W9123624B2014_Ready To Advertise_Drawings_Jan_2024_Volume_2 of 2.pdf

PDF 23 MB Posted

Attached to
AIT Phase IV Headquarters Buildings
Solicitation number
W9123624B2014
Issued by

About this file

This document provides details on a forthcoming federal contract solicitation for construction services. The U.S. Army Corps of Engineers-Norfolk District will issue an Invitation for Bid for construction of two headquarters buildings at Fort Eustis in Newport News, Virginia. The work includes construction of a 10,900 square foot Battalion Headquarters Building and a 9,450 square foot Brigade Headquarters Building as single story facilities. Supporting construction involves site development, utilities, lighting, parking, storm drainage, landscaping, and information systems installation. Sustainability and energy efficiency measures are incorporated. The requirement will be set aside for small businesses with a NAICS code of 236220 and size standard of $45,000,000. The estimated price range for construction is between $10,000,000 to $25,000,000. The contract completion schedule is 540 calendar days. Prospective bidders must register in SAM and monitor for solicitation release on sam.gov. The Department of the Army Corps of Engineers Engineering District Norfolk is the issuing agency.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

G-001

C O

VE

R

S H

EE

T

K.

B

R O

D

BE

R

G . S

TO

C

K

R . B

LA

IR

K.

B

R O

D

BE

R

G -0

.D

W G

US Army Corps of Engineers ®

AIT BARRACKS COMPLEX PHASE 4 - HQ

PROJECT NUMBER: 73391

NORFOLK DISTRICT

SOLICITATION NO.: W9123624B2014

CONTRACT NO.: W9123624C2014

ARCHITECTURAL MECHANICAL ELECTRICALCIVIL STRUCTURAL FIRE PROTECTION

JOINT BASE LANGLEY-

EUSTIS (EUSTIS)

VICINITY MAPLOCATION MAP

N.T.S. N.T.S.

PROJECT LOCATION

MAIN GATE

JOINT BASE LANGLEY-EUSTIS (EUSTIS)

TELECOMMUNICATIONS

AN

SI

D

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

JA

N

U

AR

Y

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E U

ST

IS

AI

T

BA

R R

AC

KS

C O

M

PL

EX

P

H

AS

E

- H Q

PR

O

JE

C

T N

U M

BE

R

: 7

SHEET ID

HQ

FI

LE

N

AM

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

US Army Corps of Engineers

N

AO

F

IL

E N

O

FR

O

N T

ST

R

EE

T

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

N O

R

FO

LK

D

IS

TR

IC

T

N O

R

FO

LK

, V

IR

G

IN

IA

W

4B

W

4C

D

ES

C R

IP

TI

O N

R

AL

EI

G

H , N

C

-3

(9

1-

(9

) 8

-7

FA

X

LI

C

EN

SE

F -0

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

NAO FILE NO.: 972

801 JONES FRANKLIN ROAD, SUITE 300

RALEIGH, NC 27606-3394

(919) 851-6866

(919) 851-7024 FAX

LICENSE # F-0672

CHARLOTTE | 704.295.4263

705 EAST MOREHEAD STREET, 28202

RALEIGH | 919.816.2907

3737 GLENWOOD AVENUE, SUITE 100, 27612

NC License No: C-2848

AME Project No: 17047

SUMMER

CONSULTANTS

I N C O R P O R A T E D

ISSUE DATE: JANUARY 2024

VOLUME: II OF II

READY TO ADVERTISE (RTA)

01/26/2024 01/29/202401/31/202401.

29.

TITLESHEET ID. FILENAME TITLESHEET ID. FILENAME

G-002

IN

D

EX

O

F D

R

AW

IN

G

S

- V

O

LU

M E

II

O

F

II

W B

M M

R D

W B

G -0

.D

W G

TITLEFILENAMESHEET ID.

INDEX OF DRAWINGS - VOLUME I

AN

SI

D

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

JA

N

U

AR

Y

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E U

ST

IS

AI

T

BA

R R

AC

KS

C O

M

PL

EX

P

H

AS

E

- H Q

PR

O

JE

C

T N

U M

BE

R

: 7

SHEET ID

HQ

FI

LE

N

AM

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

US Army Corps of Engineers

N

AO

F

IL

E N

O

FR

O

N T

ST

R

EE

T

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

N O

R

FO

LK

D

IS

TR

IC

T

N O

R

FO

LK

, V

IR

G

IN

IA

W

4B

W

4C

D

ES

C R

IP

TI

O N

R

AL

EI

G

H , N

C

-3

(9

1-

(9

) 8

-7

FA

X

LI

C

EN

SE

F -0

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

GENERAL

G-001 G-001.DWG COVER SHEET

G-002 G-002.DWG INDEX OF DRAWINGS - VOLUME I OF II

G-003 G-003.DWG INDEX OF DRAWINGS - VOLUME II OF II

G-004 G-004.DWG INSTALLATION MAP AND PROJECT LOCATION MAP

CIVIL

VF101 VF101.DWG SITE TOPOGRAPHIC SURVEY

B-101 B-101.DWG SOIL TEST BORING LOCATIONS

BB601 BB601.DWG SOIL TEST BORING LOGS

BB602 BB602.DWG SOIL TEST BORING LOGS

C-001 C-001.DWG CIVIL LEGEND

CD101 CD101.DWG SITE DEMOLITION PLAN

CD101A CD101.DWG SITE DEMOLITION PLAN - BID OPTION 1

CS101 CS101.DWG SITE LAYOUT PLAN

CS101A CS101.DWG SITE LAYOUT PLAN - BID OPTION 1

CS102 CS102.DWG SITE PAVING, STRIPING AND SIGNAGE PLAN

CS102A CS102.DWG SITE PAVING, STRIPING AND SIGNAGE PLAN - BID OPTION 1

CS103 CS103.DWG FIRE LANE JOINT PLAN

CS201 CS201.DWG SITE ROAD PROFILES

CS501 CS501.DWG SITE LAYOUT DETAILS

CS502 CS502.DWG SITE LAYOUT DETAILS

CS503 CS503.DWG SITE LAYOUT DETAILS

CS701 CS701.DWG SITE LAYOUT TABLES

CG101 CG101.DWG SITE GRADING PLAN

CG101A CG101.DWG SITE GRADING PLAN - BID OPTION 1

CG102 CG102.DWG PHASE 1 SITE EROSION AND SEDIMENT CONTROL PLAN

CG103 CG103.DWG PHASE 2 SITE EROSION AND SEDIMENT CONTROL PLAN

CG103A CG103.DWG PHASE 2 SITE EROSION AND SEDIMENT CONTROL PLAN - BID OPTION 1

CG104 CG104.DWG STORM WATER MANAGEMENT PLAN

CG104A CG104.DWG STORM WATER MANAGEMENT PLAN - BID OPTION 1

CG105 CG105.DWG EXISTING DRAINAGE DIVIDES PLAN

CG106 CG106.DWG DESIGN DRAINAGE DIVIDES PLAN

CG106A CG106.DWG DESIGN DRAINAGE DIVIDES PLAN - BID OPTION 1

CG501 CG501.DWG SITE EROSION AND SEDIMENT CONTROL NOTES

CG502 CG502.DWG SITE EROSION AND SEDIMENT CONTROL NOTES

CG503 CG503.DWG SITE EROSION AND SEDIMENT CONTROL DETAILS

CG504 CG504.DWG SITE EROSION AND SEDIMENT CONTROL DETAILS

CG505 CG505.DWG STORM WATER MANAGEMENT DETAILS

CG506 CG506.DWG SITE EROSION AND SEDIMENT CONTROL NOTES

CG507 CG507.DWG SITE EROSION AND SEDIMENT CONTROL NOTES

CG508 CG508.DWG STORM WATER MANAGEMENT DETAILS

CU101 CU101.DWG SITE UTILITY PLAN

CU101A CU101.DWG SITE UTILITY PLAN - BID OPTION 1

CU201 CU201.DWG STORM DRAIN PROFILES

CU202 CU202.DWG SANITARY SEWER PROFILES

CU501 CU501.DWG STORM DRAIN DETAILS

CU502 CU502.DWG STORM DRAIN DETAILS

CU503 CU503.DWG STORM DRAIN DETAILS

CU504 CU504.DWG SANITARY SEWER DETAILS

CU505 CU505.DWG WATER LINE DETAILS AND NOTES

CU701 CU701.DWG SITE UTILITIES STRUCTURE AND PIPE TABLES

CU701A CU701.DWG SITE UTILITIES STRUCTURE AND PIPE TABLES

STRUCTURAL

BATTALION HEADQUARTERS (HQ-A)

S-001 S-001.DWG GENERAL NOTES

S-002 S-002.DWG GENERAL NOTES

S-003 S-003.DWG DESIGN DATA

S-004 S-004.DWG SPECIAL INSPECTIONS

S-005 S-005.DWG SPECIAL INSPECTIONS

S-006 S-006.DWG ISOMETRIC VIEW

S-007 S-007.DWG COLUMN SCHEDULE AND DETAILS

S-101 S-101.DWG FOUNDATION PLAN

S-102 S-102.DWG LOW ROOF PLAN

S-103 S-103.DWG UPPER AND MID ROOF PLAN

S-104 S-104.DWG MECHANICAL PLATFORM PLAN

S-105 S-105.DWG DUMPSTER ENCLOSURE PLAN AND DETAILS

S-201 S-201.DWG BUILDING ELEVATIONS

S-202 S-202.DWG BRACED FRAME ELEVATIONS

S-203 S-203.DWG BRACED FRAME ELEVATIONS

S-204 S-204.DWG BRACED FRAME DETAILS

S-301 S-301.DWG SECTIONS

S-302 S-302.DWG SECTIONS

S-303 S-303.DWG SECTIONS

S-501 S-501.DWG TYPICAL DETAILS

S-502 S-502.DWG TYPICAL DETAILS

S-503 S-503.DWG TYPICAL DETAILS

S-511 S-511.DWG TYPICAL DETAILS

S-521 S-521.DWG TYPICAL METAL STUD DETAILS

S-522 S-522.DWG TYPICAL METAL STUD DETAILS

AE501 AE501.DWG EXTERIOR PLAN DETAILS

AE502 AE502.DWG EXTERIOR SECTION DETAILS

AE503 AE503.DWG ROOF DETAILS

AE504 AE504.DWG ROOF DETAILS

AE505 AE505.DWG ROOF DETAILS

AE506 AE506.DWG ROOF HATCH AND SKYLIGHT DETAILS

AE507 AE507.DWG INTERIOR DETAILS

AE601 AE601.DWG DOOR SCHEDULE

AE602 AE602.DWG DOOR DETAILS

AE603 AE603.DWG LOUVER SCHEDULE AND DETAILS

AE604 AE604.DWG WINDOW TYPES, DETAILS AND SCHEDULE

AE701 AE701.DWG PARTITION TYPES

AE702 AE702.DWG PARTITION DETAILS

AE703 AE703.DWG THRU-WALL PENETRATIONS

AG101 AG101.DWG SIGNAGE PLAN

AG601 AG601.DWG SIGNAGE SCHEDULE AND MOUNTING

AG602 AG602.DWG SIGNAGE ELEVATIONS AND DETAILS

INTERIOR FURNISHINGS

BATTALION HEADQUARTERS (HQ-A)

