Attachment 1-Drawing.pdf

PDF 598 KB Posted

Attached to
(LCS MATOC) Provide Resilient Wall Coverings in Common Spaces, Bldg 5190, Camp Mujuk
Solicitation number
W90VN924R0097
Issued by

About this file

This document contains the 1st, 2nd, and 3rd floor plans for the Resilient Wall Coverings in Common Spaces, Building 5190 at Camp Mujuk project under Solicitation No. W90VN924R0097. The plans show the architectural layout, including room numbers, dimensions, equipment, and other building details. The related federal contract opportunity is for the "LCS MATOC" program to provide resilient wall coverings in the common spaces of Building 5190 at Camp Mujuk. The solicitation is being issued by the Department of the Army Materiel Command, Army Contracting Command.

View the file

Other files

File Type Posted
RFP LCS W90VN924R0097.pdf PDF
Attachment 2-Contract Implementation Confirmation.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

M

R

A E

F

L X d g n j e d d m k

FAR EAST DISTRICT

R

A E F

L X .d g n

IN

-H

O U

S E

S E

O U

L ,K

O R

E A

U S

A E

D F

E ,E

D ,D

E S

IG

N B

R A

N C

H

F A

R E

A S

T D

IS

T R

IC

T

AE101

S

T

N D F

L O

O R P

L A

N

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

C A

M P M

U J

U K

K O

R E

A

C Y R

O K

F C I

N -K

IN

D P

N M

R

1� ���

2� ���

J .T .Z

K

IM

,M

K

K

IM

,M

K

/0

/2

S O

N T

H A P .E

C H

IE

F

25282

P

N O

P E

N B

A Y B

IL

L E

T

IN

G (1

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

Sheet of

800040000

SCALE: 1:200

GRAPHIC SCALE

LIFE SAFETY REQUIREMENTS PLAN.

1. SEE AE003 LIFE SAFETY PLAN FOR

NOTE:

N

N

FEC FEC

FEC

FEC

FEC

FEC

CONCRETE WALL

FLOOR PLAN LEGEND

DOOR

DRY WALL

CONC/STEEL COLUMN

FNSH SYSTEM

WITH EXTERIOR INSUL

200THK CONC WALL

ROOM NUMBER

WINDOW

AREA CALCULATION

PER DD FORM 1391

AUTHORIZED GROSS AREA: 5,210 M

CALCULATED AS 50% OF ACTUAL AREAS)

(COVERED WASH AREA & STAIRS AREAS ARE

TOTAL - 5,200 M

3RD FLOOR - 1,677.8 M

2ND FLOOR - 1,677.8 M

1ST FLOOR - 1,844.4 M

BUILDING GROSS AREA:

A

B

C

D

THE STANDARD CONVENTION.

1. WALL ELEVATIONS ARE DESIGNATED BY

NOTE

DOOR NUMBER

WINDOW NUMBERW4

D7

METAL SPLASH PAN

CONC SPLASH BLOCK/

KB

SEE DWG AF603

KB (KNOX BOX)

AE401

AE402

AE404

AE403

VVV

UP

REF REF

OA-K

-RJ-

SL-B

K-19

REF

UPUP

1ST FLOOR PLAN

1:200

MECH ROOM

WASH AREA

LAUNDRY

5PN UNIT

5PN UNIT

5PN UNIT

5PN UNIT

5PN UNIT

5PN UNIT

125 126 127

5PN UNIT

5PN UNIT

5PN UNIT

5PN UNIT

5PN UNIT

5PN UNIT

5PN UNIT

5PN UNIT

10PN UNIT

VEST-1

LOBBY

TOILET

BUNK

DUTY

OFFICE

DUTY

CORRIDOR-1 106

ARMS ROOM

CORRIDOR-2 108

STAIR-1

VEST-2

STAIR-2

JC

WT

MT

LOUNGE

OFFICE COMMANDER

COMM

ROOM

ELEC

ROOM

CONFERENCE

SIPRNET

VEST-3

STAIR-3

REF

REF

MW

MW

MW

MW

88850

12 132 3 4 5 6 7 8 9 10 11 14 15 16 17 18 19 20 21 22 23 24

400033503450360047003300460044504450420041005043004200400040004000400040004000400041004000

