Attachment-Drawing.pdf
PDF 1 MB Posted
- Attached to
- Replace Interior and Exterior Lights with LED at Bldg. 577, 578, 579, 580, and 581, Camp Walker
- Solicitation number
- W90VN924R0161
About this file
This document is a Request for Proposals (RFP) for the replacement of interior and exterior lights with LED fixtures at Buildings 577, 578, 579, 580, and 581 at Camp Walker. The scope of work includes replacing all light fixtures with LED models, repairing any resulting damage to walls or ceilings, and coordinating with the existing lighting control system. The solicitation number is W90VN924R0161, and the closing date and time is August 23, 2024 at 1:00 PM Korea local time. The contracting agency is the Department of the Army Materiel Command Army Contracting Command. The document provides detailed lighting fixture schedules, installation requirements, and general notes for the contractor to follow. No set-asides or pricing terms are specified.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP-W90VN924R0161.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
392391
KELLY FIELD
Golf Course
Tennis Court
DRIVING
RANGE
Golf Course
Golf Course
Golf Course
SKATE
PARK
661662
PENNSYLVANIA AVENUE
W I S
C O
N S I N
S
T R
E E
T
IN
DI
ANA
AVENUE
W
IS
C O
N S
IN
S T R E E T
U T
A H
S T R E E T
GEORGIA STREET
T E
X A S
S T
R E E T
R H
O D
E
IS
L A
N D
S
T R
E E
T T
E X
A S
S
T R
E E
T
WASHINGTON STREET
C A L
IF
O R
N
IA
S T
R E E T
GEORGIA STREET
N E
B R
A S
K A
S
T R
E E
T
C A L
IF
O R
N
IA
S T
R E E T
R H
O D
E
IS
L A
N D
S
T R
E E
T
P E N N S Y L V A N
IA
A V E N U E
GEORGI
A
STREET
T E
X A S
S T
R E E T
Substation
Gate #6
Gate #4
B577, 578, 579, 580, 581, CAMP WALKER
PROJECT LOCATION
J1-00092-4J
LOCATION PLAN
1 08
REPLACE INTERIOR AND EXTERIOR LIGHTS WITH LED
1.
2.
3.
6.
OF CONSTRUCTION SHALL BE USED.
NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE
EXISTING UTILITIES AS A RESULT OF HIS/HER WORK.
OF CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL PAY FOR ALL DAMAGES TO
TO UTILITIES. NOTIFY THE OWNER’S REPRESENTATIVE OF ANY UNDERGROUND UTILITIES IN THE WAY
EXTREME CAUTION AND MUST EXERCISE PROPER CARE DURING EXCAVATION TO PREVENT DAMAGE
ACCURACY OR THE EXISTENCE OF OTHER OBSTACLES WHICH MAY BE ENCOUNTERED WORK WITH
PLANS ARE FROM THE LATEST AVAILABLE RECORDS BUT ARE NOT GUARANTEED AS TO THE
THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITIES AND STRUCTURES AS SHOWN ON THESE
4.
LOCATIONS AND DEPTHS PRIOR TO EXCAVATION FOR THE NEW LINES.
CONTRACTOR SHALL EXPOSE THE EXISTING LINES AT THE PROPOSED CONNECTIONS TO VERIFY THEIR
WHEREVER CONNECTIONS OF NEW UTILITIES TO EXISTING UTILITIES ARE SHOWN ON THE PLANS, THE
THE PROJECT AREA PRIOR TO EXCAVATING. THE CONTRACTOR SHALL COORDINATE ALL WORK.
THE CONTRACTOR SHALL NOTIFY ALL AGENCIES TO VERIFY THE ACTUAL LOCATION OF ALL UTILITIES IN
5.
ADDITIONAL COSTS TO THE OWNER.
SCHEDULED TO REMAIN DURING THE CONSTRUCTION PERIOD WHICH SHALL BE REPAIRED AT NO
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES INCURRED TO EXISTING WORK
7.
