VOL 3_LEE_BCOF_300_16May2016.pdf

PDF 41 MB Posted

Attached to
AIT Barracks- Phase III, Ft. Lee, Virginia Federal contract opportunity
Solicitation number
W91236-16-R-0010
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

Volume 3 Lee BCOF 300 16May2016

View the file

Other files for this federal contract opportunity

Other files attached to AIT Barracks- Phase III, Ft. Lee, Virginia, newest first.
File Type Posted
W91236-16-R-0010-0006.pdf PDF
VOL_2_A-601_3JUN2016.pdf PDF
VOL_2_EL701_3JUN2016.pdf PDF
VOL_3_M-602_3JUN2016.pdf PDF
VOL_2_EP702_3JUN2016.pdf PDF
VOL_3_EP702_3JUN2016.pdf PDF
VOL_3_M-601_3JUN2016.pdf PDF
VOL_4_M-601_3JUN2016.pdf PDF
VOL_4_P-502_3JUN2016.pdf PDF
VOL_3_EP703_3JUN2016.pdf PDF
VOL_2_EP104_3JUN2016.pdf PDF
VOL_2_EP601_3JUN2016.pdf PDF
VOL_2_EP703_3JUN2016.pdf PDF
VOL_3_EP701_3JUN2016.pdf PDF
VOL_2_M-001_3JUN2016.pdf PDF
VOL_3_EL502_3JUN2016.pdf PDF
VOL_3_EP601_3JUN2016.pdf PDF
Am_4_-_Attach_10_VOL_3_A-101_26MAY2016.pdf PDF
Am_4_-_Attach_08_VOL_2_S-003_26MAY2016.pdf PDF
Am_4_-_Attach_23_VOL_4_A-101_26MAY2016.pdf PDF
Am_4_-_Attach_07_VOL_2_G-002_26MAY2016.pdf PDF
Am_4_-_Attach_03_VOL_2_A-101_26MAY2016.pdf PDF
Amendment_4_Breakout.pdf PDF
Am_4_-_Attach_15_VOL_3_G-002_26MAY2016.pdf PDF
Am_4_-_Attach_04_VOL_2_A-112_26MAY2016.pdf PDF
Am_4_-_Attach_20_VOL_3_S-105B_26MAY2016.pdf PDF
Am_4_-_Attach_17_VOL_3_S-102_26MAY2016.pdf PDF
Am_4_-_Attach_12_VOL_3_A-318_26MAY2016.pdf PDF
W91236-16-R-0010-0004.pdf PDF
25May2016_Site_Visit_Roster.pdf PDF
Am_4_-_Attach_01_VOL_1__CS101-103_26MAY2016.pdf PDF
Am_4_-_Attach_02_VOL_2_A-002_26MAY2016.pdf PDF
Am_4_-_Attach_22_VOL_3_S-501_26MAY2016.pdf PDF
synthetic_turf_spec.pdf PDF
VOL_3_EP601_20May2016.pdf PDF
DAYS_BASE_ACCESS_Template_.xlsx XLSX spreadsheet
Amendment_Details_3_20May2016.pdf PDF
VOL_3_P-001_20May2016.pdf PDF
W91236-16-R-0010-0003.pdf PDF
DFAC_SPECS_VOL2_16May2016.pdf PDF
BARRACKS_SPECS_VOL2_16May2016.pdf PDF
DFAC_SPECS_VOL1_16May2016.zip ZIP file
W91236-16-R-0010-00001.pdf PDF
VOL 2_LEE_BCOF_600_16May2016.pdf PDF
VOL 4_LEE_DFAC_16May2016.pdf PDF
H.01.04_LEE_VOLUME_4_DFAC_(ProgressSubmission).zip ZIP file
H.01.04_DFAC_Specifications_21April2016.zip ZIP file
H.01.04__Drainage_Report_21April2016.zip ZIP file
H.01.04_Volume2600PersonBarracks_21April2016.zip ZIP file
H.01.04_Volume4DFACPlans_21April2016.zip ZIP file
Show all 50

AIT Barracks- Phase III, Ft. Lee, Virginia has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

G-001

VOLUME 3

C O

V E R

S H

EE

T

A

IT

B A

R

RA

CK

S

CO

M

PL

EX

PH

A

SE

3 0

M

A N

N O

R

FO

LK

D

I S

TR

IC

T

N O

R

FO

LK

, V

A

D G

G

M C

J

D G

G

D G

G

A

PR

-PR

O

JE

C

T N

U M

BE

R

C O

N

TR

AC

T

N O

G G

-0

F O R

T L E

E, V

I R G

IN

I A

PROJECT NO. 041449

NORFOLK DISTRICT

"BUILDING STRONG"

SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENDATION

AND APPROVAL OF ALL DRAWINGS IN THIS SET AS INDICATED ON

INDEX OF DRAWINGS.

CHIEF, ENGINEERING & CONSTRUCTION DIVISION

APPROVED

CHIEF, ENGINEERING BRANCH

APPROVED

ENGINEERING BRANCH DESIGN LEAD

RECOMMENDED

FY 15

CONTRACT NO.

AIT BARRACKS COMPLEX, PHASE 3

VOLUME 3

300 MAN BARRACKS

FORT LEE, VIRGINIA

VOLUME 1 SITE

VOLUME 2 600 MAN BARRACKS

VOLUME 3 300 MAN BARRACKS

VOLUME 4 DINING FACILITY

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

SHEET OF

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

G-002

VOLUME 3

IN

D

EX

O

F D

R A W

IN

G

S

A

IT

B A

R

RA

CK

S

CO

M

PL

EX

PH

A

SE

3 0

M

A N

N O

R

FO

LK

D

I S

TR

IC

T

N O

R

FO

LK

, V

A

D G

G

M C

J

D G

G

D G

G

A

PR

-PR

O

JE

C

T N

U M

BE

R

C O

N

TR

AC

T

N O

G G

-0

F O R

T L E

E, V

I R G

IN

I A

INDEX OF DRAWINGS

SHEET ID

SHEET

NUMBER SHEET NAME

A-206 64 WEST ELEVATION

A-207 65 EAST ELEVATION

A-301 66 BUILDING SECTION (NORTH-SOUTH CORE)

A-302 67 BUILDING SECTION (NORTH-SOUTH WING)

A-303 68 BUILDING SECTION (EAST-WEST)

A-311 69 TYPICAL WALL SECTION

A-312 70 WALL SECTIONS

A-313 71 WALL SECTIONS

A-314 72 WALL SECTIONS

A-315 73 WALL SECTIONS

A-316 74 WALL SECTIONS

A-317 75 WALL SECTIONS

A-318 76 WALL SECTIONS

A-331 77 SECTION DETAILS

A-332 78 SECTION DETAILS

A-401 79 ENLARGED PLANS - 3PN

A-402 80 ENLARGED PLANS - 2PN

A-403 81 ENLARGED PLANS - 2PN IN AREA "B"

A-404 82 ENLARGED PLANS - TOILET ROOMS

A-405 83 INTERIOR ELEVATIONS - TOILETS/MISC.

A-406 84 ENLARGED DRAWINGS - LAUNDRY + SCRUB ROOM

A-407 85 ENLARGED TOILET ROOM DETAILS

A-408 86 COUNTER DETAILS

A-411 87 ENLARGED DRAWINGS - CQ DESK

A-412 88 ENLARGED DRAWINGS - DISPLAY CASE

A-421 89 ENLARGED STAIR PLANS

A-422 90 ENLARGED STAIR SECTIONS

A-423 91 STAIR DETAILS

A-431 92 ELEVATOR DRAWINGS

A-501 93 MISC. DETAILS

A-502 94 MISC. DETAILS

A-503 95 MISC. DETAILS

A-504 96 PRE-CAST SCHEDULE

A-511 97 SUSPENDED CEILING DETAIL

A-521 98 ROOF DETAILS

A-522 99 ROOF DETAILS

A-523 100 ROOF ACCESS DRAWINGS

A-531 101 EXPANSION JOINT DETAILS

A-541 102 COVERED TRAINING AREA PLANS + ELEVATIONS

A-542 103 COVERED TRAINING AREA DETAILS

A-551 104 LAWN EQUIPMENT BUILDING DRAWINGS

A-601 105 DOOR SCHEDULE

A-602 106 DOOR DETAILS

A-611 107 WINDOW DETAILS

A-612 108 LOUVER TYPES + PRECAST CONCRETE COPING DETAILS

A-901 109 NORTHEAST PERSPECTIVE

A-902 110 SOUTHWEST PERSPECTIVE

INTERIORS

F-100 111 OVERALL FIRST FLOOR FURNITURE PLAN

F-101 112 OVERALL SECOND FLOOR FURNITURE PLAN

F-102 113 FIRST FLOOR AREA "A" & "C" (2 - 5 FLOOR SIM.) FURNITURE PLAN

F-103 114 FIRST FLOOR AREA "B" FURNITURE PLAN

F-104 115 SECOND FLOOR AREA "B" FURNITURE PLAN

F-105 116 THIRD AND FOURTH FLOOR AREA "B" FURNITURE PLAN

F-106 117 FIFTH FLOOR AREA "B" FURNITURE PLAN

F-107 118 ENLARGED FURNITURE PLANS

I-100 119 FINISH MATERIAL LEGEND AND NOTES

I-101 120 INTERIOR FINISH SCHEDULE

I-200 121 FLOOR PATTERN PLAN - AREA 'A' & 'C'

I-201 122 FLOOR PATTERN PLAN - AREA 'B'

I-202 123 SECOND FLOOR PATTERN PLAN - AREA 'B'

I-300 124 SIGNAGE SCHEDULE AND DETAILS

I-301 125 SIGNAGE DETAILS

I-302 126 FIRST FLOOR (FLOOR 2 - 5 SIM.) SIGNAGE PLACEMENT PLAN - AREA 'A' & 'C'

I-303 127 FIRST FLOOR SIGNAGE PLACEMENT PLAN - AREA 'B'

I-304 128 SECOND & THIRD FLOOR SIGNAGE PLACEMENT PLAN - AREA 'B'

I-305 129 FOURTH & FIFTH FLOOR SIGNAGE PLACEMENT PLAN - AREA 'B'

