W911SG25BA011 Bldg 112 Asbestos and Lead Surveys.pdf
PDF 2 MB Posted
- Attached to
- Building 112 Repair/Replace Roof
- Solicitation number
- W911SG25BA011
About this file
This is an asbestos and lead survey report for Building 112 at Fort Bliss, Texas, conducted by ENCON International, Inc. for Mr. Henry Wilson, Asbestos & Lead Manager at the Department of Public Works. The inspection was performed on April 16-17, 2008 under ENCON Project #103-08-083 prior to planned demolition or renovation activities. The survey was conducted in accordance with EPA NESHAP regulations (40 CFR Part 61, Subpart M) and Texas Asbestos Health Protection Rules (TAHPR).
The asbestos survey of the two-story, 6,831 square foot office building with basement involved collecting 63 bulk samples that were analyzed by Apex Precision Analytical Services using EPA Method 600/R-93/116. Results identified asbestos-containing materials (>1% asbestos) in 12" x 12" floor tiles/mastic/red flooring material (6,831 SF), pipe insulation on 4-inch (80 LF) and 8-inch (60 LF) pipes, and pipe insulation elbows for both 4-inch (12 each) and 8-inch (12 each) pipes. The lead-based paint inspection using a NITON XLp 303 AW X-Ray Fluorescence analyzer found that 72 out of 134 XRF readings tested at or above the 0.3 mg/cm² action level. The report includes detailed laboratory analysis results, sample location drawings, photo documentation, and chain of custody forms, with recommendations for proper notification and licensed removal prior to any demolition or renovation work.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E N C O N International, Inc.
Engineering, Environmental, & Technical Services
April 24, 2008
Mr. Henry Wilson Phone: (915) 568-2300
Asbestos & Lead Manager Fax: (915) 568-4304
DPW, Bldg. 777
Fort Bliss, TX 79916
RE: SUBMITTAL OF ASBESTOS & LEAD SURVEY REPORTS
Ft. Bliss Bldg. # 112
ENCON Project #103-08-083
Dear Mr. Wilson, This document summarizes the Asbestos & Lead Survey Report for the subject facility. The below-listed information was utilized to complete the Scope of Work Tasks:
Bldg No. 112 POC: N/A Phone No: N/A
Project Location and/or Room No. Whole Bldg.
Brief SOW:
Performed sampling prior to demolition or renovation activities.
ASBESTOS – A total of sixty-three (63) bulk samples were collected and submitted for analysis.
Results indicated asbestos present at or above EPA threshold limit of 1% in the following building material; 12” x 12” floor tiles/mastic/red flooring material, pipe insulation (4” & 8”), and pipe elbows insulation (4” & 8”).
LEAD – Results indicated that seventy-two (72) out of one-hundred-thirty-four (134) XRF readings tested were equal to or greater than the action level of 0.3 mg/cm
Technical Summary Were
Found
Were
Not
Found
Not
Tested
1. Asbestos Containing Materials (>1 %) X
2. Lead Based Paint Materials X
Contact me with any technical questions, or follow-up needs that you may have.
Sincerely:
Alex Woelper P.E.
Project Manager
Attachments:
Asbestos & Lead Survey Reports
El Paso Office: 7307 Remcon Circle, Suite 103 El Paso, Texas 79912 Fax 915-581-2049 Phone 915-833-3740
Engineering, Environmental & Technical Services
LIMITED ASBESTOS SURVEY
BUILDING 112
FORT BLISS, TEXAS 79916
Prepared for:
Mr. Henry Wilson, P.E.
DPW
Building 777
Fort Bliss, Texas 79916
Prepared by:
ENCON International, Inc.
7307 Remcon Circle, Suite 103
El Paso, Texas 79912
Date of Inspection:
April 17, 2008
ENCON Project No. 103-08-083
E
N C O N INTERNATIONAL, INC.
April 23, 2008
Mr. Henry Wilson, P.E. Phone: (915) 568-2300
Asbestos & Lead Manager Via email & hand delivery
DPW, Bldg. 777
RE: ASBESTOS SURVEY REPORT
Building 112
Dear Mr. Wilson, ENCON International, Inc., (ENCON) has submitted for your review the attached Asbestos
Survey Report. This Asbestos Survey was conducted in accordance with Asbestos National
Emissions Standards for Hazardous Air Pollutants (NESHAP): 40 CFR Part 61, Subpart M.
Sampling protocols were performed in accordance with the Texas Asbestos Health Protection
Rules (TAHPR).
This Asbestos Survey was properly performed by ENCON DSHS licensed personnel. ENCON’s personnel have been trained and are in compliance with Texas Department of State Health
Services (DSHS) regulations. If you have any questions regarding this Asbestos Survey, please feel free to contact us at your convenience.
