILDING STONE VENEER ME-10

(DSP-2 HONED FACE DIMENSION STONE PANELS).

REFER TO L-502 FOR VENEER STONE CONSTRUCTION DETAILS.

D: William Beaumont Army Medical Center LOGO (TBD)

SIZE: 12” HIGH

(ME-13) CAST ALUMINUM 1" THICK WITH

INFILLED PAINTED AREAS

EXACT LOGO AND COLORS TO BE PROVIDED BY CLIENT

MOUNTING: 1/2” DEEP SS STANDOFFS

E: FOUNDATION:

DESIGN AND ENGINEERING OF FOOTINGS

ARE THE RESPONSIBILITY OF CONTRACTOR AND

SIGN MANUFACTURER.

SIGN CONTRACTOR TO SUBMIT SIGNED/SEALED

ENGINEERING DRAWINGS.

REFERENCE STRUCTURAL DRAWING S-001 GENERAL

STRUCTURAL NOTES.

CONTACT CONTRACTING OFFICER

FOR GEOTECHNICAL REPORT.

LED ILLUMINATION

ON STREET SIDE, AND

BETWEEN PILLARS

G: William Beaumont Army Medical Center

LETTERS ROUTED OUT OF ALUMINUM FACE, FLUSH WITH SURFACE

WITH 3M DAY/NIGHT VINYL FILM FIRST SURFACE, SEE XE-118 DETAIL D4

SIZE: 12" HIGH X 11'-4 3/4" WIDE X 1/2" DEEP

TYPEFONT: CLEARVIEW HYWY 3-W

TRACKING: -50, ADJUST AS NEEDED

H: BUILDING ADDRESS LETTERS (TBD-VERIFY BEFORE PRODUCTION)

SIZE: 6" HIGH X 1/2" DEEP

(ME-1) ALUMINUM, WITH CLEAR ANODIZED FINISH

MATERIAL: WATER JET CUT ALUMINUM,

FINISH: FACE PAINTED: PSE-2

RETURNS PAINTED: PSE-3

PIN MOUNTED 1" OFF SURFACE, SS OR

NON-CORROSIVE HARDWARE

PINS PAINTED PSE-3

TYPEFONT: CLEARVIEW HYWY 3-W

TRACKING: +25

LED ILLUMINATION

BETWEEN PILLARS

LED ILLUMINATION

BETWEEN PILLARS

1/2" = 1'-0"A5 SIDE ELEVATION

STREET SIDE B

GRADE

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

0 1'-0" 2'-0" 4'-0"

William Beaumont Army Medical Center

ADADADADDADDDADDDADAADADDRDRDRDRDRDRRDRDRRDRRDRDRDRDRDRDRESESEESESESESSESESEESEESESESESEE SSSSSSSSSSSSS IFIFIFIFIFIFIIFIFIIF NNNNNNNNNNNNNNEEEEEEEEEEEEEEEEEEEEEDEDEDDEDEDEDEEEDEDEEEDEEEEEDDDDDDDDDDDDDDD

NOTE: ENGINEERING DRWGS SUPERCEDE ALL DETAILS ON THIS PAGE

B

B

B

2'-6" EQEQ

A

B

C H

D G

19'-5" 3'-2" 2'-8" 5'-9"

31'-0"

'-2

'-0

5'- 8"

2" 3'-

9'- 8"

3'-0"3'-0"

2'- 8"

1'- 8"

1'- 5 1

/8"

ADDRESS ALIGNED WITH NAME

2'- 3"

SHEET 125 OF 318

O N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

INTERNAL ILLUMINATION AREAS:

NAME AND TINTED POLYCARBONATE INSET

COLOR SHOWS AREA OF ILLUMINATION

ONLY - NOT COLOR OF LEDS

NOT TO SCALEB1

(MID) SECTION- PERSPECTIVE

ALUMINUM BODY

LED SIDE PANEL

LED BOTTOM PANEL

TRANSLUCENT POLYCARBONATE (LIGHT-

ED)

BUILDING STONE VENEER BASE

LAP BARS

GRADE

FOUNDATION

3" = 1'-0"C1 SECTION VIEW OF TOP

BODY PANELS

LIGHTED POLYCARBONATE PANELS

LED END COMPONENT

LED SIDE COMPONENTS

ACRYLIC DIFFUSER PANEL IF NEEDED

STEEL TUBE FRAME

0 3" 6" 9"

ADDRESS IF NEEDED

1/2" = 1'-0"A1 SECTION VIEW AA

SIGN TYPE: (MID) MONUMENT IDENTIFICATION (INTERNALLY ILLUMINATED)

P. 2 of 2

1/2" = 1'-0"A3 (MID) FRONT ELEVATION - MONUMENT IDENTIFICATION SIDE B

1/2" = 1'-0"D2 (MON) TOP ELEVATION - MONUMENT IDENTIFICATION

E

A: MAIN BODY

2-SIDED ILLUMINATED

MATERIAL: (ME-14) ALUMINUM TUBE FRAME

WITH 1/8” THICK ALUMINUM SHEET SKIN

COLOR: PAINTED PSE-1

FINISH: NON-GLARE

NOTE: PROVIDE ACCESS PANELS FOR MAINTENANCE

B: INSET

TINTED POLYCARBONATE PANELS ME-9

INSET 2" ON ALL SIDES FROM MAIN BODY

C: BASE:

PRECAST BASE WITH BUILDING STONE VENEER ME-10

(DSP-2 HONED FACE DIMENSION STONE PANELS).

