THE SPECS FOR JFHQ SUPPLY MEZZANINE LOCKERS STORAGE AREA
Furnish and install quantity (50) wall locker type two tier lockers with a 4” high leveling bases These lockers are to match existing lockers within the UT ARNG in order to achieve standardization so if additional shelves or components are wanted in the future, this can be done without replacing the locker. Lockers shall be Qty (50) two tier, at least 36” deep x 24” wide by 72” high (2 opening) for an overall height of 76” with the 4” high base. Quantity (100) locker openings, each locker opening door shall have a hasp lock that allows the use of military issued padlocks. Each Locker opening shall have a minimum storage capacity of 18 cubic feet per locker opening. The doors shall be double welded mesh. The Single-Piece Welded Doors shall be formed from two (2) pieces of minimum 18-gauge [1.2] millimeter cold rolled steel box formed and welded together. One piece door with inner and outer door panels shall have a combined steel thickness of no less than [.096] inches or [2.4] millimeters thick. Welded door design with inner panel optimizes structural integrity of locker door system over and above any single frame door design. Exterior door panel shall be constructed with formed flanges and return flanges to add stiffness. Internal door panel shall be constructed with formed flanges for added stiffness. The doors shall have diamond perforated door patterns.
Hinges shall be 16-gauge full length hinge for increased strength and security of locker system. Hinges to be welded to door frame with spot welds not to exceed [6] inch or [152.4] millimeter separation. Door assembly to be riveted to door frame on factory pre-established hole pattern. There shall also be neoprene silencers on each door. The lockers shall be welded. The welded frame must consist of top, bottom, back, and sides constructed of a minimum of 18 – gauge [1.214] millimeters steel. All frame components shall be joined using resistance welding. Corner gussets shall be MIG and spot welded in each of the four front corners of the locker for increased stiffness and rigidity. Provide side panel lances evenly spaced on [3] inch or [76.2] millimeter centers. Side lances are placed on 3” centers to provide the flexibility of on-site, end-user reconfiguring/adding internal components anytime anywhere now or in the future. Provide four (4) [.875] inch or [22.23] millimeter diameter electrical knockouts per locker, two (2) located on top of the locker in both right and left rear corners, and two (2) located behind locker centered at a distance no greater than [24] inches or [609.6] millimeters from the top and bottom.
Knock- outs allow end-user flexibility of adding electrical capability to lockers. Provide a minimum of four (4) duplex receptacle electrical knockouts per locker; to be used with a modular electrical system as required. Top of the locker shall have four (4) duplex electrical knockouts. Top of locker shall have electrical duplex receptacle knockouts located on both right and left side of locker. Back panel of locker shall have a minimum of two (2) duplex electrical knockouts. Back of locker shall have electrical duplex receptacle knockouts located on both right and left side of locker and no farther than [24] inches or [609.6] millimeters from the top of the locker. Provide ventilation holes in top of locker to allow mechanically extracted air to be pulled up through the locker system as required. The Installation team must be factory trained and certified and is employed by the vendor and not to be a sub-contracted installation crew.
24” W x 36” D x 72” H (2 opening) Two tier lockers with Hasp locks- -Overall Height 76” Depth 36” deep
Two-piece welded mesh door: Adds strength and tamper resistance helping to reduce FLIPL’s
Integrated lance is placed on 3” centers in order to have the ability to add shelves in the future
Hasp Lock- Accepts standard military issued locks
The cabinet is welded
Factory Trained and Certified local installation
Green-guard Certified Lockers