TYPE D1 TYPE D2
FLOORING AS SCHED.
CEILING AS SCHED.
3 5/8" OR 4" MTL. STUDS DIAGONAL
BRACING @ 48" O.C. MAX., ALTERNATE
BRACES. MIN. ONE SET OF BRACES PER
EACH PARTITION.
BOTTOM OF
STRUCTURE OR
ROOF DECK
PLAN VIEW PLAN VIEW
5/8" GYPSUM WALL BOARD 5/8" GYPSUM WALL BOARD
WALL BASE AS SCHED.
TYPE D5
NEW OR EXIST. CONSTRUCTION
WHERE APPLICABLE
MTL. STUD TRACK W/ 2 1/2"
X 2 1/2" X 18 GA. MTL. ANGLE
U.N.O.
3"
PLAN VIEW
SECTION VIEW
5/8" GYPSUM WALL BOARD
METAL STUDS @ 16" O.C.
5/8" GYPSUM WALL BOARD
5/8" GYPSUM WALL BOARD
METAL STUDS @ 16" O.C.
5/8" GYPSUM WALL BOARD
5/8" GYPSUM WALL BOARD
METAL STUDS @ 16" O.C.
PLAN VIEW
SECTION VIEW
5/8" GYP. BD.
TILE ON 5/8" CEMENTITIOUS BACKER
BD. ON MTL. STUDS AT 16" O.C. - USE
5/8" GYP. BD. ABOVE TILE
TILE ON 5/8" CEMENTITIOUS BACKER BD.
ON MTL. STUDS AT 16" O.C. - USE WATER
RESISTANT GYP. BD. ABOVE TILE
5/8" GYP. BD.
OMIT GYP. BD. @ CHASE SIDE
WHERE APPLICABLE
TYPE T1
SECTION VIEWSECTION VIEW
CONTRACTOR OPTION TO
EXTEND STUDS TO STRUCTURE
AND ELIMINATE BRACING - PROVIDE SLIP JOINT
FLOORING AS SCHED.
WALL BASE AS SCHED.
CONT. AC SEALANT @ EACH LAYER
OF GYP. BD.
METAL STUDS @ 16" O.C.
SOUND ATTENUATION FULL HEIGHT
METAL STUDS @ 16" O.C.
NOTE:
OMIT GYP. BD. @ CHASE SIDE
WHERE APPLICABLE
CEILING AS SCHED.
CONT. AC SEALANT @ EACH LAYER
OF GYP. BD.
5/8" GYPSUM WALL BOARD
FLOORING AS SCHED.
WALL BASE AS SCHED.
METAL STUDS @ 16" O.C.
CEILING AS SCHED. CEILING AS SCHED.
3 5/8" OR 4" MTL. STUDS DIAGONAL
BRACING @ 48" O.C. MAX., ALTERNATE
BRACES. MIN. ONE SET OF BRACES PER
EACH PARTITION.
CONTRACTOR OPTION TO
EXTEND STUDS TO STRUCTURE
AND ELIMINATE BRACING - PROVIDE SLIP JOINT
FLOORING AS SCHED.
WALL BASE AS SCHED.
NOTE:
OMIT GYP. BD. @ CHASE SIDE WHERE
APPLICABLE
PROVIDE SLIP JOINT REFER TO
TYPICAL DEFLECTION TRACK
DETAILS
BOTTOM OF
STRUCTURE OR
ROOF DECK
PLAN VIEW
SECTION VIEW
5/8" GYP. BD.
TYPE T2
FLOORING AS SCHED.
WALL BASE AS SCHED.
CONT. AC SEALANT @ EACH LAYER
OF GYP. BD.
SOUND ATTENUATION FULL HEIGHT
CEILING AS SCHED.
CONT. AC SEALANT @ EACH LAYER
OF GYP. BD.
PROVIDE SLIP JOINT REFER TO
TYPICAL DEFLECTION TRACK
DETAILS
TILE ON 5/8" CEMENTITIOUS BACKER
BD. ON MTL. STUDS AT 16" O.C. - USE
5/8" GYP. BD. ABOVE TILE
TYPE M2
CEILING
AS SCHEDULED
T.O.M.
8" CMU (GROUT FILLED AT M2A)
GYP.BD MTL STUD PARTITION ABOVE
SECTION VIEW
BOTTOM OF
STRUCTURE OR
ROOF DECK
3 LAYERS 5/8" ABUSE RESIST. GYP. BD.
ON 6" MTL STUDS @ 16" O.C. W/ SOUND
ATTENUATION FULL HEIGHT ( ALIGN ONE
SIDE W/ FACE OF CMU)
PLAN VIEW
FLOORING AS SCHED.
WALL BASE AS SCHED.
8" CMU (GROUT FILLED AT M2A)
9' - 4" AFF
U .O
.N
TILE ON 5/8" CEMENTITIOUS BACKER BD.
ON MTL. STUDS AT 16" O.C. - USE WATER
RESISTANT GYP. BD. ABOVE TILE
5/8" GYP. BD.
OMIT GYP. BD. @ CHASE SIDE
WHERE APPLICABLE
CONT. AC SEALANT @ EACH LAYER
OF GYP. BD., TOP AND BOTTOM
PROVIDE SLIP JOINT REFER TO
TYPICAL DEFLECTION TRACK
DETAILS
TYPE M3
CEILING
AS SCHEDULED
T.O.M.
8" CMU
GYP.BD MTL STUD PARTITION ABOVE
SECTION VIEW
BOTTOM OF
STRUCTURE OR
ROOF DECK
3 LAYERS 5/8" ABUSE RESIST. GYP. BD.
ON 6" MTL STUDS @ 16" O.C. W/ SOUND
ATTENUATION FULL HEIGHT ( ALIGN ONE
SIDE W/ FACE OF CMU)
PLAN VIEW
FLOORING AS SCHED.
WALL BASE AS SCHED.
8" CMU
9' - 4" AFF
CONT. AC SEALANT @ EACH LAYER
OF GYP. BD.
PROVIDE SLIP JOINT REFER TO
TYPICAL DEFLECTION TRACK
DETAILS
EXPANDED MTL LATH BEHIND ONE
LAYER OF GWB
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
FOR INTERIM REVIEW
ONLY, NOT FOR
CONSTRUCTION
TROY C. SECORD
TEXAS REGESTRATION
NO. 12994 A-601
P A
R T
IT
IO
N T
Y P
E S
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
T C
S
M P
T
D R
R
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
D1 PARTITIONS
TYPE
FIRE
RATING
STUD
SIZE DESCRIPTION STC
D1 - 3 5/8" AS SHOWN -
D2 PARTITIONS
TYPE
FIRE
RATING
STUD
SIZE DESCRIPTION STC
D2 - 3 5/8" AS SHOWN 45
D2A - 6" AS SHOWN 45
D5 PARTITIONS
TYPE
FIRE
RATING
STUD
SIZE DESCRIPTION STC
D5 - 2 1/2" AS SHOWN -
T1 PARTITIONS
TYPE
FIRE
RATING
STUD
SIZE DESCRIPTION STC
T1 - 3 5/8" AS SHOWN -
T2 PARTITIONS
TYPE
FIRE
RATING
STUD
SIZE DESCRIPTION STC
T2 - 3 5/8" 45
M2 PARTITIONS
TYPE
FIRE
RATING DESCRIPTION STC
M2 - AS SHOWN 45
M2A - AS SHOWN 50
M2B 2 HR SAME AS M2 EXCEPT W/ 2 LAYERS
GYP. BD. EACH SIDE OF MTL STUDS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
M3 PARTITIONS
TYPE
FIRE
RATING DESCRIPTION STC
M3 - AS SHOWN 45
FLUSH
F
AS SCHED.
A S
S C
H E
D
NARROW LITE
NL
AS SCHED.
A S
S C
H E
D
10" 8"
M A
X
A S
S C
H E
D
AS SCHED.
OVERHEAD COILING DOOR
OH
GLAZING
AS SCHED.
CLASS 5 ARMORY VAULT DOOR & DAY GATE
AV
AS SCHED.
11" 1' - 2"
11"
A S
S C
H E
D
AS SCHED.
COUNTER SHUTTER
OH 2
AS SCHED.
FIN. FLR.
HOLLOW METAL FRAME
H2
W/ 1/2" BACKBEND
A S
S C
H E
D
2" AS SCHED. 2"
PROFILE
VARIES
1/2" 1/2"
1 15/16"1 15/16"
/8
HOLLOW METAL FRAME
H1
W/ 1/2" BACKBEND
A S
S C
H E
D
2" AS SCHED. 2"
PROFILE
VARIES
1/2" 1/2"
1 15/16"1 15/16"
/8
HOLLOW METAL FRAME
H3
W/ 1/2" BACKBEND
A S
S C
H E
D
2" AS SCHED. 2"
1' - 4"
2"
PROFILE
VARIES
1/2" 1/2"
1 15/16"1 15/16"
/8
A
HORIZONTAL SLIDER
B
FIXED
F.F.
5' - 0"
F.F.