D: William Beaumont Army Medical Center LOGO (TBD)

SIZE: 12” HIGH

(ME-13) CAST ALUMINUM 1" THICK WITH

INFILLED PAINTED AREAS

EXACT LOGO AND COLORS TO BE PROVIDED BY CLIENT

MOUNTING: 1/2” DEEP SS STANDOFFS

E: FOUNDATION:

DESIGN AND ENGINEERING OF FOOTINGS

ARE THE RESPONSIBILITY OF CONTRACTOR AND

SIGN MANUFACTURER.

SIGN CONTRACTOR TO SUBMIT SIGNED/SEALED

ENGINEERING DRAWINGS.

REFERENCE STRUCTURAL DRAWING S-001 GENERAL

STRUCTURAL NOTES.

CONTACT CONTRACTING OFFICER

FOR GEOTECHNICAL REPORT.

LED ILLUMINATION

ON STREET SIDE, AND

BETWEEN PILLARS

G: William Beaumont Army Medical Center

LETTERS ROUTED OUT OF ALUM. SKIN

WITH 3M DAY/NIGHT VINYL FILM, SEE XE-118 DETAIL D4

SIZE: 12" HIGH X 13'-4 7/8" APPROX. WIDE

TYPEFONT: CLEARVIEW HYWY 3-W

TRACKING: -50, ADJUST AS NEEDED

H: BUILDING ADDRESS LETTERS (TBD-VERIFY BEFORE PRODUCTION)

SIZE: 6" HIGH X 1/2" DEEP

(ME-1) ALUMINUM, WITH CLEAR ANODIZED FINISH

MATERIAL: WATER JET CUT ALUMINUM,

FINISH: FACE PAINTED: PSE-2

RETURNS PAINTED: PSE-3

PIN MOUNTED 1" OFF SURFACE, SS OR

NON-CORROSIVE HARDWARE

PINS PAINTED PSE-3

TYPEFONT: CLEARVIEW HYWY 3-W

TRACKING: +25

LED ILLUMINATION

BETWEEN PILLARS

LED ILLUMINATION

BETWEEN PILLARS

1/2" = 1'-0"A5 SECTION VIEW BB

STREET SIDE B

GRADE

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

0 1'-0" 2'-0" 4'-0"

B

B

B

2'-6" EQEQ

A

B

C

H

NOTE: ENGINEERING DRWGS SUPERCEDE ALL DETAILS ON THIS PAGE

D G

'-2

'-0

2"

9'- 8"

2'- 8"

1'- 8"

1'- 5 1

/8" 2'-

3"

19'-5" 3'-2"

5'- 8"

9" 1'-0" 9"

2'-6"

2'-6"

A

A

B

B

3'-2" 5'-9"

19'-4 7/8"

31'-0"

13'-4 1/2"

N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

SHEET 126 OF 318

1 1/2" = 1'-0"A2 (PDR) ELEVATION - PRIMARY DIRECTIONAL SIDE A

1 1/2" = 1'-0"D2 (PDR) PLAN VIEW - PRIMARY DIRECTIONAL

1 1/2" = 1'-0"A3 (PDR) SIDE ELEVATION - PRIMARY DIRECTIONAL

SIGN TYPE: PDR: PRIMARY DIRECTIONAL

INTERNALLY ILLUMINATED

p1 of 2

STREET SIDE A

0 6" 1'-0" 1'-6" NO SCALEA4 (PDR) PERSPECTIVE

0 6" 1'-0" 1'-6"

0 6" 1'-0" 1'-6"

A: MAIN BODY (ME-14)

2-SIDED ILLUMINATED (FLUORESCENT TUBE ILLUMINATION, 277v))

1/8” THICK ALUMINUM SKIN WITH TUBE STRUCTURE

COLOR: PAINTED PSE-1

DAY/NIGHT ILLUMINATED LETTERS.

FINISH: NON-GLARE (MATTE)

NOTES:

1) PROVIDE ACCESS PANELS FOR MAINTENANCE

2) DAWN TO DUSK CONTROL VIA LOCAL PHOTOCELL

3) TRANSFORMER FROM 277V/1PH VOLTAGE TO THAT DEEMED

NECESSARY BY THE SIGNAGE FABRICATOR MANUFACTURER.

B: LIGHTED ACCENT BAR (FLUORESCENT TUBE ILLUMINATION)

SIZE: 4’-8" WIDE X 2" HIGH X 9" DEEP

(ME-9) - TINTED TRANSLUCENT POLYCARBONATE

C: BASE

ME-11 CAST STONE BASE, MATCH TO BUILDING STONE OVERALL TONAL COLOR

(HONEY TUPELO).

FOOTINGS: DESIGN AND ENGINEERING OF FOOTINGS

ARE THE RESPONSIBILITY OF CONTRACTOR

AND SIGN MANUFACTURER.

SIGN CONTRACTOR TO SUBMIT SIGNED/SEALED

ENGINEERING DRAWINGS.

D: EMERGENCY PANEL VINYL GRAPHIC

WHITE VINYL LETTERS: (VE-5) WHITE

SIZE: 4 1/2” CAP HEIGHT

TYPEFONT: CLEARVIEW HYWY 3-W

TRACKING: +25

RED VINYL BAND:

SIZE: 7 3/4" HIGH X 5'-0" WIDE

COLOR: (VE-4) RED

E: FOUNDATION:

DESIGN AND ENGINEERING OF FOOTINGS

ARE THE RESPONSIBILITY OF CONTRACTOR AND

SIGN MANUFACTURER.

SIGN CONTRACTOR TO SUBMIT SIGNED/SEALED

ENGINEERING DRAWINGS.

REFERENCE STRUCTURAL DRAWING S-001 GENERAL

STRUCTURAL NOTES.