INDEX OF DRAWINGS

SHEET ID

SHEET

NUMBER SHEET NAME

GENERAL

G-001 1 COVER SHEET

G-002 2 INDEX OF DRAWINGS

G-003 3 INDEX OF DRAWINGS

LIFE SAFETY

LS001 4 BUILDING AND LIFE SAFETY CODE ANALYSIS

LS101 5 300 MAN - FIRST FLOOR PLAN - LIFE SAFETY

LS102 6 300 MAN - SECOND FLOOR PLAN - LIFE SAFETY

LS103 7 300 MAN - THIRD FLOOR PLAN - LIFE SAFETY

LS104 8 300 MAN - FOURTH FLOOR PLAN - LIFE SAFETY

LS105 9 300 MAN - FIFTH FLOOR PLAN - LIFE SAFETY

STRUCTURAL

S-001 10 GENERAL STRUCTURAL NOTES, DESIGN LOADS & ABBREVIATIONS

S-002 11 WALL FRAMING SCHEDULES AND WALL OPENING DETAILS

S-003 12 SCHEDULES

S-101 13 FOUNDATION AND FIRST FLOOR FRAMING PLAN - AREA A

S-102 14 FOUNDATION AND FIRST FLOOR FRAMING PLAN - AREA B

S-103 15 FOUNDATION AND FIRST FLOOR FRAMING PLAN - AREA C

S-104 16 SECOND - FIFTH FLOOR FRAMING PLAN - AREA A

S-105 17 SECOND FLOOR FRAMING PLAN - AREA B

S-105A 18 THIRD FLOOR FRAMING PLAN - AREA B

S-105B 19 FOURTH FLOOR FRAMING PLAN - AREA B

S-106 20 SECOND - FIFTH FLOOR FRAMING PLAN - AREA C

S-107 21 FIFTH FLOOR FRAMING PLAN - AREA B

S-108 22 TIE FORCE PLAN

S-109 23 ROOF FRAMING PLAN - AREA A

S-110 24 ROOF FRAMING PLAN - AREA B

S-111 25 ROOF FRAMING PLAN - AREA C

S-112 26 COVERED ASSEMBLY PLAN AND DETAILS

S-113 27 COVERED ASSEMBLY PLAN AND DETAILS

S-301 28 FOUNDATION SECTIONS

S-302 29 FOUNDATION SECTIONS

S-303 30 FOUNDATION TYPICAL DETAILS

S-304 31 FRAMING DETAILS

S-305 32 FRAMING DETAILS

S-501 33 X-BRACE FRAME ELEVATIONS

S-502 34 X-BRACE FRAME SECTIONS AND DETAILS

S-503 35 TYPICAL CFMF DETAILS

S-601 36 TRUSS ELEVATIONS

ARCHITECTURAL

A-001 37 ARCHITECTURAL ABBREVIATIONS + SYMBOLS

A-002 38 WALL TYPES + LEGEND

A-011 39 AIR BARRIER PLANS

A-012 40 AIR BARRIER PLANS

A-013 41 AIR BARRIER BUILDING SECTIONS

A-014 42 AIR BARRIER DETAILS

A-101 43 OVERALL FIRST FLOOR PLAN

A-102 44 OVERALL SECOND - THIRD FLOOR PLAN

A-103 45 OVERALL FOURTH - FIFTH FLOOR PLANS

A-104 46 OVERALL ROOF PLAN

A-111 47 FIRST FLOOR PLAN AREA "A" AND "C"

A-112 48 FIRST FLOOR PLAN AREA "B"

A-113 49 SECOND FLOOR PLAN AREA "A" AND "C"

A-114 50 SECOND FLOOR PLAN AREA "B"

A-115 51 THIRD - FOURTH FLOOR PLANS AREA "B"

A-116 52 FIFTH FLOOR PLAN AREA "B"

A-131 53 FIRST FLOOR RCP AREA "A" AND "C"

A-132 54 FIRST FLOOR RCP AREA "B"

A-133 55 SECOND - THIRD FLOOR RCP AREA "B"

A-134 56 FOURTH - FIFTH FLOOR RCP AREA "B"

A-151 57 ROOF PLAN AREA "A" AND "C"

A-152 58 ROOF PLAN AREA "B"

A-201 59 OVERALL EXTERIOR ELEVATION

A-202 60 PARTIAL NORTH ELEVATION (AREA A AND AREA C)

A-203 61 PARTIAL NORTH ELEVATION (AREA B)

A-204 62 PARTIAL SOUTH ELEVATION (AREA A AND AREA C)

A-205 63 PARTIAL SOUTH ELEVATION (AREA B)