5' - 0"
DOOR SCHEDULE NOTES
1. SEE FLOOR PLANS FOR DOOR LOCATIONS AND SWINGS.
2. PROVIDE SEALANT AROUND FULL PERIMETER OF FRAMES, BOTH
SIDES OF PARTITIONS, ETC.
3. VAULT DOOR HARDWARE PROVIDED BY VAULT DOOR
MANUFACTURER. DOORS SHALL BE SUPPLIED WITH GSA APPROVED
COMBINATION LOCKS (KABA MAS OR EQUAL) COMPLIANT WITH
CURRENT UNIFIED FEDERAL GUIDE SPECIFICATIONS (UFGS)
STANDARDS APPROPRIATE FOR VAULT DOOR TYPE.
4. EXTERIOR OVERHEAD COILING DOORS TO BE ELECTRICALLY
OPERATED WITH THE CAPABILITY OF LOCKING DOOR OPEN AT 1’-0”
A.F.F.
5. NO THRESHOLD / TRANSITION REQUIRED AT DOORWAYS IN SPACES
HAVING THE SAME FLOOR FINISH ON BOTH SIDES OF THE DOOR.
SPACES HAVING DIFFERENT FLOOR FINISHES WILL REQUIRE
TRANSITION.
DOOR SCHED. ABB
GLZ GLAZING
HM HOLLOW METAL
STL STEEL
WD WOOD
GLAZING SCHEDULE
FG-1 1/4" (6mm) CLEAR (FULLY TEMPERED) GLASS
IG-1 1" INSULATED - TINTED GLASS UNIT LOW- E WITH/ .030 PVB
LSG-1 1/4" LAMINATED SAFETY GLASS WITH / .030 PVB
COMMENTS
1. PAIR OF DOORS
2. CLASS 5 VAULT DOOR WITH DAY GATE, INSTALL PER
MANUFACTURER’S STANDARD DETAILS
a. ARMS VAULT TO RECEIVE CLASS 5A VAULT DOOR
b. COMSEC VAULT TO RECEIVE CLASS 5V VAULT DOOR
c. DAY GATE: STL MESH, DEADBOLT OUTSIDE WITH THUMB
LATCH INSIDE
3. OVERHEAD DOOR HARDWARE & GUIDES/FRAME ASSEMBLY PER DOOR
MANUFACTURER.
4. INTERIOR DOOR FINISH TO MATCH EXTERIOR.
5. SECURITY DOOR COMPLYING WITH SECURE ROOM STANDARDS OF AR
380-5. 16 GA (MIN.) HOLLOW METAL DOOR WITH NON-REMOVABLE PIN
HINGES. PROVIDE LOCKMASTERS LKM 7000 SINGLE MOTION LIFE
SAFETY EXIT DEVICE MEETING FF-L-2890A (TYPE IV) WITH DIAL-TYPE
ELECTRO-MECHANICAL COMBINATION LOCK MEETING FF-L-2740A.
6. PROVIDE PAD-LOCKABLE SLIDING BOLTS ON INTERIOR OF MANUALLY
OPERATED OVERHEAD COILING DOORS EACH JAMB.
7. PROVIDE 14” X 14” LOUVERS IN EACH LEAF.
8. PAINT EXISTING DOOR AND FRAME.
9. PROVIDE NEW HARDWARE SET AS NOTED.
10. BASIS OF DESIGN FOR COUNTERTOP DOOR IS CORNELL SOUND
BARRIER DOOR UTILIZING URETHANE-FOAM FILLED METAL SLATS &
PERIMETER SEALS.
11. RE-KEY EXISTING DOOR HARDWARE TO MATCH NEW.
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
FOR INTERIM REVIEW
ONLY, NOT FOR
CONSTRUCTION
TROY C. SECORD
TEXAS REGESTRATION
NO. 12994 A-602
S C
H E
D U
L E
S
D O
O R
A N
D W
IN
D
O W
T Y
P E
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
T C
S
M P
T
D R
R
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
DOOR SCHEDULE
DOOR NO. TYPE
DOOR
FIRE
RATING
FRAME
HARDWAR
E COMMENTS:
SIZE
MATERIAL FINISH
GLAZIN
G TYPE MATERIAL FINISH GLAZING
DETAILS
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
101.1 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
101.2 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
102 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT FG-1 - H2 HM PT D1/A-604 B1/A-604 A1/A-603 HW - 6
103 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H3 HM PT FG-1 D1/A-603 B1/A-603 A1/A-603 HW - 7
104 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H3 HM PT FG-1 D1/A-603 B1/A-603 A1/A-603 HW - 7
105 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D3/A-603 B3/A-603 A3/A-603 HW - 11
106 F 5' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D3/A-603 B3/A-603 A3/A-603 HW - 1 NOTE 1, 7
107 F 6' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D3/A-603 B3/A-603 A3/A-603 HW - 1 NOTE 1, 7
108 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
109 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 10 NOTE 5
110 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 4
111 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 5
112 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 5
113 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT FG-1 - H2 HM PT D1/A-604 B1/A-604 A1/A-603 HW - 6
114 F 6' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 1 NOTE 1, 7
115 F 6' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 3 NOTE 1
116 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 8
117.1 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
117.2 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
117.3 EXIST 3' - 0" 7' - 0" 1 3/4"
118.1 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
118.2 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
118.3 EXIST 3' - 0" 7' - 0" 1 3/4"
119 AV 3' - 0" 7' - 0" 1 3/4" STL PT - - - STL PT NOTE 2
120 AV 3' - 0" 7' - 0" 1 3/4" STL PT - - - STL PT NOTE 2
201.1 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT LSG-1- - H1 HM PT D2/A-603 B2/A-603 A1/A-603 HW - 2
201.2 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT LSG-1- - H1 HM PT D2/A-603 B2/A-603 A1/A-603 HW - 2
202 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H1 HM PT D1/A-603 B1/A-603 A1/A-603 HW - 6
203 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT FG-1 - H1 HM PT D1/A-603 B1/A-603 A1/A-603 HW - 6
204.1 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT FG-1 - H1 HM PT D1/A-603 B1/A-603 A1/A-603 HW - 9
204.2 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT FG-1 - H1 HM PT D1/A-603 B1/A-603 A1/A-603 HW - 9
OH102 OH2 3' - 0" 4' - 4" D2/A-605 B2/A-605 A2/A-605 NOTE 6, 10
OH108.1 OH 10' - 0" 10' - 0" 3" STL PT - - - STL PT D3/A-604 B3/A-604 A3/A-604 NOTE 6
OH108.2 OH2 3' - 0" 4' - 4" D1/A-605 B1/A-605 A1/A-605 NOTE 6, 10
OH115.1 OH 10' - 0" 9' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 6
OH115.2 OH2 3' - 0" 4' - 4" D2/A-604 B2/A-604 A2/A-604 NOTE 6, 10
OH116 OH 10' - 0" 9' - 0" 3" STL PT - - - STL PT D3/A-604 B3/A-604 A3/A-604 NOTE 3,6
OH117.1 OH 14' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
OH117.2 OH 14' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
OH117.3 OH 14' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604
OH118.1 OH 14' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
OH118.2 OH 24' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
OH118.3 OH 16' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
OH118.4 OH 14' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
OH118.5 OH 24' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
WINDOW SCHEDULE
Mark
R.O.
Type
FRAME GLAZING DETAILS
Head Height Remarks (See Notes Below)Width Height Finish Material Type Thickness Head Jamb
Window _Sill
A 5' - 0" 3' - 0" HORIZONTAL SLIDING DB AL IG-1 1" D2/A-606 A2/A-606 B2/A-606 7' - 4"
B 5' - 0" 3' - 0" WINDOW FIXED DB AL IG-1 1" D1/A-606 B1/A-606 A1/A-606 7' - 4"
B.1 5' - 0" 3' - 0" WINDOW FIXED DB AL IG-1 1" D4/A-606 B4/A-606 A4/A-606 7' - 4"
1/4" = 1'-0"A-602
A1 DOOR TYPES
1/4" = 1'-0"A-602
A2 FRAME TYPES
1/4" = 1'-0"A-602
B1 WINDOW TYPES
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
0' 4' 8'
GRAPHIC SCALE 1/4" = 1'-0"
2'1'
PARTITION AS SCHED.
CAULK EACH SIDE
DOOR AND
FRAME
AS SCHEDULED.
JAMB BEYOND
SMOKE
GASKET
WHERE
SCHED.
EQ EQ
REFER PARTITION
SCHED.
A S
S C
H E
D
A S
S C
H E
D U
L E
D
PARTITION AS SCHED.
DOUBLE STUDS @
EACH JAMB
JAMB ANCHORS
3 PER JAMB
MIN.
DOOR AND
FRAME AS
SCHEDULED
CAULK EACH SIDE
SMOKE
GASKET
WHERE
SCHED.
REFER PARTITION
SCHED.
EQ EQ
A S
S C
H E
D U
L E
D
DOOR AND FRAME AS
SCHEDULED.
FLOOR FINISH AS SCHED.
