About this file

Amendment No. 0002

View the file

Other files

File Type Posted
Amend-0007-W9126G17B0023.pdf PDF
g17b0023_0006.pdf PDF
g17b0023_0004.pdf PDF
Amend-0003-W9126G17B0023.pdf PDF
AMEND-0001_W9126G17B0023.pdf PDF
W9126G17B0023-Plans.pdf PDF
W9126G17B0023-Specs.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W45VAK71306009 007140

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

Unrestricted Procurement for Gulf Intracoastal Waterw ay, Texas, Main Channel from High Island to Rollover Pass in Chambers and Galveston Counties, Texas, Pipeline Dredging in w hich bid opening is scheduled for 25 Aug 17 at 2:00 PM (CST) is hereby amended as follow s:

Continued on Page 2.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 3

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W9126G17B0023

X 9B. DATED (SEE ITEM 11)

26-Jul-2017

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

22-Aug-2017

CODE

US ARMY CORPS OF ENGINEERS FORT WORTH

2000 FORT POINT ROAD

GALVESTON TX 77550-1229

W9126G 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W9126G17B0023

A0002-2

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

1. The specifications for Solicitation No. W9126G17B0023, Gulf Intracoastal Waterway, Texas, Main Channel from High Island to Rollover Pass in Chambers and Galveston Counties, Texas, Pipeline Dredging, are hereby amended as follows:

a) Specifications.

(1) SECTION 35 20 23.16 45, PIPELINE DREDGING, APPENDIX 1 – QUANTITY

SUMMARY TABLE – The enclosed SECTION 35 20 23.16 45, entitled PIPELINE DREDGING, APPENDIX 1 – QUANTITY SUMMARY TABLE, supersedes that issued with Amendment No. 0001.

b) Drawings.

(1) DRAWINGS NO. C-01 – In the PLAN VIEW change the callout, “PLACEMENT AREA NO.

43 DISCHARGE CORRIDOR SEE SHT C-18 FOR DETAILS to “PLACEMENT AREA

NO. 43 DISCHARGE CORRIDOR SEE SHT C-16 FOR DETAILS”.

2. This amendment shall be attached to and become a part of the solicitation.

1 Encls:

1. SECTION 35 20 23.16 45, SECTION 35 20 23.16 45, APPENDIX 1 – QUANTITY SUMMARY

TABLE

SWG FILE NO.:IWW 1101-294 SOLICITATION NO.:W9126G-17-B-0023

Section 35 20 23.16 45 - Page A-1

(TO ACCOMPANY AMENDMENT NO. 0002 TO SOLICITATION NO. W9126G17B0023)

Side Slope

Required Depth

(CY)

Allowable Overdepth

(CY)

Total Estimated

(CY)

1 162+204 168+000 5,796 125 17 2H:1V 1 33,000 18,000 51,000 28 2 168+000 174+400 6,400 125 17 2H:1V 1 40,000 14,000 54,000 28 3 187+000 192+000 5,000 125 17 2H:1V 1 25,000 13,000 38,000 33 4 192+000 197+000 5,000 125 17 2H:1V 1 35,000 12,000 47,000 33 5 197+000 202+000 5,000 125 17 2H:1V 1 50,000 17,000 67,000 35 6 202+000 207+000 5,000 125 17 2H:1V 1 25,000 23,000 48,000 35

7 207+000 212+000 5,000 125 17 2H, 5H:1V 1 15,000 28,000 43,000 35

37,196 223,000 125,000 348,000

13 315+000 320+000 5,000 260-556 17 5H:1V 1 115,000 42,000 157,000 42 14 320+000 321+000 1,000 269-591 17 5H:1V 1 126,000 21,000 147,000 43

6,000 241,000 63,000 304,000

43,196 464,000 188,000 652,000

10 222+000 227+000 5,000 125 17 2H:1V 1 32,000 21,000 53,000 36 11 227+000 232+000 5,000 125 17 2H:1V 1 28,000 21,000 49,000 36 12 232+000 237+000 5,000 125 17 2H:1V 1 32,000 20,000 52,000 36

15,000 92,000 62,000 154,000

15 -00+30 10+00 1,030 204 22 2H:1V 2 84,000 16,000 100,000 43 1,030 84,000 16,000 100,000

8 212+000 217+200 5,200 125 17 5H:1V 2 97,000 49,000 146,000 Rollover Beach 9 217+200 222+000 4,800 125 17 2H:1V 2 49,000 38,000 87,000 Rollover Beach

10,000 146,000 87,000 233,000

8 212+000 217+200 5,200 125 17 5H:1V 2 97,000 49,000 146,000 35 9 217+200 222+000 4,800 125 17 2H:1V 2 49,000 38,000 87,000 36

10,000 146,000 87,000 233,000

69,226 786,000 353,000 1,139,000

APPENDIX 1

CHANNEL DIMENSIONS QUANTITIES

Placement Area

Distribution Section

No.

From

Station To

Station

Length of Station (Feet)

Width Project Depth

Allowable Overdepth

Includes anticipated shoaling.

Channel end slope is the same as the side slope at the end stations, as shown.

Bolivar Flare - Schedule No. 1

TOTAL OPTION NO. 3

TOTAL SCHEDULE 1

Rollover Pass to Bolivar Flare - Option No. 1

TOTAL OPTION NO. 1

TOTAL, SCHEDULE NO. 1, OPTION

NO. 1, OPTION NO. 2, OPTION NO.

3/4

High Island to Rollover Pass Schedule No. 1

SUBTOTAL, SCHEDULE NO. 1

The term “Required Depth” is synonymous with the term “Prescribed Depth” and “Required Dredging Prism” used elsewhere in the specifications.

SUBTOTAL, SCHEDULE NO. 1

North Ferry Channel - Option No. 2

TOTAL OPTION NO. 2

Rollover Pass - Option No. 3

Rollover Pass - Option No. 4

TOTAL OPTION NO. 4

Amend-0002-W9126G17B0023
Amend 0002 page-2
QST 35 20 23.16 451 APPENDIX 1
Full Template

File details come from the government source that posted it. Updated .