I-101 I-101.DWG FINISH FLOOR PLAN

I-111 I-111.DWG FURNITURE PLAN

I-401 I-401.DWG RESTROOMS FINISH FLOOR PLAN

I-601 I-601.DWG FINISH KEY AND NOTES

I-602 I-602.DWG ROOM FINISH SCHEDULE

BRIGADE HEADQUARTERS (HQ-B)

I-101 I-101.DWG FINISH FLOOR PLAN - BID OPTION 1

I-111 I-111.DWG FURNITURE PLAN - BID OPTION 1

I-401 I-401.DWG RESTROOM FINISH FLOOR PLAN - BID OPTION 1

I-601 I-601.DWG FINISH KEY AND NOTES - BID OPTION 1

I-602 I-602.DWG ROOM FINISH SCHEDULE - BID OPTION 1

LANDSCAPE

LS101 LS101.DWG LANDSCAPE PLAN

LS102 LS102.DWG LANDSCAPE NOTES AND DETAILS

ARCHITECTURAL

BATTALION HEADQUARTERS (HQ-A)

AE001 AE001.DWG SYMBOLS AND ABBREVIATIONS

AE002 AE002.DWG ABA MOUNTING HEIGHTS AND CLEARANCES

AE003 AE003.DWG SITE DETAILS

AE010 AE010.DWG AIR BARRIER PLAN

AE011 AE011.DWG AIR BARRIER SECTIONS

AE101 AE101.DWG FLOOR PLAN

AE102 AE102.DWG DIMENSION PLAN

AE111 AE111.DWG MECHANICAL PLATFORM PLAN

AE121 AE121.DWG REFLECTED CEILING PLAN

AE131 AE131.DWG ROOF PLAN

AE201 AE201.DWG EXTERIOR ELEVATIONS

AE202 AE202.DWG EXTERIOR ELEVATIONS

AE301 AE301.DWG BUILDING SECTIONS

AE302 AE302.DWG WALL SECTIONS

AE303 AE303.DWG WALL SECTIONS

AE304 AE304.DWG WALL SECTIONS

AE401 AE401.DWG ENLARGED PLANS

AE402 AE402.DWG INTERIOR ELEVATIONS

AE403 AE403.DWG INTERIOR ELEVATIONS

AE404 AE404.DWG ENLARGED RESTROOM PLAN

AE405 AE405.DWG INTERIOR ELEVATIONS

AE406 AE406.DWG INTERIOR ELEVATIONS

AE407 AE407.DWG INTERIOR ELEVATIONS

AE410 AE410.DWG SHIPS LADDER PLAN, SECTION AND DETAILS

AE420 AE420.DWG MILLWORK SECTIONS AND DETAILS

AE421 AE421.DWG MILLWORK SECTIONS AND DETAILS

BRIGADE HEADQUARTERS (HQ-B)

AE001 AE001.DWG SYMBOL AND ABBREVIATIONS - BID OPTION 1

AE002 AE002.DWG ABA MOUNTING HEIGHTS AND CLEARANCES - BID OPTION 1

AE010 AE010.DWG AIR BARRIER PLAN - BID OPTION 1

AE011 AE011.DWG AIR BARRIER SECTIONS - BID OPTION 1

AE101 AE101.DWG FLOOR PLAN - BID OPTION 1

AE102 AE102.DWG DIMENSION PLAN - BID OPTION 1

AE111 AE111.DWG CLERESTORY PLAN - BID OPTION 1

AE121 AE121.DWG REFLECTED CEILING PLAN - BID OPTION 1

AE131 AE131.DWG ROOF PLAN - BID OPTION 1

AE201 AE201.DWG EXTERIOR ELEVATIONS - BID OPTION 1

AE202 AE202.DWG EXTERIOR ELEVATIONS - BID OPTION 1

AE301 AE301.DWG BUILDING SECTIONS - BID OPTION 1

AE302 AE302.DWG WALL SECTIONS - BID OPTION 1

AE303 AE303.DWG WALL SECTIONS - BID OPTION 1

AE304 AE304.DWG WALL SECTIONS - BID OPTION 1

AE401 AE401.DWG ENLARGED PLANS - BID OPTION 1

AE402 AE402.DWG INTERIOR ELEVATIONS - BID OPTION 1

AE403 AE403.DWG ENLARGED PLANS - BID OPTION 1

AE404 AE404.DWG INTERIOR ELEVATIONS - BID OPTION 1

AE405 AE405.DWG ENLARGED RESTROOM PLAN - BID OPTION 1

AE406 AE406.DWG INTERIOR ELEVATIONS - BID OPTION 1

AE407 AE407.DWG INTERIOR ELEVATIONS - BID OPTION 1

AE408 AE408.DWG INTERIOR CORRIDOR ELEVATIONS AT CLERESTORY - BID OPTION 1

AE409 AE409.DWG INTERIOR CORRIDOR ELEVATIONS AT CLERESTORY - BID OPTION 1

AE420 AE420.DWG MILLWORK SECTIONS AND DETAILS - BID OPTION 1

AE421 AE421.DWG MILLWORK SECTIONS AND DETAILS - BID OPTION 1

AE501 AE501.DWG PLAN DETAILS - BID OPTION 1

AE502 AE502.DWG PLAN DETAILS - BID OPTION 1

AE503 AE503.DWG SECTION DETAILS - BID OPTION 1

AE504 AE504.DWG METAL ROOF DETAILS - BID OPTION 1

AE505 AE505.DWG ROOF DETAILS - BID OPTION 1

AE506 AE506.DWG ROOF DETAILS - BID OPTION 1

AE507 AE507.DWG ROOF HATCH DETAILS - BID OPTION 1

AE508 AE508.DWG INTERIOR DETAILS - BID OPTION 1

AE601 AE601.DWG DOOR SCHEDULE - BID OPTION 1

AE602 AE602.DWG DOOR DETAILS - BID OPTION 1

AE603 AE603.DWG WINDOW TYPES AND SCHEDULE - BID OPTION 1

AE604 AE604.DWG WINDOW DETAILS - BID OPTION 1

AE605 AE605.DWG WINDOW DETAILS - BID OPTION 1

AE701 AE701.DWG PARTITION TYPES - BID OPTION 1

AE702 AE702.DWG PARTITION DETAILS - BID OPTION 1

AE703 AE703.DWG THRU-WALL PENETRATION DETAILS - BID OPTION 1

AG101 AG101.DWG SIGNAGE PLAN - BID OPTION 1

AG601 AG601.DWG SIGNAGE SCHEDULE AND MOUNTING - BID OPTION 1

AG602 AG602.DWG SIGNAGE TYPES - BID OPTION 1

BRIGADE HEADQUARTERS (HQ-B)

S-001 S-001.DWG GENERAL NOTES - BID OPTION 1

S-002 S-002.DWG GENERAL NOTES - BID OPTION 1

S-003 S-003.DWG DESIGN DATA - BID OPTION 1

S-004 S-004.DWG SPECIAL INSPECTIONS - BID OPTION 1

S-005 S-005.DWG SPECIAL INSPECTIONS - BID OPTION 1

S-006 S-006.DWG ISOMETRIC VIEW - BID OPTION 1

S-007 S-007.DWG COLUMN SCHEDULE AND DETAILS - BID OPTION 1

S-101 S-101.DWG FOUNDATION PLAN - BID OPTION 1

S-102 S-102.DWG LOW ROOF PLAN - BID OPTION 1

S-103 S-103.DWG HIGH ROOF PLAN - BID OPTION 1

S-201 S-201.DWG BUILDING ELEVATIONS - BID OPTION 1

S-202 S-202.DWG BUILDING ELEVATIONS - BID OPTION 1

S-203 S-203.DWG BUILDING ELEVATIONS - BID OPTION 1

S-204 S-204.DWG MOMENT FRAME ELEVATIONS - BID OPTION 1

S-205 S-205.DWG MOMENT FRAME ELEVATIONS AND DETAILS - BID OPTION 1

S-301 S-301.DWG SECTIONS - BID OPTION 1

S-302 S-302.DWG SECTIONS - BID OPTION 1

S-303 S-303.DWG SECTIONS - BID OPTION 1

S-501 S-501.DWG FOUNDATION DETAILS - BID OPTION 1

S-502 S-502.DWG FOUNDATION DETAILS - BID OPTION 1

S-503 S-503.DWG FOUNDATION DETAILS - BID OPTION 1

S-511 S-511.DWG TYPICAL DETAILS - BID OPTION 1

S-521 S-521.DWG TYPICAL METAL STUD DETAILS - BID OPTION 1

S-522 S-522.DWG TYPICAL METAL STUD DETAILS - BID OPTION 1

01/26/2024

TITLESHEET ID. FILENAME TITLESHEET ID. FILENAME

G-003

IN

D

EX

O

F D

R

AW

IN

G

S

- V

O

LU

M E

II

O

F

II

K.

B

R O

D

BE

R

G . S

TO

C

K

R . B

LA

IR

K.

B

R O

D

BE

R

G -0

.D

W G

TITLEFILENAMESHEET ID.

