Item # Description Material
Type Order Unit
1 Metal Wall Panels-26gs .36" exposure (Roof Color) Metal 281 SF
2 J Channel for Metal Wall Panels (Roof Color) Metal 210 LF
3 Metal Soffit Panels 1'-6' Wide (Roof Color) Metal 170 LF
4 24 in. x 50 ft. Dark Red Aluminum Trim Coil (Match Roof Color) Metal 3 RL
5 Alum Gutters 4" Square Style (Roof Color) Metal 86 LF
6 Alum 6" Downspouts (Red) Metal 2 EA
7 Alum Vents/Screen 14"x 24" (50% clear Area) (Roof Color) Metal 2 EA
B
A-203
ELEVATION VALUE
REFERENCE
DESCRIPTION
DETAIL NO.
NORTH ARROW
DEMO MARK
DRAWING NO.
SHEET NO.
1 View Name 1/8" = 1'-0"A1-01
15' - 4"
AFF
A 11'-0"
SHEET NUMBERING LEGEND
DISCIPLINE
G GENERAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
Q EQUIPMENT
P PLUMBING
M MECHANICAL
E ELECTRIAL
X MISCELLANEOUS
PAGE NUMBERSECTION
0 DEMOLITION / GENERAL
1 PLANS
2 EXTERIOR ELEVATIONS
3 BUILDING / WALL SECTIONS
4 ELARGED PLANS &
RELATED DETAILS
5 DETAILS & SCHEDULE
6 FINISH PLAN & SCHEDULES
7 INTERIOR ELEVATIONS
8 BID ALTERNATES (LARGE)
9 RESERVED
A1-01
SYMBOL LEGEND
W1
1i
1i
1i
SCALE
DRAWING NAME
SHEET NO.
SECTION MARK
A-203
SHEET NO.
DETAIL NO.
ACTUAL NUMBER OF
PEOPLE
MAX. EGRESS
CAPACITY
A-203
A-203 CALLOUT DETAIL
SHEET NO.
DETAIL NO.
EXTERIOR ELEVATION
MARK
INTERIOR ELEVATION
MARK
SHEET NO.
DETAIL NO.
EGRESS CALCULATION
MARK
Room name
101A ROOM NAME/NUMBER
CONTROL / ELEVATION
MARK
DOOR MARK
WINDOW MARK
CASEWORK MARK
EQUIPMENT MARK
REVISION AREA / NUMBER
CEILING TYPE / HEIGHT
WALL MARK
ACCESSORIES MARK
@ AT
AB AREA DRAIN
ACC ACCENT COLOR
ACT ACOUSTICAL CEILING TILE
ACOUS ACOUSTIC
ACW ACOUSTICAL WALL PANELS
ADJ ADJUSTABLE
AE APPROVED EQUAL
AFF ABOVE FINISH FLOOR
AFL ATHLETIC FLOORING
AHU AIR HANDLING UNIT
ALB ALUMINUM BASE
ALT ALUMINUM TILE
ALUM ALUMINUM
ANOD ANODIZED
ANSI AMERICAN NATIONAL
STANDARDS INSTITUTE
ATTEN ATTENUATION
AWP ACRYLIC WALL PANELS
BBT BIOBASED TILE
BF BLOCK FILL
BFC BROOMED FINISHED
CONCRETE
BL BLINDS
BLDG BUILDING
BLKG BLOCKING
BOT BOTTOM
BFG BULLET PROOF GLASS
CB# CATCH BASIN
CEM CEMENTIOUS SIDING
CF CORK FLOORING
CFCI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CFT CERAMIC FLOOR TILE
CG CURVED CEILING GRID
CI CAST IRON
CI# CURB INLET
CJ CONTROL JOINT
CLG CEILING
CL CENTERLINE
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONSTR CONSTRUCTION
CONTR CONTRACTOR
CORR CORRUGATED
CPT CARPET
CPTT CARPET TILE
CTB CERAMIC TILE BASE
CRC COLD ROLLED CHANNEL
CRF CORK RUBBER FLOORING
CS COUNTERSUNK
CWT CERAMIC WALL TILE
DET DETAIL
DEPT DRY FOG PAINT
DIA DIAMETER
DISP DISPENSER
DN DOWN
DP DEEP
DR DOOR
DS DOWNSPOUT
E/W EACH WAY
EDG EDGE BANDING
EES EMERGENCY EYE WASH
AND SHOWER
EFC EPOXY FLOOR COATING
EIFS EXTERIOR INSULATION
FINISH SYSTEM
EIP EXISTING IRON PIPE
ELEV ELEVATION
EJ EXPANSION JOINT
EN ENAMEL
EPT HIGH PERFORMANCE
EPOXY PAINT
EQ EQUAL
EST EXISTING
EXT EXTERIOR
EXP EXPOSED CEILING
EWC ELECTRIC WATER
COOLER
FC FIRECODE
FD FLOOR DRAIN
FEB FIRE EXSTINGUISHER
BRACKET
FEC FIRE EXSTINGUISHER
CABINET
FF FINISH FLOOR
FH FIRE HYDRANT
FLU FLOURESCENT
FOF FACE OF FRAME
FOM FACE OF MASONRY
FTG FOOTING
GC GENERAL CONTRACTOR
GCT GRANITE COUNTERTOP
GA GAGE
GALV GALVANIZED
GEN GENERATOR
GFT GRANITE FLOOR TILE
GL GLASS
GMT GLASS MOSAIC TILE
GT GROUT
GYP GYPSUM BOARD
HC HOLLOW CORE
HB HOSE BIB
HC HANDICAPP
HDWD HARDWOOD
HM HOLLOW METAL
HORZ HORIZONTAL
HR HOUR
ICF INFECTION CONTROL
FLOORING
ID INSIDE DIAMETER
INSTAL INSTALLATION
INSUL INSULATION
INT INTERIOR
INV INVERT
JB JOIST BEARING
JB# JUNCTION BOX
JT JOINT
L LONG
LFT LINOLEUM FLOOR TILE
LP LIGHT POLE
LST LINOLEUM SHEET
FLOORING
LVT LUXURY VINYL TILE
MATL MATERIAL
MAX MAXIMUM
MC METAL CANOPY
MCT METAL CEILING TILE
MB MASONRY - BRICK
MECH MECHANICAL
MFR MANUFACTURER
MFT MARBLE FLOOR TILE
MIN MINIMUM
MO MASONRY OPENING
MTB MARBLE TILE BASE
MTD MOUNTED
MTL METAL
MWM METAL WALK-OFF MAT
MWT MARBLE WALL TILE
NIC NOT IN CONTRACT
NOM NORMAL
OC ON CENTER
OD OUTSIDE DIAMETER
OFOI OWNER FURNISHED,
OWNER INSTALLED
OFCI OWNER FURNISHED,
CONTRACTOR INSTALLED
OPP OPPOSITE
OZ OUNCE
P-LAM PLASTIC LAMINATE
P-LAM WD PLASTIC LAMINATE
WOOD DOORS
PC POLISHED CONCRETE
PERF PERFORATED
PFT PORCELAIN FLOOR TILE
PIV POST INDICATOR VALVE
PL PLATE
PLYWD PLYWOOD
PNT PAINT
POLYETH POLYETHYLENE
PP POWER POLE
PR PAIR
PTB PORCELAIN TILE BASE
PTD PAINTED
PTP PLASTIC TOILET
PARTITIONS
PWT PORCELAIN WALL TILE
PVC POLYVINYL CHLORIDE
QS QUARTZ SURFACE
QT QUARRY TILE
QZT QUARTZ TILE
R RADIUS
R&S ROD AND SHELF
RB RUBBER BASE
RBT RUBBER TILE
RCP REINFORCED CONCRETE
RD ROOF DRAIN
RDL ROOF DRAIN LEADER
RECEPT RECEPTACLE
RECYF RECYCLED FLOORING
REQD REQUIRED
RES RESILIENT
RM RUBBER MAT
ROW RIGHT OF WAY
RSF RESINOUS FLOORING
RTF RESILENT TILE FLOORING
SAT SPRAYED ACOUSTICAL
TREATMENT
SC SEALED CONCRETE
SCH SCHEDULE
SCW SOLID CORE WOOD
SDT STATIC DISSIPATIVE TILE
SF SQUARE FEET
SHEATH SHEATHING
SIM SIMILAR
SLS SOLID SURFACE
SP SPACES
SQ SQUARE
SS STAINLESS STEEL
SSC STAINED SEALED
CONCRETE
SRT SLIP RESISTANT TILE
ST STEEL
ST&R STAIR TREADS AND
RISERS
STD STANDARD
SUSP SUSPENDED
TC TERRA COTTA
T&G TONGUE AND
GROOVE
TCA TILE COUNCIL OF
AMERICA
TELE TELEPHONE
TEMP TEMPERED
TEXD TEXTURED
TFT TERRAZZO FLOOR
TILE
TOC TOP OF CURB
TOS TOP OF STEEL
TP TELEPHONE POLE
TVB TELEVISION
MOUNTING BRACKET
TYP TYPICAL
UL UNDERWRITERS
LABORATORY
U/L UTILITY/LIGHTS
UON UNLESS OTHERWISE
NOTED
VACT VINYL ACOUSTICAL
TILE
VB VAPOR BARRIER
VCT VINYL COMPOSITION
TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VWC VINYL WALL
COVERING
W/ WITH
WC WATER CLOSET
WD WOOD
WF WOOD FLOORING
WWF WELDED WIRE
FABRIC
WWM WELDED WIRE MESH
ABBREVIATIONS
DRAWN BY:
CHECKED BY:
of
Th is d raw ing an d t he de sig n s ho wn is the pro pe rty of
Sm ith
Si nn ett Ar ch ite ctu re, P.A . t he re pro du ctio n o r u se of th is pro pe rty wi tho ut the wr itte n c on se nt of the
Arc hit ec t is pr oh ibit ed
. A ny in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub jec t to leg al ac tio n.
