ROD047279P- Plans and Drawings -22 July 2021 - Building 1558 Emergency Lights W911SG21B0006.pdf
PDF 839 KB Posted
- Attached to
- Bldg. 1558 Emergency Lights & Repairs
- Solicitation number
- W911SG21B0006
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DESIGNED
CHIEF, ENGINEERING DIVISION
DATE
APPROVED
RECOMMENDED
BRANCH CHIEF
SUBMITTED
PROJECT MANAGER
CHECKED
DRAWN BY
NO. DATE
DRAWING NUMBER
SCALE
SHEET OF
SHEET
DESCRIPTION
REVISIONS
APPROVEDBY
SHEET SIZE
ANSI D
DRAWING TITLE
WHITE SANDS MISSILE RANGE, NEW MEXICO
DIRECTORATE OF PUBLIC WORKS
ENGINEERING SERVICES DIVISION
CESAR LIMON
C.LIMON
RAFAEL H. ACOSTA
BUILDING 1558 EMERGENCY LIGHTING
WS-1558-2021-G-G1-01
COVER SHEET / INDEX SHEET
BUILDING 1558
1 04
07/21/20
W H
I T E
S ANDS MIS S I LE
RA
N
G E
B I RTHPLACE
OF
AMERI CA' S MI SSI LE & SPACE
AC
TI
V
IT
Y
CONCURRENCES
Note: Signatures affixed on this sheet indicate official recommendation and approval of all the drawings in this set as indexed on this sheet
Safety
Security
Department
Environmental
Force Protection
Management
Maintenance
Customer 1
Customer 2
DPW
Information
Anti-Terrorism
Fire
Physical
Garrison
Operations &
JIM STEPHENSON
D
E
S
I
G
N
B
I
D
S
E
T
AutoCAD SHX Text
WHITE SANDS MISSILE RANGE, NEW MEXICO
AutoCAD SHX Text
DIRECTORATE OF PUBLIC WORKS
AutoCAD SHX Text
ENGINEERING DIVISION
WATERTOWN AVENUE
S-246
INDIANA STREET
WATERTOWN AVENUE
AUGUSTA STREET
ABERDEEN AVENUE
NIKE AVENUE
WELL #10A
NIKE AVENUE
OW
EN
R
OA
D
SHEET INDEX
DRAWING NUMBER TITLE
WS-1558-2021-G-G1-01 BUILDING 1558 COVER SHEET
WS-1558-2021-G-G1-02 BUILDING 1558 INDEX SHEET/LOCATION
WS-1558-2021-W-FP-03 BUILDING 1558 FLOOR PLAN DIMENSIONS
WS-1558-2021-E-04 BUILDING 1558 ELECTRICAL LAYOUT FOR EMERGENCY
LIGHT INSTALL
DESIGNED
CHIEF, ENGINEERING DIVISION
DATE
APPROVED
RECOMMENDED
BRANCH CHIEF
SUBMITTED
PROJECT MANAGER
CHECKED
DRAWN BY
NO. DATE
DRAWING NUMBER
SCALE
SHEET OF
SHEET
DESCRIPTION
REVISIONS
APPROVEDBY
SHEET SIZE
ANSI D
DRAWING TITLE
WHITE SANDS MISSILE RANGE, NEW MEXICO
DIRECTORATE OF PUBLIC WORKS
ENGINEERING SERVICES DIVISION
CESAR LIMON
C.LIMON
RAFAEL H. ACOSTA
WS-1558-2021-G-G1-02
COVER SHEET / INDEX SHEET
BUILDING 1558
2 04
PROJECT LOCATION BUILDING 1558
LAS CRUCES
GATE
JIM STEPHENSON
D
E
S
I
G
N
B
I
D
S
E
T
07/21/20
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-1437N
AutoCAD SHX Text 1460N
AutoCAD SHX Text 1436N
AutoCAD SHX Text T-1463N
AutoCAD SHX Text S-1649
AutoCAD SHX Text S-1540
AutoCAD SHX Text S-1525
AutoCAD SHX Text
AutoCAD SHX Text S-1690