CONTACT CONTRACTING OFFICER

FOR GEOTECHNICAL REPORT.

F: PARKING ICON, VINYL GRAPHIC

SIZE: 6” DIAM.

COLOR: (VE-6) BLUE, (VE-5) WHITE

G: DIRECTIONAL ARROWS, VINYL GRAPHIC

SIZE: 4 1/2” DIAM. ON 6” DIAM. BLACK CIRCLE

COLORS: (V-3EXT) BLACK, (VE-5) WHITE

H: VINYL LETTERING

SIZE: 4 1/2” CAP HEIGHT

TYPEFONT: CLEARVIEW HYWY 3-W

TRACKING: +0

COLOR: (VE-8) DAY/NIGHT FILM

SEE PAGE XE-118 - DETAIL D4

I: VINYL LETTERING

SIZE: 2 1/2” CAP HEIGHT

TYPEFONT: CLEARVIEW HYWY 3-W

TRACKING: +0

COLOR: (VE-8) DAY/NIGHT FILM

SEE PAGE XE-118 - DETAIL D4

EMERGENCY

Hospital Patient Drop-Off

Parking

Administration

Patient Drop-Off

Service/ Deliveries

Clinics

1'- 2"

4 1 /2"

3" 2 1

/2" 2 1

/4" 4"

2"

'-0

2"

7 3 /4" be tw ee n cir cle s t yp

4 1/2"

6" DIAM.

F

G

2" 2'-

0"

C

E

H

I

7 3 /4"

D

A

B

2 1/2" 3"

5'-0"

NOTE: MESSAGE FOR POSITION ONLY, PLEASE SEE MESSAGE SCHEDULE FOR EXACT MESSAGES

NOTE: ENGINEERING DRWGS SUPERCEDE ALL DETAILS ON THIS PAGE

NOTE: RENDERING MAY NOT REFLECT EXACT DESIGN

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

9"

1'-6"

4 1 /2"

B

4'-8"

9 1 /4"

N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

1 1/2" = 1'-0"A2 A4(PDR) ELEVATION - PRIMARY DIRECTIONAL SIDE A

1 1/2" = 1'-0"D2 (PDR) PLAN VIEW - PRIMARY DIRECTIONAL

SIGN TYPE: PDR: PRIMARY DIRECTIONAL (INTERNALLY ILLUMINATED)

p2 of 2 NOTE: SAME CONSTRUCTION METHOD AS (MID) MAIN ID SIGN

(PDR) - PRIMARY DIRECTIONAL - SECTION

GRADE

POWER OUT BOTTOM, CENTER-CENTER.

PRIMARY POWER PROVIDED BY ELECTRICAL CONTRACTORS

PROVIDE ACCESS PANEL FOR MAINTENANCE

1" SQ. ALUMINUM TUBE

1" ALUMINUM ANGLE

3" SCHEDULE 40 STEEL POST

WITH 1 1/2” STEEL ANGLE SLEEVE

1" X 3 1/4" X 1/2" BREAKFORMED

(.125" THICK) ALUMINUM CHANNEL

0 6" 1'-0" 1'-6"

0 6" 1'-0" 1'-6"

0 6" 1'-0" 1'-6" 1 1/2" = 1'-0"

STEEL PLATE

COMPACTED OR UNDISTURBED SOIL

1'- 2"

4 1 /2"

3" 2 1

/2" 4"

2"

'-0

2"

7 3 /4" be tw ee n cir cle s t yp

4 1/2"

6" DIAM.

F

G

2" 2'-

0"

H

I 7 3

/4"

D

A

A

A: MAIN BODY

2-SIDED ILLUMINATED (FLUORESCENT TUBE ILLUMINATION, 277v))

(ME-14) ALUMINUM SKIN 1/8” THICK WITH ROUTED FLUSH LETTERS

COLOR: PAINTED (PSE-1)

FINISH: NON-GLARE

B: LIGHTED ACCENT BAR (FLUORESCENT TUBE ILLUMINATION)

ME-9 TINTED POLYCARBONATE PANELS

C: BASE:

ME-11 CAST STONE BASE, MATCH TO BUILDING STONE

OVERALL TONAL COLOR (HONEY TUPELO)

D: EMERGENCY PANEL (FLUORESCENT TUBE ILLUMINATION), VINYL GRAPHIC

WHITE VINYL LETTERS: (VE-5) WHITE

SIZE: 4 1/2” CAP HEIGHT

TYPEFONT: CLEARVIEW HYWY 3-W

KERNING: OPTICAL (ILLUSTRATOR), TRACKING: +25

RED VINYL BAND:

SIZE: 7 3/4" HIGH X 5'-0" WIDE

COLOR: (VE-4) RED

E: FOUNDATION:

DESIGN AND ENGINEERING OF FOOTINGS

ARE THE RESPONSIBILITY OF CONTRACTOR AND

SIGN MANUFACTURER.

SIGN CONTRACTOR TO SUBMIT SIGNED/SEALED

ENGINEERING DRAWINGS.

REFERENCE STRUCTURAL DRAWING S-001 GENERAL

STRUCTURAL NOTES.

CONTACT CONTRACTING OFFICER

FOR GEOTECHNICAL REPORT.

F: PARKING ICON, VINYL GRAPHIC

SIZE: 6” DIAM.

COLOR: (VE-6) BLUE, (VE-5) WHITE

G: DIRECTIONAL ARROWS, VINYL GRAPHIC

SIZE: 4 1/2” DIAM. ON BLACK 6“ DIAM CIRCLE

COLORS: (VE-3) BLACK, (VE-5) WHITE

H: VINYL LETTERING

SIZE: 4 1/2” CAP HEIGHT

TYPEFONT: CLEARVIEW HYWY 3-W

KERNING: OPTICAL (ILLUSTRATOR), TRACKING: +0

COLOR: (VE-8) DAY/NIGHT FILM; DETAIL D4.

