Drawings_BLDG_34280_-_W911SG-18-R-0071.pdf

PDF 14 MB Posted

Attached to
BLDG 34280 INTERNAL WATER LINE REPLACEMENT
Solicitation number
W911SG-18-R-0071
Issued by

About this file

Drawings BLDG 34280 - W911SG-18-R-0071

View the file

Other files

File Type Posted
52.218-4201_UXO_POLICY.pdf PDF
SOLICITATION_-_W911SG-18-R-0071.pdf PDF
WSMR_Visitor_Control_Program.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

ENGINEERING SERVICES DIVISION

DIRECTORATE OF PUBLIC WORKS

WHITE SANDS MISSILE RANGE, NEW MEXICO

DESIGN BRANCH

T

CIR

'A

EMA

FO

EC

AL

PH

TR

IB

I H

W

SDNAS

E R

ELISSIM

YTI

V

E G

ITCA

ECAPS&

N A

ELISSIM

SHEET INDEX

DRAWING NUMBER TITLE

WS-34280-2018-G-G1-01 Building 34280 Cover Sheet/Index Sheet

WS-34280-2018-P-P-02 Building 34280 Plumbing Demo Plan

WS-34280-2018-P-P-03 Building 34280 Plumbing Plan

WS-34280-2018-E-E-04 Building 34280 Electrical

DESIGNED

CHIEF, ENGINEERING DIVISION

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

ANSI D

DRAWING TITLE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

RAFAEL ACOSTA

RAFAEL ACOSTA

WILLIAM R. RUCKER

RAFAEL H. ACOSTA

SAMUEL E. MORRIS, JR.

NTS

B34280 REPLACE ALL INTERNAL WATER LINES

WS-34200-2017-G-G1-01

COVER SHEET / INDEX SHEET

BUILDING 34200

ISSUED FOR CONSTRUCTION

MEN'S REST ROOM

WOMEN

ROOM

MECHANICAL

ROOM

CORRIDOR

ENTRY

FOYER

SUPPORT

SUPERVISOR CONFERENCE ROOM

RECEPTIONIST

TELEMETRY LABENTRY

FOYER

BREAK

ROOM

WATER HEATER

4 5

JANITOR

CLOSET

60'-0" 55'-6"

11'-2"

DESIGNED

CHIEF, ENGINEERING DIVISION

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

1/4" =1'

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-34280-2018-P-EP-2

BUILDING 34280

PLUMBING DEMO PLAN

BUILDING 34280 PLUMBING PLAN

GENERAL NOTES

1. REFERENCE LEAD &ASBESTOS SURVEY IN STATEMENT OF WORK FOR IDENTIFIED HAZARDOUS

MATERIAL. IT IS THE CONTRACTORS RESPONIBILITY TO PERFORM ANY ABATEMENT AS SPECIFIED IN

THE STATEMENT OF WORK

KEYED NOTES

DEMO 2" INSULATED COPPER PIPE AND VALVES FROM POINT 4" ABOVE UNDER SLAB ENTRY TO

MECHANICAL NORTH WALL. CAP PIPE AND SEAL CMU OPENING WITH FOAM AND CEMENT FINISH AT

NORTH WALL. LEAVE STUB UP AT SLAB FOR NEW CONNECTION TO NEW WATER LINE.

2 DEMO THREE VERTICAL INSULATED COPPER LINES AND VALVES FROM HORIZONTAL PIPE TO CEILING.

COPPER LINES ARE APPROXIMATELY 1-1/4", 1" AND 12" IN DIA. CAP PIPE AT CEILING, CEILING HEIGHT IS 9

FEET.

3 DEMO VERTICAL AND HORIZONTAL 34" INULATED HOT WATER COPPERLINE ALONG NORTH WALL. CAP PIPE AND SEAL CMU OPENING WITH FOAM AND CEMENT FINISH. CAP PIPE AT CEILING HEIGHT.

4 DEMO 34"HOT AND 1"COLD INSULATED COPPER WATER LINES ABOVE CEILING. HARD CEILING MAY HAVE TO BE REMOVED TO ACCESS PIPING. REPAIR REMOVED CEILING WITH LIKE MATERIALS AND MATCH EXISTING FINISHES. ACCESS TO CEILING SPACE MAY BE ENTERED AT MECHANICAL ROOM.