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-1650
AutoCAD SHX Text S-1523
AutoCAD SHX Text S-1544
AutoCAD SHX Text
AutoCAD SHX Text S-1547
AutoCAD SHX Text S-1546
AutoCAD SHX Text S-1543
AutoCAD SHX Text S-1527
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-1783
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-1790
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-1850
AutoCAD SHX Text
AutoCAD SHX Text S-1735
AutoCAD SHX Text S-1787
AutoCAD SHX Text S-1786
AutoCAD SHX Text
AutoCAD SHX Text S-1852
AutoCAD SHX Text S-1858
AutoCAD SHX Text 1851-N
AutoCAD SHX Text S-1816
AutoCAD SHX Text
AutoCAD SHX Text T-1825
AutoCAD SHX Text T-1817
AutoCAD SHX Text S-1826
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1438N
AutoCAD SHX Text S-1475N
AutoCAD SHX Text S-1472
AutoCAD SHX Text 456N
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-1473N
AutoCAD SHX Text S-1484N
AutoCAD SHX Text
AutoCAD SHX Text B.O.Q.
AutoCAD SHX Text
AutoCAD SHX Text S-1552
AutoCAD SHX Text
AutoCAD SHX Text
FIRE STATION
AutoCAD SHX Text T-145
AutoCAD SHX Text
AutoCAD SHX Text S-1558
AutoCAD SHX Text S-1550
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
EXCHANGE
AutoCAD SHX Text
AutoCAD SHX Text S-421
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-1538
AutoCAD SHX Text S-1524
AutoCAD SHX Text
AutoCAD SHX Text V-2
AutoCAD SHX Text S-122
AutoCAD SHX Text
AutoCAD SHX Text 1867-N
AutoCAD SHX Text 1870-N
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-1781
AutoCAD SHX Text
TANKS
AutoCAD SHX Text S-1799
AutoCAD SHX Text
AutoCAD SHX Text 1866-N
AutoCAD SHX Text 1864-N
AutoCAD SHX Text S-1871
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-1780
AutoCAD SHX Text S-1774
AutoCAD SHX Text
TANKS
AutoCAD SHX Text S-1862
AutoCAD SHX Text S-1860
AutoCAD SHX Text S-1814
AutoCAD SHX Text S-1856
AutoCAD SHX Text S-1810
AutoCAD SHX Text S-1811
AutoCAD SHX Text S-1813
AutoCAD SHX Text S-1854
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WTC
AutoCAD SHX Text
AutoCAD SHX Text
POST DENTAL
AutoCAD SHX Text
HEALTH CLINIC
AutoCAD SHX Text
AutoCAD SHX Text
POST THEATER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
POST OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text T-149
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-305
AutoCAD SHX Text S-302
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text T-383
AutoCAD SHX Text S-375A
AutoCAD SHX Text S-375B
AutoCAD SHX Text S-368
AutoCAD SHX Text S-234
AutoCAD SHX Text
AutoCAD SHX Text S-364
AutoCAD SHX Text
AutoCAD SHX Text S-370
