Drawing_25-36_pages.pdf
PDF 2 MB Posted
- Attached to
- Renovation of TEMP Bldg 26041
- Solicitation number
- W91151-19-B-0016
About this file
Drawing pages 25-36
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B C D E F G.9 JG.7
1.11.1
F.5 H
2.3
2.5
3.5
4.4
4.7
3.7
F.7 F.9
1.2
4.3
A BA.8A.2
G
LOW ROOF BELOW
OPEN ROOF BELOW
OPEN ROOF BELOW
LEGEND
S
3/S-204
2/S-204
P A
R T
I T
I O
N
A
S S
E M
B L
Y
B
Y
O
T H
E R
S
W12x14
W x
W x
W12x14
W12x14
W x
W x
W12x14
S
EXIST'G FRAME
TO BE REMOVED
EXIST'G FRAME
TO BE REMOVED
NEW FRAME TO
BE ADDED
NEW FRAME TO
BE ADDED
N E
W
F
R A
M E
L O
W
N E
W
F
R A
H
I G
H
N E
W
F
R A
I G
H
TOS EL. 25'-0"
TOS EL. 25'-0"
EXISTING MANUF. BLDG.
TO REMAIN
NEW 4" STUD WALL
NEW 6" STUD WALL
TOP OF STEEL = VARIES UNLESS
(T.O.S.) NOTED OTHERWISE
W x
C x
W x x
Sheet
Reference
Number:
ofSheet
A
B
C
D a t e
A p p r o v a l D e s c r i p t i o n S y m b o l
P l o t
S c a l e
D a t e
F i l e n a m e
D a t e
D r a w n
B y
S C
R e v i e w e d
B y
S u b m i t t e d
B y
K e n a l l F
N I
C h e c k e d
B y
D R
W
P l o t
D a t e
D e s i g n e d
B y
D R
W
S o l i c i t a t i o n
N o
US Army Corps of Engineers
Fort Worth District
D E
S I G
N
O
F
T
E M
F
R
E N
O V
A T
I O
N S
F O
R T
O O
D
T
E X
A S
B L
D G
P r o j e c t
N o
W
G
D
R E
V I S
I O
N S
In te rn at io na l P la za
Su ite
Fo rt
W or th , T ex as
-4
Ph on e
7)
-7
Fa x
7)
-7
N O
T
F
N
S T
R U
C T
I O
N
T H
I S
C
U M
E N
T
L E
A S
F
E
P U
R P
O S
E
O
F
I N
T E
R
V
I E
W
U
N D
E
A U
T H
O R
I T
Y
O
F
D
A Y
A
D
A Y
A N
D A
N D
A
P
E
T E
X A
S
N
O
N
D
A T
E
B
E
U
S E
D
F
N
S T
R U
C T
I O
N
B I D
D I N
G
O
R
P
E R
M
P
U R
P O
S E
S
K e n a l l
C o n s u l t i n g
E n g i n e e r s
I n c
T e x a s
R e g i s t e r e d
E n g i n e e r i n g
F i r m e e s e a n d
N i c h o l s
I n c x a s
R e g i s t e r e d
E n g i n e e r i n g
F i
S
U B
M I T
T A
L
S
E T
S T
R U
C T
U R
A L
C
E I L
I N
G
F R
A M
I N
G
B
U I L D
I N
G
S-103
CEILING FRAMING - OVERALL
0 4 8 16
3/32" = 1'-0" (24"x36") 3/64" = 1'-0" (11"x17")
SCALE:
GRID
Sheet
Reference
Number:
ofSheet
A
B
C
D a t e
A p p r o v a l D e s c r i p t i o n S y m b o l
P l o t
S c a l e
D a t e
F i l e n a m e
D a t
D r a
S C
R e v i e w e d
B y
S u b m i t t e d
B y
K e n a l l F
N I
C h e c k e d
B y
D R
W
P l o t
D a t e
D e s i g n e d
B y
D R
W
S o l i c i t a t i o n
N o
US Army Corps of Engineers
Fort Worth District
D E
S I G
N
O
F
T
E M
F
R
E N
O V
A T
I O
N S
F O
O
D
T
E X
A S
B L
R E
V I S
I O
N S
In te rn at io na l P la za
Su ite
Fo rt
W or th , T ex as
-4
Ph on e
7)
-7
Fa x
7)
-7
N O
T
F
N
S T
R U
C T
I O
N
T H
C
U M
E N
T
L E
A S
E
P U
R P
O S
E
O
F
I N
T E
R
V
I E
W
U
N D
E
A U
T H
O R
I T
Y
O
F
D
A Y
A
D
A Y
A N
D A
N D
A
P
E
T E
X A
S
N
O
D
A T
E
B
E
U
S E
D
F
N
S T
R U
C T
I O
N
B I D
D I N
G
O
R
P
E R
M
R
P O
S E
S
K e n a l l
C o n s u l t i n g
E n g i n e e r s
I n c
T e x a s
R e g i s t e r e d
E n g i n e e r i n g
F i e e s e a n d
N i c h o l s
I n x a s
R e g i s t e r e d
E n g i n e e r i n g
F i
S
U B
M I T
T A
L
S
E T
S-201
F O
U N
D A
T I O
N
S
E C
T I O
U I L D
I N
G
Reference
Number:
ofSheet
A
B
C
D a t e
A p p r o v a l D e s c r i p t i o n S y m b o l
P l o t
S c a l e
D a t e
F i l e n a m e
D a t
D r a
S C
R e v i e w e d
B y
S u b m i t t e d
B y
K e n a l l F
N I
C h e c k e d
B y
D R
W
P l o t
D a t e
D e s i g n e d
B y
D R
W
S o l i c i t a t i o n
N o
US Army Corps of Engineers
Fort Worth District
D E
S I G
N
O
F
T
E M
F
R
E N
O V
A T
I O
N S
F O
O
D
T
E X
A S
B L
P r o j e c t
N o
W
G
D
R E
V I S
I O
N S
In te rn at io na l P la za
Su ite
Fo rt
W or th , T ex as
-4
Ph on e
7)
-7
Fa x
7)
-7
N O
T
F
N
S T
R U
C T
I O
N
T H
C
U M
E N
T
L E
A S
E
P U
R P
O S
E
O
F
I N
T E
R
V
I E
W
U
N D
E
A U
T H
O R
I T
Y
O
F
D
A Y
A
D
A Y
A N
D A
N D
A
P
E
T E
X A
S
N
O
D
A T
E
B
E
U
S E
D
F
N
S T
R U
C T
I O
N
B I D
D I N
G
O
R
P
E R
M
R
P O
S E
S
K e n a l l
C o n s u l t i n g
E n g i n e e r s
I n c
T e x a s