PATCHING SHALL MATCH THE FINISH OF THE ADJACENT SURFACES.
THE CONTRACTOR SHALL PATCH ALL SURFACES EXPOSED FROM CUTTING, AND/OR REMOVAL WORK.
8.
ACCESSIBILITY GUIDELINES (ADAAG).
ALL STANDARDS, REQUIREMENTS AND GUIDELINES OF THE AMERICANS WITH DISABILITIES ACT
ALL GOVERNING AGENCIES. THIS WORK SHALL BE DESIGNED AND CONSTRUCTED TO CONFORM WITH
ALL WORK SHALL CONFORM TO ALL APPLICABLE LAWS, CODES, REGULATIONS, AND ORDINANCES OF
9. ALL DIMENSIONS SHOWN ON FLOOR PLAN ARE TO FACE OF FINISH, UNLESS OTHERWISE.
10.
PROVIDE DUST CONTROL MEASURES AS REQUIRED.
CLEAN AND FREE FROM ACCUMULATION OF WASTE MATERIALS AND RUBBISH. CONTRACTOR SHALL
AREA, THE OWNER’S PREMISES, INCLUDING STREETS AND OTHER AREAS USED BY THE CONTRACTOR
CONTRACTOR SHALL, AT ALL TIMES, DURING THE COURSE OF THE WORK, KEEP THE CONSTRUCTION
11.
OF OPERATIONS, INTERRUPTION OF MECHANICAL AND ELECTRICAL UTILITIES.
DELIVERY ACCESS TO AND FROM WORK, SPECIAL NOISY OPERATIONS, TIMING OF WORK, SEQUENCE
COORDINATE ALL OPERATIONS WITH THE OWNER’S REPRESENTATIVE FOR MATERIALS STORAGE,
12.
DEBRIS, RUBBISH, AND CONSTRUCTION MATERIAL AT TIME OF FINAL ACCEPTANCE.
REMOVE BARRICADE AFTER COMPLETION OF THE PROJECT AND CLEAN THE PROJECT AREA OF ALL
PREVENT PEOPLE FROM ENTERING THE PROJECT AREA AND TO PROTECT THE ENCLOSED PROPERTY.
CONTRACTOR SHALL PROVIDE BARRICADES, AS REQUIRED, AND ACCEPTABLE TO THE OWNER TO
13.
REPRESENTATIVE.
TRADE SHALL BE USED TO RESOLVE SUCH DISCREPANCIES AND MUST BE APPROVED BY THE OWNER’S
SUBMIT SHOP DRAWINGS ON HOW THEY WILL RESOLVE SUCH DISCREPANCIES. GENERAL PRACTICE OF
SHALL BE BORNE BY THE CONTRACTOR AND IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO
QUESTIONS RAISED DURING CONSTRUCTION PHASE THAT MAY RESULT IN EXTRA COST, SAID COST
ALL DISCREPANCIES FOUND ON DRAWINGS DURING CONSTRUCTION PHASE, ANY DISCREPANCIES OR
IT SHALL BE CONTRACTOR’S RESPONSIBILITY TO NOTIFY THE OWNER’S REPRESENTATIVE FOR ANY OR
14. CONTRACTORS SHALL VERIFY ALL QUANTITIES.
STATE PROPERTY IN ACCORDANCE WITH ALL LOCAL GOVERNING LAWS AND REGULATIONS.
BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF OUTSIDE THE LIMITS OF
ALL MATERIALS REQUIRED TO BE DISPOSED OF IN THIS PROJECT UNLESS REQUIRED TO BE SALVAGED, INTENDED TO LIMIT THE WORK REQUIRED IN ANY WAY.
TITLES, CAPTIONS, HEADINGS, ETC. ARE INTENDED FOR GENERAL REFERENCE AND ARE NOT
THE ABOVE NOTES APPLY TO THE FULL SET OF CONSTRUCTION DOCUMENTS.