Al l co pie s o f th is d raw ing mu st b e r etu rne d t o t he
Ar ch ite ct a t th e co mp let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
ING
IS
FO
RM
AT
TE
D T O
BE
PR
INT
ED
O N A
" X
" S
HE
ET
T 9
1 8
F 9
1 3
La ke
B oo ne Tr ail Su ite
Ra lei gh
, N C inf o@ sm ith sin ne tt.c om
DESCRIPTIONDATEID
F:
\2
\2
-D ra w in gs \re vi t\2
N at G ua rd
S to ra ge
L
AR
G E.
rv t
/10
/20
:58
:17 P
M
G0-01
COVER SHEET
KB
2015004 10 OCT 2016
DMM/JRC
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
1 9
NC NATIONAL GUARD STORAGE BLDG
LARGE STORAGE BUILDING
NORTH CAROLINA
NC
N
AT
IO
NA
L
G U A R
D
ST
O R A G
E
BL
D G
LA
RG
E
ST
OR
AG
E
BU
IL
DI
NG
NO
RT
H
CA
RO
LI
NA
REGISTEREDARC
HI
TE
CT
UR
AL
CORPORAT ION
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
INDEX OF DRAWINGS
GENERAL
G0-01 COVER SHEET
G0-02 BUILDING CODE SUMMARY
G0-03 SPECIFICATIONS
G0-04 SPECIFICATIONS
G0-05 SPECIFICATIONS
STRUCTURAL
S1-01 FOUNDATION AND FRAMING PLANS
S2-02 STRUCTURAL NOTES AND DETAILS
ARCHITECTURAL
A1-01 FLOOR PLAN
A2-01 BUILDING ELEVATIONS
A3-01 WALL SECTIONS
A5-01 DOOR SCHEDULE, DOOR ELEVATIONS, DETAILS
ELECTRICAL
E0-01 ELECTRICAL NOTES, LEGENDS OR SPECIFICATIONS
E1-01 ELECTRICAL PLAN
DESIGN PROFESSIONALS
DEPARTMENT OF PUBLIC SAFETY / NORTH CAROLINA NATIONAL GUARD
SCO # 14-11206-01
ARCHITECTURE:
SMITH SINNETT ARCHITECTURE
4600 LAKE BOONE TRAIL, SUITE 205
RALEIGH, NC 27607
919.781.8582 (P)
919.781.3979 (F)
POC: ROBERT CARMAC, AIA
rcarmac@smithsinnett.com
STRUCTURAL:
ROSS LINDEN ENGINEERS PC
710 W. NORTH STREET
RALEIGH, NC 27603
POC: BRIAN ROSS, PE
919.832.5680 (P) brian@rosslinden.com
ELECTRICAL:
ENGINEERED DESIGNS INC.
1151 SOUTHEAST CARY PARKWAY, CARY, NC 27518
POC: TOMAS VELEZ-RIVERA, PE
919.581.8481 (P) tvelez@engineereddesigns.com
OWNER:
NORTH CAROLINA NATIONAL GUARD
1636 GOLD STAR DRIVE
RALEIGH, NC 27607
POC: WILLIAM BURRIOLA
919.664.6354 (P) william.s.buriola.mil@mail.mil
SC
O
4-
6-
A
DECISION MATRIX
BUILDABLE AREAS IN NORTH CAROLINA
NON-BUILDABLE
AREA NON-BUILDABLE
AREA
NON-BUILDABLE
AREA
NON-BUILDABLE
AREA
FINISH OPTION
DOOR LOCATION - FRONT LEFT OF ROLL-UP DOOR RIGHT OF ROLL-UP DOOR
DOOR LOCATION - SIDE LEFT SIDE RIGHT SIDE
DOWNSPOUT LOCATION FRONT BACK
DOWNSPOUT DISCHARGE SPLASH BLOCK METAL DS BOOT W/
CORRUGATED PIPE
METER BASE LOCATION LEFT SIDE RIGHT SIDE
FINISH OPTION
(SEE A1-01)
OPTION 1 OPTION 2 OPTION 3
CHOOSE DESIRED OPTIONS BELOW
of
Th is d raw ing an d t he de sig n s ho wn is the pro pe rty of
Sm ith
Si nn ett Ar ch ite ctu re, P.A . t he re pro du ctio n o r u se of th is pro pe rty wi tho ut the wr itte n c on se nt of the
Arc hit ec t is pr oh ibit ed
. A ny in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub jec t to leg al ac tio n.
Al l co pie s o f th is d raw ing mu st b e r etu rne d t o t he
Ar ch ite ct a t th e co mp let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
ING
IS
FO
RM
AT
TE
D T O
BE
PR
INT
ED
O N A
" X
" S
HE
ET
T 9
1 8
F 9
1 3
La ke
B oo ne Tr ail Su ite
Ra lei gh
, N C inf o@ sm ith sin ne tt.c om
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
F:
\2
\2
-D ra w in gs \re vi t\2
N at G ua rd
S to ra ge
L
AR
G E.
rv t
/10
/20
:23
:20 P
M
G0-02
BUILDING CODE
SUMMARY
2015004 10 OCT 2016
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
2 9
KDB
DMM/JRC
NC
N
A T
IO
NA
L
G U A R
D
ST
O R A G
E
BL
D G
LA
RG
E
ST
OR
AG
E
BU
IL
DI
NG
NO
RT
H
CA
RO
LI
NA
REGISTEREDARC
HI
TE
CT
UR
AL
CORPORAT ION
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
2012 APPENDIX B
BUILDING CODE SUMMARY
FOR ALL COMMERCIAL PROJECTS
NAME OF PROJECT:
ADDRESS:
OWNER / AUTHORIZED AGENT:
OWNED BY:
CODE ENFORCEMENT JURISDICTION: CITY
CITY/COUNTY
COUNTY
PRIVATE
STATE
STATE
LEAD DESIGN PROFESSIONAL:
ARCHITECTURAL
CIVIL
ELECTRICAL
FIRE ALARM
PLUMBING
MECHANICAL
SPRINKLER-STANDPIPE
STRUCTURAL
RETAINING WALLS >5' HIGH
PRE-CAST
TRUSS
LANDSCAPE
HAZMAT
FIRM NAME LICENSE #: TELEPHONE #
2012 EDITION OF NC CODE FOR:
EXISTING:
CONSTRUCTED (date): ORIGINAL USE(S) (Ch. 3):
RECONSTUCTION ALTERATION
RENOVATED (date):
REPAIR
NEW CONSTRUCTION UPFITADDITION
BASIC BUILDING DATA:
CONSTRUCTION TYPE: I-A II-A III-A IV V-A
I-B II-B III-B V-B
SPRINKLERS: NO PARTIAL* YES NFPA 13 NFPA 13R NFPA 13D
STANDPIPES: NO YES CLASS I DRYII III WET
FIRE DISTRICT: NO YES (Primary) FLOOD HAZARD AREA: NO YES
BUILDING HEIGHT: NUMBER OF STORIES
GROSS BUILDING AREA:
FLOOR EXISTING BUILDING (SF) NEW ADDITION (SF) SUBTOTAL
TOTAL
ALLOWABLE AREA
ALLOWABLE HEIGHT
BUILDING HEIGHT IN STORIES
BUILDING HEIGHT IN FEET
TYPE OF CONSTRUCTION
ALLOWABLE
(TABLE 503)
INCREASE FOR
SPRINKLERS SHOWN ON PLANS CODE
REFERENCE
FIRE PROTECTION REQUIREMENTS
LIFE SAFETY PLAN SHEET #, IF REQUIRED
STRUCTURAL FRAME,
INCLUDING COLUMNS,
GRIDERS, TRUSSES
FIRE
SEPARATION
DISTANCE
(FEET)
BEARING WALLS
NORTH
EAST
WEST
SOUTH
INTERIOR
NONBEARING WALLS
AND PARTITIONS
EXTERIOR
NORTH
EAST
WEST
SOUTH
EXTERIOR
INT. WALLS & PARTITIONS
FLOOR CONSTRUCTION
INCLUDING SUPPORTING
BEAMS AND JOISTS
ROOF CONSTRUCTION
INCLUDING SUPPORTING
BEAMS AND JOISTS
SHAFT ENCLOSURES - EXIT
SHAFT ENCLOSURES - OTHER
OCCUPANCY SEPARATION
PARTY/FIRE WALL SEPARATION
CORRIDOR SEPARATION
SMOKE BARRIER SEPARATION
TENANT SEPARATION
INCIDENTAL USE SEPARATION
RATING
REQ'D PROVIDED
(w/________*
REDUCTION)
DETAIL #
AND
SHEET #
DESIGN #
FOR RATED
ASSEMBLY
DESIGN #
FOR RATED
PENETRATION
DESIGN #
FOR
RATED
JOINTS
*INDICATES SECTION NUMBER PERMITTING REDUCTION
ZIP CODE:
PHONE:
CONTACT EMAIL:
SMITH SINNETT ARCHITECTURE ROBERT CARMAC NC 10612 (919) 781-8582
1ST FLOOR 0 SF
1200 SF
PRIMARY OCCUPANCY: A-1ASSEMBLY A-2 A-3 A-4 A-5
F-1 MODERATEFACTORYBUSINESS F-2 LOWEDUCATIONAL
H-1 DETONATEHAZARDOUS H-2 DEFLAGRATE H-3 COMBUST H-4 HEALTH H-5 HPM
I-1INSTITUTIONAL I-2 I-3 I-4
11-3 USE CONDITION 2 3 4 5
R-1RESIDENTIAL R-2 R-3 R-4
S-1 MODERATESTORAGE: S-2 LOW
MERCANTILE
UTILITY & MISC PARKING GARAGE OPEN CLOSED
HIGH PILED
REPAIR GARAGE
STORY NO. DESCRIPTION
AND USE
(A)
BLDG AREA
PER STORY
(ACTUAL)
(B)
TABLE 503
AREA
(C)
AREA FOR
FRONTAGE
INCREASE
(D)
AREA FOR
SPRINKLER
INCREASE
(E)
ALLOWABLE
AREA OR
UNLIMITED
(F)
MAXIMUM
BUILDING
AREA
Frontage area increases from Section 506.2 are computed thus:
a. Perimeter which fronts a public way or open space having 20 feet minimum width = _____ (F)
b. Total building perimeter = _____ (P)
c. Ratio (F/P) = _____ ( F/P)
d. W = Minimum width of public way = _____ (W)
e. Percent of frontage increase formula: I = 100[F/P-0.25] x W/30 = _____ (%)
The sprinkler increase per Section 506.3 is as follows:
a. Multi-story building I = 200 percent
b. Single-story building I = 300 percent Unlimited area applicable under conditions of Section 507.