AutoCAD SHX Text T-357
AutoCAD SHX Text S-371
AutoCAD SHX Text S-365
AutoCAD SHX Text S-360
AutoCAD SHX Text S-362
AutoCAD SHX Text S-375D
AutoCAD SHX Text S-375C
AutoCAD SHX Text
AutoCAD SHX Text S-374
AutoCAD SHX Text S-322
AutoCAD SHX Text
DEWEY STREET
AutoCAD SHX Text
PARSONS STREET
AutoCAD SHX Text
BENET STREET
AutoCAD SHX Text
CROZIER STREET
AutoCAD SHX Text
HEADQUARTERS AVENUE
AutoCAD SHX Text
SIOUX STREET
AutoCAD SHX Text
RAMSEY STREET
AutoCAD SHX Text
CRAIG STREET
AutoCAD SHX Text
WATERTOWN AVENUE
AutoCAD SHX Text
HALSEY STREET
AutoCAD SHX Text
BLANDY STREET
AutoCAD SHX Text
NOBLE STREET
AutoCAD SHX Text
HOF STREET
AutoCAD SHX Text
RADFORD STREET
AutoCAD SHX Text
ABERDEEN AVENUE
AutoCAD SHX Text
ABERDEEN AVE
AutoCAD SHX Text
DYER STREET
AutoCAD SHX Text
BENET STREET
AutoCAD SHX Text
CROZIER STREET
AutoCAD SHX Text
DYER STREET
AutoCAD SHX Text
FLAGLER STREET
AutoCAD SHX Text
BENET STREET
AutoCAD SHX Text
WESSON STREET
AutoCAD SHX Text S-1795
AutoCAD SHX Text
RAMSEY STREET
AutoCAD SHX Text
WESSON STREET
AutoCAD SHX Text
JOLIET STREET
AutoCAD SHX Text
HOF STREET
AutoCAD SHX Text
MILAN STREET
AutoCAD SHX Text
ROCK ISLAND AVE
AutoCAD SHX Text
HOF STREET
AutoCAD SHX Text
FRANKFORD STREET
AutoCAD SHX Text
DETROIT STREET
AutoCAD SHX Text
SPRINGFIELD STREET
AutoCAD SHX Text
BENET STREET
AutoCAD SHX Text
ROCK ISLAND AVENUE
AutoCAD SHX Text
WSMR RD. 115
AutoCAD SHX Text
PICATINNY AVE
AutoCAD SHX Text
ZUNI DRIVE
AutoCAD SHX Text
PICATINNY AVENUE
AutoCAD SHX Text
CROZIER STREET
AutoCAD SHX Text
HEADQUARTERS AVENUE
AutoCAD SHX Text
PERSHING DR
AutoCAD SHX Text
ZUNI DR
AutoCAD SHX Text
AutoCAD SHX Text
HUGHES ROAD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MEDICAL
AutoCAD SHX Text S-529
AutoCAD SHX Text
DYER STREET
AutoCAD SHX Text
GATE
AutoCAD SHX Text
GATE
AutoCAD SHX Text
CHAPEL
AutoCAD SHX Text S-1812
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ROCK ISLAND AVENUE
AutoCAD SHX Text S-078B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1538A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HELIPAD
AutoCAD SHX Text
MOUNTAINVIEW
AutoCAD SHX Text
CAFE
AutoCAD SHX Text
POST
AutoCAD SHX Text
HEADQUARTERS
AutoCAD SHX Text
MILITARY PERSONNEL
AutoCAD SHX Text
& ID CARDS
AutoCAD SHX Text
ENGINEERING
AutoCAD SHX Text
ATM
AutoCAD SHX Text
COMMISSARY
AutoCAD SHX Text
BOWLING ALLEY
AutoCAD SHX Text
GYM
AutoCAD SHX Text
GODDARD FIELD
AutoCAD SHX Text
BASEBALL
AutoCAD SHX Text
TENNIS
AutoCAD SHX Text
COURTS
AutoCAD SHX Text
MISSILE PARK
AutoCAD SHX Text
MUSEUM
AutoCAD SHX Text
