A2-03
DETAIL NO.
NORTH ARROW
DEMO MARK
DRAWING NO.
SHEET NO.
1 View Name 1/8" = 1'-0"A1-01
A 11'-0"
SHEET NUMBERING LEGEND
DISCIPLINE
G GENERAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
Q EQUIPMENT
P PLUMBING
M MECHANICAL
E ELECTRICAL
FP FIRE PROTECTION
X MISCELLANEOUS
PAGE NUMBERSECTION
0 DEMOLITION / GENERAL
1 PLANS
2 EXTERIOR ELEVATIONS
3 BUILDING / WALL SECTIONS
4 ELARGED PLANS, CASEWORK,
INTERIOR ELEVATIONS &
RELATED DETAILS
5 DETAILS
6 WINDOW & DOOR SCHEDULES
7 FINISH PLAN & SCHEDULES
8 VERTICAL CIRCULATION
9 BID ALTERNATES
A1-01
SYMBOL LEGEND
W1
B1
EHD
SCALE
DRAWING NAME
SHEET NO.
SECTION MARK
Room name
101A ROOM NAME/NUMBER
DOOR MARK
WINDOW MARK
CASEWORK MARK
EQUIPMENT MARK
REVISION AREA / NUMBER
CEILING TYPE / HEIGHT
WALL MARK
ACCESSORIES MARK
ELEVATION VALUE
REFERENCE
DESCRIPTION
15' - 4"
AFF
A2-03
SHEET NO.
DETAIL NO.
A2-03 2
A2-03 CALLOUT DETAIL
SHEET NO.
DETAIL NO.
EXTERIOR ELEVATION MARK
INTERIOR ELEVATION MARK
SHEET NO.
DETAIL NO.
EGRESS CALCULATION MARK
CONTROL / ELEVATION MARK
DOOR MARK
REQUIRED WIDTH
ANTICIPATED EGRESS LOAD
MAXIMUM
EGRESS LOAD
EGRESS WIDTH
Door 105 150A 30"
180M 36"
S4A
@ AT
AB AREA DRAIN
ACC ACCENT COLOR
ACT ACOUSTICAL CEILING TILE
ACOUS ACOUSTIC
ACW ACOUSTICAL WALL PANELS
ADJ ADJUSTABLE
AE APPROVED EQUAL
AFF ABOVE FINISH FLOOR
AFL ATHLETIC FLOORING
AHU AIR HANDLING UNIT
ALB ALUMINUM BASE
ALT ALUMINUM TILE
ALUM ALUMINUM
ANOD ANODIZED
ANSI AMERICAN NATIONAL
STANDARDS INSTITUTE
ATTEN ATTENUATION
AWP ACRYLIC WALL PANELS
BBT BIOBASED TILE
BF BLOCK FILL
BFC BROOMED FINISHED
CONCRETE
BL BLINDS
BLDG BUILDING
BLKG BLOCKING
BOT BOTTOM
BFG BULLET PROOF GLASS
CB# CATCH BASIN
CEM CEMENTIOUS SIDING
CF CORK FLOORING
CFCI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CFT CERAMIC FLOOR TILE
CG CURVED CEILING GRID
CI CAST IRON
CI# CURB INLET
CJ CONTROL JOINT
CLG CEILING
CL CENTERLINE
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONSTR CONSTRUCTION
CONTR CONTRACTOR
CORR CORRUGATED
CPT CARPET
CPTT CARPET TILE
CTB CERAMIC TILE BASE
CRC COLD ROLLED CHANNEL
CRF CORK RUBBER FLOORING
CS COUNTERSUNK
CWT CERAMIC WALL TILE
DET DETAIL
DEPT DRY FOG PAINT
DIA DIAMETER
DISP DISPENSER
DN DOWN
DP DEEP
DR DOOR
DS DOWNSPOUT
E/W EACH WAY
EDG EDGE BANDING
EES EMERGENCY EYE WASH AND
SHOWER
EFC EPOXY FLOOR COATING
EIFS EXTERIOR INSULATION
FINISH SYSTEM
EIP EXISTING IRON PIPE
ELEV ELEVATION
EJ EXPANSION JOINT
EN ENAMEL
EPT HIGH PERFORMANCE
EPOXY PAINT
EQ EQUAL
EST EXISTING
EXT EXTERIOR
EXP EXPOSED CEILING
EWC ELECTRIC WATER COOLER
FC FIRECODE
FD FLOOR DRAIN
FEB FIRE EXSTINGUISHER
BRACKET
FEC FIRE EXSTINGUISHER
CABINET
FF FINISH FLOOR
FH FIRE HYDRANT
FLU FLOURESCENT
FOF FACE OF FRAME
FOM FACE OF MASONRY
FOW FACE OF WALL
FTG FOOTING
GC GENERAL CONTRACTOR
GCT GRANITE COUNTERTOP
GA GAGE
GALV GALVANIZED
GEN GENERATOR
GFT GRANITE FLOOR TILE
GL GLASS
GMT GLASS MOSAIC TILE
GT GROUT
GYP GYPSUM BOARD
HC HOLLOW CORE
HB HOSE BIB
HC HANDICAPP
HDWD HARDWOOD
HM HOLLOW METAL
HORZ HORIZONTAL
HR HOUR
ICF INFECTION CONTROL
FLOORING
ID INSIDE DIAMETER
INSTAL INSTALLATION
INSUL INSULATION
INT INTERIOR
INV INVERT
JB JOIST BEARING
JB# JUNCTION BOX
JT JOINT
L LONG
LFT LINOLEUM FLOOR TILE
LP LIGHT POLE
LST LINOLEUM SHEET
FLOORING
LVT LUXURY VINYL TILE
MATL MATERIAL
MAX MAXIMUM
MC METAL CANOPY
MCT METAL CEILING TILE
MB MASONRY - BRICK
MECH MECHANICAL
MFR MANUFACTURER
MFT MARBLE FLOOR TILE
MIN MINIMUM
MO MASONRY OPENING
MTB MARBLE TILE BASE
MTD MOUNTED
MTL METAL
MWM METAL WALK-OFF MAT
MWT MARBLE WALL TILE
NIC NOT IN CONTRACT
NOM NORMAL
OC ON CENTER
OD OUTSIDE DIAMETER
OFOI OWNER FURNISHED,
OWNER INSTALLED
OFCI OWNER FURNISHED,
CONTRACTOR INSTALLED
OPP OPPOSITE
OZ OUNCE
P-LAM PLASTIC LAMINATE
P-LAM WD PLASTIC LAMINATE
WOOD DOORS
PC POLISHED CONCRETE
PERF PERFORATED
PFT PORCELAIN FLOOR TILE
PIV POST INDICATOR VALVE
PL PLATE
PLYWD PLYWOOD
PNT PAINT
PP POWER POLE
PR PAIR
PTB PORCELAIN TILE BASE
PTD PAINTED
PTP PLASTIC TOILET
PARTITIONS
PWT PORCELAIN WALL TILE
PVC POLYVINYL CHLORIDE
QS QUARTZ SURFACE
QT QUARRY TILE
QZT QUARTZ TILE
R RADIUS
R&S ROD AND SHELF
RB RUBBER BASE
RBT RUBBER TILE
RCP REINFORCED CONCRETE
RD ROOF DRAIN
RDL ROOF DRAIN LEADER
RECEPT RECEPTACLE
RECYF RECYCLED FLOORING
REQD REQUIRED
RES RESILIENT
RM RUBBER MAT
ROW RIGHT OF WAY
RSF RESINOUS FLOORING
RTF RESILENT TILE FLOORING
SAT SPRAYED ACOUSTICAL
TREATMENT
SC SEALED CONCRETE
SCH SCHEDULE
SCW SOLID CORE WOOD
SDT STATIC DISSIPATIVE TILE
SF SQUARE FEET
SIM SIMILAR
SLS SOLID SURFACE
SP SPACES
SQ SQUARE
SS STAINLESS STEEL
SSC STAINED SEALED
CONCRETE
SRT SLIP RESISTANT TILE
ST STEEL
ST&R STAIR TREADS AND
RISERS
STD STANDARD
SUSP SUSPENDED
TC TERRA COTTA
T&G TONGUE AND
GROOVE
TCA TILE COUNCIL OF
AMERICA
TELE TELEPHONE
TEMP TEMPERED
TEXD TEXTURED
TFT TERRAZZO FLOOR
TILE
TOC TOP OF CURB
TOS TOP OF STEEL
TP TELEPHONE POLE
TVB TELEVISION
MOUNTING BRACKET
TYP TYPICAL
UL UNDERWRITERS
LABORATORY
U/L UTILITY/LIGHTS
UON UNLESS OTHERWISE
NOTED
VACT VINYL ACOUSTICAL
TILE
VB VAPOR BARRIER
VCT VINYL COMPOSITION
TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VWC VINYL WALL
COVERING
W/ WITH
WC WATER CLOSET
WD WOOD
WF WOOD FLOORING
WWF WELDED WIRE
FABRIC
WWM WELDED WIRE MESH
ABBREVIATIONS
MIN.