Rafael Acosta

Rafael Acosta

Bill Rucker

Rafael Acosta

Samuel Morris

65% DESIGN SUBMISSION

65% DESIGN SUBMISSION65% DESIGN SUBMISSIONISSUED FOR CONSTRUCTION

02/06/17 ANSI D

5 DISCONNECT HOT AND COLD WATER PIPING AT PLUMBING FIXTURES AND REMOVE ALL PIPING AND

INSULATION IN CHASE .

2 4

ROOM

MECHANICAL

ROOM

CORRIDOR

ENTRY

FOYER

SUPPORT

SUPERVISOR CONFERENCE ROOM

RECEPTIONIST

TELEMETRY LABENTRY

FOYER

BREAK

ROOM

WATER HEATER

JANITOR

CLOSET

24' - 4" 60'-0" 11'-2"

DESIGNED

CHIEF, ENGINEERING DIVISION

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

1/4" =1'

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-34200-2017-P/A-EP-X

BUILDING 34280

PLUMBING PLAN

BUILDING 34280 PLUMBING PLAN

GENERAL NOTES

1. REFERENCE LEAD &ASBESTOS SURVEY IN STATEMENT OF WORK FOR IDENTIFIED HAZARDOUS

MATERIAL. IT IS THE CONTRACTORS RESPONIBILITY TO PERFORM ABATEMENT AS SPECIFIED IN THE

STATEMENT OF WORK.

KEYED NOTES

INSTALL NEW 1-1/2" COPPER LINE RISER WHERE EXISTING PIPE WAS DEMOLISHED. INSTALL

REGULATING VALVE AT 1 FOOT HEIGHT WITH INLET AND OUTLET PRESSURE GAUGES. INSTALL 1-1/2"

COPPER LINE FROM RISER TO NORTH WALL AT SAME PREVIOUS HEIGHT BELOW ELECTRICAL.

SUPPORT RISER AND VALVE TO SLAB OR WALL. RECONNECT ELECTRICAL GROUNDING TO COPPER

PIPE. INSULATE WATER LINE WITH 1" FLEXIBLE ELASTOMERIC INSULATION.

INSTALL NEW TEE CONNECTION WITH 1" PEX PIPE AND LEVER BRASS BALL VALVE, CONNECTED TO EXISTING WATER HEATER. INSTALL 1" PEX PIPE TO CEILING HEIGHT AND TOP OF CHASE. ANCHOR

PIPING TO CMU WALL. INSULATE WATER LINE WITH 1" FLEXIBLE ELASTOMERIC INSULATION.

INSTALL NEW 1" PEX PIPE WITH LEVER BRASS VALVE UP TO CEILING HEIGHT AND TOP OF CHASE.

ANCHOR PIPING TO CMU WALL INSULATE WATER LINE WITH 1" FLEXIBLE ELASTOMERIC INSULATION.

INSTALL NEW 1" COLD AND HOT PEX WATER LINE TO PLUMBING FIXTURES ABOVE CHASE. DROP 12"

COLD AND HOT PEX WATER LINES TO FIXTURES AND CONNECT TO EXISTING VALVES AT EACH

PLUMBING FIXTURE. INSULATE WATER LINE WITH 1" FLEXIBLE ELASTOMERIC INSULATION.

DEMOLITION OF HARD CEILING MAY BE REQUIRED TO COMPLETE WORK. ANY CEILING REMOVED

SHALL BE REPLACED WITH LIKE MATERIALS AND FINISHES.

5 INSTALL NEW INSTANTANEOUS WATER HEATER UNDER THE LAVATORY MODEL CHRONOMITE

SR-20L/208. INSTALLATION SHALL BE PER MANUFACTURERS INSTRUCTIONS. SEE ELECTRICAL

DRAWING FOR ELECTRICAL REQUIREMENTS.

6 INSTALL NEW WATER HAMMER ARRESTERS (SIOUX CHIEF 653B) ON HOT AND COLD WATER LINES ABOVE CEILING. INSTALL ACCESS PANEL 18" X 18" METAL (ACUDOR) IN JANITOR CLOSET CEILING..