R e g i s t e r e d
E n g i n e e r i n g
F i e e s e a n d
N i c h o l s
I n x a s
R e g i s t e r e d
E n g i n e e r i n g
F i
S
U B
M I T
T A
L
S
E T
S-202
F O
U N
D A
T I O
N
S
E C
T I O
U I L D
I N
G
Reference
Number:
ofSheet
A
B
C
D a t e
A p p r o v a l D e s c r i p t i o n S y m b o l
P l o t
S c a l e
D a t e
F i l e n a m e
D a t
D r a
S C
R e v i e w e d
B y
S u b m i t t e d
B y
K e n a l l F
N I
C h e c k e d
B y
D R
W
P l o t
D a t e
D e s i g n e d
B y
D R
W
S o l i c i t a t i o n
N o
US Army Corps of Engineers
Fort Worth District
D E
S I G
N
O
F
T
E M
F
R
E N
O V
A T
I O
N S
F O
O
D
T
E X
A S
B L
P r o j e c t
N o
W
G
D
R E
V I S
I O
N S
In te rn at io na l P la za
Su ite
Fo rt
W or th , T ex as
-4
Ph on e
7)
-7
Fa x
7)
-7
N O
T
F
N
S T
R U
C T
I O
N
T H
C
U M
E N
T
L E
A S
E
P U
R P
O S
E
O
F
I N
T E
R
V
I E
W
U
N D
E
A U
T H
O R
I T
Y
O
F
D
A Y
A
D
A Y
A N
D A
N D
A
P
E
T E
X A
S
N
O
D
A T
E
B
E
U
S E
D
F
N
S T
R U
C T
I O
N
B I D
D I N
G
O
R
P
E R
M
R
P O
S E
S
K e n a l l
C o n s u l t i n g
E n g i n e e r s
I n c
T e x a s
R e g i s t e r e d
E n g i n e e r i n g
F i e e s e a n d
N i c h o l s
I n x a s
R e g i s t e r e d
E n g i n e e r i n g
F i
S
U B
M I T
T A
L
S
E T
S-203
F R
A M
I N
G
S
E C
T I O
U I L D
I N
G
G.9 G.7H
GRID
F.9F.7F.5
Sheet
Reference
Number:
ofSheet
A
B
C
D a t e
A p p r o v a l D e s c r i p t i o n S y m b o l
P l o t
S c a l e
D a t e
F i l e n a m e
D a t
D r a
S C
R e v i e w e d
B y
S u b m i t t e d
B y
K e n a l l F
N I
C h e c k e d
B y
D R
W
P l o t
D a t e
D e s i g n e d
B y
D R
W
S o l i c i t a t i o n
N o
US Army Corps of Engineers
Fort Worth District
D E
S I G
N
O
F
T
E M
F
R
E N
O V
A T
I O
N S
F O
O
D
T
E X
A S
B L
P r o j e c t
N o
W
G
D
R E
V I S
I O
N S
In te rn at io na l P la za
Su ite
Fo rt
W or th , T ex as
-4
Ph on e
7)
-7
Fa x
7)
-7
N O
T
F
N
S T
R U
C T
I O
N
T H
C
U M
E N
T
L E
A S
E
P U
R P
O S
E
O
F
I N
T E
R
V
I E
W
U
N D
E
A U
T H
O R
I T
Y
O
F
D
A Y
A
D
A Y
A N
D A
N D
A
P
E
T E
X A
S
N
O
D
A T
E
B
E
U
S E
D
F
N
S T
R U
C T
I O
N
B I D
D I N
G
O
R
P
E R
M
R
P O
S E
S
K e n a l l
C o n s u l t i n g
E n g i n e e r s
I n c
T e x a s
R e g i s t e r e d
E n g i n e e r i n g
F i e e s e a n d
N i c h o l s
I n x a s
R e g i s t e r e d
E n g i n e e r i n g
F i
S
U B
M I T
T A
L
S
E T
S-204
F R
A M
I N
G
S
E C
T I O
U I L D
I N
G
A4/S-301
A3/S-301
A2/S-301
A1/S-301
A4/S-301
A3/S-301
A2/S-301
A1/S-301
3d/S-301
3c/S-301
3d/S-301
3a/S-301
1/S-301 1/S-301
1/S-3011/S-301
S
Sheet
Reference
Number:
ofSheet
A
B
C
D a t e
A p p r o v a l D e s c r i p t i o n S y m b o l
P l o t
S c a l e
D a t e
F i l e n a m e
D a t
D r a
S C
R e v i e w e d
B y
S u b m i t t e d
B y
K e n a l l F
N I
C h e c k e d
B y
D R
W
P l o t
D a t e
D e s i g n e d
B y
D R
W
S o l i c i t a t i o n
N o
US Army Corps of Engineers
Fort Worth District
D E
S I G
N
O
F
T
E M
F
R
E N
O V
A T
I O
N S
F O
O
D
T
E X
A S
B L
P r o j e c t
N o
W
G
D
R E
V I S
I O
N S
In te rn at io na l P la za
Su ite
Fo rt
W or th , T ex as
-4
Ph on e
7)
-7
Fa x
7)
-7
N O
T
F
N
S T
R U
C T
I O
N
T H
C
U M
E N
T
L E
A S
E
P U
R P
O S
E
O
F
I N
T E
R
V
I E
W
U
N D
E
A U
T H
O R
I T
Y
O
F
D
A Y
A
D
A Y
A N
D A
N D
A
P
E
T E
X A
S
N
O
D
A T
E
B
E
U
S E
D
F
N
S T
R U
C T
I O
N
B I D
D I N
G
O
R
P
E R
M
R
P O
S E
S
K e n a l l
C o n s u l t i n g
E n g i n e e r s
I n c
T e x a s
R e g i s t e r e d
E n g i n e e r i n g
F i e e s e a n d
N i c h o l s
I n x a s
R e g i s t e r e d
E n g i n e e r i n g
F i
S
U B
M I T
T A
L
S
E T
S-301
H O
U S
E
R
E E
L
F
R A
U I L D
I N
G
P
E
N I N
G
44'-0"
1'-0" 1'-0"
40'-0" (PIT OPENING)
25'-0" 7'-6"
2'-0" 1'-0" 1'-0"
7'-6"
8 1/4"
R
8 1/4"
DOWN
R
44'-0"
8'-0"3'-0"6'-0"8'-0"
1'-0" 16'-0" 10'-0"
8'-0" 17'-0"
16'-0" 1'-0"
2'-0"2'-6"4'-0"2'-6"2'-0"1'-6"4'-0" 13'-6"8'-0"
CONT. GALV. L4x3x1/4
LLV AROUND PERIMETER
PROVIDE (1)#5 x 48" LONG AT TOP
AND BOTTOM OF SLAB AT ALL
RE-ENTRANT CORNERS. (TYP.)