Sincerely, Alex Woelper, P.E.
Program Manager
Asbestos Survey Report
Asbestos Drawings
Photo Log
Laboratory Documentation
E
N C O N INTERNATIONAL, INC.
Asbestos Survey Report ENCON International, Inc.
Ft. Bliss, Bldg. 112 Project No. 103-08-083
El Paso Office: 7307 Remcon Circle, Suite 103 El Paso, Texas 79912 Fax 915-581-2049 Phone 915-833-3740
ASBESTOS SURVEY REPORT
Ft. Bliss, Bldg. 112
SUMMARY
ENCON International, Inc. (ENCON) personnel performed an Asbestos Inspection of a structure designated as “Building 112” on Fort Bliss, Texas. The following are the field sample collection and analysis results for this inspection. The inspection was conducted to ensure compliance with
NESHAP – 40 CFR Part 61, Subpart M, which states that “prior to the commencement of the demolition or renovation, thoroughly inspect the affected facility or part of the facility where the demolition or renovation operation(s) will occur for the presence of asbestos, including Category
I and Category II non-friable ACM. ”
The sample collection and subsequent laboratory analytical results indicated that asbestos was identified in the following building materials:
ACM Description Estimated Quantities
12” x 12” floor tiles/mastic/red flooring material 6,831 SF
Pipe insulation (4 inch) 80 LF
Pipe insulation (8 inch) 60 LF
Pipe insulation elbows (4 inch) 12 ea.
Pipe insulation elbows (8 inch) 12 ea.
The quantities provided above are estimates only and should be field verified by the abatement contractor.
INTRODUCTION
This Asbestos Survey was performed by Mr. David Morales on April 16-17, 2008. This Asbestos
Survey was conducted in accordance with Asbestos National Emissions Standards for Hazardous
Air Pollutants (NESHAP): 40 CFR Part 61, Subpart M. Sampling protocols were performed in accordance with the Texas Asbestos Health Protection Rules (TAHPR). Building 112 was to undergo renovations and was visually inspected and it was determined that the suspect asbestos-containing materials could be divided into twenty-one (21) homogeneous areas, including the following: cove base mastic (3 types), 12” x 12” floor tile/mastic (3 types), textured drywall/joint
El Paso Office: 7307 Remcon Circle, Suite 103 El Paso, Texas 79912 Fax 915-581-2049 Phone 915-833-3740 compound (2 types), textured plaster (3 types), 2’ x 4’ ceiling panels, pipe insulation (2 types), pipe elbows (2 types), window caulking, door caulking, stairway tread texture, vinyl stair tread mastic, and vinyl landing tread mastic.
DESCRIPTION
Building 112 was being used as office space on Fort Bliss, Texas. The building occupied approximately 6,831 SF. The building was a two-story structure constructed with CMU walls on a concrete foundation. The building also had a basement that was being used for storage. The interior was partitioned with drywall walls. Most of the flooring was covered with various colors of floor tile and carpeting. A red cementitious material (ACM) was found under all flooring materials on the first and second floors. At the time this Asbestos Survey was performed, the date of construction was not known.
SAMPLING METHODOLOGY
A visual inspection of the building was conducted to develop a sampling plan. This included determining sample collection points, homogeneous materials and areas. Friability was assessed by manually manipulating the suspect asbestos materials utilizing hand pressure to determine if the materials, when dry, can be crumbled, pulverized, or reduced to powder. Twenty-one (21) homogeneous areas were established and at least three (3) samples were collected from each area. Areas that have suspect asbestos-containing surfacing, thermal systems insulation, or miscellaneous materials are to be considered homogeneous. These samples were each uniquely and individually identified and logged into a chain of custody document and prepared for shipment to a third-party independent laboratory for analysis. Building materials that are not considered suspect include the following; concrete, metal, glass, and wood. Destructive sampling was not authorized or performed to locate hidden or inaccessible materials.
SAMPLE ANALYSIS
Sixty-three (63) samples were submitted for analysis. Bulk PLM analysis was conducted utilizing the EPA Method 600/R-93/116. This method separates the sample material into various layers based on their morphology, and then the presence of the different asbestos fibers in each
El Paso Office: 7307 Remcon Circle, Suite 103 El Paso, Texas 79912 Fax 915-581-2049 Phone 915-833-3740 of these layers is detected. The analysis was performed by Apex Precision Analytical Services, Inc. located in Friendswood, TX. The term asbestos-containing material (ACM) is defined as a material that contains greater than 1% of any asbestiform varieties of Chrysotile, Amosite, Crocidolite, Tremolite, Anthophyllite, and Actinolite, or combinations of these materials.