INDEX OF DRAWINGS - VOLUME II

AN

SI

D

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

JA

N

U

AR

Y

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E U

ST

IS

AI

T

BA

R R

AC

KS

C O

M

PL

EX

P

H

AS

E

- H Q

PR

O

JE

C

T N

U M

BE

R

: 7

SHEET ID

HQ

FI

LE

N

AM

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

US Army Corps of Engineers

N

AO

F

IL

E N

O

FR

O

N T

ST

R

EE

T

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

N O

R

FO

LK

D

IS

TR

IC

T

N O

R

FO

LK

, V

IR

G

IN

IA

W

4B

W

4C

D

ES

C R

IP

TI

O N

R

AL

EI

G

H , N

C

-3

(9

1-

(9

) 8

-7

FA

X

LI

C

EN

SE

F -0

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

LIFE SAFETY

BATTALION HEADQUARTERS (HQ-A)

GI001 GI001.DWG BUILDING CODE AND LIFE SAFETY SUMMARY

GI101 GI101.DWG LIFE SAFETY PLAN

BRIGADE HEADQUARTERS (HQ-B)

GI001 GI001.DWG BUILDING CODE AND LIFE SAFETY SUMMARY - BID OPTION 1

GI101 GI101.DWG LIFE SAFETY PLAN - BID OPTION 1

GENERAL

G-001 G-001.DWG COVER SHEET

G-002 G-002.DWG INDEX OF DRAWINGS - VOLUME I OF II

G-003 G-003.DWG INDEX OF DRAWINGS - VOLUME II OF II

ELECTRICAL

BATTALION HEADQUARTERS (HQ-A)

E-001 E-001.DWG ELECTRICAL SYMBOLS AND ABBREVIATIONS

ES101 ES101.DWG ELECTRICAL SITE PLAN

EL101 EL101.DWG FLOOR PLAN - LIGHTING

EL102 EL102.DWG MECHANICAL PLATFORM PLAN - LIGHTING

EP101 EP101.DWG FLOOR PLAN - POWER

EP102 EP102.DWG MECHANICAL PLATFORM PLAN - POWER

EP401 EP401.DWG ENLARGED FLOOR PLAN - POWER

E-501 E-501.DWG ELECTRICAL DETAILS

E-502 E-502.DWG ELECTRICAL DETAILS

E-601 E-601.DWG ELECTRICAL SCHEDULES

E-602 E-602.DWG ELECTRICAL SINGLE LINE DIAGRAM

E-603 E-603.DWG ELECTRICAL SCHEDULES

E-604 E-604.DWG ELECTRICAL SCHEDULES

E-605 E-605.DWG ELECTRICAL SCHEDULES

BRIGADE HEADQUARTERS (HQ-B)

E-001 E-001.DWG ELECTRICAL SYMBOLS AND ABBREVIATIONS - BID OPTION 1

ES101 ES101.DWG ELECTRICAL SITE PLAN - BID OPTION 1

EL101 EL101.DWG FLOOR PLAN - LIGHTING - BID OPTION 1

EP101 EP101.DWG FLOOR PLAN - POWER - BID OPTION 1

EP401 EP401.DWG ENLARGED FLOOR PLAN - POWER - BID OPTION 1

E-501 E-501.DWG ELECTRICAL DETAILS - BID OPTION 1

E-502 E-502.DWG ELECTRICAL DETAILS - BID OPTION 1

E-601 E-601.DWG ELECTRICAL SCHEDULES - BID OPTION 1

E-602 E-602.DWG ELECTRICAL SINGLE LINE DIAGRAM - BID OPTION 1

E-603 E-603.DWG ELECTRICAL SCHEDULES - BID OPTION 1

E-604 E-604.DWG ELECTRICAL SCHEDULES - BID OPTION 1

E-605 E-605.DWG ELECTRICAL SCHEDULES - BID OPTION 1

TELECOMMUNICATIONS

BATTALION HEADQUARTERS (HQ-A)

T-001 T-001.DWG TELECOM - GENERAL NOTES AND LEGEND

TS101 TS101.DWG TELECOM - PARTIAL SITE PLAN

TN101 TN101.DWG TELECOM - FLOOR PLAN - DATA

TY101 TY101.DWG SECURITY - FLOOR PLAN

T-401 T-401.DWG TELECOM - ENLARGED PLANS

T-501 T-501.DWG TELECOM - DETAILS

T-502 T-502.DWG TELECOM - DETAILS

T-503 T-503.DWG TELECOM - DETAILS

T-504 T-504.DWG TELECOM - DETAILS

T-505 T-505.DWG TELECOM - DETAILS

T-506 T-506.DWG TELECOM - DETAILS

T-507 T-507.DWG TELECOM - DETAILS

T-508 T-508.DWG TELECOM - DETAILS

T-601 T-601.DWG TELECOM - RISER DIAGRAM

BRIGADE HEADQUARTERS (HQ-B)

T-001 T-001.DWG TELECOM - GENERAL NOTES AND LEGEND - BID OPTION 1

TS101 TS101.DWG TELECOM - PARTIAL SITE PLAN - BID OPTION 1

TN101 TN101.DWG TELECOM - FLOOR PLAN - DATA - BID OPTION 1

TY101 TY101.DWG SECURITY - FLOOR PLAN - BID OPTION 1

T-401 T-401.DWG TELECOM - ENLARGED PLANS - BID OPTION 1

T-501 T-501.DWG TELECOM - DETAILS - BID OPTION 1

T-502 T-502.DWG TELECOM - DETAILS - BID OPTION 1

T-503 T-503.DWG TELECOM - DETAILS - BID OPTION 1

T-504 T-504.DWG TELECOM - DETAILS - BID OPTION 1

T-505 T-505.DWG TELECOM - DETAILS - BID OPTION 1

T-506 T-506.DWG TELECOM - DETAILS - BID OPTION 1

T-507 T-507.DWG TELECOM - DETAILS - BID OPTION 1

T-508 T-508.DWG TELECOM - DETAILS - BID OPTION 1

T-601 T-601.DWG TELECOM - RISER DIAGRAM - BID OPTION 1

FIRE PROTECTION

BATTALION HEADQUARTERS (HQ-A)

FA001 FA001.DWG FIRE ALARM SYMBOLS AND NOTES

FA101 FA101.DWG FIRE ALARM PLAN

FX001 FX001.DWG FIRE PROTECTION NOTES AND ABBREVIATIONS

FX101 FX101.DWG FIRE PROTECTION PLAN

BRIGADE HEADQUARTERS (HQ-B)

FA001 FA001.DWG FIRE ALARM SYMBOLS AND NOTES - BID OPTION 1

FA101 FA101.DWG FIRE ALARM PLAN - BID OPTION 1

FX001 FX001.DWG FIRE PROTECTION NOTES AND ABBREVIATIONS - BID OPTION 1

FX101 FX101.DWG FIRE PROTECTION PLAN - BID OPTION 1

MECHANICAL

BATTALION HEADQUARTERS (HQ-A)

M-001 M-001.DWG MECHANICAL SYMBOLS AND ABBREVIATIONS

MS101 MS101.DWG MECHANICAL SITE PLAN

MH101 MH101.DWG FLOOR PLAN - DUCTWORK

MH102 MH102.DWG MECHANICAL PLATFORM PLAN - DUCTWORK

MP101 MP101.DWG FLOOR PLAN - PIPING

MP102 MP102.DWG MECHANICAL PLATFORM PLAN - PIPING

M-301 M-301.DWG MECHANICAL CONTROL DIAGRAMS

M-302 M-302.DWG MECHANICAL CONTROL DIAGRAMS

M-303 M-303.DWG MECHANICAL CONTROL DIAGRAMS

M-304 M-304.DWG MECHANICAL CONTROL DIAGRAMS

M-305 M-305.DWG MECHANICAL CONTROL DIAGRAMS

M-306 M-306.DWG MECHANICAL CONTROL DIAGRAMS

M-401 M-401.DWG ENLARGED MECHANICAL ROOM PLANS

M-501 M-501.DWG MECHANICAL DETAILS

M-502 M-502.DWG MECHANICAL DETAILS

M-503 M-503.DWG MECHANICAL DETAILS

M-601 M-601.DWG MECHANICAL SCHEDULES

M-602 M-602.DWG MECHANICAL SCHEDULES

BRIGADE HEADQUARTERS (HQ-B)

M-001 M-001.DWG MECHANICAL SYMBOLS AND ABBREVIATIONS - BID OPTION 1

MS101 MS101.DWG MECHANICAL SITE PLAN - BID OPTION 1

MH101 MH101.DWG FLOOR PLAN - DUCTWORK - BID OPTION 1

MP101 MP101.DWG FLOOR PLAN - PIPING - BID OPTION 1

M-301 M-301.DWG MECHANICAL CONTROL DIAGRAMS - BID OPTION 1

M-302 M-302.DWG MECHANICAL CONTROL DIAGRAMS - BID OPTION 1

M-303 M-303.DWG MECHANICAL CONTROL DIAGRAMS - BID OPTION 1

M-304 M-304.DWG MECHANICAL CONTROL DIAGRAMS - BID OPTION 1

M-401 M-401.DWG ENLARGED MECHANICAL ROOM PLANS - BID OPTION 1

M-501 M-501.DWG MECHANICAL DETAILS - BID OPTION 1

M-502 M-502.DWG MECHANICAL DETAILS - BID OPTION 1

M-503 M-503.DWG MECHANICAL DETAILS - BID OPTION 1

M-601 M-601.DWG MECHANICAL SCHEDULES - BID OPTION 1

M-602 M-602.DWG MECHANICAL SCHEDULES - BID OPTION 1

PLUMBING

BATTALION HEADQUARTERS (HQ-A)

P-001 P-001.DWG PLUMBING SYMBOL & ABBREVIATIONS

PL101 PL101.DWG FIRST FLOOR - PLUMBING WASTE AND VENT PLAN

PL102 PL102.DWG FIRST FLOOR - PLUMBING WATER DISTRIBUTION PLAN

PL103 PL103.DWG ROOF - PLUMBING PLAN

PL401 PL401.DWG ENLARGED PLAN - PLUMBING WATER DISTRIBUTION PLAN

PL402 PL402.DWG ENLARGED PLAN -PLUMBING WASTE AND VENT PLAN

P-501 P-501.DWG PLUMBING DETAILS

P-502 P-502.DWG PLUMBING DETAILS

P-601 P-601.DWG PLUMBING SCHEDULES

P-901 P-901.DWG PLUMBING RISER DIAGRAMS

P-902 P-902.DWG PLUMBING RISER DIAGRAMS

BRIGADE HEADQUARTERS (HQ-B)

P-001 P-001.DWG PLUMBING SYMBOLS & ABBREVIATIONS - BID OPTION 1

PL101 PL101.DWG FIRST FLOOR - PLUMBING WASTE AND VENT PLAN - BID OPTION 1

PL102 PL102.DWG FIRST FLOOR - PLUMBING WATER DISTRIBUTION WATER PLAN - BID OPTION 1

PL103 PL103.DWG ROOF - PLUMBING PLAN - BID OPTION 1

PL401 PL401.DWG ENLARGED PLAN - PLUMBING WATER DISTRIBUTION PLAN - BID OPTION 1

PL402 PL402.DWG ENLARGED PLAN - PLUMBING WASTE AND VENT PLAN - BID OPTION 1

P-501 P-501.DWG PLUMBING DETAILS - BID OPTION 1

P-502 P-502.DWG PLUMBING DETAILS - BID OPTION 1

P-601 P-601.DWG PLUMBING SCHEDULES - BID OPTION 1

P-901 P-901.DWG PLUMBING RISER DIAGRAMS - BID OPTION 1

01/26/2024

JA

N

01/31/2024

SYMBOLS DEFINITION

ABBREVIATION DEFINITION ABBREVIATION DEFINITION

SYMBOLS DEFINITION

LEGEND AND ABBREVIATIONS

ASPE

ATM

BTUH

CONT

CO

DCW

DEG

FCO

GAL

GC

GPM

H

HD

DHW

DHWR

IN

IN

IN

IPS

L

DIA

EL

AFF

FT

FU

ANSI

ASME

GPH

AMP

AGA

AG

HGT

HP

FF

FL

EC

BTU

FT

FT

N C

N O

N/A

NFPA

NIC

NTS

NO

OZ

PC

PRV

PSI

R

RDL

RPZ

LB

LBS

OD

AMERICAN SOCIETY OF PLUMBING ENGINEERS

ATMOSPHERE

BRITISH THERMAL UNITS PER HOUR

CONTINUED

CLEANOUT

DOMESTIC COLD WATER

DEGREE

FLOOR CLEANOUT

GALLON

GENERAL CONTRACTOR

GALLON PER MINUTE

HYDROGEN

HEAD

DOMESTIC HOT WATER

DOMESTIC HOT WATER RETURN

INCH/INCHES

SQUARE INCH(ES)