4" CONC. CURB AT EACH
END OF PIT (TYP.)
DOWN
INSIDE FACE OF
WALL
NOTE: GRATING AT TOP OF
MAINTENANCE PIT IS NOT
SHOWN FOR CLARITY
HIDDEN LINES WITHIN PIT WALLS DENOTE EXTENTS OF
HOSE REEL, TOOL AND LIGHT SHELF AND OIL EVACUATION
PIT RECESSES. SEE OTHER DETAILS ON THIS SHEET FOR
MORE INFORMATION (TYP.)
MAINTENANCE PIT
FOUNDATION REINFORCED
WITH #6 @ 12"o.c. E.W. T&B
24"x24"x18"(DEEP)
SUMP PIT
DENOTES 22" THICK WALL
AT SIDE OF PIT (TYP.)
3'-0"2'-0"18'-6" 2'-0" 18'-6"
2" CLR
TYP
1" CLR
TYP
4" THICK CAST IN PLACE
CONCRETE CURB AT EACH
END OF PIT REINF. WITH
6x6-W2.0xW2.0 WELDED
WIRE CENTERED IN SLAB.
(TYP)
CONT. GALV. L4x3x1/4 LLV
AROUND PERIMETER. (TYP.)
FLOOR GRATING SUPPORT ANGLE
WITH POST INSTALLED ANCHORS
-SEE DETAIL 5 & 6 THIS SHEET FOR
MORE INFORMATION.
(3) #6 "U" BARS EACH WAY
1/2" DIA.x3" LONG HEADED STUD ANCHORS
WELDED TO PERIMETER ANGLE @ 12"o.c.
(TYP.)
(1)#5 x 48" LONG E.F. A EACH CORNER
OF WALL RECESS. PROVIDE #5 x 2'-9"
WITH 90 DEGREE STD. HOOK WHERE
PIT GEOMETRY PREVENTS STRAIGHT
BARS (TYP.)
2'-0"
14'-0"2'-0"2'-0"2'-0"2'-0"2'-0"4'-0"8'-0"1'-0" 1'-0"
1'-6" 1'-0" 1'-6"
LIGHT
RECESS
OIL
EVAC
RECESS
1'-6" 1'-0" 1'-6"
HOSE REEL RECESS AT THIS SIDE OF PIT. SEE
DETAIL 6 ON THIS SHEET FOR DIMENSIONAL
INFORMATION. COORDINATED LOCATION WITH
MEP DWGS.
RIDGID INSULATION UNDER SLAB ON
GRADE AND BEHIND PIT WALL-SEE
ARCH FOR DETAILS. (TYP.)
CONT. WATERPROOF MEMBRANE.
(TYP)
CONT. BULB-TYPE WATERSTOP.
(TYP)
CONT. 2X6 SHEAR KEY (TYP)
MAINTANCE PIT FOUNDATION
- REINFORCED WITH #6 @
12"o.c. E.W., T&B
SLOPE SLOPE
SLOPE TOP OF PIT FOUNDATION
SLAB TO SUMP PIT. (TYP)
LIGHT AND OIL EVACUATION
RECESSES ON EACH SIDE OF HOSE
REEL RECESS AT THIS SIDE OF PIT.
SEE DETAILS 5 &6 ON THIS SHEET FOR
DIMENSIONAL INFORMATION. (TYP)
20'-0" 20'-0"
2'-0"2'-0"
LIGHT
RECESS
L4x3x1/4x0'-6" (LLV) WITH 1/2" DIA.
X 5" LONG POST INSTALLED
ANCHORS WITH LEVELING BED OF
NON-SHRINK GROUT. (TYP)
C
L R
T Y
P
1"
TYP
GALVANIZED L2x2x1/4 STAIR
TREAD SUPPORT BRACKET. (TYP)
GALVANIZED 12" DEEP STEEL CHANNEL
STRINGER BY STAIR SUPPLIER. (TYP)
3/16
FIN. FLOOR
0'-0"
S
1'-0"
12" WIDE END PIT WALLS REINFORCED
- WITH #6 VERTICALS @ 18"o.c. EF AND
#6 HORIZONTAL BARS @ 12"o.c. EF
1'-0"
(3) #4 TIES
T.O. PIT FTG
-5'-0"
S
℄ SUMP PIT 4
S
FRENCH DRAIN AROUND
PERIMETER OF PIT WALL.
SEE CIVIL (TYP)
SUMP PIT FOUNDATION.
COORDINATE LOCATION
WITH MEP DWGS.
3'-0"2'-0"18'-6" 2'-0" 18'-6"
2" CLR
TYP
CONT. 3/8" THICK X 6" WIDE PLATE
SHOP FILLET WELDED TO EMBED
PLATE AT TOP AND BOTTOM. (TYP)
CONT. 3/8" THICK BENT PLATE (7"V X 3"H)
WITH 2 ROWS (1 ROW DIAGONAL) OF 1/2"
DIA. x 4" LONG HEADED STUD ANCHORS
SHOP WELDED TO PLATE @ 12"o.c. MIN
(1)#4 HORIZ AT EACH ROW OF STUDS. (TYP)
2'-0"
7'-6"7'-6"1'-0" 1'-0"
EXISTING CONC SLAB REPLACE AS
REQUIRED MATCH EXISTING CONC.
SLAB THICKNESS AND STEEL SIZE
AND REINFORCEMENT SPACING (TYP)
SLOPE SLOPE
BENT BARS AT SUMP PIT SHALL
MATCH SIZE AND SPACING OF
FOUNDTION REINFORCING IN
EACH DIRECTIONS
20'-0" 20'-0"
25'-0"
LIGHT
RECESS
C
L R
T Y
P
T.O. PIT FTG
-5'-0"
FIN. FLOOR
0'-0"
S
S
S
TYP
1" CLR
REMOVABLE CORRUGATED METAL
GRATING TO HAVE NON-SLIP AND
ANTI-SPARK FINISH (TYP)
1'-0"1'-0"
1/2" DIA.x3" LONG HEADED STUD ANCHORS
WELDED TO PERIMETER ANGLE @ 12"o.c.
(TYP.)
(1)#5 x 48" LONG E.F. A EACH CORNER
OF WALL RECESS. PROVIDE #5 x 2'-9"
WITH 90 DEGREE STD. HOOK WHERE
PIT GEOMETRY PREVENTS STRAIGHT
BARS (TYP.)
REMOVABLE CORRUGATED METAL GRATING TO HAVE
NON-SLIP AND ANTI-SPARK FINISH AT TOP AND BOTTOM OF
PIT. GRATING SHALL CONSIST OF 1 1/4"x3 /16" BEARING BAR
@ 1 3/16"o.c. AND WELDED CROSS BAR @ 4"o.c.
CONT. LIGHT AND TOOL SHELF RECESS AT THIS
SIDE OF PIT. SEE DETAIL 5 ON THIS SHEET FOR
DIMENSIONAL INFORMATION℄ SUMP PIT
9'-2"
FIN. FLOOR
0'-0"
1'-0"1'-0"
T.O. PIT FTG
-5'-0"
REMOVABLE CORRUGATED METAL
STAIR TREADS WITH NON-SLIP AND
ANTI-SPARK FINISH. STAIR TREAD
SHALL CONSIST OF 1 1/4"x3 /16"
BEARING BAR @ 1 3/16"o.c. AND
WELDED CROSS BAR @ 4"o.c. WITH
CHECKERED PLATE NOSING. (TYP)
GRACO 218969 30 GALLON ROLLING
DRAIN CART (SPECIFIED WITH POL
EQUIPMENT
W14x26 ROLLER SUPPORT BEAM
CONT. GALV. L4x3x1/4 LLV AROUND
PERIMETER SUPPORTING FLOOR
GRATING
22" WIDE END PIT WALLS
REINFORCED - WITH #6
VERTICALS @ 18"o.c. EF
AND #6 HORIZONTAL BARS
@ 12"o.c. EF
1'-10"
3"
3'-6"
℄ PIT
1'-10"
3"
7'-2"
C
L R
T Y
P
FRENCH DRAIN AROUND
PERIMETER OF PIT WALL.
SEE CIVIL (TYP)
GALV. L3x3x1/4 LLV WITH
1/2" DIA x 4" LONG HEADED
STUDS SHOP WELDED TO
ANGLE @ 18"O.c.
CONT. WATERPROOF
MEMBRANE. (TYP)
GALV. L2x2x1/4 LLV AROUND
PERIMETER SUPPORTING
FLOOR GRATING
9'-2"
1'-0"8"
1'-10"3'-6"2'-2"
7'-6"
C
L R
℄ PIT
FIN. FLOOR
0'-0"
T.O. PIT FTG
-5'-0"
REMOVABLE CORRUGATED METAL GRATING
TO HAVE NON-SLIP AND ANTI-SPARK FINISH
AT TOP AND BOTTOM OF PIT WITH MINIMUM
LIVE LOAD CAPACITY OF 100 PSF
#6 @ 18"o.c. FRAMING BAR (TYP)
#6 VERTICAL @ 18"o.c. AND
(5) #6 HORIZONTAL BARS.
(TYP)
PROVIDE CHAMFERED
EDGE AT ALL RECESS
CORNERS (TYP)
1'-0" 1'-2"
1'-0"
LIGHT
RECESS
OIL
EVAC
RECESS
CONT. GALV. L3"x3"x1/4" WITH
1/2" DIA. POST INSTALLED
ANCHORS @ 12"o.c. (TYP)
CONT. BULB-TYPE WATERSTOP.
(TYP)
CONT. 2X6 SHEAR KEY (TYP)
#6 @ 18"o.c. EF
#6 @ 12"o.c. EF
#6 @ 18"o.c. FRAMING
BAR
#6 @ 18"o.c. WITH 90
DEG HOOK AT EA END
(TYP)
#6 @ 6"o.c. EW T&B OVER OIL
EVAC RECESS
RIDGID INSULATION UNDER SLAB ON
GRADE AND BEHIND PIT WALL-SEE
ARCH FOR DETAILS. (TYP.)
CHASE COORD. WITH MEP
DWGS.
3"3"
1'-10"3'-6"3'-4"
8'-8"
℄ PIT 3"3"
3'-0"2'-0" 2'-0"
2'-0"
1'-1"2'-7"
CHASE FOR 6" DIA. PVC
SLEEVE COORD. WITH
MEP DWGS.
2'-4"
LIGHT
RECESS
OIL
EVAC
RECESS
1'-0"
SUMP PIT-SEE DETAILS 2 & 3
ON THIS SHEET FOR REINF
INFORMATION.
SUMP PIT FOUNDATION.
COORDINATE LOCATION
WITH MEP DWGS.
#6 @ 18"o.c. EF
#6 @ 12"o.c. EF
#6 @ 18"o.c.
FRAMING BAR
#6 @ 6"o.c. EW T&B
OVER HOSE REEL
RECESS
FIN. FLOOR
0'-0"
T.O. PIT FTG
-5'-0"
1'-0"
Sheet
Reference
Number:
ofSheet
A
B
C
D a t e
A p p r o v a l D e s c r i p t i o n S y m b o l
P l o t
S c a l e
D a t e
F i l e n a m e
D a t
D r a
S C
R e v i e w e d
B y
S u b m i t t e d
B y
K e n a l l F
N I
C h e c k e d
B y
D R
W
P l o t
D a t e
D e s i g n e d
B y
D R
W
S o l i c i t a t i o n
N o
US Army Corps of Engineers
Fort Worth District
D E
S I G
N
O
F
T
E M
F
R
E N
O V
A T
I O
N S
F O
O
D
T
E X
A S
B L
P r o j e c t
N o
W
G
D
R E
V I S
I O
N S
In te rn at io na l P la za
Su ite
Fo rt
W or th , T ex as
-4
Ph on e
7)
-7
Fa x
7)
-7
N O
T
F
N
S T
R U
C T
I O
N
T H
C
U M
E N
T
L E
A S
E
P U
R P
O S
E
O
F
I N
T E
R
V
I E
W
U
N D
E
A U
T H
O R
I T
Y
O
F
D
A Y
A
D
A Y
A N
D A
N D
A
P
E
T E
X A
S
N
O
D
A T
E
B
E
U
S E
D
F
N
S T
R U
C T
I O
N
B I D
D I N
G
O
R
P
E R
M
R
P O
S E
S
K e n a l l
C o n s u l t i n g
E n g i n e e r s
I n c
T e x a s
R e g i s t e r e d
E n g i n e e r i n g
F i e e s e a n d
N i c h o l s
I n x a s
R e g i s t e r e d
E n g i n e e r i n g
F i
S
U B
M I T
T A
L
S
E T
S-401
M A
I N
T E
N A
N C
E
P
A
T
A I
U I L D
I N
G
GB-30
P-8
P-58
G B
A
GB-73
P-17P-18
G B
G B
G B
GB-3
GB-6
GB-10
GB-28 GB-25
GB-23
GB-21
GB-19
GB-69
G B
G B
G B
GB-1
GB-2
P-2
GB-4
GB-5
P-4
GB-7
GB-8
GB-9
P-7
GB-29
P-48
GB-27 GB-26
P-50
GB-24
P-23
GB-22
P-53
GB-20
P-34
GB-18 GB-17
P-32
GB-92
P-30
G B
GB-40
GB-39
G B
G B
G B
G B
G B
G B
GB-42
GB-54 GB-55
G B
G B
A
G B
GB-52 GB-53
G B
GB-41
GB-72
GB-71
G B
P-62
P-61
GB-51
GB-50
GB-56
GB-57
G B
G B
G B
GB-66
GB-65
G B
GB-64
GB-70
GB-67
GB-68
G B
G B
G B
GB-77
GB-82
GB-83
GB-87
GB-88
GB-89
GB-90
GB-85
GB-86
G B
G B
G B
G B
G B
G B
G B
G B
GB-91
G B
G B
GB-74
GB-75
S L O
P E
S L O
P E
S L O
P E
S L O
P E
P-1 P-3
P-46
P-5
P-6
P-5
P-52
P-47
P-49
P-24
P-22
P-54
P-35
P-33
P-31
P-37
P-28
P-29
P-27
P-26
P-25
P-64
P-56
P-57
P-59
P-21
P-9 P-10
P-60
P-11
P-12
P-13
P-14
P-15
P-63
P-20
P-19
A
B C D E F G.9 JG.7
1.11.1
F.5 H
2.3
2.5
3.5
4.4
4.7
3.7
F.7 F.9
1.2
4.3
A BA.8A.2
G
SLAB TO BE DEMO'D
SE-101
E X
I S
T I N
G
F
O U
N D
A T
I O
N
B U
I L D
I N
G
Sheet
Reference
Number:
ofSheet
A
B
C
D a t e
A p p r o v a l D e s c r i p t i o n S y m b o l
P l o t
S c a l e
D a t e
F i l e n a m e
D a t
D r a
S C
R e v i e w e d
B y
S u b m i t t e d
B y
K e n a l l F
N I
C h e c k e d
B y
D R
W
P l o t
D a t e
D e s i g n e d
B y
D R
W
S o l i c i t a t i o n
N o
US Army Corps of Engineers
Fort Worth District
D E
S I G
N
O
F
T
E M
F
R
E N
O V
A T
I O
N S
F O
O
D
T
E X
A S
B L
P r o j e c t
N o
W
G
D
R E
V I S
I O
N S
In te rn at io na l P la za
Su ite
Fo rt
W or th , T ex as
-4
Ph on e
7)
-7
Fa x
7)
-7
N O
T
F
N
S T
R U
C T
I O
N
T H
C
U M
E N
T
L E
A S
E
P U
R P
O S
E
O
F
I N
T E
R
V
I E
W
U
N D
E
A U
T H
O R
I T
Y
O
F
D
A Y
A
D
A Y
A N
D A
N D
A
P
E
T E
X A
S
N
O
D
A T
E
B
E
U
S E
D
F
N
S T
R U
C T
I O
N
B I D
D I N
G
O
R
P
E R
M
R
P O
S E
S
K e n a l l
C o n s u l t i n g
E n g i n e e r s
I n c
T e x a s
R e g i s t e r e d
E n g i n e e r i n g
F i e e s e a n d
N i c h o l s
I n x a s
R e g i s t e r e d
E n g i n e e r i n g
F i
S
U B
M I T
T A
L
S
E T
EXISTING GRADE BEAM W/ NEW SLAB OVERLAY - OVERALL
0 4 8 16
3/32" = 1'-0" (24"x36") 3/64" = 1'-0" (11"x17")
SCALE:
DRAWING ABBREVIATIONS BUILDING SUMMARY GENERAL NOTES
A ---------------------
A LABELCLASS A DOOR
A/C AIR CONDITION
A/C UNITAIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNLACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABELCLASS B DOOR
BALC BALCONY
BB BASEBOARD
BC BOOKCASE
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C CONC CAST CONCRETE
C LABELCLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER) BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABELCLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAS BD FASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRTW FIRE RETARDANT TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED CONTRACTOR
INSTALLED
GFGI GOVERNMENT INSTALLED FURNISHED
INSTALLED BY GOVERNMENT
GFRG GLASS-FIBER-REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC ROOM RECREATION ROOM
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
ST STAIRS
STD STANDARD
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
SUB FL SUBFLOOR
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
GENERAL LEGEND
LEGEND
NUMBERING SYSTEM:
A - 210
DISCIPLINE w/ LEVEL 2 DESINATOR:
C - CIVIL
L - LANDSCAPE
A - ARCHITECTURE
M - MECHANICAL
E - ELECTRICAL
P - PLUMBING
S - STRUCTURAL
K - FOOD SERVICE
SERIES NUMBER
SHEET NUMBER WITHIN
SERIES
CONCRETE/ PRECAST
CONCRETE
SOIL
SAND, EIFS FINISH COAT,
OR CEMENT PLASTER
BRICK
CMU
STONE
FIBERGLASS SEMI RIGID
INSULATION
FIBERGLASS BATT
INSULATION
MINERAL WOOL SEMI
RIGID INSULATION
EXPANDED
POLYSTYRENE RIGID
INSULATION
EXTRUDED
POLYSTYRENE RIGID
INSULATION
POLYISOCYANURATE
RIGID INSULATION
GYPSUM BOARD
EXTERIOR GYPSUM
SHEATHING
EXTERIOR CEMENT
BOARD
COATED GLASS MAT
WATER RESISTANT
GYP BD
PLYWOOD
COVER BOARD
MATERIALS
ANNOTATION CALLOUTS/DRAWING SYMBOLS
1i
GRID / COLUMN
LINE
DESIGNATOR
EQUIPMENT NUMBER
DOOR NUMBER
1i
WALL TYPE
WINDOW TYPE
Room name
101 ROOM NAME/NUMBER
REVISION TAG
PLAN NORTH
NORTH ARROW w/
TRUE NORTH
INDICATION
EGRESS ROUTE ID
AND SECTION
LENGTH
S
1 HR FIRE
S
S
S
1 HR FIRE/SMOKE WALL
4 HR FIRE
4 HR FIRE/SMOKE WALL
2 HR FIRE
2 HR FIRE/SMOKE WALL
3 HR FIRE
3 HR FIRE/SMOKE WALL
FIRE RATED WALL SYMBOLS:
Room
Rm_Occupancy
150 SF
EGRESS :Egress_ID
Egress_Length
ROOM OCCUPANCY
& AREA
ELEVATION NUMBER
SECTION
EXTERIOR ELEVATION
ENLARGEMENT,
DETAIL
SPOT ELEVATION
Name
Elevation
FLOOR LEVEL & NAME
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
SHEET KEYNOTE
A-101
Ref
R e f
Ref
R e f
INTERIOR ELEVATION
A-101
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
A-101
100000.A
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
FOR INTERIM REVIEW
ONLY, NOT FOR
CONSTRUCTION
TROY C. SECORD
TEXAS REGESTRATION
NO. 12994 A-001
G E
N E
R A
L N
O T
E S
A
B B
R E
V
IA
T
IO
N S
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
T C
S
M P
T
D R
R
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
M A
R K
D E
S C
R
IP
T
IO
N D
A
A
1.11.1
4.4
B
B C D E F G H J
AD-201
A1
AD-202
A1
AD-202
C1
AD-201
C1
MATCHLINE MATCHLINE
3.5
2.5
A.8A.2
62' - 0"
8" 20' - 4" 20' - 0" 20' - 4" 8"
8" 60' - 8" 1' - 4" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 20' - 0" 1' - 4"
204' - 0"
PLAN NORTH
A
B
KEY PLAN
1. VERIFY EXISTING CONSTRUCTION AND COORDINATE WITH
APPROVED CONSTRUCTION DOCUMENTS PRIOR TO AND DURING
CONSTRUCTION.
2. ITEMS THAT ARE SHOWN DASHED INDICATE LIMITS OF DEMOLITION
AND ARE TO BE REMOVED. DEMOLITION OF ITEMS INDICATED ON
DRAWINGS REFERS TO THE ITEM AND ITS RELATED ASSEMBLIES
UNLESS OTHERWISE NOTED.
3. PATCH ADJOINING CONSTRUCTION TO REMAIN AS TO NOT BE
READILY APPARENT THAT IT HAS BEEN ALTERED OR DISTURBED.
4. PROVIDE AND INSTALL ADEQUATE SHORING OF ALL LOAD BEARING
AREAS RELATED TO DEMOLITION. REFER STRUCTURAL.
5. REFER TO CIVIL, STRUCTURAL AND MEP DRAWINGS FOR
ADDITIONAL DEMOLITION REQUIREMENTS.
GENERAL NOTESLEGEND
TO BE DEMOLISHED
EXISTING PARTITION TO
REMAIN
LIMITS OF DEMOLITION
(ELEVATIONS)
EXISTING BALLARD TO REMAIN
EXISTING BALLARD TO BE REMOVED
AREA OF SLAB TO BE DEMOLISHED:
REFER STRUCT.
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
FOR INTERIM REVIEW
ONLY, NOT FOR
CONSTRUCTION
TROY C. SECORD
TEXAS REGESTRATION
NO. 12994 AD-101
D E
M O
L
IT
IO
N
P L
A N
F
IR
S
T F
L O
O R
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
T C
S
M P
T
D R
R
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
1/16" = 1'-0"AD-101
A1 DEMO PLAN - FIRST FLOOR
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
4'0' 8' 16'
GRAPHIC SCALE 1/16"=1'-0"
32'
B
B
AD-202
C1
A.8A.2
A1
AD-302
A3
AD-301
A1
AD-301
MATCHLINE MATCHLINE
02 41 00.05
02 41 00.02
02 41 00.0802 41 00.0802 41 00.05
02 41 00.02
02 41 00.06
02 41 00.0802 41 00.08
02 41 00.16
02 41 00.0602 41 00.06
02 41 00.0802 41 00.0802 41 00.0602 41 00.06
02 41 00.0602 41 00.0602 41 00.0602 41 00.0602 41 00.06
/A1 AD-103 /A1 AD-103
02 41 00.0802 41 00.08
DIVISION 802 41 00.0802 41 00.08
02 41 00.18
02 41 00.0602 41 00.0602 41 00.0602 41 00.06
8"
20' - 4" 20' - 0" 20' - 4"
8" 13' - 4 1/4" 11' - 8" 11' - 11 5/8" 11' - 8" 13' - 4 1/4"
/8
/8
/4
/8
AD-201
A1
02 41 00.0702 41 00.07
02 41 00.0702 41 00.07
PLAN NORTH
A
B
KEY PLAN
1. VERIFY EXISTING CONSTRUCTION AND COORDINATE WITH
APPROVED CONSTRUCTION DOCUMENTS PRIOR TO AND DURING
CONSTRUCTION.
2. ITEMS THAT ARE SHOWN DASHED INDICATE LIMITS OF DEMOLITION
AND ARE TO BE REMOVED. DEMOLITION OF ITEMS INDICATED ON
DRAWINGS REFERS TO THE ITEM AND ITS RELATED ASSEMBLIES
UNLESS OTHERWISE NOTED.
3. PATCH ADJOINING CONSTRUCTION TO REMAIN AS TO NOT BE
READILY APPARENT THAT IT HAS BEEN ALTERED OR DISTURBED.
4. PROVIDE AND INSTALL ADEQUATE SHORING OF ALL LOAD BEARING
AREAS RELATED TO DEMOLITION. REFER STRUCTURAL.
5. REFER TO CIVIL, STRUCTURAL AND MEP DRAWINGS FOR
ADDITIONAL DEMOLITION REQUIREMENTS.
GENERAL NOTESLEGEND
TO BE DEMOLISHED
EXISTING PARTITION TO
REMAIN
LIMITS OF DEMOLITION
(ELEVATIONS)
EXISTING BALLARD TO REMAIN
EXISTING BALLARD TO BE REMOVED
AREA OF SLAB TO BE DEMOLISHED:
REFER STRUCT.
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
FOR INTERIM REVIEW
ONLY, NOT FOR
CONSTRUCTION
TROY C. SECORD
TEXAS REGESTRATION
NO. 12994 AD-102
D E
M O
L
IT
IO
N
P L
A N
F
IR
S
T F
L O
O R
A R
E A
A
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
T C
S
M P
T
D R
R
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
1/8" = 1'-0"AD-102
A1 DEMO PLAN - FIRST FLOOR
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
KEYNOTES
KEYNOTE NOTE
02 41 00.02 REMOVE A PORTION OF EXIST. EXTERIOR WALL SYSTEM INCLUDING
8" REINFORCED CMU, MTL. WALL PANELS AND WALL GIRTS. REFER
DEMOLITION FLOOR PLAN, EXTERIOR ELEVATIONS AND WALL
SECTIONS FOR LIMITS OF WALL REMOVAL.
02 41 00.05 REMOVE EXIST. MTL. WINDOW AND PREPARE OPENING FOR NEW
CONSTRUCTION.
02 41 00.06 REMOVE EXIST. MTL. DOOR AND FRAME.
02 41 00.07 REMOVE EXIST. STEEL PIPE BOLLARD.
02 41 00.08 REMOVE EXIST. 8" CMU INTERIOR PARTITIONS.
02 41 00.16 EXIST. FLOOR SLAB TO BE CUT AND REMOVED FOR CONSTRUCTION
OF NEW SERVICE PIT REFER STRUCT.
02 41 00.18 REMOVE EXTERIOR STEEL STAIR SYSTEM.
DIVISION 8 OPENINGS
0' 8' 16'
GRAPHIC SCALE 1/8" = 1'-0"
4'
A
1.11.1
4.4
B
B C D E F G H J
AD-202
C1
AD-201
C1
3.5
2.5
B3
AD-301
B1
AD-301
B1
AD-302
A1
AD-302
A1
AD-301
MATCHLINE MATCHLINE
02 41 00.05
02 41 00.2602 41 00.2602 41 00.26
02 41 00.0802 41 00.08
02 41 00.01
02 41 00.0602 41 00.0602 41 00.0602 41 00.0602 41 00.06
02 41 00.01
02 41 00.01
02 41 00.01
/A1 AD-102 /A1 AD-102
02 41 00.0602 41 00.0602 41 00.06
02 41 00.0802 41 00.0602 41 00.06
02 41 00.0502 41 00.0502 41 00.06
02 41 00.0102 41 00.01
02 41 00.01
02 41 00.01
02 41 00.06
02 41 00.0802 41 00.08
02 41 00.0602 41 00.06
02 41 00.0802 41 00.0802 41 00.0802 41 00.0602 41 00.06
02 41 00.06
02 41 00.06
02 41 00.08
02 41 00.08
02 41 00.12
02 41 00.12
02 41 00.13
02 41 00.13
A-401
C1
02 41 00.0702 41 00.07
02 41 00.0702 41 00.07
02 41 00.0702 41 00.0702 41 00.0702 41 00.07
4' - 8 1/4" 8' - 8" 11' - 7" 5' - 8" 5' - 9" 11' - 8" 13' - 11 7/8"
02 41 00.0802 41 00.0802 41 00.08
02 41 00.0802 41 00.0802 41 00.08
02 41 00.0702 41 00.07
02 41 00.0702 41 00.07
02 41 00.0702 41 00.0702 41 00.0702 41 00.07
02 41 00.02
CO. A REPAIR
AREA
02 41 00.13
02 41 00.13
02 41 00.26
02 41 00.26
02 41 00.2602 41 00.2602 41 00.2602 41 00.26
02 41 00.08
02 41 00.0702 41 00.07 02 41 00.0702 41 00.07
02 41 00.0702 41 00.0702 41 00.0702 41 00.07
02 41 00.0702 41 00.07
02 41 00.0702 41 00.0702 41 00.0702 41 00.0702 41 00.0702 41 00.07
72' - 8" 66' - 0"
3' - 4"
2' - 0"
6' - 4" 35' - 0" 16' - 8"
1' - 4 3/8"
73' - 3 5/8" 66' - 0" 3' - 4"
61' - 4 3/8" 142' - 7 5/8"
204' - 0"
/8
"8
/2
142' - 0"
BATTALION
REPAIR BAYS
02 41 00.0602 41 00.02
PLAN NORTH
A
B
KEY PLAN
1. VERIFY EXISTING CONSTRUCTION AND COORDINATE WITH
APPROVED CONSTRUCTION DOCUMENTS PRIOR TO AND DURING
CONSTRUCTION.
2. ITEMS THAT ARE SHOWN DASHED INDICATE LIMITS OF DEMOLITION
AND ARE TO BE REMOVED. DEMOLITION OF ITEMS INDICATED ON
DRAWINGS REFERS TO THE ITEM AND ITS RELATED ASSEMBLIES
UNLESS OTHERWISE NOTED.
3. PATCH ADJOINING CONSTRUCTION TO REMAIN AS TO NOT BE
READILY APPARENT THAT IT HAS BEEN ALTERED OR DISTURBED.
4. PROVIDE AND INSTALL ADEQUATE SHORING OF ALL LOAD BEARING
AREAS RELATED TO DEMOLITION. REFER STRUCTURAL.
5. REFER TO CIVIL, STRUCTURAL AND MEP DRAWINGS FOR
ADDITIONAL DEMOLITION REQUIREMENTS.
GENERAL NOTESLEGEND
TO BE DEMOLISHED
EXISTING PARTITION TO
REMAIN
LIMITS OF DEMOLITION
(ELEVATIONS)
EXISTING BALLARD TO REMAIN
EXISTING BALLARD TO BE REMOVED
AREA OF SLAB TO BE DEMOLISHED:
REFER STRUCT.
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S a v o y D ri v e S u it e
H o u s to n T e x a s
-2
-8
FOR INTERIM REVIEW
ONLY, NOT FOR
CONSTRUCTION
TROY C. SECORD
TEXAS REGESTRATION
NO. 12994 AD-103
D E
M O
L
IT
IO
N
P L
A N
F
IR
S
T F
L O
O R
A R
E A
B
C O
R P
S O
F E
N G
IN
E
E R
S F
O R
T W
O R
T H
T
E X
A S
T C
S
M P
T
D R
R
A P
R
IL
- W G
-1 -D
-0
95% DESIGN SUBMITTAL
F O
R T
H O
O D
T
E X
A S
D E
S
IG
N O
F T
E M
F R
E N
O V
A T
IO
N
S B
L D
G
1/8" = 1'-0"AD-103
A1 DEMO PLAN - FIRST FLOOR
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
KEYNOTES
KEYNOTE NOTE
02 41 00.01 REMOVE EXIST. OVERHEAD COILING DOOR SYSTEM.
02 41 00.02 REMOVE A PORTION OF EXIST. EXTERIOR WALL SYSTEM INCLUDING
8" REINFORCED CMU, MTL. WALL PANELS AND WALL GIRTS. REFER
DEMOLITION FLOOR PLAN, EXTERIOR ELEVATIONS AND WALL
SECTIONS FOR LIMITS OF WALL REMOVAL.
02 41 00.05 REMOVE EXIST. MTL. WINDOW AND PREPARE OPENING FOR NEW
CONSTRUCTION.
02 41 00.06 REMOVE EXIST. MTL. DOOR AND FRAME.
02 41 00.07 REMOVE EXIST. STEEL PIPE BOLLARD.
02 41 00.08 REMOVE EXIST. 8" CMU INTERIOR PARTITIONS.
02 41 00.12 REMOVE EXIST. TOILET PARTITIONS, TYPICAL.
02 41 00.13 REMOVE EXIST. PLUMBING FIXTURES (TOILETS, SINKS AND
SHOWERS) COMPLETE IN THIS AREA, TYPICAL.
02 41 00.26 REMOVE EXIST. INTERIOR PARTITIONS TO LIMITS SHOWN.
0' 8' 16'
GRAPHIC SCALE 1/8" = 1'-0"
4'
| Drawing ( Tech Exh B) 25 |
| Drawing ( Tech Exh B) 26 |
| Drawing ( Tech Exh B) 27 |
| Drawing ( Tech Exh B) 28 |
| Drawing ( Tech Exh B) 29 |
| Drawing ( Tech Exh B) 30 |
| Drawing ( Tech Exh B) 31 |
| Drawing ( Tech Exh B) 32 |
| Drawing ( Tech Exh B) 33 |
| Drawing ( Tech Exh B) 34 |
| Drawing ( Tech Exh B) 35 |
| Drawing ( Tech Exh B) 36 |
File details come from the government source that posted it.