M

AR

K D

ES

C

R

IP

TI

O

N D

SHEET OF

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

G-003

VOLUME 3

IN

D

EX

O

F D

R A W

IN

G

S

A

IT

B A

R

RA

CK

S

CO

M

PL

EX

PH

A

SE

3 0

M

A N

N O

R

FO

LK

D

I S

TR

IC

T

N O

R

FO

LK

, V

A

D G

G

M C

J

D G

G

D G

G

A

PR

-PR

O

JE

C

T N

U M

BE

R

C O

N

TR

AC

T

N O

G G

-0

F O R

T L E

E, V

I R G

IN

I A

INDEX OF DRAWINGS

SHEET ID

SHEET

NUMBER SHEET NAME

M-601 205 SCHEDULES

M-602 206 SCHEDULES

M-701 207 DIAGRAMS

MI801 208 CONTROLS

MI802 209 CONTROLS

MI803 210 CONTROLS

MI804 211 CONTROLS

ELECTRICAL

E-001 212 ELECTRICAL LEGEND, ABBREVIATIONS, AND NOTES

E-002 213 GENERAL NOTES

EL101 214 300 MAN - FIRST FLOOR PLAN - AREA 'A' & 'C' - LIGHTING

EL102 215 300 MAN - FIRST FLOOR PLAN - AREA 'B' - LIGHTING

EL103 216 300 MAN - SECOND FLOOR PLAN - AREA 'A' & 'C' - LIGHTING

EL104 217 300 MAN - SECOND FLOOR PLAN - AREA 'B' - LIGHTING

EL105 218 300 MAN - THIRD FLOOR PLAN - AREA 'A' & 'C' - LIGHTING

EL106 219 300 MAN - THIRD FLOOR PLAN - AREA 'B' - LIGHTING

EL107 220 300 MAN - FOURTH FLOOR PLAN - AREA 'A' & 'C' - LIGHTING

EL108 221 300 MAN - FOURTH FLOOR PLAN - AREA 'B' - LIGHTING

EL109 222 300 MAN - FIFTH FLOOR PLAN - AREA 'A' & 'C' - LIGHTING

EL110 223 300 MAN - FIFTH FLOOR PLAN - AREA 'B' - LIGHTING

EL301 224 300 MAN - STAIRWELL LIGHTING SECTIONS

EL501 225 LIGHTING FIXTURE SCHEDULE

EL502 226 LIGHTING FIXTURE DETAILS

EL503 227 LIGHTING FIXTURE DETAILS

EL601 228 ELECTRICAL - LIGHTING - SEQUENCE OF OPERATION

EL602 229 ELECTRICAL - LIGHTING - SEQUENCE OF OPERATION

EL701 230 ELECTRICAL - LIGHTING - CONTROLS RISER

EL702 231 ELECTRICAL - LIGHTING - ELEVATOR PIT

EP101 232 300 MAN - FIRST FLOOR PLAN - AREA 'A' & 'C' - POWER

EP102 233 300 MAN - FIRST FLOOR PLAN - AREA 'B' - POWER

EP103 234 300 MAN - SECOND FLOOR PLAN - AREA 'A' & 'C' - POWER

EP104 235 300 MAN - SECOND FLOOR PLAN - AREA 'B' - POWER

EP105 236 300 MAN - THIRD FLOOR PLAN - AREA 'A' & 'C' - POWER

EP106 237 300 MAN - THIRD FLOOR PLAN - AREA 'B' - POWER

EP107 238 300 MAN - FOURTH FLOOR PLAN - AREA 'A' & 'C' - POWER

EP108 239 300 MAN - FOURTH FLOOR PLAN - AREA 'B' - POWER

EP109 240 300 MAN - FIFTH FLOOR PLAN - AREA 'A' & 'C' - POWER

EP110 241 300 MAN - FIFTH FLOOR PLAN - AREA 'B' - POWER

EP111 242 300 MAN - ROOF PLAN - LIGHTNING PROTECTION

EP112 243 COVERED ASSEMBLY AND LAWN EQUIPMENT BUILDING PLANS

EP113 244 ELECTRICAL - LIGHTNING PROTECTION - DETAILS

EP601 245 ELECTRICAL - POWER - RISER DIAGRAM

EP602 246 ELECTRICAL - POWER - SWITCHBOARD ELEVATION AND DUCTBANK DETAIL

EP701 247 ELECTRICAL - POWER - MECHANICAL EQUIPMENT SCHEDULES

EP702 248 ELECTRICAL - POWER - PANEL SCHEDULES

EP703 249 ELECTRICAL - POWER - PANEL SCHEDULES

EP704 250 ELECTRICAL - POWER - PANEL SCHEDULES

EP705 251 ELECTRICAL - POWER - PANEL SCHEDULES

EP706 252 ELECTRICAL - POWER - PANEL SCHEDULES

EP707 253 ELECTRICAL - POWER - PANEL SCHEDULES

EP708 254 ELECTRICAL - POWER - PANEL SCHEDULES

EP709 255 ELECTRICAL - POWER - PANEL SCHEDULES

EP710 256 ELECTRICAL - POWER - PANEL SCHEDULES

EP711 257 ELECTRICAL - POWER - PANEL SCHEDULES

EP712 258 ELECTRICAL - POWER - PANEL SCHEDULES

EP713 259 ELECTRICAL - POWER - PANEL SCHEDULES

EP714 260 ELECTRICAL - POWER - PANEL SCHEDULES

EP715 261 ELECTRICAL - POWER - PANEL SCHEDULES

EP716 262 ELECTRICAL - POWER - PANEL SCHEDULES

TELECOMMUNICATIONS

T-001 263 TELECOMMUNICATIONS & SECURITY LEGEND, ABBREVIATIONS, AND NOTES

T-101 264 300 MAN - FIRST FLOOR PLAN - AREA 'A' & 'C' - TELECOMMUNICATIONS & SECURITY

T-102 265 300 MAN - FIRST FLOOR PLAN - AREA 'B' - TELECOMMUNICATIONS & SECURITY

T-103 266 300 MAN - SECOND FLOOR PLAN - AREA 'A' & 'C' - TELECOMMUNICATIONS & SECURITY

T-104 267 300 MAN - SECOND FLOOR PLAN - AREA 'B' - TELECOMMUNICATIONS & SECURITY

T-105 268 300 MAN - THIRD FLOOR PLAN - AREA 'A' & 'C' - TELECOMMUNICATIONS & SECURITY

T-106 269 300 MAN - THIRD FLOOR PLAN - AREA 'B' - TELECOMMUNICATIONS & SECURITY

T-107 270 300 MAN - FOURTH FLOOR PLAN - AREA 'A' & 'C' - TELECOMMUNICATIONS & SECURITY

T-108 271 300 MAN - FOURTH FLOOR PLAN - AREA 'B' - TELECOMMUNICATIONS & SECURITY

T-109 272 300 MAN - FIFTH FLOOR PLAN - AREA 'A' & 'C' - TELECOMMUNICATIONS & SECURITY

T-110 273 300 MAN - FIFTH FLOOR PLAN - AREA 'B' - TELECOMMUNICATIONS & SECURITY

T-401 274 TELECOMMUNICATION ROOM PLANS AND ELEVATIONS

T-501 275 TELECOMMUNICATIONS DETAILS

T-502 276 TELECOMMUNICATIONS DETAILS

T-601 277 TELECOMMUNICATIONS RISER DIAGRAM

T-602 278 TELECOMMUNICATIONS RISER DIAGRAM

T-603 279 TELECOMMUNICATIONS ARMS VAULT SECURITY DETAILS

TS101 280 TELECOMMUNICATIONS SITE PLAN

INDEX OF DRAWINGS

SHEET ID

SHEET

NUMBER SHEET NAME

FIRE PROTECTION / FIRE ALARM

FP001 130 FIRE PROTECTION LEGEND, ABBREVIATIONS, AND SCHEDULES

FP101 131 300 MAN - FIRST FLOOR PLAN - AREA 'A' & 'C' - SPRINKLER

FP102 132 300 MAN - FIRST FLOOR PLAN - AREA 'B' - SPRINKLER

FP103 133 300 MAN - SECOND FLOOR PLAN - AREA 'A' & 'C' - SPRINKLER

FP104 134 300 MAN - SECOND FLOOR PLAN - AREA 'B' - SPRINKLER

FP105 135 300 MAN - THIRD FLOOR PLAN - AREA 'A' & 'C' - SPRINKLER

FP106 136 300 MAN - THIRD FLOOR PLAN - AREA 'B' - SPRINKLER

FP107 137 300 MAN - FOURTH FLOOR PLAN - AREA 'A' & 'C' - SPRINKLER

FP108 138 300 MAN - FOURTH FLOOR PLAN - AREA 'B' - SPRINKLER

FP109 139 300 MAN - FIFTH FLOOR PLAN - AREA 'A' & 'C' - SPRINKLER

FP110 140 300 MAN - FIFTH FLOOR PLAN - AREA 'B' - SPRINKLER

FA001 141 FIRE ALARM & MASS NOTIFICATION SYSTEM LEGEND, ABBREVIATIONS, AND NOTES

FA101 142 300 MAN - FIRST FLOOR PLAN - AREA 'A' & 'C' - FIRE ALARM & MASS NOTIFICATION SYSTEM FA102 143 300 MAN - FIRST FLOOR PLAN - AREA 'B' - FIRE ALARM & MASS NOTIFICATION SYSTEM FA103 144 300 MAN - SECOND FLOOR PLAN - AREA 'A' & 'C' - FIRE ALARM & MASS NOTIFICATION SYSTEM FA104 145 300 MAN - SECOND FLOOR PLAN - AREA 'B' - FIRE ALARM & MASS NOTIFICATION SYSTEM FA105 146 300 MAN - THIRD FLOOR PAN - AREA 'A' & 'C' - FIRE ALARM & MASS NOTIFICATION SYSTEM FA106 147 300 MAN - THIRD FLOOR PLAN - AREA 'B' - FIRE ALARM & MASS NOTIFICATION SYSTEM FA107 148 300 MAN - FOURTH FLOOR PLAN - AREA 'A' & 'C' - FIRE ALARM & MASS NOTIFICATION SYSTEM FA108 149 300 MAN - FOURTH FLOOR PLAN - AREA 'B' - FIRE ALARM & MASS NOTIFICATION SYSTEM FA109 150 300 MAN - FIFTH FLOOR PLAN - AREA 'A' & 'C' - FIRE ALARM & MASS NOTIFICATION SYSTEM FA110 151 300 MAN - FIFTH FLOOR PLAN - AREA 'B' - FIRE ALARM & MASS NOTIFICATION SYSTEM

FA601 152 FIRE ALARM AND MASS NOTIFICATION RISER DIAGRAM

FA602 153 SEQUENCE OF OPERATION

PLUMBING

P-001 154 PLUMBING LEGEND, ABBREVIATIONS, AND NOTES

PF101 155 300 MAN - FIRST FLOOR PLAN - AREA 'A' & 'C' - SANITARY

PF102 156 300 MAN - FIRST FLOOR PLAN - AREA 'B' - SANITARY

PF103 157 300 MAN - SECOND FLOOR PLAN - AREA 'A' & 'C' - SANITARY

PF104 158 300 MAN - SECOND FLOOR PLAN - AREA 'B' - SANITARY

PF105 159 300 MAN - THIRD FLOOR PLAN - AREA 'A' & 'C' - SANITARY

PF106 160 300 MAN - THIRD FLOOR PLAN - AREA 'B' - SANITARY

PF107 161 300 MAN - FOURTH FLOOR PLAN - AREA 'A' & 'C' - SANITARY

PF108 162 300 MAN - FOURTH FLOOR PLAN - AREA 'B' - SANITARY

PF109 163 300 MAN - FIFTH FLOOR PLAN - AREA 'A' & 'C' - SANITARY

PF110 164 300 MAN - FIFTH FLOOR PLAN - AREA 'B' - SANITARY

PL101 165 300 MAN - FIRST FLOOR PLAN - AREA 'A' & 'C' - PLUMBING

PL102 166 300 MAN - FIRST FLOOR PLAN - AREA 'B' - PLUMBING

PL103 167 300 MAN - SECOND FLOOR PLAN - AREA 'A' & 'C' - PLUMBING

PL104 168 300 MAN - SECOND FLOOR PLAN - AREA 'B' - PLUMBING

PL105 169 300 MAN - THIRD FLOOR PLAN - AREA 'A' & 'C' - PLUMBING

PL106 170 300 MAN - THIRD FLOOR PLAN - AREA 'B' - PLUMBING

PL107 171 300 MAN - FOURTH FLOOR PLAN - AREA 'A' & 'C' - PLUMBING

PL108 172 300 MAN - FOURTH FLOOR PLAN - AREA 'B' - PLUMBING

PL109 173 300 MAN - FIFTH FLOOR PLAN - AREA 'A' & 'C' - PLUMBING

PL110 174 300 MAN - FIFTH FLOOR PLAN - AREA 'B' - PLUMBING

P-501 175 DETAILS

P-502 176 DETAILS

P-601 177 ISOMETRICS

P-602 178 ISOMETRICS

MECHANICAL

M-001 179 MECHANICAL LEGEND, ABBREVIATIONS, AND NOTES

MH101 180 300 MAN - FIRST FLOOR PLAN - AREA 'A' & 'C' - HVAC

MH102 181 300 MAN - FIRST FLOOR PLAN - AREA 'B' - HVAC

MH103 182 300 MAN - SECOND FLOOR PLAN - AREA 'A' & 'C' - HVAC

MH104 183 300 MAN - SECOND FLOOR PLAN - AREA 'B' - HVAC

MH105 184 300 MAN - THIRD FLOOR PLAN - AREA 'A' & 'C' - HVAC

MH106 185 300 MAN - THIRD FLOOR PLAN - AREA 'B' - HVAC

MH107 186 300 MAN - FOURTH FLOOR PLAN - AREA 'A' & 'C' - HVAC

MH108 187 300 MAN - FOURTH FLOOR PLAN - AREA 'B' - HVAC

MH109 188 300 MAN - FIFTH FLOOR PLAN - AREA 'A' & 'C' - HVAC

MH110 189 300 MAN - FIFTH FLOOR PLAN - AREA 'B' - HVAC

MP101 190 300 MAN - FIRST FLOOR PLAN - AREA 'A' & 'C' - HVAC PIPING

MP102 191 300 MAN - FIRST FLOOR PLAN - AREA 'B' - HVAC PIPING

MP103 192 300 MAN - SECOND FLOOR PLAN - AREA 'A' & 'C' - HVAC PIPING

MP104 193 300 MAN - SECOND FLOOR PLAN - AREA 'B' - HVAC PIPING

MP105 194 300 MAN - THIRD FLOOR PLAN - AREA 'A' & 'C' - HVAC PIPING

MP106 195 300 MAN - THIRD FLOOR PLAN - AREA 'B' - HVAC PIPING

MP107 196 300 MAN - FOURTH FLOOR PLAN - AREA 'A' & 'C' - HVAC PIPING

MP108 197 300 MAN - FOURTH FLOOR PLAN - AREA 'B' - HVAC PIPING

MP109 198 300 MAN - FIFTH FLOOR PLAN - AREA 'A' & 'C' - HVAC PIPING

MP110 199 300 MAN - FIFTH FLOOR PLAN - AREA 'B' - HVAC PIPING

M-301 200 SECTIONS AND ELEVATIONS

M-401 201 ENLARGED PLANS

M-402 202 ENLARGED PLANS

M-501 203 DETAILS

M-502 204 DETAILS

M

AR

K D

ES

C

R

IP

TI

O

N D

BUILDING AND LIFE SAFETY CODE ANALYSIS

TOPIC DESIGN REFERENCE DESCRIPTION

1. GOVERNING CODES AND CRITERIA UFC 3-600-01 UNIFIED FACILITIES CRITERIA, FIRE PROTECTION ENGINEERING

FOR FACILITIES, CHANGE 3, 1 MAR 2013

IBC INTERNATIONAL BUILDING CODE, 2012 EDITION

NFPA 101 NATIONAL FIRE PROTECTION ASSOCIATION, LIFE SAFETY

CODE, 2012 EDITION

NFPA 90A STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND

VENTILATING SYSTEMS, 2012 EDITION

2. OCCUPANCY CLASSIFICATION GROUP R-2 , RESIDENTIAL IBC, 310.1 OCCUPANCIES INCLUDING DORMITORIES

GROUP A-3, ASSEMBLY IBC, 303 FIRST FLOOR ONLY, OCCUPANCIES NOT CLASSIFIED ELSEWHERE IN GROUP A

3. CONSTRUCTION TYPE TYPE II-B IBC, 602.2, TABLE 601

FIRST FLOOR IS MIXED, NONSEPARATED OCCUPANCY R-2, A-3, B, AND S-1

4. AREA LIMITATIONS FIRST FLOOR IBC TABLE 503, 506

NONCOMBUSTIBLE, UNPROTECTED CONSTRUCTION

SUM OF RATIOS = 1.54 IBC 506.5.2

ALLOWABLE: 16,000 SF X 3.75 (SPRINKLER AND FRONTAGE) = 60,000 SF

5. HEIGHT LIMITATIONS 60 FEET IBC TABLE 503, 504.2 ALLOWABLE: 55 FEET + 20 FEET (SPRINKLERS) = 75 FEET

6. NUMBER OF STORIES IBC TABLE 503, 504.2 ALLOWABLE: 4 STORIES + 1 STORY (SPRINKLERS) = 5 STORIES

7. OCCUPANCY SEPARATIONS IBC 709.3, EXCEPTION 2 TYPE II-B CONSTRUCTION AND SPRINKLERS EXCEPTION ALLOWS 1/2 PARTITIONS

8. STRUCTURAL FIRE RESISTANCE SEE DESCRIPTION IBC TABLE 601 PRIMARY STRUCTURAL FRAME: 0 HOURS

BEARING WALLS, INTERIOR: 0 HOURS

BEARING WALLS, EXTERIOR: 0 HOURS

NONBEARING WALLS AND PARTITIONS, EXTERIOR: 0 HOURS

NONBEARING WALLS AND PARTITIONS, INTERIOR: SEE ITEM 12 BELOW

FLOOR CONSTRUCTION AND SECONDARY MEMBERS: 0 HOURS

ROOF CONSTRUCTION AND SECONDARY MEMBERS: 0 HOURS

9. AUTOMATIC SPRINKLERS PROVIDED UFC 3-600-01, 4-2.2 REQUIRED IN ALL NEW DOD FACILITIES

10. PORTABLE FIRE EXTINGUISHERS PROVIDED, TYPE AND SPACING PER NFPA 10 NFPA 101, 28.3.5.8 NOT REQUIRED

EXIT ENCLOSURES, 2 HOUR FIRE BARRIER NFPA 101, 7.1.3.2 (1) 2 HOUR REQUIRED FOR GREATER THAN 3 STORIES11. ENCLOSURE PROTECTION CORRIDORS, 1/2 HOUR FIRE BARRIER NFPA 101, 28.3.6.1.3 1/2 HOUR REQUIRED WHEN SPRINKLER PROVIDED; SPACES OTHER THAN DWELLING UNITS