AUTO. DOOR BOTTOM
WHERE SCHED.
/8
PARTITION SCHED.
REFER
A S
S C
H E
D U
L E
D
REF. WALL SECTIONS
DOOR AND
FRAME
AS SCHEDULED.
JAMB BEYOND
PREFINISHED FLASHING
CEE GIRT
CAULK
SEALANT
PANEL
FLASHIN
G & DRIP
ALUM.
WEATHER-
STRIP
5 3/4"
A S
S C
H E
D U
L E
D
JAMB ANCHORS
3 PER JAMB
MIN.
DOOR AND
FRAME AS
SCHEDULED
REF. WALL SECTIONS
CEE GIRT
PREFINISHED FLASHING
CAULK
SEALANT
MTL. JAMB
TRIM
ALUM.
WEATHER-
STRIP
5 3/4"
AS SCHED.1/4"
EXISTING
MASONRY
JAMB BEYOND
DOOR & FRAME
AS SCHED.
/1
A S
S C
H E
D
STL. LINTEL - RE: STRUCT.
AS SCHED.1/4"
EXISTING
MASONRY
A S
S C
H E
D
JAMB BEYOND
DOOR & FRAME
AS SCHED.
CONT. BACKER ROD
& SEALANT
CONT. CAULK
A S
S C
H E
D
DOOR AND FRAME AS
SCHED.
FLOOR FINISH
AS SCHED.
ALUM. THRESHOLD AS
SCHED. - SET IN A
FULL BED OF MASTIC
/2
CONC. FOUNDATION
RE: STRUCT
DOOR BOTTOM AS
SCHED.
BLOCK-OUT IN SLAB
AS INDICATED1 1/2"
A S
S C
H E
D U
L E
D
DOOR AND
FRAME AS
SCHEDULED
SEALANT
5 3/4"
GROUT FILLED CMU
STL. LINTEL
STL. PLATE
A S
S C
H E
D U
L E
D
JAMB ANCHORS
3 PER JAMB
MIN.
DOOR AND
FRAME AS
SCHEDULED
SEALANT
5 3/4"
SEALANT
GROUT FILLED CMU
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
FOR INTERIM REVIEW
ONLY, NOT FOR
CONSTRUCTION
TROY C. SECORD
TEXAS REGESTRATION
NO. 12994 A-603
D O
O R
D E
T A
IL
S
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
T C
S
M P
T
D R
R
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
3" = 1'-0"A-603
D1 HEAD DETAIL
3" = 1'-0"A-603
B1 JAMB DETAIL
3" = 1'-0"A-603
A1 SILL DETAIL
3" = 1'-0"A-603
D2 HEAD DETAIL
3" = 1'-0"A-603
B2 JAMB DETAIL
0' 6" 1'
GRAPHIC SCALE 3" = 1'-0"
3"
3" = 1'-0"A-603
D3 HEAD DETAIL
3" = 1'-0"A-603
B3 JAMB DETAIL
3" = 1'-0"A-603
A3 THRESHOLD DETAIL
3" = 1'-0"A-603
D4 CMU HEAD DETAIL
3" = 1'-0"A-603
B4 CMU JAMB DETAIL
A S
S C
H E
D U
L E
D
DOOR AND
FRAME AS
SCHEDULED
SEALANT
5 3/4"
FURING PARTITION
AS SCHED.; WHERE
INDICATED ON PLAN
SEALANT
GROUT FILLED CMU
CORNER BEAD
STL. PLATE
A S
S C
H E
D U
L E
D
JAMB ANCHORS
3 PER JAMB
MIN.
DOOR AND
FRAME AS
SCHEDULED
SEALANT
5 3/4"
FURING PARTITION
AS SCHED.; WHERE
INDICATED ON PLAN
SEALANT
GROUT FILLED CMU
CORNER BEAD
A S
S C
H E
D
REFER TO WALL SECTION
STL. CHANNEL -
PRIME & PAINT
OVERHEAD COILING
DOOR & FRAME SYSTEM
AS SCHED.
STL. CHANNEL JAMB -
BEYOND
REFER TO WALL SECTION
OVERHEAD SECTIONAL
DOOR & FRAME SYSTEM
AS SCHED.
A S
S C
H E
D
PREFINISHED MTL.
JAMB TRIM
STL. CHANNEL @ EA.
JAMB AND HEAD
GROUT FILLED CMU
MTL. JAMB
TRIM
A S
S C
H E
D
OVERHEAD SECTIONAL
DOOR & FRAME SYSTEM
AS SCHED.
FINISH FLOOR AS SCHED.
3/4" ASPHALT IMPREGNATED
FIBER EXP. JT. MATERIAL W/
SEALANT
SLOPE OVERHEAD DOOR
SILL - RE: STRUC.
SLOPE
REFER STRUC.
JAMB - BEYOND
/2
A S
S C
H E
D
REFER TO WALL SECTION
STL. CHANNEL -
PRIME & PAINT
OVERHEAD COILING
DOOR & FRAME SYSTEM
AS SCHED.
PREFINISHED MTL.
JAMB TRIM
STL. CHANNEL JAMB -
BEYOND
REFER TO WALL SECTION
OVERHEAD SECTIONAL
DOOR & FRAME SYSTEM
AS SCHED.
A S
S C
H E
D
PREFINISHED MTL.
JAMB TRIM
STL. CHANNEL @ EA.
JAMB AND HEAD
MTL. BLDG. GIRT (BEYOND)
MTL. JAMB
TRIM
HOOD
FASCIA
STOPPER
STEEL BOTTOM BAR W/
VINYL ASTRAGAL
ENDS OF
HEAD AND
SILL TO BE
CLOSED
JAMB BEYOND
REF. WALL SECTIONS
SILL DEPTH
JAMB ANCHOR
SILL BEYOND
REF. WALL SECTIONS
STAINLESS STEEL SILL W/
WOOD BLOCKING
JAMB DEPTH
JAMB BEYOND
REF. WALL SECTIONS
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
FOR INTERIM REVIEW
ONLY, NOT FOR
CONSTRUCTION
TROY C. SECORD
TEXAS REGESTRATION
NO. 12994 A-604
D O
O R
D E
T A
IL
S
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
T C
S
M P
T
D R
R
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
0' 6" 1'
GRAPHIC SCALE 3" = 1'-0"
3"
3" = 1'-0"A-604
D1 CMU HEAD DETAIL
3" = 1'-0"A-604
B1 CMU JAMB DETAIL
1 1/2" = 1'-0"A-604
D3 O.H. HEAD DETAIL
3" = 1'-0"A-604
B3 JAMB DETAIL
3" = 1'-0"A-604
A3 O.H. SILL DETAIL
1 1/2" = 1'-0"A-604
D4 HEAD DETAIL
3" = 1'-0"A-604
B4 JAMB DETAIL
3" = 1'-0"A-604
D2 O.H. HEAD SHUTTER DETAIL
3" = 1'-0"A-604
B2 O.H. JAMB SHUTTER DETAIL
3" = 1'-0"A-604
A2 O.H. SILL SHUTTER DETAIL
HOOD
FASCIA
STOPPER
STEEL BOTTOM BAR W/
VINYL ASTRAGAL
ENDS OF
HEAD AND
SILL TO BE
CLOSED
JAMB BEYOND
EXISTING WALL
SILL DEPTH
JAMB ANCHOR
SILL BEYOND
EXISTING WALL
STAINLESS STEEL SILL W/
WOOD BLOCKING
JAMB DEPTH
JAMB BEYOND
EXISTING WALL
HOOD
FASCIA
STOPPER
STEEL BOTTOM BAR W/
VINYL ASTRAGAL
ENDS OF
HEAD AND
SILL TO BE
CLOSED
JAMB BEYOND
REF. WALL SECTIONS
FURING PARTITION
AS SCHED.; WHERE
INDICATED ON PLAN
SILL DEPTH
JAMB ANCHOR
SILL BEYOND
REF. WALL SECTIONS
FURING PARTITION
AS SCHED.; WHERE
INDICATED ON PLAN
STAINLESS STEEL SILL W/
WOOD BLOCKING
JAMB DEPTH
JAMB BEYOND
REF. WALL SECTIONS
FURING PARTITION
AS SCHED.; WHERE
INDICATED ON PLAN
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
FOR INTERIM REVIEW
ONLY, NOT FOR
CONSTRUCTION
TROY C. SECORD
TEXAS REGESTRATION
NO. 12994 A-605
D O
O R
D E
T A
IL
S
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
D e s ig n e r
A u th o r
C h e c k e r
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
3" = 1'-0"A-605
D1 O.H. HEAD SHUTTER DETAIL
3" = 1'-0"A-605
B1 O.H. JAMB SHUTTER DETAIL
3" = 1'-0"A-605
A1 O.H. SILL SHUTTER DETAIL
3" = 1'-0"A-605
D2 O.H. HEAD SHUTTER DETAIL
3" = 1'-0"A-605
B2 O.H. JAMB SHUTTER DETAIL
3" = 1'-0"A-605
A2 O.H. SILL SHUTTER DETAIL
JAMB BEYOND
WINDOW & FRAME
AS SCHED.
