W90VN9-24-R-0142_Drawings.pdf
PDF 3 MB Posted
- Solicitation number
- W90VN9-24-R-0142
About this file
This document appears to be a set of technical drawings and specifications related to a federal contract opportunity for the "Separation of Storm and Sewer Line at AFH Tower #2, Camp Walker".
The key details are:
- This is a non-work plan task order Request for Proposal (RFP) under an existing MATOC contract for Area IV contractors only.
- The estimated price range is between $25,000 and $100,000.
- A site visit is required for offerors who intend to propose.
- Proposals must be submitted by 1300 KST on the closing date via email.
- The scope of work includes replacing existing storm and sewer lines, concrete pavement, curbs, and sidewalks at AFH Tower #2 in Camp Walker.
- The government agency involved is the Department of the Army Materiel Command Army Contracting Command.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W90VN9-24-R-0142 Released.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
R-11SHEET OF
DESIGNED BY
CHECKED BY
SUBMITTED BY
APPROVED BY
PROJECT NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
O & M
HOUSING DIV.
REVIEWED BY
UNITED STATES ARMY GARRISON DAEGU
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
DIRECTORATE OF PUBLIC WORK
HGFEDCBA
D - 24 - 28
CHON, HYON TAE
DESIGN REVIEW SIGNATURE
ORGANIZATION
USING AGENCY
36TH SIGNAL
MASTER PLN.
ENVIRONMENTAL
NAME SIGNATURE
O&M DIV.
FIRE DEPT.
SAFETY OFFICE
DPTMS(AT/FP)
188TH MP COM.
IND. HYGENIST
UNIT #15746, APO AP 96218-5746
DRAWING NO.
CHIEF,
DESIGN & TECH. REVIEW Br.
AS SHOWN
1 1 OF 1R - 1
T I T L E S H E E T
TITLE SHEET
USING AGENCY
DATE:11 JUN 24
JA-00027-4J
PROJECT NO. JA-00027-4J, CAMP WALKER
C - 3
C - 4
C - 5
LOCATION PLAN
CAMP WALKER
CIVIL
C - 1
C - 2
C - 6
E - 1
E - 2
SITE LAYOUT PLAN
AT AFH TOWER 2
SEPARATION OF STORM AND SEWER LINE
AT AFH TOWER #2
SEPARATION OF STORM AND SEWER LINE
ELECTRICAL
LEGEND, NOTES AND SCOPE OF WORK
REMOVAL PLAN
SEWER LINE PROFILE
LIFT STATION DETAILS
ASPHALT CONCRETE PAVEMENT, CONCRETE PROTECTION SLAB AND CONCRETE SIDEWALK DETAILS
NEW PUMP CONTROL POWER PLAN AND PUMP CONTROL INSTALLATION DETAIL
AT AFH TOWER #2
SEPARATION OF STORM AND SEWER LINE
LOCATION PLAN
PARK, WON CHAE
CHI, K.K.
11 JUN 24
JA-00027-4J
AS SHOWN 1 8
D - 24 - 28
CAMP WALKER
CIVIL
THIS PROJECT
SEE SITE PLANS
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SCALE : 1 / 3000
GRAPHIC SCALE
(IN METERS)
0 60 120
N
SCALE: 1 : 3000
LOCATION PLAN
STOP
E
E
S
S
S
S-398
S-363
S-373S-372 S-367
S-409
T-392T-391T-390
T-235 Golf Course
S-468
T-445
S
T-444
S
S
T 9 S-470
S-457 T-465
T-466
S-450T-706
S-324
S-422
S-335
S-320
S-338
S-200
S-216T-213
S-452
T-720T-721
T-235 Golf Course
T-235 Golf Course
GATE 6
S-403
TMP Washrack
188TH MP
S-431
S-430
T-433
S-441
GOLAN 10
T-442
S-414
S-411
S -416S
-410
T
S-440
S-711
T-712
S-358
S-349
S-408 T-421
S -420
T-342
T-387
S-701
S-348
T-235 Golf Course
KELLY FIELD
S-252
S-283
S
S-205
S-208
S-261
S
S-260
S-202
S-217
S-212
S
S-222
S-382
S-362
T
T
S-360
S-368
S-386
S-38
T-235 Golf Course
S-2
S-
S-148
S-149 S-163
T-164
S-165
S-166
S-565
S
S
S-161
T-158
S-617
S-57
S-57
S-574
S-556
S
S 1S-566
T-569
S-57
S-57
S-584
T-614
S
S -602
S-601
S
S
S
S
S-
S- 2S-221
T-573
S
S-267
S
S-314
S-303
S-304
S-305
S-309
S-327
S-328
S-334
S-312
S-318
S
S-592
T-594
S
S
S-379
S-374
T
S-310
T-340
S-330
T-341
SUBSTATION
MIDDLE / HIGH SCHOOL
S-321
S-359
GATE 4
S-393
APSAN OVERPASS BRIDGE
APSAN OVERPASS BRIDGE
S-357
T-364
S-356
T-355
S-353 S-399
S-350
S-352
S-344 tank-1 water tank-2 water
STREET
WASHINGTON
S-556
S-
S-5
S-585
S
S
S
S
S-315
S
S-226
S-316
S
S
S
S-237
CDC
S-
S-
S-
S
S-182 S-555
S-557
S-228
S-230
S-227
S-616
P A R
K
IN
G
S T R
U C T U
R E
P A R
K
IN
G
S T R
U C T U
R E
TOWER 2
FAMILY HOUSING
P A R
K
IN
G
S T R
U C T U
R E
TOWER 3
FAMILY HOUSING
P A R
K
IN
G
S T R
U C T U
R E
T O
W E
R
F A
M
IL
Y
H O
U S
IN
G
T O
W E
R
F A
M
IL
Y
H
U S
IN
G
LOT
PARKING
LATRINE
S-265
(U N
D E
R
C
N S T R
U C
T
IO
N
L O
D G
E
S-232
S-250
POND
C-1
AC.