GENERAL NOTES
1.
2.
3.
15. FILL EXISTING DUCT AND PIPE HOLE W/ CONCRETE.
16.
RESPONSIBLE FOR REPAIR OR REPLACEMENT OF ACCESS DOOR AND WALL.
THE CONTRACTOR SHALL VERIFY THE NEW EQUIPMENT ACCESS CONDITIONS AT JOB SITE AND WILL BE
17.
18.
19.
AND SPECIFIC NOTES ON THE CONTRACT DRAWINGS.
THE CONTRACTOR SHALL FOLLOW THE CONSTRUCTION WORK AS INDICATED ON THE GENERAL NOTES
20.
CONTRACTOR SHALL SUBMIT ALL MATERIAL & COLOR SAMPLES TO DPW FOR APPROVAL.
COLOR AND PATTERN WHICH MANUFACTURERS STANDARD MUST APPROACH.
MATCH FOR MANUFACTURER COLOR IS NOT REQUIRED. THE SELECTIONS SERVE ONLY TO INDICATE
NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE MANUFACTURERS INDICATED. AN EXACT
COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR IDENTIFICATION PURPOSES ONLY, AND
CONTRACT DRAWING.
THE CONTRACTING OFFICER. A SHOP DRAWING SHALL NOT BE THE EXACT DUPLICATION OF THE
CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR APPROVAL TO
6.
REMOVE & CLEAN EXISTING FINISH MATERIAL & ADHESIVE BY GRINDING TO RECEIVE VCT & TILE.
7.
REMOVE & CLEAN EXISTING PAINT BY SAND PAPER/ GRINDING FOR NEW PAINTING AND COATING.
8.
FREE.
SHEET (MSDS), WRITTEN IN ENGLISH, FROM THE MANUFACTURE SHOWING THE PRODUCT IS LEAD
OF THIS PROJECT. THE CONTRACTOR WILL PROVIDE A CERTIFICATE OR MATERIAL SAFETY DATA
LESS THAN 0.05 PERCENT LEAD BY WEIGHT OF THE NON- VOLATILE SOLIDS) DURING THE EXECUTION
THE CONTRACTOR IS REQUIRED TO USE "LEAD FREE" COATINGS (LIQUID PAINTS OR COATINGS WITH
CONTRACT, AND SHALL BE RESOLVED BEFORE PROCEEDING WITH THE WORK.
OMISSIONS OR CONFLICTS WHICH PREVENT HIM OR HER FROM FULFILLING THE TERMS OF THE
CONTRACTOR SHALL PROMPTLY NOTIFY THE OWNER’S REPRESENTATIVE OF ANY DISCREPANCIES, WITH THE REQUIRED WORK.
SHALL VERIFY ALL CONDITIONS AND DIMENSIONS RELATING TO THE PROJECT BEFORE COMMENCING
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND
WITHOUT WRITTEN APPROVAL OF THE OWNER’S REPRESENTATIVE.
THAT THE PROPER REVISIONS MAY BE MADE. MODIFICATION OF DETAILS SHALL NOT BE MADE
CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE OWNER’S REPRESENTATIVE SO
BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS
ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE
SPECIFIC NOTES
MATERIAL NOTES
TRAFFIC AND OPERATIONS.
NECESSARY PRECAUTIONS FOR THE PROTECTION AND SAFETY OF THE PUBLIC AND/OR MILITARY
BARRICADES, MARKERS, CONES AND OTHER PROTECTIVE FACILITIES AND SHALL TAKE ALL
THE CONTRACTOR SHALL PROVIDE, INSTALL, AND MAINTAIN ALL NECESSARY SIGNS, LIGHTS, FLARES, HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
THE CONTRACTING OFFICER.
AREAS CAUSED BY THIS PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS AS DIRECTED BY
THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING
OFFICER.