A

B

C

D

E

5PN UNIT5PN UNIT

CLO

REF

CLO

REF

CLO

REF

CLO

REF

CLO

REF

CLO

REF

CLO

REF

CLO

REF

CLO CLO

CLO

REF

CLO

REF

CLO

REF

CLO

REF

CLO

REF

CLO

REF

CLO

REF

CLO

REF

2D 2D 2D 2D 2D 2D 2D 2D 2D 2D 2D 2D 2D

W

W

W

W

W

2D

W W

W

W W

W

W

W

W

W

W

D7

W4 W4 W4 W4 W4 W4 W4 W4

D6

W1 W3 W4 W5 W5 W5 W5 W4 W3 W2 W1 W1W1W1W1

D31

D30

TD1

TD1

TD1 TD1 TD1 TD1

TD1 TD1 TD1 TD1

TD1

TD1

TD1 TD1

TD1 TD1 TD1

D28

D27

D29

D1

D8

W8

D10

D9

D11

D12 D13

D2

D3

D4

D14

D15D17

D16

D18D19D20D21D22D23D24D25

D26

D5

2D2D2D2D2D2D2D2D2D2D2D2D2D2D2D2D2D2D2D

2D

W

W

W W

W

W

W

W

W

W

W

W

W W

W

W

W

W

W

W

UP DN

V

V

V

V

STAIR-1

CORRIDOR-1 202

50PN OPEN BAY

STAIR-2

30PN OPEN BAY

MT

30PN OPEN BAY

COMM

ROOM

ELEC

208 210

AREA

VENDING

JC

STAIR-3

ROOM

AHU

45PN OPEN BAY

2ND FLOOR PLAN

1:200

UPDN

UP DN

DS

DS

DS

DS

DSEJ EJ

DS

DS

S L

O P

E

SLOPE

2/10

SLOPE

2/10

SLOPE

2/10

SLOPE

2/10

SLOPE

2/10

88850

12 132 3 4 5 6 7 8 9 10 11 14 15 16 17 18 19 20 21 22 23 24

400033503450360047003300460044504450420041005043004200400040004000400040004000400041004000

A

B

C

D

E

REF

REFREFREF

REF

REF

REF REF

CLO CLO CLO CLO CLO CLO REF REF REF CLO CLOCLO CLO CLO CLO REF

REFREFREFREF CLOCLO CLO CLO CLO CLO

REF

REFREF CLO CLO CLO CLO

REF

REFREF REFREF REFCLO CLO CLO CLO CLO

REFREF

REF

CLO

REF

CLO

CLO

CLO

REF

REF

W4

D36

TD1

W4 W4 W4 W4 W4 W4 W4 W4 W4 W4 W4 W4 W4 W5 W5 W5 W6 W7

W4W3 W5 W5 W5 W5 W2 W2 W2 W2 W2 W2 W2

TD1

TD1

TD1

D35 D34

TD1 TD1

D33

TD1

TD1 TD1

TD1

D40

D41

D39

D38

D37 david.hutchinson Rectangle david.hutchinson Polygonal Line david.hutchinson Rectangle david.hutchinson Rectangle david.hutchinson Rectangle david.hutchinson Rectangle david.hutchinson Rectangle david.hutchinson Rectangle david.hutchinson Rectangle david.hutchinson Rectangle david.hutchinson Rectangle david.hutchinson Polygonal Line david.hutchinson Rectangle david.hutchinson Typewritten Text

TYPICAL FLOOR PLANS FOR LSA 1, LSA 2 AND LSA3

R

A E

F

L X d g n j e d d m

FAR EAST DISTRICT

R

A E F

L X .d g n

IN

-H

O U

S E

S E

O U

L ,K

O R

E A

U S

A E

D F

E ,E

D ,D

E S

IG

N B

R A

N C

H

F A

R E

A S

T D

IS

T R

IC

T

AE102

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

R

D F

L O

O R P

L A

N

C A

M P M

U J

U K

K O

R E

A

C Y R

O K

F C I

N -K

IN

D P

N M

R

3� ���

J .T .Z

K

IM

,M

K

K

IM

,M

K

/0

/2

S O

N T

H A P .E

C H

IE

F

25283

P

N O

P E

N B

A Y B

IL

L E

T

IN

G (1

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

Sheet of

800040000

SCALE: 1:200

GRAPHIC SCALE

CONCRETE WALL

FLOOR PLAN LEGEND

DOOR

DRY WALL

CONC/STEEL COLUMN

FNSH SYSTEM

WITH EXTERIOR INSUL

200THK CONC WALL

WINDOW

LIFE SAFETY REQUIREMENTS PLAN.

1. SEE AE003 LIFE SAFETY PLAN FOR

NOTE:

N

FEC FEC

FEC

ROOM NUMBER

A

B

C

D

THE STANDARD CONVENTION.

1. WALL ELEVATIONS ARE DESIGNATED BY

NOTE

DOOR NUMBER

WINDOW NUMBERW4

D7

AE406

AE405

STAIR-1

CORRIDOR-1 302

50PN OPEN BAY

STAIR-2

30PN OPEN BAY

MT

30PN OPEN BAY

COMM

ROOM

ELEC

308 310

AREA

VENDING

JC

STAIR-3

ROOM

AHU

45PN OPEN BAY

3RD FLOOR PLAN

1:200

DN

DN

DN

88850

12 132 3 4 5 6 7 8 9 10 11 14 15 16 17 18 19 20 21 22 23 24

400033503450360047003300460044504450420041005043004200400040004000400040004000400041004000

A

B

C

D

E

REFREFREFREF CLOCLO CLO CLO CLO CLO

REF

REFREF CLO CLO CLO CLO

REF

REFREF

REF

REFREF

REFREFREF CLO CLO CLO CLO CLO CLO

REFREF REFCLO CLO CLO CLO CLO

REF

REF

REF REF REF CLO CLOCLO CLO CLO CLO REF

REF

CLO

REF

CLO

CLO

CLO

REF

REF

V

V

V

V

W5

D45

TD1

W5 W5 W5 W5 W5 W5 W5 W5 W5 W5 W5 W5 W5 W5 W5 W6 W6 W7

W5W4 W5 W6 W6 W6 W4 W4 W4 W4 W4 W4 W4

TD1

TD1

TD1

D44 D43

TD1 TD1

D42

TD1

TD1 TD1

TD1

D49

D50

D48

D47

D46

REF

REF

david.hutchinson Rectangle david.hutchinson Polygonal Line david.hutchinson Rectangle

File details come from the government source that posted it. Updated .