Technical_Exhibit_7.5.9.7_Fuel_Oil_Tanks_At_Dual_Fired_Facilities.doc

DOC document 60 KB Posted

Attached to
FORT GORDON BASE OPERATIONS AND MAINTENANCE SUPPORT SERVICES REQUEST FOR PROPOSAL - SOLICITATION Federal contract opportunity
Solicitation number
W91249-18-R-0001
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Gordon

About this file

Attachment 6 - TE 7.5.9.7 - Fuel Oil Tanks at Dual Fired Facilities

View the file

Other files for this federal contract opportunity

Other files attached to FORT GORDON BASE OPERATIONS AND MAINTENANCE SUPPORT SERVICES REQUEST FOR PROPOSAL - SOLICITATION, newest first.
File Type Posted
Attachment_10_-_Pricing_and_Labor_Matrix_Worksheet_(Revision_2).xlsx XLSX spreadsheet
CONFORMED_COPY_W91249-18-R-0001.docx DOCX document
W91249-18-R-0001-0004.docx DOCX document
Attachment_16_-_Revised_Questions_&_Responses_to_Solicitation_&_Amendment_0001_0002__and_0003.pdf PDF
Technical_Exhibit_7.5.9.8.1__Dumpster_Locations_List.docx DOCX document
W91249-18-R-0001-0002.docx DOCX document
Attachment_1_-_Performance_Work_Statement.docx DOCX document
Technical_Exhibit_7.5.7.2_Grounds_Sections.doc DOC document
Technical_Exhibit_7.4.4__Training_and_Medical_Testing.docx DOCX document
Technical_Exhibit_7.5.9.4__Central_Energy_Plant_No._2_Bldg_310_Installed_Equipment.doc DOC document
Attachment_15_-_Site_Visit_-_Access_Control_Information.pdf PDF
Attachment_2_-_Technical_Exhibit_1_-_7.1_Performance_Requirements_Summary.docx DOCX document
Technical_Exhibit_7.5.6.10__Installation_Irrigation_Systems.docx DOCX document
Technical_Exhibit_7.5.7.10_Line_Clearing_Specifications.docx DOCX document
Technical_Exhibit_7.5.8.6._Dams.docx DOCX document
Technical_Exhibit_7.5.6.4__Wastewater_Lines_of_Demarcation.doc DOC document
Technical_Exhibit_7.5.9.6__Bureau_of_Mine_Standards_for_Water_Treatment.doc DOC document
Technical_Exhibit_7.5.6.13_Communcation_Towers.docx DOCX document
Attachment_13_-_Specific_Relevant_Contract_Reference_Sheet.docx DOCX document
Attachment_14_-_Questions_and_Responses_to_DRAFT_Solicitation.pdf PDF
Technical_Exhibit_7.5.6.5_Water_Lines_of_Demarcation.doc DOC document
Technical_Exhibit_7.5.5.3_Estimated_Annual_Pesticide_Usage.docx DOCX document
Technical_Exhibit_7.5.6.1_Preventive_Maintenance_Equipment.docx DOCX document
Technical_Exhibit_7.3.6__Estimated_U-Do-It_Training_Workload.docx DOCX document
Technical_Exhibit_7.5.6.15_Playground_Equipment.docx DOCX document
Technical_Exhibit_7.5.6.17_DMO_Barracks_Report_Template.doc DOC document
Attachment_12_-_Sample_Past_Performance_Evaluation_Questionnaire_Form.docx DOCX document
Technical_Exhibit_7.5.4.1_Visible_Emission_Form.docx DOCX document
Attachment_3_-_Technical_Exhibit__2_-_7.2__Deliverables.docx DOCX document
Technical_Exhibit_7.5.6.16_Facilities_M&R_Services_Performance_Metrics_Template.doc DOC document
Technical_Exhibit_7.5.6.11_UMCS_Demarcation_List.docx DOCX document
Technical_Exhibit_7.5.6.6_Range_Hood_Cleaning_Services.docx DOCX document
Technical_Exhibit_7.5.7.5_Range_Mowing_Map.docx DOCX document
Technical_Exhibit_7.5.9.2__Central_Energy_Plant_No._1_Building_25910_Buildings_Served.docx DOCX document
Technical_Exhibit_7.5.7.7_Flower_Beds.doc DOC document
Attachment_11_-_Sample_Past_Performance_Cover_Letter.docx DOCX document
Technical_Exhibit_7.5.4.3_Underground_Storage_Tanks.docx DOCX document
Technical_Exhibit_7.4.5__Government_Furnished_Vehicles.docx DOCX document
Technical_Exhibit_7.4.3__Fort_Gordon_Facility_Listing_(Excluding_Privatized_Facilities).docx DOCX document
Technical_Exhibit_7.5.8.5_Lakes_and_Ponds.docx DOCX document
Technical_Exhibit_7.5.6.2_Electrical_Lines_of_Demarcation.doc DOC document
Attachment_8_-_Service_Contract_Act_(SCA)_Wage_Determation_2015-4465_Rev5.pdf PDF
Technical_Exhibit_7.5.9.8_Dumpster_Container_Cleaning_List.docx DOCX document
Technical_Exhibit_7.5.6.3__Natural_Gas_Lines_of_Demarcation.doc DOC document
Technical_Exhibit_7.5.9.3a__Plant_No._1_Operation_CEP_CHW_and_High_Temperature_Water_(HTW).doc DOC document
Technical_Exhibit_7.4.7_Energy_Conservation_Measures.docx DOCX document
W91249-18-R-0001.pdf PDF
Technical_Exhibit_7.4.1__Contractor_Personnel_Minimum_Qualifications.docx DOCX document
Technical_Exhibit_7.5.7.6_Semi-Improved_Grounds_Maintenance_Areas_Frequency_Schedule.docx DOCX document
Technical_Exhibit_7.5.6.20_Pest_Control_Services_Look_Ahead_Report_Template.doc DOC document
Show all 50

