This document is a Specification Sheet for a 20' Portable Shipping Container Office. The key details are:
The office container specifications include:
- 20'(L) x 8'(W) x 8'6"(H) new or one-trip standard container, primed and painted exterior
- 2"x4" wood stud framing on 16" centers with R-13 batt insulation and drywall or whiteboard interior walls
- 125-amp 12 slot electrical panel with 60A exterior disconnect, 2 LED interior lights, 5 floor outlets, 2 desk-height outlets, and 4 data pass-throughs
- 36" exterior weather-tight man door, 2 explosion/hurricane-proof 3'x3' windows
- 18,000 BTU PTAC unit or wall-mount HVAC with electric resistance heating
- Epoxy or vinyl flooring
This specification sheet is related to Solicitation W911S6-24-Q-0017 for the Dugway Proving Grounds (DPG) West Desert Test Center (WDTC) Chemical Test Division (CTD) to purchase 1 unit of this 20' portable office container.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| TSD Drawings Operations Trailer 230810.pdf | ||
| RFQ Operations Trailer Dugway 06-05-2024.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
20’ Portable Shipping Container Office
Specification Sheet
Exterior -1 – 20’(L) x 8’(W) x 8’6”(H) NEW (preferably) Standard Container or Undamaged One-Trip Standard Container -Exterior Primed and Painted w/ durable Exterior Paint (Light Colored Beige or Light Tan) Framing and Walls -2” x 4“ Wood Stud framing on 16” centers -R-13 Batt Wall and Ceiling Insulation -½” Drywall or Whiteboard Paneling Electrical and Lighting -1 – 125-amp 12 slot Electrical Panel w/ 60A Exterior Disconnect (If outdoor must be rain tight) -2 – Low profile 2 Lamp 4’ LED interior lights w/ Dimmer switch -1 – Outdoor exterior LED flood light (must be rain tight) -5 – Floor level 110V Duplex Outlets -2 – Desk Height 110V 2 Gang Duplex Outlets (above Desktop) -4 – Sealable Data Pass-throughs (Below Desktop Height) Interior -1 – 24”(D) Full length Desk Top @30”(H) Flooring -Epoxy or Vinyl Flooring Doors and Windows -1 – 36” Exterior Weather Tight Man Door -2 – 3’ x 3’ Windows (Explosion or Hurricane Proof)
HVAC
-1 – 18,000 BTU PTAC Unit w/ Electric Resistance Heating or 18,000 BTU BARD Wall Mount Unit w/ Electric Resistance Heating