ARE PERMITTED TO BE OPEN TO THE CORRIDOR PER NFPA 101, 28.3.6.3.2

DWELLING UNITS, 1/2 HOUR FIRE BARRIERS NFPA 101, 28.3.7.2 1/2 HOUR REQUIRED WHEN SPRINKLER PROVIDED

12. FIRE AND SMOKE DAMPERS NFPA 90A

13. DOOR REQUIREMENTS DOORS IN 1/2 HOUR RATED WALLS NFPA 101, TABLE 8.3.4.2 20 MINUTES FIRE RATING, WITH DOOR CLOSERS

14. FIRE DETECTION, ALARM, AND EVACUATION SYSTEM MANUAL AND AUTOMATIC SYSTEMS PROVIDED NFPA 101, 28.3.4.3

15. INTERIOR FINISHES WALLS, EXIT ENCLOSURES, CLASS A NFPA 101, 28.3.3.2 CLASS A REQUIRED

WALLS, LOBBIES AND CORRIDORS, CLASS A OR B NFPA 101, 28.3.3.2 CLASS A OR B REQUIRED WALLS, OTHER SPACES, CLASS A, B, OR C NFPA 101, 28.3.3.2 CLASS A, B, OR C REQUIRED

16. MEANS OF EGRESS, OCCUPANT LOAD BUSINESS NFPA 101, TABLE 7.1.3.2 FIRST FLOOR ONLY, 100 SF / OCCUPANT 1,020 SF = 11 PERSONS

17. NUMBER OF MEANS OF EGRESS 1ST FLOOR, 5 PROVIDED NFPA 101, 7.4.1.2 2 REQUIRED

2ND THRU 5TH FLOORS, 3 PROVIDED 2 REQUIRED

18. EGRESS DISTANCE LIMITATIONS NFPA 101, TABLE A.7.6 MAX COMMON PATH REQUIRED = 100 FEET

IBC 712, EXCEPTION TYPE II-B CONSTRUCTION AND SPRINKLERS EXCEPTION

5 STORIES

DWELLING UNIT WALLS 1/2 FIRE BARRIERS

GROUP B, BUSINESS IBC, 304

GROUP S-1, STORAGE IBC, 311.2

FIRST FLOOR ONLY, OCCUPANCIES USED FOR OFFICES, EDUCATION ABOVE 12TH GRADE

FIRST FLOOR ONLY, MODERATE HAZARD STORAGE

R-2, 30,983 SF

A-3, 2,405 SF

B, 1,020 SF

S-1, 804 SF

2ND THRU 5TH FLOORS

R-2, 27,876 SF IBC TABLE 503, 506

ALLOWABLE: 16,000 SF X 3.75 (SPRINKLER AND FRONTAGE) = 60,000 SF

ALLOWABLE: 9,500 SF X 3.75 = 35,635 SF

ALLOWABLE: 23,000 SF X 3.75 = 86,250 SF

ALLOWABLE: 17,500 SF X 3.75 = 65,625 SF

30,983 / 60,000 + 2,405 / 35,635 + 1,020 / 86,250 + 804 / 65,625 + 2 X 27,876/60,000 = 1.54 < 3

DWELLING UNIT HORIZONTAL SEPARATIONS 1/2 HOUR

LAUNDRY ROOMS, 1 HOUR FIRE BARRIERS NFPA 101, TABLE 28.3.2.2.2 1 HOUR AND SPRINKLERS BOILER ROOMS, 1 HOUR FIRE BARRIERS NFPA 101, TABLE 28.3.2.2.2 1 HOUR AND SPRINKLERS STORAGE ROOMS, 1 HOUR FIRE BARRIERS NFPA 101, TABLE 28.3.2.2.2 PROVIDED, EXCEPT FOR SMALL CLOSETS, NOTED BY SUB-NOTE C IN TABLE

SHAFT ENCLOSURES NFPA 90A, 5.3.4.2 2 HOUR REQUIRED FOR GREATER THAN 4 STORIES

DOORS IN 1 HOUR RATED WALLS NFPA 101, TABLE 8.3.4.2 45 MINUTES FIRE RATING, WITH DOOR CLOSERS

DOORS AT 2 HOUR EXIT ENCLOSURES (STAIRS) NFPA 101, TABLE 8.3.4.2 1-1/2 HOUR RATING

MANUAL AND AUTOMATIC SYSTEMS PROVIDED

FLOORS, EXIT ENCLOSURES AND CORRIDORS, CLASS II NFPA 101, 28.3.3.3 CLASS II REQUIRED

ASSEMBLY NFPA 101, TABLE 7.1.3.2 FIRST FLOOR ONLY, 15 SF / OCCUPANT 2,405 SF = 162 PERSONS RESIDENTIAL NFPA 101, TABLE 7.1.3.2 FIRST FLOOR ONLY, 200 SF / OCCUPANT 30,983 SF = 155 PERSONS STORAGE ROOMS, 1 HOUR FIRE BARRIERS NFPA 101, TABLE 7.1.3.2 13 PERSONS, 500 SF / OCCUPANT, MINIMUM 1 OCCUPANT PER ROOM RESIDENTIAL NFPA 101, TABLE 7.1.3.2 2ND THRU 5TH FLOORS, SURGE CONDITIONS, 3 OCCUPANT PER ROOM = 150 PERSONS TOTAL = 640 PERSONS DOES NOT INCLUDE INDIVIDUAL ROOMS WITH DIRECT ACCESS TO THE EXTERIOR WITH

NO ACCESS TO THE OTHER INTERIOR SPACES

NFPA 101, 7.4.1.2

NFPA 101, TABLE A.7.6 MAX DEAD END PATH REQUIRED = 50 FEET

NFPA 101, TABLE A.7.6 MAX TRAVEL DISTANCE PATH REQUIRED = 300 FEET

RESIDENTIAL

MAX COMMON PATH REQUIRED = 20 FEET

MAX DEAD END PATH REQUIRED = 20 FEET

MAX TRAVEL DISTANCE PATH REQUIRED = 250 FEET

MAX COMMON PATH REQUIRED = 50 FEET

MAX DEAD END PATH REQUIRED = 50 FEET

MAX TRAVEL DISTANCE PATH REQUIRED = 325 FEET

NFPA 101, TABLE A.7.6

NFPA 101, TABLE A.7.6

NFPA 101, TABLE A.7.6

NFPA 101, TABLE A.7.6

NFPA 101, TABLE A.7.6

NFPA 101, TABLE A.7.6

ASSEMBLY

BUSINESS

NOT REQUIRED FOR WALLS 1 HOUR OR LESSNONE PROVIDED

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

LS001

VOLUME 3

BU

IL

D

IN

G A

N D

L

IF

E

SA

FE

TY

C O

D E

AN

AL

YS

IS

A

IT

B A

R

RA

CK

S

CO

M

PL

EX

PH

A

SE

3 0

M

A N

N O

R

FO

LK

D

I S

TR

IC

T

N O

R

FO

LK

, V

A

R C

N

EA

M

D

AG

D G

G

A

PR

PR

O

JE

C T

N U

M

BE

R

C O

N

TR

AC

T

N O

LS

0 0

1-

F O R

T L E

E, V

I R G

IN

I A

M

AR

K D

ES

C

R

IP

TI

O

N D

OCCUPANT LOAD

EGRESS ROUTE DISTANCE (IN FEET)

TD = TRAVEL DISTANCE TO EXIT

CP = COMMON PATH OF TRAVEL

DE = DEAD END

25 C

EXIT

(NOT ALL EXITS ARE ACCESSIBLE)

ACCESSIBLE EXIT

TD = 150'

EXIT CAPACITY, CAPACITY OF DOOR

OR OTHER EGRESS COMPONENT

EXC

EXIT LOAD, NUMBER OF OCCUPANTS

UTILIZING EGRESS COMPONENT

EXL

FIRE EXTINGUISHER LOCATION

E

1 HOUR FIRE BARRIER

1/2 HOUR FIRE BARRIER

FIRE AND LIFE SAFETY LEGEND

FE

FEC FIRE EXTINGUISHER CABINET

LOCATION

1/2 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

2 HOUR FIRE BARRIER

1 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

2 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

STAIRS #1

2PN

3PN

3PN

3PN

3PN

2PN

LAUNDRY

STAIRS #2

CORRIDOR

2PN

2PN

3PN

3PN

3PN

3PN

2PN

CORRIDOR

CORRIDOR

DAY ROOM

COMPUTER

LEARNING

WOMEN'S

OPS SGT

1ST SGT

VESTIBULE

XO

CDR

1006G STO

MEN'S

G STO

G STO

JAN #2

RESTROOM

1024A

WAITING

ELEC

LUGGAGE

G STO

G STO

RECYCLE

STORAGE

ELEVATOR

E1

WOMEN'S

MEN'S

1031PROFILE

JAN

COMP STO

AV

1035B

AV

1035A

MULTI-PURPOSE

STO

1035C

STO

1035D

STO

1035E

ELECTRICAL

MECHANICAL

SCRUB

VAULT

SUPPLY

MECHANICAL

PLT SGT OFFICE

DAY ROOM

2PN

3PN

3PN

3PN

3PN

2PN

2PN

STAIRS #3

2PN

3PN

3PN

3PN

3PN

2PN

LAUNDRY

COMM

CORRIDOR

CORRIDOR

E

TD = 135'

EXC = 165

EXL = 45

26 C

E

E

E E

EXC = 345

EXL = 81

EXC = 345

EXL = 81

EXC = 345

EXL = 86

EXC = 165

EXL = 45

22 C

54 C 54 C 54 C

21 C

25 C

TD = 150'

DE = 14'

A

B

2.51.5

D

C

FEC FEC FECFEC

FEC

FE

C

FE

FE

FE

FE

C

DRYER CLO

1029A

DRYER CLO

1034A

VESTIBULE

1028A

VESTIBULE

1028B

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

LS101

VOLUME 3

M

AN

FI

R

ST

F L O

O R

P

LA

N

LI

FE

S

AF

ET

Y

A

IT

B A

R

RA

CK

S

CO

M

PL

EX

PH

A

SE

3 0

M

A N

N O

R

FO

LK

D

I S

TR

IC

T

N O

R

FO

LK

, V

A

R C

N

EA

M

D

AG

D G

G

A

PR

PR

O

JE

C T

N U

M

BE

R

C O

N

TR

AC

T

N O

LS

1 0

1-

F O R

T L E

E, V

I R G

IN

I A

16'0' 32' 48'

SCALE: 1/16" = 1' - 0"

NO SCALE

NORTH

KEY PLAN

'A' 'B' 'C'

1/16" = 1'-0"

300 MAN - FIRST FLOOR PLAN - LIFE SAFETY

M

AR

K D

ES

C

R

IP

TI

O

N D

DN

DN

OCCUPANT LOAD

EGRESS ROUTE DISTANCE (IN FEET)

TD = TRAVEL DISTANCE TO EXIT

CP = COMMON PATH OF TRAVEL

DE = DEAD END

25 C

EXIT

(NOT ALL EXITS ARE ACCESSIBLE)

ACCESSIBLE EXIT

TD = 150'

