Attachment D - JPLRND JPD-S Self Assessment Table (Permissions Removed).xlsx
XLSX spreadsheet 15 KB Posted
- Attached to
- RFI Evaluation of Available COTs Hand-Held/Wearable Joint Personal Dosimeter - Squad (JPD-S)
- Solicitation number
- W911SR-25-R-JPDS
About this file
This file is a self-assessment table for a Joint Personal Dosimeter - Squad (JPD-S) evaluation, part of a Request for Information (RFI) issued by the Department of the Army Materiel Command Army Contracting Command Aberdeen Proving Ground. The document provides a comprehensive checklist for potential vendors to assess their hand-held/wearable radiation detection devices against specific technical requirements across ten key areas: references and testing standards, performance characteristics, physical characteristics, operator information display, power specifications, materials, maintainability, natural environment tolerance, induced environment capabilities, and other qualification criteria.
The self-assessment matrix covers detailed technical specifications including compliance with multiple National Standards Institute (ANSI) testing standards, radiation detection sensitivities for neutron/gamma/beta radiation, device operability under various environmental conditions, electromagnetic interference resistance, and performance metrics such as detector technology, display features, power requirements, and durability. Vendors are expected to indicate whether they currently meet, plan to meet, or do not plan to meet each requirement, with opportunities to provide additional comments and demonstrate their product's alignment with military-grade radiation detection equipment specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| JPD S RFI.pdf | ||
| Attachment A -DoD TRL Extract.pdf | ||
| Attachment D - JPLRND JPD-S Self Assessment Table v2.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1 INSTRUCTIONS: Please check the appropriate box for how your system meets each requirement. While comments are not required, they are welcome. If you need additional space for comments please add a note to the comment section to see additional note.
| Notional Requirement ID | Notional Requirement | Already meet | Plan to meet | Do NOT plan to meet | Comments |
| 1.0 | References and Testing Standards (see P-Spec) | ||||
| Testing per National Standards Institute (ANSI) N13.11-2009 | Personnel dosimetry performance - criteria for testing | ||||
| Testing per National Standards Institute (ANSI) N42.17AC-2022 | Portable instrumentation for use in normal environmental conditions | ||||
| Testing per National Standards Institute (ANSI) N42.34-2021 | Performance Criteria for Handheld Instruments | ||||
| Testing per National Standards Institute (ANSI) N42.48-2018 | Requirements for Spectroscopic Personal Radiation Detectors (SPRDs) | ||||
| Testing per National Standards Institute (ANSI) N42.49 A (2011)/B (2013) | Criteria for Alarming Electronic Personal Emergency Radiation Detectors (PERDs) | ||||
| Testing per National Standards Institute (ANSI) N42.20-2003 | Performance Criteria for Active Personnel Radiation Monitors | ||||
| Testing per National Standards Institute (ANSI) N42.42-2020 | Data Format for Radiation Detectors | ||||
| MIL STD 810H | Environmental Engineering Consderations and Laboratory Tests | ||||
| MIL STD 461 | Control of the Electromagnetic Interference (EMI) Emission and Susceptibility | ||||
| 2.0 | Peformance (see P-Spec) | ||||
| Neutron Sensitivity/minimum and maximum detectable dose and dose rate levels | |||||
| Gamma Sensitivity/minimum and maximum detectable dose and dose rate levels | |||||
| Beta Sensitivity/minimum and maximum detectable dose and dose rate levels | |||||
| Radionuclide Library and isotope identification, if available | |||||
| operator setup time | |||||
| display type, autoranging, dynamic range and units | |||||
| display of dose equivalent rate and exposure rate | |||||
| Programmability | |||||
| memory type/size and volitility | |||||
| response time | |||||
| accuracy | |||||
| resettable accumulated dose | |||||
| Data Transfer | |||||
| measurement of prompt gamma/neutron | |||||
| alarms (visual/audible), user setable dose/dose rate, resetting, user restrictions | |||||
| survivability of nuclear event | |||||
| gamma energy filtering and rejection | |||||
| Calibration/Self-Calibration capability | |||||
| 3.0 | Physical characteristics | ||||
| Use with PPE, wet weather gear, cold weather gear | |||||
| clip or harness to facilitate wearing | |||||
| display type and illumination | |||||
| communication types and ports (BlueTooth, Optical, serial, USB, WiFi, etc.) | |||||
| gamma/neutron detector technology used (Scintillator/SiPM, GMT, Pin Diode, PT, etc.) | |||||
| Neutron moderation capability | |||||
| Hand-held Operation | |||||
| Human Factors | |||||
| temperature tolerance and correction | |||||
| batery type and if rechargable | |||||
| color | |||||
| weight | |||||
| Size/Dimensions | |||||
| vehicle or robotic platform mounting option | |||||
| 4.0 | Operator Information | ||||
| Display | |||||
| Confidence Indicator | |||||
| carrying case and type | |||||
| user maintenance requirements | |||||
| Controls | |||||
| 5.0 | Power | ||||
| Power Supply Replacement | |||||
| Capability to use remote power and/or recharge the power supply | |||||
| battery type/battery life/sleep mode/low power alarm | |||||
| Warm-up Time | |||||
| 6.0 | Materiels | ||||
| Case Materials | |||||
| Safety and Health/chemistry of internal components (MSDS) | |||||
| eqquipment and supplies | |||||
| 7.0 | Maintainability | ||||
| MTBF | |||||
| MTBM | |||||
| MCMT | |||||
| MTBOMF | |||||
| MTTR | |||||
| Radioactive Materials | |||||
| Hazardous Materials | |||||
| Explosive Threat | |||||
| Elcectrical Shock | |||||
| 8.0 | Natural Environment (Mil Std 810H) | ||||
| Temperature Operation | |||||
| Storage Temperatures | |||||
| Humidity | |||||
| Solar Radiation Susceptability | |||||
| Fungus | |||||
| Salt Water Spray and Salt Fog | |||||
| Rapid Decompression | |||||
| sand/dust wind speed versus dust particle size) | |||||
| Operating humidity | |||||
| Immersion/IP Rating | |||||
| Vibration | |||||
| Shelf Life | |||||
| 9.0 | Induced Environment | ||||
| Tested to Mil Std 461 - Electromagnetic Interference (EMI) | |||||
| Lightning Induced Transient Susceptibility Testing | |||||
| CBRN Contamination Survability | |||||
| Battlefield Contaminants | |||||
| Workmanship | |||||
| Tested to Mil STD 810H | |||||
| operation in explosive environment | |||||
| altitude | |||||
| 10.0 | Other | ||||
| Qualification testing comments | |||||
| Ordering Information comments | |||||
| Manufacturer/Vendor | |||||
| Product Name/Model | |||||
| Price Range |