W90VN7-18-R-0059_Combined_Drawings.pdf

PDF 1 MB Posted

Attached to
CY18 LCS, Renovate Base Testing Rooms at Kunsan AB.
Solicitation number
W90VN7-18-R-0059
Issued by

About this file

W90VN7-18-R-0059_Combined Drawings

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N/A

N /A

N /A

N /A

E

W

PB

E

PB

N /A

N /A

PB

PB

N /A

N /A

06 14

18 24

PB

84 27

75 32

9B

9A

75 54

E

1025 10

E

W

5B

5A

8 11

2A

0A

PB

7A

4C

2A

0 20

3 42

9B

3B60

3A

3E

3D60

1 75

D -3

67 50

-S -A

-S

E

W

PB

PB

4B

4D

4A

7 22

7 20

9A

3C

72 50

40 26

32 28

73 32

W

W

1C

01 20

1A

1D

1B

R O

K A

F A

LE

R

TP

A

D

A lte rn at e H un g

O rd na nc e

G un

C le ar in g O ps

PR

IM

A

R Y

H un g O rd na nc e

G un C le ar in g

O ps

CL

EA

R

TW

Y

B

SO

U

TH

O

V

ER

FL

O

W

"C " P

A D

TR

A

N

SI

EN

TA

LE

R

T

N O

R

TH

LO

O

P

N O

R

TH

O V

ER

FL

O W

H O

T C

A R

G O

PA

D

V O

R

TA

C

TOUCHDOWN AREA

TOUCHDOWN AREA

TW

Y

E

SO

U

TH

LO

O P

TW

Y C

TWY P

TW

Y C

TW

Y

A

TR

A

N

SI

EN

TP

A D

TW

Y F

TWY G

TW

Y

D

TW

Y

A

TW

Y H

KAA TWY

OVERRUN

OVERRUN

E-

8' O

V R

N

LOCALIZERCRITICALAREA

E-

2' O

V R

N

B A

K

2'

'1

B A

K

2/

B A

K

FI

R

ED

EP

T

'9

B A

K

2/

B A

K

4'

A M

O

PS

X

C O

N

TR

O

LT

O W

ER

G

LI

D

ES

LO

PE

C R

IT

IC

A

LA

R

EA

A R

M /D

EA

R

M H

O

TB

R A

K

EH

Y D

R A

ZI

N

E A

R

EA

TR

EE

A R

EA

PRIMARY INSTRUMENT RUNWAY: 9000' x 150' RUNWAY GRADIENT = .124%

A R

M /D

EA

R

M H

O

TB

R A

K

EH

Y D

R A

ZI

N

E A

R

EA

X

A

SR

/P A

R

G

LI

D

ES

LO

PE

C R

IT

IC

A

LA

R

EA

5B

6B

7B

4A

54 49

3B

1B

4A

6A

8B10

5A

7A

1A

2A

4B

8A

2B

3A

8A

5A

R O

K A

FP

A

D

JU

VAT PAD

JU

VAT

FL

OW

S

WOLFPACK FLOW

PA

NTO

N F

LO

W S

TR

IM

P A

D

4400'

6600'

6800'

2400'

TW

Y

A

4600'

PB

45 10

8 11

7 22

5 21

1C

1A

1D

1B

PB

N/A N/A

72 50

NOT TO SCALE

SHT. NO. REF. NO. DESCRIPTION

DRAWING SCHEDULE

DRAWN BY:

DESIGNED BY:

CHECKED BY:

SCALE:

DRAWING NO:

PROJECT NO:

REF. NO:

CHIEF, CONSTRUCTION MANAGEMENT

CHIEF OF DESIGN

CHIEF OF CONTRACTS

ENVIRONMENTAL FLIGHT

FIRE DEPARTMENT

CORROSION ENGINEER

COMMUNICATIONS

BIOENVIRONMENTAL ENGINEERING

SAFETY

SECURITY POLICE

USING AGENCY

CHIEF, OPERATIONS FLIGHT

CHIEF, ENGINEERING FLIGHT

BASE CIVIL ENGINEER

AS SHOWN

KUNSAN AB, KOREA

LOCATION MAP & COVER SHEET

MLWR 12-1034

YUN

RENOVATE BASE TESTING ROOMS

MLWR 12-1034

SHEET 1 OF 6

C-1

HOSPITAL

ENGINEERING FLIGHT

CONSTRUCTION MANAGEMENT

YUN

KYH

UNITED STATES AIR FORCE

8th CIVIL ENGINEER SQUADRON

KUNSAN AIR BASE, REPUBLIC OF KOREA

B-1051

MAIN GATE

LOCATION MAPC-11 OF 6

BASE

BASE CIVIL ENGINEER

2 OF 6 A-1

3 OF 6 A-2 DOOR AND WINDOW DETAILS AND HARDWARE SCHEDULE

4 OF 6 A-3 DOOR AND WINDOW DETAILS

5 OF 6 A-4

NEW FLOOR AND CEILING PLAN FOR B-1051

CEILING DETAILS

NEW POWER PLAN FOR B-10516 OF 6 E-1

THIS PROJECT

MLWR 12-1034

RENOVATE BASE TESTING ROOMS

(B-1051)

SCALE

NEW POWER PLAN FOR TESTING RM IN BLDG1051

1/100mm

SCALE

EXST PNLBD "PB" DIAGRAM

: NOT TO SCALE

1_MLWR 12-1034C-1, Location Map & Cover Sheet-Layout1
2_MLWR 12-1034A-2, New Floor and Ceiling Plan for B1051-Layout1
3_MLWR 12-1034A-3, Door and Window Types and Hardware Set-2ND FLOOR PLAN
4_MLWR 12-1034A-4, Door and Window Details-2ND FLOOR PLAN
5_MLWR 12-1034A-5, Details of Ceiling-2ND FLOOR PLAN
6_MLWR 12-1034E-1, New Power Plan B1051-E-1