Asbestos materials were determined by the July 1993 Environmental Protection Agency as recommended in document EPA/600/R-93/116 titled, "Method for the Determination of
Asbestos in Bulk Building Materials." Copies of the asbestos laboratory results and related documentation have been attached to this Report.
CONCLUSION
Proper notification should be made to the appropriate authorities prior to any asbestos abatement activity, renovation or operations and maintenance (O&M) activity affecting asbestos-containing building materials (ACBM), or any demolition in facilities or public buildings. The Texas DSHS
(§295.34 (a) (2)) states that if disturbance of friable and non-friable asbestos-containing building materials (ACBM) is anticipated, these materials shall be removed prior to performing any demolition or renovation activities by licensed and trained individuals according to methodology specified by §295.58-§295.60. A proper notification shall be submitted to the DSHS no less than
10 working days prior to commencement of abatement activity.
Contact the Asbestos Inspector listed below with any clarifications that may be needed.
Inspected by: Reviewed by:
David Morales Tim Jones
Asbestos Inspector Asbestos Consultant
License # 60-2735 License # 10-5575
E�CO� International, Inc.
Asbestos Sample Locations
E�CO� #: 103-08-083
Date: 4/24/2008 �.T.S
Bldg. 112 – 1st floor
Asbestos Sample Location Drawing
# = Asbestos Sample Location
# = Positive Asbestos Sample Location#
17 18
55-57 58-60 61-63
Asbestos Homogeneous Areas
E�CO� #: 103-08-083
Date: 4/24/2008 �.T.S
Bldg. 112 – 1st floor
Asbestos Homogeneous Areas Drawing
# = Asbestos Sample Location
# = Positive Asbestos Sample Location#
17 18
55-57 58-60 61-63
12" x 12" floor tile/mastic/ red flooring material
E�CO� #: 103-08-083
Date: 4/24/2008 �.T.S
Bldg. 112 – 2nd floor
Asbestos Sample Location Drawing
# = Asbestos Sample Location
# = Positive Asbestos Sample Location#
31-33
E�CO� #: 103-08-083
Date: 4/24/2008 �.T.S
Bldg. 112 – 2nd floor
Asbestos Homogeneous Areas Drawing
# = Asbestos Sample Location
# = Positive Asbestos Sample Location#
31-33
12" x 12" floor tile/mastic/ red flooring material
E�CO� #: 103-08-083
Date: 4/24/2008 �.T.S
Bldg. 112 – basement
Asbestos Sample Location Drawing
# = Asbestos Sample Location
# = Positive Asbestos Sample Location#
34-36
40 41
43-44
46-48
E�CO� #: 103-08-083
Date: 4/24/2008 �.T.S
Bldg. 112 – basement
Asbestos Homogeneous Areas Drawing
# = Asbestos Sample Location
# = Positive Asbestos Sample Location#
34-36
40 41
43-44
46-48
Pipe insulation/Pipe Elbows
Photo Log
East side of Building 112.
8” insulated pipe & pipe elbows.
PLM (Bulk) - Asbestos Analysis Report - Visual ID (EPA Method 600/R-93-116 Visual Area Estimation)
Client:
ENCON International Report Number: 5008-0930 7307 Remcon Circle, Suite 100 Report Date: April 17, 2008 El Paso, TX 79912 Samples Collected: April 16, 2008 915-833-3740 Date Received: April 17, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Fort Bliss, Building 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-01 5008-0930-01A Beige / Cove Base / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-01B White / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
S-02 5008-0930-02A Beige / Cove Base / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-02B White / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
S-03 5008-0930-03A Beige / Cove Base / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-03B White / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
S-04 5008-0930-04A Beige / 12 x 12 Floor Tile / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-04B Yellow / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-04C Red / Flooring / Fibrous / Homogeneous Chrysotile 3% Cellulose 3% Binder
S-05 5008-0930-05A Beige / 12 x 12 Floor Tile / NonFibrous / Homogeneous None Detected None Detected Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
NVLAP Lab Code: 200633-0 PLM TDSHS Asbestos Lab License#: 30-0312 PLM/PCM
Client:
ENCON International Report Number: 5008-0930 7307 Remcon Circle, Suite 100 Report Date: April 17, 2008 El Paso, TX 79912 Samples Collected: April 16, 2008 915-833-3740 Date Received: April 17, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Fort Bliss, Building 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-05 5008-0930-05B Yellow / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-05C Red / Flooring / Fibrous / Homogeneous Chrysotile 3% Cellulose 3% Binder
S-06 5008-0930-06A Beige / 12 x 12 Floor Tile / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-06B Yellow / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-06C Red / Flooring / Fibrous / Homogeneous Chrysotile 3% Cellulose 3% Binder
