Bldg._125_Floor_plan.pdf
PDF 50 KB Posted
- Attached to
- INSTALL COMPRESSED AIR LINES AT B-125 Federal contract opportunity
- Solicitation number
- W911PT-19-Q-0042
About this file
FLOOR PLAN
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SITEVISIT.doc | DOC document | |
| Bldg._125_ICW_Marked_Up.2.pdf | ||
| 8PW127_SOW._rev2.docx | DOCX document | |
| 03_01_00_-_CONCRETE_(Slabs,_Pads,_Small_Jobs).doc | DOC document | |
| Compressed_Air_Bldg._125.png | PNG image | |
| W911PT-19-Q-0042.pdf | ||
| 23_05_15_-_COMMON_PIPING_FOR_HVAC_(Steam,_Condensate,_Copper).doc | DOC document | |
| 05_05_33_-_Anchor_Systems.doc | DOC document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C B A
B A
E
C D
G F
H I
14 15139 10 12117 8654321
6 7 8 9 10 11
A
B
C
D
E
H
I
G
F
2177 SF
SHIPPING
123 SF
ELECTRICAL
ROOM
137 SF
OFFICE
137 SF
OFFICE
137 SF
OFFICE
137 SF
OFFICE
446 SF
OPEN OFFICE
292 SF
CONFERENCE
ROOM
24916 SF
PRODUCTION
ROOM
932 SF
INSPECTION
1A
1B
107A
8A
318 SF
COMPRESSOR
ROOM
A-301
36' - 1 3/4"
PROVIDE 16' W X 12'H WALL
OPENING WITHIN EXISTING WALL
ASSEMBLY
ALIGN
1' - 0"
10' - 0" 10' - 0" 10' - 0" 10' - 0" 14' - 0" 3' - 4 1/8"
1&3
12M2
6A6A
6A6A 6A
6A
6M
6A 6A
ALIGN
6A
6A
6A
6A
REMOVE EXISTING WINDOW ASSEMBLY AT THIS LOCATION INCLUSIVE OF THE EXISTING EXTERIOR
MASONRY AND ITS CONCRETE WINDOW SILL BELOW EXISTING WINDOW ASSEMBLY. REPAIR
OPENING AND INSTALL OVERHEAD COILING DOOR ASSEMBLY. OVERHEAD COILING DOOR SHALL BE
EXTERIOR MOUNT AND SECURED TO STRUCTURE AS PER STRUCTURAL DRAWINGS.
266 SF
OFFICE
CORRIDOR
EXISTING CORRIDOR (NOT IN CONTRACT)
12M212M212M2
1820 SF
CAGED AREA
EXISTING TENANT (NOT IN CONTRACT)
EXISTING TENANT (NOT IN CONTRACT)
EXISTING TENANT (NOT IN CONTRACT)
1'
0"
EXISTING VESTIBULE
(NOT IN CONTRACT)
6"
A-801
A-801
A-801
A-801
M + W GROUP
KEY PLAN
CLIENT PROJECT
SHEET TITLE
SOFTWARE
DATE
DRAWN
CHECKED
ISSUED/APPROVE
SCALE/SHT. SIZE
NAME PROJ. NO.
SHEET NO.
REV.
M W
Z a n d e r.
A ll ri g h ts re se rv e d
R e p ro d u c ti o n in w h o le o r in p a rt is p ro h ib it e d w it h o u t th e w ri tt e n c o n se n t o f th e c o p yr ig h t o w n e r.
C
CONSULTANT
F1 (30X42) Revit
M+W U.S., Inc.
Fax: (518) 266-3458 Telephone: (518) 266-3400
44 Dalliba Avenue Watervliet, NY 12189
CLEVELAND POLER TECHNOLOGIES
1/8" = 1'-0"
C :\U se rd at a\ rm el ah n\
D es kt op
\C
PT
\C
PT
-A -C
EN
-R
M .rv t
8/
/2
:3 8:
A
M
A-201
15211R. FLOGE
J. JEHRING
ARCHITECTURAL FLOOR PLAN
7-10-2012 7/10/2012
RF JJ
RF JJA 7/10/2012 SCHEMATIC DESIGN
B 7/31/2012 DETAILED DESIGN
C
KEY PLAN
PLAN NORTH
REV DATE DESCRIPTION DRAWN CHECKED
File details come from the government source that posted it.