Questions and Answers.xlsx

XLSX spreadsheet 8 MB Posted

Attached to
GVSC Lab Calibration
Solicitation number
W56HZV-22-R-L009
Issued by

View the file

Other files

File Type Posted
W56HZV-22-R-L009 Amendment 0001.pdf PDF
Exhibit A CDRLs.DOC DOC document
W56HZV-22-R-L009.pdf PDF
Attachment 0001 GFPM.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

CommentAttachmentsAsset #ManufacturerModel NumberDescriptionCalibration LevelQtyInternal Notes/Network Lab
Calibrate PSL00277 and PSL01367 as system with water, 6 points (0 to 240) GPMPSL00277EG&G FlowmeterFT-48NEYWRLEG-2Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
Air flowPSL01832Endress Hauser651-4OAAOAE1PABBBAMass Flow MeterAccredited 170252Need to know the type of gas or air the customer is measuring with this meter for both pricing and caps.
Last calibrated in "Oil Blend"PSL00550Flow TechnologiesFT-08AENS-LAA-2Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
Last calibrated in "Heptane" PSL01796PSL01796Flow TechnologiesFT-10AEXSRLEB-1Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
Last calibrated in "Oil Blend" PSL01455PSL01455Flow TechnologiesFT-12AEU2-LEA-1Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
Last calibrated in Oil Blend. (note Service:Royco 756 hydraulic fluid from 100- 150F viscosity curve. Oil is rated at 102 F=13.9 cST, 212 F= 5.13 cST)PSL00891Flow TechnologiesFT-12AEU2-LEAT1Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
PSL01483 Last calibration was done in Water.PSL00270Flow TechnologiesFT-12AEYW-LEG-2Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
PSL00548 Last calibration was done in "oil blend"PSL00548Flow TechnologiesFT-16AENB-LEA-2Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
(PSL00450? Last calibrated in water)(PSL00817? Last calibrated in Oil BlendPSL00450Flow TechnologiesFT-16AEU4-LEG-1Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
(PSL02070? was last calibrated in water)(PSL01972? Last calibrated in oil blend)PSL01792Flow TechnologiesFT-16AEYS-LEB-1Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
(PSL02070? was last calibrated in water)(PSL01972? Last calibrated in oil blend)PSL02070Flow TechnologiesFT-16AEYS-LEB-1Flow MeterAccredited 1702550Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
PSL01732 last calibrated in Ethylene GlycolPSL01732Flow TechnologiesFT-40HBXS-LEB-1Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
To be calibrated with mobil jet oil 254 with the following parameters. calibrated for

05GPM. Viscosity at 100 degrees C is 5.3 mm^s. Viscosity at 40 degrees C is 26.4mm^2/s. Range of temperature seen during testing is 160 degrees F.

Calibrations must havePSL00252Flow TechnologiesFT6-8AEU2-LEAT-1Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
calibrate with waterPSL01798Flow TechnologiesFT6-8AEXS-LEB-1Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
calibrate with waterPSL01458Flow TechnologiesFT8-8AEXS-LEB-1Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
These signal conditioners are paired with a FTI flowmeter.PSL01367Flow TechnologiesLA-5-A-MAB7Signal ConditionerAccredited 170251Lab will need to see. Believe this is calibrated with the Flow meter
These signal conditioners are paired with a FTI flowmeter.PSL01800Flow TechnologiesLA-5-C-MAB6Signal ConditionerAccredited 170251Lab will need to see. Believe this is calibrated with the Flow meter
These signal conditioners are paired with a FTI flowmeter.PSL01802Flow TechnologiesLA-5-C-MAB6Signal ConditionerAccredited 170251Lab will need to see. Believe this is calibrated with the Flow meter
These signal conditioners are paired with a FTI flowmeter.PSL01463Flow TechnologiesLA-5-C-MAB7Signal ConditionerAccredited 170251Lab will need to see. Believe this is calibrated with the Flow meter
These signal conditioners are paired with a FTI flowmeter.PSL01480Flow TechnologiesLA-5-C-MAB7Signal ConditionerAccredited 170251Lab will need to see. Believe this is calibrated with the Flow meter
These signal conditioners are paired with a FTI flowmeter.PSL01481Flow TechnologiesLA-5-C-MAB7Signal ConditionerAccredited 170251Lab will need to see. Believe this is calibrated with the Flow meter
These signal conditioners are paired with a FTI flowmeter.PSL00816Flow TechnologiesLAT-3-C0-MAB7Signal ConditionerAccredited 170251Lab will need to see. Believe this is calibrated with the Flow meter
These signal conditioners are paired with a FTI flowmeter.PSL00906Flow TechnologiesLAT-3-C0-MAB7Signal ConditionerAccredited 170251Lab will need to see. Believe this is calibrated with the Flow meter
These signal conditioners are paired with a FTI flowmeter.PSL00907Flow TechnologiesLAT-3-C0-MAB7Signal ConditionerAccredited 170251Lab will need to see. Believe this is calibrated with the Flow meter
These signal conditioners are paired with a FTI flowmeter.PSL01551Flow TechnologiesLNT-3-CO-MAB7Signal ConditionerAccredited 170251Lab will need to see. Believe this is calibrated with the Flow meter
Remove from proposal and enter "$0.00" in the pricing sheetAFL00042JMS3ESBK12"BWP3-36"AYTATemperature ProbeAccredited 170257Unable to locate on search. Need specifications sheet to review for bothpricing and caps.
See attachmentPSL01966MTS Systems Corporation9210DCal StandardAccredited 170251Unable to locate on search. Need specifications sheet to review for bothpricing and caps.
1mg to 200mgFLL00314None1MG-200GMWeight SetAccredited 170251Need the capacity of each weight in set and class for pricing.
Liquid type is a 50/50 solution of "Peak" ethylene glycol coolant and distilled waterECL00214OmegaFTB4805Flow MeterAccredited 170256Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
Liquid type is a 50/50 solution of "Peak" ethylene glycol coolant and distilled waterECL00189OmegaFTB4810Flow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
See attachmentVEA00126Rohde & Schwarz5011.6559K02Calibration Kit, 2.92 mmAccredited 170251Need specifications sheet to review for bothpricing and caps.
See attachmentPSL00660SchlumbergerVF61S00-NNNNNNNFlow MeterAccredited 170251Need specifications sheet to review for bothpricing and caps.
AirFLL00506Seta AnalyticsFGTF 3AHDFlow MeterAccredited 170251Need to know the type of liquid the customer is measuring with this meter for both pricing and caps.
1mg to 5kgAFL00137TBD27 Piece Class 1 Weight SetCalibration WeightAccredited 170251Need a breakout of the capacity of each weight in set for pricing.

,-..;Certificate of Calibration,-..;

Manufacturer: _____ T_h_e_M_o_d_al_S_l_10 ..... p ___ _ Calibration Date: 30-Aug-19

Model Number: 9210D Calibration Due: ---------------Serial Number: 30275 --------------- Temperature: 73.7 OF Des c rip ti on: Portable Vibration Calibrator --------------- 23.2 oc

Test Procedure: PRD-P278 --------------- Humidity: 48.7 %

Calibration Tech: LIB ~ ---------------Customer:

Internal Reference As found: In Tolerance As left: In Tolerance Sensitivity@ 100 Hz: __ 9_8._3_6_mV/g

(Measured at Monitor Refe rence Out BNC)

Rt E e erence ;qmpment:

Manufactu11er Description Model Number Serial Numt,er Due Date

PCB Std Sens Q353B51 167579 2-May-20 National Inst Data Acqu isition USB-4431 1941062 5-Dec-19

PCB Signal Conditioner 443B101 432 24-Apr-20

Standard Sensor Unit Under, Test % difference

Frequency Measured Refe~ence Displayed .Displayed Acceleration Sensitivity

Hz Acceleration (g Sensitivity Acceleration Sensitivity (Displayed (Display eel

pk) (mV/g) (g pk) (mV/g) /Measured) /Reference)

0.7 0.010 481 .76 0.01 0 4958.30 -1.97% 2.92%

0.8 0.012 482.1 2 0.012 4874.20 1.28% 1.1 0%

0.9 0.014 482.48 0.014 4789.50 0.59% -0.73% 1 0.021 482.71 0.020 4893.90 2.54% 1.38%

2 0.05 484.66 0.05 4856.90 0.84% 0.21%

5 0.40 486.87 0.40 485.93 0.11% -0.19%

10 1.00 488.1 4 1.00 487.72 0.21% -0.09%

15 1.00 488.91 1.00 488.08 0.05% -0.1 7%

30 1.00 489.81 1.00 488.81 0.05% -0.20%

50 1.00 490.31 1.00 488.83 -0.06% -0.30%

100 1.00 491 .00 1.00 490.58 0.19% -0.09%

200 1.01 490.74 1.00 491 .52 0.51% 0.16%

500 1.00 492.55 1.00 492.27 0.08% -0.06%

1000 1.00 493.90 1.00 493.59 0. 14% -0.06%

2000 1.00 498.34 1.00 499.51 0.47% 0.24%

Notes:

1. This document certifies that the above meets published specifications.

2. The equipment referenced above has been ca librated using standards traceable to NIST (Project Number 822/271196) and PTB (Project Number 5399). Evidence of traceability is on fi le at The Moda l Shop.