CONT. CAULK
PARTITION AS
SCHED.; WHERE
INDICATED ON PLAN
STL. LINTEL - RE: STRUCT.
JAMB BEYOND
WINDOW & FRAME
AS SCHED.
CONT. CAULK
PARTITION AS
SCHED.; WHERE
INDICATED ON PLAN
JAMB BEYOND
WINDOW & FRAME
AS SCHED.
CONT. CAULK
PARTITION AS
SCHED.; WHERE
INDICATED ON PLAN
CONT. WD. BLOCKING
JAMB BEYOND
WINDOW & FRAME
AS SCHED.
CONT. CAULK
PARTITION AS
SCHED.; WHERE
INDICATED ON PLAN
CORNER GUARD
EXIST. WALL
JAMB BEYOND
WINDOW & FRAME
AS SCHED.
CONT. CAULK
PARTITION AS
SCHED.; WHERE
INDICATED ON PLAN
CORNER GUARD
EXIST. WALL
JAMB BEYOND
WINDOW & FRAME
AS SCHED.
CONT. CAULK
PARTITION AS
SCHED.; WHERE
INDICATED ON PLAN
CORNER GUARD
EXIST. WALL
A S
S C
H E
D U
L E
D
REF. WALL SECTIONS
CEE GIRT
PANEL
FLASHIN
G & DRIP
JAMB BEYOND
WINDOW & FRAME
AS SCHED.
CONT. CAULK
CORNER BEAD
REF. WALL SECTIONS
CEE GIRT
MTL. JAMB
TRIM
JAMB BEYOND
WINDOW & FRAME
AS SCHED.
CONT. CAULK
CORNER BEAD
A S
S C
H E
D U
L E
D
REF. WALL SECTIONS
CEE GIRT
FLASHING
JAMB BEYOND
WINDOW & FRAME
AS SCHED.
CONT. CAULK
CORNER BEAD
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
FOR INTERIM REVIEW
ONLY, NOT FOR
CONSTRUCTION
TROY C. SECORD
TEXAS REGESTRATION
NO. 12994 A-606
W
IN
D O
W S
D E
T A
IL
S
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
T C
S
M P
T
D R
R
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
0' 6" 1'
GRAPHIC SCALE 3" = 1'-0"
3"
3" = 1'-0"A-606
D2 WINDOW HEAD DETAIL - SLIDING
3" = 1'-0"A-606
A2 WINDOW JAMB DETAIL - SLIDING
3" = 1'-0"A-606
B2 WINDOW SILL DETAIL - SLIDING
3" = 1'-0"A-606
D1 WINDOW HEAD DETAIL - FIXED
3" = 1'-0"A-606
B1 WINDOW JAMB DETAIL - FIXED
3" = 1'-0"A-606
A1 WINDOW SILL DETAIL - FIXED
3" = 1'-0"A-606
D4 WINDOW HEAD DETAIL - FIXED
3" = 1'-0"A-606
B4 WINDOW JAMB DETAIL - FIXED
3" = 1'-0"A-606
A4 WINDOW SILL DETAIL - FIXED
GENERAL NOTES
1. ENSURE FLOOR IS READY TO RECEIVE FINISHES
PER ADHESIVE MANUFACTURER'S
RECOMMENDATIONS BEFORE INSTALLING.
2. ENSURE ALL TRANSITIONS AT FLOOR FINISHES ARE
NO GREATER THAN 1/2"
3. CORNER GUARDS SHALL BE INSTALLED ON ALL
OUTSIDE CORNERS AND COLUMN WRAPS.
ABBREVIATIONS
ACT ACOUSTICAL CEILING TILE
SCONC CONCRETE SEALER - CLEAR
CPT CARPET MODULAR TILE
CTW CERAMIC (OR PORCELAIN) TILE - WALL
CTB CERAMIC (OR PORCELAIN) TILE - BASE
CTF CERAMIC (OR PORCELAIN) TILE - FLOOR
EXP EXPOSED STRUCTURE
EXST EXIST STRUCTURE
PT PAINT: WALL
RB RUBBER BASE
REM RECESSED ENTRY MAT
SDT STATIC DISSIPATIVE TILE
VCT VINYL COMPOSITION TILE
CG VINYL CORNER GUARD
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
A T
T A
C H
M E
N T
B
A-610
F
IN
IS
H
P L A
N A
N D
S C
H E
D U
L E
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
T C
S
M P
T
D R
R
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
FINISH SCHEDULE
WT ROOM NAME FLOOR
WALL FINISH BASE FINISH FLOOR CEILING
NOTES & REMARKS (SEE NOTES)NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST MAT. MAT. HEIGHT
101 CORRIDOR FIN FLR 1ST PT PT PT PT RB RB RB RB SCONC ACT 9' - 0"
102 ADMIN SHOP CONTROL FIN FLR 1ST PT PT PT PT RB RB RB RB VCT ACT 9' - 0"
103 OFFICE 1 FIN FLR 1ST PT PT PT PT RB RB RB RB VCT ACT 9' - 0"
104 OFFICE 2 FIN FLR 1ST PT PT PT PT RB RB RB RB VCT ACT 9' - 0"
105 COMM 1 FIN FLR 1ST PT PT PT PT - - - - SCONC PT. EXST -
106 ELEC FIN FLR 1ST PT PT PT PT - - - - SCONC PT. EXST -
107 MECH FIN FLR 1ST PT PT PT PT - - - - SCONC PT. EXST -
108 TOOL ROOM FIN FLR 1ST PT PT PT PT - - - - SCONC PT. EXST -
109 NON-SENS SECURE
STOR
FIN FLR 1ST PT PT PT PT RB RB RB RB SCONC PT. EXST -
110 JAN FIN FLR 1ST PT PT PT PT/CTW RB RB RB RB SCONC PT. GWB 9' - 0"
111 WOMENS FIN FLR 1ST PT PT PT PT/CTW CTB CTB CTB CTB CTF PT. GWB 9' - 0"
112 MENS FIN FLR 1ST PT PT/CTW PT PT/CTW CTB CTB CTB CTB CTF PT. GWB 9' - 0"
113 BREAK / TRAINING FIN FLR 1ST PT PT PT PT RB RB RB RB VCT ACT 9' - 0"
114 FLUID DISTR FIN FLR 1ST PT PT PT PT - - - - SCONC PT. EXST -
115 COMBAT SPARES FIN FLR 1ST PT PT PT PT - - - - SCONC PT. EXP -
116 CONSOLIDATED BENCH
REPAIR
FIN FLR 1ST PT PT PT PT - - - - SCONC PT. EXP -
117 MAINTENANCE AREA FIN FLR 1ST PT - PT - - - - - SCONC - - PAINT ALL PREVIOUSLY PAINTED SURFACES
118 REPAIR AREA FIN FLR 1ST - PT - PT - - - - SCONC - - PAINT ALL PREVIOUSLY PAINTED SURFACES
119 ARMS VAULT FIN FLR 1ST PT PT PT PT - - - - SCONC PT. EXP -
120 COMSEC VAULT FIN FLR 1ST PT PT PT PT - - - - SCONC PT. EXP -
201 CORRIDOR FIN FLR 2ND PT PT PT PT RB RB RB RB VCT ACT 9' - 0"
202 COMM 2 FIN FLR 2ND PT PT PT PT RB RB RB RB VCT ACT 9' - 0"
203 UNASSIGNED FIN FLR 2ND PT PT PT PT RB RB RB RB VCT ACT 9' - 0"
204 TRAINING ROOM FIN FLR 2ND PT PT PT PT RB RB RB RB VCT ACT 9' - 0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
HORSEPOWER
HTG
HP
HEATING
WATER GAUGE
WB
WG
WET BULB
ENERGY MONITORING AND CONTROL SYSTEM
ABBREVIATIONS
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)
CC COOLING COIL
EFFICIENCYEFF
HEATING COIL
GALLONS PER MINUTE
FEET PER MINUTEFPM
HC
HVAC
HZHZ
GPM
FT
HERTZ
FEET, FOOT
FLEX
F
EMCS
EXH
EL
FLEXIBLE
FAHRENHEIT
ELEVATION
EXHAUST
DIRECT DIGITAL CONTROL
DIRECT EXPANSION
ELECTRIC/ELECTRICAL
ENTERING AIR TEMPERATURE
CUBIC FEET PER MINUTE
CONNECTION
CONDENSATE DRAIN
DWGS
EAT
ELEC
DDC
DEG
DX
DRAWINGS
DEGREE
CONN
DIA
DB
dB
CFM
CD
DIAMETER
DRY BULB
DECIBELS
HVAC SYMBOLS
BOTTOM OF DUCT
BRITISH THERMAL UNIT PER HOUR
BRAKE HORSEPOWER
AIR CONDITIONING
ARCHITECTURE/ARCHITECTURAL
APPROXIMATELY
ABOVE FINISHED FLOOR
BOD
BTUH
BHP
ASHRAE
A/C
ARCH
AFF
APPROX
NOISE CRITERIANC
SMACNA
SUPPLY AIR
VOLUME DAMPER
VARIABLE AIR VOLUME
UNLESS NOTED OTHERWISE
THERMOSTAT
SQUARE FEET
TEMPERATURE
STATIC PRESSURE
WATER COLUMN
VARIABLE FREQUENCY DRIVE
TYP TYPICAL
VFD
VD
WC
WTR
VAV
UNO
WATER
SA
T-STAT
TEMP
SP
SQ FT
NORMALLY OPEN
NORMALLY CLOSED
POUNDS PER SQUARE INCH
RETURN AIR
OUTSIDE AIR
NOT TO SCALE
REVOLUTIONS PER MINUTE
RE
RA
RPM
PSI
PLBG
P/PH
REFER/REFERENCE
PLUMBING
PHASE
NO
N.C.
