"Install Fall Protection system in Military Family Housing w indow s, OSAN AIR BASE"

THIS IS BUILDING GENERAL REPAIR IDIQ RFP FOR THE FOLLOWING CONTRACTORS ONLY:

CONTRACT NO.:W91QVN-19-D-0002, -0006, -0008, -0010, -0012.

OFFERORS MUST COMPLY WITH THE FOLLOWING:

A. Submission of Proposals

(1) Proposal Packet: It shall be submitted by 1300 hours on the closing date of RFP throuth FBO.

a. Bidding Schedule

b. Completion of Section K

C. If the contractor is unable to submit the proposal in response to this RFP, the contractor shall submit a "No-Offer Letter" by the date and time specif ied in this solicitation.

CPT BOOKWALTER, RANDY 315-757-6020

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS

NEGOTIATED

19-Jun-2019

(RFP)

(IFB)

X

CALL:

Install fall protection system for Military Fmaily Housing

B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)

See Item 7

2. TYPE OF SOLICITATION

SEALED BID

3. DATE ISSUED

9. FOR INFORMATION A. NAME

SOLICITATION

NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442 (REV. 4-85)

Prescribed by GSA

FAR (48 CFR) 53.236-1(e)

11. The Contractor shall begin performance w ithin _______10 calendar days and complete it w ithin ________270 calendar days after receiving aw ard, X notice to proceed. This performance period is mandatory, negotiable. (See _________________________

12 A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?

(If "YES," indicate within how many calendar days after award in Item 12B.)

YES X NO

13. ADDITIONAL SOLICITATION REQUIREMENTS:

A. Sealed offers in original and __________ copies to perform the w ork required are due at the place specified in Item 8 by ___________ local time ______________ (date). If this is a sealed bid solicitation, offers must be publicly opened at that time.

shall be marked to show the offeror's name and address, the solicitation number, and the date and time offers are due.

B. An offer guarantee is, X is not required.

C. All offers are subject to the (1) w ork requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.

D. Offers providing less than _______120 calendar days for Government acceptance after the date offers are due w ill not be considered and w ill be rejected.

SOLICITATION, OFFER,

AND AWARD

(Construction, Alteration, or Repair)

1. SOLICITATION NO.

IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.

4. CONTRACT NO.

7. ISSUED BY CODE

411TH CONTRACTING SUPPORT BRIGADE, KOREA

RCO OSAN, UNIT #2039

APO AP 96278-2039

UNITED STATES

W90VN6

PAGE OF PAGES

1 OF

CODE

(Title, identifying no., date):

12B. CALENDAR DAYS

(hour)

Sealed envelopes containing offers

5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.

SMYU20-4005

8. ADDRESS OFFER TO (If Other Than Item 7)

FAX:TEL: TEL: FAX:

W90VN619R0027 27

20B. SIGNATURE

(REV. 4-85)STANDARD FORM 1442 BACK

TO SIGN

NSN 7540-01-155-3212

SOLICITATION, OFFER, AND AWARD (Continued) (Construction, Alteration, or Repair)

CODE FACILITY CODE

17. The offeror agrees to perform the w ork required at the prices specif ied below in strict accordance w ith the terms of this solicitation, if this offer is accepted by the Government in w riting w ithin ________ calendar days after the date offers are due.

the minimum requirements stated in Item 13D. Failure to insert any number means the offeror accepts the minimum in Item 13D.)

AMOUNTS SEE SCHEDULE OF PRICES

18. The offeror agrees to furnish any required performance and payment bonds.

19. ACKNOWLEDGMENT OF AMENDMENTS

(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)

AMENDMENT NO.

DATE

20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN

OFFER (Type or print)

AWARD (To be completed by Government)

21. ITEMS ACCEPTED:

22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA

24. SUBMIT INVOICES TO ADDRESS SHOWN IN ITEM

(4 copies unless otherwise specified)

CODE

(Insert any number equal to or greater than

20C. OFFER DATE

25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO

10 U.S.C. 2304(c) 41 U.S.C. 253(c)

CODE27. PAYMENT WILL BE MADE BY:26. ADMINISTERED BY

(Include ZIP Code)14. NAME AND ADDRESS OF OFFEROR 15. TELEPHONE NO. (Include area code)

See Item 14

(Include only if different than Item 14)16. REMITTANCE ADDRESS

30B. SIGNATURE

29. AWARD (Contractor is not required to sign this document.)

document and return _______ copies to issuing office.) Contractor agrees Your of f er on this solicitation, is hereby accepted as to the items listed. This award con-to f urnish and deliv er all items or perf orm all work, requisitions identif ied summates the contract, which consists of (a) the Gov ernment solicitation and on this f orm and any continuation sheets f or the consideration stated in this y our of f er, and (b) this contract award. No f urther contractual document is contract. The rights and obligations of the parties to this contract shall be necessary .

gov erned by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, certif ications, and specif ications or incorporated by ref er-ence in or attached to this contract.

30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED 31A. NAME OF CONTRACTING OFFICER (Type or print)

30C. DATE

(Type or print)

TEL: EMAIL:

31B. UNITED STATES OF AMERICA 31C. AWARD DATE

BY

CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE

(Contractor is required to sign this28. NEGOTIATED AGREEMENT

(M ust be fully completed by offeror)OFFER

Section B - Supplies or Services and Prices

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0001 1 Job Install Fall protection system in B1015

FFP

SMYU20-4005 Install Fall Protection System in Military Family Housing windows. B1015 (Hallasan) QTY: 626 See SOW.