ANY DISCREPANCIES SHALL BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE CONTRACTING
PRIOR TO COMMENCING ANY CONSTRUCTION.
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION AND DIMENSIONS
THROUGH COR.
NEW SURVEY REPORT AND ASBESTOS REMOVAL DOCUMENTATION TO ENVIRONMENTAL OFFICE
THE KOREA ENVIRONMENTAL GOVERNING STANDARD (KEGS). THE CONTRACTOR SHALL PROVIDE THE
PRIOR TO ANY WORK TO ASSURE THAT APPROPRIATE ASBESTOS CONTROL IS IN ACCORDANCE WITH
THE WORK AREA WILL NEED TO BE RE SURVEYED AND ASBESTOS MATERIALS SHOULD BE REMOVED
CONTRACTOR SHALL CASE WORK IN THE AFFECTED AREA AND NOTIFY THE CONTRACTING OFFICER.
WORK. HOWEVER, IF SUSPECTED ASBESTOS CONTAINING MATERIAL ARE DISCOVERED, THE
FREE. TESTS HAVE INDICATED THAT ASBESTOS IS NOT PRESENT IN THE AREA AFFECTED BY THIS
OR MSDS, WRITTEN IN ENGLISH, FROM THE MANUFACTURER VERIFYING THE PRODUCT IS ASBESTOS
WEIGHT) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR WILL PROVIDE A CERTIFICATE
THE CONTRACTOR IS REQUIRED TO USE "ASBESTOS FREE" MATERIALS (LESS THAN 1 PERCENT BY
CONTRACT.
ACCOMPLISH THE ARCHITECTURAL SCOPE OF WORK AT NO ADDITIONAL COST TO THE PROJECT
AGENCY, KOREA REGION OFFICE" FROM A PART OF THIS PROJECT. THE DETAILS WILL BE UTILIZED TO
PROJECTS, KOREA, NOVEMBER 30, 2015, DEPARTMENT OF THE ARMY INSTALLATION MANAGEMENT
THE ARCHITECTURAL STANDARD DRAWINGS SHOWN IN THE "STANDARD DETAIL DRAWINGS FOR O&MA
S
LEGEND
SCOPE OF WORK
TOGGLE SWITCH
PANEL BOARD
1.
1’ X 4’ RECESSED LED LIGHTING FIXTURE, TYPE "A,B"
1’ X 4’ RECESSED LED LIGHTING FIXTURE, EMERGENCY, TYPE "A,B"
SURFACE MOUNTED LED LIGHT FIXTURE, INCLUDING TYPE "E,F,I"
4’ LONG WALL MOUNTED LED LIGHTING FIXTURE, INCLUDING TYPE "D"
2’ X 2’ LED LIGHTING FIXTURE, INCLUDING TYPE "C"
5.
J1-00092-4J
ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE NATIONAL
ELECTRICAL CODE(2023), NATIONAL ELECTRICAL SAFETY CODE, FIRE CODE AND SPECIFICATIONS.
3.
1.
WALL PACK LED LIGHT FIXTURE, INCLUDING TYPE "G, H, J"
USE THESE MATERIALS IN PRIORITY.
LIGHT FIXTURES TYPE A, C, F, G, H ARE STORED IN THE DPW WAREHOUSE. THE CONTRACTOR SHALL
WATTSTYPELAMP TYPE
LED
LED
LED
LED
LED
A
INSTALLATION TYPE
CEILING RECESSED30
SURFACE MOUNT
SURFACE MOUNT
C
F
G
H
SURFACE MOUNT
QY
LED LIGHT FIXTURED STORED IN DPW WAREHOUSE
2.
4.
5.
6.
WORK.
OF THIS WORK MUST BE DONE TO INSURE ROUGH- IN WORK IS ACCOMPLISHED PRIOR TO FINISHING
REPLACEMENT OF MECHANICAL, ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM COORDINATION
CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING TO MAKE WAY FOR THE INSTALLATION AND
INCONVENIENCE TO THE CUSTOMER’S MISSION OPERATION.
