Salient Characteristics
One (1) Photovoltaic (PV) Simulator that meets government’s requirements listed below:
· The photovoltaic array simulator shall have ability to approximate a photovoltaic array with a minimum of 256 points of resolution
· The photovoltaic array simulator shall have the ability to rate for output isolation from alternating current (AC) input of a minimum of plus/minus (+/-) 600 volts direct current (VDC).
· The photovoltaic array simulator shall have an ethernet-based communication system.
· A tracking speed of 10 milliseconds (ms), equivalent to a bandwidth of 100 hertz (Hz), is required for the simulator output response