This document is an amendment (Amendment 0001) to a solicitation (Solicitation Number W90VN924R0070) for the repair of deteriorated Barracks, Building 262, at Camp Carroll in Korea. The amendment revises the Statement of Work and associated drawings, extends the due date/time for offers to June 10, 2024 at 1:00 PM, and keeps all other terms and conditions unchanged.
The key details include: the contractor shall repair the deteriorated barracks by performing civil, architectural, fire protection, plumbing, and electrical work; the performance period is 390 calendar days including 120 days for procurement; this is an existing Area IV General Construction MAIDIQ contract; and the site visit is scheduled for May 2, 2024. The revised drawings and scope of work changes are included in the amendment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 1-Drawings for B262 Camp Carroll (Rev1).pdf | ||
| W90VN924R0070.pdf | ||
| Attachment 1-Drawings (HS-00627-0J).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
411TH CSB, KOREA - RCO DAEGU
POC: MS. KWON, CHONG-HYON
TEL: 315-763-5693
CHONGHYON.KWON.LN@ARMY.MIL
APO AP 96218-5682
UNITED STATES
0012105809 HS-00627-0J
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
See next pages.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 7
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 02-Jun-2024
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W90VN924R0070
X 9B. DATED (SEE ITEM 11)
23-Apr-2024
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
03-Jun-2024
CODE
411TH CONTRACTING SUPPORT BRIGADE, KOREA
RCO DAEGU, UNIT #15682
APO AP 96218-5682
UNITED STATES
W90VN9 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE W90VN9
FACILITY CODECODE
EMAIL:TEL:
W90VN924R0070
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by full text:
AMENDMENT 0001
A. The purpose of this amendment 0001 is to revise SOW and drawings as below:
From To
Architectural Work
5.4 Provide individual electric range with oven as
GFCI item at each units.
5.4 provide individual electric range as CFCI item at each units.
5.18 Repair existing unit entrance door. 5.18 Replace existing unit entrance door. *
* Please refer to the revised drawings listed below.
Page No. Sheet ID Changes
46 AD101 DRAWING REVISED, LEGEND DELETE
47 AD102 DRAWING REVISED, LEGEND DELETE
48 AD103 DRAWING REVISED, LEGEND DELETE
50 AD401 DRAWING REVISED, SHEET KEYNOTES 041
DELETE, LEGEND DELETE
52 AE101 DRAWING REVISED, LEGEND DELETE
53 AE102 DRAWING REVISED, LEGEND DELETE
54 AE103 DRAWING REVISED, LEGEND DELETE
65 AE401 DRAWING REVISED, SHHE KEYNOTES 532
DELETE, LEGEND DELETE
100 AE613 DOOR HARDWARE SCHEDULE, HDW-14 REVISD
B. Extend due date/time to 10 June 2024 @ 13:00.
C. All other terms and conditions remain unchanged.
SECTION A - SOLICITATION/CONTRACT FORM
The required response date/time has changed from 21-May-2024 01:00 PM to 10-Jun-2024 01:00 PM.
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been modified:
GENERAL DESCRIPTION OF WORK TO BE COMPLETED
PROJECT NO TITLE LOCATION
HS-00627-0J Repair Deteriorated Barracks, B262 Camp Carroll
DESCRIPTION: The work to be performed shall be in accordance with all drawings and specifications provided under this contract.
a. Work by Contractor:
(1) The contractor shall provide all labor, tools, equipment, supplies and any other resources necessary to accomplish the scope of work contained herein as indicated in the drawings and specifications.
(2) The contractor shall repair deteriorated barracks, B262, Camp Carroll in accordance with the specifications and drawings.
(3) Performance Period: Shall be 390 calendar days, including 120 days for procurement of US origin materials after Notice to Proceed (NTP) is issued.
b. Work by In-House Labor: Not applicable to this project.
c. Work by Troop Labor: Not applicable to this project.
PRINCIPAL FEATURES: This project shall include the following:
General Services:
The contractor shall submit completed material lists and shop drawings to DPW, Engineering Division, Design and Technical Review Branch through the COR.
Schedule #I, Repair/ Maintenance (K): All work shall be in accordance with the attached drawings and specifications.