FORT GORDON BASE OPERATIONS AND MAINTENANCE SUPPORT SERVICES REQUEST FOR PROPOSAL - SOLICITATION has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Technical Exhibit 7.5.9.7 Fuel Oil Tanks At Dual Fired Facilities

Locations

Date: 2/22/13

Building/Facility Name/Use Fill Table Capacity 90% Capacity (Gallons) 90% Capacity (Inches) Measurement (Inches) Amount of Fuel From Table Amount of Fuel Required Inches of Water Notes

250 Griffith Hall 2 8,000 7200 98 Above ground tank

322 Dental Lab 1 10,000 9000 81 Below ground tank (Read 2/15/13)

14600 DPW/Maint 1 8,000 7200 80 Underground tank

14603 DPW/Maint 3 15,000 13500 101 Above ground tank

21610 Theater 2 8,000 7200 98 Above ground tank

25501 Dental Clinic 1 5,000 4500 79 Underground tank

32100 Dinner Theater 2 8,000 7200 98 Above ground tank

33500 Library 2 8,000 7200 98 Above ground tank

35200 (North) Pxtra 1 8,000 7200 80 Underground tank closest to equipment room

35200 (South) Pxtra 1 10,000 9000 81 Underground tank furthest from equipment room

36700 (North) Ring Hall 1 8,000 7200 80 Underground tank near equipment room

36700 (South) Ring Hall 1 8,000 7200 80 Underground tank near chiller

Total: 0

&16Attachment J- C5.9 07 Fuel Oil Tanks At Dual Fired Facilities

FOUO - Source Selection Sensitive - See FAR 2.101 and FAS 3.104

FILL TABLE 1 UNDERGROUND

BURNER FUEL #2 FILL CHART

(BLDG 322, 14600, 25501, 35200, 36700)

Bldg,Tank 25501 35200 (N) 322

36700 (N&S) 35200 (S)

14600

Cap.(gal) 5,000 8,000 10,000

Dimension 8' x 13' 6" 8' x 21' 4" 8' x 26' 8"

(inches) (gal) (gal) (gal)