10' - 0"
'-0"
M
IN.
MIN.
10' - 0"
EXISTING STRUCTURES
FE
N
C E
10'-0" MIN. FIRE SEPARATION DISTANCE
REQUIRED WHEN COMBINED BUILDINGS
SF IS LESS THAN < 9,625 SF.
30'-0" MIN. FIRE SEPARATION DISTANCE
REQUIRED WHEN COMBINED BUILDINGS
SF IS GREATER THAN > 9,625 SF.
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
T 919 781 8582 F 919 781 3979 4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com
Th is d raw ing an d t he de sig n s ho wn is the pro pe rty of Sm ith Si nn ett
Ar ch ite ctu re, P.A . t he re pro du cti on or us e o f th is pro pe rty w ith ou t th e w ritt en co ns en t o f th e Ar ch ite ct is pro hib ite d.
An y in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub jec t to leg al ac tio n.
Al l co pie s o f th is d raw ing mu st be re tur ne d t o t he
Ar ch ite ct at co mp let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
IN
G
IS
FO
RM
AT
TE
D T
O
BE
PR
IN
TE
D
ON
A
" X
" S
HE
ET
C :\U se rs
\n iz ar .S
SA
\D oc um en ts
\2
N C
N G
P ol e Ba rn _n m ad do ur i.r vt
2/8 /20
2:
:23
P M
G0-01L
COVER SHEET
NM
2021005 7 FEB 2022
LP/RC
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
NC NATIONAL GUARD POLE BARN PROTOTYPE
LARGE POLE BARN
NC NATIONAL GUARD
LA
RG
E
PO
LE
B
AR
N
N C
N
AT
IO
N
AL
G
U
AR
D
NC
N
AT
IO
NA
L
GU
AR
D
PO
LE
B
AR
N
PR
OT
OT
YP
E
INDEX OF DRAWINGSDESIGN PROFESSIONALS
BID ALTERNATES
REGISTEREDARC
HI
TE
CT
UR
AL CORPORAT I ON
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
OWNER:
NORTH CAROLINA NATIONAL GUARD
1636 GOLD STAR DRIVE
RALEIGH, NC 27607
919.664.6354 (P)
POC: ROBYN BRYANT
robyn.s.bryant.mil@mail.mil
ARCHITECTURE:
SMITH SINNETT ARCHITECTURE
4600 LAKE BOONE TRAIL, SUITE 205
RALEIGH, NC 27607
919.781.8582 (P)
POC: ROBERT CARMAC, AIA
rcarmac@smithsinnett.com
STRUCTURAL:
ROSS LINDEN ENGINEERS PC
709 W JONES STREET
RALEIGH, NC 27603
919.832.5680 (O)
POC: BRIAN ROSS, PE
brian@rosslinden.com
1. Lessons Learned Comments
- Set and protect multiple benchmark elevations in protected areas before any work is started. Maintain these until the project is completed.
- Insure all materials have been recieved, inspected, and stored onsite prior to digging footers. Some materials may require special storage, i.e. conditioned, weather proof, or flat storage.
- Coordinate waste site for spoiled soil prior to construction. Construction dumpster also needed.
- Discuss layout and traffic flow with customer well in advance.
- Order pre-fabricated material when possible.
- Coordinate in-person meeting with supplying to sort out details of items requested.
- Order trusses early as they have long lead times.
ALTERNATE 1 - BACK & SIDE WALLS
SCO#20-22822-01A
SC
O
#2 0-
2-
A
ALTERNATE 2 - CONCRETE SLAB
STRUCTURAL - LARGE DESIGN
S1-01L STRUCTURAL PLANS - 5 BAY LARGE
S1-02L STRUCTURAL PLANS - 4 BAY LARGE
S1-03L STRUCTURAL PLANS - 3 BAY LARGE
S1-04L STRUCTURAL PLANS - 2 BAY LARGE
S2-01 STRUCTURAL NOTES AND DETAILS
S2-02 STRUCTURAL DETAILS - ALTERANTES
GENERAL - LARGE DESIGN
G0-01L COVER SHEET
G0-02 BUILDABLE AREAS MAP
G0-03L BUILDING CODE SUMMARY
G0-04 SPECIFICATIONS
G1-01L LIFE SAFETY PLAN
ARCHITECTURAL - LARGE DESIGN
A1-01L FLOOR PLAN - 5 BAY LARGE DESIGN
A1-02L FLOOR PLAN - 4 BAY LARGE DESIGN
A1-03L FLOOR PLAN - 3 BAY LARGE DESIGN
A1-04L FLOOR PLAN - 2 BAY LARGE DESIGN
A3-01 WALL SECTIONS & DETAILS
A9-01 ALTERNATE
CHOOSE A SHEET
BASED ON THE NUMBER
OF BAYS DESIRED
CHOOSE A SHEET
BASED ON THE NUMBER
OF BAYS DESIRED
GENRAL NOTES
BUILDINGS PLACEMENT
FINISH OPTIONS (SEE A1-01)
NOTES: -BASIS OF DESIGN FOR COLOR SELECTION
-ROOF PANEL: PETERSON COMPANY OR EQUAL
COLOR SELECTION: ETUC FINAL COLOR
SELECTION APPROVAL BY:
CFMO FINAL COLOR
SELECTION APPROVAL BY:
signature signature
NOTE: COLORS SHALL BE SELECTED TO MATCH EXISTING. CONFIRM WITH CFMO PRIOR TO FINAL COLOR SELECTION. FINISH OPTIONS LISTED BELOW ARE FOR BASIC COLOR PALETTE COORDINATION.
MATCHING OF EXISTING BUILDING SHALL TAKE PRIORITY OVER LISTED FINISH OPTIONS.
MATCH ROOF COLOR
MATCH ROOF COLOR
STATUS BRONZE (SW 7034)
TONY TAUPE (SW 7038)
OXFORD BROWN, SOLID STAIN, PPG, SOL-058
GUTTERS & DOWNSPOUTS
TRIM + FASCIA + SOFFITS COLOR
ROOFING + FLASHING COLOR
GABLES + WALLS COLOR
POST + POLES COLOR
DESIGN DECISION APPROVAL
T 919 781 8582 F 919 781 3979
4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
Th is d raw ing an d t he de sig n s ho wn rty of Sm ith Si nn ett
Ar ch ite he re pro du cti on or us e o f th is pro pe rty w ith ou t th e w ritt en co ns en t o f th e Ar ch ite ct is pro hib ite d.
An y in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub ac tio n.
Al l co pie s o f th is d be re tur ne d t o t he
Ar ch ite ct let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
IN
G
IS
FO
RM
AT
TE
D T
O
BE
PR
IN
TE
D
ON
A
" X
" S
HE
ET
C :\U se rs
\n iz ar .S
SA
\D oc um en ts
\2
N C
N G
P ol e Ba rn _n m ad do ur i.r vt
2/8 /20
2:
:30
P M
G0-02
BUILDABLE AREAS
MAP
2021005 7 FEB 2022
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
NM
LP/RC
NC
N
AT
IO
NA
L
GU
AR
D
PO
LE
B
AR
N
PR
OT
OT
YP
E
LA
RG
E
PO
LE
B
AR
N N
C N
AT
IO
N
AL
G U
AR
D
REGISTEREDARC
HI
TE
CT
UR
AL CORPORAT I ON
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
BUILDABLE AREAS IN NORTH CAROLINA
PER NC BUILDING CODE 2018
NON-BUILDABLE
AREA
NON-BUILDABLE
AREA
NON-BUILDABLE
AREA
NON-BUILDABLE
AREA
NOTE:
THE FOLLOWING COUNTIES, IN WHOLE OR PART,
ARE LOCATED WITHIN THE CS SNOW REGIONS
AND/OR SPECIAL WIND REGIONS: RUTHERFORD,
MCDOWELL, BURKE, AVERY, CALDWELL,
WILKES.
