PART SIZE PART DESCRIPTION QUANTITY
UNIT OF
ISSUE DELIVERY* UNIT PRICE TOTAL PRICE
Lumber 2" x 8" x 14'
Lumber, #2 or better graded, KD HT lumber
Material MUST FOLLOW;
ASTM D6199-07(2012), SPECIFICALLY: SECTION 6, 5.1 CLASS 1--STRUCTURAL (HIGHLY
STRESSED MEMBERS), 6,1.1.1-- GROUP I WOOD , 6.5.5-- NO WANE IS PERMITTED,
LOADS OF LUMBER MUST BE INDIVIDUALLY WRAPPED WITH A TARP STYLE
MATERIAL, 14 FOOT LENGTHS ONLY
***NO EXCEPTIONS*** 350 EACH 7-DAYS $0.00
Plywood A/C, 3/4" x 48" x 96" Plywood, A/C, 3/4" x 48" x 96" 4,200 EACH 7-DAYS $0.00
Lumber 2" x 10" x 14'
Lumber, #2 or better graded, KD HT lumber
Material MUST FOLLOW;
ASTM D6199-07(2012), SPECIFICALLY: SECTION 6, 5.1 CLASS 1--STRUCTURAL (HIGHLY
STRESSED MEMBERS), 6,1.1.1-- GROUP I WOOD , 6.5.5-- NO WANE IS PERMITTED,
LOADS OF LUMBER MUST BE INDIVIDUALLY WRAPPED WITH A TARP STYLE
MATERIAL, 14 FOOT LENGTHS ONLY
***NO EXCEPTIONS*** 450 EACH 7-DAYS $0.00
Lumber 4" x 10" x 14'
Lumber, #2 or better graded, KD HT lumber
Material MUST FOLLOW;
ASTM D6199-07(2012), SPECIFICALLY: SECTION 6, 5.1 CLASS 1--STRUCTURAL (HIGHLY
STRESSED MEMBERS), 6,1.1.1-- GROUP I WOOD , 6.5.5-- NO WANE IS PERMITTED,
LOADS OF LUMBER MUST BE INDIVIDUALLY WRAPPED WITH A TARP STYLE
MATERIAL, 14 FOOT LENGTHS ONLY
***NO EXCEPTIONS*** 105 EACH 7-DAYS $0.00
Lumber 2" x 6" x 14'
Lumber, #2 or better graded, KD HT lumber
Material MUST FOLLOW;
ASTM D6199-07(2012), SPECIFICALLY: SECTION 6, 5.1 CLASS 1--STRUCTURAL (HIGHLY
STRESSED MEMBERS), 6,1.1.1-- GROUP I WOOD , 6.5.5-- NO WANE IS PERMITTED,
LOADS OF LUMBER MUST BE INDIVIDUALLY WRAPPED WITH A TARP STYLE
MATERIAL, 14 FOOT LENGTHS ONLY
***NO EXCEPTIONS*** 750 EACH 7-DAYS $0.00
Plywood A/C, 1/2" x 48" x 96" Plywood, A/C, 1/2" x 48" x 96" 8,200 EACH 7-DAYS $0.00
Lumber 2" x 4" x 16'
Lumber, #2 or better graded, KD HT lumber
Material MUST FOLLOW;
ASTM D6199-07(2012), SPECIFICALLY: SECTION 6, 5.1 CLASS 1--STRUCTURAL (HIGHLY
STRESSED MEMBERS), 6,1.1.1-- GROUP I WOOD , 6.5.5-- NO WANE IS PERMITTED,
LOADS OF LUMBER MUST BE INDIVIDUALLY WRAPPED WITH A TARP STYLE
MATERIAL, 16 FOOT LENGTHS ONLY
***NO EXCEPTIONS*** 852 EACH 7-DAYS $0.00
Lumber 1" x 4" x 16'
Lumber, #2 or better graded, KD HT lumber
Material MUST FOLLOW;
ASTM D6199-07(2012), SPECIFICALLY: SECTION 6, 5.1 CLASS 1--STRUCTURAL (HIGHLY
STRESSED MEMBERS), 6,1.1.1-- GROUP I WOOD , 6.5.5-- NO WANE IS PERMITTED,
LOADS OF LUMBER MUST BE INDIVIDUALLY WRAPPED WITH A TARP STYLE
MATERIAL, 16 FOOT LENGTHS ONLY
***NO EXCEPTIONS*** 388 EACH 7-DAYS $0.00
Plywood CCX, 1/2" x 48" x 120" Plywood, CCX, 1/2" x 48" x 120" 2,000 EACH 7-DAYS $0.00
$0.00
QUOTE DATE:
Estimated Response Date: 16 April 2018 @ 12:00PM CST