Contractor questions and answers:

1. Is this an interior or exterior type box?

----> Exterior Type Box

2. Are the condenser unit's interior or exterior?

------> Exterior

3. Two floor types are specified, please identify?

--------> It is not two, but one. Stainless Steel Diamond Tread STS304 Type and #16Gauge (thk)

4. Identify what "door accessories' are required?

-------> Door Latch and Door Lock Set

5. Specifications for both 'evaporator coil' and 'condensing unit' sizing needs to be verified.

--------> 1. Evaporator Coil: 4'L X 22"H X 16"D

2. Condensing Unit: 4'L X 28"W X 24"H

6. Need local address and postal code?

--------> No local address and postal code for Pier #8, Busan

Contractor is required to deliver them to DPW, Bldg #2610 (Seamen's Club), Pier #8 City: Busan Zip Code: 96284-5748

7. Is this intended to be a one-piece pre-fabricated box, or is assembly on-site an option?

------> Contractor needs to assemble pre-fabricated parts on-site