3. The results documented in this certificate re late only to the items tested or calibrated.

4. This certificate may not be reproduced, except in fu ll, without the written consent of The Modal Shop, Inc.

5. Measurement uncertainty (95% confidence level with coverage factor 2) fo r frequency ranges tested during calibration are as fo llows: 7<10 Hz; ±4.0%, 10<30 Hz;± 3.0%, 30<100 Hz;± 1.5%, 100 Hz;± 1.5%, 100<2000 Hz;± 1.5%, 2000-10,000 Hz; ± 4.0%.

6. Dispalyed sensitivity from 0.7 - 2 Hz is gained up by 10x.

[!l] THE MODAL SHOP

MTS SYSTEMS CORPORATION

PRD-F267 revNR 04/30/18 Calibration ID: 8/30/19 12:41

The Modal Shop Inc.

3149 East Kemper Road

Cincinnati, Ohio 45241

+1-513-351-9919 www.modalshop.com

PSL01966

michael.trombley

Highlight michael.trombley

Sticky Note

Initial cal from Mfr. Unit operational upon rcpt with no damage and released for use.

,-._;Certificate of Calibration,-._;

Manufacturer: _____ T_h_e_M_o_d_a_l _S_ho_.p.__ ___ _ Calibration Date: 30-Aug-19

Model Number: 9210D Calibration Due: ---------------Serial N umber: 30275 - -------------- Temperature: 73.7 OF Des c rip ti on: Portable Vibration Calibrator --------------- 23.2 oc

Test Procedure: PRD-P278 --------------- Humidity: 48.7 %

Calibration Tech : LJB

Customer:

Internal Reference As found: In To lerance As left: In Tolerance Sensitivity@ 100 Hz: 10.03 mV/ m/s2

(Measured a:t Monitor Refe rence Out BNC)

Rt e erence ,qmpmen: E t Manufacturer Description Model Number Serial Number Due Date

PCB Std Sens Q353B51 167579 2-May-20 National Inst Data Acquisition USB-4431 1941062 5-Dec-19

PCB Signal Conditioner 443B101 432 24-Apr-20

Standard Sensor Unit Under Test 0/c, difference

Measured Reference Displayed Displayed Acceleration Sensitivit)' Frequency Acceleration Sensitivity Acceleration Sensitivity (Displayed (Displayed

(m/s2) (mV/m/s2) (m/s2) (mV/m/s2) /Measured) /Reference)

0.7 0.10 49.13 0.10 505.61 -1 .97% 2.92%

0.8 0.12 49.16 0.12 497.03 1.28% 1.10%

0.9 0.1 4 49.20 0.14 488.39 0.59% -0.73%

1 0.20 49.22 0.20 499.04 2.54% 1.38%

2 0.49 49.42 0.49 495.27 0.84% 0.21%

5 3.93 49.65 3.92 49.55 0.1 1% -0.19%

10 9.83 49.78 9.81 49.73 0.21% -0.09%

15 9.81 49.86 9.81 49.77 0.05% -0.17%

30 9.81 49.95 9.81 49.84 0.05% -0.20%

50 9.80 50.00 9.81 49.85 -0.06% -0.30%

100 9.83 50.07 9.81 50.03 0.19% -0.09%

200 9.86 50.04 9.81 50. 12 0.51% 0. 16%

500 9.81 50.23 9.81 50.20 0.08% -0.06%

1000 9.82 50.36 9.81 50.33 0.14% -0.06%

2000 9.85 50.82 9.81 50.94 0.47% 0.24%

1. This document certifies that the above meets publ ished specifi cations.

2. The equipment referenced above has been calibra ted using standards traceable to NIST (Project Number 822/271196) and PTB (Project Number 5399). Evidence of traceability is on fi le at The Modal Shop.

3. The results documented in this certificate relate only to the items tested or calib rated.

4. This certifi cate may not be reproduced, except in ful l, without the written consent of The Modal Shop, Inc.

5. Measurement uncertainty (95% confidence level with coverage factor 2) for frequency ranges tested during calibration are as follows : 7<10 Hz; ±4.0%, 10<30 Hz;± 3.0%, 30<100 Hz;± 1.5%, 100 Hz; ± 1.5%, 100<2000 Hz;± 1.5%, 2000-10,000 Hz;± 4.0%.

6. Dispalyed sensitivity from 0.7 - 2 Hz is gained up by 1 Ox.

rIJ THE MODAL SHOP

MTS SYSTEMS CORPORATION

PRD-F267 revNR 04/30/18 Calibration ID: 8/30/19 12:41

+1-513-351-9919

,....,Certificate of Calibration,...., Manufacturer: _____ T_h_e_M_ o_d_a_l _S_ho~P~---- Calibration Date: l 7-Sep- 19 Model Number: 9210D Calibration Due: ------ - - - ----- -Seri a I Number: 30275 Temperature: 73.0 OF

---------------Des c rip ti on: ___ P_o_rt_a_b_le_V_1b_r_a_t1_· o_n_C_al_ib_r_a_to_r __ 22.8 oc Test Procedure: PRD-P295 --------------- Humidity: 47.2 %

Calibration Tech: BTH 6-~ 9+-a--~

---------------Customer: ---------------

Internal Reference As found : In Tolerance As left: In Tolerance Sensitivity@ 100 Hz: __ 9_8_.4_2_ mV/g

(Measured at Monitor Reference Out BNC)

Rf E e erence ;qmpment:

Manufacturer Description Model Number Serial Number Due Date

PCB Std Sens 353B02 162795 6-Dec-19 HP DMM 34401A MY47065049 24-Jan-20

PCB Signal Cond itioner 482B11 5972 6-Dec-19

Standard Sensor Unit Under Test % -difference

Measured Reference Displayed Displayed Acceleration Sensitivity

Acceleration Sensitivity Acceleration Sensitivity (Displayed (Displayed

(g pk) (mV/g) (g pk) (mV/g) /Measured) /Reference)

5 0.499 199.91 0.499 198.95 -0.01% -0.48%

7 1.000 19.98 0.999 20 .17 0.04% 0.95%

10 0.997 20 .05 1.000 20.18 -0.30% 0.67% 15 0.999 20 .01 1.000 20.19 -0.13% 0.91%

30 0.998 20 .02 1.002 20. 19 -0.39% 0.83%

50 1.001 20 .03 1.002 20.26 -0 .09% 1.14%

100 1.001 20.05 0.999 20.26 0 .21% 1.07%

160 1.003 20.05 1.000 20.26 0.34% 1.02%

300 1.004 20.06 1.000 20.35 0.48% 1.45%

500 1.003 20.09 1.000 20.32 0.31% 1.15%

1000 1.007 20.12 1.000 20.34 0.69% 1.11%

2000 1.015 20.15 1.000 20.45 1.49% 1.49%

1. This document cert ifi es that the above meets publ ished specificat ions.

2. Traceability is to the Helium-Neon laser as an intri ns ic standard. Proficiency in the method has been validated by Physikalisch-Technische Bundesanstalt (PTB) (under proj ect 170 14 and 17004) and to The National Institute of Standards and Technoloby (NIST) (under project 683/287323) .

3. The results documented in this certificate relate on ly to the items tested or calibrated.

4 . This certificate may not be reproduced, except in fu ll, without the written consent of the manufacturer.

5. Measurement uncertainty (95% confidence level with coverage fac tor 2) for frequency ranges tested during calibration are as follows : 7< IO Hz; ±4.0%, I 0<30 Hz;± 3.0%, 30< I 00 Hz; ± 1.5%, I 00 Hz;± 1.5%, l 00<2000 Hz;± 1.5%, 2000-10,000 Hz;± 4 .0%.