N.O.
OA
NTS
NOM
NUMBER
NOMINAL
NATIONAL FIRE PROTECTION ASSOC.
MECHANICAL
LEAVING WATER TEMPERATURE
THOUSANDS BTU's PER HOUR
MINIMUM CIRCUIT AMPACITY
LEAVING AIR TEMPERATURE
LWT
NFPA
MIN
MBH
MECH
MAX
MCA
MINIMUM
MAXIMUM
KW
LAT
KILOWATT
CENTIGRADE
C
WT WATTS
ENTERING WATER TEMPERATUREEWT
HEATING, VENTILATION AND AIR CONDITIONING
SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOC.
AMERICAN SOCIETY OF HEATING,
REFRIGERATION, AND
AIR CONDITIONING ENGINEERS
DUCTWORK SYMBOLS
DUCTWORK SIZE TRANSITION.
FLARED SPIN-IN TAP WITH DAMPER
RADIUS DUCTWORK ELBOW
ROUND OR RECTANGULAR
SPIN-IN TAP WITH DAMPER
RADIUS DUCTWORK ELBOW
ROUND OR RECTANGULAR
FLEXIBLE DUCT
RETURN/TRANSFER AIR DUCT
SUPPLY OR OUTSIDE AIR DUCT
RELIEF OR EXHAUST AIR DUCT
ROUND DUCTWORK
RETURN/TRANSFER AIR GRILLE
EXHAUST GRILLE
SUPPLY AIR PLENUM SLOT DIFFUSER
IN-LINE 90 DEGREE RISE
SD - SMOKE DAMPER
CD - COMBINATION FIRE/SMOKE DAMPER
RELIEF OR EXHAUST AIR DUCT DOWN
MANUAL VOLUME (BALANCE) DAMPER
90° ELBOW WITH TURNING VANES
RELIEF OR EXHAUST AIR DUCT UP
RETURN AIR DUCT DOWN
INCLINED DROP IN DUCT
INCLINED RISE IN DUCT
FD - FIRE DAMPER
MOTORIZED DAMPER
OR DROP IN DUCT
SUPPLY OR OUTSIDE AIR DUCT UP
SUPPLY OR OUTSIDE AIR DUCT DOWN
FLEXIBLE DUCT CONNECTION
RETURN AIR DUCT UP
TO EQUIPMENT
12/12
12"
FD
M
DN
UP
ROUND DUCT BRANCH TAKE-OFF FROM
RECTANGULAR OR FLAT OVAL MAIN WITH
CONICAL TAP. PROVIDE BALANCE DAMPER
FOR LOW PRESSURE DUCTWORK ONLY
RECTANGULAR DUCTWORK BRANCH TAKE-OFF
W/DAMPER AND 45 DEGREE BRANCH INLET
RECTANGULAR DUCTWORK. SIZE INDICATED IN
INCHES, FIRST NUMBER IS SIDE SHOWN
SUPPLY AIR DIFFUSER - ARROWS INDICATE
PATTERN. NO ARROWS SHOWN EQUALS
4-WAY.
GENERAL NOTES
18.
17.
16.
15.
14.
13.
12.
DE = CIRCULAR EQUIVALENT OF RECTANGULAR DUCT
11.
IN INCHES
10.
9.
8.
6.
7.
5.
3.
4.
2.
1.
19.
B = LENGTH OF OTHER SIDE OF DUCT IN INCHES
FOR ALL MECHANICAL EQUIPMENT PROVIDE LOCAL DISCONNECT
MOUNTED ON UNIT OR INTEGRAL TO UNIT CONTROL PANEL.
INSULATE BACKS AND PLENUMS OF SUPPLY AIR DEVICES WITH
MINIMUM 1" MINERAL FIBER.
PROVIDE OSHA-REQUIRED CLEARANCES AROUND ALL HVAC
EQUIPMENT AND COMPONENTS FOR PERSONNEL ACCESS AND
MAINTENANCE.
PROVIDE FIRE DAMPERS IN DUCTWORK AT ALL FIRE BARRIER
PENETRATIONS.
PROVIDE FIRE RESISTANT FLEXIBLE CONNECTION WHENEVER
DUCTWORK IS CONNECTED TO MOTORIZED EQUIPMENT.
DUCT MATERIAL SHALL BE ZINC-COATED STEEL WITH METAL AND
GALVANIZING THICKNESS AS PER SMACNA CONSTRUCTION
STANDARDS.
PIPING HANGERS AND SUPPORTS - ALL HANGERS AND
SUPPORTS SHALL COMPLY WITH MANUFACTURER'S
STANDARDIZATION SOCIETY (MSS) STANDARDS. VERTICAL PIPES
MUST BE SUPPORTED AT EACH FLOOR WITH PIPE CLAMPS.
THIS PROJECT IS DESIGNED BASED ON THE FOLLOWING CODES:
UNIFIED FACILITIES CRITERIA (UFC), USACE FACILITIES
STANDARDIZATION PROGRAM - TACTICAL EQUIPMENT
MAINTENANCE FACILITIES (TEMF) DESIGN STANDARD,
INTERNATIONAL MECHANICAL CODE 2015, INTERNATIONAL
ENERGY CONSERVATION CODE 2015.
UTILIZE LONG RADIUS ELBOWS WHERE SPACE PERMITS UNLESS
OTHERWISE NOTED. ALL RECTANGULAR ELBOWS SHALL CONTAIN
TURNING VANES.
ALL DUCT SIZES SHOWN ON THE DRAWINGS ARE NET INSIDE
CLEAR DIMENSIONS.
COORDINATE WITH OTHER UTILITIES TO AVOID INTERFERENCES
WHEN INSTALLING DUCTWORK, PIPING AND EQUIPMENT.
A = LENGTH OF ONE SIDE OF DUCT IN INCHES
TO RESOLVE FIELD PROBLEMS IN ROUTING DUCTWORK THE
CONTRACTOR SHALL USE THE SAME CIRCULAR EQUIVALENT
DIAMETER TO TRANSFORM DUCT SIZE FROM THAT SPECIFIED ON
THE DRAWINGS.
ALL DUCTWORK SHALL BE CONSTRUCTED, SEALED AND
INSTALLED IN CONFORMANCE TO SMACNA DUCT CONSTRUCTION
STANDARDS.
PAINT ALL EQUIPMENT VISIBLE THRU AIR DEVICES MATTE BLACK.
PROVIDE MODIFICATIONS AND ACCESSORIES AS REQUIRED AND
RECOMMENDED BY THE MANUFACTURER TO ASSURE PROPER
OPERATION OF EQUIPMENT.
VERIFY DIMENSIONS, LOCATIONS, ELEVATIONS AND
CONFIGURATION OF ALL ITEMS ASSOCIATED WITH THE
INSTALLATION OF THE DUCTWORK AND EQUIPMENT.
FURNISH AND INSTALL ALL EQUIPMENT AS PER
MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS.
PROVIDE MANUAL VOLUME DAMPERS IN DUCTWORK AT ALL
DUCT SPLITS, BRANCH RUNOUTS AND DUCT COLLARS FOR
REGISTERS AND DIFFUSERS.
DE =
1.30 (AB)
(A + B)
0.625
0.250
20. PROVIDE DIELECTRIC FITTINGS BETWEEN PIPES OF DIFFERENT
METALS.