FURTHER SITE SPECIFIC ANALYSIS MAY BE
REQUIRED.
LOCATIONS LIST:
SC
O
#2 0-
2-
A
BUILDABLE SITES NON-BUILDABLE SITES ( ADDITIONAL DESIGN REQUIRED FOR THESE LOCATIONS )
• Albemarle
• Asheboro
• Badin
• Belmont
• Benson
• Beulaville
• Burlington
• Butner
• Camp Butner
• Charlotte
• Clinton
• Concord
• Dunn
• Durham
• Edenton
• Elizabeth City
• Elizabethtown
• Farmville
• Fayetteville
• Forest City
• Fort Bragg
• Fremont
• Gastonia
• Goldsboro
• Greensboro
• Greenville
• Hickory
• High Point
• Kings Mountain
• Kinston
• Laurinburg
• No Modifications Necessary, Reviewed 07/23/21
• Lenoir
• Lexington
• Lincolnton
• Louisburg
• Marion
• McLeansville
• Mocksville
• Monroe
• Mooresville
• Morganton
• Morrisville
• Mount Olive
• Nashville
• New London
• Newton
• Oxford
• Parkton
• Raeford
• Raleigh
• Roanoke Rapids
• Rockingham
• Rocky Mount (future)
• Roseboro
• Saint Pauls
• Salemburg
• Salisbury
• Sanford
• Scotland Neck
• Siler City
• Smithfield
• Snow Hill
• Southern Pines
• Statesville
• Taylorsville
• Thomasville
• Wadesboro
• Washington
• Williamston
• Windsor
• Winterville
• Woodland
• Youngsville
• Asheville
• Boone
• East Flat Rock
• Elkin
• Fair Bluff
• Fort Fisher
• Franklin
• Hamlet
• Jacksonville
• Jefferson
• Lumberton
• Morehead City
• Mount Airy
• New Bern
• North Wilkesboro
• Red Springs
• Reidsville
• Roxboro
• Shallotte
• Sylva
• Wilmington Carolina Beach Road
• Wilmington New Hanover
• Whiteville
4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
Th is d raw ing an d t he de sig n s ho wn rty of Sm ith Si nn ett
Ar ch ite he re pro du cti on or us e o f th is pro pe rty w ith ou t th e w ritt en co ns en t o f th e Ar ch ite ct is pro hib ite d.
An y in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub ac tio n.
Al l co pie s o f th is d be re tur ne d t o t he
Ar ch ite ct let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
IN
G
IS
FO
RM
AT
TE
D T
O
BE
PR
IN
TE
D
ON
A
" X
" S
HE
ET
C :\U se rs
\n iz ar .S
SA
\D oc um en ts
\2
N C
N G
P ol e Ba rn _n m ad do ur i.r vt
2/8 /20
2:
:35
P M
G0-03L
BUILDING CODE
SUMMARY
2021005 7 FEB 2022
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
NM
LP/RC
NC
N
AT
IO
NA
L
GU
AR
D
PO
LE
B
AR
N
PR
OT
OT
YP
E
LA
RG
E
PO
LE
B
AR
N N
C N
AT
IO
N
AL
G U
AR
D
REGISTEREDARC
HI
TE
CT
UR
AL CORPORAT I ON
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
NC, LOCATIONS TO BE DETERMINATED VARIES
MAJ ROBYN BRAYANT
U
II
40'
0 HR
N/A
N/A
N/A
0 HR
0 HR
N/A
0 HR
0 HR
0 HR
N/A
N/A N/A N/A N/A N/A N/A
N/A N/A
2223 SF
3683 SF
2 BAY
N/A
(WORK AREAS)
(WORK AREAS)
(WORK AREAS)
G1-01
N/A
N/A
(919) 664.6116 robyn.s.bryant.mil@mail.mil
(“Other” should include firms and individuals such as truss, precast, pre-engineered, interior designers, etc.)
jurisdiction for additional procedures and requirements.
If special inspections are required, contact the local inspectionNoYesSpecial Inspections Required:
YesNoFlood Hazard Area:YesNoPrimary Fire District:
DryWetIIIIIIClassNoStandpipes:
NFPA 13DNFPA 13RNFPA 13PartialNoSprinklers:
B-VB-IIIB-IIB-I
A-VIVA-IIIA-IIA-IConstruction Type:
BASIC BUILDING DATA
Proposed:Current:OCCUPANCY CATEGORY (Table 1604.5):
PROPOSED OCCUPANCY(S) (Ch.3):RENOVATED: (date)
CURRENT OCCUPANCY(S) (Ch.3):CONSTRUCTED: (date) Alteration Level IIIChapter 14
Change of UseAlteration Level IIRepair(check all that apply) Historic PropertyAlteration Level IPrescriptive2018 NC EXISTING BUILDING CODE:
*Contact the local inspection jurisdiction for possiblitional procedures and requirements.
*onstructionChasedP*Shell/CoreTime Interior Completionsst1
AdditionNew Building2018 NC BUILDING CODE:
Other Retaining Walls >5' High Structural
Sprinkler Mechanical Plumbing Fire Alarm Electrical Civil Architectural
E-MAILTELEPHONE#LICENSE#NAMEFIRMDESIGNER
CONTACT:
StateCountyCityCode Enforcement Jurisdiction:
StatePrivateCity/CountyOwned By:
E-MailPhone #Owner/Authorized Agent:
Zip CodeAddress:
Name of Project:
(Reproduce the following data on the building plans sheet 1 or 2)
(EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)
BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS
2018 APPENDIX B
2018 NC Administrative Code and Policies
Gross Building Area Table
FLOOR N EW(SQ FT) TOTAL
2 BAY
3 BAY
4 BAY
5 BAY
2018 NC Administrative Code and Policies 2018 NC Administrative Code and Policies 2018 NC Administrative Code and Policies
2018 NC Administrative Code and Policies
ALLOWABLE AREA
Primary Occupancy Classification(s):
Assembly A-1 A-2 A-3 A-4 A-5 Business Educational Factory Hazardous Institutional
Mercantile Residential Storage
Parking Garage Utility and Miscellaneous
F-1 Moderate F-2 Low H-1 Detonate H-2 Deflagrate H-3 Combust H-4 Health H-5 HPM I-1 I-2 I-1 & I-2 Condition 1 2 I- I-4 I-3 Condition 1 2 3 4 5
R-1 R-2 R-3 R-4 S-1 Moderate S-2 Low High-piled
Open Enclosed Repair Garage
Accessory Occupancy Classification(s):
Incidental Uses (Table 509):
Special Uses (Chapter 4 - List Code Sections):
Special Provisions: (Chapter 5 - List Code Sections):
Mixed Occupancy: No Yes Separation: Hr. Exception:
Non-Separated Use (508.3) Separated Use (508.4) -See below for area calculations for each story, the area of the occupancy shall be such that the sum of the ratios of the actual floor area of each use divided by the allowable floor area for each use shall not exceed 1.
Frontage area increases from Section 506.2 are computed thus:1
a. Perimeter which fronts a public way or open space having 20 feet minimum width = ___________ (F)
b. Total Building Perimeter = ________ (P)
c. Ratio (F/P) = ___________(F/P)
d. W = Minimum width of public way = ________ (W)
Unlimited area applicable under conditions of Section 5.07 Maximum Building Area = total number of stories in the building xD (maximum 3 stories)
(506.2).
The maximum area of open parking garages must comply with Table 406.5.4 . The maximum area of air traffic control towers must comply with Table 412.3.1 Frontage increase is based on the unsprinklered area value in Table 506.2.
Actual Area of Occupancy A + Actual Area of Occupancy B Allowable Area of Occupancy A Allowable Area of Occupancy B
<1
1.00<
1,5 2,3
STORY
NO.