FOB: Destination

PSC CD: Z161

NET AMT

0002 1 Job Install Fall protection system in B1014

FFP

SMYU20-4005 Install Fall Protection System in Military Family Housing windows. B1014 (Jirisan) QTY: 590 See SOW.

0003 1 Job Install Fall protection system in B211

FFP

SMYU20-4005 Install Fall Protection System in Military Family Housing windows. B211 (Seoraksan) QTY: 472 See SOW.

0004 1 Job Install Fall protection system in B1065

FFP

SMYU20-4005 Install Fall Protection System in Military Family Housing windows. B1065 (SOQ) QTY: 6 See SOW.

0005 1 Job Install Fall protection system in B1017

FFP

SMYU20-4005 Install Fall Protection System in Military Family Housing windows. B1017 (SOQ) QTY: 20 See SOW.

0006 1 Job Install Fall protection system in B1078

FFP

SMYU20-4005 Install Fall Protection System in Military Family Housing windows. B1078 (SOQ) QTY: 20 See SOW.

0007 1 Job Install Fall protection system in B437

FFP

SMYU20-4005 Install Fall Protection System in Military Family Housing windows. B437 (SOQ) QTY: 8 See SOW.

Section C - Descriptions and Specifications

STATEMENT OF WORK

CONTRACT NUMBER:

W91QVN19D0002/6/8/10/12

PROJECT NUMBER: SMYU 20‐4005

DESCRIPTION: INSTALL WINDOW FALL PROTECTION

SYSTEM FOR MFH RA POC: 51 CES/CENMP (CHOE,

HANG SOK 784‐5706)

STATEME

NT OF

WORK

DATED:

03 JUN 19

1. GENERAL: The work to be performed for completion of this project shall be in general as described below and executed by the contractor.

1.1 Work by Contractor: The contractor shall provide all labor, tools, equipment, supplies and any other resources necessary to accomplish the scope of work contained herein as listed below and in accordance with the drawings, sketches and specifications.

1.2 Work by In‐House Forces: N/A

1.3 Work by Troop labor: N/A

2. TECHNICAL SPECIFICATIONS: Above project shall comply with specifications in awarded original contract package and attached ASTM F 2090.

3. SCOPE OF WORKS (SOW):

a. Architectural Works:

1. Install window opening control devices (WOCD) for gliding window and steel window guards (WG) for casement window on existing opening windows in Military Family Housing (MFH) to prevent children under the age of five from falling out of windows in accordance with UFC 4‐ 711‐01. The installed WOCD and WG shall limit the window’s net clear opening to 4” or less when the window sash is opened.

2. The quantities and location of the required WOCD and WG are as below table:

Building Number /Location

Q’ty

(EA)

Fall Protection Device/ Window Type

Remarks

B1015 (Hallasan) 626 (564+62)

WG/ Casement Window West Townes (Tower), common area (62EA) included

B1014 (Jirisan) 590 (570+20)

“ West Townes (Tower), common area (20EA) included

B211 (Seoraksan) 472 (433+39)

“ West Townes (Tower), common area (39EA) included

Sub‐Total (WG) 1,688

B1065 (SOQ) 6 WOCD/Gliding Window West Townes

B1017 (SOQ) 20 “ “

B1078 (SOQ) 20 “ “

B437 (SOQ) 8 “ East Townes

Sub‐Total (WOCD+ Extra

10EA)

Grand Total 1,752

3. The steel window guards (WG) for casement window shall comply with the requirements in ASTM F 2090 (*MFG/Model: Guardian Angel/Window Guards #3558‐45 or approved equal).

4. The WOCD for gliding window shall comply with the requirements in ASTM F 2090. Also extra ones and installation manual shall be provided to housing office for management (*MFG/Model: Anderson/WOCD for gliding windows or approved equal).

5. Before installation of the WOCD and WG, contact housing managers first to set up installation schedule for each dwelling unit.

6. Remove all of debris originated from the work and clean up the job site.

7. The contractor shall be responsible to repair all damages to existing areas caused by this project and to match condition to adjacent areas.

4. ATTACHED DRAWING/SINGLE LINE SKETCH OR PICTURES AND SPECIFICATION: Yes

5. CONTRACT PERFORMANCE PERIOD: 270 calendar days ARO and it includes off‐shore materials procurement + base pass authorization + military exercise (90 days) and construction period (180 days).

6. ATTACHED CLIN ITEMS INCL. COST (IGCE): Yes

7. REMARKS:

7‐1. Site Orientation will be strongly recommended. The contractor acknowledges that it has taken steps reasonably necessary to ascertain the nature and location of the works, and that it has investigated and satisfied itself as to the general and local conditions which can affect the work or its cost IAW FAR 52.236‐3.

7‐2. Time on target of the site release date will be discussed with the end user & BCE at the pre‐con meeting after award.

8. SECURITY REQUIRMENTS (AT/OPSEC):

The training IWATCH/EAGLE EYES/AT Level I shall be completed within 30 calendar days of contract award and within 30 calendar days of new employees commencing performance with the results reported to the COR NLT 45 calendar days after contract award.