Rafael Acosta

Rafael Acosta

Bill Rucker

Rafael Acosta

Samuel Morris

65% DESIGN SUBMISSION

65% DESIGN SUBMISSION65% DESIGN SUBMISSIONISSUED FOR CONSTRUCTION

02/06/17 ANSI D

2. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH IPC. ALL EXTERIOR COPPER PIPE AND RISER INTO BUILDING SHALL BE TYPE K, ALL INTERIOR PIPE 1" BELOW TO BE PEX CONFORMING TO ASTM F 877. PEX FITTINGS SHALL MEET ASTM F 1807, METAL-INSERT TYPE COPPER OR STAINLESS-STEELCRIMP RINGS AND MATCHING PEX TUBE DIMENSIONS. HYDROSTATIC TEST ALL NEW

PIPING TO 1-1/2 TIMES THE OPERATING PRESSURE FOR NOT LESS THAN 1 HOUR.

3 4

ROOM

MECHANICAL

ROOM

CORRIDOR

ENTRY

FOYER

SUPPORT

SUPERVISOR CONFERENCE ROOM

RECEPTIONIST

TELEMETRY LABENTRY

FOYER

BREAK

ROOM

INSTANTANEOUS

WATER HEATER

JANITOR

CLOSET

30 AMP DISCONNECT

SWITCH

CONDUIT

"WALL

MOUNTED"

J BOX

DESIGNED

CHIEF, ENGINEERING DIVISION

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

1/4" =1'

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-34200-2017-EP-EP-4

BUILDING 34280

ELECTRICAL PLAN

BUILDING 34280 ELECTRICAL PLAN

GENERAL NOTES

1. REFERENCE LEAD &ASBESTOS SURVEY IN STATEMENT OF WORK FOR IDENTIFIED HAZARDOUS

MATERIAL. IT IS THE CONTRACTORS RESPONIBILITY TO PERFORM ABATEMENT AS SPECIFIED IN THE

STATEMENT OF WORK.

KEYED NOTES

ELECTRICAL REQUIREMENTS FOR LAVATORY MODEL CHRONOMITE SR-20L/208 AS SPECIFIED BY

MANUFACTURE'S INSTALLATION MANUAL.

1A) 2 CONDUCTORS (RED AND BLACK) -#12 AWG THHN, 600 V RATED, 30 AMP, COPPER, STRANDED, AND

90 DEG C

(CONDUCTOR IS SIZED AT 125% OF THE WATER HEATER RATING)

1B) DOUBLE POLE 30 AMP BREAKER TO BE RETROFITTED IN EXISTING DISTRIBUTION PANEL

(OVERCURRENT PROTECTION DEVICE SIZED NO MORE THAN 150% OF APPLIANCE

RATING)

1C) EQUIPMENT GROUND: 1 CONDUCTOR (GREEN)-#10 AWG THHN, 600 V RATED, COPPER, STRANDED, AND 90 DEG C

1D) RIGID GALVANIZED CONDUIT 1/2 INCH WITH JBOX

1E) TERMINATE CONDUCTORS TO EXISTING THREE PHASE DISTRIBUTION PANEL.

1D) 2 POLE HEAVY DUTY FUSE DISCONNECT SWITCH, 30 AMPS, 240 VOLTS, AND NEMA 3R.

Cesar Limon

Cesar Limon

Bill Rucker

Rafael Acosta

Samuel Morris

65% DESIGN SUBMISSION

65% DESIGN SUBMISSION65% DESIGN SUBMISSION

ISSUED FOR CONSTRUCTION

02/06/17 ANSI D

2. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH IPC. ALL EXTERIOR COPPER PIPE AND RISER INTO BUILDING SHALL BE TYPE K, ALL INTERIOR PIPE 1" BELOW TO BE PEX CONFORMING TO ASTM F 877. PEX FITTINGS SHALL MEET ASTM F 1807, METAL-INSERT TYPE COPPER OR STAINLESS-STEELCRIMP RINGS AND MATCHING PEX TUBE DIMENSIONS. HYDROSTATIC TEST ALL NEW

PIPING TO 1-1/2 TIMES THE OPERATING PRESSURE FOR NOT LESS THAN 1 HOUR.