AC.
AC.
AC.
AC.
AC.
AC.
AC.
AC.
AC.
CURB.
CURB.
CURB.
SW.
IN
LET.
IN
LET.
L/ P.
L/ S.
L/ S.
C/ G.
C/ G.
0.
CL.
CL.
CL
S/ P.
.42
.54
.62
.59
.58
.15
.21
.23
.14
.06
.93
.01
.39
.65
.76
.60
.57
.18
.88
.91
.59
.64
.93
.18
.19
.24
.20
E
D
S
S
L/P
L/P
L/P
L/P
S/P
S
SCALE : 1 / 150
(BLDG. # S-810)
FAMILY HOUSING TOWER #2
~A.C.~
~A.C.~
S
ID
E W
A L K
SCO : SURFACE CLEANOUT
L/P : LIGHTING POLE
S/P : SIGN AND POST
AC : ASPHALT CONCRETE
SCO
SCO
SCO
SCO
SCO
SCO
N
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
GRAPHIC SCALE
SCALE: 1 : 150
3000 6000
ABBREVIATIONS:
TO BE REPLACED
EXISTING ASPHALT CONCRETE PAVEMENT
TO BE RESTORED
EXISTING CONCRETE CURB AND GUTTER
TO BE REPLACED
EXISTING CONCRETE SIDEWALK
TO BE RESTORED
EXISTING CONCRETE CURB INLET
CUT AND PLUG
REMOVE EXISTING SEWER LINES,
REMOVAL PLAN
(PVC, D=150, ASSUMED)
EXST. DRAIN LINE
TO REMAIN
EXSTING LIFT STATION
PROJECT WORK LIMIT
TO BE RESTORED
EXISTING PAVEMENT MARKINGS
TO BE RESTORED
EXISTING CONCRETE DRAIN MANHOLE
AT AFH TOWER #2
SEPARATION OF STORM AND SEWER LINE
REMOVAL PLAN
PARK, WON CHAE
CHI, K.K.
11 JUN 24
JA-00027-4J
AS SHOWN 2 8
D - 24 - 28
C-2
CAMP WALKER
CIVIL
4.
5.
6.
7.
E
S
S
(RCP, D=450)
STST
(R C P D
S T
(R
CP
, D
0)
ST
ST
ST
(PVC, D=75, ASSUMED)
(R C
P
D
S T
S
14.
13.
12.
15.
16.
GENERAL NOTES:
ENVIRONMENTAL GOVERNING STANDARD(EGS) CHAPTER 5 & CHAPTER 6.
CODE OF REGULATION 1910 SUBPART H AND USFK REGULATION 201-1,
DURING THE PROJECT MUST BE STORED IN ACCORADANCE WITH THE
ALL HAZARDOUS MATERAIL AND HAZARDOUS WASTE USED/ CREATED
1.
OF CONTRACT PROPOSAL.
DIMENSIONS AT THE PROJECT SITE ORIENTATION PRIOR TO SUBMISSION
THE CONTRACTOR SHOULD VERIFY ALL EXISTING CONDITIONS AND
2.
3.
4.
5.
6.
7.
CONTRACTING OFFICER PRIOR TO COMMENCING WORK ON THE PROJECT.
OF THE JOB BY THE COR AND SHOULD BE APPROVED BY THE
THE CONTRACTOR SHOULD SUBMIT SHOP DRAWINGS FOR ANY PORTION
WHICH WILL INTERFERE WITH THE CONSTRUCTION OPERATIONS.
UNDERGROUND ROCK BASE, EXISTING UTILITY LINES, AND OTHER ITEM
CLEARED/REROUTED OF ALL NATURAL OBSTRUCTIONS, SUCH AS
THE SITE INDICATED ON THE DRAWING SHOULD BE GRADED AND
8.
9.
10.
11.
GOVERNMENT.
LAY DOWN AREA SHALL BE PROVIDED FOR THE CONTRACTOR BY THE
STORAGE AREAS SHALL BE WITHIN THE CONSTRUCTION AREA AND NO
APPROVED/INDICATED BY C.O.R. ADMINISTRATIVE FIELD OFFICES AND
TEMPORARY FACILITIES ACCORDING TO O&MA SPEC. AT THE LOCATION
CONTRACTOR SHOULD PROVIDE AND MAINTAIN THE CONTRACTOR’S
AND STATIONS AND ELEVATIONS ARE IN METERS.
UNLESS OTHERWISE NOTED ALL THE DIMENSIONS ARE IN MILLIMETERS
SATISFACTION OF THE CONTRACTING OFFICER.
