Text version

ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br

ELECTRICAL

KIM, CK

AS SHOWN

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

UNITED STATES ARMY GARRISION DAEGU

DIRECTORATE OF PUBLIC WORK

UNIT #15746, APO AP 96218-5746

DATE:

N

SHEET OF

N O T E S

CAULKING MATERIAL SHALL BE VERIFIED BY F&ES OFFICE PRIOR TO CONSTRUCTION.

BOTH SIDE OF FIRE WALLS, FIRE-PARTITIONS AND FIRE-RATED PIPE CHASE WALLS.

ALL PIPE PENETRATIONS SHALL BE SEALED WITH FIRE RATED CAULKING MATERIAL ON

1.

SPECIFICATIONS FOR O&MA PROJECTS, AND SPECIFICATIONS.

ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE, FIRE CODE, TECHNICAL STANDARD

ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE NATIONAL

L E G E N D

NEWEXSTREMOVE

+ WIRING CONCEALED IN UNDERGROUND

HOMERUN CIRCUIT TO PANELBOARD OR ENCLOSURE

SCOPE OF WORK

3.

S

27 JUN 19

CAMP WALKER

E-1

J1-00523-5J D - 19 - 11

SCALE : 1 / 300- E1

P-1

1.

2.

3.

B. REPAIR/MAINTENANCE

CHANGES SHALL BE APPRPVED BY THE CONTRACTING OFFICE.

BE RESPONSIBLE TO RESIZE AND PROVIDE THE REQUIRED WIRING AND OVER CURRENT DEVICES. THE

IF EQUIPMENT OTHER THAN INDICATED ON THE PLANS ARE PROVIDED, THEN THE CONTRACTOR SHALL4.

CONTRACTOR SHALL COORDINATE WITH AREA DPW, SIGNAL BRIGADE, CATV BEFORE CONSTRUCTION.

AND ASSOCIATED ACCESSORIES.

REMOVE EXISTING CONCRETE POLE INCLUDING SECONDARY POWER LINES, CATV LINES, LIGHTING FIXTURES

5.

UNIT THRU COR.

REMOVE EXISTING CCTV CAMERAS, WIRING WITH ASSOCIATED ACCESSORIES AND TURN IN TO RELEVANT

4. REMOVE EXISTING COMMUNICATION PEDESTAL AND SPLICE EXISTING COMMUNICATION CABLE.

OVERHEAD SECONDARY LINE

OVERHEAD CATVCATV CATV CATV

1.

A. CONSTRUCTION

CONTROL, WIRING AND NECESSARY ACCESSORIES.

INSTALL NEW LED ROADWAY LIGHTING FIXTURES INCLUDING LIGHTING POLE, LIGHTING CONTACTOR, PHOTOCELL

REMOVAL ELECTRICAL SITE PLAN

NOTES AND SCOPE OF WORKS

REMOVAL ELECTRICAL SITE PLAN, LEGEND,

SIN, YS

91.051

BUILD

89.806

FENCE

91.377

SWALK

SWALK

SWALK

93.022

PARKING

93.293

PARKING

90.042

WALL

93.838

POL

S-244

93.325

AC

93.836

AC

TREE

S-245

S-248

S-246

S-227

S-221

S-228

S -2

LP

EP

EP

EP

EP

EP

EP

EP

EP EP EP

EP

EP

CATV

C A T V

LATERIAL FOR B#244.

DISCONNECT EXISTING SERVICE

1031-1036

CAN(TYPICAL)

AND INSTALL 600PAIRS SPLICE

REMOVE EXISTING PEDESTAL

CAMERA(TYP. OF 2EA)