ALERTS: During military alerts or special operations, the contractor may not be authorized on base or in the work site. When the contractor is prohibited from access to the base or work site for one (1) day or less per month, no adjustment in the contract time shall be made. When the contractor is prohibited access for more than one (1) day per month, adjustments shall be made in accordance with applicable clauses of the General Provisions.

BASE PASSES: The contractor shall be required to obtain base passes to Osan Air Base to perform the requirements of this contract. The contractor shall be responsible to submit a base pass request no later than five (5) calendar days after award of this contract. It should be noted that it can take up to 30 days or more to process base pass paperwork. It shall be the responsibility of the contractor to prepare the necessary base pass paperwork to include USFK Form 82‐E, USFK Form 225EK‐E, family history register, local register, etc. for each individual requiring access to Osan Air Base. The contractor shall also be authorized to receive vehicle passes for each of the contractor’s vehicles used in the performance of the requirements of this contract. It shall be the responsibility of the contractor to prepare the necessary paperwork to include USFK Form 195EK‐E, vehicle registration, vehicle insurance, certificate of safety inspection and a copy of driver’s license for each vehicle requiring access to Osan Air Base. The contractor shall prepare a cover letter listing each individual, skill, escort privileges, vehicle type, vehicle registration number, etc. The contractor shall also provide the COR with two (2) copies of this request letter, with carbons, to include the top copy with original signatures. Escort privileges will be justified and limited to specific needs for contract completion and at the discretion and approval of the sponsor and requesting authorities identified in Block 13 and Section III of the USFK Form 82‐E, Application for Installation/Base Access. The contractor shall not be authorized to perform any portion of the contract requirements until such time that the contractor has processed the necessary base pass paperwork for entry onto Osan Air Base. The COR shall not provide or be responsible to provide the contractor with escorts during performance of any part of this contract. All of the above documents shall be turned in to the COR for processing with the 51st Security Forces.

The contractor and all associated sub‐contractors shall practice Operations Security. The contractor shall not talk about work outside of the work area nor discuss the work being performed on social media. Unless absolutely necessary to perform the duties stated in the contract, the contractor shall not take pictures of or inside sensitive locations as determined by the contracting officer representative. It shall be the responsibility of the contractor to safeguard all documents provided.

Documents shall be stored away from view when not being used. Documents that are no longer needed shall be shredded in an approved government shredder.

Sung Yoon (DY Plus) pursuant to License Agreement. No further reproductions authorized.

Copyright by ASTM Int'l (all rights reserved); Tue May 7 06:11:43 EDT 2019 Downloaded/printed by

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.

Contact ASTM International (www.astm.org) for the latest information

Designation: F2090 − 10

StandardSpecification for Window Fall Prevention Devices With Emergency Escape (Egress) Release Mechanisms1

This standard is issued under the fixed designation F2090; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.

INTRODUCTION

This consumer safety specification addresses window fall prevention devices that protect against potential falls by children aged five years and under through open windows. Window fall prevention devices currently available include window opening control devices, window fall prevention screens, and some types of window guards. These devices use different strategies to prevent children from falling through open windows. Window opening control devices restrict the size of the open area of the window so that it is too small for a young child to fall through. They do this by allowing the window opening to be set at a predetermined position. Window fall prevention screens and fall prevention window guards provide a barrier to prevent a child from falling through an open window.

A special study2 by the U.S. Consumer Product Safety Commission (CPSC) indicates that young children are at risk of death and serious injury from falls through open windows. Children aged five and younger account for a higher percentage of window fall fatalities and injuries.3

Window fall prevention devices usually differ in purpose and application from security/burglar bars.

The general purpose of a window fall prevention device is to prevent a child age five or younger from falling through an open window. The general purpose of a security bar is to prevent unlawful entry through a window. Generally window fall prevention devices and security bars are two separate devices.

However, a security bar could be used as a fall prevention device if it meets the requirements of this specification.

The CPSC has advised caregivers to open windows less than 4 in. when children are present as one means to prevent child falls through open windows. Window opening control devices provide a means that the window, when opened in an initial operation, will satisfy the CPSC recommendation to open less than 4 in.4 The 4-in. dimension is drawn from related building codes and standards for openings in guardrail assemblies,5 and is universally accepted as the appropriate dimension to prevent a child from passing through balcony or guard railing systems. An additional operation is required to open the window further. The additional operation must be performed without the use of keys, tools, or special knowledge. Security from forced entry is not within the scope of this standard and is not the intended function of any of the devices referred to herein.

1 This specification is under the jurisdiction of ASTM Committee F15 on Consumer Products and is the direct responsibility of Subcommittee F15.38 on Window Fall Prevention.

Current edition approved March 15, 2010. Published April 2010. Originally approved in 2001. Last previous edition approved in 2008 as F2090 – 08. DOI:

10.1520/F2090-10.

2 U.S. Consumer Product Safety Commission, Special Window Falls Study, conducted in 1991.

3 U.S. Consumer Product Safety Commission, Special Window Falls Study, conducted in 1991 and “Window Safety: Data and Patterns Related to Entrapments and Accidental Falls from Windows,” prepared by Andersen Corporation.

Supporting data have been filed at ASTM International Headquarters and may be obtained by requesting Research Report RR:F15-1002.

