W9126G-16-B-0029-Plans.pdf

PDF 2 MB Posted

Attached to
Houston Ship Channel, Spilman Island Placement Area Dewatering in Harris County, Texas
Solicitation number
W9126G-16-B-0029
Issued by

About this file

Plans for Houston Ship Channel Spilman PA Dewatering.

View the file

Other files

File Type Posted
W9126G-16-B-0029-Specs.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET

# of 6

DWG.

NO. TITLE

1 COVER SHEET

GENERAL

2 G-01 LOCATION PLAN AND INDEX OF DRAWINGS

3 G-02 GENERAL NOTES AND LEGEND

CIVIL-SITE

4 C-01 PLAN - SPILMAN ISLAND PLACEMENT AREA - EXISTING SPOT ELEVATIONS

5 C-02 PLAN - SPILMAN ISLAND PLACEMENT AREA - DEWATERING PLAN

6 C-03 DETAILS - SPILMAN ISLAND PLACEMENT AREA - TYPICAL SECTIONS & DETAILS

6 6 -- Total Number of Drawings

INDEX OF DRAWINGS

NO. CHANNEL

STATION SIZE & CONTENTS OPERATOR T4-NO. PERMIT NO.

MARATHONE

PIPELINE LLC

EQUISTAR

CHEMICAL LP

HOUSTON LIGHTING

& POWER CO.

HOUSTON LIGHTING

& POWER CO.

(1)-6" PETROLEUM MOBILE DA 1999-01585

(1)-8" PETROLEUM PIPELINE CO. D10749

(1)-8" HYDROGEN

(1)-8" CARBON MONOXIDE

(1)-10" SPARE

7 - (2)-4" HYDROGEN AIR PRODUCTS LLC 05828 -

(1)-4" AMMONIA ANHYDROUS WILLIAMS PURITY

(1)-18" ANHYDROUS HYDROGEN CHLORIDE PIPELINES LLC

PIPELINE DATA

HSC-STA. 49+76

345kv AERIAL TRANSMISSION LINE

HSC-STA. 51+376

00884 -

AIR PRODUCTS LLC

07845 12780

- 8132

- 7952

1 HSC-STA. 36+49 (1)-8" BUTANE

(1)-6" PROPYLENE

4 HSC-STA. 40+66

HSC-STA. 39+843

138kv AERIAL TRANSMISSION LINE

2 HSC-STA. 37+65

06412 -

06453 -HSC-STA. 51+96

NAME PID x=Easting y=Northing ELEV

(NAVD88)

0613 J 2004

TCOON

(Morgans Point)

DO9986 3,243,143.03 13,817,079.11 17.4'

HGCSD 43 1986 AW5662 3,242,664.20 13,828,932.43 10.9'

HORIZONTAL AND VERTICAL CONTROL

MONUMENTS

NOTE:

HORIZONTAL COORDINATES ARE REFERENCED TO THE TEXAS STATE

PLANE COORDINATE SYSTEM, SOUTH CENTRAL ZONE, NAD 83.

VERTICAL REFERENCE TO NAVD88 (GEOID 12B).

No. Length (ft)

No. Length (ft)

No. Length (ft)

L1 371 L15 1,307 P1 6,808 L2 425 L16 574 P2 3,462 L3 678 L17 8,785 P3 2,864 L4 898 L18 2,459 P4 1,701 L5 1,225 L19 2,017 P5 3,219 L6 1,464 L20 1,748 P6 1,620 L7 1,844 L21 1,603 P7 2,820 L8 2,250 L22 1,773 P8 3,936 L9 2,163 L23 3,332

L10 2,096 L24 1,475 L11 1,935 L25 2,437 L12 1,488 L26 2,509 L13 1,057 L14 5,812

Spilman Island Placement Area Lateral Ditch Length Perimeter Length

Total Perimeter Length Total Lateral Length 53,727 (ft)

26,430 (ft)

W9126G-16-B-0029-PLANS
GENERAL
2 G-01 LOCATION PLAN AND INDEX OF DRAWINGS
3 G-02 GENERAL NOTES AND LEGEND
CIVIL-SITE
4 C-01 PLAN - SPILMAN ISLAND PLACEMENT AREA - EXISTING SPOT ELEVATIONS
5 C-02 PLAN - SPILMAN ISLAND PLACEMENT AREA - DEWATERING PLAN
6 C-03 DETAILS - SPILMAN ISLAND PLACEMENT AREA - TYPICAL SECTIONS & DETAILS

File details come from the government source that posted it. Updated .