Maximum Building Area = total number of stories in the building x E (506.4) The maximum area of open parking garages must comply with Table 406.3.5. The maximum area of air traffic control towers must comply with Table 412.1.2.f
PROPOSED USE:
FEET
s s
TYPE TYPE
FEET FEET = H + 20' =
STORIES STORIES + 1 = STORIES
BUILDING ELEMENT
14'-9"
V-B V-B
N/A
N/A
N/A N/A
N/A
0 HR
0 HR
0HR
0HR
N/A N/A
FEET
NARENOVATION
CURRENT USE(S) (Ch. 3):
PROPOSED USE(S) (Ch. 3):
ACCESSORY OCCUPANCY: A-1ASSEMBLY A-2 A-3 A-4 A-5
F-1 MODERATEFACTORYBUSINESS F-2 LOWEDUCATIONAL
H-1 DETONATEHAZARDOUS H-2 DEFLAGRATE H-3 COMBUST H-4 HEALTH H-5 HPM
I-1INSTITUTIONAL I-2 I-3 I-4
11-3 USE CONDITION 2 3 4 5
R-1RESIDENTIAL R-2 R-3 R-4
S-1 MODERATESTORAGE: S-2 LOW
MERCANTILE
UTILITY & MISC PARKING GARAGE OPEN CLOSED
HIGH PILED
REPAIR GARAGE
INCIDENTAL USES (Table 508.2.5):
FURNACE ROOM WHERE ANY PIECE OF EQUIPMENT IS OVER 400,000 Btu PER HOUR INPUT ROOMS WITH BOILERS WHERE THE LARGEST PIECE OF EQUIPMENT IS OVER 15 PSI AND 10 HORSEPOWER
REFRIGERANT MACHINE ROOM
HYDROGEN CUTOFF ROOMS, NOT CLASSIFIED AS GROUP H
INCINERATOR ROOMS
PAINT SHOPS, NOT CLASSIFIED AS GROUP H, LOCATED IN OCCUPANCIES OTHER THAN GROUP F LABORATORIES AND VOCATIONAL SHOPS, NOT CLASSIFIED AS GROUP H, LOCATED IN A GROUP E OR I-2 OCCUPANCY
LAUNDRY ROOMS OVER 100 SQUARE FEET
GROUP I-3 CELLS EQUIPPED WITH PADDED SURFACES
GROUP I-2 WASTE AND LINEN COLLECTION ROOMS
WASTE AND LINEN COLLECTION ROOMS OVER 100 SQUARE FEET
STATIONARY STORAGE BATTERY SYSTEMS HAVING A LIQUID ELECTROLYTE CAPACITY OF MORE THAN 50 GALLONS, OR A LITHIUM-ION CAPACITY OF 1,000 POUNDS USED FOR FACILITY STANDBY POWER, EMERGENCY POWER, OR
UNINTERUPTED POWER SUPPLIES
ROOMS CONTAINING FIRE PUMPS
GROUP I-2 STORAGE ROOMS OVER 100 SQUARE FEET
GROUP I-2 COMMERCIAL KITCHENS
GROUP I-2 LAUNDRIES EQUAL TO OR LESS THAN 100 SQUARE FEET
GROUP I-2 ROOMS OR SPACES THAT CONTAIN FUEL-FIRED HEATING EQUIPMENT
EMERGENCY LIGHTING: NO YES
LIFE SAFETY SYSTEM REQUIREMENTS
EXIT SIGNS: NO YES
FIRE ALARM: NO YES
SMOKE DETECTION SYSTEM: NO YES
PANIC HARDWARE: NO YES
PARTIAL
NC NATIONAL GUARD STORAGE BUILDING
NC, LOCATIONS DETERMINED BY OWNER
-- william.s.burriola.mil@mail.mil
(919) 664-6354STORAGE
VARIES
CLIMATE ZONE:
METHOD OF COMPLIANCE:
PRESCRIPTIVE (ENERGY CODE)
ROOF/CEILING ASSEMBLY (EACH ASSEMBLY)
DESCRIPTION OF ASSEMBLY:
ENERGY SUMMARY
PERFORMANCE (ENERGY CODE)
PRESCRIPTIVE (ASHRAE 90.1)
PERFORMANCE (ASHRAE 90.1)
THERMAL ENVELOPE
U-VALUE OF TOTAL ASSEMBLY:
R-VALUE OF INSULATION:
SKYLIGHTS IN EACH ASSEMBLY:
U VALUE OF SKYLIGHT:
TOTAL SQUARE FOOTAGE OF SKYLIGHTS IN EACH ASSEMBLY:
EXTERIOR WALLS (EACH ASSEMBLY)
DESCRIPTION OF ASSEMBLY:
U-VALUE OF TOTAL ASSEMBLY:
R-VALUE OF INSULATION:
OPENINGS (WINDOWS OR DOORS WITH GLAZING)
U VALUE OF ASSEMBLY:
SOLAR HEAT GAIN COEFFICIENT:
PROJECTION FACTOR:
DOOR R-VALUES:
WALLS BELOW GRADE (EACH ASSEMBLY)
DESCRIPTION OF ASSEMBLY:
U-VALUE OF TOTAL ASSEMBLY:
R-VALUE OF INSULATION:
FLOORS OVER UNCONDITIONED SPACE (EACH ASSEMBLY)
DESCRIPTION OF ASSEMBLY:
U-VALUE OF TOTAL ASSEMBLY:
R-VALUE OF INSULATION:
FLOOR SLAB ON GRADE
DESCRIPTION OF ASSEMBLY:
U-VALUE OF TOTAL ASSEMBLY:
R-VALUE OF INSULATION:
HORIZONTAL/VERTICAL REQUIREMENT:
SLAB HEATED:
MECHANICAL SUMMARY
ELECTRICAL SUMMARY
N/A
ROBERT CARMAC
TABLE 601
TABLE 503
TABLE 503
N/A
ENGINEERED DESIGNS INC. TOMAS VELEZ-RIVERA NC 25963 (919) 851-8481
NA
N/A
ROSS LINDEN ENGINEERS
N/A N/A
N/A
1200 SF
1 1200 9,000 N/A N/A NA 9,000
14'-9"N/A N/A 1
0 HR
> 10' N/A> 10' N/A> 10' N/A> 10' N/A> 10'
O HR> 10'
> 10' > 10' > 10' > 10'
N/A N/A N/A N/A N/A
O HR
O HR O HR
O HR O HR
O HR O HR
O HR O HR
0 HR
0 HR
N/A
N/A
0 HR
1200 SF
1200 SF
BRIAN ROSS NC 25539 (919) 832-5680
N/A
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
0.077
NA
NA
6" CONCRETE SLAB OVER VAPOR BARRIER
0.481
(NOT REQUIRED BUT PROVIDED) 7.5
NA
NA
NR
NA
NA
NA
SPECIAL USES 402 403 404 405 406 407 408 409 410
415 416 417 418 419 420
SPECIAL PROVISIONS 509.2 509.3 509.4 509.5 509.6 509.7 509.8
MIXED OCCUPANCY NO YES SEPARATION: EXCEPTION:
INCIDENTAL USE SEPARATION (508.2.5)
THIS SEPARATION IS NOT EXEMPT AS A NON-SEPARATED USE. (SEE EXCEPTIONS)
NON-SEPARATED MIXED OCCUPANCY (508.3.)
THE REQUIRED TYPE OF CONSTRUCTION FOR THE BUILDING SHALL BE DETERMINED BY APPLYING THE HEIGHT AND AREA LIMITATONS FOR EACH OF THE APPLICABLE OCCUPANCIES TO THE ENTIRE BUILDING.
THE MOST RESTRICTIVE TYPE OF CONSTRUCTION, SO DETERMINED, SHALL APPLY TO THE ENTIRE BUILDING.
SEPARATED MIXED OCCUPANCY (508.4) - SEE BELOW FOR AREA CALCULATIONS
FOR EACH STORY, THE AREA OF THE OCCUPANCY SHALL BE SUCH THAT THE SUM OF THE RATIOS OF THE ACTUAL FLOOR AREA OF EACH USE DIVIDED BY THE ALLOWABLE FLOOR AREA FOR EACH USE NOT TO EXCEED 1.
Actual Area of Occupancy A Actual Area of Occupancy B Allowable Area of Occupancy A Allowable Area of Occupancy B+ ≤ 1.00
+ ≤ 1.00
422 423
HR
413 414 424 425 426 427 509.9
LIFE SAFETY PLAN REQUIREMENTS
LIFE SAFETY PLAN SHEET #:
FIRE AND/OR SMOKE RATED WALL LOCATIONS (CHAPTER 7)
ASSUMED AND REAL PROPERTY LINE LOCATIONS
EXTERIOR WALL OPENING AREA WITH RESPECT TO DISTANCE TO ASSUMED PROPERTY LINES (705.8)
EXISTING STRUCTURES WITHIN 30' OF THE PROPOSED BUILDING
OCCUPANCY TYPES FOR EACH AREA AS IT RELATES TO OCCUPANT LOAD CALCULATION (TABLE 1004.1.1)
OCCUPANT LOADS FOR EACH AREA
EXIT ACCESS TRAVEL DISTANCE (1016)
COMMON PATH OF TRAVEL DISTANCE (1014.3 & 1028.8)
DEAD END LENGTHS (1018.4)
CLEAR EXIT WIDTHS FOR EACH EXIT DOOR
MAX. CALCULATED OCC. LOAD CAPACITY EACH EXIT DOOR CAN ACCOMMODATE BASED ON EGRESS WIDTH (1005.1)
ACTUAL OCCUPANT LOAD FOR EACH EXIT DOOR
A SEPARATE SCHEMATIC PLAN INDICATING WHERE FIRE RATED FLOOR/CEILING AND/OR ROOF STRUCTURE IS
PROVIDED FOR PURPOSES OF OCCUPANCY SEPARATION
LOCATION OF DOORS WITH PANIC HARDWARE (1008.1.10)
LOCATION OF DOORS WITH DELAYED EGRESS LOCKS AND THE AMOUNT OF DELAY (1008.1.9.7)
LOCATION OF DOORS WITH ELECTROMAGNETIC EGRESS LOCKS (1008.1.9.8)
LOCATION OF DOORS EQUIPPED WITH HOLD-OPEN DEVICES
LOCATION OF EMERGENCY ESCAPE WINDOWS (1029)
THE SQUARE FOOTAGE OF EACH FIRE AREA (902)
THE SQUARE FOOTAGE OF EACH SMOKE COMPARTMENT (407.4)
NOTE ANY CODE EXCEPTIONS OR TABLE NOTES THAT MAY HAVE BEEN UTILIZED REGARDING THE ITEMS ABOVE
SEE NOTE ON FLOOR PLAN
DESIGN LOADS:
LIVE LOADS: ROOF PSF
EQUIP. PLATFORM PSF
FLOOR PSF
PSFGROUND SNOW LOAD:
IMPORTANCE FACTORS: WIND (I )
SNOW (I )
SEISMIC (I )
BASIC WIND SPEED MPH (ASCE-7)WIND LOAD:
EXPOSURE CATEGORY
WIND BASE SHEARS (FOR MWFRS) V Vx y==
SEISMIC DESIGN CATEGORY
PROVIDE THE FOLLOWING SEISMIC DESIGN PARAMETERS:
SPECTRAL RESPONSE ACCELERATION
SITE CLASSIFICATION (TABLE 1613.5.2)
BASIC STRUCTURAL SYSTEM (CHECK ONE)
BEARING WALL
BUILDING FRAME
MOMENT FRAME
DUAL w/ SPECIAL MOMENT FRAME DUAL w/ INTERMEDIATE R/C OR SPECIAL STEEL
INVERTED PENDULUM
SEISMIC BASE SHEAR: V =
ANALYSIS PROCEDURE:
ARCHITECTURAL, MECHANICAL, COMPONENTS ANCHORED?
