A02_-_Salient_Characteristics.doc

DOC document 44 KB Posted

Attached to
One (1) unit Aerosol jet machine system
Solicitation number
W911QX-19-R-0042
Issued by

About this file

Salient Characteristics document

View the file

Other files

File Type Posted
A02_-_Sources_Sought.doc DOC document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics

Commercial Availability Certification:

I have evaluated the commercial marketplace and determined that all of the salient characteristics documented below are available in products/services offered in the commercial marketplace.

Signature (typed name): Jian H. Yu Technical Point of Contact (TPOC) or Contracting Officer’s Representative (COR)

The Contractor shall provide one (1) unit Aerosol jet machine system with the following specifications.

Salient Characteristics:

1) The aerosol jet machine system shall be capable of printing aerosol of any fluidized nano-particulate material, such as metal, ceramic, and plastic onto a substrates.

2) The aerosol jet machine system shall be able to print at least twenty (20) microns conducting traces of silver, gold, and copper.

3) The aerosol jet machine system shall be able to accept a trunnion to print on a work piece’s surface. Upgradable to five (5)-axis operation.

4) The aerosol jet machine system shall be able to print on three-dimensional (3-D) surface conformably.

5) The aerosol jet machine system shall come equipped with build chamber to accommodate 3-D printing volume of at least 20 centimeter x 20 centimeter x 20 centimeter.

6) The aerosol jet machine system shall come equipped with a built-in controller and program to prepare geometry files to print; accept G-code (also known as RS-27), which is the common name for the most widely used numerical control (NC) programming language for machining path.

7) The aerosol jet machine system shall be capable of operating using 100–120 voltage alternate current (VAC), and shall have electrical connection for 120 VAC, 60Hz, 40amps, Single Phase.

8) The Contractor shall provide shipping, installation, and training on how to operate the system at Aberdeen Proving Ground, Maryland.

9) The Contractor shall provide a three (3) year warranty, an on site Preventive Maintenance (PM), machine updates, and remote assistance.

Contracting Officer:

Template last updated 07/28/2016