4 Consumer Product Safety Commission, “Preventing Window Falls,” Document #5124.

1. Scope

1.1 This specification establishes requirements for devices

intended to address the risk of injury and death associated with accidental falls through open windows by children five years old and younger.

1.2 This specification is not intended to meet the unique

requirements of Americans With Disabilities Act (ADA).

1.3 This specification applies to window fall prevention

devices, including window opening control devices, window

5 See NFPA 101, 2006 Edition, Section 7.2.2.4.5.3. Also see Section R312.2, guard opening limitations in the 2006 International Residential Code (IRC).

Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States

Downloaded/printed by

F2090 − 10 fall prevention screens, and fall prevention window guards, that are to be used on any windows, including those that are designated for emergency escape (egress) and rescue (ingress).

NOTE 1—A separate safety specification, Safety Specification F2006, covers window fall prevention devices for non-emergency escape (egress) and rescue (ingress) windows in installations more than 75 ft6 (23 m) above ground level in multiple family dwelling buildings since windows at these heights are beyond the reach of rescue ladders currently in use.

1.4 The values stated in inch-pound units are to be regarded

as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.5 This standard does not purport to address all safety

concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regula-tory limitations prior to use.

2. Referenced Documents

2.1 ASTM Standards:7

F977 Consumer Safety Specification for Infant Walkers F1487 Consumer Safety Performance Specification for Play-ground Equipment for Public Use F2006 Safety Specification for Window Fall Prevention

Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows

2.2 Code of Federal Regualtions:8

16 CFR 1500.53 Test Methods for Simulating Use and Abuse of Toys and Other Articles Intended for Use by Children Over 36 But Not Over 96 Months of Age, (f)(3) Testing Procedure

16 CFR 1508.6(b) Requirements for Full-Size Baby Cribs CPSC 16 CFR Chapter 11 (1-1-87 Edition) Part 1201 Safety

Standard for Architectural Glazing Materials

2.3 ANSI Standards:9

ANSI Z535.4 Product Safety Signs and Labels ANSI Z535.6 Product Safety Instructions in Product

Manuals, Instructions and Other Collateral Materials ANSI Z97.1-1984 Safety Glazing Materials Used in Build-ings — Safety Performance Specifications and Methods of Test (Tempered Glass Impact Test)

ANSI/BHMA A156.9 American National Standard for Cabi-net Hardware

ANSI/SMA 1201-2002 Specification for Insect Screens for Windows, Sliding Doors and Swinging Doors

6 2006 International Building Code, Section 403.1, Special Provisions for Groups B and R1, January 2000.

7 For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards volume information, refer to the standard’s Document Summary page on the ASTM website.

8 Code of Federal Regulations, available from U.S. Government Printing Office, Washington, DC 20402.

9 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.

2.4 AAMA Standards:10

AAMA/WDMA/CSA 101/IS.2/A440-08 North American Fenestration Standard/Specification for Windows, Doors, and Skylights

AAMA 902 Voluntary Specification for Sash Balances

3. Terminology

3.1 Definitions of Terms Specific to This Standard:

3.1.1 aftermarket, adj—referring to a product or device that is manufactured separately from a window but is intended to be used in conjunction with a window. For purposes of this standard, such a device is intended to be attached to or near a window or its frame in order to prevent a young child from passing or falling through the window when the window is opened.

3.1.2 emergency escape (egress) and rescue (ingress) window, n—a window intended for emergency escape (egress) and rescue (ingress) during an emergency situation such as fire, gas leak, etc., as defined by the prevailing applicable building and fire codes.

3.1.3 fall prevention window guard, n—device designed to fit into or onto a window to prevent a child from passing or falling through an open window. Typically mounted on the interior frame of the window and includes side frames fastened to the sides of a window frame and a plurality of spaced-apart, transverse, tubular, width-adjustable crosspiece elements to form a grid pattern between the side supports to prevent passage of a child.

3.1.4 release mechanism for emergency escape (egress) and rescue (ingress) window fall prevention device, n—means of opening a window fall prevention screen or fall prevention window guard or releasing a window opening control device to provide a clear opening space for the purpose of emergency escape or rescue.

3.1.5 window, n—an opening constructed in a wall or a roof to admit light or air, or both, to any enclosure.

3.1.6 window fall, n—a fall through an open window.

3.1.7 window fall prevention device, n—any device intended to prevent a young child from passing or falling through an open window. Such a device may be an integral part of a window, or may be attached to the window, its frame, or the area around the window after the window has been installed.

3.1.8 window fall prevention screen, n—screen device de-signed to fit into or onto a window to prevent a child from passing or falling through an open window. Typically mounted on the exterior surface/frame of a sliding style window and on the interior of a cranking style window and includes screening mesh or material and attachment mechanism(s) of sufficient strength to meet the performance requirements of this standard while preventing passage of a child.

3.1.9 window opening control device, n—device that limits a window sash to be opened with normal operation of the sash

10 Available from American Architectural Manufacturers Association, 1827

Walden Office Square, Suite 550, Schaumburg, IL 60173, http://www.aamanet.org/ index.asp.