S S%g %g
SIMPLIFIED EQUIVALENT LATERAL FORCE DYNAMIC
LATERAL DESIGN CONTROL:
FIELD TEST (PROVIDE COPY OF TEST REPORT)
PRESUMPTIVE BEARING CAPACITY
PILE SIZE, TYPE, AND CAPACITY
PSF
PSF
EARTHQUAKE WIND
(TABLE 2902.1)
USE WATERCLOSETS URINALS LAVATORIES SHOWERS /
TUBS
DRINKING FOUNTAINS
C DB
w s
A x V =y s l e
OCCUPANCY CATEGORY (TABLE 1604.5) III IVIII
A
SPECIAL APPROVALS
STRUCTURAL DESIGN
MALE FEMALE MALE FEMALE REGULAR ACCESSIBLE
SPACE EXISTING
NEW
REQUIRED
TOTAL
UNITS
ACCESSIBLE DWELLING UNITS (SECTION 1107)
ACCESSIBLE
UNITS REQ'D.
ACCESSIBLE
UNITS
PROVIDED
TYPE A
UNITS
REQUIRED
TYPE A
UNITS
PROVIDED
TYPE B
UNITS
REQUIRED
TYPE B
UNITS
PROVIDED
TOTAL
ACCESSIBLE
UNITS PROVIDED
LOT OR
PARKING
AREA
TOTAL # OF PARKING
SPACES
PROVIDED
# OF ACCESSIBLE SPACES PROVIDED
REQUIRED
REGULAR w/ 5'
ACCESS AISLE
TOTAL # OF
ACCESSIBLE
SPACES
PROVIDED
ACCESSIBLE PARKING (SECTION 1106)
VAN SPACES WITH
132" ACCESS AISLE 8' ACCESS AISLE
FIELD TEST PRESUMPTIVE HISTORICAL DATA
B C D E F
DATA SOURCE:
YES NO
SPECIAL INSPECTIONS REQUIRED: YES NO
PLUMBING FIXTURE REQUIREMENTS
SPECIAL APPROVAL: (LOCAL JURISDICTION, DEPARTMENT OF INSURANCE, OSC, DPI, DHHS, ICC, ETC., DESCRIBE BELOW)
SOIL BEARING CAPACITIES:
N/A
N/A
STATE CONSTRUCTION OFFICE
1.0 1.0 1.0 N/A
(slab on grade)
B
7.2k 9.7k
0.35 0.12
4.2k 4.2k
N/A
NA
NC NATIONAL GUARD
N/A
NON-CONDITIONED
ELECTRICAL SYSTEM AND EQIPMENT
LIGHTING SCHEDULE
LAMP TYPE IN FIXTURE
NUMBER OF LAMPS IN FIXTURE
BALLAST TYPE USED IN FIXTURE
NUMBER OF BALLASTS IN FIXTURE
TOTAL WATTAGE PER FIXTURE
SEE LIGHT FIXTURE SCHEDULE
METHOD OF COMPLIANCE:
ENERGY CODE:
ASHRAE 90.1:
XPRESCRIPTIVE PERFORMANCE
PRESCRIPTIVE PERFORMANCE
TOTAL INTERIOR WATTAGE SPECIFIED VS. ALLOWED
TOTAL EXTERIOR WATTAGE SPECIFIED VS. ALLOWED
LIGHTING SCHEDULE
506.2.1 MORE EFFECIENT MECHANICAL EQUIPMENT
506.2.2 REDUCED LIGHTING POWER DENSITY
506.2.3 ENERGY RECOVERY VENTILATION SYSTEMS
506.2.4 HIGHER EFFICIENCY SERVICE WATER HEATER
506.2.5 ON-SITE SUPPLY OF RENEWABLE ENERGY
X
506.2.6 AUTOMATIC DAYLIGHTING CONTROL SYSTEMS
ELECTRICAL DESIGNER STATEMENT
TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE DESIGN OF THIS BUILDING COMPLIES
WITH THE ELECTRICAL SYSTEM AND EQUIPMENT REQUIREMENTS OF THE NORTH
CAROLINA ENERGY CODE 2012 EDITION.
S1
STORAGE (0.36W/FT2 VS 0.63W/FT2) (WHOLE BUILDING)
N/A (NO EXTERIOR LIGHTS SPECIFIED EXCEPT REQUIRED
EMERGENCY EGRESS)
SC
O
4-
6-
A
NOT REQUIRED BUT PROVIDED,
3-1/2" BATT INSULATION BETWEEN RAFTERS
is d raw ing an d t he de sig n s ho wn is the pro pe rty of
Sm ith
Si nn ett Ar ch ite ctu re, P.A . t he re pro du ctio n o r u se of th is pro pe rty wi tho ut the wr itte n c on se nt of the
Arc hit ec t is pr oh ibit ed
. A ny in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub jec t to leg al ac tio n.
Al l co pie s o f th is d raw ing mu st b e r etu rne d t o t he
Ar ch ite ct a t th e co mp let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
ING
IS
FO
RM
AT
TE
D T O
BE
PR
INT
ED
O N A
" X
" S
HE
ET
T 9
1 8
F 9
1 3
La ke
B oo ne Tr ail Su ite
Ra lei gh
, N C inf o@ sm ith sin ne tt.c om
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
F:
\2
\2
-D ra w in gs \re vi t\2
N at G ua rd
S to ra ge
L
AR
G E.
rv t
/10
/20
:23
:21 P
M
G0-03
SPECIFICATIONS
2015004 10 OCT 2016
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
3 9
KDB
DMM/JRC
NC
N
A T
IO
NA
L
G U A R
D
ST
O R A G
E
BL
D G
LA
RG
E
ST
OR
AG
E
BU
IL
DI
NG
NO
RT
H
CA
RO
LI
NA
REGISTEREDARC
HI
TE
CT
UR
AL
CORPORAT ION
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
SC
O
4-
6-
A is d raw ing an d t he de sig n s ho wn is the pro pe rty of
Sm ith
Si nn ett Ar ch ite ctu re, P.A . t he re pro du ctio n o r u se of th is pro pe rty wi tho ut the wr itte n c on se nt of the
Arc hit ec t is pr oh ibit ed
. A ny in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub jec t to leg al ac tio n.
Al l co pie s o f th is d raw ing mu st b e r etu rne d t o t he
Ar ch ite ct a t th e co mp let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
ING
IS
FO
RM
AT
TE
D T O
BE
PR
INT
ED
O N A
" X
" S
HE
ET
T 9
1 8
F 9
1 3
La ke
B oo ne Tr ail Su ite
Ra lei gh
, N C inf o@ sm ith sin ne tt.c om
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
F:
\2
\2
-D ra w in gs \re vi t\2
N at G ua rd
S to ra ge
L
AR
G E.
rv t
/10
/20
:23
:23 P
M
G0-04
SPECIFICATIONS
2015004 10 OCT 2016
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
4 9
KDB
DMM/JRC
NC
N
A T
IO
NA
L
G U A R
D
ST
O R A G
E
BL
D G
LA
RG
E
ST
OR
AG
E
BU
IL
DI
NG
NO
RT
H
CA
RO
LI
NA
REGISTEREDARC
HI
TE
CT
UR
AL
CORPORAT ION
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
SC
O
4-
6-is d raw ing an d t he de sig n s ho wn is the pro pe rty of
Sm ith
Si nn ett Ar ch ite ctu re, P.A . t he re pro du ctio n o r u se of th is pro pe rty wi tho ut the wr itte n c on se nt of the
Arc hit ec t is pr oh ibit ed
. A ny in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub jec t to leg al ac tio n.
Al l co pie s o f th is d raw ing mu st b e r etu rne d t o t he
Ar ch ite ct a t th e co mp let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
ING
IS
FO
RM
AT
TE
D T O
BE
PR
INT
ED
O N A
" X
" S
HE
ET
T 9
1 8
F 9
1 3
La ke
B oo ne Tr ail Su ite
Ra lei gh
, N C inf o@ sm ith sin ne tt.c om
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
F:
\2
\2
-D ra w in gs \re vi t\2
N at G ua rd
S to ra ge
L
AR
G E.
rv t
/10
/20
:23
:25 P
M
G0-05
SPECIFICATIONS
2015004 10 OCT 2016
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
5 9
KDB
DMM/JRC
NC
N
A T
IO
NA
L
G U A R
D
ST
O R A G
E
BL
D G
LA
RG
E
ST
OR
AG
E
BU
IL
DI
NG
NO
RT
H
CA
RO
LI
NA
REGISTEREDARC
HI
TE
CT
UR
AL
CORPORAT ION
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
SC
O
4-
6-
A2 -0
A2 -0
A2 -0
A2 -0
ROOM
2' - 0"
32' - 0" 4' - 0" 4' - 0"
A1-01
A1-01
A1-01
A1-01
40' - 0"
' - 0
PROVIDE (1) #5 VERT. REBAR AT EACH
OVERHEAD DOOR JAMB FROM TOP OF
FTG. TO STEEL LINTEL BEARING
ELEVATION
PROVIDE BACKER RODS AND
SEALANT ON EACH FACE OF WALL
CONTROL JOINTS, TYP.
