AH-64 Wire Test Equipment Statement of Work:

This statement of work is for a contractor to provide Ditmco testing equipment to support the workload for the AH-64 helicopters.

1. The contractor shall provide 10 qty- Model #2650 MTA (Part Number 111-03109-8101).

2. The contractor shall provide 110 qty- Series Switching Cards (Part Number 141-02237-8001).

3. The contractor shall provide 3 qty. Portable Lowboy Switching Carts (Part Number 121-04143-0001).

4. The contractor shall provide 1 qty. of this item-SMU 1.5KVDC 1KVAC RC PCA (Ref: 141-02284-

0003) (141-02284-0003 which is a direct replacement for 141-02207-0003, form fit and function).

5. The contractor shall provide 1 qty of this item HVC OPTIONS W/O AC PCA (Reference: 141-

02273-0002).

6. The contractor shall provide 1 qty. of this item NETLINK ANALYZER CONTROLLER PCA

(Reference: 141-02261-0002).

7. The contractor shall provide 25-qty- Daisy chain interconnect cable, 5 feet.

8. The contractor shall provide 3 qty - Daisy chain interconnect cable, 10 feet.

9. The contractor shall provide 3 qty -Daisy chain interconnect cable, 20 feet.

10. The contractor shall ship these items to the:

W91CAT Corpus Christ Army Depot 540 First St, SE Bldg. 1846

MS 5#, 361-961-4674

Corpus Christi, TX 78419.

Master Switching Unit/ Switching Card

Provides up to 1,500 points of switching in 50 point increments Expandable switching: 15,000 points per segment Test Speed: Up to 3,000 tests per minute Discharge wait circuit prevents switching from actuating with stimulus applied

Operating Conditions

Relative humidity: 30% - 80% (Relative humidity non-condensing) Indoor application Altitudes up to 2000m Standard configuration temperatures: 60°F - 90°F (15°C - 32°C) 100-110VAC/30A Twist Lock, 1 phase 50Hz

Additional Instrumentation Option

AC breakdown detector 1000VDC

Standard Instrumentation / Standard Measurement Unit

System accuracy Continuity ±1% Insulation ±3%

Fully programmable Voltage stimulus up to 1500VDC Current stimulus up to 2A Continuity resistance 0.01 to 99K Insulation up to 1000M

Four-wire resistance measurement from 0.01 to 10 Floating instrument Capacitance measurements 10pF - 5000µ F Simultaneous insulation and hipot testing DC dielectric (hipot) currents of 0.5mA 2.5mA DC voltage measurement AC voltage measurement (true RMS)

Modular Test Analyzer, Model # 2650.MTA for AH-64 helicopters shall be applied to perform the work requirements stated below:

To verify and/or locate faults diagnosed in aircraft wiring and associated components To complete the Program Executive Office (PEO) assigned work on AH-64 helicopters which includes AH-64 upgraded to the AH-64D configuration Test equipment shall conform to wire test requirements specified by the customer

Technical point of contact: David Flores, General Engineer, GS-12, (361) 961-4674

Certification: It is certified that this justification is current, accurate and complete to the best of my knowledge. Applicable documentation will be provided on request.

Date: 01 April 2019