S-07 5008-0930-07A Off White,Blue / 12 x 12 Floor Tile / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-07B Beige / Floor Tile / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-07C Yellow / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-07D Red / Flooring / Fibrous / Homogeneous Chrysotile 3% Cellulose 3% Binder
S-08 5008-0930-08A Off White,Blue / 12 x 12 Floor Tile / NonFibrous / Homogeneous None Detected None Detected Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Client:
ENCON International Report Number: 5008-0930 7307 Remcon Circle, Suite 100 Report Date: April 17, 2008 El Paso, TX 79912 Samples Collected: April 16, 2008 915-833-3740 Date Received: April 17, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Fort Bliss, Building 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-08 5008-0930-08B Beige / Floor Tile / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-08C Yellow / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-8D Red / Flooring / Fibrous / Homogeneous Chrysotile 3% Cellulose 3% Binder
S-09 5008-0930-09A Off White,Blue / 12 x 12 Floor Tile / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-09B Beige / Floor Tile / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-09C Yellow / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-09D Red / Flooring / Fibrous / Homogeneous Chrysotile 3% Cellulose 3% Binder
S-10 5008-0930-10A White / Texture,Joint Compound / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-10B Tan,White / Drywall / Fibrous / Homogeneous None Detected Cellulose 10% Binder
S-11 5008-0930-11A White / Texture,Joint Compound / NonFibrous / Homogeneous None Detected None Detected Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Client:
ENCON International Report Number: 5008-0930 7307 Remcon Circle, Suite 100 Report Date: April 17, 2008 El Paso, TX 79912 Samples Collected: April 16, 2008 915-833-3740 Date Received: April 17, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Fort Bliss, Building 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-11 5008-0930-11B Tan,White / Drywall / Fibrous / Homogeneous None Detected Cellulose 10% Binder
S-12 5008-0930-12 White / Texture,Joint Compound / NonFibrous / Homogeneous None Detected None Detected Binder
S-13 5008-0930-13A Dark Grey / Cove Base / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-13B Yellow / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
S-14 5008-0930-14A Dark Grey / Cove Base / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-14B Yellow / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
S-15 5008-0930-15A Dark Grey / Cove Base / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-15B Yellow / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
S-16 5008-0930-16A White,Off White / Paint,Texture / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-16B White / Plaster / NonFibrous / Homogeneous None Detected None Detected Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Client:
ENCON International Report Number: 5008-0930 7307 Remcon Circle, Suite 100 Report Date: April 17, 2008 El Paso, TX 79912 Samples Collected: April 16, 2008 915-833-3740 Date Received: April 17, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Fort Bliss, Building 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-17 5008-0930-17A White,Off White / Paint,Texture / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-17B White / Plaster / NonFibrous / Homogeneous None Detected None Detected Binder
S-18 5008-0930-18A White,Off White / Paint,Texture / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-18B White / Plaster / NonFibrous / Homogeneous None Detected None Detected Binder
S-19 5008-0930-19 White,Grey / 2x4 Ceiling Tile / Fibrous / Homogeneous None Detected Cellulose
Fibrous Glass 25% 25% Binder
S-20 5008-0930-20 White,Grey / 2x4 Ceiling Tile / Fibrous / Homogeneous None Detected Cellulose
Fibrous Glass 25% 25% Binder
S-21 5008-0930-21 White,Grey / 2x4 Ceiling Tile / Fibrous / Homogeneous None Detected Cellulose
Fibrous Glass 25% 25% Binder
S-22 5008-0930-22A White,Green / Paint / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-22B Tan,White / Drywall / Fibrous / Homogeneous None Detected Cellulose 10% Binder
S-23 5008-0930-23A White,Green / Paint / NonFibrous / Homogeneous None Detected None Detected Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Client:
ENCON International Report Number: 5008-0930 7307 Remcon Circle, Suite 100 Report Date: April 17, 2008 El Paso, TX 79912 Samples Collected: April 16, 2008 915-833-3740 Date Received: April 17, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Fort Bliss, Building 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-23 5008-0930-23B Tan,White / Drywall / Fibrous / Homogeneous None Detected Cellulose 10% Binder