RANGE CONTROL
AutoCAD SHX Text
J.W. COX
AutoCAD SHX Text
CENTER
AutoCAD SHX Text
WELL #22
AutoCAD SHX Text S-313
AutoCAD SHX Text
HELIPAD
AutoCAD SHX Text
JFK
AutoCAD SHX Text
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
STATION
AutoCAD SHX Text
RECEPTION
AutoCAD SHX Text
CENTER
AutoCAD SHX Text
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
ELECTRONIC
AutoCAD SHX Text
AutoCAD SHX Text
SITE
AutoCAD SHX Text
QUEEN
AutoCAD SHX Text
AutoCAD SHX Text S-1554
AutoCAD SHX Text
AutoCAD SHX Text
NR
AutoCAD SHX Text
STA
AutoCAD SHX Text
CAL
AutoCAD SHX Text
LAB
AutoCAD SHX Text
AutoCAD SHX Text
CLINIC
AutoCAD SHX Text
RECREATION
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text
ISSUE
AutoCAD SHX Text
AutoCAD SHX Text
EXCHANGE
AutoCAD SHX Text
AutoCAD SHX Text T-385
AutoCAD SHX Text
FIELDS
AutoCAD SHX Text
ID & IS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SIERRA
AutoCAD SHX Text
CHAPEL
AutoCAD SHX Text
WSFCU
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text
DEVELOPMENT
AutoCAD SHX Text
CENTER AND LIBRARY
AutoCAD SHX Text
ARTS
AutoCAD SHX Text
AND
AutoCAD SHX Text
CRAFTS
AutoCAD SHX Text
VET
AutoCAD SHX Text
CLINIC
AutoCAD SHX Text
TEMPORARY
AutoCAD SHX Text
LODGING
AutoCAD SHX Text
CYS
AutoCAD SHX Text
REGISTRATION
AutoCAD SHX Text
POOL AND
AutoCAD SHX Text
COMM CTR
AutoCAD SHX Text
MCAFFEE
AutoCAD SHX Text
(PX)
AutoCAD SHX Text
ACS
AutoCAD SHX Text
POLICE
AutoCAD SHX Text
ITALIAN
AutoCAD SHX Text
CAFE
AutoCAD SHX Text
THRIFT
AutoCAD SHX Text
SHOP
AutoCAD SHX Text
CABLE COMPANY
AutoCAD SHX Text
PUBLIC AFFAIRS OFFICE
AutoCAD SHX Text
LAS CRUCES GATE
AutoCAD SHX Text N
AutoCAD SHX Text N
RM 118
260 SF
RM 122
143 SF
RM 121
437 SF RM 124
456 SF
RM 125
214 SF
216 SF
RM 128
243 SF
RM 129
382 SF
RM 127
420 SF
135X
159 SF
RM 130
166 SF
RM 131
167 SF
RM 132
254 SF
RM 133
468 SF
RM 110
1120 SF
RM 112
149 SF
RM 111
72 SF
RM 108
185 SFRM 107
146 SF
RM 109
122 SF
RM 105
363 SF
RM 104
266 SF
RM 102
143 SF
RM 103
142 SF
RM 100
213 SF
RM 101
211 SF
RM 120X
1090 SF
RM 116
351 SF
RM 117
123 SF
RM 119X
123 SF
RM 137X
613SF
Approx. 117'-6"
Approx. 28'-51 4"
Approx. 84'-81 8"
Approx. 212'-4 1 16"
Approx. 29'-65 8"
Approx. 39'-915 16"
DESIGNED
CHIEF, ENGINEERING DIVISION
DATE
APPROVED
RECOMMENDED
BRANCH CHIEF
SUBMITTED
PROJECT MANAGER
CHECKED
DRAWN BY
NO. DATE
DRAWING NUMBER
SCALE
SHEET OF
SHEET
DESCRIPTION
REVISIONS
APPROVEDBY
SHEET SIZE
ANSI D
DRAWING TITLE
WHITE SANDS MISSILE RANGE, NEW MEXICO
DIRECTORATE OF PUBLIC WORKS
ENGINEERING SERVICES DIVISION
CESAR LIMON
