96-Capillary Array Cartridge 50 um (ID) 33 cm (EFF), 55 cm (TOT), 10mL (RES) Part # A2300-9650-3355

• For use on the Fragment Analyzer system

• Must include 96 Capillaries

• Must be replaceable

• Must contain capillaries of 33 cm (EFF) in length or longer

• Must contain capillaries with 50um (Inner Diameter) or larger

48-Capillary Array Cartridge 50 um (ID) 33 cm (EFF), 55 cm (TOT), 10mL (RES) Part # A2300-4850-3355

• For use on the Fragment Analyzer system

• Must include 48 Capillaries

• Must be replaceable

• Must contain capillaries of 33 cm (EFF) in length or longer

• Must contain capillaries with 50um (Inner Diameter) or larger

Capillary Storage Solution, 100 ml Bottle Part # GP-440-0100

• For use on the Fragment Analyzer system

• A proprietary mixture of Glycerine (CAS: 56-81-5) required to keep capillaries on a Fragment Analyzer properly humidified between runs

Gasket Kit Part# G2938-68716

• Must include 1 syringe adapter

• Must include 10 gaskets

• Must include 1 mounting ring

• Must be compatible with Bioanalyzer Chip Priming Station

Chip Priming Station Part # 5065-4401

• For use with the Bioanalyzer quantification system

• Must include priming station, stop watch and 1 syringe clip

• Must be compatible with Agilent DNA and RNA assay chips dsDNA Reagent Kit, 75-15,000 bp (500 samples) Part # DNF-920-K0500

• For use on the Fragment Analyzer system

• Provides sizing and qualitative analysis of PCR fragments up to 15,000bp

• Sizing Range: 75 bp – 15,000 bp (defined by lower/upper marker)

• Input Concentration Range: 0.5 ng/μL – 50 ng/μL

High Sensitivity NGS Fragment Analysis Kit (1 bp - 6000 bp), (500 samples) Part # DNF-474-0500

• For use on the Fragment Analyzer system

• Provides sizing and quantitative analysis of NGS libraries

• Sizing Range: 25 bp – 5,000 bp

• Input Concentration Range: 50 pg/μL – 5 ng/μL

Standard Sensitivity NGS Fragment Analysis Kit (1 bp - 6000 bp), (500 samples) Part # DNF-473-0500

• For use on the Fragment Analyzer system

• Provides sizing and quantitative analysis of NGS libraries

• Sizing Range: 25 bp – 5,000 bp Input Concentration Range: 5 ng/μL – 100 ng/μL

Large NGS Fragment Analysis Kit, (500 samples) Part # DNF-492-0500

• For use on the Fragment Analyzer system

• Provides sizing and quantitative analysis of NGS libraries with large fragments

• Sizing Range: 50 bp – 20,000 bp

• Input Concentration Range: 5 ng/μL – 100 ng/μL

High Sensitivity Large Fragment Analysis Kit, (500 or more samples) Part # DNF-464-0500

• For use on the Fragment Analyzer system

• Provides sizing and quantitative analysis of NGS libraries with large fragments

• Sizing Range: 75 bp – 48,500 bp dsDNA 935 Reagent Kit, 1-1,500 bp (500 samples) Part # DNF-935-K0500

• For use on the Fragment Analyzer system

• Provides sizing and qualitative analysis of PCR fragments up to 1,500bp

• Allows for fast separation in under 20 minutes

• Sizing Range: 1 bp – 1,500 bp (defined by lower/upper marker)

High Sensitivity Large NGS Fragment Analysis Kit, (500 samples) Part# DNF-488-0500

• For use on the BioAnalyzer system

• Provides sizing and quantitative analysis of NGS libraries with large fragments

• Sizing Range: 100 bp – 7500 bp

Agilent DNA 7500 Kit, (300 samples/25 chips) Part# 5067-1506

• For use on the Fragment Analyzer system

• Provides sizing and quantitative analysis dsDNA

• Sizing Range: 75 bp – 20,000 bp

Agilent DNA High Sensitivity DNA Kit, (110 samples/10 chips) Part# 5067-4626

• For use on the Fragment Analyzer system

• Provides sizing and quantitative analysis dsDNA

• Sizing Range: 50 bp – 7,000 bp

Agilent DNA 12000 Kit, (300 samples/25 chips) Part# 5067-1508

• For use on the Fragment Analyzer system

• Provides sizing and quantitative analysis dsDNA

• Sizing Range: 100 bp – 12,000 bp

Agilent Protein 230 Kit, (250 samples/25 chips) Part# 5067-1517

• For use on the Fragment Analyzer system

• Provides sizing and quantitative analysis dsDNA

• Quantitative Range: 15-2000 ng/μL

Herculase II Fusion Polymerase (200rxn) Part# 600677

• Must be formulated to amplify difficult GC rich targets

• Must include dNTPs

PfuTurbo Cx Hotstart DNA Polymerase Part # 600414

• Must be a mutant Pfu polymerase designed to overcome Uracil sensitivity

ALS Main Cable Assembly Part # G4514-60610

• Shall be compatible with series 7693 automated liquid sampler systems

1290 Infinity II in-line filter, 0.3 um, 2mm ID, SST. Max 1300 bar Part # 5067-6189

• Shall be compatible with series 7693 automated liquid sampler systems

Bond Elut Plexa PCX Cartridge, 30 mg, 3mL, 500/pk Part # 12108303B

• Shall be suitable for polar and nonpolar basic analytes

Column nut, collared, self-tightening, inlet/detector Part # G3440-81011

• Shall be compatible with Agilent gas chromatography systems

Column nut, collared, self-tightening, MSD Part # G3440-81013

• Shall be compatible with Agilent gas chromatography systems

FID jet, universal fit, 0.011 inch id Part # 5200-0176

• Shall be compatible with Agilent Flame Ionization Detectors

InfinityLab Quick Connect Fitting assembly with pre-fixed 0.12 x 105mm capillary Part # 5067-5957

• Shall be compatible with Agilent Liquid Chromatography/Mass Spectrometry systems

Inlet liner, splitless, straight Part # 210-3003-5

• Shall be compatible with gas chromatography columns

NPD Jet, universal fit, 0.011 inch ID Part # 5200-0179

• Shall be compatible with Agilent Gas Chromatography systems

Needle support insert, standard, 7693 Part # G4513-40525

• Shall be compatible with Agilent Autosamplers

High Sensitivity Large Fragment Analysis Kit, (500 or more samples)
Part # DNF-464-0500
For use on the Fragment Analyzer system
Provides sizing and quantitative analysis of NGS libraries with large fragments
Sizing Range: 75 bp – 48,500 bp
Input Concentration Range: 50 pg/μL – 5 ng/μL
Shall be compatible with series 7693 automated liquid sampler systems
Shall be compatible with series 7693 automated liquid sampler systems
Shall be suitable for polar and nonpolar basic analytes
Shall be compatible with Agilent gas chromatography systems
Shall be compatible with Agilent gas chromatography systems
Shall be compatible with Agilent Flame Ionization Detectors

File details come from the government source that posted it. Updated .