S-24 5008-0930-24A White / Texture,Joint Compound / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-24B Tan,White / Drywall / Fibrous / Homogeneous None Detected Cellulose
Fibrous Glass 10% 2% Binder
S-25 5008-0930-25A Brown / Cove Base / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-25B Off White, Black / Mastic,Material / NonFibrous / Homogeneous None Detected None Detected Binder
S-26 5008-0930-26A Brown / Cove Base / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-26B Off White, Black / Mastic,Material / NonFibrous / Homogeneous None Detected None Detected Binder
S-27 5008-0930-27A Brown / Cove Base / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-27B Off White, Black / Mastic,Material / NonFibrous / Homogeneous None Detected None Detected Binder
S-28 5008-0930-28A Off White,Blue / 12 x 12 Floor Tile / NonFibrous / Homogeneous None Detected None Detected Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Client:
ENCON International Report Number: 5008-0930 7307 Remcon Circle, Suite 100 Report Date: April 17, 2008 El Paso, TX 79912 Samples Collected: April 16, 2008 915-833-3740 Date Received: April 17, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Fort Bliss, Building 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-28 5008-0930-28B Yellow / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-28C Red / Flooring / Fibrous / Homogeneous None Detected Cellulose 3% Binder
S-29 5008-0930-29A Off White,Blue / 12 x 12 Floor Tile / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-29B Yellow / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-29C Red / Flooring / Fibrous / Homogeneous Chrysotile 3% Cellulose 3% Binder
S-30 5008-0930-30A Off White,Blue / 12 x 12 Floor Tile / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-30B Yellow / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0930-30C Red / Flooring / Fibrous / Homogeneous Chrysotile 3% Cellulose 3% Binder
S-31 5008-0930-31 White / Texture,Plaster / NonFibrous / Homogeneous None Detected None Detected Binder
S-32 5008-0930-32 White / Texture,Plaster / NonFibrous / Homogeneous None Detected None Detected Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Client:
ENCON International Report Number: 5008-0930 7307 Remcon Circle, Suite 100 Report Date: April 17, 2008 El Paso, TX 79912 Samples Collected: April 16, 2008 915-833-3740 Date Received: April 17, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Fort Bliss, Building 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-33 5008-0930-33 White / Texture,Plaster / NonFibrous / Homogeneous None Detected None Detected Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Client:
ENCON International Report Number: 5008-0958 7307 Remcon Circle, Suite 100 Report Date: April 21, 2008 El Paso, TX 79912 Samples Collected: April 17, 2008 915-833-3740 Date Received: April 18, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Ft. Bliss, Bldg 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-34 5008-0958-01 Off White / Plaster / Fibrous / Homogeneous None Detected Cellulose <1% Binder
S-35 5008-0958-02 Off White / Plaster / Fibrous / Homogeneous None Detected Cellulose <1% Binder
S-36 5008-0958-03 Off White / Plaster / Fibrous / Homogeneous None Detected Cellulose <1% Binder
S-37 5008-0958-04A Off White / Wrap / Fibrous / Homogeneous None Detected Cellulose 95% Binder
5008-0958-04B White / Insulation / Fibrous / Homogeneous
Amosite Chrysotile
15% 20% None Detected Binder
S-38 5008-0958-05A Off White / Wrap / Fibrous / Homogeneous None Detected Cellulose 95% Binder
5008-0958-05B White / Insulation / Fibrous / Homogeneous
Amosite Chrysotile
15% 20% None Detected Binder
S-39 5008-0958-06A Off White / Wrap / Fibrous / Homogeneous None Detected Cellulose 95% Binder
5008-0958-06B White / Insulation / Fibrous / Homogeneous
Amosite Chrysotile
15% 20% None Detected Binder
S-40 5008-0958-07A Off White / Wrap / Fibrous / Homogeneous None Detected Cellulose 80% Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Client:
ENCON International Report Number: 5008-0958 7307 Remcon Circle, Suite 100 Report Date: April 21, 2008 El Paso, TX 79912 Samples Collected: April 17, 2008 915-833-3740 Date Received: April 18, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Ft. Bliss, Bldg 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-40 5008-0958-07B White / Insulation / Fibrous / Homogeneous Chrysotile 35% None Detected Binder