PROVIDE (1) #5 VERT. REBAR AT
EACH BLDG. CONTROL JOINT FROM
TOP OF FTG. TO TOP OF CMU WALL
ELEVATION. SEE STRUCTURAL
ELECTRICAL CONDUIT SLEEVE IN
CMU WALL FOR SERVICE ENTRANCE.
VERIFY LOCATION SPECIFIC TO EACH
SITE AND RELOCATE AS NECESSARY
FOR SITE ADAPTATION.
CJ
CJ
PROVIDE (1) #5 VERT. REBAR AT EACH
HM. DR. JAMB FROM TOP OF FTG. TO
MASONRY LINTEL BEARING ELEVATION.
FOLLOW MFR's INSTRUCTIONS FOR
ANCHORING THE HM. DR. FRAME INTO
THE CMU JAMBS. PROVIDE SEALANT
ON EACH FACE OF DOOR FRAME ALL
AROUND.
EXTEND FLOOR SLAB TO EXTERIOR AT
HM. DR. LOCATIONS. EMBED DOOR
THRESHOLD IN SEALANT BEAD.
DASHED LINE INDICATES
OVERHANG LINE
DOOR: 3'-8" x 7'-0" OPENING: 4' x 7'-4"
DOOR: 3'-8" x 7'-0" OPENING: 4' x 7'-4"
DS
6' x 12', 6"
CONCRETE
PAD W.W.F.
4' - 0"
4' - 0"
' - 0
' - 0
' - 0
STEEL BOLLARDS, TYP. EACH SIDE OF
O.H. DOOR - SEE DETAIL 7/A5-01
1/4" / 12"
CJ
DS
DSDS
PROVIDE (1) VERT. #5 REBAR AT 32"
O.C. BETWEEN THE 1ST COURSE OF
CMU's. EXTEND CJ's FROM TOP OF CONC. FTG's TO TOP OF WALL. SEE
STRUCTURAL
PROVIDE (1) VERT. #5 REBAR AT EACH
BLDG. CORNER FROM TOP OF FTG. TO
TOP OF CMU WALL ELEVATION. SEE
STRUCTURAL
OPTIONAL DOOR RELOCATION FOR
SITE SPECIFIC ADAPATION
OPTIONAL DOOR RELOCATION
FOR SITE SPECIFIC ADAPATION
FIRE EXTINGUISHER BRACKET
1' - 6" 1' - 6"
' - 3
A5-01
SIM
A5-01
SIM
A5-01
SIM
OPTION: ALTERNATE ELECTRIAL
SERVICE LOCATION
ALTERNATE LOCATION:
PREFINISHED DOWNSPOUT
ALTERNATE LOCATION:
PREFINISHED DOWNSPOUT
SEE STRUCTURAL
DWGS. FOR CONTROL
JOINT LOCATIONS
A1-01
A3-01
TRUSS
BEARING
' - 1
1/ 2"
OPTIONAL DOOR RELOCATION FOR
SITE SPECIFIC ADAPATION.
A1-01
A3-01
TRUSS
BEARING
' - 1
1/ 2"
6"
12"
OPTIONAL DOOR RELOCATION FOR
SITE SPECIFIC ADAPATION
ALTERNATE LOCATION:
PREFINISHED DOWNSPOUT
GUTTERS & DOWNSPOUTS
ROOF + WALL PANEL COLOR
FRAME AND DOOR COLOR
COILING DOOR COLOR
CUSTOM CMU COLOR
MORTAR COLOR
STEEL DOOR LINTEL
MATERIAL FINISH OPTION 1
MATCH ROOF COLOR
EVERGREEN
MATCH ROOF COLOR
MATCH ROOF COLOR
MAROUS BLEND
MATCH MASONRY
MATCH ROOF COLOR
FINISH OPTION 2 FINISH OPTION 3
MATCH ROOF COLOR
MANSARD BROWN
MATCH ROOF COLOR
MATCH ROOF COLOR
RICHFIELD BLEND
MATCH MASONRY
MATCH ROOF COLOR
MATCH ROOF COLOR
COLONIAL RED
MATCH ROOF COLOR
MATCH ROOF COLOR
AUTUMN BLEND
MATCH MASONRY
MATCH ROOF COLOR
NOTE: - BASIS OF DESIGN FOR COLOR SELECTION
- CUSTOM CMU - QUIK BRIK OR EQUAL
- ROOF PANEL - UNION CORRUGATING COMPANY
- STL. LINTEL PAINT TO MATCH ADJACENT FRAME FINISH
- MORTAR COLOR AS SPECIFIED BY MANUFACTURER
of
Th is d raw ing an d t he de sig n s ho wn is the pro pe rty of
Sm ith
Si nn ett Ar ch ite ctu re, P.A . t he re pro du ctio n o r u se of th is pro pe rty wi tho ut the wr itte n c on se nt of the
Arc hit ec t is pr oh ibit ed
. A ny in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub jec t to leg al ac tio n.
Al l co pie s o f th is d raw ing mu st b e r etu rne d t o t he
Ar ch ite ct a t th e co mp let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
ING
IS
FO
RM
AT
TE
D T O
BE
PR
INT
ED
O N A
" X
" S
HE
ET
T 9
1 8
F 9
1 3
La ke
B oo ne Tr ail Su ite
Ra lei gh
, N C inf o@ sm ith sin ne tt.c om
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
F:
\2
\2
-D ra w in gs \re vi t\2
N at G ua rd
S to ra ge
L
AR
G E.
rv t
/10
/20
:23
:14 P
M
A1-01
FLOOR PLAN
2015004 10 OCT 2016
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
6 9
KDB
DMM/JRC
NC
N
A T
IO
NA
L
G U A R
D
ST
O R A G
E
BL
D G
LA
RG
E
ST
OR
AG
E
BU
IL
DI
NG
NO
RT
H
CA
RO
LI
NA
REGISTEREDARC
HI
TE
CT
UR
AL
CORPORAT ION
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
1/4" = 1'-0"A1-01
1 FLOOR PLAN
1/4" = 1'-0"A1-01
2 SECTION - LONGITUDINAL
1/4" = 1'-0"A1-01
3 SECTION - TRANSVERSE
NOTES:
• SUBMIT SHOP DRAWINGS FOR ROOF TRUSS SYSTEM DESIGN THAT IS SIGNED, DATED AND SEALED
BY A LICENSED NORTH CAROLINA PROFESSIONAL ENGINEER FOR APPROVAL, PRIOR TO
FABRICATION.
• WOOD ROOF TRUSSES WITH 1'-6" OVERHANG ON ALL SIDES. PROVIDE OPENING IN ROOF
DIAPHRAGM FOR A CONTINUOUS RIDGE VENT. PROVIDE 2X CANTILEVERD OUTRIGGERS OVER GABLE WALL FRAMING. ALL FRAMING, BRIDGING, BLOCKING, BRACING, FASTENERS, CONNECTORS AND ROOF SHEATHING ATTACHMENT SHALL BE DESIGNED AND FURNISHED BY THE ROOF TRUSS SYTEM
MFG. PER THE CURRENT NORTH CAROLINA STATE BUILDING CODE.
SC
O
4-
6-
A
1/4" = 1'-0"
FINISH LEGEND4
A1-01
0 1' 2' 3'
A1-01
FINISHED GRADEOPTIONAL DOOR RELOCATION FOR
SITE SPECIFIC ADAPATION.
6" STEEL CONCRETE FILLED BOLLARD
WITH PLASTIC COVER, 7/A5-01
OPTION: 25' BLACK CORRUGATED
PIPE TO DAYLIGHT, TYP.
PREFINISHED METAL RIDGE VENT
PREFINISHED METAL ROOF PANELS
PREFINISHED GUTTER AND DOWNSPOUTS
1'-6" ENDWALL OVERHANG
OPTION: METAL DOWNSPOUT BOOT W/
CONCEALED CLEANOUT, 1/A5-01
ALTERNATE LOCATION: PREFINISHED
DOWNSPOUT
INTEGRAL CUSTOM CMU W/ MATCHING
COLORED MORTAR
CJ
ANGLED DOWNSPOUT WITH SPLASH BLOCK
A1-01
FULL CUT-OFF AREA LIGHT
PREFINISHED OVERHEAD COILING DOOR
PREFINISHED METAL WALL PANELS
PREFINISHED TRIM
1'-6" SIDEWALL OVERHANG
ALTERNATE LOCATION:
PREFINISHED DOWNSPOUT
OPTION: METAL DOWNSPOUT BOOT W/
CONCEALED CLEAN OUT, 1/A5-01
FINISHED GRADE LINE
' - 1
1/ 2"
TRUSS
BEARING
6"
12"
EPOXY PAINT ON H.M. DOOR
AND FRAME
25' BLACK CORRUGATED
PIPE TO DAYLIGHT, TYP.
OPTIONAL DOOR RELOCATION FOR SITE
SPECIFIC ADAPATION
INTEGRAL CUSTOM CMU W/
MATCHING COLORED MORTAR
14"x24" ALUMINUM GABLE VENT W/ 50%
FREE AREA. INCLUDE INSECT SCREEN
6" STEEL CONCRETE FILLED BOLLARD
WITH PLASTIC COVER, 7/A5-01
EXTERIOR EMERGENCY EGRESS
LIGHT FIXTURE
ANGLED DOWNSPOUT WITH
SPLASH BLOCK
CJ CJ
A1-01
6"
12"
PREFINISHED METAL WALL PANELS
PREFINISHED TRIM
1'-6" SIDEWALL OVERHANG
PREFINISHED DOWNSPOUT
ANGLED DOWNSPOUT WITH
SPLASH BLOCK
FINISHED GRADE LINE
OPTION: 25' BLACK
CORRUGATED PIPE TO
DAYLIGHT, TYP.