I: VINYL LETTERING

SIZE: 2 1/2” CAP HEIGHT

TYPEFONT: CLEARVIEW HYWY 3-W

KERNING: OPTICAL (ILLUSTRATOR), TRACKING: +0

COLOR: (VE-8) DAY/NIGHT FILM; DETAIL D4

NO SCALEC1

(PDR) DETAIL A - SECTION VIEW

9"

1'- 6"

SS 3/4” THICK METAL BASE PLATE

BOLTED TO THREADED LAP BARS (AS

NEEDED) IN CONCRETE BASE

STREET SIDE A

NO SCALEA1 SECTION CUT AWAY VIEW

SIDE ILLUMINATED

PANELS ARE INSETINTERNAL ILLUMINATION AREAS: NAME AND TINTED POLYCARBONATE INSET

COLOR SHOWS AREA OF ILLUMINATION ONLY - NOT COLOR OF LIGHTS

NOTE: MESSAGE FOR POSITION ONLY, PLEASE SEE MESSAGE SCHEDULE FOR EXACT MESSAGES

FIBERGLASS BODY

TRANS. POLYCARBONATE PANELS

FLUORESCENT TUBE LIGHTING

FLUORESCENT SIDE LIGHTING

ACRYLIC DIFFUSER PANEL IF NEEDED

STEEL TUBE FRAME

ALUMINUM BODY

FLUORESCENT TUBE SIDE PANEL

FLUORESCENT TUBE BOTTOM PANEL

TRANSLUCENT POLYCARBONATE (LIGHT-

ED)

CAST STONE ON CONCRETE BASE

LAP BARS

GRADE

FOOTINGS

NOTE: ENGINEERING DRWGS SUPERCEDE ALL DETAILS ON THIS PAGE

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

NO SCALED4 SECTION DETAIL

SIGN FACE

ACRYLIC/VINYL

FLUSH WITH FACE

TOP RETAINER CLIP

BOTTOM RETAINER CLIP

SECTION DETAIL

1/4" THK. (MIN.) WHITE

TRANSLUCENT ACRYLIC BACKER

RETAINER CLIPS ON ALL LETTER CENTERS

(NOT SOLVENT WELDED)

A

H, I

1/2" THK. (MIN.) WHITE

TRANSLUCENT ACRYLIC, FLUSH WITH SURFACE

VINYL FIRST SURFACE

SHEET 127 OF 318

B

C

C

B

2 1/2"

2 1/2"

3"

5'-0"

FROM EDGES

SIDE ILLUMINATED

PANELS ARE INSET

1 1/2" = 1'-0"A2 (SDR) FRONT ELEVATION - SECONDARY DIRECTIONAL

C3 (SDR) PLAN VIEW - SECONDARY DIRECTIONAL

1 1/2" = 1'-0"A3 (SDR) SIDE ELEVATION - SECONDARY DIRECTIONAL

SIGN TYPE: SDR: SECONDARY DIRECTIONAL ILLUMINATED

NOTE: SAME CONSTRUCTION AS (PDR) PRIMARY DIRECTIONAL

0 6" 1'-0" 1'-6"

0 6" 1'-0" 1'-6"

1 1/2" = 1'-0"A4 (SDR) SECTION VIEW - SECONDARY DIRECTIONAL

SIDE ILLUMINATED

PANELS ARE INSET

GRADEGRADE

COMPACTED OR UNDISTURBED SOIL

TO CODE

3" SCHEDULE 40 STEEL POST

WITH 1 1/2" STEEL ANGLE SLEEVE

1" X 3 1/4" X 1/2" BREAKFORMED

(.125" THICK) ALUMINUM CHANNEL

1 1/2" = 1'-0"

STREET SIDE A

Line If NeededLine If Needed

EMERGENCY

Hospital Patient Drop-Off

Line If NeededLine If Needed

Parking

Service/ Deliveries

Patient Drop-Off

Administration

Clinics

PROVIDE HINGED SIDE ACCESS PANEL

A: MAIN BODY

2-SIDED ILLUMINATED (FLUORESCENT TUBE ILLUMINATION, 277v))

ALUMINUM SKIN 1/8” THICK WITH ROUTED FLUSH LETTERS

COLOR: PAINTED (PSE-1)

FINISH: NON-GLARE

NOTES:

1) PROVIDE ACCESS PANELS FOR MAINTENANCE

2) DAWN TO DUSK CONTROL VIA LOCAL PHOTOCELL

3) TRANSFORMER FROM 277V/1PH VOLTAGE TO THAT DEEMED

NECESSARY BY THE SIGNAGE FABRICATOR MANUFACTURER.

B: LIGHTED ACCENT BAR (FLUORESCENT TUBE ILLUMINATION)

ME-9 TINTED POLYCARBONATE PANELS

C: BASE:

ME-11 CAST STONE BASE

MATCH TO BUILDING STONE OVERALL TONAL COLOR

(HONEY TUPELO)

FOOTINGS: DESIGN AND ENGINEERING OF FOOTINGS

ARE THE RESPONSIBILITY OF CONTRACTOR

AND SIGN MANUFACTURER.

SIGN CONTRACTOR TO SUBMIT SIGNED/SEALED

ENGINEERING DRAWINGS.

