ADA AMERICAN DISABILITY ACT
BFF BELOW FINISHED FLOOR
BOP BOTTOM OF PIPE
CW COLD WATER
DIA DIAMETER
DSN DOWNSPOUT NOZZLE
FCO FLOOR CLEAN OUT
FS FLOOR SINK
GPF GALLONS PER FLUSH
GPM GALLONS PER MINUTE
HP HORSEPOWER
HW HOT WATER
IV ISOLATION VALVE
ODUS OLD DOMINION UTILITY SERVICES
RC HOT WATER RECIRCULATION
RPBP REDUCED PRESSURE BACKFLOW PREVENTER
RPM REVOLUTIONS PER MINUTE
SS STAINLESS STEEL
STR STORM PIPING
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
V VENT
VTR VENT THROUGH ROOF
WCO WALL CLEAN OUT
WH WALL HYDRANT
WHA 'A' WATER HAMMER ARRESTOR AND SIZE
120 DOMESTIC HOT WATER (120 F)
ABBREVIATIONS
GENERAL NOTES
1. COORDINATE WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING IN PLUMBING
CONNECTIONS.
2. PROTECT COPPER PIPING AGAINST CONTACT WITH MASONRY OR DISSIMILAR METALS,
HANGERS, SUPPORTS, ANCHORS AND CLIPS SHALL BE COPPER OR COPPER PLATED.
3. WATER RISERS SHALL BE INSTALLED ON THE CONDITIONED SPACE SIDE OF THE
BUILDING THERMAL INSULATION.
4. ALL PLUMBING VENTS WITHIN A 15'-0" RADIUS OF ANY ROOF TOP UNIT OR FRESH AIR
INTAKE SHALL BE OFFSET TO CLEAR OUTSIDE THE RADIUS.
5. ALL SANITARY, LINT WASTE AND RAINLEADER PIPING SHALL BE GRADED
DOWNWARD IN THE DIRECTION OF FLOW AT 1/8" PER FOOT FOR PIPING 3" AND
LARGER, AND 1/4" PER FOOT FOR PIPING 2 1/2" OR LESS UNLESS NOTED OTHERWISE.
WASTE PIPING LOCATED BELOW GRADE SHALL BE CAST IRON.
6. STORM, VENT, AND SANITARY ARE SHOWN ON PLANS LABELED SANITARY. DOMESTIC
WATER AND NATURAL GAS ARE SHOWN ON PLANS LABELED PLUMBING.
7. ALL FLOOR DRAINS SHALL BE EQUIPPED WITH TRAP PRIMERS. TRAP PRIMERS HAVE
ONLY BEEN SHOWN FOR THE MECHANICAL CLOSETS DUE TO THE REMOTENESS OF
THE WATER LINES.
LEGEND
CONSTRUCTION NOTE IDENTIFICATION
ROOM NUMBER DESIGNATION
DOMESTIC COLD WATER
DOMESTIC HOT WATER
STORM DRAINAGE PIPING
NATURAL GAS PIPING
SOIL, WASTE OR SANITARY SEWER
VENT PIPING
PIPE TURNING UP
PIPE TURNING DOWN
TOP CONNECTION
BOTTOM CONNECTION
WALL CLEANOUT
CLEANOUT, FLOOR TYPE
FLOOR DRAIN WITH DEEP SEAL P-TRAP
WALL HYDRANT (FROST PROOF)
DIRECTION OF FLOW
PRESSURE RELIEF VALVE
BACKFLOW PREVENTER (BFP)
BALL VALVE
CHECK VALVE
PRESSURE GAUGE
THERMOMETER
UNION
VACUUM BREAKER
WATER HAMMER ARRESTOR - "X" INDICATES SIZE
FLOW CONTROL VALVE (FCV)
STR
WCO
FCO
FD
WH
WHA-X
G
BFP
ELEVATION, SECTION OR DETAIL SYMBOL
SHEET NUMBER WHERE ELEVATION,
SECTION OR DETAIL IS DRAWN
NUMBER INDICATES SECTION
LETTER INDICATES ELEVATION OR DETAIL
P-401
SHEET NUMBER WHERE ELEVATION,
SECTION OR DETAIL IS TAKEN
NUMBER INDICATES SECTION
LETTER INDICATES ELEVATION OR DETAIL
P-101
NOTES:
1. LOW NOx TYPE (<30 PPM @ 3% O2).
NOTES:
1. REFER TO CIVIL SHEETS FOR LOCATION.
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
280154
P-001
VOLUME 3
PL
U
M
BI
N G
L
EG
E N D
, A
BB
R
EV
IA
TI
O N
S, A
N D
N O
TE
S
A
IT
B A
R
RA
CK
S
CO
M
PL
EX
PH
A
SE
3 0
M
A N
N O
R
FO
LK
D
I S
TR
IC
T
N O
R
FO
LK
, V
A
SA
G
EA
M
D
AG
M
LM
A
PR
PR
O
JE
C T
N U
M
BE
R
C O
N
TR
AC
T
N O
P- 0 0
1-
F O R
T L E
E, V
I R G
IN
I A
STORAGE TANK
MARK LOCATION
DIAMETER
(IN)
VOLUME
(GAL)
ST-1 MECHANICAL ROOM 90" 2850
ST-2 MECHANICAL ROOM 90" 2850
ST-3 MECHANICAL ROOM 90" 2850
PLUMBING FIXTURE SCHEDULE
MARK FIXTURE MOUNTING CW HW WASTE VENT
P-1 WATER CLOSET FLOOR 1" - 3" 2"
P-2 WATER CLOSET (ADA) FLOOR 1" - 3" 2"
P-3 URINAL WALL 3/4" - 2" 1 1/2"
P-4 LAVATORY COUNTERTOP 1/2" 1/2" 1 1/2" 1 1/4"
P-5 SHOWER FLOOR / FITTING FLOOR / WALL 1/2" 1/2" 2" 1 1/2"
P-6 WATER COOLER WALL 1/2" - 1 1/2" 1 1/4"
P-7 MOP SINK WALL 3/4" 3/4" 3" 1 1/2"
P-8 WASHMACHINE BOX WALL 1/2" 1/2" 2" 1 1/2"
P-9 UTILITY SINK WALL 3/4" 3/4" 3" 1 1/2"
P-10 KITCHEN SINK COUNTERTOP 1/2" 1/2" 2" 1 1/2"
P-11 ICE MACHINE WALL 1/2" - - -
WATER HEATER SCHEDULE
MARK LOCATION
MBH
INPUT
THERMAL
EFFICIENCY
RECOVERY RATE GPH
(40F TO 100F) ELECTRICAL
WH-1 MECHANICAL ROOM 1300 96% 1513 120/60/1
DRAIN SCHEDULE
MARK SERVICE
OVERALL
DIAMETER (IN) SHAPE WASTE
DD FLOOR & SHOWER
FD-1 FLOOR & SHOWER 6" ROUND 2"
FD-2 FLOOR & SHOWER 6" ROUND 4"
OD-1 OVERFLOW ROOF DRAIN 8" ROUND 4"
RD-1 ROOF DRAIN 8" ROUND 4"
TD-1 TRENCH DRAIN - RECTANGULAR 3"
MIXING VALVE
MARK MIN FLOW (GPM) MAX FLOW (GPM) PRESSURE DROP (PSI) TEMP SETTING (F)
MV-1 13 225 10 120
PUMP SCHEDULE
MARK SERVICE TYPE GPM PUMP TDH POWER (HP) ELECTRICAL NOTES
CP-1 HW RECIRC INLINE 13 10 1/6 115/1/60
CP-2 ELEVATOR SUMP SUMP 30 20 1/2 115/1/60 1
CP-3 WWHP INLINE 30 15 1/4 115/1/60
INTERCEPTOR SCHEDULE
MARK TYPE
CAPACITY
(GAL)
INLET/OUTLET
SIZE (IN) NOTES
SI-1 SAND & SEDIMENT INTERCEPTOR 300 2
LI-1 LINT INTERCEPTOR 2000 4 1
EXPANSION TANK SCHEDULE
MARK LOCATION TYPE ACCEPTANCE VOLUME (GAL)
ET-1 MECHANICAL ROOM BLADDER 211
NOTES:
1. PUMP REQUIRES TWO RECEPTACLES; ONE FOR THE CONTROL PANEL AND ONE FOR THE REMOTE ALARM.
NOTES:
1. FLOOR FOR P-5 SHALL BE 36" x 36".
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
P
ER
A
M
EN
D M
EN
T
M
AY
| Sheets |
| P-001 - PLUMBING LEGEND, ABBREVIATIONS, AND NOTES |