INTEGRAL CUSTOM CMU W/
MATCHING COLORED MORTAR
14"x24" ALUMINUM GABLE VENT W/ 50%
FREE AREA. INCLUDE INSECT SCREEN
CJ
OPTION: METAL DOWNSPOUT BOOT
W/ CONCEALED CLEAN OUT, 1/A5-01
A1-01
PREFINISHED METAL RIDGE VENT
PREFINISHED METAL ROOF PANELS
PREFINISHED GUTTER AND DOWNSPOUTS
1'-6" ENDWALL OVERHANG
ANGLED DOWNSPOUT WITH SPLASH
BLOCK
FINISHED GRADE
PREFINISHED DOWNSPOUT
OPTION: 25' BLACK CORRUGATED
PIPE TO DAYLIGHT, TYP.
INTEGRAL CUSTOM CMU W/ MATCHING
COLORED MORTAR
6" STEEL CONCRETE FILLED BOLLARD
WITH PLASTIC COVER, 7/A5-01
EXTERIOR EMERGENCY EGRESS
LIGHT FIXTURE
CJ
OPTION: METAL DOWNSPOUT BOOT W/
CONCEALED CLEANOUT, 1/A5-01
ALTERNATE LOCATION:
PREFINISHED DOWNSPOUT
of
Th is d raw ing an d t he de sig n s ho wn is the pro pe rty of
Sm ith
Si nn ett Ar ch ite ctu re, P.A . t he re pro du ctio n o r u se of th is pro pe rty wi tho ut the wr itte n c on se nt of the
Arc hit ec t is pr oh ibit ed
. A ny in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub jec t to leg al ac tio n.
Al l co pie s o f th is d raw ing mu st b e r etu rne d t o t he
Ar ch ite ct a t th e co mp let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
ING
IS
FO
RM
AT
TE
D T O
BE
PR
INT
ED
O N A
" X
" S
HE
ET
T 9
1 8
F 9
1 3
La ke
B oo ne Tr ail Su ite
Ra lei gh
, N C inf o@ sm ith sin ne tt.c om
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
F:
\2
\2
-D ra w in gs \re vi t\2
N at G ua rd
S to ra ge
L
AR
G E.
rv t
/10
/20
:23
:16 P
M
A2-01
BUILDING
ELEVATIONS
2015004 10 OCT 2016
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
7 9
KDB
DMM/JRC
NC
N
A T
IO
NA
L
G U A R
D
ST
O R A G
E
BL
D G
LA
RG
E
ST
OR
AG
E
BU
IL
DI
NG
NO
RT
H
CA
RO
LI
NA
REGISTEREDARC
HI
TE
CT
UR
AL
CORPORAT ION
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
1/4" = 1'-0"A2-01
2 ELEVATION - LEFT SIDEWALL
1/4" = 1'-0"A2-01
1 ELEVATION - FRONT ENDWALL
1/4" = 1'-0"A2-01
3 ELEVATION - REAR ENDWALL
1/4" = 1'-0"A2-01
4 ELEVATION - RIGHT SIDEWALL
NOTE:
• PAINT ALL EXPOSED WOOD TRIM
• PAINT ALL EXPOSED METAL NOT PREFINISHED
SC
O
4-
6-
ROOF TRUSS (DESIGN BY MFG. TO COMPLY WITH NC SBC)
PREFINISHED 26 GA. GALV. METAL ROOF W/ EXPOSED
FASTENERS OVER AIR AND WATER BARRIER ON 1/2"
PLYWOOD SHEATHING W/ 28 GA. WOOD GABLE AND FASCIA
TRIM BOARDS AND RIDGE VENT
3-1/2" BATT WALL INSULATION (UNFACED) WITHIN
GABLE AREA
PREFINISHED METAL WALL PANELS OVER AIR AND WATER
BARRIER AND 1/2" PLYWOOD SHEATHING ON END WALL
TRUSS (DESIGN BY MFG. TO COMPLY W/ NC SBC)
GABEL BEYOND
OVERHEAD STEEL COILING DOOR WITH LOCK. MOUNT
TO CMU WALL WITH EXPANSION BOLTS PER MFG.
INSTRUCTIONS.
PREFINISHED METAL DRIP EDGE TRIM
BELOW ROOF PANELS
DOUBLE 4" BOND BEAM (8") AT OVERHEAD DOOR
STEEL BEAM LINTEL W/ STEEL PLATE AT HEAD, SEE
STRUCTURAL. PAINTED
6" CONCRETE SLAB W/ WIRE MESH REINFORCEMENT.
SLOPE DOWN 1/4" PER 12" AWAY FROM BUILDING.
EXPANSION JOINT AT OVERHEAD DOOR
RECESSED CONCRETE FLOOR SLAB 1" AT OVERHEAD
DOOR SILL. SLOPE TO DRAIN
6" STEEL CONCRETE FILLED BOLLARD WITH PLASTIC
COVER, 7/A5-01
1/4" / 12"
EXTERIOR EMERGENCY EGRESS LIGHT FIXTURE, SEE
ELECTRICAL
14"x24" ALUMINUM GABLE VENT W/ 50% FREE AREA.
INCLUDE INSECT SCREEN
2"x4" OUTRIGGER
1 1/2" POLYISOCYANURATE
PERIMETER INSULATION
A3-01
FULL CUT-OFF AREA LIGHT
PREFINISHED 26 GA. GALV. METAL ROOF W/ EXPOSED
FASTENERS, PREFINISHED METAL TRIM, DRIP EDGE, ON
SHEATHING
ROOF TRUSS (DESIGN BY MFG. TO COMPY WITH NC SBC)
3-1/2" UNFACED FIBERGLASS BATT ROOF INSULATION
GALVANIZED ROOF TRUSS CONNECTION PLATES PER
TRUSS MFG.
A3-01
CUSTOM CMU WALL W/ WIRE MESH EVERY 4TH COURSE (@ 16"
O.C.) AND 3/8" CONCAVE MORTAR JOINTS
6' CONCRETE FLOOR SLAB W/ 6"x6" / W2.9 x W2.9 WIRE MESH
15 MIL VAPOR BARRIER BELOW FLOOR SLAB
5" OF WASHED #57 STONE ON COMPACTED EARTH
OPTION: METAL DOWNSPOUT BOOT W/ CONCEALED
CLEANOUT, 1/A5-01
FINISH GRADE TO BE 6" BELOW FINISHED FLOOR SLAB AND
SLOPE AWAY FROM BUILDING
OPTION: EXTEND DOWNSPOUT W/ SS CLAMP ON 25' OF 4"
BLACK CORRUGATED PIPE TO DAYLIGHT, TYP. SLOPE DRAIN
DOWN 1/4:12 MIN. TO DAYLIGHT BEYOND BUILDING.
2"x8" TREATED WOOD TOP PLATE WITH HURRICANE CLIP
DOUBLE 4" BOND BEAM (8")
2"x4" WOOD FRAMING W/ PREFINISHED PERFORATED METAL
SOFFI T PANELS
PREFINISHED 6" GUTTER W/ EXPANSION SUPPORTS AT 4'-0"
O.C. AND 6" DOWNSPOUTS
PREFINISHED METAL DRIP EDGE TRIM BELOW ROOF PANELS
PREFINISHED METAL OVER 1"x8" TREATED WOOD FACE TRIM
6"
12"
A3-01
ANGLED DOWNSPOUT WITH SPLASH BLOCK
CONNECTOR AT EACH PIECE OF SHAPED BLOCKING
2"x6" SHAPED BLOCKING EVERY OTHER TRUSS
1/2" DIA. ANCHOR BOLTS (THREADED ROD W/ NUT
AND WASHER @ 24" SPACING) INTO 2"x8" TREATED
WOOD TOP PLATE, DOUBLE 4" BOND BEAM (8") W/
(2) #5 HORIZONTAL BARS
18 GA. HURRICANE ANCHOR AT EACH ROOF TRUSS
1" MIN. GAP ABOVE INSULATION FOR CONDENSATION VENTILATION.
FIBERGLASS INSULATION BETWEEN TRUSS TOP CORD SUPPORTED
BY TIGER WIRE
6"
12"
PREFINISHED 26 GA. GALV. METAL ROOF W/ EXPOSED FASTENERS,
PREFINISHED METAL TRIM, DRIP EDGE, ON SHEATHING
ROOF TRUSS (DESIGN BY MFG. TO COMPY WITH NC SBC)
3-1/2" UNFACED FIBERGLASS BATT ROOF INSULATION
CUSTOM CMU WALL W/ WIRE MESH EVERY 4TH COURSE (@ 16"
O.C.) AND 3/8" CONCAVE MORTAR JOINTS
PREFINISHED 6" GUTTER W/ EXPANSION SUPPORTS AT
4'-0" O.C. AND 6" DOWNSPOUTS
PRFINISHED PERFORATED METAL SOFFIT
1"x8" FACIA BOARD
2 8
2"x6" WOOD FRAMING
2"x4" WOOD FRAMING, TREATED WOOD WHEN IN
CONTACT W/ MASONRY
ROOF DRAIN LEADER
ANGLED DOWNSPOUT
WITH SPLASH BLOCK
OPTION: METAL DOWNSPOUT
BOOT W/ CONCEALED
CLEANOUT, 1/A5-01
1 1/2" POLYISOCYANURATE
PERIMETER INSULATION,
TYP.
1' - 0"
2' - 0"
CONCRETE FOOTING,
REFER TO STRUCTURAL
1/2" EXPANSION JOINT
BETWEEN CONCRETE SLAB
AND WALL
2 8
ROLL-UP DOOR COIL SHROUD
STEEL BEAM LINTEL W/ STEEL
PLATE AT HEAD, SEE
STRUCTURAL, PAINTED
DOOR FRAME/WALL BEYOND
1/2" DIA. ANCHOR BOLTS
(THREADED ROD W/ NUT AND
WASHER @ 24" SPACING) INTO
2"x8" TREATED WOOD TOP
PLATE, DOUBLE 4" BOND BEAM
(8") W/ (2) #5 HORIZONTAL BARS
8' - 0" BOTTOM OF
STEEL LINTEL
PREFINISHED METAL WALL
PANELS OVER AIR AND WATER
BARRIER AND 1/2" PLYWOOD
SHEATHING ON END WALL TRUSS
(DESIGN BY MFG. TO COMPLY W/
NC SBC)
MASONRY BOND BEAM UNITS
PER MANUF.