6. Frequencies below 7 Hz are not A2LA accredited.

7. Displayed sensit ivity at 5 Hz uses 1 OX gain.

D i:rJTHEMODALSHOP [A'cciiEDITED) MTS SYSTEMS CORPORATION

Calibration Laboratory Certificate Number 2649-01 PRD-F281 revB 8/9/19 Calibration ID: 9/17/19 9:03

+ 1-513-351-9919 www.rnodalshop.com

,...,Certificate of Calibration,..., Manufacturer: _____ T_h_e _M_o_d_a_l_S_h_o~p ___ _ Calibration Date: 17-Sep-19

Model Number: 9210D Calibration Due: ----------------Seri a I Number: 30275 ---------------- Temperature: 73 .0 OF Des c rip ti on: ___ P_o_rt_a_b_le_V_ ib_r_at_i_o1_1 _C_a_li_b_ra_t_or __ 22.8 oc

Test Procedure: PRD-P295 Humidity: 47.2 %

Calibration Tech: 8TH p~1J--o~

Customer: ----------------

Internal Reference As found : In Tolerance As left: In Tolerance Sensitivity@ 100 Hz: 10.04 mV/m/s2

(Measured at Monitor Reference Out BNC)

Rf E e erence ,qmpmen :

Manufacturer Descriotion Model Number Serial Number Due Date

PCB Std Sens 353B02 162795 6-Dec-19 HP DMM 34401A MY47065049 24-Jan-20

PCB Signal Conditioner 482B11 5972 6-Dec-19

Standard Sensor Unit Under Test % difference

Measured Reference Displayed Displayed Acceleration Sensitivity Frequency Acceleration Sensitivity Acceleration Sensitivity (Displayed (Displayed

~m/s2) (mV/m/s2) (m/s2) (mV/m/s2) /MeasuFed) /Reference)

5 4.89 20.39 4.89 20.29 -0.01 % -0.48%

7 9.80 2.04 9.80 2.06 0.04% 0.95% 10 9.78 2.04 9.81 2.06 -0.30% 0.67%

15 9.80 2.04 9.81 2.06 -0. 13% 0.91%

30 9.79 2.04 9.82 2.06 -0.39% 0.83%

50 9.81 2.04 9.82 2.07 -0.09% 1.14%

100 9.82 2.04 9.80 2.07 0.21% 1.07% 160 9.84 2.04 9.80 2.07 0.34% 1.02%

300 9.85 2.05 9.80 2.07 0.48% 1.45% 500 9.84 2.05 9.81 2.07 0.31% 1.15% 1000 9.87 2.05 9.80 2.07 0.69% 1.11% 2000 9.95 2.05 9.81 2.09 1.49% 1.49%

l. This document certifies that the above meets publ ished specifications.

2. Traceab ility is to the Helium-Neon laser as an intrinsic standard. Proficiency in the method has been validated by Physikalisch-Technische Bundesanstal (PTB) (under project 17014 and 17004) and to The National Institute of Standards and Technoloby (NIST) (under project 683/287323).

3. The results documented in this certificate relate only to the items tested or calibrated.

4. This certificate may not be reproduced, except in fu ll, without the wri tten consent of the manufacturer.

5. Measurement uncertainty (95% confidence level with coverage factor 2) for frequency ranges tested during calibration are as follows: 7<10 Hz; ±4.0%, 10<30 I-Iz; ± 3.0%, 30<100 Hz; ± 1.5%, 100 Hz;± 1.5%, 100<20001-lz; ± 1.5%, 2000-10,000 Hz;± 4.0%.

6. Frequencies below 7 Hz are not A2LA accredited.

7. Displayed sensitivity at 5 Hz uses I OX gain.

D [JJ THE MODAL SHOP

(Acc'i!eDITED] MTS SYSTEMS CORPORATrON

Calibration Laboratory Certificate Number 2649-01 PRD-F281 revB 8/9/19 Calibration ID: 9/17 /19 9:03

+ 1-513-351-9919

2020-12-07T14:18:11-0500

TROMBLEY.MICHAEL.ROY.1210733473

image1.emf

C

CD C C

C-

PF

.4

0.

V

.O

O

0 m C -1 0) 0 I m ;tJ

SD (p C

C = C

CD C-

CD = C

CD CD C

HDE &SCHWARZ

Messgerãtebau GmbH akkreditiert durch die I accredited by the

Kalibrierschein Calibration certificate

P.-

((iAiks

Deutsche ... Akkreditierungsstelle

D-K-15195-O1-OO

D-K

Kalibrierzeichen 151950100

Calibration mark 2017-08

101035

Detroit Arsenal RDTA-RS Scott Faust! W56HZV-17-F-L227

RDTA-RS/ M/S 224

6501 E Eleven Mike Rd Bldg 200E WARREN Ml 48397

US

4950052947

Dieser Kalibrierschein dokumentiert die Rück fuhrung auf nationale Normale zur Darstellung der Einheiten in Obereinstimmung mit dem Internationalen Einheitensystem (SI).

Die DAkkS st Unterzeichner der multilateralen Ubereinkommen der European co-operation for Accreditation (EA) und der International Labora tory Accreditation Cooperation (ILAC) zur ge genseitigen Anerkennung der Kalibrierscheine.

Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer vera ntwortlich.

This calibration certificate documents the traceability to national standards, which realize the units of measurement according to the International System of Units (SI).

The DAkkS is signatory to the multilateral agreements of the European co-operation for Accreditation (EA) and of the International Laboratory Accreditation Cooperation (ILAC) for the mutual recognition of calibration certifica tes.

The user is obliged to have the object recall-brated at appropriate intervals.

Datum der Kalibrierung Date of calibration

2017-08-09

Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Anderungen bedürfen der Genehmigung sowohl der Deutschen Akkreditierungsstelle GmbH als auch des ausstellenden Kalibrierlaboratoriums. Kalibrierscheine ohne Unterschrift haben keine Gültigkeit.

This calibration certificate may not be reproduced other than in full except with the permission of both the Deutsche Akkreditierungsstelle GmbH and the issuing laboratory. calibration certificates without signature are not valid.

Datum SteIIv. Leiter des Kalibrierlaboratoriums earbeiter Date Vice Head of the calibration laboratory person in a e

2017-08-09 Lu Gü 4Jocham Robert Knobloch

Rohde & Schwarz MessgerStebau GmbH • Rohde-und-Schwarz-Str. 1 . 87700 Memmingen • Telephone national: 08331/10-80 international: 0049 8331/10-80 Fax: 08331/10-811 24 • Managing Director:Jürgen Steigmuller • Chairman ofthe Supervisory Board: Manfred Fleischmann • Company’s Place of Business: München Commercial Register No.: HRB 1 059 • VAT Identification No.: DE 811 190 745

Deutsche Akkreditierungsstelle GmbH als Kalibrierlaboratorium im I as calibration laboratory in the

Deutschen Kalibrierdienst DKD

50 C) Type-2.92 mm Calibration Kit

Rohde & Schwarz

ZV-Z229

Gegenstand Object

Hersteller Manufacturer

Typ Type

Fabrikat/Serien-Nr.

Serial number

Aultraggeber customer

Auftragsn u m mer Order No.

Anzahl der Seiten des Kalibrierscheines Number ofpages of the certificate

Seite 2 I 13 D-K Page ROHDE&SCHWARZ 15195-01-00

Messgerätebau GmbH 2017-08

Ort der Kalibrierung Place of calibration

87700 Memmingen, Rohde-und-Schwarz-Str. 1

Umgebu ngsbedingu ngen Environmental conditions

Temperatur ( 23 ± 1 ) °C

Ambient temperature

Relative Feuchte ( 40 ± 20 ) %

Relative humidity

Messunsicherheit Measurement uncertainty

Angegeben st die erweiterte Messunsicherheit, die sich aus der Standardmessunsicherheit durch Multiplikation mit dem Erweiterungsfaktor k = 2 ergibt. Sie wurde gema DAkkS-DKD-3 ermittelt. Der Wert der Messgrö1e liegt mit einer Wahrscheinlichkeit von 95 % im zugeordneten Wertintervall.

The expanded measurement uncertainty corresponds to the measurement resultsfrom the standard measurement uncertain-ty multiplied by the caveragefactar k = 2. It was determined in accordance with DAkkS-DKD-3. The true value is located in the corresponding interval with a probability of95 %.