CUBIC INCH(ES)

IRON PIPE SIZE

LENGTH

DIAMETER

ELEVATION

ABOVE FINISHED FLOOR

FOOT/FEET

FIXTURE UNIT

AMERICAN NATIONAL STANDARDS INSTITUTE

AMERICAN SOCIETY OF MECHANICAL ENGINEERS

GALLON PER HOUR

AMPERE

AMERICAN GAS ASSOCIATION

ABOVE GROUND

HEIGHT

HORSEPOWER

FINISHED FLOOR

FLOOR

ELECTRICAL CONTRACTOR

BRITISH THERMAL UNITS

SQUARE FOOT/FEET

CUBIC FOOT/FEET

NORMALLY CLOSED

NORMALLY OPEN

NOT APPLICABLE

NATIONAL FIRE PROTECTION ASSOCIATION

NOT IN CONTRACT

NOT TO SCALE

NUMBER

OUNCE(S)

PLUMBING CONTRACTOR

PRESSURE REDUCING VALVE

POUNDS PER SQUARE INCH

THERMAL RESISTANCE

ROOF DRAIN LEADER

REDUCED PRESSURE ZONE

POUND

POUNDS

OVERFLOW DRAIN

FFE FINISHED FLOOR ELEVATION

HR HOUR

MIN MINUTE

NPS NOMINAL PIPE SIZE

DC DOUBLE CHECK

A ARGON

CA COMPRESSED AIR

CL CHLORINE

CIP CAST IRON PIPE

CISPI CAST IRON SOIL AND PIPE INSTITUTE

DIP DUCTILE IRON PIPE

CU COPPER

DI DE-IONIZED WATER

MA MEDICAL AIR

F FLUORINE

HE HELIUM

HG MERCURY

LPG LIQUIFIED PETROLEUM GAS

N NITROGEN

NG NATURAL GAS

N2O NITROUS OXIDE

OX OXYGEN

POC POINT OF CONNECTION

AHJ AUTHORITY HAVING JURISDICTION

EQUIPMENT DESIGNATION

EXTERIOR CLEANOUT

HOSE BIBB

INTERIOR FLOOR CLEANOUT

MIXING VALVE

UNION

WALL CLEANOUT

TEMPERATURE & PRESSURE RELIEF VALVE

DOUBLE CHECK BACKFLOW PREVENTER

CHECK VALVE

BALL VALVE

ROOF DRAIN

PUMP

TRAP PRIMER VALVE

FLOOR SINK

FLOOR DRAIN

POINT OF CONNECTION TO EXISTING

REDUCED PRESSURE ZONE BACKFLOW PREVENTER

WATER HAMMER ARRESTOR

CIRCUIT SETTER

SYMBOLS DEFINITION

DETAIL CALLOUT

REVISION CALLOUT

KEYNOTE T AG

IE INVERT ELEVATION

FD FLOOR DRAIN

AD AREA DRAIN

FS FLOOR SINK

REFER

SANITARY

DOMESTIC COLD WATER

DOMESTIC HOT WATER RETURN

DOMESTIC HOT WATERDHW

DHWR

SAN

DCW

LINETYPES DEFINITIONS

SANITARY VENTV

SOLAR WATER SUPPLY

SOLAR WATER RETURNSWR

SWS

LINETYPES DEFINITIONS

SPEC

SQ

SS

SAN

STD

T

TEMP

UG

UL

VERT

VTR

WCO

WHA

W

SPECIFICATION(S)

SQUARE

STAINLESS STEEL

SANITARY SEWER

STANDARD

TEMPERATURE

TEMPERATURE DIFFERENCE

UNDERGROUND

UNDERWRITERS LABORATORIES

VERTICAL

VENT THROUGH ROOF

WALL CLEANOUT

WATER HAMMER ARRESTOR

WIDTH

SEC SECOND

VAC VACUUM

WT WEIGHT

V SANITARY VENT

VIV VALVE IN VERTICAL

TW TEMPERED WATER

SIM SIMILAR

TD TRENCH DRAIN

X EXISTING

TPV TRAP PRIMER VALVE

SPG SPECIALTY GAS

TYP TYPICAL

WC WATER CLOSET

UR URINAL

SWS SOLAR WATER SUPPLY

SWR SOLAR WATER RETURN

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

P-001

PL

U

M

BI

N G

S

YM

BO

L

AB

BR

EV

IA

TI

O N

S

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-A

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

P -0 .D W G

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

PL402

3.63.3 43 5 6 7

E.8

E.6

D.8

D

C.2

C

B

C.9

A

F

D.2

E

PL402

VESTIBULE

MECHANICAL

122A

STORAGE

BN CSM

BN XO

BN CO

BREAK ROOM

110A

VESTIBULE

CHAPLAIN

ASSISTANT

CHAPLAIN

S-4

S-3

VESTIBULE

A/V

SUPPLY

STORAGE

OPEN OFFICES

S-1

RECYCLING

124B

VENDING

124C

LOBBY

STAFF DUTY

CONFERENCE

116 MEN

WOMEN

LACTATION

MEN LOCKER

ROOM

WOMEN LOCKER

ROOM

RECYCLING

110B

COMM

MULTI-PURPOSE

CORRIDOR

124A

ELEC

122C

CUSTODIAL

122D

1-HOUR RATED FIRE PARTITION

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

PL101

FI

R

ST

F

LO

O

R

PL

U

M

BI

N G

W

AS

TE

A

N D

V

EN

T

PL

AN

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-A

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

0 4 8 16'

1/8" = 1'-0"

SCALE: 1/8" = 1'-0"B2 FIRST FLOOR - PLUMBING WASTE AND VENT PLAN

P L .D W G

N

TRUE NORTH

GENERAL NOTE:

1. SEAL ALL PENETRATIONS THROUGH PARTITIONS WITH STC

REQUIREMENTS. REFER TO ARCHITECTURAL DRAWINGS FOR

ADDITIONAL INFORMATION / REQUIREMENTS

M

AR

K D

ES

C

R

IP

TI

O

N D

PL401

3.63.3 43 5 6 7

E.8

E.6

D.8

D

C.2

C

B

C.9

A

F

D.2

E

PL401

VESTIBULE

MECHANICAL

122A

STORAGE

BN CSM

BN XO

BN CO

BREAK ROOM

110A

VESTIBULE

CHAPLAIN

ASSISTANT

CHAPLAIN

S-4

S-3

VESTIBULE

A/V

SUPPLY

STORAGE

OPEN OFFICES

S-1

RECYCLING

124B

VENDING

124CLOBBY

STAFF DUTY

CONFERENCE

MEN

WOMEN

LACTATION

MEN LOCKER

ROOM

WOMEN LOCKER

ROOM

RECYCLING

110B

COMM

MULTI-PURPOSE

CORRIDOR

124A

ELEC

122CCUSTODIAL

122D

1-HOUR RATED FIRE PARTITION

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

PL102

FI

R

ST

F

LO

O

R

PL

U

M

BI

N G

W

AT

ER

D

IS

TR

IB

U

TI

O

N

PL

AN

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-A

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

SCALE: 1/8" = 1'-0"A2 FIRST FLOOR - PLUMBING WATER DISTRIBUTION PLAN

0 4 8 16'

1/8" = 1'-0"

P L .D W G

N

TRUE NORTH

GENERAL NOTE:

1. SEAL ALL PENETRATIONS THROUGH PARTITIONS WITH STC

REQUIREMENTS. REFER TO ARCHITECTURAL DRAWINGS FOR

ADDITIONAL INFORMATION / REQUIREMENTS

M

AR

K D

ES

C

R

IP

TI

O

N D

3"VTR

3.63.3 43 5 6 7

E.8

E.6

D.8

D

C.2

C

B

C.9

A

F

D.2

E

2"VTR

SP-1

SOLAR SUPPLY

AND RETURN FROM

MECHANICAL

ROOM

SP-1

1 1/2" SWR

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

PL103

R O

O F

-P

LU

M

BI

N G

P

LA

N

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-A

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

SCALE: 1/8" = 1'-0"A2 ROOF - PLUMBING PLAN

0 4 8 16'

1/8" = 1'-0"

P L .D W G

N

TRUE NORTH

M

AR

K D

ES

C

R

IP

TI

O

N D

C1

/2

D

C W

/4

D

H W

R

/4

D

H W

1/2" DCW

1/2" DHWSK-1

ICE-1

D

C.9

A3

P-901

WHA-1

(TYP.2)

4 5 6 7

E.8

E.6

D.8

D

C.9

D.2

E

L-1

L-1 L-1

L-1

WC-1

WC-1

WC-2WC-2

UR-1

UR-1

SH-1SH-1

L-1 L-1

WC-2 WC-2

L-1

EWC-1

EWH-1

ET-1

BFP-1

BFP-2

TO MECHANICAL EQUIPMENT

SEE MECHANICAL DRAWINGS

REFER

CIVIL

MS-1

ST-1

PUMP-1

B7

PL401

1 1/2" DHW

3/4" DHWR

2 1/2" DCW

/2

S W

R

/2

S W

S

" D

C W

/4

" D H

W

2" DCW

1 1/2" DHW

3/4" DHWR

/2

" D C

W

/4

" D H

W

/4

" D H

W R

2 1/2" DCW

1 1/2" DHW

3/4" DHWR

5' - 0"

2 1/2" DCW

ET-1

MV-1

HE-1

SOLAR HOT WATER PIPING

UP TO SOLAR PANEL

LOCATED ON ROOF

D1 P-902

D7 P-902

D1 P-902

D1 P-902

D1 P-902

WHA-2WHA-2

MECHANICAL

122A

VESTIBULE

A/V

RECYCLING

124B

VENDING

124C

MEN

120 WOMEN

LACTATION

MEN LOCKER

ROOM

WOMEN LOCKER

ROOM

COMM

CORRIDOR

124A

ELEC

122CCUSTODIAL

122D

FD-1

FD-1

FD-1

FD-1

FD-1

FD-2

TPV-1

WHA-1

(TYP.8)

WHA-1

WHA-1

(TYP.10)

WHA-2

(TYP.2)

HOT WATER RETURN BALANCING

VALVE ASSEMBLY (TYP.)