Downloaded/printed by such as to prohibit the free passage of a 4.0-in. (102-mm) diameter rigid sphere11 at the lowest opening portion of the window opening, with a release mechanism that shall allow the sash to be opened to a larger opening area such as that required for emergency escape and rescue, and that automatically resets when the window sash is fully closed.

3.1.9.1 controlled open position, n—maximum open posi-tion of a window sash, when the window opening control device(s) is engaged, that prohibits the free passage of a 4-in.

(102-mm) diameter rigid sphere.

4. General Requirements

WINDOW FALL PREVENTION SCREENS AND FALL

PREVENTION WINDOW GUARD DEVICES

4.1 Window fall prevention screens or fall prevention win-

dow guard devices shall be constructed so as to prohibit the free passage of a 4.0-in. (102-mm) diameter rigid sphere12 anywhere in the window opening (as required by applicable codes for that jurisdiction), during or after testing as specified in 8.1 through 8.4, when the window fall prevention screen or fall prevention window guard device is installed in accordance with the manufacturer’s instructions.

4.2 The distance between window fall prevention screen or

fall prevention window guard device structural members or components after all testing is conducted shall not exceed 4.0 in.

(102 mm) when a 60-lbf13 (267-N) direct force is applied in accordance with the test method in 8.2.

4.3 Releasable window fall prevention screen or fall pre-

vention window guard devices shall be free of sharp projec-tions and edges.

4.4 Releasable window fall prevention screens or fall pre-

vention window guard devices shall not interfere with the operation, function or performance of the window to applicable standards and shall not violate light, ventilation, and emer- gency escape and rescue requirements of the applicable build- ing code.

4.5 Window fall prevention screens or fall prevention win-

dow guard devices shall be designed with release mechanisms to allow for emergency escape (egress) without the need for special tools or special knowledge.

4.5.1 Operation of emergency escape (egress) mechanisms

shall be accomplished with a minimum amount of effort from the inside of the building, whether the window fall prevention screen and fall prevention window guard device is mounted inside or outside the building.

11 CPSC Publication 362, “Safety Barrier Guidelines for Home Pools” and New Jersey Community Affairs Division of Codes and Standards, Cite 27 N.M.R. 3150, Subchapter 27 Child-Protection Window Guards — 5:10 — 27.4 — Specifications for Window Guards.

12 CPSC Publication 362, “Safety Barrier Guidelines for Home Pools” and New Jersey Community Affairs Division of Codes and Standards, Cite 27 N.M.R. 3150, Subchapter 27 Child-Protection Window Guards — 5:10 — 27.4 — Specifications for Window Guards.

13 “Anthropometry of Infants, Children, and Youths to Age 18 for Product Safety Design,” Highway Safety Research Institute, University of Michigan, May 31, 1977.

4.5.2 Release of the emergency escape (egress) mechanism

shall require no more than 15 lbf (66 N) of force.14

4.5.3 To protect against inadvertent operation by a young

child, the emergency escape (egress) release mechanism(s) shall require two distinct actions to operate.15 Opening the window fall prevention screen or fall prevention window guard shall not count as one of these actions.

4.5.4 The emergency escape (egress) release mechanism

shall operate properly in all types of weather.

4.5.5 Emergency escape (egress) releases shall have their

operating mechanisms clearly identified for proper use in an emergency.

4.5.6 Neither the window fall prevention screens or fall

prevention window guard devices nor the emergency escape (egress) release mechanism shall reduce the exitable area of the window unit below what is required by applicable codes.

4.5.7 The location of the release mechanism to be used to

open the window fall prevention screens or fall prevention window guard devices shall be visible.

4.6 Window fall prevention screens or fall prevention win-

dow guard devices, if hinged, shall be hinged on one side (not top or bottom) to provide easy escape (egress) and if interior mounted shall not operate outward.

4.7 Once released, window fall prevention screen or fall

prevention window guard devices shall not re-engage until manually closed.

4.8 Releasable window fall prevention screen or fall pre-

vention window guard devices shall be designed in a manner that does not accommodate the use of locking devices which require special knowledge or tools to operate, such as combi- nation locks or keyed locks, whereby the device could be locked in a closed position to some part of the building structure or to some non-moveable portion of the device itself and thereby be rendered not readily operable in the event of an emergency.

4.9 Each releasable window fall prevention screen or fall

prevention window guard device shall be sold with installation instructions and safety information included in the packaging for each device.

4.10 Installation instructions shall include the statement that a copy of the safety information shall be provided to the owner of the building in which the device is installed and to the occupant in the dwelling where the device is installed (or is to be installed).

4.11 Installation instructions and safety information shall be conspicuous.

4.12 Installation instructions and safety information shall

specify maximum window opening width and height for which the window fall prevention device is intended.

4.13 Additional requirements for window fall prevention

screen assemblies used as window fall prevention devices.

14 16 CFR 1500.53, Test Methods for Simulating Use and Abuse of Toys and Other

Articles Intended for Use by Children Over 36 But Not Over 96 Months of Age, (f)(3) Testing Procedure.

15 16 CFR 1508.6(b), Requirements for Full-Size Baby Cribs.

Downloaded/printed by

4.13.1 Window fall prevention screen assemblies designed

for exterior installation shall meet the weathering and durabil-ity requirements of ANSI/SMA 1201-2002: “Specification for Insect Screens for Windows, Sliding Doors and Swinging Doors.”