Anerkennung der Kalibrierscheine im Ausland Recognition ofcalibration certificate inforeign countries

Die Deutsche Akkreditierungsstelle GmbH st Unterzeichner der multilateralen Obereinkommen der European co-operation for Accreditation (EA) und der International Laboratory Accreditation Cooperation (ILAC) zur gegenseitigen Anerkennung der Kalibrierscheine. Die weiteren Unterzeichner innerhalb und auRerhalb Europas sind den Internetseiten von EA (www.european-accreditation.org) und ILAC (www.ilac.org) zu entneh men.

The Deutsche Akkreditierungsstelle GmbH is signatory of the Multilateral Agreement of the European cooperation for Ac-creditation (EA) and of the International Laboratory Accreditation Cooperation (ILAC) for the mutual recognition of the cali bration certificates. The further signatories within and outside of Europe can be gathered from the Internet sites from EA (www. european-accreditation. org) and ILAC (www.ilc.org).

Seite 3 I 13 4:$: [ D-K Page ROH DE & ScHWARZ [15195-01-00

Messgerätebau GmbH [917-08

Kalibriergegenstand Object

ZV-Z229 50 0 Type-2.92 mm Calibration Kit Frequency range DC to 40 GHz Open Male and Female Short Male and Female Match Male and Female Three Type 2.92 mm to Male-Male, Female-Female and Male-Female Type 2.92 mm adaptors

Kalibrierverfahren Calibration procedure

Reflection The measurement was performed using a vector network analyzer, calibrated with a calibra tion-kit. The exact function and the given uncertainty of measurement is controlled by a working standard that is traceable to a transfer standard.

Phase The measurement was performed using a vector network analyzer, calibrated with a calibra

Attenuation The measurement was performed using a vector network analyzer, calibrated with a calibra

Messbedingungen Measurement Conditions

The standards was measured at different rotated coaxial positions. The result is the arithmetic mean value of individual series of measurements.

Messergebnisse Measurement Results

The scope of calibration is reflection, phase and attenuation.

Konformitätserklärung Statement of compliance

Incoming New device.

Outgoing All measured values are within the data sheet specifications.

Anmerkungen Notes

Filename on Data storage : see page 13 2.1

Gebrauchsnormale Working Standards

Gegenstand Typ Serien Nr.

Object Type Serial-No.

Vector Network Analyzer ZNB4O 101512 Calibration Kit 8770C 1204

Type ZV-Z229 Serial No. 101035 0179

Test System DKD_PC11 MaterialNo. 5011.6559K02 D-K- ROHDE&SCHWARZTemperature (23 -11+1 ) C Date 201 7-08-09

File (Outgoing) 501 1 .6559K02_1 01 035_i OD.MF 201 7 08

Page 4/13

Table of contents

1. ZV-Z229Calibration K1t2.92 mm 5

1.1 Phase OPEN ( F) Ser.Nr. 102384 6

1.2 Phase SHORT( F ) Ser.Nr. 102423 7

1.3 MATCH(F) Ser.Nr.102350 8

1.4 Phase OPEN ( M ) Ser.Nr. 102284 9

1.5 PhaseSHORT(M) Ser.Nr.102302 10

1.6 MATCH(M ) Ser.Nr.102427 11

1.7 THROUGH (FF) Ser.Nr. 102331 12

1.8 THROUGH (FF) 12

1.9 THROUGH (MM ) Ser.Nr. 102404 13

1.10 THROUGH(MM) 13

2. Filename on Data storage

2.1 FNedescription

Test System

Temperature

File (Outgoing)

Page

DKD_PC1 1

(23 -11+1 )C

501 1.6559K02_101035_1OD.MF

5/13

I . ZV-Z229 Calibration Kit 2.92 mm

OPEN [ F I

Connector Ca1KIt

Ser.Nr.

StartFreq StoppFreq

Loss

Offset length

CO

Cl C2 C3

OPEN [ M I

CalKit Ser . Nr.

$tartFreq

SHORT [ F I

SHORT [ K I

2.92 mm

102384

0 Hz 40000000000 Hz

0 . 01199998 8 . 69398128

46.78376000 0 . 26997100

-0 01285500 0.00038600

102423

0 . 01300016 9 . 34513050 5.64973600

Ll -0.29553600 L2 0.01549200 L3 -0.00027700

102302 dB/sqrt (GHz) mm fF f F/GHz fF/GHz 3 pH pH/GHz pH/GHz2

Serial No.

Material No.