D: EMERGENCY PANEL (ILLUMINATED), VINYL GRAPHIC

WHITE VINYL LETTERS: VE-5 WHITE

SIZE: 3” CAP HEIGHT

TYPEFONT: CLEARVIEW HYWY 3-W

TRACKING: +0

RED VINYL BAND:

SIZE: 5 1/4" HIGH X 3'-4" WIDE

COLOR: VE-4 RED

E: FOUNDATION:

DESIGN AND ENGINEERING OF FOOTINGS

ARE THE RESPONSIBILITY OF CONTRACTOR AND

SIGN MANUFACTURER.

SIGN CONTRACTOR TO SUBMIT SIGNED/SEALED

ENGINEERING DRAWINGS.

REFERENCE STRUCTURAL DRAWING S-001 GENERAL

STRUCTURAL NOTES.

CONTACT CONTRACTING OFFICER

FOR GEOTECHNICAL REPORT.

F: PARKING ICON, VINYL GRAPHIC

SIZE: 4 1/4” DIAM.

COLOR: V-6EXT, VE-5 WHITE

G: DIRECTIONAL ARROWS, VINYL GRAPHIC

SIZE: 4 1/4" DIAM.

COLORS: VE-3 BLACK, VE-5 WHITE

H: VINYL LETTERING

SIZE: 4 1/2” CAP HEIGHT

TYPEFONT: CLEARVIEW HYWY 3-W

TRACKING: +0

COLOR: VE-8 DAY/NIGHT FILM; SEE PAGE XE-118 DETAIL D4

I: VINYL LETTERING

SIZE: 2 1/2” CAP HEIGHT

TYPEFONT: CLEARVIEW HYWY 3-W

TRACKING: +0

COLOR: VE-8 DAY/NIGHT FILM; SEE PAGE XE-118 DETAIL D4

G

NOTE: SAME CONSTRUCTION AS

(PDRI) PRIMARY DIRECTIONAL

NOTE: MESSAGE FOR POSITION ONLY, PLEASE SEE MESSAGE SCHEDULE FOR EXACT MESSAGES

NO SCALEC2 (SDR) DETAIL A - SECTION VIEW

SIDE ILLUMINATED

PANELS ARE INSET

ALUMINUM BODY

TRANS. POLYCARBONATE PANELS

FLUORESCENT TUBE LIGHTING

FLUORESCENT SIDE LIGHTING

ACRYLIC DIFFUSER PANEL IF NEEDED

STEEL TUBE FRAME

NOTE: ENGINEERING DRWGS SUPERCEDE ALL DETAILS ON THIS PAGE

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

SHEET 128 OF 318

C O N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

3'-4"

6'- 8"

3"

1'-3/8"

6 1/8"

1'- 3/8

6 1 /8"

2"

5/

8"

2 1/2" 2 1/2"2 1/8"

5 1 /4"

1/

2"

4 1/4" DIAM.

4 1/4" DIAM.

1 3 /8"

1 3/8"

1'- 4"

5'- 2 3

/4"

3'-1 1/4"

3'-4"

F

H

I

D

B

C

A

E

C

A

1 1/2" = 1'-0"A4 (TDR) TERTIARY DIRECTIONAL - SECTION VIEW

0 6" 1'-0" 1'-6"

GRADE

COMPACTED OR UNDISTURBED SOIL

CONCRETE FOOTING

3" SCHEDULE 40 STEEL POST

WITH 1 1/2" STEEL ANGLE SLEEVE

1" X 3 1/4" X 1/2" BREAKFORMED

(.125" THICK) ALUMINUM CHANNEL

TINTED POLYCARBONATE PANEL

NON-ILLUMINATED

Line If NeededLine If Needed

Parking

Hospital Patient Drop-Off

Line If NeededLine If Needed

Parking

Patient Drop-Off

Line If NeededLine If Needed

Administration

Clinics

SIGN TYPE: (TDR) TERTIARY DIRECTIONAL (NON-ILLUMINATED)

1 1/2" = 1'-0"A1 (TDR) TERTIARY DIRECTIONAL -ELEVATION

C2 (TDR) TERTIARY DIRECTIONAL - PLAN VIEW

0 6" 1'-0" 1'-6"

0 6" 1'-0" 1'-6" 1 1/2" = 1'-0"

1 1/2" = 1'-0"A3 (TDR) TERTIARY DIRECTIONAL - SIDE VIEW

0 6" 1'-0" 1'-6"

A: MAIN BODY

2-SIDED ALUMINUM .090 THICK

COLOR: PAINTED PSE-1 WITH VINYL FIRST SURFACE GRAPHICS

FINISH: NON-GLARE (MATTE)

B: ACCENT BAR (NOT ILLUMINATED)

(ME-9) TINTED POLYCARBONATE

SIZE: 1’-0" WIDE X 1" HIGH 4 1/2" DEEP

C: BASE

ME-11 CAST STONE BASE - TBD

MATCH TO BUILDING STONE OVERALL TONAL COLOR

(HONEY TUPELO)

E: FOUNDATION:

DESIGN AND ENGINEERING OF FOOTINGS

ARE THE RESPONSIBILITY OF CONTRACTOR AND

SIGN MANUFACTURER.

SIGN CONTRACTOR TO SUBMIT SIGNED/SEALED

ENGINEERING DRAWINGS.

REFERENCE STRUCTURAL DRAWING S-001 GENERAL

STRUCTURAL NOTES.

CONTACT CONTRACTING OFFICER

FOR GEOTECHNICAL REPORT.

F: PARKING ICON, VINYL GRAPHIC

SIZE: 3 1/4” DIAM.

COLOR: (VE-10) BLUE, (VE-1) REFLECTIVE WHITE

G: DIRECTIONAL ARROWS, VINYL GRAPHIC

SIZE: 4 1/2” DIAM.