PIPING SYMBOLS
PIPE FLANGE
BALL VALVE
TEE OUTLET DOWN
DIRECTION OF FLOW
DIRECTION OF SLOPE
UNION
VALVE IN RISE
TEE OUTLET UP
VALVE IN CENTER DROP
VALVE IN DROP
ELBOW DOWN
ELBOW UP
PRESSURE GAUGE
THERMOMETER
FLEXIBLE CONNECTION
WITH GAUGE COCK
PRESSURE GAUGE
PRESSURE SWITCH
FLOW SWITCH
CAP ON END LINE
FS
PS
DOUBLE LINE
D U
C T
W O
R K
P
IP
IN
G
EXISTING TO BE
REMOVED
DEMOLITION PLANS SINGLE LINE
PLAN SYMBOLOGY
DOUBLE LINE
D U
C T
W O
R K
P
IP
IN
G
NEW
NEW
NEW PLANS SINGLE LINE
EXISTING TO BE
REMOVED
"X" INDICATES ZONE)
(LOCAL CONTROL
SP
DIFFUSER/GRILLE/REGISTER LABEL:
"A" - TYPE/DESIGNATION
"200" - AIRFLOW (CFM)
THERMOSTAT
H
T
TT
DRAWING NOTE REFERENCE
DIAMETER/PHASE
DUCT SMOKE DETECTOR
P
S
C
MISCELLANEOUS
X
A 200
DUCT MOUNTED STATIC
PRESSURE SENSOR
HUMIDITY SENSOR
TEMPERATURE SENSOR
CO2 SENSOR
PRESSURE SENSOR
SENSOR WITH LOCKING
PROTECTIVE GUARD
POINT OF NEW
CONNECTION BETWEEN
NEW AND EXISTING WORK
FIRESTATF
PIPING SYMBOLS
PROVIDE MERV 8 FILTERS DURING CONSTRUCTION. REPLACE
TEMPORARY CONSTRUCTION FILTERS AS NEEDED. REPLACE WITH
NEW FILTERS AT SUBSTANTIAL COMPLETION. NEW FILTERS SHALL
BE MERV 8 UNLESS OTHERWISE NOTED.
GRH GAS FIRED RADIANT HEATER
EXHAUST FANEF
CU CONDENSING UNIT
AHU AIR HANDLING UNIT
EQUIPMENT DESIGNATIONS
HVU HEATING VENTILATOR UNIT
DOAS DEDICATED OUTSIDE AIR SYSTEM
UH ELECTRIC UNIT HEATER
VE VEHICLE EXHAUST FAN
THIS DOCUMENT IS RELEASED FOR THE
PURPOSE OF INTERIM REVIEW UNDER THE
AUTHORITY OF:
TEXAS NO: ON DATE:
IT IS NOT TO BE USED FOR CONSTRUCTION,
BIDDING OR PERMIT PURPOSES
NOT FOR CONSTRUCTION
US Army Corps of
Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
F re e se a n d N ic h o ls
In c.
T e xa s
R e g is te re d E n g in e e ri n g
F ir m F
-2
C P
B
C P
B
D W
L
04/4/2019
VAN CASHEN P.E.
118595
M-001
L E
G E
N D
/4
/1
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F
R E
N O
V A
T
IO
N S
B L
D G
M A
R K
D E
S C
R
IP
T
IO
N D
A
1.1
4.4
B C D E F
G H J
3.5
2.5
A.8A.2
F.5F.7 G.7G.9F.9
4.7
4.3
1.2
2.3
3.7
GENERAL NOTES
1. REFER TO M-001 FOR LEGEND, GENERAL NOTES AND
ABBREVIATIONS.
2. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE
DEMOLISHED IN THEIR ENTIRETY. FOR EACH EQUIPMENT ITEM
TO BE DEMOLISHED, DEMOLISH ALL ASSOCIATED PIPING,
DUCTWORK, ACCESSORIES, WIRING AND CONTROLS.
3. EQUIPMENT LOCATIONS ARE APPROXIMATE.
A
C
KEY PLAN
B
PLAN NORTH
T H
IS
D
O C
U M
E N
T I
S R
E
LE
A S
E D
F O
R T
H
P U
R P
O S
E O
F I
N T
E R
IM
R
E V
IE
W
U N
D E
R T
T H
O R
IT
Y
O F
T E
X A
S N
O
N D
A T
E
IT
I
S N
O T
T O
B E
U S
E D
F O
R C
O N
S T
R U
C T
IO
N
B
ID
D
IN
G O
R P
E R
M
IT
P U
R P
O S
E S
N O
T F
O R
C O
N S
T R
U C
T
IO
N
US Army Corps of
Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
F re e se a n d N ic h o ls
In c.
T e xa s
R e g is te re d E n g in e e ri n g
F ir m F
-2
C P
B
C P
B
D W
L
/4
/2
V A
N C
A S
H E
N P
.E
MD-101
D E
M O
L
IT
IO
N
H V
A C
P L
A N
F
IR
S
T F
L O
O R
/4
/1
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F
R E
N O
V A
T
IO
N S
B L
D G
3/32" = 1'-0"
1 DEMO - FIRST FLOOR
NOTE BY SYMBOL " "
1. DEMOLISH CONDENSING UNIT.
2. DEMOLISH AIR HANDLER.
3. DEMOLISH HEATING VENTILATORS.
4. DEMOLISH EXHAUST FAN.
5. DEMOLISH VEHICLE EXHAUST SYSTEM.
0 8' 16'
3/32"=1'-0"
4'
1 1
1 1 1
M A
R K
D E
S C
R
IP
T
IO
N D
A
1.1
4.4
B C D E F
G H J
3.5
2.5
A.8A.2
F.5F.7 G.7G.9F.9
4.7
4.3
1.2
2.3
3.7
MAINTENANCE
AREA
COMBAT SPARES
CONSOLIDATED
BENCH REPAIR
FLUID DISTR
BREAK /
TRAINING
MENS
WOMENS
JAN
CORRIDOR
ADMIN SHOP
CONTROL
OFFICE 1
OFFICE 2
TOOL ROOM
NON-SENS
SECURE STOR
REPAIR AREA
ELEC
CU-7
CU-3
CU-4 CU-5CU-1
AHU-1
AHU-4
AHU-5
TO
AHU-5
TO
AHU-1 TO
AHU-4
HVU-1
HVU-4
CU-9
HVU-2
HVU-3
CU-6
AHU-6
EF-4
EF-5
EF-6
TO
AHU-6
CU-2
ARMS VAULT
COMSEC VAULT
120 CU-8
AHU-2
AHU-3
EF-1
EF-2
EF-3
EF-9
EF-10
EF-7 EF-8
UH-1
UH-3
DOAS-2
DOAS-1
TO
AHU-2
TO
AHU-3
GRH-1
GRH-2
GRH-3
GRH-4
GRH-5
GRH-6
GRH-7
GRH-8
VE-1
VE-2 VE-3
GRH-9 GRH-10 GRH-11
GRH-12
GRH-13
GRH-14
GRH-15
GRH-16
GRH-17
GRH-18GRH-19GRH-20
CO
NO
CO
NO
CO
NO
CO
NO
CO
NO
CO
NO
CO NO
CO NO
CO NO
CO NO
UH-2
UH-4
MECH
COMM 1
GENERAL NOTES
1. REFER TO M-001 FOR LEGEND, GENERAL NOTES AND
ABBREVIATIONS.
2. REFER TO DIVISION 23 FOR TECHNICAL SPECIFICATIONS.
3. REFER TO ELECTRICAL DRAWINGS FOR POWER
ROUTING/CONNECTION TO MECHANICAL EQUIPMENT.
4. INSTALL THERMOSTATS AT 48" AFF.
5. ALL MODEL NUMBERS CALLED OUT FOR VEHICLE EXHAUST SYSTEM
COMPONENTS ARE BASED ON CAR-MON PRODUCTS, INC.
6. PROVIDE FIRE RATED SLEEVES AND INTUMESCENT CAULK (ASTME
814 UL1479) FOR EVERY PENETRATION THROUGH A FIRE RATED
ENCLOSURE EQUAL TO THE RATING OF THE ENCLOSURE, IN
ACCORDANCE WITH THE MANUFACTURERS WRITTEN
INSTRUCTIONS.
7. CONTRACTOR SHALL WEATHERPROOF ALL ROOF AND EXTERIOR
WALL PENETRATIONS. REFER TO ARCHITECTURAL.
A
C
KEY PLAN
B
PLAN NORTH
T H
IS
D
O C
U M
E N
T I
S R
E
LE
A S
E D
F O
R T
P
R P
O S
E O
F I
N T
E R
IM
R
E V
IE
W
U N
D E
R T
T H
O R
IT
Y
O F
T E
X A
S N
N D
A T
E
IT
I
S N
O T
T O
B E
U S
E D
F O
R C
O N
S T
R U
C T
IO
N
B
ID
D
IN
G O
R P
E R
M
IT
P U
R P
O S
E S
N O
T F
O R
C O
N S
T R
U C
T
IO
N
US Army Corps of
Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
F re e se a n d N ic h o ls
In c.
T e xa s
R e g is te re d E n g in e e ri n g
F ir m F
-2
C P
B
C P
B
D W
L
/4
/2
V A
N C
A S
H E
N P
.E
M-101
F
IR
S T
F L O
O R
H V
A C
P L
A N
-O V
E R
A L
L
/4
/1
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F
R E
N O
V A
T
IO
N S
B L
D G
3/32" = 1'-0"
1 FIRST FLOOR HVAC PLAN - OVERALL
0 8' 16'
3/32"=1'-0"
4'
M A
R K
D E
S C
R
IP
T
IO
N D
A
TYPE D1 TYPE D2
FLOORING AS SCHED.
CEILING AS SCHED.
3 5/8" OR 4" MTL. STUDS DIAGONAL
BRACING @ 48" O.C. MAX., ALTERNATE
BRACES. MIN. ONE SET OF BRACES PER
EACH PARTITION.