4.13.2 Attachment of window fall prevention screen assem-

blies to window units, framing, or surrounding materials shall not interfere with the operation, function, or performance of the window to applicable standards, and shall not violate light, ventilation, and emergency escape and rescue requirements of the applicable building code.

4.13.3 Window fall prevention screen assemblies used as

window fall prevention devices shall comply with applicable standards contained in ANSI/SMA 1201-2002: “Specification for Insect Screens for Windows, Sliding Doors and Swinging Doors.”

4.13.4 Where window fall prevention screens are

considered, the person specifying the window fall prevention screen(s) shall refer to this specification or Safety Specification F2006.

NOTE 2—Insect screens are intended to provide reasonable insect control and are not intended nor designed for the purpose of providing security or to provide for the retention of objects or persons.

WINDOW OPENING CONTROL DEVICES

4.14 Window opening control devices shall be tested in

accordance with 8.5 through 8.9.

4.15 Window opening control devices, when properly in-

stalled and engaged, shall prohibit the free passage of a 4.0-in.

(102-mm) diameter rigid sphere16 through the window opening before and immediately after testing in accordance with 8.5 through 8.8.

4.16 The window opening control device shall meet the force

criteria in 8.5 through 8.9.

4.17 Window opening control devices shall be designed with

release mechanisms to allow for emergency escape (egress) without the need for keys, tools or special knowledge. Window latching hardware meeting the requirements of this standard shall be permitted to serve as the release mechanism.

4.17.1 Window opening control devices shall be designed

and installed so that they will function properly during normal operation of the window to limit the opening area, while maintaining structural integrity and durability.

4.17.2 Release of the emergency escape (egress) mechanism

of the window opening control device shall require no more than 15 lbf (66 N) of force.17

4.17.3 To protect against inadvertent opening of the window

sash beyond the controlled open position by a young child, the emergency escape (egress) release mechanism(s) of the win-dow opening control device(s) shall consist of either two

16 CPSC Publication 362, “Safety Barrier Guidelines for Home Pools” and New Jersey Community Affairs Division of Codes and Standards, Cite 27 N.M.R. 3150, Subchapter 27 Child-Protection Window Guards — 5:10 — 27.4 — Specifications for Window Guards.

17 16 CFR 1500.53, Test Methods for Simulating Use and Abuse of Toys and Other Articles Intended for Use by Children Over 36 But Not Over 96 Months of Age, (f)(3) Testing Procedure.

independent single action mechanisms or one dual action mechanism. Operation of the sash shall be able to be performed independently of operation of the release mechanism.

4.17.3.1 Single Action Mechanisms—Operation of the two

independent single action emergency escape (egress) release mechanisms shall be able to be performed consecutively.

4.17.3.2 Dual Action Mechanism—The dual action emer-

gency escape (egress) release mechanism shall require two separate, distinct, and consecutive actions to release the mecha-nism. Maintaining the first action while performing the second action, such as pushing and then turning, shall be permitted for a dual action device, as long as the two actions are separate, distinct and consecutive.

4.17.4 The emergency escape (egress) release mechanism

shall operate properly within all reasonably foreseeable oper-ating conditions, including weather.

4.17.5 Emergency escape (egress) releases shall have their

operating mechanisms clearly identified for proper use in an emergency.

4.17.6 The window opening control device and emergency

escape (egress) release mechanism shall not reduce the open area of the window unit beyond applicable code requirements for minimum opening size.

4.17.7 The emergency escape (egress) release mechanism

shall be readily visible.

4.18 Once released, when the window sash is returned to a

fully closed position, the window opening control device(s) release mechanism(s) shall automatically reset. Resetting shall occur at any position between the controlled open position and the fully closed position.

4.19 Window opening control devices shall not interfere with

the operation, function or performance of the window to applicable standards and shall not violate light, ventilation, and emergency escape and rescue requirements of the applicable building code.

4.20 Each aftermarket window opening control device shall

be sold with installation and operating instructions and safety information included in the packaging. Instructions for factory installed opening control devices shall be included with the window manufacturer instructions.

4.21 Installation instructions shall include the statement that a copy of the safety information shall be provided to the owner of the building in which the opening control device is installed and to the occupant in the dwelling where the opening control device is installed (or is to be installed).

4.22 Installation instructions and safety information shall

specify any applicable design limitations, including maximum window width and height for which the window opening control device is intended.

5. Installation Instructions

WINDOW FALL PREVENTION SCREENS, FALL

PREVENTION WINDOW GUARDS, AND FACTORY

APPLIED/INSTALLED WINDOW OPENING

CONTROL DEVICES

5.1 Installation instructions for window fall prevention

screens and fall prevention window guards shall specify that

Downloaded/printed by window fall prevention devices shall be installed in such a manner that no space shall exist anywhere in the window opening (as required by applicable codes for that jurisdiction) with the window fall prevention device installed that would permit the passage of a rigid sphere measuring 4.0 in. (102 mm) in diameter. Installation instructions shall state that failure to follow these instructions may result in the window fall prevention device’s being ineffective in preventing falls through an open window.

5.1.1 Installation instructions for opening control devices

shall specify that when the window opening control device is properly installed and engaged, that no space shall exist at the lowest opening portion of the window opening, that would permit the passage of a rigid sphere measuring 4.0 in. (102 mm) in diameter. Installation instructions shall state that failure to follow these instructions may result in the window opening control device’s being ineffective in preventing falls through an open window.