DESCRIPTION AND
USE
(A)
BLDG AREA PER
STORY (ACTUAL)
TABLE506.2
AREA
AREA FOR FRONTAGE
INCREASE
(D)
ALLOWABLE AREA PER
STORY OR UNLIMITED
FIRE PROTECTION REQUIREMENTS
Structural Frame, including columns, girders, trusses Bearing Walls
Exterior North East West South
Interior Nonbearing Walls and Partitions
Exterior walls North East West South
Interior walls and partitions
Floor Construction Including supporting beams and joists
Floor Ceiling Assembly Columns Supporting Floors
Roof Construction, including supporting beams and joists Roof Ceiling Assembly Columns Supporting Roof
Shaft Enclosures- Exit Shaft Enclosures- Other
Sleeping Unit Separation Incidental Use Separation
* Indicate section number permitting reduction
Corridor Separation Occupancy/Fire Barrier Separation Party/Fire Wall Separation Smoke Barrier Separation
Smoke Partition Tenant/Dwelling Unit/
Building Height in Feet (Table 504.3)
Building Height in Stories (Table 504.4)
1 Provide code reference if the “Shown on Plans” quantity is not based on Table 504.3 or 504.4.
ALLOWABLE SHOWN ON PLANS CODE REFERENCE
ALLOWABLE HEIGHT
BUILDING ELEMENT FIRE
SEPARATION
DISTANCE
(FEET)
RATING DETAIL#
AND
SHEET#
DESIGN#
FOR
RATED
ASSEMBLY
SHEET# FOR
RATED
PENETRATION
SHEET#
FOR
RATED
JOINTS
REQ'D PROVIDED
(W/_________*
REDUCTION)
Fire and/or smoke rated wall locations (Chapter 7) Assumed and real property line locations (if not on the site plan) Exterior wall opening area with respect to distance to assumed property lines (705.8) Occupancy Use for each area as it relates to occupant load calculation (Table 1004.1.2) Occupant loads for each area Exit access travel distances (1017) Common path of travel distances (Tables 1006.2.1 & 1006.3.2(1)) Dead end lengths (1020.4) Clear exit widths for each exit door Maximum calculated occupant load capacity each exit door can accommodate based on egress width (1005.3) Actual occupant load for each exit door A separate schematic plan indicating where fire rated floor/ceiling and/or roof structure is provided for purposes of occupancy separation Location of doors with panic hardware (1010.1.10) Location of doors with delayed egress locks and the amount of delay (1010.1.9.7) Location of doors with electromagnetic egress locks (1010.1.10) Location of doors equipped with hold-open devices Location of emergency escape windows (1030) The square footage of each fire area (202) The square footage of each smoke compartment for Occupancy Classification I-2 (407.5) Note any code exceptions or table notes that may have been utilized regarding the items above
LIFE SAFETY PLAN REQUIREMENTS
Life Safety Plan Sheet #:
Emergency Lighting:
Exit Signs:
Fire Alarm:
Smoke Detection Systems:
Carbon Monoxide Detection:
LIFE SAFETY SYSTEM REQUIREMENTS
No Yes No Yes No Yes No Yes Partial No Yes
PERCENTAGE OF WALL OPENING CALCULATIONS
FIRE SEPARATION DISTANCE
(FEET) FROM PROPERTY LINES
DEGREE OF OPENINGS
PROTECTION
(TABLE 705.8)
ALLOWABLE AREA
ACTUAL SHOWN ON PLANS
2018 NC Administrative Code and Policies
ENERGY SUMMARY
ENERGY REQUIREMENTS:
Existing building envelope complies with code:
Exempt Building:
Climate Zone:
Method of Compliance:
THERMAL ENVELOPE
Roof/ceiling Assembly
Exterior Walls
Walls below grade
Floors over unconditioned space
Floors slab on grade
The following data shall be considered minimum and any special attribute required to meet the energy code shall also be provided. Each Designer shall furnish the required portions of the project information for the plan data sheet.
If performance method, state the annual energy cost for the standard reference design vs annual energy cost for the proposed design.
(If checked the remainder of this section is not applicable.)
Provide code or statutory reference:
3A 4A 5A
Energy Code Performance Prescriptive ASHRAE 90.1 Performance Other
(Prescriptive method only) (each assembly)
Description of assembly:
U-Value of total assembly:
R-Value of insulation:
Skylights in each assembly:
U-Value of skylight:
total square footage of skylights in each assembly:
(each assembly) Description of assembly:
U-Value of total assembly:
R-Value of insulation:
Openings (windows or doors with glazing)
U-Value of assembly:
Solar heat gain coefficient:
projection factor:
Door R-Values:
(each assembly) Description of assembly:
U-Value of total assembly:
R-Value of total assembly:
(each assembly) Description of assembly:
U-Value of total assembly:
R-Value of total assembly:
Description of assembly:
U-Value of total assembly:
R-Value of insulation:
Horizontal/vertical requirement:
slab heated:
2018 APPENDIX B
BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS
STRUCTURAL DESIGN
(PROVIDE ON PROVIDE ON THE STRUCTURAL SHEETS IF APPLICABLE)
DESIGN LOADS:
Importance Factors:
Live Loads:
Ground Snow Load:
Wind Load:
SEISMIC DESIGN CATEGORY:
Occupancy Category Spectral Response Acceleration
Site Classification
Basic structural system
Analysis Procedure:
Architectural, Mechanical, Components anchored?
LATERAL DESIGN CONTROL:
SOIL BEARING CAPACITIES:
Wind (I ) Snow (I ) Seismic (I )
Roof Mezzanine psf Floor
Ultimate Wind Speed Exposure Category
A B C D Provide the following Seismic Design Parameters:
(Table 1604.5) I II III IV S S
(ASCE 7) A B C D E F
Data Source: Field Test Presumptive Historical Data
(check one) Bearing Wall Dual w/Special Moment Frame Building Frame Dual w/Intermediate R/C or Special Steel Moment Frame Inverted Pendulum
Simplified Equivalent Lateral Force Dynamic Yes No
Earthquake Wind
Field Test (provide copy of test report) psf Presumptive Bearing capacity psf Pile size, type, and capacity
W
S
E
S 1 psf psf mph (ASCE-7)
%g%g
2018 APPENDIX B
BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS
MECHANICAL DESIGN
(PROVIDE ON THE MECHANICAL SHEETS IF APPLICABLE)
MECHANICAL SUMMARY
MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT
Thermal Zone
Interior design conditions
Building heating load:
Building cooling load:
Mechanical Spacing Conditioning System
List equipment efficiencies:
winter dry bulb:
summer dry bulb:
winter dry bulb:
summer dry bulb:
relative humidity:
Unitary description of unit:
heating efficiency:
cooling efficiency:
size category of unit:
Boiler Size category. If oversized, state reason.:
Chiller Size category. If oversized, state reason.:
2018 APPENDIX B
BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS
ELECTRICAL DESIGN
(PROVIDE ON THE ELECTRICAL SHEETS IF APPLICABLE)
ELECTRICAL SUMMARY
ELECTRICAL SYSTEM AND EQUIPMENT
Method of Compliance:
Lighting schedule
Additional Efficiency Package Options (When using the 2018 NCECC; not required for ASHRAE 90.1)
Energy Code: Prescriptive Performance ASHRAE 90.1: Prescriptive Performance
(each fixture type) lamp type required in fixture number of lamps in fixture ballast type used in the fixture number of ballasts in fixture total wattage per fixture total interior wattage specified vs. allowed (whole building or space by space) total exterior wattage specified vs. allowed
C406.2 More Efficient HVAC Equipment Performance C406.3 Reduced Lighting Power Density C406.4 Enhanced Digital Lighting Controls C406.5 On-Site Renewable Energy C406.6 Dedicated Outdoor Air System C406.7 Reduced Energy Use in Service Water Heating
(B) (C)
Performance (specify source) Prescriptive psf