BOTTOM OF
STRUCTURE OR
ROOF DECK
PLAN VIEW PLAN VIEW
5/8" GYPSUM WALL BOARD 5/8" GYPSUM WALL BOARD
WALL BASE AS SCHED.
TYPE D5
NEW OR EXIST. CONSTRUCTION
WHERE APPLICABLE
MTL. STUD TRACK W/ 2 1/2"
X 2 1/2" X 18 GA. MTL. ANGLE
U.N.O.
3"
PLAN VIEW
SECTION VIEW
5/8" GYPSUM WALL BOARD
METAL STUDS @ 16" O.C.
5/8" GYPSUM WALL BOARD
5/8" GYPSUM WALL BOARD
METAL STUDS @ 16" O.C.
5/8" GYPSUM WALL BOARD
5/8" GYPSUM WALL BOARD
METAL STUDS @ 16" O.C.
PLAN VIEW
SECTION VIEW
5/8" GYP. BD.
TILE ON 5/8" CEMENTITIOUS BACKER
BD. ON MTL. STUDS AT 16" O.C. - USE
5/8" GYP. BD. ABOVE TILE
TILE ON 5/8" CEMENTITIOUS BACKER BD.
ON MTL. STUDS AT 16" O.C. - USE WATER
RESISTANT GYP. BD. ABOVE TILE
5/8" GYP. BD.
OMIT GYP. BD. @ CHASE SIDE
WHERE APPLICABLE
TYPE T1
SECTION VIEWSECTION VIEW
CONTRACTOR OPTION TO
EXTEND STUDS TO STRUCTURE
AND ELIMINATE BRACING - PROVIDE SLIP JOINT
FLOORING AS SCHED.
WALL BASE AS SCHED.
CONT. AC SEALANT @ EACH LAYER
OF GYP. BD.
METAL STUDS @ 16" O.C.
SOUND ATTENUATION FULL HEIGHT
METAL STUDS @ 16" O.C.
NOTE:
OMIT GYP. BD. @ CHASE SIDE
WHERE APPLICABLE
CEILING AS SCHED.
CONT. AC SEALANT @ EACH LAYER
OF GYP. BD.
5/8" GYPSUM WALL BOARD
FLOORING AS SCHED.
WALL BASE AS SCHED.
METAL STUDS @ 16" O.C.
CEILING AS SCHED. CEILING AS SCHED.
3 5/8" OR 4" MTL. STUDS DIAGONAL
BRACING @ 48" O.C. MAX., ALTERNATE
BRACES. MIN. ONE SET OF BRACES PER
EACH PARTITION.
CONTRACTOR OPTION TO
EXTEND STUDS TO STRUCTURE
AND ELIMINATE BRACING - PROVIDE SLIP JOINT
FLOORING AS SCHED.
WALL BASE AS SCHED.
NOTE:
OMIT GYP. BD. @ CHASE SIDE WHERE
APPLICABLE
PROVIDE SLIP JOINT REFER TO
TYPICAL DEFLECTION TRACK
DETAILS
BOTTOM OF
STRUCTURE OR
ROOF DECK
PLAN VIEW
SECTION VIEW
5/8" GYP. BD.
TYPE T2
FLOORING AS SCHED.
WALL BASE AS SCHED.
CONT. AC SEALANT @ EACH LAYER
OF GYP. BD.
SOUND ATTENUATION FULL HEIGHT
CEILING AS SCHED.
CONT. AC SEALANT @ EACH LAYER
OF GYP. BD.
PROVIDE SLIP JOINT REFER TO
TYPICAL DEFLECTION TRACK
DETAILS
TILE ON 5/8" CEMENTITIOUS BACKER
BD. ON MTL. STUDS AT 16" O.C. - USE
5/8" GYP. BD. ABOVE TILE
TYPE M2
CEILING
AS SCHEDULED
T.O.M.
8" CMU (GROUT FILLED AT M2A)
GYP.BD MTL STUD PARTITION ABOVE
SECTION VIEW
BOTTOM OF
STRUCTURE OR
ROOF DECK
3 LAYERS 5/8" ABUSE RESIST. GYP. BD.
ON 6" MTL STUDS @ 16" O.C. W/ SOUND
ATTENUATION FULL HEIGHT ( ALIGN ONE
SIDE W/ FACE OF CMU)
PLAN VIEW
FLOORING AS SCHED.
WALL BASE AS SCHED.
8" CMU (GROUT FILLED AT M2A)
9' - 4" AFF
U .O
.N
TILE ON 5/8" CEMENTITIOUS BACKER BD.
ON MTL. STUDS AT 16" O.C. - USE WATER
RESISTANT GYP. BD. ABOVE TILE
5/8" GYP. BD.
OMIT GYP. BD. @ CHASE SIDE
WHERE APPLICABLE
CONT. AC SEALANT @ EACH LAYER
OF GYP. BD., TOP AND BOTTOM
PROVIDE SLIP JOINT REFER TO
TYPICAL DEFLECTION TRACK
DETAILS
TYPE M3
CEILING
AS SCHEDULED
T.O.M.
8" CMU
GYP.BD MTL STUD PARTITION ABOVE
SECTION VIEW
BOTTOM OF
STRUCTURE OR
ROOF DECK
3 LAYERS 5/8" ABUSE RESIST. GYP. BD.
ON 6" MTL STUDS @ 16" O.C. W/ SOUND
ATTENUATION FULL HEIGHT ( ALIGN ONE
SIDE W/ FACE OF CMU)
PLAN VIEW
FLOORING AS SCHED.
WALL BASE AS SCHED.
8" CMU
9' - 4" AFF
CONT. AC SEALANT @ EACH LAYER
OF GYP. BD.
PROVIDE SLIP JOINT REFER TO
TYPICAL DEFLECTION TRACK
DETAILS
EXPANDED MTL LATH BEHIND ONE
LAYER OF GWB
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
FOR INTERIM REVIEW
ONLY, NOT FOR
CONSTRUCTION
TROY C. SECORD
TEXAS REGESTRATION
NO. 12994 A-601
P A
R T
IT
IO
N T
Y P
E S
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
T C
S
M P
T
D R
R
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
D1 PARTITIONS
TYPE
FIRE
RATING
STUD
SIZE DESCRIPTION STC
D1 - 3 5/8" AS SHOWN -
D2 PARTITIONS
TYPE
FIRE
RATING
STUD
SIZE DESCRIPTION STC
D2 - 3 5/8" AS SHOWN 45
D2A - 6" AS SHOWN 45
D5 PARTITIONS
TYPE
FIRE
RATING
STUD
SIZE DESCRIPTION STC
D5 - 2 1/2" AS SHOWN -
T1 PARTITIONS
TYPE
FIRE
RATING
STUD
SIZE DESCRIPTION STC
T1 - 3 5/8" AS SHOWN -
T2 PARTITIONS
TYPE
FIRE
RATING
STUD
SIZE DESCRIPTION STC
T2 - 3 5/8" 45
M2 PARTITIONS
TYPE
FIRE
RATING DESCRIPTION STC
M2 - AS SHOWN 45
M2A - AS SHOWN 50
M2B 2 HR SAME AS M2 EXCEPT W/ 2 LAYERS
GYP. BD. EACH SIDE OF MTL STUDS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
M3 PARTITIONS
TYPE
FIRE
RATING DESCRIPTION STC
M3 - AS SHOWN 45
FLUSH
F
AS SCHED.
A S
S C
H E
D
NARROW LITE
NL
AS SCHED.
A S
S C
H E
D
10" 8"
M A
X
A S
S C
H E
D
AS SCHED.
OVERHEAD COILING DOOR
OH
GLAZING
AS SCHED.
CLASS 5 ARMORY VAULT DOOR & DAY GATE
AV
AS SCHED.
11" 1' - 2"
11"
A S
S C
H E
D
AS SCHED.
COUNTER SHUTTER
OH 2
AS SCHED.
FIN. FLR.
HOLLOW METAL FRAME
H2
W/ 1/2" BACKBEND
A S
S C
H E
D
2" AS SCHED. 2"
PROFILE
VARIES
1/2" 1/2"
1 15/16"1 15/16"
/8
HOLLOW METAL FRAME
H1
W/ 1/2" BACKBEND
A S
S C
H E
D
2" AS SCHED. 2"
PROFILE
VARIES
1/2" 1/2"
1 15/16"1 15/16"
/8
HOLLOW METAL FRAME
H3
W/ 1/2" BACKBEND
A S
S C
H E
D
2" AS SCHED. 2"
1' - 4"
2"
PROFILE
VARIES
1/2" 1/2"
1 15/16"1 15/16"
/8
A
HORIZONTAL SLIDER
B
FIXED
F.F.
5' - 0"
F.F.
5' - 0"
DOOR SCHEDULE NOTES
1. SEE FLOOR PLANS FOR DOOR LOCATIONS AND SWINGS.
2. PROVIDE SEALANT AROUND FULL PERIMETER OF FRAMES, BOTH
SIDES OF PARTITIONS, ETC.