APPROVAL FROM THE GOVERNMENT AND EXECUTE WORK STAGE BY STAGE WITHOUT ANY
THE CONTRACTOR SHALL SUBMIT WORK SCHEDULE PRIOR TO COMMENCING THE WORK AND GET
CONTRACTOR.
THAT MAY OCCUR DURING THE COURSE OF HIS WORK SHALL BE RESTORED AT THE EXPENSE OF THE
THE CONTRACTOR SHALL TAKE MEASURES TO PROTECT EXISTING FACILITIES AND ANY DAMAGES
REQUIREMENTS MANUAL EM 385-1-1 LATEST EDITION.
THE CONTRACTOR SHALL PERFORM ALL WORKS IN ACCORDANCE WITH USACE SAFETY AND HEALTH
AND THE ENVIRONMENTAL GOVERNING STANDARDS FOR KOREA, USFK REGULATION 201-1.
ALL DISPOSAL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE KOREAN ENVIRONMENTAL LAWS
7.
8.
9.
10.
AND USER.
THE CONTRACTOR SHALL COORDINATE ALL PHASES OF WORK WITH THE CONTRACTING OFFICER
CONTRACTOR.
INCURRED FOR SPILL CONTAINMENT AND CLEAN- UP SHALL BE THE RESPONSIBILITY OF THE
OFFICER SHALL OVERSEE THE CLEAN- UP EFFORT AND RENDER THE SITE CLEAN. ALL COSTS
APPROPRIATE MEASURES TO CONTAIN AND ADEQUATELY CLEAN- UP THE SPILL. THE CONTRACTING
CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER AND UTILIZE
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY SEWAGE SPILLS CAUSED DURING
CONTRACTING OFFICER AT THE LOCATION INDICATED BY CONTRACTING OFFICER.
SALVAGEABLE MATERIALS SHALL BE REMOVED FROM WORK SITE IN A MANNER AND TURNED OVER TO
CONDITIONS AND SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL.
SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD
SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS.
MATCHING EXISTING COLOR AND FINISH.
ANY STRUCTURAL STEEL MEMBERS EXPOSED TO INTERIOR SPACE SHALL BE RE -PAINTED WITH
201-1, ENVIRONMENTAL GOVERNING STANDARD(EGS) CHAPTER 5 & CHAPTER 6.
STORED IN ACCORDANCE WITH THE CODE OF REGULATION 1910 SUBPART H AND USFK REGULATION
ALL HAZARDOUS MATERIAL AND HAZARDOUS WASTE USED/ CREATED DURING THE PROJECT MUST BE
11.
12.
13.
GENERAL NOTE
SCOPE OF WORK
LEGEND
2 08
4.
STATE AND CONTACT CONSULT WITH J&C.
WITH THEIR SYSTEM, RECONNECT THE EXISTING LIGHTING MOTION SENSORS TO THEIR ORIGINAL SYSTEMS DUE TO THEIR SENSOR ARE INSTALLED. IF NEW LIGHT FIXTURES ARE DISCONNECTED
THE CONTRACTOR SHALL COORDINATE WITH "JOHNSON CONTROLS (J&C)" FOR LIGHT SENSOR
DRAWINGS.
REPLACEMENT OF NEW LED LIGHT FIXTURES IN ACCORDANCE WITH THE SPECIFICATIONS AND
THE CONTRACTOR SHALL REPAIR DAMAGED GYPSUM BOARD WALLS OR CEILINGS DUE TO 2.
THE CONTRACTOR SHALL PAINT REPLACED NEW WALLS OR CEILINGS.3.
REPLACE INTERIOR AND EXTERIOR LIGHTS WITH LED
FLUSH MOUNT
SPECIFICATIONS AND DRAWINGS.