DEMOLISHING, OR REMOVING AT THE CONTRACTORS EXPENSE TO THE
TO THEIR ORIGINAL CONDITIONS OF THE ITEMS DAMAGED BY DISMANTLING,
THE CONTRACTOR SHOULD BE RESPONSIBLE FOR REPAIR/RESTORATION
ROAD FOR VEHICLES DURING CONSTRUCTION PERIOD IF REQUIRED.
CONTRACTOR SHOULD PROVIDE TEMPORARY ACCESS ROAD AND DETOUR
OTHER UTILITY MARKERS IN THE PROJECT LIMIT.
CONTRACTOR SHALL RESTORE/REESTABLISH SURVEY MONUMENTS AND
UTILIZED TO ACCOMPLISH THE CIVIL SCOPE OF WORK.
COMMAND" FORM AS A PART OF THIS PROJECT.THE DETAILS WILL BE
OCTOBER 2015, DEPARTMENT OF THE ARMY INSTALLATION MANAGEMENT
TECHNICAL SPECIFICATIONS FOR O & MA PROJECT, KOREA, REVISION1, 30
OF THE ARMY INSTALLATION MANAGEMENT COMMAND" AND "STANDARD
DRAWINGS, FOR O & MA PROJECT, KOREA, 30 NOVEMBER 2015, DEPARTMENT
THE CIVIL STANDARD DRAWINGS SHOWN IN THE "STANDARD DETAIL
DEPTH UNLESS OTHERWISE NOTED.
WATER AND SEWER LINE SHOULD HAVE A MINIMUM COVER OF FROST
ADDITIONAL COST.
FALSEWORK SUCH AS FORMWORKS AND SHORING WITHOUT ANY
CONTRACTOR SHOULD PROVIDE ANY NECESSARY RESOURCES INCLUDING
LEASED PROPERTY IN ACCORDANCE WITH LOCAL LAWS AND REGULATIONS.
DISPOSAL OF WASTE MATERIALS SHOULD BE OUTSIDE U.S.GOVERNMENT
TO COMMENCING THE WORK.
TO THE DESIGN AND TECHNICAL REVIEW BRANCH FOR APPROVAL PRIOR
THE CONTRACTOR SHOULD PREPARE AND SUBMIT MATERIAL SUBMITTAL
TRAFFIC AND OPERATIONS.
FOR THE PROTECTION AND SAFETY OF THE PUBLIC AND/OR MILITARY
PROTECTIVE FACILITIES AND SHALL TAKE ALL NECESSARY PRECAUTIONS
SIGNS, LIGHTS, FLARES, BARRICADES, MARKERS, CONES AND OTHER
CONTRACTOR SHALL PROVIDE, INSTALL AND MAINTAIN ALL NECESSARY
SODDING WITHIN THE WORK BOUNDARY.
CUT AND FILLED AREA SHALL BE COVERED WITH TOP SOIL AND SOLID
17.
REMOVAL NOTES:
1.
2.
3.
INDICATED, UNLESS OTHERWISE NOTED.
ALL REMOVAL WORKS SHALL BE CONFINED WITHIN THE PROJECT LIMITS
INDICATED AND REQUIRED.
THE ITEMS WITHIN THE PROJECT BOUNDARY SHALL BE REMOVED AS
CHAIN-LINK FENCE, ETC.
THE PROJECT LIMITS, I.E. EDGE OF PAVEMENT, EDGE OF ROADWAY, EXISTING
EXISTING GROUND FEATURES SHALL BE USED AS A DEMARCATION FOR
PAM 200-1.
KOREAN ENVIRONMENTAL GOVERNING STANDARDS FOR KOREA, USFK
ALL DISPOSAL WORK SHALL BE IN ACCORDANCE WITH THE APPLICABLE
THE USFK REGULATION 201-1, TABLE 2-7 (DUST REDUCTION REQUIREMENTS).
THE CONTRACTOR SHALL PERFORM THE WORKS IN ACCORDANCE WITH
IMMEDIATELY TO ITS ORIGINAL OR BETTER CONDITIONS.
RESULT OF THE CONSTRUCTION WORK, CONTRACTOR SHALL RESTORE
EXISTING UNDERGROUND UTILITY LINES HAVE BEEN DAMAGED AS A
DIVISION.
DURING EXCAVATIONS OF FUEL LINE TO THE COR AND ENVIRONMENTAL
THE CONTRACTOR SHALL REPORT ANY CONTAMINATED SOIL DISCOVERED
PROPER MATERIAL HANDLING METHODS.
MATERIALS WITHIN PROJECT LIMIT WITH COR CAREFULLY TO DETERMINE
CONTRACTOR SHOULD COORDINATE ANY SALVAGEABLE/RECYCLABLE
LEGEND:
ITEMS TO BE REMOVED
S
AC.
AC.
AC.
AC.
CURB.
CURB.
CURB.
SW.
IN
LET.
L/ P.
L/ S.
C/ G.
C/ G.
CL.
CL.
CL
S/ P.
.58
.15
.23
.14
.06
.93
.01
.29
.65
.76
.37
.18
.88
.59
.64
.18
.19
.24
.20
E
D
S
S
L/P
L/P
L/P
L/P
S/P
S
SCALE : 1 / 150
SITE LAYOUT PLAN
SEE DETAILS
INCLUDING BASE AND SUBBASE COURSE
REPLACE EXISTING ASPHALT CONCRETE PAVEMENT
SOD WITH TOP SOIL AND SOLID SODDING
SAME AS EXIST.