Date

501 1.6559K02 201 7-08-09

ROHDE &SCHWARZ

102284

0 . 01199999 8 . 69997713

43.64233000 0 . 55711500

-0.02834800 0.00065000 fF fF/GHz fF/GHz 3

LO

Loss 0.01200015 dB/sqrt(GHz) Offset length 9.34513050 mm

LO 8.00580400 pH Ll -0.87144400 pH/GHz L2 0.04338700 pH/GHz2

L3 -0.00064300 pH/GHz

MATCH [ F

Connector 2.92 mm CalKit ZV-Z229

Ser.Nr. 102350 StartFreq 0 Hz StoppFreq 40000000000 Hz

MATCH [ H I

Ser.Nr. 102427

THROUGH [ FF I

Ser.Nr. 102331

THROUGH [ MM I

Ser.Nr. 102404

DKD_PCI 1

(23 -1/+1 )C

501 1 .6559K02_1 01 035_i OD.MF

6/13

1.1 PhaseOPEN ( F ) Ser.Nr. 102384

-ooHDE &SCHWARZ 201 7-08

/GHz

Calculate Phase

/0

Phase Expanded Measured deviation to uncertainty of

Phase circuit Model measurement /0 /0 /0

0.05 -1.13 -1.16 -0.03 0.80

0.10 -2.26 -2.30 -0.05 0.80

0.25 -5.64 -5.73 -0.09 0.80

0.50 -11.28 -11.41 -0.12 0.80

0.75 -16.93 -17.07 -0.14 0.80

1.00 -22.58 -22.72 -0.15 0.80

2.00 -45.17 -45.40 -0.23 0.80

3.00 -67.80 -67.92 -0.13 0.80

4.00 -90.44 -90.54 -0.10 0.80

5.00 -113.10 —113.10 0.00 0.80

6.00 -135.77 -135.52 0.25 0.80

7.00 -158.45 -158.07 0.38 0.80

8.00 178.87 179.44 0.57 0.80

9.00 156.19 156.84 0.65 0.80

10.00 133.52 134.17 0.65 1.09

11.00 110.86 111.40 0.54 1.09

12.00 88.22 88.55 0.33 1.09

13.00 65.58 65.62 0.04 1.09

14.00 42.95 42.65 -0.29 1.09

15.00 20.32 19.72 -0.60 1.09

16.00 -2.31 -3.22 0.9l 1.09

17.00 -24.94 -26.01 -1.07 1.09

18.00 -47.58 -48.73 -1.15 1.09

19.00 -70.23 -71.32 -1.08 1.09

20.00 -92.90 -93.79 -0.89 1.09

21.00 -115.59 -116.04 -0.45 1.20

22.00 -138.29 -138.33 -0.04 1.20

23.00 -161.01 -160.59 0.42 1.20

24.00 176.25 177.12 0.88 1.20

25.00 153.49 154.75 1.26 1.20

26.00 130.71 132.25 1.54 1.20

27.00 107.91 109.50 1.59 1.20

28.00 85.09 86.59 1.50 1.20

29.00 62.25 63.43 1.18 1.20

30.00 39.39 40.18 0.79 1.20

31.00 16.49 16.79 0.29 1.20

32.00 -6.43 -6.55 -0.12 1.20

33.00 -29.40 29.87 -0.47 1.20

34.00 -52.40 -53.07 -0.66 1.20

35.00 -75.45 -76.03 -0.58 1.20

36.00 -98.55 -98.89 -0.34 1.20

37.00 -121.68 -121.64 0.05 1.20

38.00 -144.86 -144.13 0.73 1.20

39.00 -168.08 -166.72 1.36 1.20

40.00 168.67 170.64 1.98 1.20

501 1.6559K02_1 01 0351 OD.MF

7/13

1.2 Phase SHORT ( F ) Ser.Nr. 102423

Calculate Measured deviation to uncertainty of

Frequency Phase Phase circuit Model measurement /GHz

/0 /0 /0 /0

0.05 178.84 178.87 0.03 0.80

0.10 177.69 177.70 0.01 0.80

0.25 174.28 174.31 0.02 0.80

0.50 168.62 168.65 0.04 0.80

0.75 162.96 163.01 0.05 0.80

1.00 157.31 157.37 0.06 0.80

2.00 134.73 134.86 0.13 0.80

3.00 112.19 112.23 0.04 0.80

4.00 89.67 89.68 0.01 0.80

5.00 67.17 67.05 -0.13 0.80

6.00 44.69 44.38 -0.31 0.80

7.00 22.21 21.78 -0.43 0.80

8.00 -0.27 -0.83 -0.56 0.80

9.00 -22.75 -23.39 -0.65 0.80

10.00 -45.23 -45.85 -0.62 1.09

11.00 -67.72 -68.22 -0.49 1.09

12.00 -90.23 -90.48 -0.25 1.09

13.00 112.74 -112.65 0.09 1.09

14.00 -135.26 -134.80 0.45 1.09

15.00 -157.78 -157.04 0.74 1.09

16.00 179.69 -179.32 0.99 1.09

17.00 157.17 158.31 1.14 1.09

18.00 134.64 135.84 1.20 1.09

19.00 112.13 113.26 1.13 1.09

20.00 89.62 90.45 0.83 1.09

21.00 67.12 67.55 0.43 1.20

22.00 44.63 44.61 -0.02 1.20

23.00 22.15 21.62 -0.52 1.20

24.00 -0.33 -1.26 -0.93 1.20

25.00 -22.81 -24.04 -1.23 1.20

26.00 45.28 -46.71 -1.42 1.20

27.00 -67.75 -69.16 -1.41 1.20

28.00 -90.23 -91.50 -1.27 1.20

29.00 -112.69 -113.53 -0.83 1.20

30.00 -135.16 -135.54 -0.39 1.20

31.00 -157.62 -157.46 0.15 1.20

32.00 179.94 -179.40 0.66 1.20

33.00 157.51 158.56 1.05 1.20

34.00 135.10 136.45 1.35 1.20

35.00 112.71 114.04 1.33 1.20

36.00 90.35 91.41 1.06 1.20

37.00 68.01 68.65 0.63 1.20

38.00 45.71 45.48 -0.23 1.20

39.00 23.44 22.37 -1.06 1.20

40.00 1.19 -0.84 -2.03 1.20

DKD_PC1 I

501 l6559K02_l 01 035_l OD.MF

8/13

501 l.6559K02

DE &SCHWARZ

13 MATCH(F) SerNr 102350

Expanded Expanded uncertainty of Magnitude uncertainty of

Frequency Phase measurement Lin. measurement /GHz /0 /0 /1 /1

0.05 168.12 18000 0.0002 0.0050

0.10 96.18 180.00 0.0001 0.0050

0.25 35.00 180.00 0.0009 0.0050

0.50 29.91 180.00 0.0020 0.0050

0.75 30.87 180.00 0.0024 0.0050

1.00 28.05 180.00 0.0030 0.0050

2.00 6.46 180.00 0.0035 0.0050

3.00 -18.84 72.81 0.0052 0.0050

4.00 -45.07 180.00 0.0051 0.0065

5.00 -69.72 180.00 0.0050 0.0065

6.00 -76.85 180.00 0.0043 0.0065

7.00 -88.83 180.00 0.0030 0.0065

8.00 -68.99 180.00 • 0.0023 0.0065

9.00 -50.46 180.00 0.0038 0.0090

10.00 -54.09 180.00 0.0051 0.0090

11.00 -68.16 180.00 0.0065 0.0090

12.00 -81.45 180.00 0.0072 0.0090

13.00 -92.12 180.00 0.0066 0.0090

14.00 -98.65 180.00 0.0057 0.0090

15.00 -93.39 180.00 0.0049 0.0090

16.00 -75.81 180.00 0.0061 0.0090

17.00 -79.20 180.00 0.0082 0.0090

18.00 -93.83 52.79 0.0114 0.0090

19.00 -112.55 53.34 0.0139 0.0110

20.00 -136.49 45.97 0.0156 0.0110

21.00 -160.40 48.08 0.0150 0.0110

22.00 166.45 57.60 0.0132 0.0110

23.00 126.75 180.00 0.0109 0.0110

24.00 70.26 180.00 0.0097 0.0110

25.00 10.86 71.00 0.0117 0.0110

26.00 -35.39 43.83 0.0163 0.0110

26.50 -53.94 37.83 0.0185 0.0110

27.00 -69.68 33.02 0.0209 0.0110

28.00 -102.84 28.88 0.0238 0.0110

29.00 133.76 27.68 0.0249 0.0110

30.00 -165.97 27.87 0.0248 0.0110

31.00 158.02 32.27 0.0215 0.0110

32.00 113.90 39.67 0.0178 0.0110

33.00 59.58 44.35 0.0162 0.0110

34.00 5.00 39.10 0.0181 0.0110

35.00 —40.28 30.18 0.0231 0.0110

36.00 -77.09 25.70 0.0272 0.0110

37.00 -110.30 24.63 0.0284 0.0110

38.00 -140.50 24.45 0.0287 0.0110

39.00 -177.07 26.70 0.0263 0.0110

40.00 143.04 32.43 0.0217 0.0110

501 1.6559K02_101035_1OD.MF

9/13

14 PhaseOPEN(M) SerNr

Calculate Frequency Phase

/GHz /0

102284

Measured deviation to uncertainty of

Phase circuit Model measurement /0 /0 /0 i-oROHDE &SCHWARZ

0.05 -1.12 -L12 0.00 080

0.10 -2.25 -2.23 0.02 0.80 025 -5.62 -5.57 0.04 0.80

0.50 -11.24 -11.18 0.06 0.80

0.75 -16.86 -16.82 0.04 0.80

1.00 -22.49 -22.44 0.04 0.80

2.00 -4501 -45.07 -0.05 0.80

3.00 -67.58 -67.63 -0.05 0.80

4.00 -90.18 -90.27 -0.09 0.80

5.00 ll280 -112.98 -0.17 0.80

6.00 -135.45 -135.66 —0.21 0.80

7.00 -158.10 -158.37 -0.27 0.80

8.00 179.24 179.07 -0.17 0.80

9.00 156.58 156.41 -0.17 0.80

10.00 133.93 133.91 -0.02 1.09

11.00 111.29 111.48 0.19 1.09