1/2" of
Th is d raw ing an d t he de sig n s ho wn is the pro pe rty of
Sm ith
Si nn ett Ar ch ite ctu re, P.A . t he re pro du ctio n o r u se of th is pro pe rty wi tho ut the wr itte n c on se nt of the
Arc hit ec t is pr oh ibit ed
. A ny in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub jec t to leg al ac tio n.
Al l co pie s o f th is d raw ing mu st b e r etu rne d t o t he
Ar ch ite ct a t th e co mp let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
ING
IS
FO
RM
AT
TE
D T O
BE
PR
INT
ED
O N A
" X
" S
HE
ET
T 9
1 8
F 9
1 3
La ke
B oo ne Tr ail Su ite
Ra lei gh
, N C inf o@ sm ith sin ne tt.c om
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
F:
\2
\2
-D ra w in gs \re vi t\2
N at G ua rd
S to ra ge
L
AR
G E.
rv t
/10
/20
:23
:18 P
M
A3-01
WALL SECTIONS
2015004 10 OCT 2016
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
8 9
KDB
DMM/JRC
NC
N
A T
IO
NA
L
G U A R
D
ST
O R A G
E
BL
D G
LA
RG
E
ST
OR
AG
E
BU
IL
DI
NG
NO
RT
H
CA
RO
LI
NA
REGISTEREDARC
HI
TE
CT
UR
AL
CORPORAT ION
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
3/4" = 1'-0"A3-01
1 WALL SECTION - OVERHEAD DOOR
3/4" = 1'-0"A3-01
3 WALL SECTION - SIDE WALL
1 1/2" = 1'-0"A3-01
4 TRUSS/WALL ANCHOR DETAIL
NOTES:
• BOTTOM OF FOOTINGS SHALL BE 12" MINIMUM BELOW THE UNDISTRUBED GROUND SURFACE
• FINISHED GRADE SHALL BE 6" MINIMUM BELOW FLOOR LEVEL ALL AROUND
• PROVIDE A SWALE WHERE NEEDED TO DIRECT WATER AWAY FROM BUILDING
• WHERE GROUND WATER RISES TO WITHIN 6" OF THE FINSHED GRADE FOUNDATION DRAINS SHALL BE
PROVIDED
SC
O
4-
6-
A
1 1/2" = 1'-0"A3-01
2 SIDE WALL FOUNDATION DETAIL
1 1/2" = 1'-0"A3-01
5 OVERHEAD DOOR HEAD DETAIL
2"
HOLLOW METAL DOOR
FRAME - FILL SOLID W/
GROUT
GALV. CORR. ANCHORS
SET IN CMU
1/2" RETURN
EQ
EQ
FILL CMU SOLID W/
CONCRETE
SEALANT, ENTIRE
PERIMETER EA.
SIDE
3/
4"
#5 REBAR FROM
FOOTING CONT. TO
LINTEL
U.O .N.
7 5 /8"
WALL BEYOND
FINISHED FLOOR
AS SCHED.
SLOPE:
THRESHOLD SET IN
MASTIC
HM FRAME & DOOR
1/4" PER FOOT
8 3/4"
2" 3' - 8" 2"
4"
AS
SC
HE
DU
LE
D
HM1
HOLLOW METAL
FRAME W/ FLUSH
DOOR
COH
COILING OVERHEAD
DOOR FRAME
8 3/4"
CMU
LINTEL BEAM - SEE
STRUCT. FOR
REINFORCING
H.M. FRAME
- FILL SOLID
W/ GROUT
RAKE AND
SEALANT, TYP.
7 5/8"
2"
4" CMU
STEEL BEAM
LINTEL, SEE
STRUCTURAL
0.375" STEEL PLATE
RAKE AND
SEALANT, TYP.
7 5/8"
D1
TYP
AS SCHEDULED
TY
P
AS
SC
HE
DU
LE
D
OH COILING DOOR
AS SCHEDULED
NOTE: REFER TO
FLOOR PLAN SHEET
A1-01 FOR QUANTITIES
FILL PIPE SOLID W/
CONC. AND ROUND
SMOOTH (ROUGH TOP
SURFACE WILL NOT
BE PERMITTED)
6" PIPE BOLLARD
2' - 6"
MI
N4"
3" MIN 3" MIN
PROVIDE CONTROL
JOINT AROUND
BOLLARD, REFER TO
STRUCTURAL DWGS.
VINYL SLEEVE
OVER BOLLARD
14" DIAM CONC.
ENCASEMENT
7 3/4"
INTERIOR:
4"x5"36
" M
IN
CONNECT TO 25' BLACK
CORRUGATED PIPE
DOWNSPOUT
10" +/-
24" +/-
PRE-CAST
CONCRETE SPLASH
BLOCK
3'-6"x4'-0" 60 MIL SINGLE PLY. WALK OFF
MEMBRANE PATCH UNDER SPLASH
BLOCKS ON ROOFS
**(TYPICAL AT ALL ROOF DRAIN LEADERS DRAINING ONTO A
LOWER ROOF FROM A HIGHER ROOF.)
JOINT REINF. DISCONTINUOUS @
CONTROL JOINT
CMU SASH BLOCK
CONTROL JOINT MATERIAL
SEALANT W/ BACKER ROD
EACH SIDE
FILL CMU CELL SOLID AND
REINFORCE AS SHOWN ON
STRUCTURAL DRAWINGS EACH SIDE
OF CONTROL JOINT.
3/8" TYP.
of
Th is d raw ing an d t he de sig n s ho wn is the pro pe rty of
Sm ith
Si nn ett Ar ch ite ctu re, P.A . t he re pro du ctio n o r u se of th is pro pe rty wi tho ut the wr itte n c on se nt of the
Arc hit ec t is pr oh ibit ed
. A ny in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub jec t to leg al ac tio n.
Al l co pie s o f th is d raw ing mu st b e r etu rne d t o t he
Ar ch ite ct a t th e co mp let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
ING
IS
FO
RM
AT
TE
D T O
BE
PR
INT
ED
O N A
" X
" S
HE
ET
T 9
1 8
F 9
1 3
La ke
B oo ne Tr ail Su ite
Ra lei gh
, N C inf o@ sm ith sin ne tt.c om
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
F:
\2
\2
-D ra w in gs \re vi t\2
N at G ua rd
S to ra ge
L
AR
G E.
rv t
/10
/20
:23
:19 P
M
A5-01
DOOR SCHEDULE,
DOOR ELEVATIONS,
DETAILS
2015004 10 OCT 2016
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
9 9
KDB
DMM/JRC
NC
N
A T
IO
NA
L
G U A R
D
ST
O R A G
E
BL
D G
LA
RG
E
ST
OR
AG
E
BU
IL
DI
NG
NO
RT
H
CA
RO
LI
NA
REGISTEREDARC
HI
TE
CT
UR
AL
CORPORAT ION
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
DOOR SCHEDULE
DOOR FRAME
HARDWARE
SET FIRE RATING REMARKSMARK
DOOR SIZE
MAT TYPE LVS MAT TYPE
DETAILS
WIDTH HEIGHT THK HEAD JAMB THRESH
100 3' - 8" 7' - 0" 1 3/4" HM D1 0 HM HM1 6/A5-01 5/A5-01 8/A5-01 1 0 HR INCLUDE DOOR SWEEP AND BOTTOM DRIP EDGE; DRIP EDGE AT TOP 101 3' - 8" 7' - 0" 1 3/4" HM D1 0 HM HM1 6/A5-01 5/A5-01 8/A5-01 1 0 HR INCLUDE DOOR SWEEP AND BOTTOM DRIP EDGE; DRIP EDGE AT TOP 102 10' - 0" 8' - 1" 1/2" Overhead Door as Specified in 08 36 00 COH 4/A5-01 5/A5-01 8/A5-01 0 HR
3" = 1'-0"A5-01
5 TYPICAL HOLLOW METAL FRAME
1 1/2" = 1'-0"A5-01
8 TYP. EXTERIOR DOOR THRESHOLD
1/4" = 1'-0"
DOOR & FRAME ELEVATIONS
1 1/2" = 1'-0"A5-01
6 HM HEAD @ 8" CMU
1 1/2" = 1'-0"A5-01
4 HEAD @ O.H. DOOR
1/4" = 1'-0"
DOOR LEGEND
SC
O
4-
6-
A
1" = 1'-0"A5-01
7 BOLLARD DETAIL
1" = 1'-0"A5-01
1 CAST IRON DOWNSPOUT BOOT
OPTION: CHOOSE 1
1/4" = 1'-0"A5-01
3 SPLASH BLOCK AT DOWNSPOUT
1" = 1'-0"A5-01
2 BLOCK PARTITION CONTROL JOINT
This acquisition is reserved for small business concerns. This combined synopsis/solicitation is in accordance with FAR 12.6. The North American Industry Classification system code (NAICS) 423330 size standard of 200 employees..
CLAUSES INCORPORATED BY REFERENCE
52.204-13 System for Award Management Maintenance 52.204-19 Incorporation by Reference of Representations and Certifications.
P- 52.211-6-- Brand Name or Equal P- 52.212-1, Instructions to Offerors P- 52.212-3, Offerors Representations and Certifications – Commercial Items 52.212-4 Contract Terms and Conditions--Commercial Items 52.222-50 Combating Trafficking in Persons 52.232-39 Unenforceability of Unauthorized Obligations 52.232-40 Providing Accelerated Payments to Small Business Subcontractors 252.203-7000 Requirements Relating to Compensation of Former DoD Officials 252.203-7002 Requirement to Inform Employees of Whistleblower Rights 252.204-7003 Control Of Government Personnel Work Product 252.204-7006 Billing Instructions 252.204-7012 Safeguarding Covered Defense Information and Cyber Incident Reporting 252.204-7015 Notice of Authorized Disclosure of Information for Litigation Support 252.223-7008 Prohibition of Hexavalent Chromium 252.225-7001 Buy American And Balance Of Payments Program-- Basic 252.225-7002 Qualifying Country Sources As Subcontractors 252.225-7048 Export-Controlled Items 252.232-7003 Electronic Submission of Payment Requests and Receiving Reports 252.232-7010 Levies on Contract Payments 252.237-7010 Prohibition on Interrogation of Detainees by Contractor Personnel 252.243-7001 Pricing Of Contract Modifications 252.244-7000 Subcontracts for Commercial Items 252.247-7023 Transportation of Supplies by Sea
CLAUSES INCORPORATED FULL TEXT
P- 52.212-2, Evaluation—Commercial Items: The Government will award a firm-fixed priced contract to a small business. Only one award will be made. The Government intends to award a firm-fixed price contract to the responsible vendor whose quote conforming to the solicitation provides the Best Value to the Government. “Best value” means the expected outcome of an acquisition that, in the Government’s estimation, provides the greatest overall benefit in response to the requirement. In accordance with FAR
12.602 & FAR 13.106-2, technical, price & readily available past performance information will be considered in the streamlined evaluation. This may result in award being made to a higher-rated, higher-priced quote. The Government’s selection of a higher-rated, higher-priced quote will be supported by a determination that the technical/past performance superiority warrants the additional cost involved.