BETWEEN NEW JUNCTION BOXES AND LED LIGHT FIXTURES IN ACCORDANCE WITH THE
DRAWING. IN TERMS OF REPLACING CABLES AND FLEXIBLE CONDUITS, THE SCOPES ARE LIMITED LED LIGHT FIXTURES INCLUDING CABLES, JUNCTION BOXES AND FLEXIBLE CONDUITS IN THIS THE CONTRACTOR SHALL REPLACE INDICATED ALL INTERIOR AND EXTERIOR LIGHT FIXTURES WITH
14.
15.
16.
17.
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
B577 1ST FLOOR LIGHT PLAN
SCALE: 1 : 75
WATTSTYPE EALAMP TYPE
LED
LED
LED
LED
LED
LED
LED
A
B
C
INSTALLATION TYPE
CEILING RECESSED
CEILING RECESSED
LED
E
REMARKS
F
G
I
J
B577
EMERGENCY LIGHT
10.5
15 PHOTOCELL
45 PHOTOCELL
PHOTOCELL
WALL PACK/CEILING MOUNT
WALL PACK
WALL PACK
16.9
SURFACE MOUNT
SURFACE MOUNT
E
E E
E
E
E
E
E
E
EE
E
G G
J J J J J J
III
S
S
S S
S
S
TS
TS
TS
TS
SS SS SS
TS
TS
S
SS
S
SS
SSS SS S
TS
TS
TS
S
TS
S SSS
S
S
TS
TS
SS
S
S
TS
TS
S SS
F F F F F F
E
E E
E
E
E
E
E E
E
E
E
G G
JJJ JJ J
S
SS
S
S
S S
S
S
SS
TS
TS
TS
TS
S
S
S S
S
S
TS
TS TS
TS
SS SS S SS
TS
TS
S
S
S
S
S
SS
S
TS
TS
F F F F F F
E001
B577 2ND FLOOR LIGHT PLAN
SCALE: 1 : 75E001
E001
J1-00092-4J
LIGHTING FIXTURE SCHEDULE
E001
106 105 104 103 102 101
206 205 204 203 202 201
B577 LIGHT PLAN
3 08
1:75
REPLACE INTERIOR AND EXTERIOR LIGHTS WITH LED
FLUSH MOUNT
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
E
E E
E
E
E
E
E E
E
E
E
E
E E
E
E
E
E
E
E
EE
E
G G
G G
JJJ JJ J
J J J J J J
III
S
S
S S
S
S
TS
TS
TS
TS
SS SS SS
TS
TS
S
SS
S
SS
SSS SS S
TS
TS
TS
S
TS
S SSS
S
S
TS
TS
SS
S
S
TS
TS
S SS
S
SS
S
S
S S
S
S
SS
TS
TS
TS
TS
S
S
S S
S
S
TS
TS TS
TS
SS SS S SS
TS
TS
S
S
S
S
S
SS
S
TS
TS
F F F F F F
F F F F F F
WATTSTYPE EALAMP TYPE
LED
LED
LED
LED
LED
LED
LED
A
B
C
INSTALLATION TYPE
CEILING RECESSED
CEILING RECESSED
LED
E
REMARKS
F
G
I
J
30 9
EMERGENCY LIGHT
10.5
15 PHOTOCELL
45 PHOTOCELL
PHOTOCELL
WALL PACK/CEILING MOUNT
WALL PACK
WALL PACK
16.9
SURFACE MOUNT
SURFACE MOUNT
B578
B578 1ST FLOOR LIGHT PLAN
SCALE: 1 : 75E002
B578 2ND FLOOR LIGHT PLAN
SCALE: 1 : 75E002
E002
J1-00092-4J
LIGHTING FIXTURE SCHEDULE
E002
106 105 104 103 102 101
201202203204205206
B578 LIGHT PLAN
4 08 1:75
FLUSH MOUNT
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
REF REFREF REF REF
E E
S
E E E E E E
EEEEEEEEEE
E
G G G G G
G
G G G G G
G
S S
SS
REF
STS TSS
UP
S S
REF
SS
S
SS
S
STS
S
REF
SS
TS
S
TS TSS
S
SREF
SS
S
S
S
REF
TS S
S
S TS
S
SS
S S
S
DN.
