Rain_Test_Recirc_Project_Attachment_B.pdf

PDF 15 KB Posted

Attached to
WATER RECIRCULATION UPGRADE FOR THE TRUCK WASH RAIN TEST SYSTEM
Solicitation number
W911N2-18-Q-0025
Issued by

About this file

Rain Test Recirculation Project Drawing B

View the file

Other files

File Type Posted
SOL_AMEND_W911N218Q00250005.pdf PDF
Pictures.pdf PDF
SOL_Amend_W911N218Q00240004.pdf PDF
SOL_AMEND_W911N218Q00250003.pdf PDF
SOL_AMEND_W911N2-18-Q-0025-0002.pdf PDF
DSC01012.jpg JPG image
DSC01014.jpg JPG image
DSC01013.jpg JPG image
DSC01015.jpg JPG image
SOL_AMEND_W911N2-18-Q-0025-0001.pdf PDF
North_Wash_Bay.jpg JPG image
Equip_Room_North.jpg JPG image
Equip_Room_South.jpg JPG image
South_Wash_Bay.jpg JPG image
Equip_Room_North_Closeup.jpg JPG image
Wash_Bay_Sump_Pit_Area.jpg JPG image
Equip_Room_South_Closeup.jpg JPG image
PD_W911N218Q0025.pdf PDF
SOL_W911N218Q0025.pdf PDF
Rain_Test_Recirc_Proj_-_Attchmt_A.pdf PDF
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Holding Tank

Rain Test

Reclaim Tank 850

Gallons

(Supplied by

Letterkenny)

Collection

Trench

Control Panel & Pumps

Rain Test Reclaim

Skid- Pump, Bag

Filter Controls

Gantry Wash

Rain Test Recirculation Project

Bulk Head Inlet Festoon Hoses

Feed Gantry Wash System

Gantry Rails

RSP

Fresh Water

Makeup

1. Rain Test is fed by rinse pump to Gantry wash unit.

2. Water from the test accumulates in the wash bay trench.

3. A manual controlled ball valve is closed using a T-Bar.

4. Water from the trench is diverted to the rain test sump pit.

5. The rain test sump pump will pump water from the sump thorough the bag filter and into the 850 gallon rinse water reclaim tank. Oxygen will be added on a continuous basis to the rain test reclaim tank.

6. The reclaim tank will feed to the rinse water pump on the pump skid.

7. A fresh water makeup line will feed the loop as necessary based on a 20 gallons/minute max flow rate from the rinse pump.

7. Controls will keep the pumps working to recirculate water in the loop as long as the rain test is in operation.

**8. Float control valves in the sump pit and the rain test reclaim tank will be utilized to balance incoming and outgoing flow for the loop.

Bag Filter

Rinse Pump

Sump Pump

Gantry Rails

Gantry Path

Gantry Path Gantry Path

Gantry Path

Attachment B

5-17-2018

O2

Generator

Spray

Nozzles

Spray

Nozzles

Concrete sump is supplied by

Letterkenny

Rain Test

Sump

**8

**8

Rain Test Recirc Project Attachment B.vsd
Page-1