12.00 88.66 88.98 0.32 1.09

13.00 66.04 66.56 0.52 1.09

14.00 43.44 44.11 0.67 1.09

15.00 20.84 21.60 0.76 1.09

16.00 -1.76 -1.03 0.73 1.09

17.00 -24.36 -23.78 0.58 1.09

18.00 -46.96 -46.56 0.40 1.09

19.00 -69.58 -69.42 0.16 1.09

20.00 -92.21 -92.27 -0.06 1.09

21.00 -114.86 -115.08 -0.21 1.20

22.00 -137.53 -137.82 -0.29 1.20

23.00 -160.23 -160.43 -0.20 1.20

24.00 177.05 177.07 0.01 1.20

25.00 154.31 154.50 0.19 1.20

26.00 131.54 132.16 0.62 1.20

27.00 108.74 109.82 1.08 1.20

28.00 85.90 87.36 1.46 1.20

29.00 63.03 84.88 1.85 1.20

30.00 40.12 42.16 2.05 1.20

31.00 17.16 19.25 2.10 1.20

32.00 -5.86 -3.92 1.94 1.20

33.00 -28.93 -27.17 1.77 1.20

34.00 -52.07 -50.58 1.49 1.20

35.00 -75.27 -74.06 1.22 1.20

36.00 -98.55 -97.53 1.02 1.20

37.00 -121.89 -120.84 1.06 1.20

38.00 -145.30 -144.03 1.27 1.20

39.00 -168.78 -167.00 1.77 1.20

40.00 167.69 170.11 2.42 1.20

501 1.6559K02_1 01 035_i OD.MF

10 I 13

I 5 Phase SHORT ( M ) Set Nt 102302

Calculate Measured Frequency Phase Phase

/GHz /0 /0

Phase deviation to circuit Model

Expanded uncertainty of measurement

201 7-08-09 L-ooHDE &SCHWARZ

0.05 178.84 178.85 0.01 0.80

0.10 177.69 177.71 0.01 0.80

0.25 174.28 174.28 0.00 0.80

0.50 168.61 168.63 0.02 0.80

0.75 162.95 162.97 0.02 0.80

1.00 157.30 157.32 0.02 0.80

2.00 134.71 134.81 0.09 0.80

3.00 112.17 112.26 0.09 0.80

4.00 89.67 89.80 0.13 0.80

5.00 67.19 67.46 0.28 0.80

6.00 44.72 45.01 0.29 0.80

7.00 22.27 22.63 0.36 0.80

8.00 -0.18 0.08 0.25 0.80

9.00 -22.62 -22.35 0.27 0.80

10.00 -45.07 -44.95 0.13 1.09

11.00 -67.53 -67.65 -0.11 1.09

12.00 -90.01 -90.30 —0.30 1.09

13.00 -112.49 -113.04 -0.55 1.09

14.00 -134.98 -135.76 -0.77 1.09

15.00 -157.49 -158.37 -0.88 1.09

16.00 180.00 179.15 —0.85 1.09

17.00 157.48 156.74 -0.74 1.09

18.00 134.96 134.47 -0.49 1.09

19.00 112.44 112.30 -0.14 1.09

20.00 89.92 90.15 0.23 1.09

21.00 67.40 67.93 0.52 1.20

22.00 44.89 45.64 0.75 1.20

23.00 22.37 23.24 0.87 1.20

24.00 -0.14 0.73 0.87 1.20

25.00 -22.66 -21.83 0.83 1.20

26.00 -45.18 -44.70 0.48 1.20

27.00 -67.70 -67.60 0.10 1.20

28.00 -90.22 -90.52 -0.30 1.20

29.00 -112.74 -113.39 -0.65 1.20

30.00 —135.26 -136.14 -0.89 1.20

31.00 -157.76 -158.67 —0.91 1.20

32.00 179.75 178.94 -0.81 1.20

33.00 157.28 156.63 -0.65 1.20

34.00 134.83 134.48 -0.34 1.20

35.00 112.41 112.34 -0.07 1.20

36.00 90.03 90.27 0.24 1.20

37.00 67.69 68.03 0.34 1.20

38.00 45.39 45.68 0.29 1.20

39.00 23.13 23.06 -0.07 1.20

40.00 0.93 0.29 -0.64 1.20

501 1 6559K021 01 035_i OD.MF

11 I 13

1.6 MATCH ( M ) Ser.Nr. 102427

Frequency Phase

/GHz /0

501 16559K02 foHDE &SCHWARZ

Magnitude Lb.

/1

/1

0.05 3.23 180.00 0.0022 0.0050

0.10 5.53 180.00 0.0024 0.0050

0.25 12.49 180.00 0.0032 0.0050

0.50 15.00 180.00 0.0040 0.0050

0.75 12.93 180.00 0.0043 0.0050

1.00 6.84 180.00 0.0046 0.0050

2.00 -20.27 180.00 0.0040 0.0050

3.00 -46.91 180.00 0.0032 0.0050

4.00 -93.20 180.00 0.0018 0.0065

5.00 152.47 180.00 0.0020 0.0065

6.00 106.62 180.00 0.0035 0.0065

7.00 81.96 180.00 0.0049 0.0065

8.00 43.77 180.00 0.0044 0.0065

9.00 31.99 180.00 0.0026 0.0090

10.00 176.13 180.00 0.0006 0.0090

11.00 165.11 180.00 0.0044 0.0090

12.00 141.99 180.00 0.0077 0.0090

C‘

13.00 120.51 63.94 0.0101 0.0090

14.00 100.07 54.97 0.0111 0.0090

15.00 79.91 58.54 0.0106 0.0090

16.00 59.62 180.00 0.0084 0.0090

17.00 52.18 180.00 0.0045 0.0090

18.00 110.88 180.00 0.0030 0.0090

19.00 127.65 180.00 0.0062 0.0110

20.00 111.37 180.00 0.0095 0.0110

21.00 90.22 180.00 0.0107 0.0110

22.00 67.23 180.00 0.0095 0.0110

23.00 35.63 180.00 0.0064 0.0110

24.00 -40.66 180.00 0.0026 0.0110

25.00 -136.50 180.00 0.0048 0.0110

26.00 -171.74 180.00 0.0092 0.0110

26.50 175.78 180.00 0.0101 0.0110

27.00 167.48 73.66 0.0115 0.0110

28.00 151.43 76.78 0.0114 0.0110

29.00 148.87 180.00 0.0099 0.0110

30.00 161.79 180.00 0.0094 0.0110

31.00 173.68 65.52 0.0122 0.0110

32.00 174.77 39.86 0.0178 0.0110

33.00 159.49 29.01 0.0239 0.0110

34.00 140.95 25.23 0.0275 0.0110

35.00 121.07 26.86 0.0259 0.0110

36.00 107.04 33.09 0.0212 0.0110

37.00 96.41 53.67 0.0140 0.0110

38.00 116.09 180.00 0.0080 0.0110

39.00 160.42 180.00 0.0103 00110

40.00 159.42 38.52 0.0185 0.0110

501 1.6559K02_1 01 035_i ODMF

12 I 13

501 i.6559K02 oHDE &SCHWARZ

1.7 THROUGH ( FF ) Ser.Nr. 102331

Reflection Expanded Transmission Expanded coefficient uncertainty of coefficient uncertainty of

Frequency Magnitude measurement Magnitude measurement /GHz /1 /1 /dE /dE

0.05 0.0006 0.0100 -0.003 0.021

0.10 0.0008 0.0100 -0.005 0.021

0.25 0.0015 0.0100 -0.007 0.021

0.50 0.0025 0.0100 -0.010 0.021

0.75 0.0031 0.0100 -0.012 0.021

1.00 0.0039 0.0100 -0.015 0.021

2.00 0.0046 0.0100 -0.021 0.021

3.00 0.0061 0.0100 -0.026 0.021

4.00 0.0059 0.0130 -0.031 0.021

5.00 0.0050 0.0130 -0.035 0.021

6.00 0.0024 0.0130 -0.039 0.021

7.00 0.0009 0.0130 -0.043 0.021

8.00 0.0049 0.0130 -0.042 0.021

9.00 0.0078 0.0180 -0.051 0.021

10.00 0.0109 0.0180 -0.054 0.031

11.00 0.0138 0.0180 -0.057 0.031

12.00 0.0151 0.0180 -0.061 0.031

13.00 0.0131 0.0180 -0.065 0.031

14.00 0.0112 0.0180 -0.066 0.031

15.00 0.0085 0.0180 -0.070 0.031

16.00 0.0040 0.0180 -0.074 0.031

17.00 0.0012 0.0180 -0.076 0.031

18.00 0.0043 0.0180 -0.078 0.031

19.00 0.0067 0.0220 -0.080 0.060

20.00 0.0084 0.0220 —0.080 0.060

21.00 0.0084 0.0220 -0.082 0.060

22.00 0.0105 0.0220 -0.085 0.060

23.00 0.0118 0.0220 -0.085 0.070

24.00 0.0123 0.0220 -0.087 0.070

25.00 0.0149 0.0220 -0.089 0.070

26.00 0.0175 0.0220 -0.092 0.070

27.00 0.0192 0.0220 -0.095 0.100

28.00 0.0174 0.0220 -0.094 0.100

29.00 0.0144 0.0220 -0.094 0.100

30.00 0.0094 0.0220 -0.096 0.100

31.00 0.0037 0.0220 -0.097 0.120

32.00 0.0072 0.0220 -0.097 0.120

33.00 0.0156 0.0220 -0.104 0.120

34.00 0.0240 0.0220 -0.108 0.120

35.00 0.0288 0.0220 -0.112 0.120

36.00 0.0301 0.0220 -0.117 0.120

37.00 0.0259 0.0220 -0.117 0.120

38.00 0.0202 0.0220 -0.120 0.120

39.00 0.0119 0.0220 -0.121 0.120

40.00 0.0035 0.0220 -0.125 0.120

0 1.8 THROUGH(FF)

THROUGH [ FF I

Ser.Nr. 102331

0.018 dB/sqrt(GHz)

25.579 mm

Length

DKD_PC1 I

501 l.6559K02_101035j0D.MF

13/13

I JO THROUGH(MM)

THROUGH [ MM I

Ser . Nr.