Offerors are encouraged to submit past performance references.
52.219-28 , Post-Award Small Business Program Rerepresentation 52.252-2, Clauses Incorporated by Reference 52.252-6, Authorized Deviations in Clauses 252.232-7006, Wide Area Workflow
52.212-5 CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE
ORDERS--COMMERCIAL ITEMS
(a) The Contractor shall comply with the following Federal Acquisition Regulation (FAR) clauses, which are incorporated in this contract by reference, to implement provisions of law or Executive orders applicable to acquisitions of commercial items:
(1) 52.203-19, Prohibition on Requiring Certain Internal Confidentiality Agreements or Statements (JAN 2017) (section 743 of Division E, Title VII, of the Consolidated and Further Continuing Appropriations Act, 2015 (Pub. L. 113-235) and its successor provisions in subsequent appropriations acts (and as extended in continuing resolutions)).
(2) 52.204-23, Prohibition on Contracting for Hardware, Software, and Services Developed or Provided by Kaspersky Lab and Other Covered Entities (Jul 2018) (Section 1634 of Pub. L. 115-91).
(3) 52.209-10, Prohibition on Contracting with Inverted Domestic Corporations (Nov 2015).
(4) 52.233-3, Protest After Award (AUG 1996) (31 U.S.C. 3553).
(5) 52.233-4, Applicable Law for Breach of Contract Claim (OCT 2004) (Public Laws 108-77 and 108-78 (19 U.S.C. 3805 note)).
(b) The Contractor shall comply with the FAR clauses in this paragraph (b) that the Contracting Officer has indicated as being incorporated in this contract by reference to implement provisions of law or Executive orders applicable to acquisitions of commercial items: (Contracting Officer check as appropriate.)
___ (1) 52.203-6, Restrictions on Subcontractor Sales to the Government (Sept 2006), with Alternate I (Oct 1995) (41 U.S.C. 4704 and 10 U.S.C. 2402).
____ (2) 52.203-13, Contractor Code of Business Ethics and Conduct (Oct 2015) (41 U.S.C. 3509).
X (3) 52.203-15, Whistleblower Protections under the American Recovery and Reinvestment Act of 2009 (June 2010) (Section 1553 of Pub. L. 111-5). (Applies to contracts funded by the American Recovery and Reinvestment Act of 2009.)
X (4) 52.204-10, Reporting Executive Compensation and First-Tier Subcontract Awards (Oct 2018) (Pub. L.
109-282) (31 U.S.C. 6101 note).
___ (5) [Reserved]
___ (6) 52.204-14, Service Contract Reporting Requirements (Oct 2016) (Pub. L. 111-117, section 743 of Div. C).
___ (7) 52.204-15, Service Contract Reporting Requirements for Indefinite-Delivery Contracts (Oct 2016) (Pub. L. 111-117, section 743 of Div. C).
X (8) 52.209-6, Protecting the Government's Interest When Subcontracting with Contractors Debarred, Suspended, or Proposed for Debarment. (Oct 2015) (31 U.S.C. 6101 note).
____ (9) 52.209-9, Updates of Publicly Available Information Regarding Responsibility Matters (Oct 2018) (41 U.S.C. 2313).
____ (10) [Reserved]
____ (11)(i) 52.219-3, Notice of HUBZone Set-Aside or Sole-Source Award (NOV 2011) (15 U.S.C. 657a).
____ (ii) Alternate I (NOV 2011) of 52.219-3.
____ (12) (i) 52.219-4, Notice of Price Evaluation Preference for HUBZone Small Business Concerns (OCT 2014) (if the offeror elects to waive the preference, it shall so indicate in its offer) (15 U.S.C. 657a).
____ (ii) Alternate I (JAN 2011) of 52.219-4.
____ (13) [Reserved]
X (14)(i) 52.219-6, Notice of Total Small Business Set-Aside (DEVIATION 2019-O00003)
____ (ii) Alternate I (NOV 2011).
____ (iii) Alternate II (NOV 2011).
____ (15)(i) 52.219-7, Notice of Partial Small Business Set-Aside (June 2003) (15 U.S.C. 644).
____ (ii) Alternate I (Oct 1995) of 52.219-7.
____ (iii) Alternate II (Mar 2004) of 52.219-7.
____ (16) 52.219-8, Utilization of Small Business Concerns (Oct 2018) (15 U.S.C. 637(d)(2) and (3)).
____ (17)(i) 52.219-9, Small Business Subcontracting Plan (Aug 2018) (15 U.S.C. 637(d)(4)).
____ (ii) Alternate I (Nov 2016) of 52.219-9.
____ (iii) Alternate II (Nov 2016) of 52.219-9.
____ (iv) Alternate III (Nov 2016) of 52.219-9.
____ (v) Alternate IV (Aug 2018) of 52.219-9.
____ (18) 52.219-13, Notice of Set-Aside of Orders (NOV 2011) (15 U.S.C. 644(r)).
____ (19) 52.219-14, Limitations on Subcontracting (DEVIATION 2019-O00003)
____ (20) 52.219-16, Liquidated Damages—Subcon-tracting Plan (Jan 1999) (15 U.S.C. 637(d)(4)(F)(i)).
____ (21) 52.219-27, Notice of Service-Disabled Veteran-Owned Small Business Set-Aside (NOV 2011) (15 U.S.C. 657f).
____ (22) 52.219-28, Post Award Small Business Program Rerepresentation (July 2013) (15 U.S.C.
632(a)(2)).
____ (23) 52.219-29, Notice of Set-Aside for, or Sole Source Award to, Economically Disadvantaged Women-Owned Small Business Concerns (Dec 2015) (15 U.S.C. 637(m)).
____(24) 52.219-30, Notice of Set-Aside for, or Sole Source Award to, Women-Owned Small Business Concerns Eligible Under the Women-Owned Small Business Program (Dec 2015) (15 U.S.C. 637(m)).
X (25) 52.222-3, Convict Labor (June 2003) (E.O. 11755).
____(26) 52.222-19, Child Labor--Cooperation with Authorities and Remedies (Jan 2018) (E.O. 13126).
____ (27) 52.222-21, Prohibition of Segregated Facilities (Apr 2015).
X (28)(i) 52.222-26, Equal Opportunity (SEPT 2016) (E.O. 11246).
____ (ii) Alternate I (Feb 1999) of 52.222-26.
____ (29)(i) 52.222-35, Equal Opportunity for Veterans (OCT 2015)(38 U.S.C. 4212).
____ (ii) Alternate I (July 2014) of 52.222-35.
____ (30)(i) 52.222-36, Equal Opportunity for Workers with Disabilities (JUL 2014) (29 U.S.C. 793).
____ (ii) Alternate I (July 2014) of 52.222-36.
____ (31) 52.222-37, Employment Reports on Veterans (FEB 2016) (38 U.S.C. 4212).
____ (32) 52.222-40, Notification of Employee Rights Under the National Labor Relations Act (Dec 2010) (E.O. 13496).
X (33)(i) 52.222-50, Combating Trafficking in Persons (March 2, 2015) (22 U.S.C. chapter 78 and E.O.
13627).
____ (ii) Alternate I (March 2, 2015) of 52.222-50 (22 U.S.C. chapter 78 and E.O. 13627).
____ (34) 52.222-54, Employment Eligibility Verification (Oct 2015). (E. O. 12989). (Not applicable to the acquisition of commercially available off-the-shelf items or certain other types of commercial items as prescribed in 22.1803.)
____ (35)(i) 52.223-9, Estimate of Percentage of Recovered Material Content for EPA–Designated Items (May 2008) (42 U.S.C. 6962(c)(3)(A)(ii)). (Not applicable to the acquisition of commercially available off-the-shelf items.)
____ (ii) Alternate I (May 2008) of 52.223-9 (42 U.S.C. 6962(i)(2)(C)). (Not applicable to the acquisition of commercially available off-the-shelf items.)
____ (36) 52.223-11, Ozone-Depleting Substances and High Global Warming Potential Hydrofluorocarbons (June, 2016) (E.O. 13693).
____ (37) 52.223-12, Maintenance, Service, Repair, or Disposal of Refrigeration Equipment and Air Conditioners (June, 2016) (E.O. 13693).
____ (38) (i) 52.223-13, Acquisition of EPEAT® Registered Imaging Equipment (Jun 2014) (E.O.s 13423 and 13514).
____ (ii) Alternate I (OCT 2015) of 52.223-13.
____ (39)(i) 52.223-14, Acquisition of EPEAT® Registered Televisions (Jun 2014) (E.O.s 13423 and 13514).
____ (ii) Alternate I (Jun 2014) of 52.223-14.
____ (40) 52.223-15, Energy Efficiency in Energy-Consuming Products (Dec 2007) (42 U.S.C. 8259b).
____ (41)(i) 52.223-16, Acquisition of EPEAT[supreg]-Registered Personal Computer Products (OCT 2015) (E.O.s 13423 and 13514).
____ (ii) Alternate I (Jun 2014) of 52.223-16.
X (42) 52.223-18, Encouraging Contractor Policies to Ban Text Messaging While Driving (Aug 2011) (E.O.
13513).
____ (43) 52.223-20, Aerosols (June, 2016) (E.O. 13693).
____ (44) 52.223-21, Foams (June, 2016) (E.O. 13693).
____ (45)(i) 52.224-3, Privacy Training (JAN 2017) (5 U.S.C. 552a).
____ (ii) Alternate I (JAN 2017) of 52.224-3.
____ (46) 52.225-1, Buy American--Supplies (May 2014) (41 U.S.C. chapter 83).
____ (47) (i) 52.225-3, Buy…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.