EXIT CAPACITY, CAPACITY OF DOOR

OR OTHER EGRESS COMPONENT

EXC

EXIT LOAD, NUMBER OF OCCUPANTS

UTILIZING EGRESS COMPONENT

EXL

FIRE EXTINGUISHER LOCATION

E

1 HOUR FIRE BARRIER

1/2 HOUR FIRE BARRIER

FIRE AND LIFE SAFETY LEGEND

FE

FEC FIRE EXTINGUISHER CABINET

LOCATION

1/2 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

2 HOUR FIRE BARRIER

1 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

2 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

STAIRS #1

2PN

3PN

3PN

3PN

3PN

2PN

LAUNDRY

STAIRS #2

2PN

2PN

3PN

3PN

3PN

3PN

2PN

CORRIDOR

DAY ROOM

JAN #2

RESTROOM

2010A

LUGGAGE

MECHANICAL

JAN

COMP STO

DAY ROOM

2PN

3PN

3PN

3PN

3PN

2PN

2PN

STAIRS #3

2PN

3PN

3PN

3PN

3PN

2PN

LAUNDRY

COMM

CORRIDOR

2PN

2PN

2PN

2PN

COMPUTER

LEARNING

PLT SGT OFFICE

ELEC

STORAGE

ELEVATOR

E1

LOBBY

TD = 110'

EXC = 165

EXL = 44

26 C

EXC = 165

EXL = 44

22 C

21 C

25 C

TD = 110' DE = 14'

EXC = 165

EXL = 85

A

B

2.51.5

D

C

CLOSET

FEC FEC

FE

DRYER CLO

2017A

DRYER CLO

2014A

FECFEC

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

LS102

VOLUME 3

M

AN

SE

C O

N D

F

LO

O R

P

LA

N

LI

FE

S

AF

E T Y

A

IT

B A

R

RA

CK

S

CO

M

PL

EX

PH

A

SE

3 0

M

A N

N O

R

FO

LK

D

I S

TR

IC

T

N O

R

FO

LK

, V

A

R C

N

EA

M

D

AG

D G

G

A

PR

PR

O

JE

C T

N U

M

BE

R

C O

N

TR

AC

T

N O

LS

1 0

2-

F O R

T L E

E, V

I R G

IN

I A

16'0' 32' 48'

SCALE: 1/16" = 1' - 0"

NO SCALE

NORTH

KEY PLAN

'A' 'B' 'C'

1/16" = 1'-0"

300 MAN - SECOND FLOOR PLAN - LIFE SAFETY

M

AR

K D

ES

C

R

IP

TI

O

N D

DN DN

OCCUPANT LOAD

EGRESS ROUTE DISTANCE (IN FEET)

TD = TRAVEL DISTANCE TO EXIT

CP = COMMON PATH OF TRAVEL

DE = DEAD END

25 C

EXIT

(NOT ALL EXITS ARE ACCESSIBLE)

ACCESSIBLE EXIT

TD = 150'

EXIT CAPACITY, CAPACITY OF DOOR

OR OTHER EGRESS COMPONENT

EXC

EXIT LOAD, NUMBER OF OCCUPANTS

UTILIZING EGRESS COMPONENT

EXL

FIRE EXTINGUISHER LOCATION

E

1 HOUR FIRE BARRIER

1/2 HOUR FIRE BARRIER

FIRE AND LIFE SAFETY LEGEND

FE

FEC FIRE EXTINGUISHER CABINET

LOCATION

1/2 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

2 HOUR FIRE BARRIER

1 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

2 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

OPEN TO MECH. RM. BELOW

STAIRS #1

2PN

3PN

3PN

3PN

3PN

2PN

LAUNDRY

2PN

2PN

3PN

3PN

3PN

3PN

2PN

CORRIDOR

DAY ROOM

JAN #2

RESTROOM

3010A

LUGGAGE

JAN

COMP STO

DAY ROOM

2PN

3PN

3PN

3PN

3PN

2PN

2PN

STAIRS #3

2PN

3PN

3PN

3PN

3PN

2PN

LAUNDRY

COMM

CORRIDOR

2PN

2PN

2PN

2PN

COMPUTER

LEARNING

PLT SGT OFFICE

ELEC

TD = 110'

26 C 22 C

21 C

25 C

TD = 110' DE = 14'

STAIRS #2

LOBBY

EXC = 165

EXL = 85

A

B

2.51.5

EXC = 165

EXL = 44

EXC = 165

EXL = 44

STORAGE

ELEVATOR

E1

CLOSET

FEC FEC

DRYER CLO

3016A

DRYER CLO

3014A

FECFEC

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

LS103

VOLUME 3

M

AN

TH

I R D

F L O

O R

P

LA

N

LI

FE

S

AF

ET

Y

A

IT

B A

R

RA

CK

S

CO

M

PL

EX

PH

A

SE

3 0

M

A N

N O

R

FO

LK

D

I S

TR

IC

T

N O

R

FO

LK

, V

A

R C

N

EA

M

D

AG

D G

G

A

PR

PR

O

JE

C T

N U

M

BE

R

C O

N

TR

AC

T

N O

LS

1 0

3-

F O R

T L E

E, V

I R G

IN

I A

16'0' 32' 48'

SCALE: 1/16" = 1' - 0"

NO SCALE

NORTH

KEY PLAN

'A' 'B' 'C'

1/16" = 1'-0"

300 MAN - THIRD FLOOR PLAN - LIFE SAFETY

M

AR

K D

ES

C

R

IP

TI

O

N D

DN DN

OCCUPANT LOAD

EGRESS ROUTE DISTANCE (IN FEET)

TD = TRAVEL DISTANCE TO EXIT

CP = COMMON PATH OF TRAVEL

DE = DEAD END

25 C

EXIT

(NOT ALL EXITS ARE ACCESSIBLE)

ACCESSIBLE EXIT

TD = 150'

EXIT CAPACITY, CAPACITY OF DOOR

OR OTHER EGRESS COMPONENT

EXC

EXIT LOAD, NUMBER OF OCCUPANTS

UTILIZING EGRESS COMPONENT

EXL

FIRE EXTINGUISHER LOCATION

E

1 HOUR FIRE BARRIER

1/2 HOUR FIRE BARRIER

FIRE AND LIFE SAFETY LEGEND

FE

FEC FIRE EXTINGUISHER CABINET

LOCATION

1/2 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

2 HOUR FIRE BARRIER

1 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

2 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

STAIRS #1

2PN

3PN

3PN

3PN

3PN

2PN

LAUNDRY

STAIRS #2

2PN

2PN

3PN

3PN

3PN

3PN

2PN

CORRIDOR

DAY ROOM

JAN. #2

RESTROOM

4010A

ELEC

LUGGAGE

3PN

JAN

COMP STO

DAY ROOM

2PN

3PN

3PN

3PN

3PN

2PN

2PN

STAIRS #3

2PN

3PN

3PN

3PN

3PN

2PN

LAUNDRY

COMM

CORRIDOR

LOBBY

2PN

2PN

2PN

2PN

COMPUTER

LEARNING

PLT SGT OFFICE

3PN

3PN

3PN

TD = 110'

26 C 22 C

21 C

25 C

TD = 110' DE = 14'

EXC = 165

EXL = 89

A

B

2.51.5

EXC = 165

EXL = 48

EXC = 165

EXL = 48

STORAGE

ELEVATOR

E1

CLOSET

FEC FEC

DRYER CLO

4020A

DRYER CLO

4014A

FECFEC

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

LS104

VOLUME 3

M

AN

FO

U R

TH

F

LO

O

R P

LA

N

LI

FE

S

AF

E T

Y

A

IT

B A

R

RA

CK

S

CO

M

PL

EX

PH

A

SE

3 0

M

A N

N O

R

FO

LK

D

I S

TR

IC

T

N O

R

FO

LK

, V

A

R C

N

EA

M

D

AG

D G

G

A

PR

PR

O

JE

C T

N U

M

BE

R

C O

N

TR

AC

T

N O

LS

1 0

4-

F O R

T L E

E, V

I R G

IN

I A

16'0' 32' 48'

SCALE: 1/16" = 1' - 0"

NO SCALE

NORTH

KEY PLAN

'A' 'B' 'C'

1/16" = 1'-0"

300 MAN - FOURTH FLOOR PLAN - LIFE SAFETY

M

AR

K D

ES

C

R

IP

TI

O

N D

DN

OCCUPANT LOAD

EGRESS ROUTE DISTANCE (IN FEET)

TD = TRAVEL DISTANCE TO EXIT

CP = COMMON PATH OF TRAVEL

DE = DEAD END

25 C

EXIT

(NOT ALL EXITS ARE ACCESSIBLE)

ACCESSIBLE EXIT

TD = 150'

EXIT CAPACITY, CAPACITY OF DOOR

OR OTHER EGRESS COMPONENT

EXC

EXIT LOAD, NUMBER OF OCCUPANTS

UTILIZING EGRESS COMPONENT

EXL

FIRE EXTINGUISHER LOCATION

E

1 HOUR FIRE BARRIER

1/2 HOUR FIRE BARRIER

FIRE AND LIFE SAFETY LEGEND

FE

FEC FIRE EXTINGUISHER CABINET

LOCATION

1/2 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

2 HOUR FIRE BARRIER

1 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

2 HOUR HORIZONTAL FIRE BARRIER

AT FLOOR/CEILING ASSEMBLY

STAIRS #1

2PN

3PN

3PN

3PN

3PN

2PN

LAUNDRY

2PN

2PN

3PN

3PN

3PN

3PN

2PN

CORRIDOR

DAY ROOM

JAN #2

RESTROOM

5010A

LUGGAGE

MECHANICAL

JAN

COMP STO

DAY ROOM

2PN

3PN

3PN

3PN

3PN

2PN

2PN

STAIRS #3

2PN

3PN

3PN

3PN

3PN

2PN

LAUNDRY

COMM

CORRIDOR

2PN

2PN

2PN

2PN

COMPUTER

LEARNING

PLT SGT OFFICE

ELEC

TD = 110'

26 C 22 C

21 C

25 C

TD = 110' DE = 14'

STAIRS #2

LOBBY

EXC = 165

EXL = 85

A

B

2.51.5

EXC = 165

EXL = 44

EXC = 165

EXL = 44

STORAGE

ELEVATOR

E1

EL EQ

FEC FEC

FE

DRYER CLO

5017A

DRYER CLO

5014A

FECFEC

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

LS105

VOLUME 3

M

AN

FI

FT

H

F

LO

O R

P

LA

N

LI

FE

S

AF

ET

Y

A

IT

B A

R

RA

CK

S

CO

M

PL

EX

PH

A

SE

3 0

M

A N

N O

R

FO

LK

D

I S

TR

IC

T

N O

R

FO

LK

, V

A

R C

N

EA

M

D

AG

D G

G

A

PR

PR

O

JE

C T

N U

M

BE

R

C O

N

TR

AC

T

N O

LS

1 0

5-

F O R

T L E

E, V

I R G

IN

I A

16'0' 32' 48'

SCALE: 1/16" = 1' - 0"

NO SCALE

NORTH

KEY PLAN

'A' 'B' 'C'

1/16" = 1'-0"

300 MAN - FIFTH FLOOR PLAN - LIFE SAFETY

M

AR

K D

ES

C

R

IP

TI

O

N D

GENERAL NOTES

1. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER DRAWINGS. COORDINATE

THE WORK OF OTHER TRADES INCLUDING, BUT NOT LIMITED TO THE REQUIREMENTS FOR

SLEEVES, INSERTS, HOLES, HANGERS AND ANCHORS.

2. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [+/-X'-X"] REFERENCED TO

THE FINISHED FLOOR TOP OF SLAB ELEVATION DATUM SET AT +0'-0". THIS DATUM IS EQUIVALENT

TO THE TOP OF SLAB ELEVATION INDICATED ON THE CIVIL DRAWINGS.

3. THE CONTRACTOR SHALL REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT

DRAWINGS TO THE CONTRACTING OFFICER PRIOR TO BEGINNING WORK IN AREAS THAT WILL

BE AFFECTED.

4. DETAILS ENTITLED OR NOTED AS "TYPICAL" APPLY NOT ONLY WHERE SPECIFICALLY

INDICATED OR REFERENCED, BUT ALSO IN ALL OTHER CASES WHERE THE NATURE OF THE

CONSTRUCTION REQUIRES THEIR USE. DETERMINE APPLICABILITY OF TYPICAL DETAILS FROM

DESCRIPTIVE TITLES OR FROM THE SIMILARITY OF A CONSTRUCTION CONDITION TO ANOTHER

CONDITION WHERE THE DETAIL IS SPECIFICALLY INDICATED OR REFERENCED.

5. THE STRUCTURAL DRAWINGS CONTAINED HEREIN REPRESENT THE FINISH STRUCTURE.

PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AND HOLD THE

STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK, INCLUDING CONNECTIONS,

IS COMPLETE. THE ANALYSIS, DESIGN, SAFETY, ADEQUACY AND INSPECTION OF ERECTION

BRACING, SHORING, AND OTHER TEMPORARY SUPPORTS ARE THE SOLE RESPONSIBILITY OF

THE CONTRACTOR.

6. CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND SUPERVISION OF THE

WORK ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR UON.

7. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP DRAWINGS UNDER

ANY CIRCUMSTANCES.

DESIGN CRITERIA

1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE FOLLOWING CODES AND

SPECIFICATIONS:

A. 2012 INTERNATIONAL BUILDING CODE

B. ASCE 7-10, MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES

C. AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" DATED 2010

D. ACI 318-11, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE

E. SJI "STANDARD SPECIFICATIONS FOR OPEN WEB STEEL JOISTS, K-SERIES", EFFECTIVE

MARCH 1, 2005

F. UFC 4-010-01 CHANGE 1 DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS (2013)

G. UFC 3-310-04 SEISMIC DESIGN OF BUILDINGS (2013)

H. UFC 3-301-01 CHANGE 1 STRUCTURAL ENGINEERING (2014)

I. UFC 4-023-03 CHANGE 2 DESIGN OF BUILDINGS TO RESIST PROGRESSILVE

COLLAPSE (2013)

2. DESIGN LOAD CRITERIA:

A. RISK CATEGORY II

B. LIVE LOADS:

ROOF 20 PSF

CORRIDOR 100 PSF

LIVING SPACE 60 PSF

COMPUTER/DAY/LAUNDRY/COMMON ROOMS100 PSF

MECHANICAL ROOMS 125 PSF

MOVABLE PARTITION LOAD NOT REQUIRED FOR THIS OCCUPANCY BY IBC

LIVE LOAD REDUCTION NOT PERMITTED

C. SNOW LOAD:

GROUND SNOW LOAD, Pg 15 PSF

SNOW LOAD IMPORTANCE FACTOR, I 1.0

SNOW EXPOSURE FACTOR, Ce 1.0 THERMAL FACTOR, Ct 1.1

ROOF SNOW LOAD 15 PSF

D. WIND LOADS:

WIND IMPORTANCE FACTOR, I 1.0

BASIC WIND SPEED, V 115 MPH

WIND EXPOSURE CATEGORY D

INTERNAL PRESSURE COEFFICIENTS, GCpi +/-0.18

E. SEISMIC LOADS:

SEISMIC IMPORTANCE FACTOR, I 1.0

SPECTRAL RESPONSE ACCELERATION, Ss 0.13g SPECTRAL RESPONSE ACCELERATION, S1 0.05g

SITE CLASS D

DESIGN SPECTRAL ACCELERATION, SDs 0.16g DESIGN SPECTRAL ACCELERATION, SD1 0.08g

SEISMIC DESIGN CATEGORY B

ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE

BASIC SEISMIC-FORCE-RESISTING SYSTEM LIGHT FRAMED STEEL

WITH FLAT STRAPPED BRACING

RESPONSE MODIFICATION FACTOR, R 4.0

SEISMIC RESPONSE COEFFICIENT Cs 0.04

DESIGN BASE SHEAR 292.6K

F. FROST DEPTH 14"

GEOTECHNICAL & FOUNDATION NOTES

1. GEOTECHNICAL INFORMATION - REFER TO GEOTECHNICAL ENGINEERING REPORT TITLED

"REPORT OF SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING EVALUATION

FOR FY16 AIT BARRACKS COMPLEX PHASE 3" (GOVERNMENT GEOTECHNICAL REPORT), DATED

SEPTEMBER 2015, PREPARED BY US ARMY CORPS OF ENGINEERS NORFOLK DISTRICT.

2. REMOVAL AND BACKFILLING OPERATIONS OF UNCONTROLLED FILL AND OVER EXCAVATION

SHALL BE PERFORMED UNDER THE SUPERVISION OF A PROFESSIONAL ENGINEER LICENSED

IN THE COMMONWEALTH OF VIRGINIA. THE PROFESSIONAL ENGINEER OVERSEEING THESE

OPERATIONS SHALL CERTIFY TO THE GOVERNMENT THAT ALL UNCONTROLLED FILL HAS

BEEN REMOVED AND REPLACED WITH PROPERLY COMPACTED STRUCTURAL FILL MEETING

THE PROJECT REQUIREMENTS.

3. REFER TO THE GOVERNMENT GEOTECHNICAL REPORT FOR NON-EXPANSIVE FILL, SELECT

FILL, AND SELECT CLAY FILL MATERIAL DEFINITIONS AND REQUIREMENTS, AND FOR

COMPLETE FILL AND SUB-GRADE PREPARATION MINIMUM REQUIREMENTS.

4. THE FOUNDATIONS CONSIST OF A CONCRETE MAT FOUNDATION WITH THICKENED AREAS

AND A SYSTEM OF SHALLOW SPREAD FOOTINGS.

5. NET ALLOWABLE DESIGN BEARING PRESSURE: 3,000 PSF

6. DO NOT CONSTRUCT FOUNDATIONS UNTIL FOUNDATION WORK HAS BEEN COORDINATED

WITH UNDERGROUND UTILITIES AND STRUCTURES.

7. COORDINATE AND VERIFY ALL FOOTING LOCATIONS WITH CIVIL, PLUMBING, AND ELECTRICAL

DRAWINGS.

8. ALL FOUNDATIONS AND SLABS ON GRADE SHALL REST ON A 6" MINIMUM LAYER OF

COMPACTED 57 STONE POROUS FILL UPON THE PREPARED SUB-GRADE.

MASONRY CONSTRUCTION NOTES

1. ALL MASONRY CONSTRUCTION SHALL BE IN ACCORDANCE WITH "BUILDING CODE

REQUIREMENTS FOR MASONRY STRUCTURES" (ACI 530.1-05/ASCE 6-05/TMS 402-05).

2. DESIGN MASONRY ASSEMBLAGE STRENGTH, f'm = 1500 PSI. NET AREA COMPRESSIVE

STRENGTH OF CONCRETE MASONRY UNITS SHALL BE A MINIMUM OF 1900 PSI.

3. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 AND BE MANUFACTURED WITH

LIGHT WEIGHT AGGREGATE.

4. GROUT SHALL CONFORM TO ASTM C476 AND SHALL NOT CONTAIN ADMIXTURES. GROUT

SHALL ATTAIN A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 2000 PSI.

5. GROUT POURS SHALL BE STOPPED 1-1/2 INCHES BELOW THE TOP OF A COURSE TO FORM A

KEY AT POURED JOINTS.

6. REINFORCEMENT SHALL BE DEFORMED BARS CONFORMING TO ASTM A615/A615M, GRADE 60

AND SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI 315. SHOP

FABRICATE REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.

7. LOCATE WIRE JOINT REINFORCEMENT 16 INCHES ON CENTER VERTICALLY.

8. PLACES PIPES AND CONDUITS PASSING HORIZONTALLY THROUGH MASONRY IN STEEL, PVC

SLEEVES OR CORED HOLES UON ON THE DRAWINGS.

9. ALUMINUM CONDUITS, PIPES, AND ACCESSORIES SHALL NOT BE EMBEDDED IN MASONRY

GROUT, OR MORTAR, UNLESS EFFECTIVELY COATED OR COVERED TO PREVENT ALUMINUM-

CEMENT CHEMICAL REACTION OR ELECTROLYTIC REACTION BETWEEN ALUMINUM AND STEEL.

10. UON OR DETAILED, CENTER WALL REINFORCEMENT IN BLOCK CELLS. A MINIMUM OF 1/2"

CLEARANCE IS TO BE PROVIDED BETWEEN REINFORCEMENT AND BLOCK CELL WALL. USE

GALVANIZED "Z" TYPE BAR POSITIONERS AT A MAXIMUM SPACING OF 2'-0" OC TO SECURE THE

VERT REINF STEEL PRIOR TO GROUTING THE CELL.

11. PROVIDE DOWEL REINFORCEMENT FROM FOUNDATION OF SAME SIZE AND SPACING AS

VERTICAL WALL REINFORCEMENT. LAP WALL REINFORCEMENT A MINIMUM OF 72 BAR

DIAMETERS.

12. PROVIDE INSPECTION OPENINGS AT THE BOTTOM OF ALL GROUTED CELL LOCATIONS.

13. ALL CMU SHALL BE 8" UON, REINFORCED WITH #4 VERT @ 24" O.C. MIN. PROVIDE

CONTINUOUS (1)-#5 REINFORCED BOND BEAM AT ROOF, TOP OF WALL, TOP OF FOOTING, AND

INTERMEDIATE AT 8'-0" OC MAX VERTICAL SPACING. PROVIDE BOND BEAM LINTEL ABOVE ALL

CMU OPENINGS IN ACCORDANCE WITH TYPICAL DETAL SHEET S-303.

CONCRETE CONSTRUCTION NOTES

1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF

THE AMERICAN CONCRETE INSTITUTE (ACI)

2. CAST-IN-PLACE CONCRETE SHALL ATTAIN THE MINIMUM 28-DAY COMPRESSIVE

STRENGTHS (f'c) OF:

4000 PSI ALL CONCRETE UON

3. CONCRETE DENSITY SHALL BE NORMAL WEIGHT UON ON DRAWINGS

4. CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM

A615/A615M, GRADE 60.

5. WELDED WIRE REINFORCEMENT SHALL CONFORM TO ASTM A185. PROVIDE SHEET-

TYPE WWR. SHEET LAPS SHALL BE TIED AND LAPPED ONE FULL MESH SPACING.

6. CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS OTHERWISE

INDICATED. CONTINUOUS REINFORCING STEEL SHALL BE LAPPED WITH TYPE "B"

SPLICES IN ACCORDANCE WITH THE REQUIREMENTS OF ACI 318.

7. MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS INDICATED. IN NO

CASE SHALL REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF ACI 301.