1 , 49 9 , 2606 14 , 4118 18 , 5147

2 , 50 26 , 2673 41 , 4224 51 , 5280

3 , 51 47 , 2740 75 , 4330 93 , 5413

4 , 52 72 , 2808 114 , 4436 143 , 5546

5 , 53 101 , 2875 159 , 4542 199 , 5678

6 , 54 132 , 2942 209 , 4648 261 , 5810

7 , 55 166 , 3008 262 , 4753 328 , 5942

8 , 56 202 , 3075 319 , 4858 399 , 6073

9 , 57 240 , 3141 380 , 4963 475 , 6204

10 , 58 281 , 3207 443 , 5067 554 , 6335

11 , 59 323 , 3273 510 , 5171 637 , 6464

12 , 60 366 , 3338 579 , 5274 723 , 6594

13 , 61 412 , 3403 650 , 5377 813 , 6722

14 , 62 458 , 3468 724 , 5479 905 , 6850

15 , 63 507 , 3532 800 , 5581 1001 , 6976

16 , 64 556 , 3596 879 , 5681 1098 , 7102

17 , 65 607 , 3659 959 , 5781 1199 , 7227

18 , 66 659 , 3722 1041 , 5880 1301 , 7351

19 , 67 712 , 3784 1125 , 5979 1406 , 7474

20 , 68 766 , 3845 1211 , 6076 1513 , 7595

21 , 69 821 , 3906 1298 , 6172 1622 , 7715

22 , 70 878 , 3966 1387 , 6267 1733 , 7834

23 , 71 935 , 4026 1477 , 6361 1846 , 7952

24 , 72 993 , 4085 1508 , 6454 1960 , 8068

25 , 73 1051 , 4142 1661 , 6545 2076 , 8182

26 , 74 1111 , 4200 1755 , 6635 2194 , 8295

27 , 75 1171 , 4256 1850 , 6724 2313 , 8406

28 , 76 1232 , 4311 1946 , 6811 2433 , 8515

29 , 77 1293 , 4365 2043 , 6897 2554 , 8622

30 , 78 1356 , 4418 2142 , 6981 2677 , 8727

31 , 79 1418 , 4470 2241 , 7063 2801 , 8829

32 , 80 1481 , 4521 2341 , 7143 2926 , 8930

33 , 81 1545 , 4571 2441 , 7222 3052 , 9027

34 , 82 1609 , 4619 2543 , 7298 3178 , 9123

35 , 83 1674 , 4666 2645 , 7372 3306 , 9215

36 , 84 1739 , 4711 2748 , 7443 3434 , 9305

37 , 85 1804 , 4755 2851 , 7512 3564 , 9391

38 , 86 1870 , 4797 2955 , 7579 3693 , 9474

39 , 87 1936 , 4837 3059 , 7642 3824 , 9553

40 , 88 2002 , 4875 3164 , 7703 3955 , 9629

41 , 89 2069 , 4911 3269 , 7760 4086 , 9700

42 , 90 2136 , 4945 3374 , 7813 4218 , 9767

43 , 91 2203 , 4976 3480 , 7863 4350 , 9829

44 , 92 2270 , 5005 3586 , 7908 4482 , 9885

45 , 93 2337 , 5030 3692 , 7947 4615 , 9935

46 , 94 2404 , 5051 3798 , 7981 4748 , 9977

47 , 95 2471 , 5068 3904 , 8008 4881 ,10010

48 , 96 2539 , 5077 4011 , 8022 5014 ,10027

Attachment J- C5.9 08 Fuel Oil Tanks At Dual Fired Facilities

FOUO - Source Selection Sensitive - See FAR 2.101 and FAS 3.104

FILL TABLE 2 ABOVE GROUND 8K

BURNER FUEL # 2 FILL CHART

8,000 Gallon Tank (Bldg 250, 21610,32100, 33500) inches gals inches gals inches gals inches gals inches gals