REMOVE EXISTING CCTV

WITH LIGHTING FIXTURES

REMOVE EXISTING CONCRETE POLEEP

SECONDARY LINES 4-#2 AWG

REMOVE EXISTING OVERHEAD

S

S S

S

S

SS

SS

S ANTE

NNA

LP

R

R C

A T V

SECONDARY LINES 4-#2 AWG

REMOVE EXISTING OVERHEAD

SECONDARY LINES 2-#8 AWG

REMOVE EXISTING OVERHEAD

SECONDARY LINES 4-#6 AWG

REMOVE EXISTING OVERHEAD

LP

EP

3P-225KVA, 208/ 120V

EXISTING TRANSFORMER

EP

SCALE: 1 : 300

GRAPHIC SCALE

0 6000 12000

EP

WP

WP

LPLP

LP

LP

LP

EP

E

T

T

E

T

E

TR

PIV

W/V

FHT

S/P

S/PS/P S/P

G S/P

S/P

S/P

S/P

D

S

S/P S/P S/P

S

S/P

S/P

S/P

S/P

S/P

S/P

S

S/P

S/P

S

D

D D

D D

D

S

S

S

S/P

S/P

S/P S/P

S/P S/P

S/P S/P

S

CONTAINER

C O

N T

A

IN

E R

T

R

EP

C A T V

C A T V

C A T V

C A T V

BURIED CABLE 600PAIRS

ABANDON EXISTING DIRECT

WP

P A

/////PA PA PA OVERHEAD PA & CCTV CABLE

ON B#230, APPROX-10m

FROM EXISTING TAP

4EA COAXIAL CABLE, APPROX-40m

FROM EXISTING GYM B#261

2-#8 WP, APPROX-30m

FROM EXISTING CONCRETE POLE

PHOTOCELL SWITCH

EXISTING LIGHTING CONTACTOR AND

R

R LIGHTING FIXTURE 1/ 107W

EXISTING STEEL POLE AND LED

AND S-246 TO TENNIS COURT

CONVERT BLDG. NO. S-244

26 28

WITH COR CAREFULLY TO DETERMINE PROPER MATERIAL HANDLING METHODS.

CONTRACTOR SHOULD COORDINATE ANY SALVAGEABLE/RECYCLABLE MATERIALS WITHIN PROJECT LIMIT

RG-11U

REMOVE EXISTING CATV LINE

LIGHTING POWER LINE, LIGHTING FIXTURE, ANTENNA, ANTENNA CABLE AND NECESSARY ACCESSORIES.

REROUTE EXISTING OVERHEAD SECONDARY POWER LINES, CATV LINE, AMPLIFIER, UNDERGROUND

KIM, CK

AS SHOWN

HGFEDCBA

DESIGNED BY

CHECKED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

UNITED STATES ARMY GARRISION DAEGU

DIRECTORATE OF PUBLIC WORK

UNIT #15746, APO AP 96218-5746

DATE:

N

SHEET OF

S

27 JUN 19

CAMP WALKER

E-2

J1-00523-5J D - 19 - 11

SCALE : 1 / 300- E2

P-1

SIN, YS

SCALE: 1 : 300

GRAPHIC SCALE

0 6000 12000

E

T

T

T

E

T

NEW ELECTRICAL SITE PLAN

DETAIL

FEATURES

GENERAL DESCRIPTION

6mm

DIA

m m

NOM. DIMENSIONS 838mm Lx330mm Wx190mm D m m

600mm

1/107W LED

1A

1B

GROUND ROD

SEE

CONCRETE BASE

#6 BC (G) IN 22mm C

EXOTHERMIC WELD

LED 120V LAMP, SEE

FIXTURE, W/ 107 W,

TYPE "XL-A" LIGHTING

WIND VELOCITY

7600mm HT, 112 MPH

BRONZE FINISH,

GROUND LUG DARK

NUT COVERS STANDARD

STEEL BASE PLATE

SIZE 127mm, SLOTTED

STEEL POLE, SHAFT

ROUND STRAIGHT

1B

E-2

1A

E-2

TYPE "XL-A"

OTHER: UL LISTED FOR WET LOCATION

FUSE: PROVIDE IN-LINE FUSE FOR EACH FIXTURE.

DARK BRONZE FINISH.

DOOR FRAMES, POLE & BASE TO BE

FINISH: FIXTURE MOUNTING ARM, HOUSING,

METAL-CORE CIRCUIT BOARD.