S-41 5008-0958-08A Off White / Wrap / Fibrous / Homogeneous None Detected Cellulose 80% Binder
5008-0958-08B White / Insulation / Fibrous / Homogeneous Chrysotile 35% None Detected Binder
S-42 5008-0958-09A Off White / Wrap / Fibrous / Homogeneous None Detected Cellulose 80% Binder
5008-0958-09B White / Insulation / Fibrous / Homogeneous Chrysotile 20%
10% None Detected Binder
S-43 5008-0958-10A Beige / Wrap / Fibrous / Homogeneous None Detected Cellulose 80% Binder
5008-0958-10B White / Insulation / Fibrous / Homogeneous
Amosite Chrysotile
20% 10% None Detected Binder
S-44 5008-0958-11A Beige / Wrap / Fibrous / Homogeneous None Detected Cellulose 80% Binder
5008-0958-11B White / Insulation / Fibrous / Homogeneous
Amosite Chrysotile
20% 10% None Detected Binder
S-45 5008-0958-12A Beige / Wrap / Fibrous / Homogeneous None Detected Cellulose 80% Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Client:
ENCON International Report Number: 5008-0958 7307 Remcon Circle, Suite 100 Report Date: April 21, 2008 El Paso, TX 79912 Samples Collected: April 17, 2008 915-833-3740 Date Received: April 18, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Ft. Bliss, Bldg 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-45 5008-0958-12B White / Insulation / Fibrous / Homogeneous
Amosite Chrysotile
20% 10% None Detected Binder
S-46 5008-0958-13A Silver,Beige / Wrap / Fibrous / Homogeneous None Detected Cellulose 75% Binder
5008-0958-13B White / Insulation / Fibrous / Homogeneous
Amosite Chrysotile
10% 25% None Detected Binder
S-47 5008-0958-14 White / Insulation / Fibrous / Homogeneous Chrysotile 35% None Detected Binder
S-48 5008-0958-15A Silver,Beige / Wrap / Fibrous / Homogeneous None Detected Cellulose 75% Binder
5008-0958-15B White / Insulation / Fibrous / Homogeneous
Amosite Chrysotile
2% 35% None Detected Binder
S-49 5008-0958-16 White / Window Caulking / NonFibrous / Homogeneous None Detected None Detected Binder
S-50 5008-0958-17 White / Window Caulking / NonFibrous / Homogeneous None Detected None Detected Binder
S-51 5008-0958-18 White / Window Caulking / NonFibrous / Homogeneous None Detected None Detected Binder
S-52 5008-0958-19 White / Door Caulking / NonFibrous / Homogeneous None Detected None Detected Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Client:
ENCON International Report Number: 5008-0958 7307 Remcon Circle, Suite 100 Report Date: April 21, 2008 El Paso, TX 79912 Samples Collected: April 17, 2008 915-833-3740 Date Received: April 18, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Ft. Bliss, Bldg 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-53 5008-0958-20 White / Door Caulking / NonFibrous / Homogeneous None Detected None Detected Binder
S-54 5008-0958-21 White / Door Caulking / NonFibrous / Homogeneous None Detected None Detected Binder
S-55 5008-0958-22 Black,Brown / Material / Fibrous / Homogeneous Chrysotile <1% None Detected Binder
S-56 5008-0958-23 Black,Brown / Material / Fibrous / Homogeneous Chrysotile <1% None Detected Binder
S-57 5008-0958-24 Black,Brown / Material / Fibrous / Homogeneous Chrysotile <1% None Detected Binder
S-58 5008-0958-25A Black / Material / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0958-25B Yellow,Beige / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
S-59 5008-0958-26A Black / Material / NonFibrous / Homogeneous None Detected None Detected Binder
5008-0958-26B Yellow,Beige / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
S-60 5008-0958-27A Black / Material / NonFibrous / Homogeneous None Detected None Detected Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Client:
ENCON International Report Number: 5008-0958 7307 Remcon Circle, Suite 100 Report Date: April 21, 2008 El Paso, TX 79912 Samples Collected: April 17, 2008 915-833-3740 Date Received: April 18, 2008 Contact: David Morales Turn-around time: 24 Hours
Job ID / Site: 103-08-083 (Ft. Bliss, Bldg 112)
Client Sample Number
Lab Sample Number (by layer)
Color / Description / Fibrous / NonFibrous / Homogeneity
Asbestos Content Type & %
Non-Asbestos Fibrous Type & % Matrix
S-60 5008-0958-27B Yellow,Beige / Mastic / NonFibrous / Homogeneous None Detected None Detected Binder
S-61 5008-0958-28 Grey,Black / Material / NonFibrous / Homogeneous None Detected None Detected Binder
S-62 5008-0958-29 Grey,Black / Material / NonFibrous / Homogeneous None Detected None Detected Binder
S-63 5008-0958-30 Grey,Black / Material / NonFibrous / Homogeneous None Detected None Detected Binder
Gary R. Simmons Laboratory Manager
Analytical results and reports are generated by Apex Precision Analytical Services at the request of and for the exclusive use of the person or entity (client) named on such report.
