Attachment_0002_to_RFI_(Female_Shower_and_rest_room_container).docx

DOCX document 16 KB Posted

Attached to
Male & Female Shower/Restroom Containers
Solicitation number
W52P1J-18-T-Shower_Restroom_Container
Issued by

About this file

Specifications for female shower and restroom container

View the file

Other files

File Type Posted
Attachment_0001_to_RFI_(Male_shower_and_rest_room_contrainer).docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Purchase one(1) 9’6”H x 8’0”W x 40'0”L Women's, non-self-contained, ground level, climate controlled, running water changing room with all amenities, complete with full height stalls, toilets, lavatories, showers, HVAC, Diamond Pattern 2.5 Vinyl or Spray-on non-skid floor surface, and dual locking access doors.

Turnkey item should be delivered ready to deploy onto construction/industrial site.

The changing room must be of "Modified Shipping Container" type.

The changing room must be COMMERCIAL/INDUSTRIAL quality.

The changing room must have ability to be moved multiple times to meet manpower requirements.

The changing room must have ability to be tied into existing water and sewer lines.

The changing room must have ability to be tied into existing electrical service.

Changing rooms to Include (Drawing Attached):

Women's Room:

3 Showers - 32"X32" One Piece Fiberglass W/Curtain & P.B Mix Valve 3 Towel Hangers 3 Toilets with T.P Dispensers and Partitions (5'H Steel Head Rail Braced W/Door & Lock, Mount 12" AFF Stalls) 4 Sinks W/Faucets 4 Mirrors - 24"X36" W/Stainless Steel Frame 2 Paper Towel Dispensers 2 Soap Dispensers

Remove Container End Doors and Replace with Welded Corrugated Metal, match gage and style to Container Body OR Permanently seal and weld doors shut.

Exterior Coatings:

Surface Prep: Sand Blast Paint: Envirolastic 840 DTM Color: Desert Tan (body of container and doors)

Floors:

Insulation - R-10 Rigid Foam board Joist - 2x6 #2 SPF or better@16” O/C /Shower Are Raised Floor Decking – 3/4” Underlayment Covering – Black or Gray Diamond Pattern 2.5 Vinyl or Spray-on non-skid floor surface

Walls:

Exterior Studs – 2x4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6” Insulation - R-11 KRAFT FACED FIBERGLASS BATT TYPE Interior Studs - 2X4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6” Chase Walls - 2X4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6” Covering -.030" FRP (Fiber Reinforced Plastic) BONDED TO 3/8" OSB

Interior Trim:

Floor Base - 6" VINYL COVEBASE Floor Base Color – BLACK Ceiling Cove - FRP PROFILES Inside Corner - FRP PROFILES Wall Panel Seams - FRP PROFILES Door Trim - FRP PROFILES Wall Color – OFF WHITE

Roof:

Roof Framing – 2x4 @ 16" O/C Insulation – R-21 16” UNFACED FIBERGLASS BATT TYPE Ceiling System - .030" FRP BONDED TO 3/8" OSB Ceiling Height - 7’-6"

Exterior Doors:

2ea – 36” x 80” Steel Door/Steel Jamb Hardware - Keyed Lever Set Grade 2 Hardware - Closer- Standard Grade 2 ADA Approved Hardware – Steel Drip Cap Hardware - Welded Tube Steel Frame to Container Hardware - Metal Threshold with Seal Finish - Painted

Interior Door:

1ea – 36”X80” Prefinished Wood Hollow Core Frame – Prefinished Wood Jamb Hardware – 1 Passage Lever Set (Grade 3) Hardware – Non-Mortise Hinges

Electrical:

Service – 120/208V, 3 Wire, 60Hz Main Panel – 24 Space, NEMA 3R, EXTERIOR, 200 Amp Disconnect 120/208V 60Hz (Single or 3 Phase acceptable; remain consistent with HVAC) Service Entrance – 2” EMT through REAR wall Wiring System - MIN. #14 AWG (90 DEG. C COPPER WIRE) W/GROUND - ROMEX Receptacles – INTERIOR - 6ea GFCI PROTECTED DUPLEX GROUNDING TYPE, 125V, 15 AMP EXTERIOR - 1ea GFCI PROTECTED DUPLEX GRND'G, 125V, 20 AMP WEATHERPROOF Switches – Single – 6ea 120V 15 AMP TOGGLE TYPE

Lighting:

Ceiling Lights – 6ea 4', 2-TUBE, FLUORESCENT, SURFACE MOUNT / VAPOR PROOF COVERS OR EQUIVILENT LED FIXTURES Emergency Lights – 2ea DUAL HD EXIT/EMERGENCY LIGHT W/BATTERY PACK – UNSWITCHED Exterior Lighting - 2ea Weatherproof Exterior Lighting (1 @ each door)

Plumbing:

Water Lines –PEX Plastic Supply, through REAR wall Shut Off Valves – All Fixtures Waste Lines - SCH 40 PVC Plastic, through REAR wall Water Closet – 3ea WHITE STANDARD BOWL TANK TYPE / REAR DISCHARGE Lavatories – 4ea 19X17 WALL HUNG W/ UPGRADE FAUCET Showers – 3ea 32X32 ONE PIECE FIBERGLASS W/CURTAIN & P.B. MIX VALVE Water Heaters – 2ea 80 GAL. COMMERCIAL ELEC. WTR. HTR. DOUBLE ELEMENT 208V Drains – 1ea 3" PVC FLOOR DRAIN W/TRAP PRIMER

Modular Partitions-Toilet Fixtures - 5'H STEEL HEAD RAIL BRACED W/DOOR & LOCK, MOUNT 12" AFF T.P. Holders – SINGLE ROLL TOILET PAPER DISPENSERS Mirrors – 4ea 24X36 WITH STAINLESS STEEL FRAME

HVAC Unit – Heating (Minimum Requirement) - 1ea 2-1/2 TON 208V A/C W/15KW HT Thermostat – 1ea Wall Mounted Programmable with Tamper Resistant Cover Supply Air Duct - INSTALLED OVERHEAD Supply Air Diffuser – 5ea 10”X10” W/ADJUSTABLE DAMPER IN CEILING Return Air Diffuser – 24”X14” Wall Grill Exhaust/Vent Fans - 4ea Fresh Air Damper – 1ea

Furniture:

Lockers - 8ea 12"X18"X78" Two-Tier Locker w/6" legs Benches - 1ea 12’X9 1/2'X"X18"High Wood Benches