HIGH-EFFICACY LEDs MOUNTED TO A

ELECTRICAL: TWO LIGHT ENGINES CONSIST OF

ANCHOR BOLTS & MOUNTING HARDWARE

POLE WITH ANCHOR TYPE BASE,

MOUNTING: SQ. EXTRUDED MOUNTING ARM AND

COOLING.

THROUGH CONDUCTIVE & CONVECTIVE

FINS TO OPTIMIZE THERMAL MANAGEMENT

HOUSING WITH INTEGRAL HEAT SINK

HOUSING: SINGLE-PIECE DIE-CAST ALUMINUM

OTHER: TYPE III DISTRIBUTION

DRIVER: CLASS 1 ELECTRONIC DRIVER,

SHIELDING: PRECISION-MOLDED ACRYLIC LENSES

PROFILE: 1 LAMP

LAMP TYPE: 107W LED (TYPE "XL-A" )

POLE MTD LED DETAL

HANDHOLE

500x500x20

BASE PLATE

NON-SHRINK GROUT

25THK

@ 300mm

BARS & D10 TIES

W/ 8-D19 VERTICAL

PEDESTAL 600mm DIA

BY MANUFACTURER

RECOMMENDED

SHALL BE AS

ANCHOR BOLT

T

3P-225KVA, 208/ 120V

EXISTING TRANSFORMER

EP

RR

EP

LP

EP

EP

EP

ANTE

NNA

REMOVE/REINSTALL EXISTING ANTENNA CABLE

RR

NEW 4-#6 AWG "WP"

RR

C A T V

EP

EP

CATV

WP WP

LP

2/107W LED

TYPE "XL-B"

SEE DETAIL

2-#10 AWG, 1-#10(G) IN 22mmC

DROP 4-#8 "WP" AND NEW CATV CABLE

REMOVE/ REINSTALL EXISTING SERVICE

2-#10 "THW" IN 22mmC

EP

ON B#230, APPROX-10m

FROM EXISTING TAP

C A

TV

2-#8 WP, APPROX-30m

REMOVE AND REINSTALL

REMOVE AND REINSTALL 2-#8 WP

NEW 2-#8 WP

- E3

D-1

- E3

D-2

SEE DETAIL

LED ROADWAY LIGHTING

NEW POLE MOUNTED TYPE

- E2

D-1

- E2

D-1

NOT TO SCALE

ROADWAY LIGHT POLE W/FIXTURE DETAIL

WITH NEW 1PH, 120V, 600W

REPLACE EXISTING PHOTOCELL

NEW LED LIGHTING FIXTURE 3EA-180W-208V WITH

BRACKET(GFM) (TYP. OF 4SET)

LIGHTING FIXTURE 120V, 100W(TYP. OF 3EA)

REINSTALL EXISTING REMOVED LED

S-227

S-221

S -2

STOPSTOP

C

SM

G C

C

SM

G C

FIRE LANE

1,200

N O P

A R

K

IN

G

V

IP

V

IP

FIRE LANE

PILOT LAMP NEMA 3, ENCL.

HAND-OFF-AUTO SELECTOR SWITCH WITH

CONTACTOR, 1P-120V, NEMA SIZE 00,

REPLACE EXISTING WITH NEW LIGHTING

E/P

S/P

S/P

S/P

S/P

S/P

T

S/P

SEE DETAIL

CONCRETE ENCASE DUCT

2-#10 AWG, 1-#10(G) IN 22mmC

AND S-246 TO TENNIS COURT

CONVERT BLDG. NO. S-244

27 28

ROADWAY LIGHT POLE W/ FIXTURE DETAIL

POLE MTD LED DETAIL,

NEW ELECTRICAL SITE PLAN,

C A T V

C A T

V

NEW CATV CABLE RG-11U

WITH STEEL WIRE 30mm

REPLACE EXISTING OUTDOOR AMPLIFIER,

WITH NEW TRIPLE OUTPUT TYPE AT BACK

SIDE B#261

NEW CATV CABLE 2SET OF RG-11U WITH

STEEL WIRE 30mm, APPROX-30M FROM

NEAREST TAP POINT BACK SIDE B#261

C A T V

NEW CATV CABLE RG-11U

WITH STEEL WIRE 30mm

NEW CATV CABLE RG-11U

WITH STEEL WIRE 30mm

REINSTALL REMOVED EXISTING CONCRETE POLE

12M WITH NEW GROUND ROD 3M, WIRE #6 "BC"AND

(TYP. OF 4SET)

