This document is a Salient Characteristics specification for a Cable Conduit (P/N: 13645752-001) required by the government. The cable conduit must conform to an accompanying drawing and be compatible with connector D38999/26KJ4SN, with connector interface per SAE AS80549 Figure 4 and shell size 36. The connector adapter shall be electrically bonded to the conduit, with O-Ring material specified as EPDM and jacket material as EPDM or high-performance silicone elastomer per Glenair Duralectric Technical specifications. The conduit assembly shall be constructed per A-A-52440 Type I grade B with brass convoluted tube covered with bronze braid and outer jacket.
Material and plating requirements vary by production lot. For P1, adapters, ferrules, and coupling nuts shall be 6061-T6 aluminum alloy with electroless nickel plating per AMS-C-26074 grade B class 4, followed by cadmium plating per AMS-QQ-P-416 type II class 2 with olive drab chromate passivation. For P2 and P3, these components shall be stainless steel passivated per SAE-AMS2700 method I, class 2, type 6. An optional anti-decoupling device (self-locking feature) is required for all threaded joints, with lockwires and set screws prohibited. The contractor must use standard commercial preservation and packaging methods appropriate for the equipment and acceptable to commercial carriers, ensuring delivery to LEAD in good condition. All equipment shall be inspected and accepted based on compliance with design, functionality, construction, materials, components, and workmanship requirements, with any deviations subject to rejection.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Combined Synopsis Soli W911N226QA054_KO Approved.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS
CABLE CONDUIT (P/N: 13645752-001)
1. GOVERNMENT NEEDS: A Cable Conduit that conforms to the drawing.
2. SPECIFICATIONS: End fitting shall be compatible with connector D38999/26KJ4SN.
Connector interface shall be in accordance with SAE AS80549 Figure 4. Shell size 36.
Connector adapter shall be electrically bonded to conduit. O-Ring material shall be EPDM.
Jacket material shall be EPDM or high-performance silicone elastomer in accordance with Glenair Duralectric Technical spec. Conduit assembly shall be constructed per A-A-52440 Type I grade B with brass convoluted tube covered with bronze braid with an outer jacket.
For P1: Adapters, ferrules, and coupling nuts shall be 6061-T6 aluminum alloy plated with electroless nickel in accordance with AMS-C-26074 grade B class 4 followed by cadmium plating in accordance with AMS-QQ-P-416 type II class 2 with chromic acid passivation using olive drab chromate. Finished items shall meet the workmanship requirements of AMS-QQ-P- 416.
For P2 & P3: Adapters, ferrules, and coupling nuts shall be stainless steel passivated in accordance with SAE-AMS2700 method I, class 2, type 6. Finished items shall meet the surface appearance requirements of SAW-AMS2700. Conduit assembly shall include mechanical features to electrically terminate internal shields to connector adapter by utilizing the banding system. Shield termination feature shall allow assembly and disassembly without damaging internal shield braid.
3. Options: All threaded joints shall have an anti-decoupling device (Self-locking feature).
Lockwires or set screws shall not be used for this purpose.
4. PRESERVATION, PACKAGING AND DELIVERY: The contractor shall utilize standard commercial methods for preservation and packaging appropriate for the provided equipment and acceptable to commercial carriers. As a minimum, all areas susceptible to damage from exposure to the elements shall be preserved and/or packed to prevent damage. The contractor shall be responsible for ensuring the equipment is delivered to LEAD in good condition.
5. INSPECTION AND ACCEPTANCE: The equipment provided shall be examined for design, functionality, construction, materials, components, and workmanship to determine compliance with the contract and this specification. Any deviation from these requirements shall be cause for rejection.