COLORS: (VE-3) BLACK, (VE-1) REFLECTIVE WHITE

H: VINYL LETTERING

SIZE: 2 1/4” CAP HEIGHT

TYPEFONT: CLEARVIEW HYWY 3-W

TRACKING: +0

COLOR: (VE-3) BLACK

I: VINYL LETTERING

SIZE: 2 1/2” CAP HEIGHT

TYPEFONT: CLEARVIEW HYWY 3-W

TRACKING: +0

COLOR: (VE-3) BLACK

9"

ADJUST TRACKING

TO FIT

Line If NeededLine If Needed

Parking

After Hours Commercial Lane

1 1/2" = 1'-0"C4 (TDR) TERTIARY DIRECTIONAL -ALT. MESSAGE

0 6" 1'-0" 1'-6"

SIDE PANELS

ARE INSET

NOTE: ENGINEERING DRWGS SUPERCEDE ALL DETAILS ON THIS PAGE

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

4 1/2"

2'-6"

3'-

1'-

0" 1"

5'- 0"

3 1/4" DIAM.

2 1 /4"

3 3 /4"

2 1 /4"

1 1 /2"

1 1 /4"

1" 1"

1"

2'-4" 2 1/4"

1"

F

G

H

I

A

B

B

C

E

B

C

2'-4" 1"

3 3 /4"

2 3 /4"

C

AP

H

EI

GH

T

1 1 /2"

C O N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

SHEET 129 OF 318

SHEET 130 OF 318

O N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

A1

SHUTTLE

STOP

3/8" = 1'-0"C4 (BSID) (IPL) (SSID) LOCATIONS

1 1/2" = 1'-0"C2 (SSID) SHUTTLE STOP IDENTIFICATION - ELEVATION

1/2" = 1'-0"B3 WINDBREAK PANELS

SIGN TYPE: (SSID) SHUTTLE STOP IDENTIFICATION

SIGN TYPE: (SSID) SHUTTLE STOP IDENTIFICATION

A1: SHUTTLE STOP 2 SIDED (BOTH SIDES IDENTICAL)

(PATTERN, MATERIAL AND CONSTRUCTION SAME AS WINDBREAK PATTERNS ON

PEDESTRIAN WALKWAYS AND BUS SHELTERS)

REFERENCE SHEET LS-111.1A - DETAIL B1 AND LS111.2A - DETAIL B1

FOR LOCATION.

1/8” THICK PERFORATED ALUMINUM PUNCH PATTERN WITH EDGE BAND

(PATTERN SAME AS WINDBREAK PATTERNS ON PEDESTRIAN WALKWAYS)

FINISH: PSE-9, PAINTED BOTH SIDES

BLUE CIRCLE: 1/8” THICK ALUMINUM

PAINT: PSE-10

WHITE VINYL GRAPHICS: VE-2

A2: PYLON, ALUMINUM TUBE FRAME WITH 1/8” THICK ALUMINUM SKIN

18’-0“ H X 2’-0” W X 6“ DEEP

FINISH: MATCH CANOPY; ME16

SIGN TYPE: (IPL)

B: SHUTTLE/BUS/TRAIL SHELTER: ONE CAMPUS OR TRAIL MAP EACH

LOCATION. (SIZE & GRAPHICS TO BE FINALIZED DURING SUBMITTAL PHASE)

SIZE: 3’-0” W X 4’-0” H

MATERIAL: ( ME-8 )

HIGH PRESSURE DIGITAL LAMINATE PANEL

(PHENOLIC RESIN PANEL)

UV PROTECTED, EXTERIOR GRADE, SINGLE SIDED

1" WITH DIGITALLY PRINTED GRAPHICS MOUNTED WITH

CONCEALED CLEAT FASTENERS TO WINDBREAK PANELS (TBD)

EDGES PAINTED BLACK PSE-3

TYPEFONT: DIN-OT MEDIUM AND DIN-OT REGULAR

KERNING: OPTICAL (ILLUSTRATOR), TRACKING: VARIES

0 6" 1'-0" 1'-6"

1 1/2" = 1'-0"A1 (BSID) BUS STOP IDENTIFICATION - ELEVATION

0 6" 1'-0" 1'-6"

1 1/2" = 1'-0"C3 (SSID) - SIDE VIEW

0 6" 1'-0" 1'-6" 0 2'-0" 4'-0" 6'-0" 3/8" = 1'-0"C5 (BSID) (IPL) (SSID) LOCATIONS

A1

A2

C

INFORMATIONAL SIGN TBD

NOTE: REFER TO L-504 FOR BUS SHELTER CONSTRUCTION

1 1/2" = 1'-0"A3 (BSID) - SIDE VIEW

0 6" 1'-0" 1'-6" NO SCALEA5 (BSID) - PERSPECTIVE VIEW

6”

8”

SUNMETRO LOGO TO BE PROVIDED BY CLIENT

ROLLED EDGE

1/4” THICK ALUMINUM SHEET,

PAINTED PSE-2 BOTH SIDES

1/4” THICK PERFORATED ALUMINUM SHEET,

PAINTED PSE-2 BOTH SIDES

SS CONNECTOR RODS 1” DIAM. x _ ” LONG, BOLTED THROUGH BOTH SIDES (AS NEEDED)

WITH SS SPACERS 1” DIAM. X 1” LONG, BOTH PAINTED PSE-2

SIGN TYPE: (BSID) METROSUN BUS STOP IDENTIFICATION

C: 2 SIDED

MOUNTED ON RECTANGULAR ALUMINUM TUBE,

(8” W X 3“ THICK ) SCREWED TO PYLON

CONTRACTOR TO PROVIDE ALL WEATHER RESISTANT

ATTACHMENTS AND CONNECTORS.