D C

W

/4

D

H W

/2

D C

W

/4 " D

H W

/2 " D

C W

/4

D

H W

R

1-HOUR RATED FIRE PARTITION

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

PL401

EN

LA

R G

ED

P

LA

N

PL

U M

BI

N

G W

AT

ER

D

IS

TR

IB

U

TI

O N

P

LA

N

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-A

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

0 2 4 8'

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"B7 ENLARGED PLAN - PLUMBING WATER DISTRIBUTION - BREAK ROOM

SCALE: 1/4" = 1'-0"C1 ENLARGED PLAN - PLUMBING WATER DISTRIBUTION - MECHANICAL ROOM/BATHROOM GROUP

P L .D W G

N

TRUE NORTH

GENERAL NOTE:

1. SEAL ALL PENETRATIONS THROUGH PARTITIONS WITH STC

REQUIREMENTS. REFER TO ARCHITECTURAL DRAWINGS FOR

ADDITIONAL INFORMATION / REQUIREMENTS

M

AR

K D

ES

C

R

IP

TI

O

N D

D

C.9

D.2

2" SAN

SK-1

B1

PL402

BREAK ROOM

110A

RECYCLING

110B

A3

P-902

FD-2

2" VTR

4 5 6 7

E.8

E.6

D.8

D

C.9

F

D.2

E

L-1

L-1 L-1

L-1

WC-1

WC-1

WC-2WC-2

UR-1

UR-1

SH-1SH-1

L-1

WC-2

WC-2

FD-1FD-1

REFER

CIVIL

IE: 29.39'

FD-1

L-1

FD-1

L-1

2" V

4" SAN

2" V

" V

2" V

3" SAN

4" SAN

" S

A N

4" SAN

4" SAN

4" SAN

3" SAN

" S

A N

S A

N

4" SAN

2" SAN

" V

" V

FD-1

FD-2

FD-2

FD-2

2"V UP FROM

BELOW

CO-2

IE: 31.66'

CO-2

IE: 31.79'

FD-2

FD-2

" V

4" SAN 4" SAN

4" SAN

MS-1

EWC-1

3" SAN3" SAN

2" SAN

2" SAN

3"V UP TO

VTR

C7

PL402

3" SAN

5'

0"

CO-2

IE: 29.83'

CO-1

IE: 30.35'

FFE: 33.10'

MECHANICAL

122A

STORAGE

VESTIBULE

A/V

RECYCLING

124B

VENDING

124C

MEN

WOMEN

LACTATION

MEN LOCKER

ROOM

WOMEN LOCKER

ROOM

COMM

CORRIDOR

124A

ELEC

122CCUSTODIAL

122D

D5

P-902

D5

P-902

D5

P-902

D5

P-902

D5

P-902

FD-2

1-HOUR RATED FIRE PARTITION

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

PL402

EN

LA

R G

ED

P

LA

N

PL

U M

BI

N

G W

AS

TE

A N

D V

EN

T

PL

AN

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-A

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

SCALE: 1/4" = 1'-0"C7 ENLARGED PLAN - PLUMBING WASTE AND VENT - BREAK ROOM

0 2 4 8'

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"B1

ENLARGED PLAN - PLUMBING WASTE AND VENT - MECHANICAL ROOM/BATHROOM

GROUP/CORRIDOR

P L .D W G

N

TRUE NORTH

GENERAL NOTE:

1. SEAL ALL PENETRATIONS THROUGH PARTITIONS WITH STC

REQUIREMENTS. REFER TO ARCHITECTURAL DRAWINGS FOR

ADDITIONAL INFORMATION / REQUIREMENTS

NOTES KEYED TO PLAN

IT IS THE DESIGN INTENT THAT VENT PIPING SERVING PLUMBING

FIXTURES IN RESTROOM(S) - MEN 120 & WOMEN 121, BE ROUTED

WITHIN THE PLUMBING CHASE. THE LOCATION NOTED ON PLANS

IS TO ALLOW FOR CLARITY OF DESIGN.

M

AR

K D

ES

C

R

IP

TI

O

N D

POLYISOCYANURATE INSERT (2" AND LARGER PIPE

SIZE). INSULATION JACKET TO BE INSTALLED OVER

INSERT. IF FLEXIBLE ELASTOMERIC WITHOUT

INSULATION JACKET IS USED, JOINTS AND SEAMS

BETWEEN INSULATION AND INSERT ARE

TO BE SEALED.

ADJUSTABLE

CLEVIS HANGER

THREADED

HANGER ROD

INSULATION SHIELD

PIPE INSULATION

PIPE INSULATION

PIPE

INSULATION SHIELDPOLYISOCYANURATE INSERT

THREADED

HANGER ROD

ADJUSTABLE

CLEVIS HANGER

PIPE

LOCATION OF

DISTRIBUTION UNIT FOR

MULTIPLE P-TRAPS (IF

REQUIRED)

COLD WATER

SUPPLY LINE

1/2" TYPE "K"

COPPER TRAP

PRIMER CONNECTION

DEEP SEAL P-TRAP

TRAP PRIMER VALVE

FINISHED FLOOR

WATERPROOF MEMBRANE (REFER

TO ARCHITECTURAL DRAWINGS FOR

APPLICABILITY

CONNECTION TO WATER SUPPLY

SHALL TAKE OFF FROM TOP OF

PIPE

1/2" ARMAFLEX

INSULATION

NO-HUB COUPLINGS

(HUB AND SPIGOT TYPE

IF BELOW GRADE)FLOOR DRAIN

THREADED WATER HAMMER ARRESTOR

(SIZED PER MAXIMUM PROBABLE FIXTURE

UNIT COUNT)

THREADED COUPLING (REDUCING COUPLING IF

WATER HAMMER ARRESTOR SIZE IS SMALLER

THAN CONNECTED WATER LINE SIZE)

THREADED TWO-PIECE FULL PORT QUARTER-TURN

BALL VALVE (SAME SIZE AS CONNECTED

WATER LINE SIZE)

UNION

(SOLDERED X THREADED)

THREADED NIPPLE

THREADED NIPPLE

CONNECTED WATER LINE

INSULATION (MINIMUM 1" THICK,

SEAL END OF INSULATION PER

MANUFACTUER'S INSTRUCTIONS)

NOTE: INSTALL ACCEPTABLE MEANS OF

PIPE SUPPORT S MAXIMUM OF 1'-6"

FROM CENTERLINE OF BALL VALVE)

DEEP SEAL P-TRAP

WATERPROOF MEMBRANE (REFER

TO ARCHITECTURAL DRAWINGS FOR

APPLICABILITY)

FINISHED FLOOR

NO-HUB COUPLINGS

(HUB AND SPIGOT TYPE

IF BELOW GRADE)

FLOOR SINK

BACKFLOW PREVENTER

PER SPECIFICATIONS

(OR APPROVED EQUAL)

ROUTE FROM

PUBLIC WATER

SYSTEM

PRESSURE

GAUGE

BALL VALVE

(N O)

Y-PATTERN

STRAINER

BALL VALVE (N C)

THREADED NIPPLE

WITH CAP

GATE VALVE

(N O)

GATE VALVE

(N O)

1' -0

(M

IN

IM

U M

5' -0

(M

A X

IM

U

M

* PIPE JOINTS SHALL BE CONSISTENT

WITH PIPING MATERIALS.

*INSTALL DIELECTRIC FITTING BETWEEN

DISSIMILAR MATERIALS.

B A

C K

F L O

W P

R E

V E

N T

E R

ROUTE TO

BUILDING

(ABOVE CEILING)

C L

FINISHED FLOOR

PRESSURE REDUCING VALVE

WILKINS MODEL 500

(OR APPROVED EQUAL)

SEQUENCE OF OPERATIONS

A. GENERAL

THIS IS A DOMESTIC HOT WATER SYSTEM AND INCLUDES A SOLAR HOT WATER SYSTEM ( SUPPLEMENTAL SUB-SYSTEM ), AN ELECTRIC WATER HEATER ( EWH-1 ), A THERMOSTATIC MASTER MIXING VALVE ( MV-1 ), EXPANSION TANK ( ET-1 ) AND A RECIRCULATION PUMP ( PUMP-1 ).

DOMESTIC HOT WATER IS PROVIDED TO THE BUILDING VIA A CONNECTION TO THE MASTER MIXING VALVE.

THE MASTER MIXING VALVE IS PROVIDING DOMESTIC HOT WATER VIA A CONNECTION TO THE ELECTRIC HOT WATER HEATER AND DOMESTIC COLD WATER SYSTEM..

A DOMESTIC HOT WATER RECIRCULATION PUMP IS PROVIDED FOR THE BUILDING DOMESTIC HOT WATER SYSTEM AND CIRCULATES THE DOMESTIC HOT WATER THROUGH THE RECIRCULATION LOOP AND TIES BACK INTO CONNECTION BETWEEN THE SOLAR HOT WATER STORAGE

TANK AND THE ELECTRIC HOT WATER HEATER.

ALL COMPONENTS SHALL BE MANUALLY INDEXED TO THE AUTOMATIC OPERATION POSITION. THE NEW BUILDING AUTOMATION SYSTEM (BAS) SHALL MONITOR THE DOMESTIC HOT WATER SYSTEM.

B. SOLAR HOT WATER SYSTEM ( SUB-SYSTEM )

THE SOLAR HOT WATER SYSTEM SHALL PROVIDE HOT WATER TO THE BUILDING DOMESTIC HOT WATER SYSTEM AND INCLUDES A SOLAR ARRAY ( SP-1), A STORAGE TANK ( ST-1 ), A HEAT EXCHANGER (HE-1), AND EXPANSION TANK ( ET-1).

THE SOLAR WATER HEATER CONTROL SYSTEM SHALL MONITOR THE TEMPERATURE OF WATER WITHIN THE SOLAR HOT WATER STORAGE TANK, VIA A TEMPERATURE SENSOR LOCATED INSIDE THE SOLAR WATER HEATER STORAGE TANK.

THE SOLAR WATER HEATER CONTROL SYSTEM SHALL MONITOR THE TEMPERATURE OF THE HEAT TRANSFER FLUID WITHIN THE SOLAR ARRAY, VIA A TEMPERATURE SENSOR LOCATED AT THE SOLAR ARRAY.

UPON SENSING A TEMPERATURE DIFFERENTIAL INDICATING THE HEAT TRANSFER FLUID IN THE SOLAR ARRAY IS A HIGHER TEMPERATURE THAN THAT OF THE DOMESTIC WATER IN THE SOLAR WATER HEATER STORAGE TANK, THE SOLAR WATER HEATER CONTROL SYSTEM SHALL ENERGIZE THE HEAT TRANSFER SYSTEM CIRCULATION PUMP AND CIRCULATE HEAT TRANSFER FLUID BETWEEN THE SOLAR ARRAY AND THE HEAT EXCHANGER AND DOMESTIC WATER FROM THE SOLAR WATER HEATER STORAGE TANK.

C. DOMESTIC HOT WATER HEATER CONTROL

THE DOMESTIC HOT WATER HEATER CONTROL SYSTEM SHALL MONITOR THE TEMPERATURE OF WATER SUPPLIED BY THE SOLAR HOT WATER STORAGE TANK, VIA A TEMPERATURE SENSOR LOCATED INSIDE THE ELECTRIC HOT WATER TANK.