RESTORE EXISTING PAVEMENT MARKINGS
(BLDG. # S-810)
FAMILY HOUSING TOWER #2
PROJECT WORK LIMIT
EL.=91.054
ELEC. MANHOLE
TOP OF EXIST.
TBM
~A.C.~
~A.C.~
SCO : SURFACE CLEANOUT
L/P : LIGHTING POLE
S/P : SIGN AND POST
AC : ASPHALT CONCRETE
SCO
SCO
SCO
SCO
S
SCO
SCO
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
GRAPHIC SCALE
SCALE: 1 : 150
3000 6000
ABBREVIATIONS:
SAME AS EXIST.
RESTORE EXISTING CONCRETE CURB INLET
SAME AS EXIST.
RESTORE EXISTING CONCRETE CURB AND GUTTER
SEE DETAIL
INCLUDING BASE COURSE
REPLACE EXISTING CONCRETE SIDEWALK
LEGEND:
T.B.M. : TEMPORARY BENCH MARK
INCLUDING BASE AND SUBBASE COURSE
NEW ASPHALT CONCRETE PAVEMENT
INCLUDING BASE COURSE
NEW CONCRETE SIDEWALK
EXST. SEWER LINE
NEW SEWER LINES
EXST. STORM DRAIN LINEST
S
ST NEW STORM DRAIN LINE
SCOPE OF WORK
#1 (REPAIR/MAINTENANCE)
PARK, WON CHAE
CHI, K.K.
JA-00027-4J
AS SHOWN
CAMP WALKER
CIVIL
C-3
SITE LAYOUT PLAN
N
S
ID
E W
A L K
OUT INV. EL.=88.810 (TO EXISTING CONCRETE CURB INLET, ASSUMED)
IN INV. EL.=85.100 (FROM SUB-DRAINAGE LINE, ASSUMED)
IN INV. EL.=85.100 (FROM SUB-DRAINAGE LINE, ASSUMED)
TOP EL.=90.900 (ASSUMED)
LIFT STATION
TO EXST. SEWER LINE
NEW SEWER LINE SHALL BE CONNECTED
REROUTE UNDERGROUND UTILITY LINES
ACCORDANCE WITH DRAWING AND SPECIFICATIONS.>
1.
<ALL FAILED OR FAILING SYSTEM SHALL BE REPAIRED IN
NECESSARY ACCESSORIES, THRUST BLOCKS AND ANCHOR BLOCKS
PROVIDE DRAIN LINE, (PVC, VG1, D=100) INCLUDING FITTINGS,
SEE PROFILE AND DETAILS
AND ANCHOR BLOCKS WITH CONCRETE PROTECTION SLAB
FITTINGS, NECESSARY ACCESSORIES, THRUST BLOCKS
PROVIDE SEWER LINE, (PVC, VG1, D=100) INCLUDING
2.
WITH CONCRETE PROTECTION SLAB.
NECESSARY ACCESSORIES, THRUST BLOCKS AND ANCHOR BLOCKS
PROVIDE SEWER LINE, (PVC, VG1, D=100) INCLUDING FITTINGS,
1.
2.
#2 (GENERAL REQUIREMENTS)
SOD WITH TOP SOIL AND SOLID SODDING.
REROUTE UNDERGROUND UTILITY LINES.
8.
6.
4.
7.
3.
5.
PROVIDE LIFT STATION.
BASE AND SUBBASE COURSE.
REPLACE EXISTING ASPHALT CONCRETE PAVEMENT INCLUDING
COURSE.
REPLACE EXISTING CONCRETE SIDEWALK INCLUDING BASE
9.
RESTORE EXISTING CONCRETE CURB AND GUTTER.
RESTORE EXISTING CONCRETE DRAIN MANHOLE.
RESTORE EXISTING PAVEMENT MARKINGS.
RESTORE EXISTING CONCRETE CURB INLET.
REMOVE EXISTING SEWER LINES, CUT AND PLUG.10.
11.
12.
SEE REMOVAL NOTES ON DRAWING REF. NO. C-2.
SEE GENERAL NOTES ON DRAWING REF. NO. C-2.
NECESSARY ACCESSORIES, THRUST BLOCKS AND ANCHOR BLOCKS.
PROVIDE DRAIN LINE, (PVC, VG1, D=100) INCLUDING FITTINGS,
SAME AS EXST.
RESTORE EXISTING CONCRETE DRAIN MANHOLE
OUT INV. EL.=88.650 (TO EXST. SMH., ASSUMED)
IN INV. EL.=89.330 (EXST. ROOF DRAIN, ASSUMED)
IN INV. EL.=88.840 (FROM LIFT STATION, ASSUMED)
TOP EL.=90.360 (ASSUMED)
EXISTING CONCRETE SEWER MANHOLE
SEE PROFILE AND DETAILS
OUT INV. EL.=89.160 (TO EXISTING CONCRETE SEWER MANHOLE, ASSUMED)
IN INV. EL.=84.860 (FROM TOWER #2, ASSUMED)
TOP EL.=90.460 (ASSUMED)
PROVIDE LIFT STATION
AT AFH TOWER #2
SEPARATION OF STORM AND SEWER LINE
11 JUN 24
D - 24 - 28
3 8
2.