PERFORATED ALUMINUM PUNCH PATTERN WITH EDGE BAND

(PATTERN, MATERIAL AND CONSTRUCTION SAME AS WINDBREAK PATTERNS ON

PEDESTRIAN WALKWAYS AND BUS SHELTERS)

FINISH: PSE-2, PAINTED BOTH SIDES

D: SUN METRO LOGO (PROVIDED BY CLIENT)

1/4” THICK WATERJET CUT ALUMINUM CIRCLE, 2’-7“ DIAM.

LETTERS ME-1: BLUE LETTERS TO BE 1/2” THICK (FLUSH WITH WHITE LETTERS)

PAINTED TO MATCH LOGO COLORS.

WHITE LETTERS 1/4” THICK PAINTED P-2

D D

D

3'- 6" 2'- 9"

4"

3/ 4"

3" 4"

2" 4"

4" 9"

1 3/4"

Ø 2'-7"

3'- 0"

7'-4 1/4"

4"

2 1/2"

F

1/4” THICK ALUMINUM SHEET,

PAINTED PSE-9 BOTH SIDES

1 1/2" = 1'-0"B5 (IPL) INTERPRETIVE PANEL

B

4'-0"

3'-0"

WIND BREAK PANELS

F: REFERENCE SHEET S-01-BS FOR DETAILS ON WINDBREAK PANELS.

MAINTAIN MINIMUM 1/2” SOLID AREA ON ALL SIDES AND EDGES.

1/4” THICK (ME-1) ALUMINUM

NOTE: FRAME WORK WILL BE INDEPENDANT OF PIERS ON CANOPIES.

FINISH: DURANAR SUNSTORM

COLOR: GALAXY SILVER

FOUNDATION:

DESIGN AND ENGINEERING OF FOOTINGS

ARE THE RESPONSIBILITY OF CONTRACTOR AND

SIGN MANUFACTURER.

SIGN CONTRACTOR TO SUBMIT SIGNED/SEALED

ENGINEERING DRAWINGS.

REFERENCE STRUCTURAL DRAWING S-001 GENERAL

STRUCTURAL NOTES.

CONTACT CONTRACTING OFFICER

FOR GEOTECHNICAL REPORT.

B

REPEAT PATTERN FOR PUNCHED OR EXPANDED METAL

BASED ON WIND SCREENS - TYPICAL

OPEN AT BOTTOM TO ALLOW

SAND TO FALL THROUGH

PERFORATED METAL SCREEN - DETAILB2

12” = 1’-0”

1/4"1/2"

1/ 2"

NOTE: MAINTAIN 1/2" EDGE ( NO PERFORATIONS) ALL SIDES

(BOTTOM CAN BE WIDER)

1/8" 1/8"1/4"1/8" 1/4"1/8" 1/8"1/4"

1/8" 3/4"

1/

4"

1/ 4"

1/

4"

1/8" 1/2"1/ 2"

1/ 4"

0 1'-0" 2'-0" 4'-0"

SHUTTLE

STOP

2’-0”

3’- 6”

7’- 0”

’-0

9”

1’-0”

A1

A2

ILLUMINATED SIGN

BY SUNMETRO

POWER PROVIDED

BY GENERAL

CONTRACTOR

CENTERED

A2

FOR POSITION ONLY

FOR POSITION ONLYADVERTISING

PANELS – TBD

ADVERTISING

PANELS – TBD

ADVERTISING

PANELS – TBD

ADVERTISING

PANELS – TBD

A2

A2

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

0 1" 2" 4"

BRACKETS AS NEEDED

PAINTED PSE-4

A2

NOTE: ENGINEERING DRWGS SUPERCEDE ALL DETAILS ON THIS PAGE

2’-0” FROM CURB.

REFERENCE SHEET LS-111.1A -

DETAIL B1 AND LS111.2A - DETAIL B1

FOR LOCATION.

REFERENCE SHEET LS-111.1A -

DETAIL B1 AND LS111.2A - DETAIL B1

FOR LOCATION.

6 1 /4"

87°

6"

10"

1"

SHEET 131 OF 318

A D D E N D U M

A

D E N D U M

C O N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

3/4" = 1'-0"C2 (DLLC) DIMENSIONAL LETTERING AT VISITOR’S CENTER - DETAIL

(DLLC) DIMENSIONAL LETTERS ENTRANCE

SIGN SPECIFICATIONS

A: CLINIC: ADDRESS LETTERS

SIZE: 2’-0" HIGH X 1/2" DEEP

MATERIAL: WATER JET-CUT ALUMINUM LETTERS, ME-1

FINISH: PAINT FACE AND RETURNS

RETURNS: NATURAL SATIN FINISH

( PSE-3 ) JET BLACK NON-GLARE (MATTE)

MOUNTING: FLUSH MOUNTED ON BUILDING USING SS OR NON-CORROSIVE HARDWARE

PIN MOUNT W/EPOXY, WEATHERPROOF ALL PENETRATIONS

TYPEFONT: CLEARVIEW HIGHWAY 6B

B, C, D: ALL FABRICATED CHANNEL LETTERS MOUNTED TO CANOPY

LETTERS MUST BE LEVEL AND PLUM.

ROUNDED PORTION OF LETTERS TO BE SHAVED TO

AVOID VERTICAL SHIFT.

MATERIAL: FABRICATED, FULLY ENCLOSED .063 ALUMINUM

HOLLOW LETTERS, NO EXPOSED FASTENERS.