5.2 Installation instructions shall specify application to spe-cific window type. The installation instructions shall include all details of recommended attachment materials and techniques of installation that will provide for support equal to or greater than the attachment methods and materials used to meet the test requirements as described in 8.1 through 8.9. Installation instructions shall include the statements specified in 5.2.2 and 5.2.3.

5.2.1 Installation Instructions shall specify that building and fire codes should be consulted before installing window fall prevention devices. Contact local building code department or fire department for specific codes.

5.2.1.1 Window fall prevention device shall be installed such that the release mechanism(s) is in conformance with local building and fire code requirements.

5.2.2 Where a warning18 is required by this specification

within the installation instructions, a signal word panel (see below) that contains the word “WARNING” in upper case letters, preceded by a safety alert symbol consisting of an exclamation mark inside a solid equilateral triangle back- ground with the point of the triangle oriented upward shall head the information. The word “WARNING” and the safety alert symbol shall be centered on one line and shall be in letters at least 5∕16

in. (7.9 mm) high.

"WARNING

5.2.3 Within the installation instructions a warning message

shall include the statement of the hazard: “Possible Fall Hazard” and shall contain the following information:

Possible Fall Hazard

• Young children may fall out of the window if the window fall prevention device is not installed correctly.

–Install the device so that a rigid 4.0-in.–diameter sphere does not pass through any space in the window opening after the window fall prevention device is in place.

• Young children may fall out the window if all installation instructions are not followed:

–Use recommended materials and techniques.

–Make sure the fall prevention device is securely attached to the window frame.

–Make sure that the window frame is in good condition.

5.2.4 Installation instructions shall include directions to

check release mechanism for operability when installation is completed and then close securely.

5.2.5 Installation instructions shall describe how to re–en-

gage the window fall prevention device after activation of release mechanism to check for operability.

WINDOW OPENING CONTROL DEVICES

DESIGNED FOR AFTERMARKET APPLICATIONS

5.3 Installation instructions shall specify that when the

window opening control device is properly installed and engaged, that no space shall exist at the lowest opening portion of the window opening, that would permit the passage of a rigid sphere measuring 4.0 in. (102 mm) in diameter. Installa- tion instructions shall state that failure to follow these instruc- tions may result in the window opening control device’s being ineffective in preventing falls through an open window.

5.4 Installation instructions shall specify application to spe-cific window type. The installation instructions shall include all details of recommended attachment materials and techniques of installation that will provide for support equal to or greater than the attachment methods and materials used to meet the test requirements as described in 8.5 through 8.9. Installation instructions shall include the statements specified in 5.4.2 and 5.4.3.

5.4.1 Installation Instructions shall specify that building and fire codes shall be consulted before installing window opening control devices. Contact local building code department or fire department for specific applicable codes.

5.4.1.1 Window opening control devices shall be installed

such that the release mechanism(s) is in conformance with local building and fire code requirements.

5.4.2 Where a warning19 is provided within the installation

instructions, a signal word panel (see below) that contains the word “WARNING” in upper case letters, preceded by a safety alert symbol consisting of an exclamation mark inside a solid equilateral triangle background with the point of the triangle oriented upward shall head the information. The word “WARNING” and the safety alert symbol shall be centered on one line and shall be in letters at least 5∕16 in. (7.9 mm) high.

18 WARNING format to be written in accordance with ANSI Z535.4, “Product Safety Signs and Labels,” and ANSI Z535.6, “Product Safety Instructions in Product Manuals, Instructions and Other Collateral Materials,” requirements unless other-wise approved by applicable building codes or fire codes, or both.

19 WARNING format to be written in accordance with ANSI Z535.4, “Product Safety Signs and Labels,” and ANSI Z535.6, “Product Safety Instructions in Product Manuals, Instructions and Other Collateral Materials,” requirements unless other-wise approved by applicable building codes or fire codes, or both.

Downloaded/printed by

5.4.3 Within the installation instructions a warning message

shall include the statement of the hazard: “Possible Fall Hazard” and shall contain the following information:

• Young children may fall out of the window if the opening control device is not installed correctly.

–Install the device so that a rigid 4.0-in.–diameter sphere does not pass through any space in the window opening after the window fall prevention device is in place.

• Young children may fall out the window if all installation instructions are not followed:

–Use recommended materials and techniques.

–Make sure that the window opening control device is securely attached, as directed, to the window frame.

–Make sure that the window frame is in good condition.

5.4.4 Installation instructions shall include directions to

check release mechanism for operability when installation is completed and then close securely.

5.4.5 Installation instructions shall describe how to re-

engage the window opening control device after activation of release mechanism to check for operability.

6. Safety Information

6.1 Safety information shall be distinct from the Installation Instructions. Safety information shall be headed “IMPOR- TANT SAFETY INFORMATION” and shall contain a note of attention to the installer to leave the safety information behind for the occupant.

6.2 Safety information shall include at least the information, signal word panels, and graphics contained in 6.4, 6.5, and 6.6.

(Sample safety information is included in the Appendix.)

