FOR CONSTRUCTION 6-28-2018

DRAWING NUMBER

OFFICE OF THE ENGINEER

DESIGN BY: DATE

DRAWN BY:

FORT STEWART, GEORGIA

SHEET

LCM

LEWIS MILES

DATE DESCRIPTION BY

GEORGIA

SCALE: AS SHOWN

REVISION

OF

MAY 18

3A-1 FS-3960

LIBERTY COUNTY

FT. STEWART

WORK ORDER # K18-11-7J

REPAIR ROOF, BLDG 9592

S L

O P

E

:1

S

L O

P E

:1

ROOF

VENT THROUGH

BOILER STACK

WATER HEATER STACK

AIR DOME

EXHAUST FAN

AIR DOME

EXHAUST FAN

ROOF

VENT THROUGH

COLOR SHALL MATCH EXISTING

METAL ROOF TO BE COATED

EXISTINGNEW

LEGEND

DESCRIPTION

TO BE COATED

MATERIAL OR STRUCTURE

BOOT SEAL

NEOPRENE PIPE

REMOVE AND REPLACE

REMOVE AND REPLACE SEALANT

EXISTING PLUMBING VENT

EXHAUST FAN AIR DOME DETAIL

NOT TO SCALE

BOILER STACK DETAIL

NOT TO SCALE

VENT THROUGH ROOF DETAIL

NOT TO SCALE

BE COATED

METAL FLASHING TO

BE COATED

METAL BATTEN TO

BE COATED

METAL FLASHING TO

BE COATED

METAL BATTEN TO

204'-0"

A-1

B

A-2

A-1

A

A-2

SCALE: „"=1'-0"

ROOF PLAN

A-2

D

A-1

A-1

C

A-2

N

ROOF PLAN

COLOR OF COATING TO BE BERRIDGE COLONIAL RED.7.

ROOF SURFACE AND GUTTERS.

APPLY FLEXIBLE ACRYLIC WATERPROOFING SYSTEM OVER ENTIRE6.

ROOF COATING.

PRESSURE WASH METAL ROOF AND GUTTERS TO PREPARE FOR 5.

THIS SHEET.

REPLACE FLASHING ON VENT THROUGH ROOF PIPES, SEE DETAIL 4.

REPLACE FLASHING ON ROOF CURBS.3.

WASHERS, SEE BID ITEM.

AND NEOPRENE REMOVE AND REPLACE WORN OUT SCREWS2.

REPAIR HOLES IN ROOF SURFACE, SEE BID ITEM.1.

NOTES:

DRAWING NUMBER

OFFICE OF THE ENGINEER

DESIGN BY: DATE

DRAWN BY:

FORT STEWART, GEORGIA

SHEET

LCM

LEWIS MILES

DATE DESCRIPTION BY

GEORGIA

SCALE: AS SHOWN

REVISION

OF

MAY 18

3A-2 FS-3960

LIBERTY COUNTY

FT. STEWART

WORK ORDER # K18-11-7J

REPAIR ROOF, BLDG 9592

A-1

A

A-2

ELEVATION

SCALE: „"=1'-0"

ELEVATION

SCALE: „"=1'-0"A-1

B

A-2

ELEVATION

SCALE: „"=1'-0"A-1

D

A-2

ELEVATION

SCALE: „"=1'-0"A-1

C

A-2

METAL ROOF TO BE COATED

METAL ROOF TO BE COATED

METAL ROOF TO BE COATED

METAL ROOF TO BE COATED

ELEVATIONS

FS3960-01
FS3960-02
FS3960-03