3.
1.
NOTES:
EARTH WORKED AREA SHALL BE PROPERLY COMPACTED IAW OMA SPECIFICATION.
4.
6 6
1 2
3 3
S
S
ST ST
(RCP, D=450)
(PVC, D=75)
ST
(R C
P
D
S T
S T
ST
(R
CP
, D
0)
ST
AND MATCH TO THE EXISTING GROUND ELEVATION.
FINISH SURFACE SHALL BE WELL GRADED AND HAVE POSITIVE DRAINAGE SURFACE
BE FULLY COVERED WITH SOLID SODDING AND TOP SOIL.
ALL UNPAVED, ISLAND, CUT/FILLED AREAS WITHIN THE PROJECT WORK LIMIT SHALL
TOP OF MANHOLE COVERS SHALL MATCH TO THE FINISH ELEVATION OF SIDEWALK.
S
S 3
SEWER LINE PROFILE
PARK, WON CHAE
CHI, K.K.
11 JUN 24
JA-00027-4J
AS SHOWN 4 8
D - 24 - 28
C-4
CAMP WALKER
CIVIL
THE STATIONS ARE APPROXIMATE AND ONLY FOR REFERENCE.
NOTES:
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
GRAPHIC SCALE
SCALE: 1 : 50
1000 2000
SHEET OF
LEGEND: 1
VER : 1 / 50, HOR : 1 / 50
SCALE
S T
A
.0
STA : STATION
CONCRETE PROTECTION SLAB
SEWER LINE PROFILE
E L E
V A T
IO
N
IN
M
T E
R S
S T
A
.3
(ASSUMED)
FINISH GROUND LEVELCONCRETE CURB & GUTTER CONCRETE CURB & GUTTER CONCRETE SIDEWALK
(ASSUMED)
EXST. STORM DRAIN LINE
2.
1.
EL : ELEVATION
(PVC, D=200)
EXST. SEWER LINE
UNDERGROUND UTILITY LINES SHOWN ON THE DRAWINGS OR NOT.
CONTRACTOR SHALL VERIFY THE EXISTING SITE CONDITION AND
(PVC, VG1, D=100)
SEWER LINE,
(T
X S T S
M H A
S S
U M
E D
O U
T
IN
V E L
.6
IN
IN
V E L
.3
(E
X S T R
O
F
D
A
IN
A S S
U M
E D
IN
IN
V E L
.8
(F
R
L
IF
T
S T
A T
IO
N
A S S
U M
E D
T O
P
E L
.3
(A
S S
U M
E D
E X S T S E
W
A
N H
O L E
CONCRETE PROTECTION SLAB
O U
T
IN
V E L
.1
(T
X S T S
M H A
S S
U M
E D
IN
IN
V E L
.8
(F
R
T
W E
R
A S S
U M
E D
T O
P
E L
.4
(A
S S
U M
E D
N
W
L
IF
T
S T
A T
IO
N
ABBREVIATION:
LIFT STATION DETAILS
PARK, WON CHAE
CHI, K.K.
11 JUN 24
JA-00027-4J
AS SHOWN 5 8
D - 24 - 28
C-5
CAMP WALKER
CIVIL
NOT TO SCALE53
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
REVIEWED BY
SHEET OF
FES
1 LIFT STATION DETAILS
A
PLAN
B
LIFT STATION
NEW CONCRETE
(D=100)
DISCHARGE PIPE
STAINLESS STEEL
fy = 440 Mpa fy = 392 Mpa (GRADE 60)
Fnt = 310 Mpa fu = 482 Mpa
1. CONCRETE : (MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS)
ALL CONCRETE UNLESS NOTED OTHERWISE
HOT-ROLLED DEFORMED BAR
2. STEEL
WELDED WIRE FABRIC
4. BOLTS :
ASTM A307,
3. WELDING ELECTRODE:
f’c = 24 MPa
MATERIAL STRENGTHS
1.
NOTES:
2.
3.PROVIDE FLEXIBLE JOINTS TO INSTALL PIPING FIRMLY.
STAINLEE STEEL PIPE SHALL BE CONNECTED TO PVC PIPE USING TRANSFER FITTING.
(TYP.)
(TYP.)
300 3001,700
2,300
LEAN CONCRETE, (T=50)
2.
1.
AND 40MM FOR OTHERS.
CONCRETE COVERS SHALL BE 75MM ON UNDERGROUND SURFACES
WHICHEVER THAT IS LONGER UNLESS OTHERWISE SPECIFIED.
REINFORCING BAR LAP LENGTH SHALL BE MIN. 300MM OR 30D
NOTES:
C
REINFORCING DETAILSB
SECTION
CAST IRON COVER AND OTHERS
SEE STANDARD DETAIL DRAWINGS FOR
ABBREVIATIONS:
O.C.
E.W.
E.F.
: EACH WAY
: EACH FACE
: ON CENTER
CAST IRON MANHOLE COVER IS NOT SHOWN FOR THE CLARITY.