2018 NC Administrative Code and Policies
ACCESSIBLE DWELLING UNITS
ACCESSIBLE PARKING
PLUMBING FIXTURE REQUIREMENTS
(TABLE 2902.1)
SPECIAL APPROVALS
(SECTION 1107)
(SECTION 1106)
OTAL
NITS
ACCESSIBLE
NITS
EQUIRED
CCESSIBLE
NITS
ROVIDED
YPE
NITS
EQUIRED
YPE
NITS
ROVIDED
YPE
NITS
EQUIRED
YPE
NITS
ROVIDED
TOTAL
ACCESSIBLE NITS
PROVIDED
LOT OR PARKING
AREA
TOTAL OF PARKING SPACES OF ACCESSIBLE SPACES PROVIDED TOTAL
ACCESSIBLE
PROVIDED
REQUIRED PROVIDED REGULAR WITH
ACCESSAISLE
VAN SPACES WITH
ACCESS
AISLE
ACCESS
AISLE
TOTAL
USE WATERCLOSETS URINALS LAVATORIES SHOWERS
/TUBS
DRINKING FOUNTAINS
M F UNI MALE FEMALE UNISEX REGULAR ACCESSIBLE
T U U
R
A U
P
T A U
R
T A U
P
T B U
R
T B U
P U
5' 132” 8'
(Local Jurisdiction, Department of Insurance, OSC, DPI, DHHS, etc., describe below)Special approval:
Standpipe
ROBERT CARMAC, SMITH SINNETT ARCHITECTURE
SMITH SINNETT ROBERT CARMAC
N/A
NC10612 919 781.8582 rcarmac@smithsinnett.com
Renovation
ROSS LINDEN ENGINEERS BRIAN ROSS NC25539 919 832 5680 brian@rosslinden.com
e. Percent of frontage increase I = 100[F/P - 0.25] x W/30 = _________(%)f
1493 SF
2953 SF
2223 SF
3683 SF
1493 SF
2953 SF
3 BAY
4 BAY
5 BAY
1 1,493 2,223 2,953 3,683
5,500 5,500 5,500 5,500
4,125 9,625 4,125 4,125 4,125
9,625 9,625 9,625
184,174,200,226
25' - 6"
>30'
N/A
VARIES
184,174,200,226
NORTH CAROLINA NATIONAL GUARD POLE BARNS
2 BAY 3 BAY 4 BAY 5 BAY
1.0 1.0 1.0
1.0 1.0 1.0
1.0 1.0 1.0
1.0 1.0 1.0
B
0.35 0.12
SC
O
#2 0-
2-
A
NOT
APPLICABLE
NOT
APPLICABLE
NOT
APPLICABLE
NOTE: OWNER TO CONFIRM. ADDITIONAL DESIGN
REQUIRED IF LOCATED IN A FLOOD HAZARD AREA
4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
Th is d raw ing an d t he de sig n s ho wn rty of Sm ith Si nn ett
Ar ch ite he re pro du cti on or us e o f th is pro pe rty w ith ou t th e w ritt en co ns en t o f th e Ar ch ite ct is pro hib ite d.
An y in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub ac tio n.
Al l co pie s o f th is d be re tur ne d t o t he
Ar ch ite ct let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
IN
G
IS
FO
RM
AT
TE
D T
O
BE
PR
IN
TE
D
ON
A
" X
" S
HE
ET
C :\U se rs
\n iz ar .S
SA
\D oc um en ts
\2
N C
N G
P ol e Ba rn _n m ad do ur i.r vt
2/8 /20
2:
:41
P M
G0-04
SPECIFICATIONS
2021005 7 FEB 2022
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
NM
LP/RC
NC
N
AT
IO
NA
L
GU
AR
D
PO
LE
B
AR
N
PR
OT
OT
YP
E
LA
RG
E
PO
LE
B
AR
N N
C N
AT
IO
N
AL
G U
AR
D
REGISTEREDARC
HI
TE
CT
UR
AL CORPORAT I ON
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
SC
O
#2 0-
2-
A
055000 METAL FABRICATIONS
This Section includes the following: Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, products specified.
Metal Surfaces, General: Provide materials with smooth, flat surfaces without blemishes.
Ferrous Metals: Steel Pipe: ASTM A 53/A 53M, standard weight (Schedule 40), unless another weight is indicated or required by structural loads.
Cast Iron: ASTM A 48/A 48M, Class 30, unless another class is indicated or required by structural loads.
General: Type 304 stainless-steel fasteners for exterior use and zinc-plated fasteners with coating complying with ASTM B 633, Class Fe/Zn 5, at exterior walls. Provide stainless-steel fasteners for fastening aluminum. Select fasteners for type, grade, and class required.
MISCELLANEOUS MATERIALS
Zinc-Rich Primer: Complying with SSPC-Paint 20 or SSPC-Paint 29 and compatible with topcoat.
Available Products:Benjamin Moore & Co.; Epoxy Zinc-Rich Primer CM18/19.
ICI Devoe Coatings; Catha-Coat 313.
PPG Architectural Finishes, Inc.; Aquapon Zinc-Rich Primer 97-670.
Sherwin-Williams Company (The); Corothane I GalvaPac Zinc Primer.
FINISHES: Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes. Finish metal fabrications after assembly.
Steel Finishes: Hot-dip galvanize items as indicated to comply with ASTM A 123/A 123M or ASTM A 153/A 153M as applicable.
INSTALLATION
Cast iron downspout boots: Install on building per manufacture's recommendations with stainless steel fasteners as recommended.
Downspout boots are to be furnished without finish. They are not to be painted.
Available Products:Neenah foundry Co., J.R. Hoe and Sons, Piedmont Pipe Construction Inc., or Barry Pattern & Foundry Company, Inc.
Drainage Piping: For attachment to downspout boots. 4” Black Corrugated HDPE Drain Pipe Solid.
Install at each downspout boot.
Splash Block: Premanufactured concrete splash block. Provide in lieu of Downspout boot and corrugated pipe on a site by site basis based on site related conditions.
061000 ROUGH CARPENTRY
DIMENSION LUMBER: Provide dimension lumber of grades indicated according to the ALSC National Grading Rule (NGR) provisions of the inspection agency indicated.
MISCELLANEOUS FRAMING: Grade: No. 2. Species: Southern pine
BOARDS: Where boards will be exposed in the finished work, provide the following:
Moisture Content: 19 percent maximum, Species and Grade: Southern pine, C Finish per SPIB rules.
Concealed Boards: Where boards will be concealed by other work, provide lumber with 19 percent maximum moisture content and of following species and grade: Species and Grade: Mixed southern pine, No. 2 per SPIB rules.
074100 METAL ROOF PANELS AND METAL SOFFIT PANELS
CORRUGATED METAL ROOF PANEL SYSTEM: Panel materials: 24 gauge, Grade 40 (40 ksi yield strength) structural steel ASTM A366. Panel shall be corrugated and have ribs that are specific to the profile.
Texture: panels shall be smooth.
Finish: Refer to manufacturer’s standard samples to determine final finish. All panels shall receive a factory-applied oil-coating prior to corrugating. Final finish is determined by time and geographic location. Panels do not come pre-weathered.
Fastener: Panels shall be attached to the substrate with exposed screws. All screws shall be galvanized and color coated to match panel color. They shall have a combination EPDM gasket and a painted flange to match the patina of the roofing material. Screws for panel to girt/purlins shall be of the #9-16, sufficient length to penetrate the supporting member by 1”, and fastened 24” o.c. All fasteners shall be applied in accordance with manufacturer’s recommendations.
Screws for flashings and sidelaps shall be #14 x 7/8” sheet metal stitch screws.
All accessories, flashings, and sidelaps shall be fastened 12” o.c.
Fabrication: Panels are lappable. It is recommended that individual steel roof panels not exceed 32’ in length for thermal movement reasons. Panels shall be roll-formed on a stationary industrial type rolling mill to gradually shape the sheet metal. Portable rollformers, rented or owned by the installer, are not acceptable. Fabricate flashings from the same material as the roof system.
Uplift Rating: See G0-03 structural design loads.
Structural Performance: Provide metal roof panel assemblies capable of withstanding the effects of gravity loads and the following loads and stresses within limits and under conditions indicated, based on testing according to ASTM E 1592 Wind Loads: Uniform pressure of See G0-03 structural design loads, acting inward or outward.
Snow Loads: See G0-03 structural design loads.
Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace metal roof panel assemblies that fail in materials or workmanship within specified warranty period.
Warranty Period: Two years from date of Final Completion.