Civil Work
1. Repair by replacing the existing AC pavement.
2. Repair by replacing the existing concrete curb.
3. Repair by replacing the existing concrete sidewalk.
4. Repair by replacing the existing striping.
5. Repair by replacing the existing handrails.
6. Repair by replacing the existing 0.3m and 0.45m wide concrete ditch with steel gratings.
7. Repair by replacing the existing 0.3m and 0.45m wide concrete ditch w/steel gratings w/new concrete box culvert.
8. Repair by replacing the existing 0.75m wide stone ditch.
9. Repair by replacing the existing 450mm drain lines.
10. Provide ramp w/stainless steel handrails.
11. Provide 150mm post indicator valve w/150mm fire line.
12. Provide 100mm domestic water line.
13. Provide reinforced concrete encasement.
14. Provide concrete encasement.
15. Restore existing surface inlets.
16. Repair by replacing the existing concrete stair.
Architectural Work
1. Floor
1.1 Remove and provide floor finish.
1.2 Remove and provide wall base.
1.3 Clean existing exterior corridor concrete floor.
1.4 Remove and provide concrete slab for plumbing and fire protection scope of work.
2. Wall
2.1 Remove and provide gypsum wall board wall as floor plan indicated.
2.2 Paint interior wall.
2.3 Clean and coating existing exterior insulation and finish system.
2.4 Paint exterior wall and concrete column.
2.5 Provide cement board and metal stud wall between concrete column for exterior duct guide.
3. Ceiling
3.1 Remove and provide ceiling.
3.2 Paint existing concrete ceiling.
3.3 Provide ceiling access door where occur.
4. Roof
4.1 Remove and provide low sloped roofing system with EPDM roofing including insulation.
4.2 Remove and provide mansard clay roof tile and support frame.
4.3 Provide guardrail for fall protection on the roof.
4.4 Remove and provide canopy clay roof tile and support frame.
4.5 Provide steel step on the roof.
5. Miscellaneous
5.1 Remove and provide interior and exterior doors.
5.2 Remove and provide sliding aluminum windows with mini blind for units and common area.
5.3 Remove and provide bathroom fixtures, cabinetry and mirrors at each units.
5.4 Provide individual electric range as GFCI item at each units.
5.5 Provide microwave oven as GFCI item at each units.
5.6 Remove and provide guardrails and handrails at interior and exterior stair.
5.7 Remove and provide non-slip at interior and exterior stairs.
5.8 Remove and provide bulk storage cage.
5.9 Remove and provide concrete splash block.
5.10 Remove and provide protected metal gutter, gutter expansion joint and downspout.
5.11 Remove and provide roof scuttle and new steel ladder.
5.12 Remove and provide fire extinguisher cabinet at exterior corridor.
5.13 Provide emergency key box near entrance.
5.14 Provide chain link fence and chain link fence door for DOAS equipment.
5.15 Provide steel framed duct cover at exterior wall.
5.16 Remove and provide steel steps on the roof.
5.17 Clean and polish existing stainless-steel guardrail at exterior corridor.
5.18 Repair existing unit entrance door.
Fire Protection Work
1. Provide Knox box adjacent to the main entrance.
2. Provide new wet pipe fire sprinkler system including alarm check valve assembly, back flow preventer assembly, sprinkler heads, piping, valves, tamper switches, floor control assembly, test header, fire department connection and all necessary accessories and parts.
(The fire sprinkler routing and pipe sizes indicated in this drawing are at conceptual level. The contractor shall submit the detailed shop drawing(s) and design analysis with FPE's (Fire Protection Engineer) stamp in accordance with applicable codes and regulation prior to construction for approval from DPW and Fire Department. The contractor bears the full responsibility for respective costs in meeting these codes and associated regulations.
Therefore, the contractor is responsible for all other additional cost cause from not shown or/and indicated in the conceptual drawings to meet with applicable codes and regulation to complete subject project construction.)
3. Replace existing fire alarm/ mass notification system.
Plumbing Work
1. Replace existing deteriorated plumbing system including plumbing fixtures, domestic water piping, sewer and vent piping, re-circulation pump, electric water cooler, pump, backflow preventer, water meter, wall hydrant, valves, gauges, water hammer arresters, insulation, washer service boxes, floor clean out, floor drains, access doors and all necessary accessories and parts.
Mechanical Work
1. Remov1e existing deteriorated HVAC system including wall-thru heat pump units, exhaust fans, unit heaters, range hoods, dryer vents, duct works, condensate drainpipe, insulation and all associated accessories and parts.
2. Provide new heating and cooling system including heat pump units, in-wall dehumidifiers, electric unit heaters, control panel, controllers, thermostats, emergency shut-off switches, refrigerant pipe, pipe cover enclosures, condensate drainpipe, insulation, insulation jacketing, stainless steel wire-mesh, access doors, concrete pads, concrete splash blocks, and all associated accessories and parts.
3. Provide new ventilation system including dedicated outdoor air supply unit, exhaust fans, radon, exhaust fans, range hoods, dryer vents, duct work, roof gooseneck, control panel, diffusers, registers, dampers, controllers, thermostats, emergency shut-off switches, insulation, access doors, concrete pads, concrete splash block and all necessary accessories and parts.
Electrical work
1. Replace lights with Led lights.
2. EM unit must be provided in the indicated lighting fixtures.
3. Replace light switches with light switches in accordance with the building renovation.
4. Modify existing panelboards of branch circuits for mechanical and architecture equipment, receptacles, etc.
5. Replace power connection wires with connection wires in accordance with replacement of mechanical equipment.
6. Replace damaged panelboards, safety switches, etc. with panelboards, safety switches and wiring in accordance with the building renovation.
7. Existing CCTV system to remain but remove and reinstall CCTV camera. But clean and test the CCTV camera prior to reinstallation.
8. Replace existing all utility wall faceplate cover with new ones.
Schedule #II, General Requirements: All work shall be in accordance with the attached drawings and specifications.
Civil Work
1. See General Notes, Utility Notes, Grading Notes, and Demolition Notes.
Architectural Work
1. See general requirements on drawing Ref. No. A001
Fire Protection Work
1. See General Construction Notes On Drawing Ref. No. F-001
Plumbing Work
1. See General Notes on Drawing Ref. No. P-001.
Mechanical Work
1. See General Mechanical Notes on Drawing Ref. No. M-001
SECTION J - LIST OF DOCUMENTS, EXHIBITS AND OTHER ATTACHMENTS
The below Table of Contents has been added
Exhibit/Attachment Table of Contents
DOCUMENT TYPE DESCRIPTION PAGES DATE
Attachment 1 Drawings for B262, Camp
Carroll (Rev1)
(End of Summary of Changes)