This amendment modifies the solicitation for the FTW439 Child Development Center project. The solicitation is a two-phase design-build opportunity issued by the Department of the Army Corps of Engineers Engineering District Alaska to construct a child development center at Fort Wainwright, AK.

The amendment increases the number of design firm projects offerors can submit from five to eight total, with no more than three projects per individual design firm. Specialties include civil, architectural, structural, mechanical, electrical, telecommunications, playgrounds and fire protection design. The proposal due date is not extended. Offerors must acknowledge receipt of the amendment by completing items on the reverse side of the solicitation form or with a separate letter.

View the file

Other files

File Type Posted
W911KB21R0005 FTW439 JA Redacted.pdf PDF
FTW439 Phase 1 RFP FINAL.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FTW439

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

PROJECT TITLE/LOCATION: FTW439 DESIGN-BUILD CHILD DEVELOPMENT CENTER, FORT WAINWRIGHT, ALASKA

a. This amendment provides changes to the solicitation as indicated on the continuation pages of this document.

b. PROPOSAL DUE DATE HAS NOT BEEN EXTENDED.

c. YOU ARE REQUIRED TO ACKNOWLEDGE RECEIPT OF THIS AMENDMENT ON THE REVERSE SIDE OF THE RFP STANDARD FORM 1442.

1. CONTRACT ID CODE PAGE OF PAGES

1 4

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 28-Apr-2021

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W911KB21R0005

X 9B. DATED (SEE ITEM 11)

07-Apr-2021

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

28-Apr-2021

CODE

U.S. ARMY ENGINEER DISTRICT, AK

CEPOA-CT (W911KB)

PO BOX 6898

JBER AK 99506-0898

W911KB 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W911KB21R0005

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

a. The following drawings are substituted for the superseded documents/sections: NONE

b. The following revised documents/sections are substituted for the superseded documents/sections: The identifier “AM#0001” appears before and after new and/or revised materials, except as noted below.

Section 00 22 10 - PHASE 1 OF 2 PHASE DESIGN-BUILD SELECTION PROCEDURES --Revised paragraph 5.1 (Reissuing page 3 of section)

NOTE: Revisions within the following documents do not contain the above referenced identifiers:

c. The following sections are deleted: NONE

d. The following documents are added: Phase I Bid Inquiry Contractor Report

e. The following revisions are incorporated: NONE

f. Other: NONE

ALL OTHER TERMS AND CONDITIONS SHALL REMAIN THE SAME.

(End of Summary of Changes)

Section 00 22 10 W911KB21R0005

FTW439

Section 00 22 10 Page 3

Location Factor Number Description Relative Importance

Tab D Factor 3 Organization & Management 3rd Most Important Factor (slightly less important than Factors 1 and 2 and more important than Factor 4)

Tab E Factor 4 Technical Approach 4th Most Important Factor (less important than Factor 3)

4.0 TAB A - STANDARD FORM 1442 AND PROPOSAL DATA SHEET

4.1. Submit the SF 1442, completed and signed by a person authorized by the Offeror. Include the completed proposal data sheet (See Attachment 1, provided at the end of this Section). Also include joint venture agreement or LLC Certificate of Organization, Articles of Organization and the Operating Agreement, if applicable (see Section 00 21 00, paragraph 1.11).

5.0 TAB B – FACTOR 1 - SPECIALIZED EXPERIENCE

5.1. SUBMISSION REQUIREMENTS

The prime contractor and designer of record design firms for civil, architectural, structural, mechanical, electrical, telecommunications, playgrounds and fire protection design shall each demonstrate recent, relevant experience on similar projects, using Construction – Specialized Experience form – (Attachment 2), and Designer – Specialized Experience Form – (Attachment 3) at the end of the section (no more than 2 pages per project). Offerors may identify state and local government and private contracts that are similar to the Government’s requirements. If the offeror is a joint venture, each firm of the joint venture shall provide information, demonstrating experience relevant to their role on this project. Submit projects that are currently well underway (designed and at least 50% construction progress completed) or completed and turned over no longer than six (6) years preceding the date of this Solicitation. An offeror may receive credit for relevant experience under a previous business arrangement (joint venture for example) if the offeror demonstrates that their role on the submitted project is relevant to their role on this project. The offeror shall select the design firm(s). Design firms may list projects of prime contractors they have worked for or projects directly contracted with government, private or commercial customers. If projects were design-build, so identify them. Submit no more than five (5) projects for the prime contractor (whether single entity or joint venture). AM #0001… Submit no more than five (5) projects total for the design firms and consultant, if applicable, and no more than three (3) projects for any individual design firm/consultant. Submit no more than eight (8) projects total for the design firms and consultant, if applicable, and no more than three (3) projects for any individual design firm/consultant. …AM#0001 Submit relevant projects for the below facility type or similar commercial or institutional type facility.

Child Development Centers/Schools

Youth Centers

Controlled Unclassified Information (CUI) Only

Bid Inquiry Contractor Report All Inquiries

Project: FTW439 CDC Review: FTW439 Child Development Centers (00001) (sorted by CommentID ) Displaying 1 inquiry.

Id Discipline Sheet Detail Spec 9172718 Contracting 00 22 10, part 5.1

Comment Classification: Controlled Unclassified Information (CUI)

Section 00 22 10, part 5.1 states The prime contractor and designer of record design firms for civil, architectural, structural, mechanical, electrical, telecommunications, playgrounds and fire protection design shall each demonstrate recent, relevant experience on similar projects, using Construction – Specialized Experience form – (Attachment 2), and Designer – Specialized Experience Form – (Attachment 3) at the end of the section (no more than 2 pages per project). At the end of this paragraph Offerors are directed to "Submit no more than five (5) projects total for the design firms and consultant, if applicable, and no more than three (3) projects for any individual design firm/consultant."

Can the number of design firm projects be increased so all design specialties listed (civil, architectural, structural, mechanical, electrical, telecommunications, playgrounds and fire protection design) can submit at least one (1) but no more than three (3)? Or can the specification be revised to only include the designers that USACE deems most critical for evaluation?

On: Apr 09 2021.

Government Response. . Section 00 22 10 Paragraph 5.1 will be amended as follows: Submit no more than eight (8) projects total for the design firms and consultant, if applicable, and no more than three (3) projects for any individual design firm/consultant On: Apr 27 2021 Current Request Status: Request Closed