6.3 Safety information shall specify that window fall pre-

vention devices, including window fall prevention screens, or fall prevention window guards (Note to manufacturers: Use whatever term applies to your device) shall be installed in such a manner that, after the device is installed and engaged, no space shall exist anywhere in the window opening (as required by applicable codes for that jurisdiction) that would permit the passage of a rigid sphere measuring 4.0 in. (102 mm) in diameter.

6.3.1 Safety information shall specify that window opening

control devices shall be installed in such a manner that, after the device is installed and engaged, no space shall exist at the lowest opening portion of the window opening that would permit the passage of a rigid sphere measuring 4.0 in. (102 mm) in diameter.

6.3.2 The safety information in 6.4, 6.5 and 6.6 shall be

headed by a signal word panel (see below) and shall contain the word “WARNING” in upper case letters, preceded by a safety alert symbol consisting of an exclamation mark inside a solid equilateral triangle background with the point of the triangle oriented upward. The word “WARNING” and the safety alert symbol shall be centered on one line and shall be in letters at least 5∕16 in (7.9 mm) high.

6.4 The safety information shall include the statement of the hazard, “No Window Rescue Above 75 ft (6th Floor),” and shall contain the following information:

No Window Rescue Above 75 ft (6th Floor)

• Fire rescue ladder may not reach beyond 75 ft (6th floor).

• Do not rely on being rescued from windows above 75 ft (6th floor). Follow building fire escape plan.

6.5 The safety information shall include the statement of the hazard, “Blocks Escape in Fire and Emergency Unless Released,” and shall contain the following information:

Blocks Escape in Fire and Emergency Unless Released

• Need to properly operate release mechanism to open window fall prevention device, including window opening control device, window fall prevention screen, or fall prevention window guard (Note to manufacturer: Use whatever term applies to your device) by:

-Note to manufacturer: Give instruction on how to correctly operate the release mechanism on your particular window fall prevention device.

• Never apply padlocks or devices that require a key or tool to unlock them to the release mechanism and/or window fall prevention device, including window opening control devices, window fall prevention screens, or fall prevention window guards (Note to manufacturer: Use whatever term applies to your device).

6.6 The safety information shall include the statement of the hazard; “Possible Fall Hazard” and shall contain the following information:

• If window fall prevention device, including window opening control devices, window fall prevention screens, or fall pre-vention window guards (Note to manufacturer: Use whatever term applies to your device) is too small for the window opening, accidental window falls can result.

• Follow manufacturer’s assembly and installation instructions carefully. Failure to do so may result in accidental window falls.

• This window fall prevention device, including window

Downloaded/printed by opening control devices, window fall prevention screens, or fall prevention window guards (Note to manufacturer: Use whatever term applies to your device) is designed to protect against accidental window falls by children five years and younger.

• This window fall prevention device, including window opening control devices, window fall prevention screens, or fall prevention window guards (Note to manufacturer: Use whatever term applies to your device) is not a substitute for careful supervision of all young children.

• Keep window fall prevention device, including window opening control devices, window fall prevention screens, or fall prevention window guards (Note to manufacturer: Use whatever term applies to your device) closed securely unless needed for use in an emergency.

6.7 Safety information shall describe how to re-engage the

window fall prevention device, including window opening control devices, window fall prevention screens, or fall pre-vention window guards (Note to manufacturer: Use whatever term applies to your device) after activation of device to check for operability.

6.8 Safety information shall include directions on how to

operate the release mechanism and provide an explanation for the need to activate the release mechanism.

6.9 Safety information shall include recommendations that

release mechanism and releasable window fall prevention device, including window opening control devices, window fall prevention screens, or fall prevention window guards (Note to manufacturer: Use whatever term applies to your device) be maintained and tested on a monthly basis (once a month) and after testing be closed securely.

6.10 Safety information shall include recommendations that

all household members six years old and older should know how to operate the release mechanism in case of an emergency.

7. Labeling Requirements

7.1 The aftermarket window fall prevention device, includ-

ing window opening control devices, window fall prevention screens, or fall prevention window guards shall be marked or identified in a manner as to provide traceability to the manu-facturer.

7.2 The packaging for the window fall prevention device, including window opening control devices, window fall pre-vention screens, or fall prevention window guards shall iden- tify the name of the manufacturer, retailer or distributor, any appropriate applications and restrictions such as maximum window opening width and height and the statement “this device complies with ASTM F2090-10” on or in the packag- ing.

7.3 Explain the function of the aftermarket window fall

prevention device, including window opening control devices, window fall prevention screens, or fall prevention window device, the following information:

Child Fall Prevention Window Device (Note to manufacturer: Use whatever term applies to your device) In Emergency

Do XXXXX to Escape

7.3.1 “Do XXXXX” is a brief description of how to operate the release mechanism of the window fall prevention device (Note to manufacturer: Use whatever term applies to your device) which you are supplying. This tag label may be in pictorial form. The label shall be permanently printed or embossed on a permanent hang tag or on some other type of permanent label such as a sleeve.

8. Performance Tests

WINDOW FALL PREVENTION SCREENS AND FALL

PREVENTION WINDOW GUARD DEVICES

8.1 Preparing Specimen for Testing:

8.1.1 Window fall prevention guards shall be extended to the

maximum width and height as specified by the manufac- turer.

Extended fall prevention window guards and window fall prevention screens shall be mounted in a test frame or holder materials using installation techniques…