3. VAULT DOOR HARDWARE PROVIDED BY VAULT DOOR
MANUFACTURER. DOORS SHALL BE SUPPLIED WITH GSA APPROVED
COMBINATION LOCKS (KABA MAS OR EQUAL) COMPLIANT WITH
CURRENT UNIFIED FEDERAL GUIDE SPECIFICATIONS (UFGS)
STANDARDS APPROPRIATE FOR VAULT DOOR TYPE.
4. EXTERIOR OVERHEAD COILING DOORS TO BE ELECTRICALLY
OPERATED WITH THE CAPABILITY OF LOCKING DOOR OPEN AT 1’-0”
A.F.F.
5. NO THRESHOLD / TRANSITION REQUIRED AT DOORWAYS IN SPACES
HAVING THE SAME FLOOR FINISH ON BOTH SIDES OF THE DOOR.
SPACES HAVING DIFFERENT FLOOR FINISHES WILL REQUIRE
TRANSITION.
DOOR SCHED. ABB
GLZ GLAZING
HM HOLLOW METAL
STL STEEL
WD WOOD
GLAZING SCHEDULE
FG-1 1/4" (6mm) CLEAR (FULLY TEMPERED) GLASS
IG-1 1" INSULATED - TINTED GLASS UNIT LOW- E WITH/ .030 PVB
LSG-1 1/4" LAMINATED SAFETY GLASS WITH / .030 PVB
COMMENTS
1. PAIR OF DOORS
2. CLASS 5 VAULT DOOR WITH DAY GATE, INSTALL PER
MANUFACTURER’S STANDARD DETAILS
a. ARMS VAULT TO RECEIVE CLASS 5A VAULT DOOR
b. COMSEC VAULT TO RECEIVE CLASS 5V VAULT DOOR
c. DAY GATE: STL MESH, DEADBOLT OUTSIDE WITH THUMB
LATCH INSIDE
3. OVERHEAD DOOR HARDWARE & GUIDES/FRAME ASSEMBLY PER DOOR
MANUFACTURER.
4. INTERIOR DOOR FINISH TO MATCH EXTERIOR.
5. SECURITY DOOR COMPLYING WITH SECURE ROOM STANDARDS OF AR
380-5. 16 GA (MIN.) HOLLOW METAL DOOR WITH NON-REMOVABLE PIN
HINGES. PROVIDE LOCKMASTERS LKM 7000 SINGLE MOTION LIFE
SAFETY EXIT DEVICE MEETING FF-L-2890A (TYPE IV) WITH DIAL-TYPE
ELECTRO-MECHANICAL COMBINATION LOCK MEETING FF-L-2740A.
6. PROVIDE PAD-LOCKABLE SLIDING BOLTS ON INTERIOR OF MANUALLY
OPERATED OVERHEAD COILING DOORS EACH JAMB.
7. PROVIDE 14” X 14” LOUVERS IN EACH LEAF.
8. PAINT EXISTING DOOR AND FRAME.
9. PROVIDE NEW HARDWARE SET AS NOTED.
10. BASIS OF DESIGN FOR COUNTERTOP DOOR IS CORNELL SOUND
BARRIER DOOR UTILIZING URETHANE-FOAM FILLED METAL SLATS &
PERIMETER SEALS.
11. RE-KEY EXISTING DOOR HARDWARE TO MATCH NEW.
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
FOR INTERIM REVIEW
ONLY, NOT FOR
CONSTRUCTION
TROY C. SECORD
TEXAS REGESTRATION
NO. 12994 A-602
S C
H E
D U
L E
S
D O
O R
A N
D W
IN
D
O W
T Y
P E
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
T C
S
M P
T
D R
R
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
DOOR SCHEDULE
DOOR NO. TYPE
DOOR
FIRE
RATING
FRAME
HARDWAR
E COMMENTS:
SIZE
MATERIAL FINISH
GLAZIN
G TYPE MATERIAL FINISH GLAZING
DETAILS
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
101.1 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
101.2 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
102 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT FG-1 - H2 HM PT D1/A-604 B1/A-604 A1/A-603 HW - 6
103 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H3 HM PT FG-1 D1/A-603 B1/A-603 A1/A-603 HW - 7
104 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H3 HM PT FG-1 D1/A-603 B1/A-603 A1/A-603 HW - 7
105 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D3/A-603 B3/A-603 A3/A-603 HW - 11
106 F 5' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D3/A-603 B3/A-603 A3/A-603 HW - 1 NOTE 1, 7
107 F 6' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D3/A-603 B3/A-603 A3/A-603 HW - 1 NOTE 1, 7
108 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
109 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 10 NOTE 5
110 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 4
111 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 5
112 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 5
113 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT FG-1 - H2 HM PT D1/A-604 B1/A-604 A1/A-603 HW - 6
114 F 6' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 1 NOTE 1, 7
115 F 6' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 3 NOTE 1
116 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H2 HM PT D4/A-603 B4/A-603 A1/A-603 HW - 8
117.1 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
117.2 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
117.3 EXIST 3' - 0" 7' - 0" 1 3/4"
118.1 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
118.2 EXIST 3' - 0" 7' - 0" 1 3/4" NOTE 8,11
118.3 EXIST 3' - 0" 7' - 0" 1 3/4"
119 AV 3' - 0" 7' - 0" 1 3/4" STL PT - - - STL PT NOTE 2
120 AV 3' - 0" 7' - 0" 1 3/4" STL PT - - - STL PT NOTE 2
201.1 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT LSG-1- - H1 HM PT D2/A-603 B2/A-603 A1/A-603 HW - 2
201.2 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT LSG-1- - H1 HM PT D2/A-603 B2/A-603 A1/A-603 HW - 2
202 F 3' - 0" 7' - 0" 1 3/4" HM PT - - H1 HM PT D1/A-603 B1/A-603 A1/A-603 HW - 6
203 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT FG-1 - H1 HM PT D1/A-603 B1/A-603 A1/A-603 HW - 6
204.1 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT FG-1 - H1 HM PT D1/A-603 B1/A-603 A1/A-603 HW - 9
204.2 NL 3' - 0" 7' - 0" 1 3/4" HM / GL PT FG-1 - H1 HM PT D1/A-603 B1/A-603 A1/A-603 HW - 9
OH102 OH2 3' - 0" 4' - 4" D2/A-605 B2/A-605 A2/A-605 NOTE 6, 10
OH108.1 OH 10' - 0" 10' - 0" 3" STL PT - - - STL PT D3/A-604 B3/A-604 A3/A-604 NOTE 6
OH108.2 OH2 3' - 0" 4' - 4" D1/A-605 B1/A-605 A1/A-605 NOTE 6, 10
OH115.1 OH 10' - 0" 9' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 6
OH115.2 OH2 3' - 0" 4' - 4" D2/A-604 B2/A-604 A2/A-604 NOTE 6, 10
OH116 OH 10' - 0" 9' - 0" 3" STL PT - - - STL PT D3/A-604 B3/A-604 A3/A-604 NOTE 3,6
OH117.1 OH 14' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
OH117.2 OH 14' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
OH117.3 OH 14' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604
OH118.1 OH 14' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
OH118.2 OH 24' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
OH118.3 OH 16' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
OH118.4 OH 14' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
OH118.5 OH 24' - 0" 16' - 0" 3" STL PT - - - STL PT D4/A-604 B4, B3/A-604 A3/A-604 NOTE 3,4
WINDOW SCHEDULE
Mark
R.O.
Type
FRAME GLAZING DETAILS
Head Height Remarks (See Notes Below)Width Height Finish Material Type Thickness Head Jamb
Window _Sill
A 5' - 0" 3' - 0" HORIZONTAL SLIDING DB AL IG-1 1" D2/A-606 A2/A-606 B2/A-606 7' - 4"
B 5' - 0" 3' - 0" WINDOW FIXED DB AL IG-1 1" D1/A-606 B1/A-606 A1/A-606 7' - 4"
B.1 5' - 0" 3' - 0" WINDOW FIXED DB AL IG-1 1" D4/A-606 B4/A-606 A4/A-606 7' - 4"
1/4" = 1'-0"A-602
A1 DOOR TYPES
1/4" = 1'-0"A-602
A2 FRAME TYPES
1/4" = 1'-0"A-602
B1 WINDOW TYPES
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
0' 4' 8'
GRAPHIC SCALE 1/4" = 1'-0"
2'1'
| Drawing ( Tech Exh B) 61 |
| Drawing ( Tech Exh B) 62 |
| Drawing ( Tech Exh B) 63 |
| Drawing ( Tech Exh B) 64 |
| Drawing ( Tech Exh B) 65 |
| Drawing ( Tech Exh B) 66 |
| Drawing ( Tech Exh B) 67 |
| Drawing ( Tech Exh B) 68 |
| Drawing ( Tech Exh B) 69 |
| Drawing ( Tech Exh B) 70 |
| Drawing ( Tech Exh B) 71 |
| Drawing ( Tech Exh B) 72 |
File details come from the government source that posted it.