S
TS S
S S
SS
S TS
S
S
DN.
F F F F F
F F F FF
I I
WATTSTYPE EALAMP TYPE
LED
LED
LED
LED
LED
LED
LED
A
B
INSTALLATION TYPE
CEILING RECESSED
CEILING RECESSED
E
REMARKS
F
G
I
30 50
EMERGENCY LIGHT
10.5
15 PHOTOCELL
45 PHOTOCELLWALL PACK/CEILING MOUNT
WALL PACK
D WALL MOUNT
SURFACE MOUNT
SURFACE MOUNT
B579
B579 1ST FLOOR LIGHT PLAN
SCALE: 1 : 75E003
B579 2ND FLOOR LIGHT PLAN
SCALE: 1 : 75E003
E003
J1-00092-4J
LIGHTING FIXTURE SCHEDULE
E003
109 108 107 106 105 110 104 103 102 101
210 209 208 207 206 205 204 203 202 201
B579 LIGHT PLAN
5 08
1:75
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
REF REFREF REF REF
E E
S
E E E E E E
EEEEEEEEEE
E
S S
SS
REF
STS TSS
UP
S S
REF
SS
S
SS
S
STS
S
REF
SS
TS
S
TS TSS
S
SREF
SS
S
S
S
REF
TS S
S
S TS
S
SS
S S
S
DN.
S
TS S
S S
SS
S TS
S
S
DN.
H H H H H
H H H H H
HH
F F F F
F F F F F
I I
WATTSTYPE EALAMP TYPE
LED
LED
LED
LED
LED
LED
LED
A
B
INSTALLATION TYPE
CEILING RECESSED
CEILING RECESSED
E
REMARKS
F
I
30 50
EMERGENCY LIGHT
10.5
40 PHOTOCELL
45 PHOTOCELLWALL PACK/CEILING MOUNT
WALL PACK
D WALL MOUNT
SURFACE MOUNT
SURFACE MOUNT
H
B580
B580 1ST FLOOR LIGHT PLAN
SCALE: 1 : 75E004
B580 2ND FLOOR LIGHT PLAN
SCALE: 1 : 75E004
E004
J1-00092-4J
LIGHTING FIXTURE SCHEDULE
E004
109 108 107 106 105 110 104 103 102 101
210 209 208 207 206 205 204 203 202 201
B580 LIGHT PLAN
6 08
1:75
F
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
REF REFREF REF REF
E E
S
E E E E E E
EEEEEEEEEE
E
S S
SS
REF
STS TSS
UP
S S
REF
SS
S
SS
S
STS
S
REF
SS
TS
S
TS TSS
S
SREF
SS
S
S
S
REF
TS S
S
S TS
S
SS
S S
S
DN.
S
TS S
S S
SS
S TS
S
S
DN.
H H H H H
H H H H H
HH
F F F FF
F F F F F
I I
WATTSTYPE EALAMP TYPE
LED
LED
LED
LED
LED
LED
LED
A
B
INSTALLATION TYPE
CEILING RECESSED
CEILING RECESSED
E
REMARKS
F
I
30 50
EMERGENCY LIGHT
10.5
40 PHOTOCELL
45 PHOTOCELLWALL PACK/CEILING MOUNT
WALL PACK
D WALL MOUNT
SURFACE MOUNT
SURFACE MOUNT
H
B581
B581 1ST FLOOR LIGHT PLAN
SCALE: 1 : 75E005
B581 2ND FLOOR LIGHT PLAN
SCALE: 1 : 75E005
E005
J1-00092-4J
LIGHTING FIXTURE SCHEDULE
E005
109 108 107 106 105 110 104 103 102 101
210 209 208 207 206 205 204 203 202 201
B581 LIGHT PLAN
7 08 1:75
TYPE "A, B" TYPE "C" TYPE "D" TYPE "E"
TYPE "G" TYPE "H" TYPE "I"TYPE "F"
TYPE "J"
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
EQUAL PRODUCTS.