2 Filename on Data storage

I 9 THROUGH ( MM ) Set Nt 102404

Reflection Expanded Transmission Expanded coefficient uncertainty of coefficient uncertainty of

Frequency Magnitude measurement Magnitude measurement /GHz /1 /1 /do /dB

0.05 0.0008 0.0100 -0.004 0.021

0.10 0.0012 0.0100 -0.004 0.021

0.25 0.0022 0.0100 -0.008 0.021

0.50 0.0035 0.0100 -0.011 0.021

0.75 0.0045 0.0100 -0.014 0.021

1.00 0.0051 0.0100 -0.016 0.021

2.00 0.0057 0.0100 -0.021 0.021

3.00 0.0064 0.0100 -0.026 0.021

4.00 0.0042 0.0130 -0.031 0.021

5.00 0.0005 0.0130 -0.035 0.021

6.00 0.0024 0.0130 -0.038 0.021

7.00 0.0047 0.0130 -0.041 0.021

8.00 0.0054 0.0130 -0.044 0.021

9.00 0.0039 0.0180 -0.047 0.021

10.00 0.0015 0.0180 -0.050 0.031

11.00 0.0004 0.0180 -0.054 0.031

12.00 0.0008 0.0180 -0.057 0.031

13.00 0.0028 0.0180 -0.058 0.031

14.00 0.0071 0.0180 -0.062 0.031

15.00 0.0121 0.0180 —0.064 0.031

16.00 0.0155 0.0180 -0.065 0.031

17.00 0.0171 0.0180 -0.068 0.031

18.00 0.0157 0.0180 -0.070 0.031

19.00 0.0108 0.0220 -0.073 0.060

20.00 0.0033 0.0220 -0.076 0.060

21.00 0.0050 0.0220 -0.077 0.060

22.00 0.0132 0.0220 -0.081 0.060

23.00 0.0181 0.0220 -0.086 0.070

24.00 0.0198 0.0220 -0.087 0.070

25.00 0.0189 0.0220 -0.089 0.070

26.00 0.0140 0.0220 -0.092 0.070

27.00 0.0083 0.0220 -0.093 0.100

28.00 0.0041 0.0220 -0.099 0.100

29.00 0.0029 0.0220 -0.101 0.100

30.00 0.0060 0.0220 -0.104 0.100

31.00 0.0094 0.0220 -0.107 0.120

32.00 0.0134 0.0220 -0.114 0.120

33.00 0.0190 0.0220 -0.115 0.120

34.00 0.0220 0.0220 -0.117 0.120

35.00 0.0199 0.0220 -0.120 0.120

36.00 0.0138 0.0220 -0.121 0.120

37.00 0.0108 0.0220 -0.121 0.120

38.00 0.0185 0.0220 -0.124 0.120

39.00 0.0265 0.0220 -0.126 0.120

40.00 0.0282 0.0220 -0.123 0.120

102404

Length

0.018 dB/sqrt(GHz)

25.572 mm

2 1 File description

ZVZ229.ca1kit - characteristic data of the calibration kit recommended for use with R&S ZVA, R&S ZVB, R&S ZVT, R&S ZNB

ZV-Z229.ck - polynom data of the calibration kit recommended for use with R&S ZVR, R&S ZVC, R&S ZVM, R&S ZVK p (p C -) = C

CD .

: C-

CD = C

CD CD C

Cl

I f

N

PF

.4

,0

V

.O

C = J J

D

C C

HDE &SCHWARZ

Calibration Certificate Certificate Number 12-100030139432 Kali b riersche I n Zertifikatsnummer

This calibration certificate documents,Unit Data that the named item is tested and

Item Torque Wrench measured against defined specifications.

Gegenstand

Measurement results are located usually

Manufacturer Rohde & Schwarz in the corresponding interval with a

Hersteller probability of approx. 95% (coverage factor k 2). Calibration is performed with Type R&S®ZNZTW test equipment and standards directly orTyp indirectly traceable by means of approved

Material Number I 328.8534.35 Serial Number I 02066 calibration techniques to the PTBIDKD or Materialnummer Seriennummer other national I international standards, which realize the physical units ofAsset Number measurement according to the InternationalInventarnummer

System of Units (SI). In all cases where no standards are available, measurements are referenced to standards of the R&SOrder Data laboratories. Principles and methods of

Customer calibration correspond and are conformant Auftraggeber with EN lSO!IEC 17025. The applied quality system is certified to EN ISO 9001.

This calibration certificate may not be reproduced other than in full. Calibration certificates without signatures are not valid. The user is obliged to have the object recalibrated at appropriate intervals.

Order Number Dieser Kalibnerschein dokumentiert, dass Bestelinummer der genannte Gegenstand nach festgelegten

Vorgaben gepruft und gemessen wurde.

Date of Receipt

Die Messwerte lagen rn Regelfall mit einerEingangsdatum Wahrscheinhichkeit von annähemd 95% rn

Pe rio rmanc e zugeordneten Werteintervall (Erweiterte

Messunsicherheit mit k = 2). Die Kalibrierung Place and Date of Calibration Teisnach, 20 17-08-02 erfolgte mit Messrnitteln und Normalen, dieOrt und Daturn der Kalibrierung direkt oder indirekt durch Ableitung rnittels

Scope of Calibration Standard Calibration anerkannter Kalibriertechniken rückgeführt Umfang der Kalibrierung sind auf Normale der PTB/DKD oder anderer

New device nationaler/ internationaler Standards zurStatem ent of Compliance Darstellung der physikalischen Einheiten in(Incoming)

KonformitStsaussage Obereinstirnrnung mit dern Internationalen (Anhieferung) Einheitensystern (SI). Wenn keine Normale existieren, erfolgt die Rückführung auf

Bezugsnorrnale der R&S-Laboratorien.

Statement of Compliance *) All measured values are within Grundsatze und Verfahren der Kalibrierung

(Outgoing) the data sheet specifications beziehen sich auf und entsprechen EN ISO/IEC Konforrnitatsaussage I 7025. Das angewandte Qualitätsrnanagernent (Auslieferung)

Systern ist zertifiziert nach EN ISO 9001.

Extend of Calibration Documents 2 Pages Calibration Certificate md. Outgoing Dieser Kalibrierschein dart nur vollstSndig Urnfang des Kalibrierdokurnents Resu Its und unverSndert weiterverbreitet werden.

Kalibrierscheine ohne Unterschriften sind ungOltig. Für die Einhaltung einer angernes senen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich.

Rohde & Schwarz GmbH & Co. KG; Teisnach

Date of Issue Head of Laboratory Person Responsible Ausstellungsdatum Laborleitung Bearbeiter gwi 2017-08-02 er ard Kokott Andreas Stettmer

Page (Seite) 112

Vers2Ol 0-05-05

Rohde & Schwarz GrnbH & Co. KG I Geschäftsführung / Executive Board: Christian Leicher (Vorsitzender / Chairrnan), Peter Riedel I Sitz der Gesellschaft / Company’s Place of Business:

München Registereintrag / Cornrnercial Register No.: HRA 16270 I Persönlich haftender Gesellschafter / Personally Liable Partner: RUSEG Verwaltungs-GrnbH I Sits der Gesellschaft /

Cornpanys Place of Business: München I Registereintrag I Cornrnercial Register No.: HRB 7534 I Deutsche Bank AG — IBAN DE82 7007 0010 0203 1466 00 — BIC DEUTDEMM I Sparkasse Regen-Viechtach — IBAN DE2O 7415 1450 0240 3005 25 — BIC BYLADEM1REG I Urnsatzsteuer-ldentifikationsnurnrner (USt-ldNr.) I VAT Identification No.: DE 130 256 683 I

Elektro-Altgeräte Register (EAR) / WEEE Register No.: DE 240 437 86 Template PAD-T-M: 3573.7850.04/02.00/RL/1/DEEN Page 112

Material Number 1328.8534.35 Serial Number 102066

Explanation:

DLL

DUL

Datasheet Lower Limit

Datasheet Upper Limit

Certificate N umber I 2-100030139432

Caiibration Method Manufacturer Documentation - R&S PB 1328.8534.01 Kalibrieranweisung

Ambient Temperature (23 ) °C Relative Humidity 20 % to 90 ¾ Umgeb ungstem peratur Relative Lufffeuchte

Working standards used (having a significant effect on the accuracy)

Verwendete Gebrauchsnormale (mit signifikantem Einfluss auf die Genauigkeit) item Type Serial Number Calibration Certificate Number Cal. Due

Gegenstand Typ Seciennummer Kalibrierscheinnummec Kalibr. bis

Torque Screwdriver Tester TST 2 95262 P-5226264 2019.070.04 to 2 Nm

UGBI A compliance statement may be possible where a confidence level of less than 95 % is acceptable.