Special Warranty on Panel Finishes: Manufacturer's standard form in which manufacturer agrees to repair finish or replace metal roof panels that show evidence of deterioration of factory-applied finishes within specified warranty period. Finish Warranty Period: 10 years from date of Final Completion.
UNDERLAYMENT MATERIALS: Air and Water Barrier: Self-Adhering, High-Temperature Sheet: 30 to 40 mils thick minimum, consisting of slip-resisting, polyethylene-film top surface laminated to layer of butyl or SBS-modified asphalt adhesive, with release-paper backing; cold applied. Provide primer when recommended by underlayment manufacturer.
Slip Sheet: Manufacturer's recommended slip sheet, of type required for application.
ACCESSORIES
Roof Panel Accessories: Provide components approved by roof panel manufacturer and as required for a complete metal roof panel assembly including trim, copings, fasciae, corner units, ridge closures, clips, flashings, sealants, gaskets, fillers, closure strips, and similar items. Match material and finish of metal roof panels unless otherwise indicated.
Ridge Closure assembly: Ridge assembly shall be designed to provide proper ventilation to prevent condensation and also prevent water penetration during the specified wind conditions. The ridge assembly shall be designed and installed to allow roof panels to ventilate and to expand and contract length-wise as the temperature of the roof panel changes. Minimum 12” of metal cap on each side of Ridge.
Vent: Provide premanufactured continuous 2” soffit or fascia vent Closures: Provide closures at eaves and ridges, fabricated of same metal as metal roof panels.
Closure Strips: Closed-cell, expanded, cellular, rubber or crosslinked, polyolefin-foam or closed-cell laminated polyethylene; minimum 1-inch- (25-mm-) thick, flexible closure strips; cut or pre-molded to match metal roof panel profile. Provide closure strips where indicated or necessary to ensure weathertight construction.
Backing Plates: Provide metal backing plates at panel end splices, fabricated from material recommended by manufacturer.
Flashing and Trim: Formed from same material as roof panels, pre-painted with coil coating, minimum
0.018 inch thick. Provide flashing and trim as required to seal against weather and to provide finished appearance. Locations include, but are not limited to, eaves, rakes, corners, bases, framed openings, ridges, fasciae, and fillers. Finish flashing and trim with same finish system as adjacent metal roof panels.
Gutters: 6” Formed from same material roof panels. Match profile of gable trim, complete with end pieces, outlet tubes, and other special pieces as required. Fabricate in minimum 96-inch long sections, of size and metal thickness according to SMACNA's "Architectural Sheet Metal Manual."
Furnish gutter supports spaced a maximum of 36 inches o.c., fabricated from same metal as gutters.
Provide wire ball strainers of compatible metal at outlets. Finish gutters to match metal roof panels.
Gutters shall slope a minimum 1/16” per 1’ to the downspout.
Downspouts: 4” Formed from same material as roof panels. Fabricate in 10-foot long sections, complete with formed elbows and offsets, of size and metal thickness according to SMACNA's "Architectural Sheet Metal Manual". Finish downspouts to match gutters.
FABRICATION: Fabricate and finish metal roof panels and accessories at the factory to greatest extent possible, by manufacturer's standard procedures and processes and as necessary to fulfill indicated performance requirements. Comply with indicated profiles and with dimensional and structural requirements.
Fabricate metal roof panel side laps with factory-installed captive gaskets or separator strips that provide a tight seal and prevent metal-to-metal contact, in a manner that will seal weathertight and minimize noise from movements within panel assembly.
Sheet Metal Accessories: Fabricate flashing and trim to comply with recommendations in SMACNA's "Architectural Sheet Metal Manual" that apply to the design, dimensions, metal, and other characteristics of item indicated
EXECUTION
UNDERLAYMENT INSTALLATION: Air and Water Barrier: Apply over entire roof substrate, in shingle fashion to shed water, and with lapped joints of not less than 6 inches staggered 24 inches between courses. Extend underlayment into gutter trough.
METAL ROOF PANEL INSTALLATION: Metal Roof Panels: Fasten metal roof panels to supports with manufacturer approved fasteners matching color of metal roof with neoprene washers at each location and spacing recommended by manufacturer.
General: Comply with manufacturers' instructions and recommendations for installation, as applicable to project conditions and supporting substrates. Anchor panels and other components of the work securely in place, with provisions for thermal and structural movement. Install panels plumb, level, and straight with the ribs parallel, conforming to the design as indicated. Install panel system so it is watertight, without waves, warps, buckles or distortions, and allow for thermal movement considerations. Apply sealant tape or caulking as necessary at flashing and panel joints to prevent water penetration. Installation Tolerances: Shim and align panel units within installed tolerance of 1/8 inch in 20'-0" on level/plumb/slope and location/line as indicated, and within 1/16-inch offset of adjoining faces and of alignment of matching profiles.
ACCESSORY INSTALLATION
General: Install accessories with positive anchorage to building and weathertight mounting and provide for thermal expansion. Coordinate installation with flashings and other components.
Install components required for a complete metal roof panel assembly including trim, copings, ridge closures, seam covers, flashings, sealants, gaskets, fillers, closure strips, and similar items.
Flashing and Trim: Comply with performance requirements, manufacturer's written installation instructions, and SMACNA's "Architectural Sheet Metal Manual." Provide concealed fasteners where possible, and set units true to line and level as indicated. Install work with laps, joints, and seams that will be permanently watertight and weather resistant.
Provide cast iron boots at base of downspouts with splash blocks to direct water away from the building or into a subsurface drainage pipe daylighting remote from the building.
Remove temporary protective coverings and strippable films, if any, as metal roof panels are installed unless otherwise indicated in manufacturer's written installation instructions. On completion of metal roof panel installation, clean finished surfaces as recommended by metal roof panel manufacturer.
Maintain in a clean condition during construction.
SECTION 074600 - SIDING
GENERAL
This Section includes the following:
1.Fiber-cement siding.
2.Fiber-cement soffit.
QUALITY ASSURANCE
Source Limitations for Siding and Soffit: Obtain each type, color, texture, and pattern of siding and soffit, including related accessories, through one source from a single manufacturer.
PROJECT CONDITIONS
Weather Limitations: Proceed with siding installation only if substrate is completely dry and if existing and forecasted weather conditions permit siding to be installed according to manufacturer's written instructions.
SEQUENCING
Coordinate installation with flashings and other adjoining construction to ensure proper sequencing.
WARRANTY
Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace siding that does not comply with requirements or that fails within specified warranty period. Failures include, but are not limited to, cracking, deforming, fading, or otherwise deteriorating beyond normal weathering.
Fading is defined as loss of color, after cleaning with product recommended by manufacturer, of more than 4 Hunter color-difference units as measured according to ASTM D 2244.
Warranty Period: 25 years from date of Substantial Completion.
PRODUCTS
MANUFACTURERS
SIDING
Because of the variety of types and appearances available, selecting specific products is recommended.
Revise this Article to specify actual siding selected. Pattern selections are the most commonly available types; other styles are also available.
Fiber-Cement Siding: Siding made from fiber-cement board that does not contain asbestos fibers;
complies with ASTM C 1186, Type A, Grade II; is classified as noncombustible when tested according to ASTM E 136; and has a flame-spread index of 25 or less when tested according to ASTM E 84.
Basis-of-Design Product: James Hardie Inc. ; Hardiepanel® Vertical siding or a comparable product.
Manufacturers:
1. Cemplank, Inc.
2. CertainTeed Corp.
3. First manufacturer below makes only shingle-style siding.
4. GAF Materials Corporation.
5. MaxiTile, Inc.
Vertical Pattern: 48-inch- wide sheets with Smooth texture and trims 48 inches o.c.
Panel Pattern: 48-inch- wide sheets with smooth texture.
Insert other patterns, such as shingle pattern, if required.
Factory priming is offered as an option by manufacturers listed.
Factory Priming: Manufacturer's standard acrylic primer.
SOFFIT
Fiber-Cement Soffit: Panels made from fiber-cement board that does not contain asbestos fibers;
complies with ASTM C 1186, Type A, Grade II; is classified as noncombustible when tested according to ASTM E 136; and has a flame-spread index of 25 or less when tested according to ASTM E 84.