0.5 7 23 1,119 45.5 2,881 68 4,830 90.5 6,674

1 15 23.5 1,154 46 2,923 68.5 4,874 91 6,711

1.5 25 24 1,189 46.5 2,966 69 4,917 91.5 6,748

2 36 24.5 1,224 47 3,008 69.5 4,960 92 6,785

2.5 48 25 1,259 47.5 3,051 70 5,003 92.5 6,822

3 62 25.5 1,295 48 3,094 70.5 5,046 93 6,858

3.5 76 26 1,331 48.5 3,137 71 5,089 93.5 6,894

4 92 26.5 1,367 49 3,179 71.5 5,131 94 6,930

4.5 109 27 1,403 49.5 3,222 72 5,174 94.5 6,966

5 126 27.5 1,440 50 3,265 72.5 5,217 95 7,001

5.5 144 28 1,477 50.5 3,309 73 5,259 95.5 7,037

6 163 28.5 1,514 51 3,352 73.5 5,302 96 7,072

6.5 183 29 1,552 51.5 3,395 74 5,344 96.5 7,106

7 204 29.5 1,589 52 3,438 74.5 5,387 97 7,141

7.5 225 30 1,627 52.5 3,481 75 5,429 97.5 7,175

8 246 30.5 1,665 53 3,525 75.5 5,471 98 7,208

8.5 267 31 1,703 53.5 3,568 76 5,513 98.5 7,242

9 292 31.5 1,742 54 3,612 76.5 5,555 99 7,275

9.5 315 32 1,780 54.5 3,655 77 5,597 99.5 7,308

10 339 32.5 1,819 55 3,698 77.5 5,639 100 7,340

10.5 364 33 1,858 55.5 3,742 78 5,680 100.5 7,373

11 389 33.5 1,897 56 3,786 78.5 5,722 101 7,404

11.5 415 34 1,936 56.5 3,829 79 5,763 101.5 7,436

12 441 34.5 1,976 57 3,873 79.5 5,805 102 7,461

12.5 468 35 2,016 57.5 3,916 80 5,846 102.5 7,498

13 495 35.5 2,055 58 3,960 80.5 5,887 103 7,528

13.5 523 36 2,095 58.5 4,003 81 5,928 103.5 7,558

14 551 36.5 2,135 59 4,047 81.5 5,968 104 7,588

14.5 579 37 2,176 59.5 4,091 82 6,009 104.5 7,617

15 608 37.5 2,216 60 4,134 82.5 6,049 105 7,646

15.5 637 38 2,257 60.5 4,178 83 6,090 105.5 7,675

16 667 38.5 2,298 61 4,222 83.5 6,130 106 7,703

16.5 697 39 2,338 61.5 4,265 84 6,170 106.5 7,730

17 727 39.5 2,379 62 4,309 84.5 6,210 107 7,757

17.5 758 40 2,421 62.5 4,352 85 6,249 107.5 7,784

18 789 40.5 2,462 63 4,396 85.5 6,289 108 7,810

18.5 821 41 2,503 63.5 4,440 86 6,328 108.5 7,836

19 853 41.5 2,545 64 4,483 86.5 6,367 109 7,861

19.5 885 42 2,586 64.5 4,527 87 6,406 109.5 7,886

20 917 42.5 2,628 65 4,570 87.5 6,445 110 7,910

20.5 950 43 2,670 65.5 4,614 88 6,484 110.5 7,933

21 983 43.5 2,712 66 4,657 88.5 6,522 111 7,956

21.5 1,017 44 2,754 66.5 4,700 89 6,560 111.5 7,979

22 1,051 44.5 2,796 67 4,744 89.5 6,598 112 8,001

22.5 1,085 45 2,838 67.5 4,787 90 6,636 112.5 8,022

Attachment J- C5.9 08 Fuel Oil Tanks At Dual Fired Facilities

FOUO - Source Selection Sensitive - See FAR 2.101 and FAS 3.104

FILL TABLE 3 ABOVE GROUND 15K

BURNER FUEL #2 FILL CHART

15,000 Gallon Tank, (Bldg 14603)

(inches) (gals) (inches) (gals) (inches) (gals) (inches) (gals) (inches) (gals) (inches) (gals)

