This document is a Specification Sheet for a 20' Portable Shipping Container Office. The key details are:

The office container specifications include:

  • 20'(L) x 8'(W) x 8'6"(H) new or one-trip standard container, primed and painted exterior
  • 2"x4" wood stud framing on 16" centers with R-13 batt insulation and drywall or whiteboard interior walls
  • 125-amp 12 slot electrical panel with 60A exterior disconnect, 2 LED interior lights, 5 floor outlets, 2 desk-height outlets, and 4 data pass-throughs
  • 36" exterior weather-tight man door, 2 explosion/hurricane-proof 3'x3' windows
  • 18,000 BTU PTAC unit or wall-mount HVAC with electric resistance heating
  • Epoxy or vinyl flooring

This specification sheet is related to Solicitation W911S6-24-Q-0017 for the Dugway Proving Grounds (DPG) West Desert Test Center (WDTC) Chemical Test Division (CTD) to purchase 1 unit of this 20' portable office container.

View the file

Other files

File Type Posted
TSD Drawings Operations Trailer 230810.pdf PDF
RFQ Operations Trailer Dugway 06-05-2024.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

20’ Portable Shipping Container Office

Specification Sheet

Exterior -1 – 20’(L) x 8’(W) x 8’6”(H) NEW (preferably) Standard Container or Undamaged One-Trip Standard Container -Exterior Primed and Painted w/ durable Exterior Paint (Light Colored Beige or Light Tan) Framing and Walls -2” x 4“ Wood Stud framing on 16” centers -R-13 Batt Wall and Ceiling Insulation -½” Drywall or Whiteboard Paneling Electrical and Lighting -1 – 125-amp 12 slot Electrical Panel w/ 60A Exterior Disconnect (If outdoor must be rain tight) -2 – Low profile 2 Lamp 4’ LED interior lights w/ Dimmer switch -1 – Outdoor exterior LED flood light (must be rain tight) -5 – Floor level 110V Duplex Outlets -2 – Desk Height 110V 2 Gang Duplex Outlets (above Desktop) -4 – Sealable Data Pass-throughs (Below Desktop Height) Interior -1 – 24”(D) Full length Desk Top @30”(H) Flooring -Epoxy or Vinyl Flooring Doors and Windows -1 – 36” Exterior Weather Tight Man Door -2 – 3’ x 3’ Windows (Explosion or Hurricane Proof)

HVAC

-1 – 18,000 BTU PTAC Unit w/ Electric Resistance Heating or 18,000 BTU BARD Wall Mount Unit w/ Electric Resistance Heating

File details come from the government source that posted it. Updated .