VOL_3_P-001_20May2016.pdf

PDF 25 KB Posted

Attached to
AIT Barracks- Phase III, Ft. Lee, Virginia Federal contract opportunity
Solicitation number
W91236-16-R-0010
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

Volume 3 P-001 20May2016

View the file

Other files for this federal contract opportunity

Other files attached to AIT Barracks- Phase III, Ft. Lee, Virginia, newest first.
File Type Posted
W91236-16-R-0010-0008.pdf PDF
VOL_2_A-601_3JUN2016.pdf PDF
VOL_2_EP104_3JUN2016.pdf PDF
VOL_2_EP601_3JUN2016.pdf PDF
VOL_2_EP703_3JUN2016.pdf PDF
VOL_3_EP701_3JUN2016.pdf PDF
VOL_2_M-001_3JUN2016.pdf PDF
VOL_3_EL502_3JUN2016.pdf PDF
VOL_3_EP102_3JUN2016.pdf PDF
W91236-16-R-0010-0005.pdf PDF
VOL_3_A-601_3JUN2016.pdf PDF
Hazard_Assessment_Survey_2013.pdf PDF
VOL_4_QF603_3JUN2016.pdf PDF
VOL_4_QF512_3JUN2016.pdf PDF
VOL_2_M-602_3JUN2016.pdf PDF
VOL_2_EL502_3JUN2016.pdf PDF
VOL_2_EL701_3JUN2016.pdf PDF
Am_4_-_Attach_17_VOL_3_S-102_26MAY2016.pdf PDF
Am_4_-_Attach_12_VOL_3_A-318_26MAY2016.pdf PDF
W91236-16-R-0010-0004.pdf PDF
25May2016_Site_Visit_Roster.pdf PDF
Am_4_-_Attach_01_VOL_1__CS101-103_26MAY2016.pdf PDF
Am_4_-_Attach_06_VOL_2_A-551_26MAY2016.pdf PDF
Am_4_-_Attach_19_VOL_3_S-105A_26MAY2016.pdf PDF
Am_4_-_Attach_24_VOL_4_A-103_26MAY2016.pdf PDF
Am_4_-_Attach_14_VOL_3_A-551_26MAY2016.pdf PDF
Am_4_-_Attach_09_VOL_2_S-108_26MAY2016.pdf PDF
Am_4_-_Attach_25_VOL_4_A-510_26MAY2016.pdf PDF
Am_4_-_Attach_11_VOL_3_A-112_26MAY2016.pdf PDF
Am_4_-_Attach_16_VOL_3_S-003_26MAY2016.pdf PDF
Am_4_-_Attach_10_VOL_3_A-101_26MAY2016.pdf PDF
Am_4_-_Attach_08_VOL_2_S-003_26MAY2016.pdf PDF
W91236-16-R-0010-0003.pdf PDF
VOL 1_LEE_SITE_20May2016.pdf PDF
Utility_Coordination_20May2016.pdf PDF
01_33_29_20May2016.pdf PDF
BARRACKS_SPECS_VOL2_16May2016.pdf PDF
DFAC_SPECS_VOL1_16May2016.zip ZIP file
BARRACKS_SPECS_VOL3_16May2016.pdf PDF
W91236-16-R-0010-0002.pdf PDF
BARRACKS_SPECS_VOL1_16May2016.pdf PDF
VOL 2_LEE_BCOF_600_16May2016.pdf PDF
VOL 3_LEE_BCOF_300_16May2016.pdf PDF
W91236-16-R-0010-00001.pdf PDF
H.01.04__Drainage_Report_21April2016.zip ZIP file
H.01.04_Volume2600PersonBarracks_21April2016.zip ZIP file
H.01.04_LEE_VOLUME_3_300MAN_(ProgressSubmission).zip ZIP file
H.01.04_LEE_VOLUME_2_600_MAN_BARRACKS(Progress_Submission).zip ZIP file
H.01.04_Volume1SITEPlans_21April2016.zip ZIP file
H.01.04_LEE_VOLUME_4_DFAC_(ProgressSubmission).zip ZIP file
Show all 50

AIT Barracks- Phase III, Ft. Lee, Virginia has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADA AMERICAN DISABILITY ACT