A. CONCRETE DEPOSITED AGAINST THE GROUND:3"

B. CONCRETE EXPOSED TO EARTH OR WEATHER:2"

C. INTERIOR ELEVATED FLOOR: TOP 3/4"

BOT 1 1/2"

D. SLAB ON GRADE REINF. DEPTH 1-1/2" FROM TOP OF SLAB

8. CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A 90-DEGREE

HOOK UNLESS OTHERWISE NOTED. STIRRUP, TIE AND 180-DEGREE HOOKS AND 90-

DEGREE HOOKS SHALL CONFORM TO THE REQUIREMENTS OF ACI 318.

9. PROVIDE 1/2" THICK PRE-MOLDED JOINT FILLER MATERIAL WHERE SLABS ON GRADE

ABUT VERTICAL SURFACES.

10. ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED, AND

MAINTAINED SECURELY IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.

ALL PIPING PASSING THROUGH ELEVATED FLOOR SLABS SHALL BE SLEEVED TO

ALLOW FOR MAINTENANCE AND REPLACEMENT.

11. REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, TIEBACKS, RECESSES AND

OTHER EMBEDDED ITEMS UNLESS OTHERWISE INDICATED. REINFORCEMENT SHALL NOT

BE CUT TO FACILIATE PLACEMENT OF EMBEDDED ITEMS.

12. NO CONCRETE SHALL BE PLACED UNTIL THE CONTRACTING OFFICER OR THE

CONTRACTING OFFICER'S DESIGNATED REPRESENTATIVE HAS INSPECTED ALL

EMBEDDED WORK, INCLUDING REINFORCEMENT.

13. ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 3/4" UON

14. ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE UNLESS

EFFECTIVELY COATED OR COVERED TO PREVENT ALUMINUM-CONCRETE REACTION AND

ELECTROLYTIC ACTION BETWEEN ALUMINUM AND STEEL.

STEEL JOIST CONSTRUCTION NOTES

1. K-SERIES OPEN WEB STEEL JOISTS SHALL BE IN ACCORDANCE WITH THE 2005 EDITION

OF THE STEEL JOIST INSTITUTE (SJI) "STANDARD SPECIFICATIONS FOR OPEN WEB

STEEL JOISTS, K-SERIES" AND "STANDARD LOAD TABLE, K-SERIES." JOISTS SHALL BE

HANDLED AND ERECTED IN ACCORDANCE WITH SJI TECHNICAL DIGEST #9 THIRD

EDITION DATED MARCH 2008.

2. JOIST BRIDGING SHALL CONFORM TO SJI SPECIFICATIONS, INCLUDING BRIDGING

REQUIRED FOR UPLIFT RESISTANCE. CROSS BRIDGING IS REQUIRED AT CHANGES IN

JOIST DEPTHS AND WHERE BRIDGING LINES ARE INTERRUPTED BY STRUCTURAL

STEEL BEAMS SPANNING PARALLEL TO THE JOISTS. WHERE BRIDGING TERMINATES

INTO A WALL, PROVIDE HORIZONTAL BRIDGING IN THE SPACE BETWEEN THE WALL AND

FIRST JOIST.

3. NO LOADS ARE PERMITTED TO BE SUPPORTED FROM JOIST BRIDGING.

4. JOISTS WITH CONCENTRATED LOADS ON THE TOP OR BOTTOM CHORDS NOT

LOCATED AT A PANEL POINT SHALL BE REINFORCED WITH A FIELD INSTALLED MEMBER.

THE FIELD INSTALLED MEMBER SHALL BE LOCATED AT THE CONCENTRATED LOAD AND

SHALL BRACE THE CHORD BACK TO A PANEL POINT IN ACCORDANCE WITH DETAIL

9/S-305.

5. NON-SLOPING STANDARD JOIST SEAT IS TO BE 2 1/2" DEEP UON.

ATFP CONSTRUCTION NOTES

1. THE DESIGN LEVEL OF THREAT IS LOW

2. DESIGN LEVEL OF PROTECTION IS LOW

3. EACH BUILDING HAS BEEN DESIGNED PER CRITERIA SET FORTH IN UFC 4-010-01 (2012)

AND UFC 4-023-03 (2013)

4. CFMF SUPPORTING ELEMENTS FOR WALL OPENINGS (WINDOWS, DOORS, ETC.) HAVE

BEEN DESIGNED TO MEET UFC 4-010-01 CRITERIA

5. SEE S-002 FOR TYPICAL ELEVATIONS AND DETAILS AT WALL OPENINGS.

MEMBER SIZES SHALL BE AS SHOWN.

COLD-FORMED METAL FRAMING

CONSTRUCTION NOTES

1. COLD-FORMED STEEL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE

AMERICAN IRON AND STEEL INSTITUTE (AISI) "COLD-FORMED STEEL DESIGN MANUAL",

2002 EDITION, INCLUDING THE TRUSS DESIGN MANUAL AND THE NORTH AMERICAN

SPECIFICATION FOR THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS, 2001

EDITION INCLUDING 2004 SUPPLEMENT.

2. COLD-FORMED STEEL ROOF TRUSS FRAMING, ROOF OVER-FRAMING AND ROOF FRAMING

CONNECTION DESIGN SHALL BE DELEGATED TO THE CONTRACTOR. SUBMIT

CALCULATIONS ALONG WITH THE SHOP DRAWINGS. DESIGN, INCLUDING DETERMINATION

OF ALL APPLICABLE LOADS, SHALL BE BASED ON REQUIREMENTS OF ASCE 7-10,

UFC 4-010-01, "DOD MINIMUM ANTI-TERRORISM STANDARDS FOR BUILDINGS" AND

UFC 4-023-03 "DESIGN OF BUILDINGS TO RESIST PROGRESSIVE COLLAPSE". SEALED

CALCULATIONS AND DRAWINGS SHALL BE SUBMITTED BY A REGISTERED PROFESSIONAL

ENGINEER LICENSED IN THE STATE OF VIRGINIA AND APPROVED PRIOR TO ORDERING

MATERIALS. DELEGATED DESIGN RESPONSIBILITY SHALL BEGIN AT HI ROOF BEARING

(SINGLE STORY PORTION), AND AT TOP OF CONTINUOUS HSS, FIVE STORY STRUCTURE;

DELEGATED DESIGN SHALL INCLUDE ALL FRAMING ABOVE THIS POINT NECESSARY FOR

CONSTRUCTION OF ROOF AND SUPPORT OF ALL ASSOCIATED ARCHITECTURAL FEATURES.

3. CENTER TRUSSES PARALLEL TO X-BRACE FRAMES OVER THEIR WALL CENTER

LINES. INCLUDE A 2800 LBS FORCE, CONCURRENT WITH WIND LOADS, WHEN DESIGNING

BOTTOM CHORDS OF THE TRUSSES OVER THE BRACE FRAMES.

4. ALL MATERIAL MUST BE 18 GAGE OR GREATER IN THICKNESS AND SHALL HAVE A MINIMUM

YIELD STRENGTH OF Fy = 50 KSI.

5. MEMBER DESIGNATIONS SHALL BE AS FOLLOWS:A B C - D

A = WEB DEPTH (DECIMAL INCHES) X 100

B = SECTION TYPE

C = FLANGE WIDTH (DECIMAL INCHES) X 100

D = BASE METAL THICKNESS (MILS)

SECTION TYPES (B):

S = STUD AND JOIST SECTION WITH FLANGE STIFFENING RETURN LIPS

T = TRACK SECTIONS (NO STIFFENING RETURN LIPS)

U = CHANNEL AND CHANNEL STUDS (NO STIFFENING RETURN LIPS)

F = FURRING CHANNEL

EXAMPLES:

MEMBER WEB SECTION FLANGEBASE METAL

DESIGNATION DEPTH TYPE WIDTH THICKNESS

362S162-33 3-5/8" S 1-5/8" 33 MILS

400T125-68 4" T 1-1/4" 68 MILS

MINIMUM CONNECTION REQUIREMENTS FOR COLD-FORMED WALL MEMBERS ARE AS

FOLLOWS, UNLESS OTHERWISE NOTED:

CONDITION CONNECTION

STUD TO TRACK (2) #10-16 SELF-DRILLING SCREWS WITH STUD

SECURELY SEATED INTO TRACK

TRACK TO STEEL BEAM 1/8" WELD EACH SIDE, 2" LONG SPACED AT 32" OC OR

(2) 0.145" DIAMETER POWDER ACTUATED FASTENERS

AT 16" OC

EXTERIOR STUD TRACK AISI 1021 3/16" DIAMETER CONCRETE SCREWS @ 2'-8"

TO CONCRETE SLAB OR THROUGH TRACK. PROVIDE 1 1/2" MINIMUM

FOUNDATION FOUNDATION EMBEDMENT. MINIMUM SPACING = 4".

CONCRETE EDGE DISTANCE = 3"

STUD TO STUD (2) #10 SDS @ 1'-4" OC

STEEL DECK TO TRACK SEE NOTES S-003

6. DEFLECTION OF WALL STUD SPANS FOR LATERAL LOADS SHALL NOT EXCEED A LIMIT OF

L/600.

7. ALL CONNECTION SCREWS SHALL BE ZINC COATED.

8. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3, "STRUCTURAL WELDING CODE -

SHEET STEEL."

9. PROVIDE TEMPORARY BRACING AND GUYING OF COLD-FORMED METAL FRAMING TO

PROVIDE FOR THE SAFETY OF THE STRUCTURE AND WORK PERSONNEL. BRACING SHALL

REMAIN UNTIL NO LONGER REQUIRED FOR SAFE SUPPORT OF FRAMING.

10. FIELD MODIFICATIONS OF COLD-FORMED STEEL SYSTEMS SHALL NOT BE ALLOWED

WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER OF RECORD.

11. MAINTAIN 3/4" MINIMUM DISTANCE BETWEEN CENTERS OF CONNECTION SCREWS AND

3/4" MINIMUM DISTANCE FROM THE CENTER OF SCREW TO EDGE OF CONNECTED PART.

INSTALL FASTENERS FROM THINNER THROUGH THICKER MATERIAL.

12. MECHANICAL BRIDGING SHALL BE PLACED AT A MINIMUM OF THIRD POINTS ALONG STUD

SPAN FOR ALL LOAD BEARING, SHEAR AND EXTERIOR WALLS LESS THAN 15 FEET TALL,

BUT NOT GREATER THAN 4'-0" OC. BRIDGING SHALL BE IN PLACE PRIOR TO PLACING ANY

LOADS ON THE STUD WALLS.

13. THE CONNECTION OF NONSTRUCTURAL COLD-FORMED STEEL FRAMING SHALL BE

PROVIDED WITH SLIP TYPE CONNECTION WHICH WILL ALLOW FOR DEFLECTION OF THE

BUILDING FRAME.

14. TYPICAL EXTERIOR WALL STUD SHALL BE 6" DEEP.

15. LOAD BEARING WALL FRAMING AND X BRACE FRAMING SHALL ALIGN WITH FRAMING ON

THE BUILDING STORY ABOVE/BELOW.

16. CONTINUOUS HSS6X6 PROVIDED AT HI ROOF BEARING SERVES AS A CONTINUOUS PERIMETER

TIE FOR PROGRESSIVE COLLAPSE RESISTANCE. DESIGN OF INTERNAL LONGITUDINAL AND

TRANSVERSE TIES, AND THEIR CONNECTION TO THE PROVIDED PERIMETER AND VERTICAL

TIES AT ROOF LEVEL, TO MEET UFC 4-0023-03 REQUIREMENTS IS INCLUDED IN THE DELEGATED

DESIGN. SUBMIT THE CALCULATIONS AND DRAWINGS FOR INTERNAL TIE AND CONNECTION

DESIGN AS PART OF THE DELEGATED DESIGN SUBMITTAL IN NOTE 2.