SUBMERSIBLE PUMP SCHEDULE
ELECTRICAL DATAINPUT
POWER
DESCRIPTION
KW HP
208V
21.5
CAPACITY
20 GPM @ 50 FT, TDH
EQUIPMENT SCHEDULE
SEE SITE LAYOUT PLAN AND PROFILE FOR INVERT ELEVATIONS OF PIPE.1.
NOTES:
ANCHORED TO CONCRETE SURFACES.
IN THE PUMP PIT, PUMP, PIPING AND ACCESSORIES SHALL BE FIRMLY/PROPERLY
2.
3.
4.
5.
6.
DRAWING(S) OR NOT AND THESE ITEMS SHALL FUNCTION PROPERLY.
LIFTING CHAIN, GUIDE RAILS, BASE PLATE, BRACKETS AND ETC. SHOWN ON THE
INSIDE THE LIFT STATION, PUMP ACCESSORIES SHALL BE INSTALLED SUCH AS,
WITH STAINLESS STEEL DEBRIS STRAINER.
PUMP MATERIAL SHALL BE CORROSION AND OXIDATION RESISTANT MATERIAL
SEE ELECTRICAL DRAWING(S) FOR POWER SUPPLY AND CONTROL PANEL.
THE FUNCTION PROPERLY.
SHALL BE PROVIDED IAW THE MANUFACTURER’S SPECIFICATION TO DO
ALL REQUIRED PIPING AND FITTING ARE NOT SHOWN ON THE DRAWING
PIPING IN THE LIFT STATION SHALL BE ALL STAINLESS STEEL.
7.
STAINLESS STEEL PIPE SHALL BE SS316L MET TO KS AND ASTM A312, A269.
8.
9.
PUMP
SUBMERSIBLE
AUTOMATIC
SEE EQUIPMENT SCHEDULE FOR SUBMERSIBLE PUMP INFORMATION.
D13@200 O.C, E.W.,E.F.
M A
X .5 ,5
(CAGE IS NOT SHOWN)
STAINLESS STEEL LADDER AND CAGE
D=100
DISCHARGE PIPE,
SUBMERSIBLE PUMP
(TYP.)
2,300
(T Y P
1, FLOW
FLOW
PROTECTION SLAB AND CONCRETE SIDEWALK DETAILS
ASPHALT CONCRETE PAVEMENT, CONCRETE
PARK, WON CHAE
CHI, K.K.
11 JUN 24
JA-00027-4J
AS SHOWN 6 8
D - 24 - 28
C-6
CAMP WALKER
CIVIL
NOT TO SCALE
AC PAVEMENT TRANSITION DETAIL
63 NOT TO SCALE
NEW ASPHALT CONCRETE
PRIME COAT
100% LABORATORY MAX. DENSITY.
COMPACTED TO AT LEAST
(STABILIZED AGGREGATE)
AGGREGATE BASE COURSE (T=204)
100% LABORATORY MAX. DENSITY
COMPACTED TO AT LEAST
SUBBASE COURSE (T=204)
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
CONCRETE FINISH
AND WHERE WALKS ABUT OTHER CONCRETE STRUCTURES
STRAIGHT SECTIONS AND AT ALL RETURNS OF WALKS,
PROVIDE EXPANSION JOINTS AT MAXIMUM 15m INTERVALS FOR
3R
AGGREGATE USED.
BUT NOT LESS THAN THE MAXIMUM NOMINAL SIZE OF THE
BE AT LEAST ONE - FOURTH OF THE SIDEWALK SLAB THICKNESS.
EXCEED 1.25. THE DEPTH OF THE CONTRACTION JOINT WILL
THAT THE RATIO OF SLAB LENGTH TO WIDTH WILL NOT
TRANSVERSE CONTRACTION JOINTS SHALL BE SPACED SO
%(TYP)2
GRADE
FINISHED
MATERIAL BASE
COMPACTED NON-FROST-SUSCEPTIBLE
CONCRETE 21 MPA
SEE PLAN
WIDTH (VARIES)
NOT TO SCALE
CONCRETE SIDEWALK
EXST. AC SURFACE
EXST. SUBBASE COURSE
NEW AC PAVED
SECTION
COAT
BITUMINOUS TACK
SAW CUT & APPLY
NEW AC PAVEMENT
EXST. BASE COURSE
EXST. AC PAVEMENT
MIN.
PRIME COAT
JOINT FILLER JOINT SEALER
3R
9.5
NOT TO SCALE
PROTECTION SLAB (TYP.)
MATERIAL)
(SATISFACTORY
BACK FILL
ASPHALT SURFACE
SUBBASE COURSE
BASE COUSRE
EACH WAY
D13@250
CONCRETE PROTECTION SLAB
F R
O
T
D
P T
H
M
IN
(T Y P
SEWER LINE
1. APPLY BROOM FINISH PERPENDICULAR TO SIDEWALK PATH
fy = 440 Mpa fy = 392 Mpa (GRADE 60)
Fnt = 310 Mpa fu = 482 Mpa
1. CONCRETE : (MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS)
ALL CONCRETE UNLESS NOTED OTHERWISE
HOT-ROLLED DEFORMED BAR
2. STEEL
WELDED WIRE FABRIC
4. BOLTS :
ASTM A307,
3. WELDING ELECTRODE:
f’c = 24 MPa
MATERIAL STRENGTHS
EXPANSION JOINT
CONTRACTION JOINT
SECTION
ASPHALT CONCRETE PAVEMENT (T=102)
PANEL WIRING SHALL BE CONCEALED, BUT MAY BE EXPOSED WHERE NOT POSSIBLE.