BFF BELOW FINISHED FLOOR

BOP BOTTOM OF PIPE

CW COLD WATER

DIA DIAMETER

DSN DOWNSPOUT NOZZLE

FCO FLOOR CLEAN OUT

FS FLOOR SINK

GPF GALLONS PER FLUSH

GPM GALLONS PER MINUTE

HP HORSEPOWER

HW HOT WATER

IV ISOLATION VALVE

ODUS OLD DOMINION UTILITY SERVICES

RC HOT WATER RECIRCULATION

RPBP REDUCED PRESSURE BACKFLOW PREVENTER

RPM REVOLUTIONS PER MINUTE

SS STAINLESS STEEL

STR STORM PIPING

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

V VENT

VTR VENT THROUGH ROOF

WCO WALL CLEAN OUT

WH WALL HYDRANT

WHA 'A' WATER HAMMER ARRESTOR AND SIZE

120 DOMESTIC HOT WATER (120 F)

ABBREVIATIONS

GENERAL NOTES

1. COORDINATE WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING IN PLUMBING

CONNECTIONS.

2. PROTECT COPPER PIPING AGAINST CONTACT WITH MASONRY OR DISSIMILAR METALS,

HANGERS, SUPPORTS, ANCHORS AND CLIPS SHALL BE COPPER OR COPPER PLATED.

3. WATER RISERS SHALL BE INSTALLED ON THE CONDITIONED SPACE SIDE OF THE

BUILDING THERMAL INSULATION.

4. ALL PLUMBING VENTS WITHIN A 15'-0" RADIUS OF ANY ROOF TOP UNIT OR FRESH AIR

INTAKE SHALL BE OFFSET TO CLEAR OUTSIDE THE RADIUS.

5. ALL SANITARY, LINT WASTE AND RAINLEADER PIPING SHALL BE GRADED

DOWNWARD IN THE DIRECTION OF FLOW AT 1/8" PER FOOT FOR PIPING 3" AND

LARGER, AND 1/4" PER FOOT FOR PIPING 2 1/2" OR LESS UNLESS NOTED OTHERWISE.

WASTE PIPING LOCATED BELOW GRADE SHALL BE CAST IRON.

6. STORM, VENT, AND SANITARY ARE SHOWN ON PLANS LABELED SANITARY. DOMESTIC

WATER AND NATURAL GAS ARE SHOWN ON PLANS LABELED PLUMBING.

7. ALL FLOOR DRAINS SHALL BE EQUIPPED WITH TRAP PRIMERS. TRAP PRIMERS HAVE

ONLY BEEN SHOWN FOR THE MECHANICAL CLOSETS DUE TO THE REMOTENESS OF

THE WATER LINES.

LEGEND

CONSTRUCTION NOTE IDENTIFICATION

ROOM NUMBER DESIGNATION

DOMESTIC COLD WATER

DOMESTIC HOT WATER

STORM DRAINAGE PIPING

NATURAL GAS PIPING

SOIL, WASTE OR SANITARY SEWER

VENT PIPING

PIPE TURNING UP

PIPE TURNING DOWN

TOP CONNECTION

BOTTOM CONNECTION

WALL CLEANOUT

CLEANOUT, FLOOR TYPE

FLOOR DRAIN WITH DEEP SEAL P-TRAP

WALL HYDRANT (FROST PROOF)

DIRECTION OF FLOW

PRESSURE RELIEF VALVE

BACKFLOW PREVENTER (BFP)

BALL VALVE

CHECK VALVE

PRESSURE GAUGE

THERMOMETER

UNION

VACUUM BREAKER

WATER HAMMER ARRESTOR - "X" INDICATES SIZE

FLOW CONTROL VALVE (FCV)

STR

WCO

FCO

FD

WH

WHA-X

G

BFP

ELEVATION, SECTION OR DETAIL SYMBOL

SHEET NUMBER WHERE ELEVATION,

SECTION OR DETAIL IS DRAWN

NUMBER INDICATES SECTION

LETTER INDICATES ELEVATION OR DETAIL

P-401

SHEET NUMBER WHERE ELEVATION,

SECTION OR DETAIL IS TAKEN

NUMBER INDICATES SECTION

LETTER INDICATES ELEVATION OR DETAIL

P-101

NOTES:

1. LOW NOx TYPE (<30 PPM @ 3% O2).

NOTES:

1. REFER TO CIVIL SHEETS FOR LOCATION.

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

280154

P-001

VOLUME 3

PL

U

M

BI

N G

L

EG

E N D

, A

BB

R

EV

IA

TI

O N

S, A

N D

N O

TE

S

A

IT

B A

R

RA

CK

S

CO

M

PL

EX

PH

A

SE

3 0

M

A N

N O

R

FO

LK

D

I S

TR

IC

T

N O

R

FO

LK

, V

A

SA

G

EA

M

D

AG

M

LM

A

PR

PR

O

JE

C T

N U

M

BE

R

C O

N

TR

AC

T

N O

P- 0 0

1-

F O R

T L E

E, V

I R G

IN

I A

STORAGE TANK

MARK LOCATION

DIAMETER

(IN)

VOLUME

(GAL)

ST-1 MECHANICAL ROOM 90" 2850

ST-2 MECHANICAL ROOM 90" 2850

ST-3 MECHANICAL ROOM 90" 2850

PLUMBING FIXTURE SCHEDULE

MARK FIXTURE MOUNTING CW HW WASTE VENT

P-1 WATER CLOSET FLOOR 1" - 3" 2"

P-2 WATER CLOSET (ADA) FLOOR 1" - 3" 2"

P-3 URINAL WALL 3/4" - 2" 1 1/2"

P-4 LAVATORY COUNTERTOP 1/2" 1/2" 1 1/2" 1 1/4"

P-5 SHOWER FLOOR / FITTING FLOOR / WALL 1/2" 1/2" 2" 1 1/2"

P-6 WATER COOLER WALL 1/2" - 1 1/2" 1 1/4"

P-7 MOP SINK WALL 3/4" 3/4" 3" 1 1/2"

P-8 WASHMACHINE BOX WALL 1/2" 1/2" 2" 1 1/2"

P-9 UTILITY SINK WALL 3/4" 3/4" 3" 1 1/2"

P-10 KITCHEN SINK COUNTERTOP 1/2" 1/2" 2" 1 1/2"

P-11 ICE MACHINE WALL 1/2" - - -

WATER HEATER SCHEDULE

MARK LOCATION

MBH

INPUT

THERMAL

EFFICIENCY

RECOVERY RATE GPH

(40F TO 100F) ELECTRICAL

WH-1 MECHANICAL ROOM 1300 96% 1513 120/60/1

DRAIN SCHEDULE

MARK SERVICE

OVERALL

DIAMETER (IN) SHAPE WASTE

DD FLOOR & SHOWER

FD-1 FLOOR & SHOWER 6" ROUND 2"

FD-2 FLOOR & SHOWER 6" ROUND 4"

OD-1 OVERFLOW ROOF DRAIN 8" ROUND 4"

RD-1 ROOF DRAIN 8" ROUND 4"

TD-1 TRENCH DRAIN - RECTANGULAR 3"

MIXING VALVE

MARK MIN FLOW (GPM) MAX FLOW (GPM) PRESSURE DROP (PSI) TEMP SETTING (F)

MV-1 13 225 10 120

PUMP SCHEDULE

MARK SERVICE TYPE GPM PUMP TDH POWER (HP) ELECTRICAL NOTES

CP-1 HW RECIRC INLINE 13 10 1/6 115/1/60

CP-2 ELEVATOR SUMP SUMP 30 20 1/2 115/1/60 1

CP-3 WWHP INLINE 30 15 1/4 115/1/60

INTERCEPTOR SCHEDULE

MARK TYPE

CAPACITY

(GAL)

INLET/OUTLET

SIZE (IN) NOTES

SI-1 SAND & SEDIMENT INTERCEPTOR 300 2

LI-1 LINT INTERCEPTOR 2000 4 1

EXPANSION TANK SCHEDULE

MARK LOCATION TYPE ACCEPTANCE VOLUME (GAL)

ET-1 MECHANICAL ROOM BLADDER 211

NOTES:

1. PUMP REQUIRES TWO RECEPTACLES; ONE FOR THE CONTROL PANEL AND ONE FOR THE REMOTE ALARM.

NOTES:

1. FLOOR FOR P-5 SHALL BE 36" x 36".

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

P

ER

A

M

EN

D M

EN

T

M

AY

Sheets
P-001 - PLUMBING LEGEND, ABBREVIATIONS, AND NOTES

File details come from the government source that posted it. Updated .