WELDS TO BE GRINDED SMOOTH.

PROVIDE NECESSARY INTERNAL BRACING

TO PREVENT WARPING.

FINISH: PAINT FACE ONLY

( PSE-3 ) JET BLACK NON-GLARE (MATTE)

RETURNS: NATURAL SATIN FINISH

MOUNTING: BOLTED TO TOP OF CANOPY,

LETTERS MUST BE LEVEL AND PLUM.

ROUNDED PORTION OF LETTERS TO BE SHAVED TO

AVOID VERTICAL SHIFT.

TYPEFONT: CLEARVIEW HIGHWAY 6B

B: CLINIC: FABRICATED CHANNEL LETTERS MOUNTED TO CANOPY

SIZE: 2’-0" HIGH X 4" DEEP

C: VISITOR’S CENTER:

SIZE: 1’-0” HIGH x 2” DEEP

FABRICATED CHANNEL LETTERS MOUNTED TO CANOPY

FINISH, MATERIAL, FABRICATION AND SAME AS ON CLINICS (B) EXCEPT FOR SIZE

D: ADMINISTRATION

SAME HEIGHT / DETAILS AS CLINIC LETTERS (B) 0 6" 1'-0" 1'-6"

1/4" = 1'-0"D2 (DLLC) DIMENSIONAL LETTERING AT VCC - FRONT ELEVATION

1/4" = 1'-0"D4 (DLLC) DIMENSIONAL LETTERING AT VCC - NORTH ELEVATION

23'-0" APROX.

1'- 0"

C

AP

H

EI

GH

T

VISITOR CONTROL CENTER

0 2'-0" 4'-0" 8'-0"

CENTER ON CANOPY

DESIGN INTENT DOCUMENT.

ENGINEERING DETAILS SHOWN FOR ILLUSTRATIVE PURPOSES

ONLY.

ALL IMAGES AND CONTENT SHOWN ARE FOR LAYOUT ONLY.

FINAL APPROVED MESSAGES TO APPEAR ON SIGN MESSAGE

SCHEDULE UNLESS STATED OTHERWISE.

SHAVE OFF BOTTOM OF LETTERS

TO BE FLUSH WITH BOTTOM

VISITOR CONTROL CENTER

C

C

C

N F O R M A N C E

S

N F O R M A N C E

S

W G R

W G R

CO

NF

O

RM

AN

CE

SE

T

GRADE

COORDINATE WITH OTHERS FOR

FINISH TO SURFACE IE:

CONCRETE OR DIRT SURFACE.

COMPACTED OR UNDISTURBED SOIL

SIGN POST INSTALLATION

GRADE

COMPACTED OR UNDISTURBED SOIL

TYPICAL POLE SIGN BRACKET/HARDWARE

NTS

Typical Sign Frames

NTS

LE

NG

TH

A

LE

NG

TH

B

LE

NG

TH

C

NOTE: THIS DRAWING IS TO SHOW DESIGN INTENT ONLY EXACT

LOCATIONS PER GENERAL CONTRACTOR AND DOT STANDARDS

DECORATIVE TRAFFIC SIGNS:

"SPECIAL LITE PRODUCTS" PRE-FABRICATED BACK PLATES OR EQUAL.

CAST ALUMINUM PLATES TO ALLOW FOR STANDARD .090

ALUMINUM INSERTS (DOT APPROVED) AT VARIOUS SIZES AND SHAPES.

FINISH: TPP: THERMOSET POLYESTER POWDERCOAT

COLOR: GM-GUN METAL

MOUNTING BRACKETS AND POLE FOOTINGS

TO BE SPECIFIED BY SIGNAGE GENERAL CONTRACTOR TO LOCAL CODE

ALL HARDWARE TO BE WEATHER DURABLE AND TAMPER RESISTENT.

USE BREAK AWAY BASE AS NEEDED

USE BREAK AWAY BASE AS NEEDED

1" = 1'-0"B1 (TREG) TRAFFIC REGULATORY - TALL POST

0 6" 1'-0" 1'-6" 1" = 1'-0"B2 (TREG) TRAFFIC REGULATORY - SHORT POST

0 6" 1'-0" 1'-6"

NOT TO SCALEA4 (TREG) TRAFFIC REGULATORY - DETAILS

SF24-OCT

Sign Frame

24” STOP/DOT SIGN

3” or 4” O/D ROUND POST

POLE HEIGHT

AVAILABLE IN

10 FT., 12 FT,

14 FT. AND 16 FT.

POLE HEIGHT

AVAILABLE IN

10 FT., 12 FT,

14 FT. AND 16 FT.

OPTIONAL SIGN BLADES

BA-4** Smooth Wall Post

- 3” or 4” O/D Round Post

- Made of Extruded Aluminum

- .095 Wall Thickness

- Direct Burial, break away pole

TRO - Street Sign Bracket

- Fits 3” O/D round posts. Holds one street blade.

- Available for flat and extruded sign blades

- Item # TRO-X for extruded blade

- Made of Cast Aluminum (See Traffic Pole Accessories Section for product specifications)

DBL - Double Street Sign Bracket

- Fits onto a Street Blade. Holds one Street Blade.

- Available for flat and extruded sign blades

- Item # DBL-X for extruded blade

- Made of Cast Aluminum (See Traffic Pole Accessories Section for product specifications)

SF24-OCT Sign Frame

- Fits around 24” Stop Sign

- Has a 1” square edge on all sides

- Made of Cast Aluminum

Finish

- The fixture will be finished with a premium quality thermoset polyester powdercoat for a durable finish.

(3” O/D Fluted Pole w/ Street…