ALL CONDUITS TO FIRE ALARM CONTROL PANEL SHALL BE RUN INTO THE SIDE OF THE
2.
3.
4.
5.
6.
3-#12AWG WIRES AND 1-#12AWG GROUND WIRE "THWN" IN 16mm CONDUIT.
4-#12AWG WIRES AND 1-#12AWG GROUND WIRE "THWN" IN 16mm CONDUIT.
7.
8.
9.
10.
11.
12.
13.
AN, CHAE YONG
E-1
N
WIRING CONCEALED IN CEILINGS AND WALL
C
WIRING CONCEALED IN FLOOR AND WALL
WIRING CONCEALED IN UNDERGROUND
HOMERUN CIRCUIT TO PANELBOARD OR ENCLOSURE
CONTROL CIRCUIT
WIRING EXPOSED ON CEILINGS, WALL AND SECONDARY OVERHEAD
LEGEND, NOTES AND SCOPE OF WORK
SAFETY SWITCH, FUSIBLE OR NON-FUSIBLE, VARIOUS CAPACITY
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
AS SHOWN
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISION DAEGU
DIRECTORATE OF PUBLIC WORK
UNIT #15746, APO AP 96218-5746
DATE:
SHEET OF
ELECTRICAL
MOUNTING HEIGHTS ARE AS BELOW. MEASUREMENT IS TO CENTER OF OUTLET.
2-#14AWG WIRES IN 16mm CONDUIT, (FOR BELL CIRCUIT, 24V DC LINE)
DISTANCE OF 460mm.
FIRE ALARM DETECTORS SHALL BE LOCATED TO CLEAR ANY LIGHTING FIXTURE A MINIMUM
ALL WIRING SHALL BE CONCEALD ABOVE CEILING WHEN THE ROOM HAS CEILING.
CONDUIT WHICH IS TO BE BONDED TO MAIN GROUNDING SYSTEM AT BOTH ENDS.
GROUNDING WIRE SHALL BE GREEN INSULATED COPPER WIRE IN RIGID GALVANIZED STEEL
WIRES IS INDICATED AS FOLLOW;
AND ONE (1)-#12AWG GROUND WIRE IN 16mm CONDUIT. A GREATER NUMBER OF
ANY CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES TWO (2)-#12AWG WIRES
FIRE ALARM CONTROL PANEL----------------------------1520mm ABOVE FLOOR
LIGHTING FIXTURE--------------------SEE LIGHTING FIXTURE SCHEDULE
TOGGLE SWITCH-----------------------1220mm TO CENTER OF THE OUTLET
RECEPTACLE---------------------------460mm TO CENTER OUTLET
PANELBOARD, CIRCUIT BREAKER------------------------SEE SPECIFICATION
COMMUNCATION LINE) IN 16mm CONDUIT.
1-#18AWG SHIELDED CABLE TWISTED PAIR (FOR SMOKE/HEAT DETECTOR SENSOR
2-#14AWG WIRES (FOR SMOKE DETECTOR POWER LINE, 24VDC) AND
PAIR IN 16mm CONDUIT, A GREATER NUMBER OF WIRES IS INDICATED AS FOLLOWS:
CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES ONE(1)-#18AWG SHIELD CABLE TWISTED
FIRE ALARM CIRCUIT SHALL BE DOUBLE LOOF SYSTEM IN A SEPARATE CONDUIT AND ANY
CAULKING MATERIAL SHALL BE VERIFIED BY F&ES OFFICE PRIOR TO CONSTRUCTION.
BOTH SIDE OF FIRE WALLS, FIRE-PARTITIONS, AND FIRE-RATED PIPE CHASE WALLS.
ALL PIPE PENETRATIONS SHALL BE SEALED WITH FIRE RATED CAULKING MATERIAL ON
SPECIFICATIONS FOR O&MA PROJECTS, AND SPECIFICATIONS.
ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE, FIRE CODE, TECHNICAL STANDARD
ALL ELECTRICAL WORK SHALL CONFIRM TO THE LATEST REQUIREMENTS OF THE NATIONAL
G E N E R A L N O T E S
MANUAL PULL STATION----------------------------------1370mm ABOVE FLOOR
FIRE ALARM BELL---------------------------------------2130mm ABOVE FLOOR
NON-PCB TRANSFORMER CERTIFICATION FOR EACH TO BE INSTALLED TRANSFORMER
INSTALLED TRANSFORMER. NEW TRANSFORMER WILL BE INSTALLED ATFER COR’S APPROVAL FOR
SUBMIT TWO COPIES OF NON-PCB TRANSFORMER CERTIFICATION TO COR FOR EACH TO BE
BEFOER CONTRACTOR REPLACE/INSTALL ANY TRANSFORMER AT USAG DAEGU, CONTRACTOR SHALL
L E G E N D
REMOVE NEW 1.
THE PROJECT.
AND SHALL BE APPROVED BY THE CONTRACTING OFFICER PRIOR TO COMMENCING WORK ON
THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ANY PORTION OF THE JOB BY THE COR
REVIEW BRANCH FOR APPROVAL PRIOR TO COMMENCING THE WORK.