Basis-of-Design Product: James Hardie Inc.; Hardiesoffit® Panels or a comparable product.
Manufacturers:
Same manufacturers listed for fiber-cement siding.
If retaining last subparagraph above, delete first five subparagraphs below.
1. Cemplank, Inc.
2.CertainTeed Corp.
3.James Hardie Inc.
4.MaxiTile, Inc.
Pattern: 16-inch wide sheets with smooth texture.
Ventilation: Provide unperforated soffit, unless otherwise indicated.
Factory Priming: Manufacturer's standard acrylic primer.
ACCESSORIES
Siding Accessories: Provide starter strips, edge trim, corner cap, and other items as recommended by siding manufacturer for building configuration.
Provide accessories made from same material as adjacent siding, unless otherwise indicated.
Provide accessories matching color and texture of adjacent siding, unless otherwise indicated.
Retain one of four options in first paragraph below. If retaining first, indicate colors in a separate schedule.
Flashing:
Provide aluminum flashing.
Finish for Aluminum Flashing: Siliconized polyester coating, same color as siding.
Retain one of three options in first paragraph below. Silicones cannot generally be painted.
Multicomponent urethanes can be a problem if not properly mixed, but they cure faster than single-component urethanes.
Elastomeric Joint Sealant:
Single-component urethane or Single-component neutral-curing silicone joint sealant for Use NT (nontraffic) and for Uses M, G, A, and, as applicable to joint substrates indicated, O joint substrates.
Fasteners:
1.For fastening to wood, use siding nails or ribbed bugle-head screws of sufficient length to penetrate a minimum of 1 inch into substrate.
2.For fastening aluminum, use aluminum fasteners. Where fasteners will be exposed to view, use prefinished aluminum fasteners in color to match item being fastened.
3.For fastening fiber-cement siding, use hot-dip galvanized fasteners.
Where fasteners will be exposed to view, use prefinished aluminum fasteners in color to match item being fastened.
EXECUTION
EXAMINATION
Examine substrates for compliance with requirements for installation tolerances and other conditions affecting performance of siding. Proceed with installation only after unsatisfactory conditions have been corrected.
PREPARATION
Clean substrates of projections and substances detrimental to application.
INSTALLATION
General: Comply with siding manufacturer's written installation instructions applicable to products and applications indicated unless more stringent requirements apply. Center nails in elongated nailing slots without binding siding to allow for thermal movement. Overlap joints to shed water away from direction of prevailing wind.
ADJUSTING AND CLEANING
Remove damaged, improperly installed, or otherwise defective siding materials and replace with new materials complying with specified requirements.
Clean finished surfaces according to siding manufacturer's written instructions and maintain in a clean condition during construction.
46' - 10"
3670 SF
@ 200=
19 PERSONS
3670 SF
@200
46' - 10"
2941 SF
@ 200=
15 PERSONS
2941 SF
@200
46' - 10"
2213 SF
@ 200=
12 PERSONS
2213 SF
@200
46' - 10"
1484 SF
@ 200=
8 PERSONS
1484 SF
@200
LIFE SAFETY LEGEND
EXIT ACCESS TRAVEL DISTANCE
(PER NCBC 1017) MAXIMUM 300'
LOCATION OF FIRE EXTINGUISHER ON A BRACKETFEB
OCCUPANCY FACTOR PER CODE
4500 SF
@ 100 GROSS =
45 PERSONS
ACTUAL ROOM AREA
TOTAL OCCUPANTS PER ROOM PER CODE
LOCATION OF AUTOMATED
DEFIBRILLATOR CABINET
AEDAED
NOTE: ALTERNATES SHOWN FOR CLARITY
T 919 781 8582 F 919 781 3979
4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
Th is d raw ing an d t he de sig n s ho wn rty of Sm ith Si nn ett
Ar ch ite he re pro du cti on or us e o f th is pro pe rty w ith ou t th e w ritt en co ns en t o f th e Ar ch ite ct is pro hib ite d.
An y in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub ac tio n.
Al l co pie s o f th is d be re tur ne d t o t he
Ar ch ite ct let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
IN
G
IS
FO
RM
AT
TE
D T
O
BE
PR
IN
TE
D
ON
A
" X
" S
HE
ET
C :\U se rs
\n iz ar .S
SA
\D oc um en ts
\2
N C
N G
P ol e Ba rn _n m ad do ur i.r vt
2/8 /20
2:
:50
P M
G1-01L
LIFE SAFETY PLAN
2021005 7 FEB 2022
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
NM
LP/RC
NC
N
AT
IO
NA
L
GU
AR
D
PO
LE
B
AR
N
PR
OT
OT
YP
E
LA
RG
E
PO
LE
B
AR
N N
C N
AT
IO
N
AL
G U
AR
D
REGISTEREDARC
HI
TE
CT
UR
AL CORPORAT I ON
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
1/8" = 1'-0"G1-01L
1 LIFE SAFETY PLAN - LARGE 5 BAY
1/8" = 1'-0"G1-01L
2 LIFE SAFETY PLAN - LARGE 4 BAY
1/8" = 1'-0"G1-01L
3 LIFE SAFETY PLAN - LARGE 3 BAY
1/8" = 1'-0"G1-01L
4 LIFE SAFETY PLAN - LARGE 2 BAY
SC
O
#2 0-
2-
A
A1-01L
A1-01L
A1-01L
F.L5
E.L5
D.L5
C.L5
B.L5
A.L5
5.L51.L5
48' - 8"
' - 1
1"
' - 0
' - 0
' - 0
' - 1
1"
A1-01L
VEHICLE FOOTPRINT (WWSV)
A3-01
3.L5 2 A3-01
11' - 11" 12' - 0" 12' - 0" 11' - 11"
' - 8
PRE-FINISHED
ALUMINUM DOWNSPOUT
PRE-FINISHED
ALUMINUM DOWNSPOUT
PRE-FINISHED
ALUMINUM DOWNSPOUT
PRE-FINISHED
ALUMINUM DOWNSPOUT
4.L52.L5
10"x10" P.T. WOOD POST TYP.
REFER TO STRUCTURAL
DRAWINGS
DASHED LINE
INDICATES ROOF
OVERHANG ABOVE
6" LAYER OF COMPACTED
ABC STONE TYP.
NOTES
1. THE CONTRACTOR SHALL FIELD VERIFY THE DIMENSIONS, ELEVATIONS, AND OTHER REQUIREMENTS NECESSARY FOR
CONSTRUCTION.
2. NC NATIONAL GUARD TO COORDINATE CONTINUATION OF WORK OUTSIDE OF BUILDING.
3. DOWNSPOUTS TO BE TIED INTO UNDERGROUND PIPING IN COORDINATION WITH NATIONAL GUARD CIVIL DRAWINGS.
4. INSTALL ALL MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
5. CONCRETE CONTROL JOINTS SHALL BE AS SHOWN ON PLANS AND ELEVATIONS OR SPACED AT A MAXIMUM OF 15'-0" OC
6. REFER TO STRUCTUAL DRAWINGS FOR LOCATION OF REINFORCING, BEAMS, BRACING, ETC.
7. MAINTAIN POSITIVE FLOOR DRAINAGE TOWARD OPEN PERIMETER.
GRADE LEVEL
0"
BOTTOM OF BEAM
15' - 0"
F.L5E.L5D.L5C.L5B.L5A.L5
METAL ROOF
PREFINISHED ALUMINUM GUTTER
STAIN ALL POSTS AND EXTERIOR WOODWORK
CONTINUOUS TO INSIDE B.O. TRUSSWORK.
PRE-FINISHED ALUMINUM DOWNSPOUT
REFERENCE DETAIL
10x10 P.T POST. TYP.VEHICLE
FOOTPRINT
(WWSV) /3 A3-01
KNEE BRACE, REFER TO STRUCTURAL
DRAWINGS
GRADE LEVEL
0"
BOTTOM OF BEAM
15' - 0"
5.L5 1.L53.L5
18"x24" ALUMINUM
GABLE VENT WITH 50%
CLEAR AREA. INCLUDE
1/8" INSECT SCREEN
METAL ROOF
LAP FIBER CEMENT SIDING
COUNTERSINK BOLTS UNDER
FIBER CEMENT SIDING
IN BEAM ON GABLE ENDS
VEHICLE
FOOTPRINT
(WWSV)
4.L5 2.L5
KNEE BRACE, REFER TO
STRUCTURAL DRAWINGS
A3-01
TYP.
