This document is an Industry Questions document for Solicitation W9124L25QA006 concerning Concrete Barriers. The solicitation is a Total Small Business Set-Aside for concrete barriers with several key specifications: barriers can be new or used, must include rebar reinforcement (though no specific requirements are specified), and will be delivered unpainted with no identification markings. Delivery will be to a fenced area behind Building H1515, requiring prior scheduling and base access credentials.

The government has specified minimal technical requirements for the barriers, including no mandated compressive strength or mix design requirements. Contractors are required to complete blocks 30a, 30b, 30c, and the unit price/amount section of the SF1449 form. Barriers will be inspected only for dimensions and appearance upon delivery, and no special certifications, plant qualifications, or additional insurance beyond standard liability are required. The procurement allows flexibility for vendors while maintaining basic performance expectations for the concrete barriers.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Industry Questions

W9124L25QA006 – Concrete Barriers

1. The RFQ itself does not specify if this is only set aside for WOSB. Could you clarify?

Government Response: Total Small Business Set-Aside

2. Are barriers required to include rebar reinforcement? If so, please specify size, grade, placement, and lap requirements.

Government Response: Yes. No specific size, grade, placement, and lap requirements.

3. Do the Barriers have to be brand new or used?

Government Response: Either

4. What minimum compressive strength (psi) and mix design requirements apply (e.g., 28-day strength, air entrainment, admixtures)?

Government Response: No required compressive strength or mix design requirements apply

5. Will barriers be inspected on delivery for dimensions and appearance only, or are strength test reports required at the time of delivery?

Government Response: Yes, just inspected on delivery for dimensions and appearance only

6. The salient characteristics list the fenced area behind Bldg. H1515 as the drop-oƯ point. Please confirm if any prior scheduling, base access credentials, or escort requirements will be needed for delivery.

Government Response: Yes, scheduling and base passes are all necessary

7. Please confirm that barriers are to be delivered unpainted and whether any stenciling or identification markings are required.

Government Response: Unpainted and no stenciling or identification is required

8. Does the contractor fill out the SF1449?

Government Response: Yes – blocks 30a., 30b., 30c and the unit price/amount section on page 3.

9. Are there any special certifications, plant qualifications, or insurance requirements (beyond standard liability/auto/workers’ comp) for manufacturing and delivering these barriers?

Government Response: No