THE CONTRACTOR SHALL PREPARE AND SUBMIT MATERIAL SUBMITTAL TO THE DESIGN AND TECHNICAL
THE CONTRACTOR SHALL INDICATE NAME TAG TO ALL ELECTRICAL ITEMS.
WORK CLASS: "K" (REPAIR / MAINTENANCE)
///// CC
SCOPE OF WORK
RECEPTACLE, SINGLE, 125V-20A, GRD’G TYPE.
MAGNETIC MOTOR STARTER, VARIOUS CAPACITY
AND THE COLOR OF TOGGLE SWITCHES AND RECEPTACLE SHALL BE IVORY.
ALL COVER PLATES OF RECEPTACLES AND SWITCHES SHALL BE STAINLESS STEEL METALLIC ONES
SIN, YONG SU
D - 24 - 28
7 8
JA-00027-4J
DUPLEX PUMP CONTROL PANEL W/ALTERNATOR
RECEPTACLE, SINGLE, 250V-20A, GRD’G TYPE,
GFCI RECEPTACLE, SINGLE, 250V-16A, GRD’G TYPE, LOCAL TYPE (KOREAN)
GFCI RECEPTACLE, DUPLEX, 125V-20A, GRD’G TYPE.
EXIST
CAMP WALKER
1. PROVIDE POWER AND PUMP CONTROL SYSTEM TO LIFT STATION WITH ALL NECESSARY ACCESSORIES.
< ALL FAILED OR FAILING SYSTEM SHOULD BE REPAIRED IN ACCORDANCE WITH DRAWINGS AND SPECIFICATION >
11 JUN 24
AC.
CURB.
.15
.21
.23
.39
E
D
S
L/P
L/P
SCO
SCO
SCO
S
S
ID
E W
A L K
S NEW LIFT STATION
PUMP CONTROL PANEL
EXISTING DUPLEX
PUMP CONTROL PANEL
NEW SIMPLEX
4-#14AWG IN 16mmC
1 SET FOR CONTROL
3-12#AWG & 1-12(G) IN 16mmC
1 SET FOR POWER
NEW GROUND ROD (TYPICAL)
(BLDG. # S-810)
FAMILY HOUSING TOWER #2
N
E-2
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
AS SHOWN
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISION DAEGU
DIRECTORATE OF PUBLIC WORK
UNIT #15746, APO AP 96218-5746
DATE:
SHEET OF
ELECTRICAL
GRAPHIC SCALE
AN, CHAE YONG
SIN, YONG SU
D - 24 - 28
- E-2
P-1
SCALE : 1 / 100
JA-00027-4J
SCALE: 1 : 100
2000 4000
SCALE : NOT TO SCALE- E-2
D-1 PUMP CONTROL INSTALLATION DETAIL
E
FLOW
CONTROL PANEL
NEW SIMPLEX PUMP
CONTROL PANEL
EXIST. DUPLEX PUMP
STOP PUMP
START PUMP
HIGH ALARM LEVEL
(CIVIL ITEM)
3P-208VAC-2HP-60Hz
SUBMERSIBLE PUMP
BASIC SEQUENCE OF OPERATION
1.
PUMP CONTROL PANEL SPECIFICATION
- POWER VOLTAGE: 3PH, 208VAC, 60HZ
- ENCLOSURE: NEMA 4X
2.
3.
4.
INFLOW
G
19mmD x 3000mmLG.
COPPER CLAD STEEL
GROUND ROD,
(M
IN
m m
1-#8 AWG "BC"
- HP RATING PER STARTER: 2.0HP
- CONTACTOR COIL VOLTAGE: 120VAC, 60HZ WITH STEP DOWN DRY-TRANSFORMER
- UL LISTED
- GREEN RUN PILOT LIGHT, FLASHING ALARM LIGHT, ALARM HORN W/SILENCE BUTTON, HAND-OFF-AUTO SWITCH
AS LIQUID IS PUMPED DOWN AND LEVEL GOES BELOW THE LOWER FLOAT SWITCH, THE PUMP WILL TURN OFF.
OFF - PUMP OFF
HAND - PUMP ON CONTINUOUSLY UNTIL SWITCH IS TURNED OFF.
- TYPE: THREE PHASE SIMPLEX PUMP CONTROL PANEL
CAMP WALKER
NEW PUMP CONTROL POWER PLAN
PUMP CONTROL INSTALLATION DETAIL
NEW PUMP CONTROL POWER PLAN AND
IN AUTO - AS LIQUID LEVEL RISES, THE UPPER FLOAT SWITCH CLOSES AND TURNS ON PUMP.
11 JUN 24
AT AFH TOWER #2
SEPARATION OF STORM AND SEWER LINE
8 8
CONDUIT SEALING FITTING
| JA-00027-4J_T01-Default-000 |
| JA-00027-4J_C01-Default-000 |
| JA-00027-4J_C02-Default-000 |
| JA-00027-4J_C03-Default-000 |
| JA-00027-4J_C04-Default-000 |
| JA-00027-4J_C05-Default-000 |
| JA-00027-4J_C06-Default-000 |
| JA-00027-4J_E01-Default-000 |
| JA-00027-4J_E02-Default-000 |