STEEL CONSTRUCTION NOTES

1. FABRICATION AND ERECTION OF STRUCTURAL STEEL AND DESIGN OF CONNECTIONS SHALL

BE IN ACCORDANCE WITH THE AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS"

2010 EDITION AND THE AISC "CODE OF STANDARD PRACTICE FOR BUILDINGS AND

BRIDGES", 2010 EDITION.

2. UNLESS OTHERWISE NOTED, STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE

ABOVE LISTED AISC SPECIFICATION AND THE FOLLOWING:

A. SQUARE AND RECTANGULAR HSS ASTM A500, GRADE B, Fy = 46 KSI B. ROUND HSS ASTM A500, GRADE B, Fy = 42 KSI

C. WIDE-FLANGE SHAPES AND TEES ASTM A992

D. CHANNELS AND S-SHAPES ASTM A36/A36M

E. PLATES AND ANGLES ASTM A36/A36M

F. HIGH STRENGTH BOLTS ASTM 325

G. ANCHOR RODS W/ NUT AND WASHER ASTM F1554, GRADE 36 UON

H. THREADED ROD ASTM A36/A36M

3. ALL SHOP AND FIELD WELDING SHALL BE BY CERTIFIED WELDERS AND SHALL CONFORM

TO AWS STANDARDS. USE E70XX ELECTRODES UNLESS NOTED OTHERWISE. CURRENT

AWS CERTIFICATIONS SHALL BE AVAILABLE AT THE JOB SITE FOR REVIEW BY THE

CONTRACTING OFFICER'S REPRESENTATIVE.

4. UNLESS OTHERWISE NOTED MINIMUM WELD SIZE TO BE 1/4" FILLET WELD

5. CONFORM DIMENSIONAL TOLERANCES FOR WELDED CONSTRUCTION, DETAILS OF WELDS,

AND QUALITY OF WELDS WITH THE APPLICABLE REQUIREMENTS OF AWS D1.1 AND THE

CONTRACT DRAWINGS. CONTRACTOR SHALL VISUALLY INSPECT 100 PERCENT OF WELDS.

IN ADDITION, A MINIMUM OF 20 PERCENT OF WELDS SHALL BE RANDOMLY SELECTED AND

TESTED BY LIQUID PENETRANT. ALSO, 100 PERCENT OF FULL MOMENT WELDS ARE TO BE

TESTED BY ULTRASONIC METHODS.

6. ALL BOLTED CONNECTIONS, UON, SHALL USE HIGH STRENGTH BOLTS WITH HARDENED

CARBON STEEL WASHERS AS REQUIRED FOR THE CONNECTON LOADS.

7. FIELD CUTTING OF STRUCTURAL STEEL MEMBERS BY ANY TRADE SHALL NOT BE PERMITTED.

BOLT HOLES SHALL NOT BE CUT OR ENLARGED BY FLAME CUTTING IN THE FIELD.

8. ALL FIELD BOLTED SHEAR CONNECTIONS SHALL BE FULLY TENSIONED CONNECTIONS,

THREADS INCLUDED IN THE SHEAR PLANE.

9. CONNECTION DESIGN IS DELEGATED TO THE CONTRACTOR. THE FABRICATOR SHALL

SUBMITDETAILS AND CALCULATIONS SEALED BY A PROFESSIONAL ENGINEER IN THE STATE

OF VIRGINIA TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO DOING ANY WORK OR

ORDERING MATERIALS.

10. CONNECTIONS FOR AXIAL, SHEAR AND BENDING FORCES SHALL BE DESIGNED FOR THE

FACTORED CAPACITY OF THE CONNECTED MEMBER.

11. THE MINIMUM BOLT DIAMETER SHALL BE 3/4" UNLESS OTHERWISE NOTED.

12. SHOP OR FIELD SPLICES OF STRUCTURAL STEEL MEMBERS ARE PROHIBITED EXCEPT AS

SPECIFICALLY PERMITTED IN THE SPECIFICATIONS, AS INDICATED ON APPROVED

SUBMITTALS, AND AS SPECIFICALLY APPROVED ON SHOP DRAWINGS PRIOR TO FABRICATION.

13. PAINT ALL STEEL BELOW GRADE WITH TWO COATS OF COAL TAR EPOXY IN ACCORDANCE

WITH SSPC PAINT 16.

14. CONTRACTOR IS RESPONSIBLE FOR FURNISHING, DESIGNING AND INSTALLING SUPPORT

STEEL FOR THE SOLAR COLLECTOR ARRAY PER MANUFACTURER SPECIFICATION AND

COORDINATED WITH ARCHITECTURAL DRAWINGS.

15. CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING MISCELLANEOUS STEEL

REQUIRED TO SUPPORT DRAINS, FAN CURBS, OVERFLOW DRAINS, ACCESS HATCHES,

ACCESS PANELS, ETC. COORDINATE WITH ARCHITECTURAL DRAWINGS.

16. POST INSTALLED ANCHOR BOLTS SHALL BE ASTM A193, GRADE B7 OR APPROVED EQUAL.

ANCHORS MAY BE UNDERCUT OR EPOXY ADHESIVE TYPE. INSTALL PER MANUFACTURER'S

RECOMMENDATIONS. ANCHORS SHALL WITHSTAND LOAD INDICATED ON THE PLANS.

CONTRACTOR TO SUBMIT MANUFACTURER'S ANALYSIS AND DESIGN DATA, INCLUDING

ICC REPORT, SHOWING THAT THE ANCHOR BOLT SYSTEMS MEET THE ANCHOR FORCE

REQUIREMENTS IN ACCORDANCE WITH ACI 318 WITH APPENDIX D.

SLOPE SLOPE DIRECTION

DECK SPAN

INDICATES ELEVATION

REFERENCED TO

FINISH FIRST FLOOR

GRID REFERENCE LINE

STEEL

BRICK

CONCRETE MASONRY

UNIT

CONCRETE

GROUT

CAPILLARY WATER

BARRIER

EARTH FILL

CFMF OVER-FRAMING

LOAD BEARING CFMF

WALL

STRUCTURAL LEGEND

SYMBOL DESCRIPTION

[+/-X'-X"]

ABBREVIATIONS

ABBREVIATION

AB

AFF

ANR

APPROX

ARCH

ATFP

BC

BEJ

BM

BOC

BOS

BRG

BP

BRP

CFMF

CFS

CJ

CL

CLR

CMU

COL

CONN

CONC

CONT

COORD

DE

DIA

DIAG

DIM

DN

EA

EF

EJ

ELEV, EL

EOS

EQ

EW

EXT

FFE

FOB

FS

FTG

GA

HORIZ

HS

HSS

JBE

JS

JST

KB

KIPS (k)

LG

LLH

LLV

LSH

LSV

MAX

MECH

MFR

MIN

N/A

NIC

NO.

OC

OPP

PJF

PL

PLF

PSF

PSI

REINF

REJ

SCHED

SDS

SF

SHT

SIM

SPA

STD

T&B

TOC

TOF

TOM

TOS

TS

TYP

UON

VERT

WF

WP

WWF

WT

DESCRIPTION

ANCHOR BOLT

ABOVE FINISHED FLOOR

ANCHOR

APPROXIMATELY

ARCHITECTURAL

ANTI-TERRORISM AND FORCE

PROTECTION

BOTTOM CHORD

BUILDING EXPANSION JOINT

BEAM

BOTTOM OF CONCRETE

BOTTOM OF STEEL

BEARING

BEARING OR BASE PLATE

BRICK RELIEF PLATE

COLD-FORMED METAL FRAMING

COLD-FORMED STEEL

CONTROL JOINT

CENTER LINE

CLEAR

CONCRETE MASONRY UNIT

COLUMN

CONNECTION

CONCRETE

CONTINUOUS

COORDINATE

DECK EDGE

DIAMETER

DIAGONAL

DIMENSION

DOWN

EACH

EACH FACE

EXPANSION JOINT

ELEVATION

EDGE OF SLAB

EQUAL

EACH WAY

EXTENSION

FINISHED FLOOR ELEVATION

FACE OF BRICK

FOOTING STEP

FOOTING

GAGE

HORIZONTAL

HIGH STRENGTH

HOLLOW STRUCTURAL SHAPE

JOIST BEARING ELEVATION

JOIST SUBSTITUTE

JOIST

KNUCKLED BEAM

1000 POUNDS

LONG

LONG LEG HORIZONTAL

LONG LEG VERTICAL

LONG SIDE HORIZONTAL

LONG SIDE VERTICAL

MAXIMUM

MECHANICAL

MANUFACTURER

MINIMUM

NOT APPLICABLE

NOT IN CONTRACT

NUMBER

ON CENTER

OPPOSITE

PREMOLDED JOINT FILLER

PLATE

POUNDS PER LINEAR FOOT

POUNDS PER SQUARE FOOT

POUNDS PER SQUARE INCH

REINFORCEMENT

ROOF EXPANSION JOINT

SCHEDULE

SELF DRILLING SCREW

SPREAD FOOTING

SHEET

SIMILAR

SPACES/SPACED

STANDARD

TOP AND BOTTOM

TOP OF CONCRETE

TOP OF FOOTING

TOP OF MASONRY

TOP OF STEEL

THICKENED SLAB

TYPICAL

UNLESS OTHERWISE NOTED

VERTICAL

WALL FOOTING

WORKING POINT

WELDED WIRE FABRIC

WEIGHT

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

28010

S-001

VOLUME 3

G

EN

E R

AL

S

TR

U C

TU

R

A L N

O T E

S, D

ES

IG

N

LO

AD

S

A B

BR

E V

IA

TI

O N

S

A

IT

B A

R

RA

CK

S

CO

M

PL

EX

PH

A

SE

3 0

M

A N

N O

R

FO

LK

D

I S

TR

IC

T

N O

R

FO

LK

, V

A

JP

J

C

ES

LW

M

LW

M

A

PR

PR

O

JE

C T

N U

M

BE

R

C O

N

TR

AC

T

N O

S S -

1-

6- 0 2

-0

B a ck ch ec k

F O R

T L E

E, V

I R G

IN

I A

M

AR

K D

ES

C

R

IP

TI

O

N D

STEEL HEADER

SEE PLAN

TRACK SEE SCHED

DOORS

WINDOWS

TYPICAL WALL ELEVATION

INTERIOR

OPENING WITH STEEL HEADER

JAMB

STUDS (TYP)

JAMB

STUDS (TYP)

JOIST BRG

ADD (1) STUD

ADJACENT TO

EA POST

LAP TRACK

0' - 6" TYP

4/S-505 SIM

POST SEE

S-002

S-002

S-002

S-002

S-002

S-002

S-002

S-002

S-002

S-002

S-002

S-002

6" THICK WALLS

600S WALL STUD

362S137-33 WEB STIFFENER

@ END BEARING

1/16"

1" EA FLANGE OF

WEB STIFFENER

(TYP)

SEE SCHEDULE

SEE…

This is the start of the file's text. The full file is on GovTribe.