EXISTING 208 / 120 V, THREE PHASE PANEL, AND WIRE TROUGH.

3. CONDUIT:

A) FITTINGS REQUIRED TO COMPLETE ELECTRICAL CONDUIT SYSTEMS. INCLUDES CAPS, CONNECTORS, COUPLINGS

(EXCLUDING EXPANSION AND EXPANSION-DEFLECTION COUPLINGS), NIPPLES, REDUCERS, ELBOWS, PIPE, PLUGS LOCKNUTS, BOND NUTS, BUSHINGS, SEALS (EXCLUDING WALL PENETRATION AND ANY OTHER FITTINGS.)

B) DEVICES REQUIRED TO COMPLETE ELECTRICAL CONDUIT SYSTEMS AND TO FASTEN, CLAMP, ATTACH, AND

SUPPORT EACH CONDUIT IN PLACE.

1) INCLUDES THREADED JOINT COMPOUND; PROTECTIVE SEALANT; MATERIALS FOR SEALING ENDS OF CONDUITS

TERMINATING AT OUTDOOR BOXES, PANEL BOARDS OR CABINETS; SUPPORTS AND CLAMPS.

2) COMPLETE WITH BOLTS, WASHERS, AND NUTS.

A) JUNCTION BOX, JUNCTION BOX EXTENSIONS, AND JUNCTION BOX COVERS: STEEL, OR ZINC COATED.

B) EXPANSION COUPLINGS:

1) FURNISH FOR LONGITUDINAL MOVEMENT ONLY.

4. ALL ELECTRICAL CONNECTIONS MUST BE PROPERLY TORQUED TO PREVENT EXCESSIVE HEAT BUILDUP CAUSED BY A LOOSE CONNECTION OR DAMAGE OF THE CONDUCTOR All CAUSED BY OVERHEATING. TOO LOOSE A CONNECTION OR TOO TIGHT A CONNECTION CAN CAUSE PROBLEMS. CIRCUIT BREAKER TERMINALS DIFFER FROM SWITCH AND AND RECEPTACLE TERMINALS IN

TIGHTENING WITH PROPER TORQUE.

a) TERMINAL CONNECTORS:

1. HEAVY-DUTY, PRE INSULATED, PRESSURE-CRIMP TYPE WITH RING TONGUES.

2. TIN-PLATED COPPER.

3. SERRATED INNER BARREL.

4. 600-VOLT-RATED VOLT-RATED NYLON INSULATION.

5. INSULATION SUPPORT SLEEVE FOR VIBRATION RESISTANCE.

6. UL LISTED.

7. COMPATIBLE WITH CONDUCTOR SIZE AND TYPE OF CABLE FOR WHICH IT

USED.

5. MODEL SR-20L/208 SINGLE PHASE ELECTRICAL SPECS:

VOLTAGE: 208 V

WATTS: 4160 W

AMPERAGE CAPACITY: 20 A

6. CONTRACTOR SHALL INSTALL ALL ELECTRICAL EQUIPMENT TO FOLLOW THE NEC 2017.

7. DRILL HOLES AS NEEDED IN CONCRETE FOR INSTALLATION OF CONDUIT THRU WALLS. GROUT

CONDUIT IN PLACE IN ACCORDANCE NO SHRINK GROUT. CONTRACTOR SHALL

SUBMIT APPROVAL DATA (MANUFACTURER'S PRODUCT DATA) AND INSTRUCTIONS

(MANUFACTURER'S SURFACE PREPARATION, MIXING, INSTALLATION, AND CURING INSTRUCTIONS).

8. CONDUIT WALL/FLOOR PENETRATION SEALS:

-ELASTOMERIC MATERIAL TO PREVENT LIQUID OR LIQUID AND GAS SEEPAGE.

-DUST TIGHT.

-FIRE RETARDANT.

REMOVE BURRS AND SHARP CORNERS AT ENDS OF METAL CONDUIT.

4 4

Sheets and Views
34280RA-COVER SHEET
34280RA-PLUMBING DEMO PLAN
34280RA-PLUMBING PLAN)