0.5 7 20.5 1,706 40.5 4,461 60.5 7,595 80.5 10,719 100.5 13,442

1.0 19 21 1,767 41 4,536 61 7,674 81 10,794 101 13,501

1.5 36 21.5 1,827 41.5 4,612 61.5 7,754 81.5 10,869 101.5 13,559

2.0 55 22 1,889 42 4,688 62 7,834 82 10,943 102 13,616

2.5 76 22.5 1,951 42.5 4,764 62.5 7,913 82.5 11,017 102.5 13,673

3 100 23 2,013 43 4,841 63 7,993 83 11,091 103 13,729

3.5 126 23.5 2,076 43.5 4,917 63.5 8,073 83.5 11,164 103.5 13,784

4 154 24 2,140 44 4,994 64 8,152 84 11,237 104 13,838

4.5 183 24.5 2,204 44.5 5,071 64.5 8,232 84.5 11,310 104.5 13,892

5 214 25 2,268 45 5,148 65 8,311 85 11,383 105 13,945

5.5 247 25.5 2,333 45.5 5,225 65.5 8,391 85.5 11,455 105.5 13,998

6 281 26 2,399 46 5,303 66 8,470 86 11,527 106 14,049

6.5 316 26.5 2,465 46.5 5,380 66.5 8,549 86.5 11,599 106.5 14,100

7 353 27 2,531 47 5,458 67 8,629 87 11,670 107 14,150

7.5 391 27.5 2,598 47.5 5,536 67.5 8,708 87.5 11,741 107.5 14,199

8 430 28 2,665 48 5,614 68 8,787 88 11,812 108 14,247

8.5 471 28.5 2,733 48.5 5,692 68.5 8,866 88.5 11,882 108.5 14,295

9 512 29 2,801 49 5,771 69 8,945 89 11,952 109 14,341

9.5 555 29.5 2,869 49.5 5,849 69.5 9,023 89.5 12,022 109.5 14,387

10 598 30 2,938 50 5,928 70 9,102 90 12,091 110 14,431

10.5 643 30.5 3,008 50.5 6,006 70.5 9,181 90.5 12,160 110.5 14,475

11 688 31 3,077 51 6,085 71 9,259 91 12,229 111 14,518

11.5 735 31.5 3,147 51.5 6,164 71.5 9,337 91.5 12,297 111.5 14,559

12 782 32 3,218 52 6,243 72 9,416 92 12,364 112 14,599

12.5 830 32.5 3,288 52.5 6,322 72.5 9,494 92.5 12,432 112.5 14,639

13 880 33 3,359 53 6,401 73 9,572 93 12,498 113 14,677

13.5 930 33.5 3,431 53.5 6,480 73.5 9,649 93.5 12,565 113.5 14,713

14 980 34 3,502 54 6,560 74 9,727 94 12,631 114 14,749

14.5 1,032 34.5 3,574 54.5 6,639 74.5 9,804 94.5 12,696 114.5 14,783

15 1,084 35 3,647 55 6,718 75 9,882 95 12,761 115 14,815

15.5 1,137 35.5 3,719 55.5 6,798 75.5 9,959 95.5 12,826 115.5 14,846

16 1,191 36 3,792 56 6,877 76 1,036 96 12,890 116 14,876

16.5 1,246 36.5 3,865 56.5 6,957 76.5 10,113 96.5 12,953 116.5 14,904

17 1,301 37 3,939 57 7,037 77 10,189 97 13,016 117 14,930

17.5 1,357 37.5 4,013 57.5 7,116 77.5 10,265 97.5 13,079 117.5 14,953

18 1,414 38 4,087 58 7,196 78 10,342 98 13,141 118 14,975

18.5 1,471 38.5 4,161 58.5 7,276 78.5 10,418 98.5 13,202 118.5 14,994

19 1,529 39 4,236 59 7,355 79 10,493 99 13,263 119 15,010

19.5 1,587 39.5 4,310 59.5 7,435 79.5 10,569 99.5 13,323 119.5 15,023

20 1,647 40 4,386 60 7,515 80 10,644 100 13,383 120 15,030

Attachment J- C5.9 08 Fuel Oil Tanks At Dual Fired Facilities

FOUO - Source Selection Sensitive - See FAR 2.101 and FAS 3.104