Result, reports or copies of same will not be released by Apex Precision Analytical Services to any third party without the written request from client. These results only repesent the materials submitted. Supporting laboratory documentation is available upon request. This report cannot be used to represent conditions at any other location, date or time and does not imply that this space is free from these or any other contaminants. No responsibility or liability is assumed for the manner in which these results are used or interpreted. This must not be used to claim product endorsement by NVLAP or any government agency of the United States. Apex Precision Analytical Services reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
04/16/2008 1700
Chain of Custody
Relinquished by:__________________________ Received by:_____________________________
Date:_______________Time:_______ Date:_________________Time:_______
Dates Collected: April 16, 2008 Date Sent: April 16, 2008
Contact : David Morales Remarks:
Company: ENCON International P.O. #:
Address: 7307 Remcon Circle, Suite 100
El Paso, TX 79912 APASI#: (For APASI use only)
Phone: (915) 833-3740 Fax: (915) 581-2049
Turn Around Time:
Urgent / ASAP: __ Rush: __ 24 Hr __ 48 Hr Routine: __3 Day __5 Day
Project Name/Number: 103-08-083 (Ft. Bliss, building 112)
Mycology(Mold) Spore Trap-Air Samples
___ Fungal/Mold spore count by Air-O-Cell, Cyclex (d), BioCell, or other spore trap cassette/device
Phase Contrast Microscopy(PCM)-Air Samples ___ Fiber Concentration by NIOSH Method 7400 Issue 2
Industrial Hygiene-Air & Bulk Samples
___ (RCF) Refractory Ceramic Fiber (Bulk) Identification
(Visual Estimation) by Polarized Light Microscopy
Mycology(Mold) Bulk ID Samples
___ Fungal/Mold Identification – bulk sample, tape lift, swab
Polarized Light Microscopy(PLM)-Bulk Samples
____ Asbestos Identification (Visual Estimation) by EPA 600/R-93/116 Method
____ Asbestos Identification (Point Count) by EPA 600/M4-82-020 Method
____ Asbestos Identification (Soil/Prep) by Gravimetric Reduction
Sample #: Location / Description: Volume Instructions
S-01 Cove base mastic
S-02 Cove base mastic
S-03 Cove base mastic
S-04 12” x 12” floor tile/mastic/red flooring
S-05 12” x 12” floor tile/mastic/red flooring
S-06 12” x 12” floor tile/mastic/red flooring
S-07 12” x 12” floor tile/mastic/red flooring
S-08 12” x 12” floor tile/mastic/red flooring
S-09 12” x 12” floor tile/mastic/red flooring
S-10 Textured drywall/joint compound
Sample #: Location: Volume Instructions
S-11 Textured drywall/joint compound
S-12 Textured drywall/joint compound
S-13 Mastic, cove base
S-14 Mastic, cove base
S-15 Mastic, cove base
S-16 Textured plaster
S-17 Textured plaster
S-18 Textured plaster
S-19 2’ x 4’ ceiling panels
S-20 2’ x 4’ ceiling panels
S-21 2’ x 4’ ceiling panels
S-22 Textured drywall/joint compound
S-23 Textured drywall/joint compound
S-24 Textured drywall/joint compound
S-25 Cove base mastic
S-26 Cove base mastic
S-27 Cove base mastic
S-28 12” x 12” floor tile/mastic/red flooring
S-29 12” x 12” floor tile/mastic/red flooring
S-30 12” x 12” floor tile/mastic/red flooring
S-31 Textured plaster
S-32 Textured plaster
S-33 Textured plaster
04/17/2008 1700
Chain of Custody
Relinquished by:__________________________ Received by:_____________________________
Date:_______________Time:_______ Date:_________________Time:_______
Dates Collected: April 17, 2008 Date Sent: April 17, 2008
Contact : David Morales Remarks:
Company: ENCON International P.O. #:
Address: 7307 Remcon Circle, Suite 100
El Paso, TX 79912 APASI#: (For APASI use only)
Phone: (915) 833-3740 Fax: (915) 581-2049
Turn Around Time:
Urgent / ASAP: __ Rush: __ 24 Hr __ 48 Hr Routine: __3 Day __5 Day
Project Name/Number: 103-08-083 (Ft. Bliss, building 112)
Mycology(Mold) Spore Trap-Air Samples
___ Fungal/Mold spore count by Air-O-Cell, Cyclex (d), BioCell, or other spore trap cassette/device
Phase Contrast Microscopy(PCM)-Air Samples ___ Fiber Concentration by NIOSH Method 7400 Issue 2
Industrial Hygiene-Air & Bulk Samples
___ (RCF) Refractory Ceramic Fiber (Bulk) Identification
(Visual Estimation) by Polarized Light Microscopy
Mycology(Mold) Bulk ID Samples
___ Fungal/Mold Identification – bulk sample, tape lift, swab
Polarized Light Microscopy(PLM)-Bulk Samples
____ Asbestos Identification (Visual Estimation) by EPA 600/R-93/116 Method
____ Asbestos Identification (Point Count) by EPA 600/M4-82-020 Method
____ Asbestos Identification (Soil/Prep) by Gravimetric Reduction
Sample #: Location / Description: Volume Instructions
S-34 Textured plaster
S-35 Textured plaster
S-36 Textured plaster
S-37 TSI – 4” pipe insulation
S-38 TSI – 4” pipe insulation
S-39 TSI – 4” pipe insulation
S-40 TSI – 8” pipe insulation
S-41 TSI – 8” pipe insulation
S-42 TSI – 8” pipe insulation
S-43 TSI – 4” pipe elbow insulation
Sample #: Location: Volume Instructions
S-44 TSI – 4” pipe elbow insulation
S-45 TSI – 4” pipe elbow insulation
S-46 TSI – 8” pipe elbow insulation
S-47 TSI – 8” pipe elbow insulation
S-48 TSI – 8” pipe elbow insulation
S-49 Window caulking
S-50 Window caulking
S-51 Window caulking
S-52 Door caulking
S-53 Door caulking
S-54 Door caulking
S-55 Tread texture (stairs)
S-56 Tread texture (stairs)
S-57 Tread texture (stairs)
S-58 Vinyl stair tread mastic
S-59 Vinyl stair tread mastic
S-60 Vinyl stair tread mastic
S-61 Vinyl stair landing tread mastic
S-62 Vinyl stair landing tread mastic
S-63 Vinyl stair landing tread mastic
E N C O N INTERNATIONAL, INC.