UPON SENSING A TEMPERATURE INSIDE THE ELECTRIC HOT WATER TANK THAT IS BELOW THE DESIRED DOMESTIC HOT WATER TEMPERATURE SET POINT, THE CONTROL SYSTEM OF THE ELECTRIC HOT WATER HEATER WILL ENERGIZE TO RAISE THE DOMESTIC HOT WATER TEMPERATURE

TO THE DESIRED DOMESTIC HOT WATER TEMPERATURE SET POINT.

UPON ACHIEVING THE DOMESTIC HOT WATER TEMPERATURE SET POINT THE ELECTRIC HOT WATER HEATER WILL DE-ENERGIZE.

D. THERMOSTATIC MASTER MIXING VALVE

A THERMOSTATIC MIXING VALVE SHALL SENSE INCOMING DOMESTIC HOT WATER TEMPERATURE AND MODULATE INCOMING DOMESTIC COLD WATER IN SUFFICIENT QUANTITY TO BLEND THE FINAL DELIVERED DOMESTIC HOT WATER TEMPERATURE TO THE DESIRED DOMESTIC HOT WATER

TEMPERATURE SET POINT.

E. DOMESTIC HOT WATER RECIRCULATION PUMP

AN AQUASTAT SHALL MONITOR THE DOMESTIC HOT WATER RETURN TEMPERATURE. UPON SENSING A DOMESTIC HOT WATER RETURN TEMPERATURE THAT IS BELOW THE DESIRED DOMESTIC HOT WATER TEMPERATURE SET POINT, THE DOMESTIC HOT WATER RECIRCULATION PUMP

CONTROLLER WILL ENERGIZE THE DOMESTIC HOT WATER RECIRCULATION PUMP.

UPON SENSING A DOMESTIC HOT WATER RETURN TEMPERATURE THAT IS AT THE DESIRED DOMESTIC HOT WATER RETURN TEMPERATURE SET POINT THE DOMESTIC HOT WATER RECIRCULATION PUMP WILL DE-ENERGIZE.

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

P-501

PL

U

M

BI

N G

D

ET

AI

LS

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-A

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

SCALE: NOT TO SCALEP-501

F2 CLEVIS PIPE HANGER

SCALE: NOT TO SCALEP-501

C2 FLOOR DRAIN W/TRAP PRIMER

SCALE: NOT TO SCALEP-501

F8 WATER HAMMER ARRESTOR

SCALE: NOT TO SCALEP-501

F5 FLOOR DRAIN W/O TRAP PRIMER

SCALE: NOT TO SCALEP-501

A1 DOUBLE CHECK BACKFLOW PREVENTER

P -5 .D W G

SCALE: 12" = 1'-0"P-501

M

AR

K D

ES

C

R

IP

TI

O

N D

DRAIN

V

ALVE

AIR VENT

CAPPED OFF

CAPPED OFF

UNION

UNION

SP

-1

SP

-1

HEAT T

RANSFER F

LUID

S

UPPLY P

IP

IN

G

HEAT T

RANSFER

FLUID

R

ETURN

PIP

IN

G

VA

CU

UM

BR

EA

KE

R

HW

S O

UTLET

DC

W

CHECK V

ALVE

T&P V

ALVE

ROUTE T

O F

LOOR D

RAIN

OR E

XTERIO

R S

PLASH B

LOCK

SENSOR

LOCATION

DRAIN

V

ALVE

HE-1

ET

-1

ST

-1

VA

CU

UM

BR

EA

KE

R

DH

W

DCW

/D

HW

IN

LET

GATE VALVE (N

O)

GATE VALVE (N

O)

DH

W

DC

W

T&P V

ALVE

DRAIN

O

R E

XTERIO

R

SPLASH B

LOCK

DRAIN

V

ALVE

MV

-1

EW

H-

IN

LE

T

OU

TL

ET

M

IN

IM

U M

ROUTE T

O FLOOR

M

IN

IM

U M

SENSOR

LOCATION

SEALED R

OOF P

ENETRATIO

N

SEALED R

OOF P

ENETRATIO

NS

ET

-1

GA

TE

VA

LV

E

(NO

GATE VALVE (N

O)

DH

W R

GA

TE

VA

LV

E

(NC

CHECK V

ALVE

PU

MP

-1

CHECK V

ALVE

BALL V

ALVE

BALL V

ALVE

ADJUSTABLE BASE LEG

ADJUSTABLE BASE LEG

SOLAR COLLECTOR

MOUNTING ANGLE

ADJUSTABLE BASE LEG

ADJUSTABLE BASE LEG

SHOE AND SPACER

MOUNTING ANGLE

MOUNTING CLIP

DETAIL "C"DETAIL "B"DETAIL "A" DETAIL "D"

M

IN

IM

U M

MOUNTING CLIP

36°

ROOF SURFACE

SHOE AND

SPACER

MOUNTING CLIP

AND SHOE

REFER TO MANUFACTURER'S DATA

FOR SPACING REQUIREMENTS

(TYPICAL ALL LOCATIONS AND SPACING)

REFER TO DETAIL "B"

THIS SHEET

REFER TO DETAIL "B"

THIS SHEET

REFER TO DETAIL "D"

THIS SHEET

REFER TO

DETAIL "A"

THIS SHEET

ADDITIONAL

COLLECTORS MAY

BE INTERCONNECTED

AS REQUIRED

ADDITIONAL

COLLECTORS MAY

BE INTERCONNECTED

AS REQUIRED

REFER TO DETAIL "A"

THIS SHEET

SOLAR

COLLECTOR

ADDITIONAL COLLECTORS MAY

BE INTERCONNECTED AS REQUIRED

REFER TO DETAIL "C"

THIS SHEET

REFER TO DETAIL "C"

THIS SHEET

ADDITIONAL COLLECTORS MAY

BE INTERCONNECTED AS REQUIRED

REFER TO MANUFACTURER'S DATA

FOR SPACING REQUIREMENTS

(TYPICAL ALL LOCATIONS AND SPACING)

GENERAL NOTES:

1.

2.

THREADED ROD OR ANCHOR BOLT, AS WELL

AS ROOF SUPPORT STRUCTURE, IS SUPPLIED

AND INSTALLED BY OTHERS. REFER TO

STRUCTURAL OR ARCHITECTURAL PLANS

FOR INSTALLATION DETAILS.

PLUMBING CONTRACTOR SHALL COORDINATE

EXACT LOCATION AND LENGTH REQUIREMENTS

OF THREADED RODS OR ANCHOR BOLTS

WITH OTHER TRADES, AND ACCORDING TO

MANUFACTURER'S RECOMMENDATIONS.

3. ALL EXTERIOR HEAT TRANSFER FLUID

PIPING PENETRATIONS AND THOSE MADE

INTO ROOMS DESIGNATED AS SCIF'S, SHALL

HAVE A DIELECTRIC FITTING PER JSOC

STANDARDS.

UTILIZE NON-PENETRATING

ROOF MOUNTS OR CLIPS

AS REQUIRED

UTILIZE NON-PENETRATING

ROOF MOUNTS OR CLIPS

AS REQUIRED

UTILIZE NON-PENETRATING

ROOF MOUNTS OR CLIPS

AS REQUIRED

UTILIZE NON-PENETRATING

ROOF MOUNTS OR CLIPS

AS REQUIRED

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

P-502

PL

U

M

BI

N G

D

ET

AI

LS

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-A

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

SCALE:NOT TO SCALEP-502

�� ���������
�������

P -5 .D W G

SCALE:NOT TO SCALEP-502

M

AR

K D

ES

C

R

IP

TI

O

N D

BATTALION BUILDING - DOMESTIC PLUMBING SYSTEM CALCULATIONS

DOMESTIC WATER FIXTURES

DESCRIPTION QUANTITY

COLD WATER TOTAL WATER SANITARY

FU TOTAL FU TOTAL DFU TOTAL

EWC 1 0.25 0.25 0.25 0.25 0.5 0.5

MOP SINK 1 2.25 2.25 3 3 2 2

LAVATORY, PUBLIC 7 1.5 10.5 2 14 1 7

BREAK SINK 1 3 3 4 4 2 2

SHOWER 2 3 6 4 8 3 6

URINAL, FV, PUBLIC 2 5 10 5 10 4 8

WATER CLOSET, FV, PUBLIC 6 10 60 10 60 4 24

WSFU(FIXTURES) = 92 WSFU(BLDG) = 99.25 DFU(BLDG) = 49.5

GPM(PER WSFU) =

GPM(HIGH) - GPM(LOW)

WSFU(HIGH) - WSFU(LOW)

67.5 - 64.3

100-90 = 0.32

67.5 - 64.3

100-90 = 0.32

WSFU = WSFU(FIXTURES) - WSFU(LOW) 92 - 90 = 2.0 92 - 90 = 9.3

GPM = WSFU X GPM(PER WSFU) 2 X .32 = 0.6 2 X .32 = 3.0

GPM(FIXTURES) = GPM(LOW) + GPM 64.3 + .6 = 64.94 GPM(BLDG) = 67.26

WATER

SELECTED PIPE SIZE: 2-1/2"

WATER VELOCITY (APPROXIMATE): 6 FPS

PRESSURE DROP PER 100 FEET (APPROXIMATE): 5 PSI

WASTE

SELECTED PIPE SIZE: 4"

PIPE SLOPE: 1/8"/FT

NOTES:

1. FIXTURES UNITS, WATER VELOCITY, AND PRESSURE DROP ARE CALCULATED PER NCBC-PLUMBING, LATEST EDITION.

2. PIPING SIZED PER TABLE 709.1, TABLE 709.2, TABLE 710.1(1), AND TABLE 710.1(2), NCBA - PLUMBING, LATEST EDITION. GENERAL EQUIPMENT SCHEDULE

ITEM

FIXTURE

DESCRIPTION

ADA

(Y/N)

POTABLE WATER

CONNECTIONS

WASTE AND VENT

CONNECTIONS

COLD HOT WASTE VENT

CO-1 CLEANOUT - - - 3" -

CO-2 CLEANOUT - - - 4" -

FD-1 FLOOR DRAIN - 1/2" - 3" -

FD-3 FLOOR DRAIN - - - 4" -

PLUMBING FIXTURE SCHEDULE

ITEM

FIXTURE

DESCRIPTION

ADA

(Y/N)

POTABLE WATER

CONNECTIONS

WASTE AND VENT

CONNECTIONS

COLD HOT WASTE VENT

EWC-1

ELECTRIC WATER

COOLER

Y 1/2" - 2" 2"

L-1

LAVATORY Y 1/2" 1/2" 1-1/2" 2"

MOP SINK - 1/2" 1/2' 3" 2"

SH-1

SHOWER

HEAD/FAUCET

Y 1/2" 1/2"