C.LIMON
RAFAEL H. ACOSTA
WS-1558-2021-W-FP-03
BUILDING 1558
3 04
FLOOR PLAN
DIMENSIONS
JIM STEPHENSON
D
E
S
I
G
N
B
I
D
S
E
T
1/16" =1' 0"07/21/20
ELECTRICAL LEGEND
EXIT SIGN/EMERGRENCY LIGHT
DISTRIBUTION PANEL
EMERGENCY LIGHTS WALL PACK
RM 118
260 SF
RM 122
143 SF
RM 121
437 SF RM 124
456 SF
RM 125
214 SF
216 SF
RM 128
243 SF
RM 129
382 SF
RM 127
420 SF
135X
159 SF
RM 130
166 SF
RM 131
167 SF
RM 132
254 SF
RM 133
468 SF
RM 110
1120 SF
RM 112
149 SF
RM 111
72 SF
RM 108
185 SFRM 107
146 SF
RM 109
122 SF
RM 105
363 SF
RM 104
266 SF
RM 102
143 SF
RM 103
142 SF
RM 100
213 SF
RM 101
211 SF
RM 120X
1090 SF
RM 116
351 SF
RM 117
123 SF
RM 119X
123 SF
2 2
RM 137X
613SF
N
2" C, 2-#12 AWG,
1-#12 GRD
2" C, 2-#12 AWG,
1-#12 GRD
2" C, 2-#12 AWG,
1-#12 GRD
2" C, 2-#12 AWG,
1-#12 GRD
2" C, 2-#12 AWG,
1-#12 GRD
2" C, 2-#10 AWG,
1-#10 GRD
2" C, 2-#10 AWG,
1-#10 GRD
2" C, 2-#10 AWG,
1-#10 GRD
2" C, 2-#12 AWG,
1-#12 GRD
2" C, 2-#12 AWG,
1-#12 GRD
2" C, 2-#10 AWG,
1-#10 GRD
GRD SIZE OF GROUND WIRE
C CONDUIT
AWG AMERICAN WIRE GAUGE
DESIGNED
CHIEF, ENGINEERING DIVISION
DATE
APPROVED
RECOMMENDED
BRANCH CHIEF
SUBMITTED
PROJECT MANAGER
CHECKED
DRAWN BY
NO. DATE
DRAWING NUMBER
SCALE
SHEET OF
SHEET
DESCRIPTION
REVISIONS
APPROVEDBY
SHEET SIZE
ANSI D
DRAWING TITLE
WHITE SANDS MISSILE RANGE, NEW MEXICO
DIRECTORATE OF PUBLIC WORKS
ENGINEERING SERVICES DIVISION
CESAR LIMON
C.LIMON
RAFAEL H. ACOSTA
WS-1558-2021-E-04
ELECTRI CAL LAYOUT
BUILDING 1558
4 04
FOR EMERGENCY LIGHT
INSTALL
1. THIS PROJECT IS TO BE DONE IN BUILDING 1558. IT IS THE CONTRACTORS SHALL BE RESPONSIBLE TO
PERFORM ABATEMENT AS SPECIFIED IN THE STATEMENT OF WORK.
2. THE CONTRACTOR SHALL KEEP THE WORK AREA CLEAR OF ANY CONSTRUCTION DEBRIS AT ALL
TIMES. ALL DEBRIS GENERATED BY THIS PROJECT SHALL BE PROPERLY DISPOSED OF OFF POST.
CONTRACTOR SHALL COORDINATE WITH THE COR TO INFORM THE BUILDING TENANT TO MOVE ANY
OF THEIR PROPERTY AND HAVE ACCESS TO ALL THE ROOMS WHERE WORK WILL BE PERFORMED
WITHIN 5 DAYS IN ADVANCE FOR WORK BEGIN.
3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND
LOCAL REQUIREMENTS. IN ADDITION ALL WORK MUST COMPLY WITH THE REGULATORY
STANDARDS OF THE NATIONAL FIRE PROTECTION AGENCY, NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION AND THE AMERICAN SOCIETY OF TESTING AND MATERIALS. IT
SHALL ALSO BE ACCOMPLISHED IN ACCORDANCE WITH THE REQUIREMENTS UNDER
NFPA 101 CHAPTER 40 PARAGRAPH 40.2.9 FOR THE EMERGENCY LIGHTING AND THE EXIT SIGNS FALL
UNDER PARAGRAPH 7.10.1.2.1 AND OF THE TECHNICAL REQUIREMENTS OF THE SCOPE OF WORK.