POWER LINE 4-#8 "THW" IN 28mmC, GROUND ROD 3M, WIRE #6 "BC"

TIMER SWITCH, PILOT LAMP, NEMA 3R ENCL. AND SERVICE

STARTOR 2P-30A C/B, COIL VOLTAGE 208V, NEMA SIZE 0, 2HRS

FOR RECEPTACLES AND COMBINATION TYPE MAGNETIC MOTOR

NEW INCLOSED CIRCUIT BREAKER 1P-20A NEMA 3R

2-#10 "THW" & 1-#10(G) IN 22mmC

2-#12 "THW" & 1-#12(G) IN 22mmC

2-#10 "THW" & 1-#10(G) IN 22mmC

KIM, CK

AS SHOWN

HGFEDCBA

DESIGNED BY

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :SAFETY REP

SIGNAL REP

FES

FORCE PROTECTION

CHIEF,

DESIGN & TECH. REVIEW Br.

O & M

HOUSING DIV.

REVIEWED BY

SYMBOL BY CHK.ZONE DATE APVD.

R E V I S I O N S

DESCRIPTION

UNITED STATES ARMY GARRISION DAEGU

DIRECTORATE OF PUBLIC WORK

UNIT #15746, APO AP 96218-5746

DATE:

SHEET OF

SAND CUSHION

WIDTH VARIES

WARNING TAPE

BACKFILL

COMPACTED

AS INDICATED

AND QUANTITY

CONDUCTOR SIZE

CONDUIT WITH

GRADE

FINISHED

76 76

1 1

OF 100% MAX DENSITY

COMPACTED TO A MIN

SUBBASE COURSE

WARNING TAPE

COMPACTED BACKFILL

BASE

SUBBASE

100% MAX DENSITY

COMPACTED TO A MIN OF

AGGREGATE BASE COURSE

COHESIONLESS MATERIAL

95% OF MAX DENSITY FOR

FOR COHESIVE MATERIAL &

A MIN OF 90% OF MAX DENSITY

OF ALL SUBGRADE CUTS TO

COMPACT THE TOP 152mm

INDICATED CIVIL DWG

(OR PCC PAVEMENT), SEE AS

AC SURFACE COURSE

SIZE AND QUANTITY AS INDICATED

CONDUIT WITH CONDUCTOR

CONCRETE ENCASED DUCT 1 WAY,

CAMP WALKER

E-3

D - 19 - 11

NOT TO SCALE

DUCT SECTION (TRAFFIC AREA)

- E3

D-2

NOT TO SCALE- E3

D-1 DUCT SECTION (NON-TRAFFIC AREA)

DUCT SECTION

SIN, YS

CHECKED BY

27 JUN 19

J1-00523-5J

AND S-246 TO TENNIS COURT

CONVERT BLDG. NO. S-244

28 28

J1-00523-5J_T01
J1-00523-5J_C01
J1-00523-5J_C02
J1-00523-5J_C03
J1-00523-5J_C04
J1-00523-5J_C05
J1-00523-5J_C06
J1-00523-5J_C07
J1-00523-5J_C08
J1-00523-5J_C09
J1-00523-5J_C10
J1-00523-5J_C11
J1-00523-5J_C12
J1-00523-5J_C13
J1-00523-5J_C14
J1-00523-5J_C15
J1-00523-5J_C16
J1-00523-5J_C17
J1-00523-5J_C18
J1-00523-5J_C19
J1-00523-5J_C20
J1-00523-5J_AE01
J1-00523-5J_AE02
J1-00523-5J_AE03
J1-00523-5J_M01
J1-00523-5J_M02
J1-00523-5J_E01
J1-00523-5J_E02
J1-00523-5J_E03