Die Bestätigung der Konformität st mdglich, sofern em Grad des Vertrauens von weniger ala 95 % akzeptabel st.

UGB2 A non-compliance statement may be possible where a confidence level of less than 95 % is acceptable.

Die Bestätigung der Nicht-Konformität st möglich, sofern em Grad des Vertrauens von weniger als 95 % akzeptabel st.

(*) Ref : ILAC-G8:2009 Guidelines on Assessment and Reporting of Compliance with Specification (based on measurements and tests in a laboratory)’

Notes

Anmerkungen

Incoming Results

Measurement numbers I 2 3 4 5 DLL DUL Evaluation Reading values (Nm)

Nominal value fNm)

Average value (Nm)

Expanded uncertainty (Nm)

Torque repeatability (Nm)

Outgoing Results

Measurement numbers I 2 3 4 5 DLL DUL Evaluation Reading values fNm) 0.904 0.901 0.902 0.908 0.906 N/A N/A N/A Nominal value (Nm) 0.900 N/A N/A N/A Average value (N.m) 0.904

0.800 1.000 PASSExpanded uncertainty (N.m) 0.006

Torque repeatability (Nm) 0.007 0 0.054 PASS

€ptu E’[) If! /./%O fl4/t i/l’Lj ‘U image2.emf

LABORATORY /OFFICE:

54043 County Ad. 37 Nunn, CO 80648 Phone:970·897·27tt

FAX: 970·897·2710

COLORADO ENGINEERING

EXPERIMENT STATION INC.

•.. the primary source for now meusurement solutions ...

CERT/FICA TE OF CAL/BRA TION

Traceable to the

NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY

Customer: US Army TARDEC Item Calibrated: Vortex Address: 6501E11 Mile Rd

\Varren,MI48397-5000 Serial Number: 95221444

Date: 19 December 2017 Order: cc Job Number: CE27650

CEESI Data File(s): 17USA T-0002_1 Report Number:

The uncertainty in the tlowrate indicated by CEESI standards is contained in this report under Statemelll of Uncertainties.

The calibration(s) identified by the above CEESI DATA FILE (S) were performed using standards that are traceable to the National Institute of Standards and Technology. The calibration(s) were performed in accordance with any or all of the following: The current revision of CEESI PROCEDURE NO. IO ; NIST Handbook 150 (NVLAP accreditation under NVLAP lab code 200377-0); ISO/IEC 17025:2005;

ANSl/NCSL Z540-1-1994; and Former MIL-STD-45662A. The stated uncertainties were calculated in accordance with the current revision of CEESI Report "Calibration Services Uncertainty Analyses".

Calibration Method [ ] Primary [ X ] Secondary

This calibration is: [ X] As Found [ X] As Left

NOTES:

1. Re-calibration intervals should be determined by the user and based on meter type, conditions of use, and the degree of risk associaled with the measurement. Please contact CEESI for guidance in establishing adequate re calibration intervals.

2. This Certificate and accompanying documentation shall not be reproduced, except in full, without the written consenl of Colorado Engineering Experiment Station Inc. The signing of the document docs not claim or imply product certification, approval, or endorsement by NVLAP, NIST, CEESI, or any agency of the federal government.

CEESI Form 140 8·8·06

PSL00499

michael.r.trombley

Sticky Note

Could not perform an as-found based on previous calibration due to fact the way previous calibration was performed with different values.

,e€Es1owa

LABORATORV/OFACE:

54043 County Rd. 37 NUM, Colo. 80648 Phone: 970-897-2711 FAX: 97o-897-2710

... the primary source for flow measurement solutions ...

Serial Number: 95221444 Order: CC

Calibration of a Vortex Model: VF61 SOO-NNNNNN For: US Army TARDEC Data File: 17USAT-0002_ 1 Job: CE27650 Date: 19 December 2017 Inlet Diameter: 6 inches Test gas: AIR Standard density= 0.074896 lbm/ft3 at standard conditions of 529.67 °Rt and 14.696 Psia Freq: Meter Output, Hertz (pulses/sec) ACFM: Volumetric flowrate at meter BODY, actual cubic feet per minute KFactor: Pulses per cubic foot ReyNo: Pipe Reynolds number Density: Flowing density at meter BODY, pounds mass per cubic foot

Pt. Freq ACFM KFactor ReyNo Density

1 44.30 272.74 9.745 79179 0.0841 2 250.98 1519.45 9.911 443041 0.0843 3 228.95 1392.66 9.864 407267 0.0845 4 229.16 1392.02 9.877 407607 0.0846 5 208.58 1274.69 9.818 373842 0.0846 6 188.42 1154.26 9.794 338680 0.0847 7 188.58 1153.89 9.806 338557 0.0846 8 168.74 1032.48 9.806 302725 0.0846 9 149.05 910.00 9.828 266596 0.0846 10 148.92 910.01 9.818 266529 0.0845 11 126.85 778.45 9.777 227907 0.0845 12 105.75 655.78 9.676 191831 0.0845 13 105.90 655.57 9.692 191770 0.0845 14 85.40 531.06 9.649 155112 0.0844 15 66.39 408.97 9.740 119350 0.0844 16 66.42 409.53 9.731 119697 0.0845 17 24.54 149.75 9.832 43687 0.0844 18 24.19 149.74 9.69 43672 0.0843

IOWA HIGH FLOW FACILITY

2365 24oth Sl Gamer, IA 50438 Phone: 641-923-3664

FAX: 641-923-3893

LABORATORY/OFFICE:

54043 County Rd. 37 Nunn, Colo. 80648 Phone:970-897-2711

FAX: 970-897-2710

..• the primary source for flow mcasurcmcnt solutions ...

STATEMENT OF UNCERTAINTIES

Serial Number: 95221444 Order: CC

,eEESiowa J<Nt/A HIGH FLOW FACILITY 2365 240th Sl Garner, IA 50438 Phone:641-923.a664

FAX: 841-923-3693

Calibration of a Vortex Model: VF61 SOO-NNNNNN For: US Army TARDEC Data File: 17USAT-0002_ 1 Job: CE27650 Date: 19 December 2017

Freq: Uncertainty in Frequency at a 95% confidence(%) ACFM: Uncertainty in Volume Flowrate at a 95% confidence(%) KFactor: - ReyNo: Uncertainty in Reynolds Number at a 95% confidence(%) Density: Uncertainty in Density at a 95% confidence(%)

Pt. Freq ACFM KFactor ReyNo Density

1 0.013 0.31 2.0 0.11 2 0.011 0.34 2.0 0.11 3 0.011 0.33 2.0 0.11 4 0.010 0.33 2.0 0.11 5 0.012 0.33 2.0 0.11 6 0.013 0.33 2.0 0.11 7 0.011 0.33 2.0 0.11 8 0.013 0.33 2.0 0.11 9 0.011 0.33 2.0 0.11 10 0.010 0.33 2.0 0.11 11 0.012 0.32 2.0 0.11 12 0.014 0.32 2.0 0.11 13 0.013 0.32 2.0 0.11 14 0.012 0.32 2.0 0.11 15 0.012 0.31 2.0 0.11 16 0.012 0.31 2.0 0.11 17 0.031 0.31 2.0 0.11 18 0.059 0.31 2.0 0.11

Page 3 of4

LABORATORY OFFICE

)40.l 3 COllll!y Rd. 37 1\\11111, Colo. ~8 Pllooc: 970-897-271 l FA.X: 970.897-mo

Calibration Checklist Chc<lli11 II>: J.uJ l!Al'C"l:

Job#: CE276SO

COLORADOE~GTh~ERING

EXPERL\IE~T STATION ~C.

•.. rbe prinwr source fa" flow ~1uranenr solUllOllS .•.

Data File#: l ?USAT-0002

Customer Name: US Anny TARDEC Purchase Order: cc Serial#: 95221~ Model#:

Part#: Tag#:

Meter Type: VORTEX Description:

Cal. Conditions: Inlet Pressure, Inlet Tcmpcr:itun:

Data Acquisition: CEESI08 l

List of Instruments Used:

QfC Number lnatrument De1cripllon

1552 DAO

60174 Mensor6010

60362 Mensor6010

List of Standards Used:

Standard(•I Number

CFV312.

CFV15

Cal. Due Date

08!0312018

Ot/0512018

01/09/2018

Quality Control Supervisor; Mark Schulz on 1211912017

VF61SOO-NNNNNN

~owa IOWA HIGH FLO\\' FACll.ITY :!365…