INSTALLATION SHALL COMPLY WITH UFC 3-530-01 SECTION 2-7.1 EMERGENCY LIGHTING, SECTION
2-7.2 EXIT SIGNS, SECTION 2-7.2 EXIT SIGNS, AND SECTION B-7 EMERGENCY AND EXIT LIGHTING AND
NEC 2020 ARTICLES 250, 300.5, 300.10 (E & H), 700.12 (A), 700.15, 700.16, 700.17, AND 700.12.
4. THE LIGHT SWITCH TO EMERGENCY BATTERY BACKUP FIXTURE AND WALL PACK IS A SEPARATE
CIRCUIT. ALL EMERGENCY "EXIT" SIGNS/LIGHT COMBO AND WALL PACKS SHALL BE HARDWIRED. ALL
NEW CONDUIT SHALL BE RIGID AND NEW CONDUCTORS SHALL BE WIRE TYPE THHN, 600 V RATED, AND
COPPER STRANDED FOR ALL EMERGENCY "EXIT" SIGNS/ LIGHT COMBO AND WALL PACKS TO INCLUDE
NEUTRALS, AND GROUNDS. CONDUIT SHALL BE SURFACE MOUNTED OR INSIDE WALLS, ABOVE
CEILING. CONCEAL MOST OF THE EMT AND FLEXIBLE CONDUIT ABOVE AND BELOW CEILINGS
WHEREVER POSSIBLE, CONFINED SPACES AND TIGHTEN ALL CONDUIT SECURE. EXPOSURE OF
CONDUIT IS ALLOWED IN AREAS WHERE IS OPEN CEILING OR CMU WALLS. SEAL ALL PENETRATIONS
AND IF NECESSARY APPLY PAINT AS NEEDED WHERE AREAS ARE SCRATCHED ON THE WALL
RESULTING FROM THE WORK THAT IS BEING PERFORMED.
CONTRACTOR SHALL INSTALL THE EMERGENCY "EXIT" SIGN/LIGHT COMBOS. THIS BUILDING REQUIRES
TO REMOVE THE THREE EXISTING "EXIT" SIGNS AND INSTALL TWELVE EMERGENCY EXIT SIGN/LIGHT
COMBO. THIS BUILDING REQUIRES TO INSTALL TEN (10) EXIT SIGN/LIGHTS TO BE MOUNTED ON THE
WALL WITH THE ARROW POINTING TO THE DOOR, SINGLE FACE, MOUNTED ON THE WALL GRID AND
MONOCHROMATIC LED AND WHITE LED ALONG WITH 90 MINUTES OF BATTERY
LIFE. WHITE HOUSING AND HIGH OUTPUT OF NI CAD BATTERY.
CONTRACTOR SHALL INSTALL WALL PACK EMERGENCY LIGHTS THIS BUILDING REQUIRES
TO INSTALL SIXTEEN (16) WALL PACK LIGHTS MOUNTED ON THE WALL AS SHOWN IN BUILDING LAYOUT.
BASIS FOR THE DESIGN IS A INTEGRATED 2 WHITE LEDS RATED AT 3-WATT AND FOR EACH TO HAVE A
LIFE OF 10 YEARS. A SINGLE FIXTURE TO ILLUMINATE 42 FEET LONG 6 FEET WIDE PATH OF EGRESS AT
ABOUT 12 FOOT MOUNTING HEIGHT ALONG WITH 90 MINUTES OF BATTERY LIFE. HIGH OUTPUT OF NI
CAD BATTERY.