GRADE LEVEL
0"
BOTTOM OF BEAM
15' - 0"
5.L51.L5
VEHICLE
FOOTPRINT
(WWSV)
3.L5
18"x24" ALUMINUM
GABLE VENT WITH 50%
CLEAR AREA. INCLUDE
1/8" INSECT SCREEN
METAL ROOF
LAP FIBER CEMENT SIDING
COUNTERSINK BOLTS UNDER
FIBER CEMENT SIDING
IN BEAM ON GABLE ENDS
4.L52.L5
KNEE BRACE, REFER TO
STRUCTURAL DRAWINGS
A3-01
TYP.
GRADE LEVEL
0"
BOTTOM OF BEAM
15' - 0"
F.L5 E.L5 D.L5 C.L5 B.L5 A.L5
VEHICLE
FOOTPRINT
(WWSV
METAL ROOF
PREFINISHED ALUMINUM GUTTER
STAIN ALL POSTS AND EXTERIOR WOODWORK
CONTINUOUS TO INSIDE B.O. TRUSSWORK.
PRE-FINISHED ALUMINUM DOWNSPOUT
REFERENCE DETAIL
10x10 P.T POST. TYP.
/3 A3-01
KNEE BRACE, REFER TO STRUCTURAL
DRAWINGS
T 919 781 8582 F 919 781 3979
4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
Th is d raw ing an d t he de sig n s ho wn rty of Sm ith Si nn ett
Ar ch ite he re pro du cti on or us e o f th is pro pe rty w ith ou t th e w ritt en co ns en t o f th e Ar ch ite ct is pro hib ite d.
An y in frin ge me nt of the ow ne rsh ip rig hts wi ll b e s ub ac tio n.
Al l co pie s o f th is d be re tur ne d t o t he
Ar ch ite ct let ion of th e c on tra ct.
Sm ith
Si nn ett Ar ch ite ctu re, P.
A.
TH
IS
DR
AW
IN
G
IS
FO
RM
AT
TE
D T
O
BE
PR
IN
TE
D
ON
A
" X
" S
HE
ET
C :\U se rs
\n iz ar .S
SA
\D oc um en ts
\2
N C
N G
P ol e Ba rn _n m ad do ur i.r vt
2/8 /20
2:
:39
P M
A1-01L
FLOOR PLAN - 5
BAY LARGE DESIGN
2021005 7 FEB 2022
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
NM
LP/RC
NC
N
AT
IO
NA
L
GU
AR
D
PO
LE
B
AR
N
PR
OT
OT
YP
E
LA
RG
E
PO
LE
B
AR
N N
C N
AT
IO
N
AL
G U
AR
D
REGISTEREDARC
HI
TE
CT
UR
AL CORPORAT I ON
NORT
H
CA
RO
LI
NA
AR
CH
ITE
CTU
,PA
RA
LE
IG
H
CE
RT
. N
O.
RE
SIN
ET
T N
SMIHT
1/4" = 1'-0"A1-01L
1 FLOOR PLAN - LARGE DESIGN 5 BAY
1/8" = 1'-0"A1-01L
5 BUILDING ELEVATION EST
1/8" = 1'-0"A1-01L
4 BUILDING ELEVATION NORTH
1/8" = 1'-0"A1-01L
2 BUILDING ELEVATION SOUTH
1/8" = 1'-0"A1-01L
3 BUILDING ELEVATION WEST
SC
O
#2 0-
2-
A1-02L
A1-02L
A1-02L
E.4L
D.4L
C.4L
B.4L
A.4L
3.4L1.4L
11' - 11" 12' - 0" 12' - 0" 11' - 11"
' - 1
1"
' - 0
' - 0
' - 1 1"
2.4L 2 A3-01
A3-01
WATER WELL SUPPORT VEHICLE (WWSV) FOOTPRINT
' - 7
48' - 8" PRE-FINISHED
ALUMINUM DOWNSPOUT
PRE-FINISHED
ALUMINIUM DOWNSPOUT
PRE-FINISHED
ALUMINUM DOWNSPOUT
PRE-FINISHED
ALUMINUM DOWNSPOUT
2.L6 2.L7
DASHED LINE
INDICATES ROOF
OVERHANG ABOVE
10"x10" P.T. WOOD POST TYP.
REFER TO STRUCTURAL
DRAWINGS
6" LAYER OF COMPACTED
ABC STONE TYP.
NOTES
1. THE CONTRACTOR SHALL FIELD VERIFY THE DIMENSIONS, ELEVATIONS, AND OTHER REQUIREMENTS NECESSARY FOR
CONSTRUCTION.
2. NC NATIONAL GUARD TO COORDINATE CONTINUATION OF WORK OUTSIDE OF BUILDING.
3. DOWNSPOUTS TO BE TIED INTO UNDERGROUND PIPING IN COORDINATION WITH NATIONAL GUARD CIVIL DRAWINGS.
4. INSTALL ALL MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
5. CONCRETE CONTROL JOINTS SHALL BE AS SHOWN ON PLANS AND ELEVATIONS OR SPACED AT A MAXIMUM OF 15'-0" OC
6. REFER TO STRUCTUAL DRAWINGS FOR LOCATION OF REINFORCING, BEAMS, BRACING, ETC.
7. MAINTAIN POSITIVE FLOOR DRAINAGE TOWARD OPEN PERIMETER.
GRADE LEVEL
0"
BOTTOM OF BEAM
15' - 0"
E.4L D.4L C.4L B.4L A.4L
METAL ROOF
PREFINISHED ALUMINUM GUTTER
STAIN ALL POSTS AND EXTERIOR WOODWORK
CONTINUOUS TO INSIDE B.O. TRUSSWORK.
PRE-FINISHED ALUMINUM DOWNSPOUT
REFERENCE DETAIL
10x10 P.T POST. TYP.VEHICLE
FOOTPRINT
(WWSV /3 A3-01
KNEE BRACE, REFER TO STRUCTURAL
DRAWINGS
GRADE LEVEL
0"
BOTTOM OF BEAM
15' - 0"
3.4L 1.4L2.4L
18"x24" ALUMINUM
GABLE VENT WITH 50%
CLEAR AREA. INCLUDE
1/8" INSECT SCREEN
METAL ROOF
LAP FIBER CEMENT SIDING
COUNTERSINK BOLTS UNDER
FIBER CEMENT SIDING
IN BEAM ON GABLE ENDS
VEHICLE
FOOTPRINT
(WWSV)
2.L62.L7
KNEE BRACE, REFER TO
STRUCTURAL DRAWINGS
A3-01
TYP.
GRADE LEVEL
0"
BOTTOM OF BEAM
15' - 0"
3.4L1.4L 2.4L
18"x24" ALUMINUM
GABLE VENT WITH 50%
CLEAR AREA. INCLUDE
1/8" INSECT SCREEN
METAL ROOF
LAP FIBER CEMENT SIDING
COUNTERSINK BOLTS UNDER
FIBER CEMENT SIDING
IN BEAM ON GABLE ENDS
VEHICLE
FOOTPRINT
(WWSV)
2.L6 2.L7
KNEE BRACE, REFER TO
STRUCTURAL DRAWINGS
A3-01
TYP.
GRADE LEVEL
0"
BOTTOM OF BEAM
15' - 0"
E.4LD.4LC.4LB.4LA.4L
METAL ROOF
PREFINISHED ALUMINUM GUTTER
STAIN ALL POSTS AND EXTERIOR WOODWORK
CONTINUOUS TO INSIDE B.O. TRUSSWORK.
PRE-FINISHED ALUMINUM DOWNSPOUT
REFERENCE DETAIL
10x10 P.T POST. TYP.
VEHICLE
FOOTPRINT
(WWSV
/3 A3-01
KNEE BRACE, REFER TO STRUCTURAL
DRAWINGS
T 919 781 8582 F 919 781 3979
4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com
DRAWN BY:
CHECKED BY:
DESCRIPTIONDATEID
Th is d raw ing an d t he de sig n s ho wn rty of Sm ith Si nn ett
Ar ch ite he re pro du…