SINK - 1/2" 1/2" 1-1/2" 2"

URINAL Y 3/4" - 2" 2"

WC-1

WATER CLOSET - 1" - 4" 2"

WATER CLOSET Y 1" - 4" 2"

WALL MOUNTED, HI/LO WITH BOTTLER FILLER

VITREOUS CHINA, WALL MOUNTED

MOLDED STONE, 24 X 24 X 10, 3" INTEGRAL DRAIN

CHROME PLATED, PRESURE BALANCING VALVE WITH 1/4

TURN STOPS, 3 FUNCTION TRANSFER VALVE, 1.5 GPM

STAINLESS STEEL, 18 GA, DROP-IN

VITREOUS CHINA, WALL MOUNTED, WASHOUT, 0.125 GPF

VITREOUS CHINA, FLOOR MOUNTED, 1.28 GPF

VITREOUS CHINA, FLOOR MOUNTED, 1.28 GPF

FLUSH VALVE - 1" -MANUAL FLUSH VALVE

FLUSH VALVE - 1" -MANUAL FLUSH VALVE

WC-2

UR-1

FLUSH VALVE MANUAL FLUSH VALVE - 3/4" - - -

FAUCET

SK-1

MS-1

FAUCET

FAUCET

CHROME PLATED, W/VACUUM BREAKER, INTEGRAL STOPS - - - -

- -1/2" 1/2"

1/2"

1/2" 1/2"

DRAIN

DURA-COATED CAST IRON BODY, ADJUSTABLE COLLAR

WITH SEEPAGE SLOTS

Y

BRASS CONSTRUCTION, QUARTER-TURN, AERATED FLOW,

LEVER HANDLES

CHROME, LEVEL HANDLE, DECK MOUNT

3"- 2"-

DURA-COATED CAST IRON BODY, WITH GAS AND WATER

TIGHT THREADED ABS PLUG

DURA-COATED CAST IRON BODY, ADJUSTABLE COLLAR

WITH SEEPAGE SLOTS

DURA-COATED CAST IRON BODY, ADJUSTABLE COLLAR

WITH SEEPAGE SLOTS, TRAP PRIMER CONNECTION

DURA-COATED CAST IRON BODY, WITH GAS AND WATER

TIGHT THREADED ABS PLUG

ICE-1 ICE MACHINE QTR-TURN VALVE, 1/2" SWEAT CONNECTION W/ARRESTOR

FD-2 FLOOR DRAIN - - 3" -

DURA-COATED CAST IRON BODY, ADJUSTABLE COLLAR

WITH SEEPAGE SLOTS

WHA-1

WATER HAMMER

ARRESTOR

- 1/2" - -

COPPER BODY, POLYPROPYLENE PISTON, LEAD FREE

BRASS THREADED ADAPTER

WHA-2

WATER HAMMER

ARRESTOR

- 1" - -

1/2" -

COPPER BODY, POLYPROPYLENE PISTON, LEAD FREE

BRASS THREADED ADAPTER

EQUIPMENT SCHEDULE

ITEM

FIXTURE

DESCRIPTION

ADA

(Y/N)

POTABLE WATER

CONNECTIONS

WASTE AND VENT

CONNECTIONS

COLD HOT WASTE VENT

EWH-1

ELECTRIC WATER

HEATER

- 1-1/2" 1-1/2" - -

ET-1 EXPANSION TANK - 3/4" - - -

PUMP-1

DOMESTIC WATER

RECIRCULATION PUMP

- - 1-1/4" - -

BFP-1

BACKFLOW PREVENTER

(DOUBLE CHECK)

- 2-1/2" - - -

BFP-2

BACKFLOW PREVENTER

(RPZ) - 1" - - -

ST-1 SOLAR WATER TANK - - -

SP-1 SOLAR PANEL - - -

1-1/2" 1-1/2"

1-1/2" 1-1/2"

121.56" X 47.56" DOUBLE-STRENGTH TEMPERED LOW IRON

SOLAR GLASS, 2.8" THICK PROFILE, 1.3 GAL FLUID CAPACITY

80 GAL INSULATED JACKET

CAST COPPER BODY, LEAD FREE, QUARTER-TURN

BALL VALVES, MAX 175 PSI

115 VAC, SINGLE PHASE, 1/25 HP, 10 GPM

@ 5' HEAD

5 GAL, FIELD ADJUSTABLE 40 PSI AIR CHARGE,

BUTYL DIAPHRAGM, MAX PRESSURE 150 PSI

120 GAL, COMMERICAL ELECTRIC 24 KW, 208V/3� @ 100°F RISE,

150 WORKING PRESSURE

EPOXY COATED CAST IRON WITH STRAINER, LEAD

FREE CAST COPPER BALL VALVE, MAX 175 PSI

HE-1 HEAT EXCHANGER - - -1-1/2" 1-1/2"

MOUNTABLE, CLOSED LOOP,DOUBLE WALL, 2 GAL

SYSTEM EXPANSION TANK, 110VAC, 60 HZ

EQUIPMENT SPECIFICATION

EQUIPMENT DESCRIPTION

EQUIPMENT DESCRIPTION

MV-1 MIXING VALVE - - -1-1/2" 1-1/2"

LEAD FREE BRASS BODY CONSTRUCTION, LEAD FREE MIXING

VALVES, VANDAL-RESISTANT, 180°F MAX TEMP, 125 PSIG MAX

TPV-1

TRAP PRIMER

VALVE

- - -360 BRASS, MAXIMUM PRESSURE 80 PSI -1/2"

BATTALION BUILDING - DOMESTIC WATER HEATER CALCULATION

DOMESTIC HOT WATER FIXTURES

HOT WATER GALLONS PER FIXTURE

HOUR

TOTAL GALLONS PER

FIXTURE PER HOURFU

1 2.25 2.25 20 20

7 1.5 10.5 6 42

1 3 3 20 20

2 3 6 30 60

WSFU(FIXTURES) = 21.75 GPH @140°F(TOTAL) = 142

21.5 - 19.6

25 - 20 = 0.38

21.75 - 20 = 1.75

1.8 X .38 = 0.66

19.6 + .66 = 20.3

GALLONS PER HR @140°F(TOTAL): TOTAL: 142

DEMAND FACTOR: 0.3

ADJUSTED GALLONS PER HOUR : 0.3 x GALLONS PER HR @140°F 0.3 x 142 = 43

STORAGE CAPACITY FACTOR: 2

TOTAL STORAGE CAPACITY FACTOR: 2 x ADJUSTED GALLONS PER HOUR 2 x 43 = 85.2

WATER

SELECTED PIPE SIZE: 1-1/2"

WATER VELOCITY (APPROXIMATE): 5 FPS

PRESSURE DROP PER 100 FEET (APPROXIMATE): 5 PSI

TOTAL:

TOTAL:

DESCRIPTION

MOP SINK

LAVATORY, PUBLIC

BREAK SINK

SHOWER

GPM(PER WSFU) =

GPM(HIGH) - GPM(LOW)

WSFU(HIGH) - WSFU(LOW)

WSFU = WSFU(FIXTURES) - WSFU(LOW)

GPM = WSFU X GPM(PER WSFU)

GPM(FIXTURES) = GPM(LOW) + GPM

QUANTITY

TOTAL

PLUMBING/ELECTRICAL EQUIPMENT SCHEDULE

EQUIPMENT

DESIGNATION

EQUIPMENT

DESCRIPTION

EQUIPMENT

FURNISHED BY

VOLTAGE/

PHASE

KW HP

DISCONNECT

FURNISHED BY

STARTER

FURNISHED BY

CONTROLS REMARKS

EWC-1

ELECTRIC

WATER COOLER

CONTRACTOR 115V .37KW CONTRACTOR N/A W/EQUIP-

EWH-1

ELECTRIC

WATER HEATER

CONTRACTOR 208V/3 24KW CONTRACTOR N/A W/EQUIP-

PUMP-1

HOT WATER

RECIRC PUMP

CONTRACTOR 115V/1 .11KW CONTRACTOR N/A W/EQUIP1/25

HE-1

HEAT

EXCHANGER

CONTRACTOR 110V/1 .06KW CONTRACTOR N/A W/EQUIP-

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

P-601

PL

U

M

BI

N G

S C

H

ED

U

LE

S

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-A

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

P -6 .D W G

M

AR

K D

ES

C

R

IP

TI

O

N D

1/2" D

CW

1 1/4" DHW

1" DCW

2" D C

W

1" D H

W

2 1/2" D

CW 1 1/2" D

HW

3/4" DH

W

R

3/4" DHW

2" DCW

3/4"

3/4" DHWR

3/4" DHW

1/2" DCW

1 1/2" DCW

1/2" DCW

1/2" DHW

1/2" DHW

1/2" DCW

1/2"DCW & 1/2"DHW

WITH BALL VALVE AND

WATER HAMMER

ARRESTOR (WHA-1)

(TYP. 10)

1/2"

1/2"

1"

1/2" DHW

1/2" DCW

SH-1

SH-1

WC-2

WC-2

L-1 L-1

L-1

L-1

L-1

L-1

UR-1

UR-1

WC-1

WC-1

WC-2

WC-2

MS-1

1"DCW WITH SHUT-

OFF VALVE AND

WATER HAMMER

ARRESTOR(WHA-2)

(TYP .2)

1 1/2" DCW

EWC-1

1/2"DCW & 1/2"DHW

WITH BALL VALVE AND

WATER HAMMER

ARRESTOR (WHA-1)

(TYP. 8)

1"DCW WITH SHUT-

OFF VALVE AND

WATER HAMMER

ARRESTOR (WHA-2)

(TYP. 2)

SHUT-OFF VALVE

CHECK VALVE

CIRCUIT SETTER

SHUT-OFF VALVE

SHUT-OFF VALVE

CHECK VALVE

CIRCUIT SETTER

SHUT-OFF VALVE

1 1/2" D

HW

2" D C

W

L-1

2" DCW

1"

1"

1 1/2"

1 1/2"

1"

1"

1/2"

1/2"

1"

3/4"

1"

3/4"

1"

1" 1/2"

1/2"

CONNECT 1/2"DCW TO

FLOOR DRAIN(FD-1)

CONNECT 1/2"DCW TO

FLOOR DRAIN(FD-1)

1/2"

1/2" DHW

1/2" DCW

TPV-1

1/2" DHW

1/2" DCW

1/2" DHW

TPV-1

CONNECT 1/2"DCW TO

FLOOR DRAIN(FD-1)

CONNECT 1/2"DCW TO

FLOOR DRAIN(FD-1)

CONNECT 1/2"DCW TO

FLOOR DRAIN(FD-1)

TPV-1

1/2"

