FM50 Mask
The M50 Joint Services General Purpose Mask provides outstanding protection from battlefield concentrations of
CB agents, toxic industrial materials, toxic chemicals, and particulate matter.
Visor Technology
Polyurethane visor is highly flexible plus scratch and impact resistant
Optically correct across the whole field of view
Panoramic visor design gives excellent field of vision and wearer recognition while enhancing compatibility with weapon sights
Vision correction system allows prescription lenses to be mounted inside the mask
Clear outserts for extreme environments
Sunlight outserts for high intensity light situations
BlueBocker outsert delivers sharper images by filtering out specific light wavelengths
Laser Outserts for protection against specific wavelengths
Air Flow Management
Heat buildup minimized
Low inhalation resistance]
Low re-breathed carbon dioxide
Excellent de-mist properties
User Benefits
High degree of flexibility and comfort for extended use
Head harness eliminates pressure points
Advanced reflex seal for helmet compatibility
Extended chin flap for garment compatibility
High flow fail safe drinking device enables connection to a canteen or bladder type system
Second-skin hood/mask interface allows mask to integrate with the Gore Chempak material protective hood
Communications
Provides clear communication while wearing mask
Electronic Communication Port allows an Audio Amplifier to be safely connected in a CBRN environment to an internal microphone
Additional communication systems can be attached via this ECP using an appropriate lead
Filtration
Twin filter design significantly reduces breathing resistance and improves weight distribution
Bayonet fit provides quick and efficient filter attachment
Filters can be replaced without breaking the protective seal through self-sealing valves
Conformal filter technology improves integration with equipment
CBRN Agent Resistance M50 Performance
Mustard (H) Greater than 36 Hours
Sarin (GB) Greater than 36 Hours
Soman (GD) Greater than 36 Hours
VX Greater than 36 Hours
Laboratory Protection Greater than 10,000
Factory Performance Greater than 10,000
(Sodium Chloride)
Re-breathed Carbon Dioxide 0.8%
Inhalation Resistance at: Mask Only Mask & Filter
30 L/Min 2 mm WG 10 mm WG
95 L/Min 8 mm WG 30 mm WG
160 L/Min 12 mm WG 64 mm WG