"KIMIN ELECTRONIC, R30TR3U2DU40" OR
LISTED, LED AND CONTROLLER INCLUDED.
4000K, 100/277V, FLUSH MOUNTED TYPE, UL
LED LIGHT FIXUTRE, 30W, 2’ X 2’, 30W,
EQUAL PRODUCTS.
LIGHTING, CWM4-35MLSM-FRFP-EDU" OR
CONTROLLER INCLUDED. "COLUMBIA
RECTILINER LENS, UL LISTED ,LED AND
120-277V, SURFACE MOUNTED, FROSTED
LED LIGHT FIXTURE, 38W, 4’ (L), 3500K,
EQUAL PRODUCTS.
"JUNO, JSBT 4IN 30K 90CRI WL MW" OR
LISTED ,LED AND CONTROLLER INCLUDED.
SURFACE MOUNTED DISK LIGHT, UL
LED LIGHT FIXTURE, 10.5W, 4", 3000K, 120V,
PRODUCTS.
"MAXLITE, SECS15UCSBPC" OR EQUAL
LED AND CONTROLLED INCLUDED.
PHOTOCELL, WALL PACK TYPE, UL LISTED,
120/277V, 5-7/8" (W), 8-5/8" (D), TYPE IV,
LED LIGHT FIXTURE, 15W, 1,900LM,
PRODUCTS.
"MAXLITE, WCOP40U-CSBPC" OR EQUAL
LED AND CONTROLLED INCLUDED.
PHOTOCELL, WALL PACK TYPE, UL LISTED,
120/277V, 7-5/8" (W), 10-3/4" (D), TYPE IV,
LED LIGHT FIXTURE, 40W, 5,450LM,
PRODUCTS.
LIGHTING, P5674030K" OR EQUAL
CONTROLLED INCLUDED. "PROGRESS
WALL CYLINDER, UL LISTED, LED AND
LED LIGHT FIXTURE, 16.9W, 3000K, 120V,
E006
J1-00092-4J
TYPE "B" WITH EMERGENCY BATTERY
TYPE "A" WITHOUT EMERGENCY BATTERY
PRODUCTS.
ELECTRONICS, R30TR3U2DU40" OR EQUAL
AND CONTROLLER INCLUDED. "KIMIN
100/277V, RECESSED TYPE, UL LISTED, LED
LED LIGHT FIXTURE, 30W, 1’ X 4’, 4,000K,
WH M6" OR EQUAL PRODUCTS.
"JUNO, JSF 11IN 13LM 30K 90CRI MVOLT ZT
LISTED ,LED AND CONTROLLER INCLUDED.
120/277V, SURFACE MOUNTED LIGHT, UL
LED LIGHT FIXTURE, 20W, 11", 3000K,
EQUIP WITH PHOTOCELL
1200-LED-4K" OR EQUAL PRODUCTS.
INCLUDED. "WF HARRIS LIGHTING,
MOUNT, UL LISTED, LED AND CONTROLLED
12" (W), 8-13/16" (D), WALL PACK/ CEILING
LED LIGHT FIXTURE, 45W, 4000K, 120/277V,
E006
8 08
LIGHT FIXTURE DETAIL
LIGHT FIXTURE DETAIL
| 580 LIGHT-Default-038 |
| 580 LIGHT-Default-039 |
| 580 LIGHT-Default-040 |
| 580 LIGHT-Default-041 |
| 580 LIGHT-Default-042 |
| 580 LIGHT-Default-043 |
| 580 LIGHT-Default-044 |
| 580 LIGHT-Default-045 |
File details come from the government source that posted it. Updated .