SK-1

ICE-1 1/2" DHW

1/2" DCW

3/4" DHWR

1/2" DCW

3/4" DHW

3/4" DHWR

3/4" DHW

1/2" DCW

1/2" DCW

EWH-1

ET-1

1"DCW TO MECHANICAL

EQUIPMENT. REFER TO

MECHANICAL DRAWINGS

FOR DETAIL

SHUT-OFF VALVE

HOT WATER RECIR. PUMP

CHECK VALVE

SHUT-OFF VALVE

ST-1

SOLAR SUPPLY AND

RETURN UP TO SOLAR

PANELS ON ROOF

BFP-1

BFP-2

2 1/2" DCW

1 1/2" SWS

1 1/2" SWR

3/4" DHWR

2 1/2" DCW

1 1/2" DHW

2 1/2" DCW

HE-1

ET-1

MV-1

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

P-901

PL

U

M

BI

N G

R

IS

ER

D

IA

G

R

AM

S

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-A

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

SCALE: NOT TO SCALEP-901

D1 WATER DISTRIBUTION RISER DIAGRAM - MECHANICAL ROOM/BATHROOM GROUP

A3

P-901

SCALE: NOT TO SCALEP-901

A3 WATER DISTRIBUTION RISER DIAGRAM - BREAK ROOM/JANITOR

D1

P-901

SCALE: NOT TO SCALEP-901

D7 WATER HEATER AND SOLAR STORAGE TANK PIPING

D1

P-901

REFER

CIVIL

D7

P-901

P -9 .D W G

M

AR

K D

ES

C

R

IP

TI

O

N D

V

2" V

2" V

2" V

2" V

V

2" V

2" V

4" S

AN

4" SAN

3" SAN

4" SAN

3" SAN

2" SAN

4" SAN

3" SAN

2" SAN

4" SAN

FD-1

FD-1

FD-1

SH-1

SH-1

FD-1

FD-1

L-1

L-1

L-1

2" SAN

4" SAN

V

V

V

V

V

V 2

V

V

3" V

2" V

L-1

L-1

L-1

L-1

UR-1

UR-1

CO-1

WC-2

WC-2

WC-1

4" SAN

WC-2

WC-2

4" S

AN

4" SAN

4" SAN

4" SAN

FD-3

FD-3FD-3

MS-1

CO-2

FD-3

V

2" V

2" V

V

EWC-1

2" SAN

3"V UP

TO VTR

3" SAN

CO-2

3" SAN

V

2" V

2" V

FD-3

CO-2

4" SAN

V

4" S

AN

FD-2

CO-1

3" S

AN

3" SAN

3" SAN

3" SAN

V

SK-1

2"V UP

TO VTR

FD-2

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

P-902

PL

U

M

BI

N G

R

IS

ER

D

IA

G

R

AM

S

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-A

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

SCALE: NOT TO SCALEP-902

D5 WASTE AND VENT RISER DIAGRAM - MECHANICAL ROOM/JANITOR/BATHROOM GROUP

A3

P-902

SCALE: NOT TO SCALEP-902

A3 WASTE AND VENT RISER DIAGRAM - CORRIODR/BREAK ROOM

D5

P-902

REFER

CIVIL

P -9 .D W G

M

AR

K D

ES

C

R

IP

TI

O

N D

SYMBOLS DEFINITION

ABBREVIATION DEFINITION ABBREVIATION DEFINITION

SYMBOLS DEFINITION

LEGEND AND ABBREVIATIONS

ASPE

ATM

BTUH

CONT

CO

DCW

DEG

FCO

GAL

GC

GPM

H

HD

DHW

DHWR

IN

IN

IN

IPS

L

DIA

EL

AFF

FT

FU

ANSI

ASME

GPH

AMP

AGA

AG

HGT

HP

FF

FL

EC

BTU

FT

FT

N C

N O

N/A

NFPA

NIC

NTS

NO

OZ

PC

PRV

PSI

R

RDL

RPZ

LB

LBS

OD

AMERICAN SOCIETY OF PLUMBING ENGINEERS

ATMOSPHERE

BRITISH THERMAL UNITS PER HOUR

CONTINUED

CLEANOUT

DOMESTIC COLD WATER

DEGREE

FLOOR CLEANOUT

GALLON

GENERAL CONTRACTOR

GALLON PER MINUTE

HYDROGEN

HEAD

DOMESTIC HOT WATER

DOMESTIC HOT WATER RETURN

INCH/INCHES

SQUARE INCH(ES)

CUBIC INCH(ES)

IRON PIPE SIZE

LENGTH

DIAMETER

ELEVATION

ABOVE FINISHED FLOOR

FOOT/FEET

FIXTURE UNIT

AMERICAN NATIONAL STANDARDS INSTITUTE

AMERICAN SOCIETY OF MECHANICAL ENGINEERS

GALLON PER HOUR

AMPERE

AMERICAN GAS ASSOCIATION

ABOVE GROUND

HEIGHT

HORSEPOWER

FINISHED FLOOR

FLOOR

ELECTRICAL CONTRACTOR

BRITISH THERMAL UNITS

SQUARE FOOT/FEET

CUBIC FOOT/FEET

NORMALLY CLOSED

NORMALLY OPEN

NOT APPLICABLE

NATIONAL FIRE PROTECTION ASSOCIATION

NOT IN CONTRACT

NOT TO SCALE

NUMBER

OUNCE(S)

PLUMBING CONTRACTOR

PRESSURE REDUCING VALVE

POUNDS PER SQUARE INCH

THERMAL RESISTANCE

ROOF DRAIN LEADER

REDUCED PRESSURE ZONE

POUND

POUNDS

OVERFLOW DRAIN

FFE FINISHED FLOOR ELEVATION

HR HOUR

MIN MINUTE

NPS NOMINAL PIPE SIZE

DC DOUBLE CHECK

A ARGON

CA COMPRESSED AIR

CL CHLORINE

CIP CAST IRON PIPE

CISPI CAST IRON SOIL AND PIPE INSTITUTE

DIP DUCTILE IRON PIPE

CU COPPER

DI DE-IONIZED WATER

MA MEDICAL AIR

F FLUORINE

HE HELIUM

HG MERCURY

LPG LIQUIFIED PETROLEUM GAS

N NITROGEN

NG NATURAL GAS

N2O NITROUS OXIDE

OX OXYGEN

POC POINT OF CONNECTION

AHJ AUTHORITY HAVING JURISDICTION

EQUIPMENT DESIGNATION

EXTERIOR CLEANOUT

HOSE BIBB

INTERIOR FLOOR CLEANOUT

MIXING VALVE

UNION

WALL CLEANOUT

TEMPERATURE & PRESSURE RELIEF VALVE

DOUBLE CHECK BACKFLOW PREVENTER

CHECK VALVE

BALL VALVE

ROOF DRAIN

PUMP

TRAP PRIMER VALVE

FLOOR SINK

FLOOR DRAIN

POINT OF CONNECTION TO EXISTING

REDUCED PRESSURE ZONE BACKFLOW PREVENTER

WATER HAMMER ARRESTOR

CIRCUIT SETTER

SYMBOLS DEFINITION

DETAIL CALLOUT

REVISION CALLOUT

KEYNOTE T AG

IE INVERT ELEVATION

FD FLOOR DRAIN

AD AREA DRAIN

FS FLOOR SINK

REFER

SANITARY

DOMESTIC COLD WATER

DOMESTIC HOT WATER RETURN

DOMESTIC HOT WATERDHW

DHWR

SAN

DCW

LINETYPES DEFINITIONS

SANITARY VENTV

SOLAR WATER SUPPLY

SOLAR WATER RETURNSWR

SWS

LINETYPES DEFINITIONS

SPEC

SQ

SS

SAN

STD

T

TEMP

UG

UL

VERT

VTR

WCO

WHA

W

SPECIFICATION(S)

SQUARE

STAINLESS STEEL

SANITARY SEWER

STANDARD

TEMPERATURE

TEMPERATURE DIFFERENCE

UNDERGROUND

UNDERWRITERS LABORATORIES

VERTICAL

VENT THROUGH ROOF

WALL CLEANOUT

WATER HAMMER ARRESTOR

WIDTH

SEC SECOND

VAC VACUUM

WT WEIGHT

V SANITARY VENT

VIV VALVE IN VERTICAL

TW TEMPERED WATER

SIM SIMILAR

TD TRENCH DRAIN

X EXISTING

TPV TRAP PRIMER VALVE

SPG SPECIALTY GAS

TYP TYPICAL

WC WATER CLOSET

UR URINAL

SWS SOLAR WATER SUPPLY

SWR SOLAR WATER RETURN

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

P-001

PL

U

M

BI

N G

S

YM

BO

LS

A

BB

R

EV

IA

TI

O

N S

-B

ID

O

PT

IO

N

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-B

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

P -0 .D W G

M

AR

K D

ES

C

R

IP

TI

O

N D

PL402

1 1. 1 2 3 3.6 4 5 5.8 6 5.7

G

F.9

F.1

F

E

C

B.8

B.1

B

A

4.2 1.2 5.1

D

PL402

STAFF DUTY

CHAPLAIN

ASSISTANT

CORRIDOR

CORRIDOR

OPEN OFFICE

117WOMEN

MEN

S-4

S-2

ELEC

129 VEST

MECHANICAL

BREAKROOM

LOBBY

RE-ENLISTMENT

EO

VEST

CHAPLAIN

SHARP

137 XO

BRIGADE

COMMANDER

SGT MAJOR

RECEPTION

VESTIBULE

CORRIDOR

OPEN OFFICE

SUPPLY

STORAGE

LACTATION

CUSTODIAL

FILE STORAGE

OF LEGAL SUITE

121LEGAL

DOCUMENT

STORAGE

123COMM

CORRIDOR

114 CONF TEAM

ROOM

S-3

S-1

CONFERENCE

1-HOUR RATED FIRE PARTITION

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

N

AO

F

IL

E N

O

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

JA

N

U

AR

Y

W

4B

W

4C

D R

R

D R

R

K.

B

R O

D

BE

R

PL101

FI

R

ST

F

LO

O

R

PL

U

M

BI

N G

W

AS

TE

A

N D

V

EN

T

PL

AN

BI

D

O

PT

IO

N

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

R

EE

T

N O

R

FO

R K, V

IR

G

IN

IA

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

RA

LE

IG

H, N C

6-

(9

) 8

-6

(9

) 8

-7

FA

X

LI

CE

NS

E

F-

JO

IN

T

BA

SE

L

AN

G

LE

Y-

EU

ST

IS

(E

U

ST

IS

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-H

Q

PR

O

JE

C T

N U

M

BE

R : 7

HQ-B

BW

READY TO ADVERTISE (RTA)

ISSUED FOR CONSTRUCTION

0 4 8 16'

1/8" = 1'-0"

N

PLAN NORTH

SCALE: 1/8" = 1'-0"A2 FIRST FLOOR - PLUMBING WASTE AND VENT PLAN

P L .D W G

GENERAL NOTE:

1. SEAL ALL PENETRATIONS THROUGH PARTITIONS WITH STC

RE…

This is the start of the file's text. The full file is on GovTribe.