LEAD INSPECTION
BUILDING 112
FORT BLISS, TEXAS 79916
Prepared for:
Mr. Henry Wilson, P.E.
DPW
Building 777
Fort Bliss, Texas 79916
Prepared by:
ENCON International, Inc.
7307 Remcon Circle, Suite 103
El Paso, Texas 79912
Date of Inspection:
April 17, 2008
ENCON Project No. 103-08-083
El Paso Office: 7307 Remcon Circle, Suite 103 • El Paso, Texas 79912 Fax 915-581-2049 • Phone 915-833-3740•
E N C O N INTERNATIONAL, INC.
April 18, 2008
Mr. Henry Wilson Phone: (915) 568-2300 General Engineer Via email & hand delivery DPW-Building 777 Fort Bliss, TX 79916
RE: LEAD-BASED PAINT INSPECTION
Building 112
Ft. Bliss, TX 79916
Dear Mr. Wilson:
ENCON International, Inc., (ENCON) has submitted for your review the attached Lead- Based Paint (LBP) Inspection conducted at Building 112, Fort Bliss, Texas. This inspection was performed of the entire building to address the Occupational Safety and Health Administration (OSHA) lead regulations (29 CFR 1926.62).
This LBP Inspection was performed by Mr. Tim Jones, certified Texas Department of State Health Services (DSHS) Lead Risk Assessor on April 16 and 17, 2008 utilizing a NITON XLp 303 AW X-Ray Fluorescence analyzer (XRF) with serial No. 18187.
We appreciate the opportunity to be of service to you. Please call if you have any questions or if we may be of further assistance.
Sincerely, Alex Woelper, P.E.
Project Manager
• Lead Inspection Report
• Lead Drawings
• Technical Documentation
Lead Inspection Report ENCON International. Inc.
Fort Bliss, Building 112 File Number 103-08-083
El Paso Office: 7307 Remcon Circle, Suite 103 • El Paso, Texas 79912 • Fax 915-581-2049 • Phone 915-833-3740
SUMMARY
ENCON International, Inc, (ENCON) presents the findings of the Lead-Based Paint (LBP) Inspection performed at Building 112, Ft. Bliss, Texas 79916. The purpose of this LBP inspection was to determine if LBP was present in the areas scheduled for renovation, and if present, which building components contain LBP. This was determined by performing a surface-by-surface investigation of all painted components. This information is necessary in order for contractors to comply with OSHA regulation 29 CFR 1926.62 Safety and Health Regulations for Construction - Lead.
Lead-based Paint means paint or other surface coatings that contain lead equal to or in excess of 1.0 milligrams per square centimeter (mg/cm2) or more than 0.5%, or 5000 parts per million by weight as established by EPA and HUD regulations. However, for the purposes of this study, ENCON will utilize the “Action Level” of the XRF at 0.3 milligrams per square centimeter (mg/cm2), the NITON XRF detectable limit. Results indicate that seventy-two (72) of the one-hundred-thirty-four (134) XRF readings tested at or above the limit of 0.3 mg/cm2. The LBP Inspection was conducted by Mr.
Tim Jones, a certified Lead Risk Assessor on April 16 and 17, 2008. Results are indicated on a separate drawing and XRF data sheet.
D ESCRIPTION OF AREAS INSPECTED
Building 112 was being used as office space on Fort Bliss, Texas. The building occupied approximately 6,831 SF. The building was a two-story structure constructed with brick walls on a concrete foundation. The building also has a basement that was being used for storage. The interior was partitioned with drywall walls. At the time this Lead Inspection was performed, the date of construction was not known, but it appears that the building has been repainted over the years. The physical condition of the building components and their paints was fair at the time of the inspection. An inventory of the affected painted surfaces was recorded as XRF testing proceeded. See the “LBP Testing Data Sheet.”
CALIBRATION OF THE XRF INSTRUMENT
Before proceeding with the investigation of painted surfaces, the XRF was calibrated in accordance to the manufacturer’s quality control procedures.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .