0011181627 TC011607P

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

The purpose of this amendment is to respond to industry questions, add Technical Exhibit D revised draw ings and Technical Exhibit E Mech As Builts.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 4

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 14-Sep-2018

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W9115118B0029

X 9B. DATED (SEE ITEM 11)

22-Aug-2018

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

14-Sep-2018

CODE

MISSION AND INSTALLATION CONTRACTING

MISSION CONTRACTING OFFICE (MCO)

36000 DARNALL LOOP, ROOM 1300B

FORT HOOD TX 76544-5095

W91151 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W9115118B0029

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION 00010 - SOLICITATION CONTRACT FORM

TABLE OF CONTENTS

The Table of Contents has changed from:

Exhibit/Attachment Table of Contents

DOCUMENT TYPE DESCRIPTION PAGES DATE

Exhibit A Technical Exhibit-A 3313 01-MAY-2018 Exhibit B Technical Exhibit-B 17 01-MAY-2018 Exhibit C Technical Exhibit-C 32 02-JUN-2003 to:

Exhibit/Attachment Table of Contents

DOCUMENT TYPE DESCRIPTION PAGES DATE

Exhibit A Technical Exhibit-A 3313 01-MAY-2018 Exhibit B Technical Exhibit-B 17 01-MAY-2018 Exhibit C Technical Exhibit-C 32 02-JUN-2003 Exhibit D Tech Exhibit-D-Drawings

Revised

20 01-MAY-2018

Exhibit E Tech Exhibit-E-Mech-AS

BUILTS

1 14-SEP-2018

The following have been added by full text:

RESPONSE TO INDUSTRY RESPONSES

W91151-18-B-0029 Responses to Questions from Industry

Renovate Bldg. 91012

1. During the site walk, we saw that the fire sprinkler heads need to be relocated due to new walls. There are existing walls that are not within code for sprinkler head location. Do you want us to move these heads as well?

A: These walls are not within scope, and must remain undisturbed during construction. To be clear, due to security and network requirements, these walls, and the cable tubing attached to it are to be avoided at all costs during construction.

2. We understand that we have to replace some carpet tiles, however, due to the age and condition the new tiles will not match the existing tiles. Do you want us to replace the tiles in the entire room?

A: Replacing all of the floor tiles in this room will not be added to this scope of work. After meeting with the facility user, we now know that they will have a stock of floor tiles available for contractors to use when existing walls are removed. Receipt of flooring tile from the facility user will be discussed upon award of this project, and coordinated during preconstruction planning meetings and activities.

3. Can you provide existing HVAC plans with flex runouts?

A: Please see attached.

4. On the second floor, we have to replace some of the elevated floor tiles. Are there some in the mechanical room that we can use or do we need to provide and match existing? If we are to match the existing, can you provide a style, color, and size?

A: A stock of floor tiles available for contractors to use when existing walls are removed. Receipt of flooring tile from the facility user will be discussed upon award of this project, and coordinated during preconstruction planning meetings and activities.

5. Will additional modifications to the drawings be made per marked up drawings that were located in room 203 on the job-site visit?

A: Please disregard the drawings posted in room 203 during the job site visit. Only consider the changes included in the updated project drawing set issued during this pre-award RFI period.

6. How should wall type B be attached to the modular flooring per detail page A-301? Will wall type B require overhead bracing?

A: Use fasteners to install bottom track to floor.

SECTION 00100 - BIDDING SCHEDULE/INSTRUCTIONS TO BIDDERS

The following have been modified:

52.252-3 ALTERATIONS IN SOLICITATION (APR 1984)

Portions of this solicitation are altered as follows:

Amendment 01 – Responses to questions from industry (RFIs), Technical Exhibit D Revised Drawings, Technical Exhibit E Mech As Builts

(End of Provision)

SECTION 00700 - CONTRACT CLAUSES

The following have been modified:

252.236-7001 CONTRACT DRAWINGS AND SPECIFICATIONS (AUG 2000)

(a) The Government will provide to the Contractor, without charge, one set of contract drawings and specifications, except publications incorporated into the technical provisions by reference, in electronic or paper media as chosen by the Contracting Officer.

(b) The Contractor shall--

(1) Check all drawings furnished immediately upon receipt;

(2) Compare all drawings and verify the figures before laying out the work;

(3) Promptly notify the Contracting Officer of any discrepancies;

(4) Be responsible for any errors that might have been avoided by complying with this paragraph (b); and

(5) Reproduce and print contract drawings and specifications as needed.

(c) In general--

(1) Large-scale drawings shall govern small-scale drawings; and

(2) The Contractor shall follow figures marked on drawings in preference to scale measurements.

(d) Omissions from the drawings or specifications or the misdescription of details of work that are manifestly necessary to carry out the intent of the drawings and specifications, or that are customarily performed, shall not relieve the Contractor from performing such omitted or misdescribed details of the work. The Contractor shall perform such details as if fully and correctly set forth and described in the drawings and specifications.

(e) The work shall conform to the specifications and the contract drawings identified on the following index of drawings:

Title File Drawing No.

Specification Technical Exhibit-A 3313 Revised Drawings Technical Exhibit-B 20 As Builts Technical Exhibit-C 32 Revised Drawings Technical Exhibit-D 20 Mech As Builts Technical Exhibit-E 1

(End of clause)

(End of Summary of Changes)