PANEL-3 PHASE, 100 AMP, 208 / 120 V -THERE IS ONE BLANK CIRCUIT TO INSTALL A
AMP
SINGLE POLE TANDEM BREAKER AT SPACE #12 AND CONTRACTOR SHALL RUN A TOTAL OF 140 FEET
OF
" EMT AND 160 FEET OF FLEXIBLE CONDUIT FOR DROP CEILINGS TO INCLUDE #12 WIRE (NEUTRAL
SHALL BE THE SAME SIZE) THHN AND #12 WIRE FOR A GROUND), AND #10 WIRE (NEUTRAL SHALL BE
THE SAME SIZE AND #10 WIRE FOR A GROUND) SHALL BE USED FOR PROVIDING POWER TO THE
EMERGENCY LIGHTING WALL PACKS AND "EXIT" SIGN/ LIGHT COMBOS LOCATED SOUTH
OF THE FACILITY.
PANEL-3 PHASE, 225 AMP, 208 / 120 V -THERE ARE TWO SPARE 20 AMP SINGLE POLE BREAKERS
#31 THRU 33 AND CONTRACTOR SHALL RUN A TOTAL OF 140 FEET OF
" EMT AND 160 FEET OF
FLEXIBLE CONDUIT FOR DROP CEILINGS #12 WIRE (NEUTRAL AND GROUND SHALL BE THE
SAME SIZE) SHALL BE USED FOR PROVIDING POWER TO THE EMERGENCY LIGHTING WALL PACKS AND
"EXIT" SIGN/LIGHT COMBOS LOCATED SOUTH OF THE FACILITY LOCATED NORTH OF FACILITY.
GENERAL NOTES
KEYED NOTES
JIM STEPHENSON
NOTES:
ALL GROUNDS FOR EQUIPMENT, BONDING,
AND NEUTRALS IS SIZED ACCORDING TO
NEC 2020 ARTICLE 250. ALL CONDUIT SHALL BE
METALLIC (EMT AND FLEXIBLE). EMERGENCY LIGHTING
SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE
REQUIREMENTS UNDER NFPA 101 CHAPTER 40
PARAGRAPH 40.2.9 FOR THE EMERGENCY LIGHTING AND
THE EXIT SIGNS FALL UNDER PARAGRAPH 7.10.1.2.1
AND OF THE TECHNICAL REQUIREMENTS OF THE
SCOPE OF WORK.
INSTALLATION
SHALL COMPLY
WITH UFC 3-530-01 SECTION 2-7.1 EMERGENCY
LIGHTING, SECTION 2-7.2 EXIT SIGNS, SECTION 2-7.2
EXIT SIGNS, AND SECTION B-7 EMERGENCY AND
EXIT LIGHTING AND NEC 2020 ARTICLES 210.19 (A),
250, 300.5, 300.10 (E & H), 700.12 (A), 700.15, 700.16, 700.17, AND 700.12. CONDUIT INSTALLATION SHALL
COMPLY WITH UFC 3-520-01 SECTIONS 3-6.2 AND
PANELBOARD SECTIONS 3-2.5.1 AND 3-2.5.2.
D
E
S
I
G
N
B
I
D
S
E
T
1 7/21/2021 ANSWERS RFI QUESTION #1, #2, #4, AND #5 CML
CMLANSWERS RFI QUESTION #3.7/21/20212
07/21/20
| Sheets and Views |
| ROD047279P- Plans and Drawings -21 July 2021 -100% Design Review Building 1558 Emergency Lights Installation-COVER SHEET |
| ROD047279P- Plans and Drawings -21 July 2021 -100% Design Review Building 1558 Emergency Lights Installation-COVER SHEET (2) |
| ROD047279P- Plans and Drawings -21 July 2021 -100% Design Review Building 1558 Emergency Lights Installation-Sheet 2 |
| ROD047279P- Plans and Drawings -21 July 2021 -100% Design Review Building 1558 Emergency Lights Installation-Sheet 2 (2) |
File details come from the government source that posted it. Updated .