Attachment_0001_(Salient_Characteristics)_to_Combined_Synopsis_&_Solicitation_on_containers_for_MCAAP.xlsx
XLSX spreadsheet 16 KB Posted
- Attached to
- Male & Female Shower/Restroom Containers
- Solicitation number
- W52P1J-18-T-Shower_Restroom_Container
About this file
Containers Salient Characteristics
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Requirement Salient Characteristics | Vendors ability to meet the specification:(yes/no) | Vendors Characteristics in Detail |
| Male shower, restroom & changing room container | ||
| The changing room must be of "Modified Shipping Container" type. | ||
| The changing room must be COMMERCIAL/INDUSTRIAL quality | ||
| The changing room must have ability to be moved multiple times to meet manpower requirements. | ||
| The changing room must have ability to be tied into existing water and sewer lines | ||
| The changing room must have ability to be tied into existing electrical service. | ||
| 3 Showers -32"X32" One Piece Fiberglass W/Curtain & P.B Mix Valve | ||
| 3 Towel Hangers | ||
| 3 Toilets with T.P Dispensers and Partitions (5'H Steel Head Rail Braced W/Door & Lock, Mount 12" AFF Stalls) | ||
| 4 Sinks W/Faucets | ||
| 4 Mirrors - 24"X36" W/Stainless Steel Frame | ||
| 2 Paper Towel Dispensers | ||
| 2 Soap Dispensers | ||
| 1 Wall Hung Urinal | ||
| Remove Container End Doors and Replace with Welded Corrugated Metal, match gage and style to Container Body OR Permanently seal and weld doors shut. | ||
| Exterior Coatings: | ||
| Surface Prep: Sand Blast | ||
| Paint: Envirolastic 840 DTM | ||
| Color: Desert Tan (body of container and doors) | ||
| Floors: | ||
| Insulation - R-10 Rigid Foam board | ||
| Joist - 2x6 #2 SPF or better@16” O/C /Shower Are Raised Floor | ||
| Decking – 3/4” Underlayment | ||
| Covering – Black or Gray Diamond Pattern 2.5 Vinyl or Spray-on non-skid floor surface | ||
| Walls: | ||
| Exterior Studs – 2x4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6” | ||
| Insulation - R-11 KRAFT FACED FIBERGLASS BATT TYPE | ||
| Interior Studs - 2X4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6” | ||
| Chase Walls - 2X4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6” | ||
| Covering -.030" FRP (Fiber Reinforced Plastic) BONDED TO 3/8" OSB | ||
| Interior Trim: | ||
| Floor Base - 6" VINYL COVEBASE | ||
| Floor Base Color – BLACK | ||
| Ceiling Cove - FRP PROFILES | ||
| Inside Corner - FRP PROFILES | ||
| Wall Panel Seams - FRP PROFILES | ||
| Door Trim - FRP PROFILES | ||
| Wall Color – OFF WHITE | ||
| Roof: | ||
| Roof Framing – 2x4 @ 16" O/C | ||
| Insulation – R-21 16” UNFACED FIBERGLASS BATT TYPE | ||
| Ceiling System - .030" FRP BONDED TO 3/8" OSB | ||
| Ceiling Height - 7’-6" | ||
| Exterior Doors: | ||
| 2ea – 36” x 80” Steel Door/Steel Jamb | ||
| Hardware - Keyed Lever Set Grade 2 | ||
| Hardware - Closer- Standard Grade 2 ADA Approved | ||
| Hardware – Steel Drip Cap | ||
| Hardware - Welded Tube Steel Frame to Container | ||
| Hardware - Metal Threshold with Seal | ||
| Finish - Painted | ||
| Interior Door: | ||
| 1ea – 36”X80” Prefinished Wood Hollow Core | ||
| Frame – Prefinished Wood Jamb | ||
| Hardware – 1 Passage Lever Set (Grade 3) | ||
| Hardware – Non-Mortise Hinges | ||
| Electrical: | ||
| Service – 120/208V, 3 Wire, 60Hz | ||
| Main Panel – 24 Space, NEMA 3R, EXTERIOR, 200 Amp Disconnect 120/208V 60Hz (Single or 3 Phase acceptable; remain consistent with HVAC) | ||
| Service Entrance – 2” EMT through REAR wall | ||
| Wiring System - MIN. #14 AWG (90 DEG. C COPPER WIRE) W/GROUND - ROMEX | ||
| Receptacles – | ||
| INTERIOR - 6ea GFCI PROTECTED DUPLEX GROUNDING TYPE, 125V, 15 AMP | ||
| EXTERIOR - 1ea GFCI PROTECTED DUPLEX GRND'G, 125V, 20 AMP WEATHERPROOF | ||
| Switches – | ||
| Single – 6ea 120V 15 AMP TOGGLE TYPE | ||
| Lighting: | ||
| Ceiling Lights – 6ea 4', 2-TUBE, FLUORESCENT, SURFACE MOUNT / VAPOR PROOF COVERS OR EQUIVILENT LED FIXTURES | ||
| Emergency Lights – 2ea DUAL HD EXIT/EMERGENCY LIGHT W/BATTERY PACK – UNSWITCHED | ||
| Exterior Lighting - 2ea Weatherproof Exterior Lighting (1 @ each door) | ||
| Plumbing: | ||
| Water Lines –PEX Plastic Supply, through REAR wall | ||
| Shut Off Valves – All Fixtures | ||
| Waste Lines - SCH 40 PVC Plastic, through REAR wall | ||
| Water Closet – 3ea WHITE STANDARD BOWL TANK TYPE / REAR DISCHARGE | ||
| Urinal – 1ea WHITE WALL HUNG W/INTEGRAL TRAP & FLUSH VALVE | ||
| Lavatories – 4ea 19X17 WALL HUNG W/ UPGRADE FAUCET | ||
| Showers – 3ea 32X32 ONE PIECE FIBERGLASS W/CURTAIN & P.B. MIX VALVE | ||
| Water Heaters – 2ea 80 GAL. COMMERCIAL ELEC. WTR. HTR. DOUBLE ELEMENT 208V | ||
| Drains – 1ea 3" PVC FLOOR DRAIN W/TRAP PRIMER | ||
| Modular Partitions-Toilet Fixtures - 5'H STEEL HEAD RAIL BRACED W/DOOR & LOCK, MOUNT 12" AFF | ||
| T.P. Holders – SINGLE ROLL TOILET PAPER DISPENSERS | ||
| Mirrors – 4ea 24X36 WITH STAINLESS STEEL FRAME | ||
| HVAC Unit – | ||
| Heating (Minimum Requirement) - 1ea 2-1/2 TON 208V A/C W/15KW HT | ||
| Thermostat – 1ea Wall Mounted Programmable with Tamper Resistant Cover | ||
| Supply Air Duct - INSTALLED OVERHEAD | ||
| Supply Air Diffuser – 5ea 10”X10” W/ADJUSTABLE DAMPER IN CEILING | ||
| Return Air Diffuser – 24”X14” Wall Grill | ||
| Exhaust/Vent Fans - 4ea | ||
| Fresh Air Damper – 1ea | ||
| Furniture: | ||
| Lockers - 8ea 12"X18"X78" Two-Tier Locker w/6" legs | ||
| Benches - 1ea 12’X9 1/2'X"X18"High Wood Benches | ||
| Mobility: | ||
| Containers will not have wheels | ||
| Containers must be capable of material handling (movement) by forklift, flatbed trailer, and Rough Terrain Container Handler (RTCH) | ||
| American with Disability Act (ADA) Certified | ||
| (1) 9’6”H x 8’0”W x 40'0”L Men's, non-self-contained, ground level, climate controlled, running water changing room with all amenities, complete with full height stalls, toilets, urinal, lavatories, showers, HVAC, Diamond Pattern 2.5 Vinyl or Spray-on non-skid floor surface, and dual locking access doors. Turnkey item should be delivered ready to deploy onto construction/industrial site. | ||
| Female shower, restroom & changing room container | ||
| The changing room must be of "Modified Shipping Container" type. | ||
| The changing room must be COMMERCIAL/INDUSTRIAL quality. | ||
| The changing room must have ability to be moved multiple times to meet manpower requirements. | ||
| The changing room must have ability to be tied into existing water and sewer lines. | ||
| The changing room must have ability to be tied into existing electrical service. | ||
| Women's Room: | ||
| 3 Showers - 32"X32" One Piece Fiberglass W/Curtain & P.B Mix Valve | ||
| 3 Towel Hangers | ||
| 4 Toilets with T.P Dispensers and Partitions (5'H Steel Head Rail Braced W/Door & Lock, Mount 12" AFF Stalls) | ||
| 4 Sinks W/Faucets | ||
| 4 Mirrors - 24"X36" W/Stainless Steel Frame | ||
| 2 Paper Towel Dispensers | ||
| 2 Soap Dispensers | ||
| Remove Container End Doors and Replace with Welded Corrugated Metal, match gage and style to Container Body OR Permanently seal and weld doors shut. | ||
| Exterior Coatings: | ||
| Surface Prep: Sand Blast | ||
| Paint: Envirolastic 840 DTM | ||
| Color: Desert Tan (body of container and doors) | ||
| Floors: | ||
| Insulation - R-10 Rigid Foam board | ||
| Joist - 2x6 #2 SPF or better@16” O/C /Shower Are Raised Floor | ||
| Decking – 3/4” Underlayment | ||
| Covering – Black or Gray Diamond Pattern 2.5 Vinyl or Spray-on non-skid floor surface | ||
| Walls: | ||
| Exterior Studs – 2x4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6” | ||
| Insulation - R-11 KRAFT FACED FIBERGLASS BATT TYPE | ||
| Interior Studs - 2X4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6” | ||
| Chase Walls - 2X4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6” | ||
| Covering -.030" FRP (Fiber Reinforced Plastic) BONDED TO 3/8" OSB | ||
| Interior Trim: | ||
| Floor Base - 6" VINYL COVEBASE | ||
| Floor Base Color – BLACK | ||
| Ceiling Cove - FRP PROFILES | ||
| Inside Corner - FRP PROFILES | ||
| Wall Panel Seams - FRP PROFILES | ||
| Door Trim - FRP PROFILES | ||
| Wall Color – OFF WHITE | ||
| Roof: | ||
| Roof Framing – 2x4 @ 16" O/C | ||
| Insulation – R-21 16” UNFACED FIBERGLASS BATT TYPE | ||
| Ceiling System - .030" FRP BONDED TO 3/8" OSB | ||
| Ceiling Height - 7’-6" | ||
| Exterior Doors: | ||
| 2ea – 36” x 80” Steel Door/Steel Jamb | ||
| Hardware - Keyed Lever Set Grade 2 | ||
| Hardware - Closer- Standard Grade 2 ADA Approved | ||
| Hardware – Steel Drip Cap | ||
| Hardware - Welded Tube Steel Frame to Container | ||
| Hardware - Metal Threshold with Seal | ||
| Finish - Painted | ||
| Interior Door: | ||
| 1ea – 36”X80” Prefinished Wood Hollow Core | ||
| Frame – Prefinished Wood Jamb | ||
| Hardware – 1 Passage Lever Set (Grade 3) | ||
| Hardware – Non-Mortise Hinges | ||
| Electrical: | ||
| Service – 120/208V, 3 Wire, 60Hz | ||
| Main Panel – 24 Space, NEMA 3R, EXTERIOR, 200 Amp Disconnect 120/208V 60Hz (Single or 3 Phase acceptable; remain consistent with HVAC) | ||
| Service Entrance – 2” EMT through REAR wall | ||
| Wiring System - MIN. #14 AWG (90 DEG. C COPPER WIRE) W/GROUND - ROMEX | ||
| Receptacles – | ||
| INTERIOR - 6ea GFCI PROTECTED DUPLEX GROUNDING TYPE, 125V, 15 AMP | ||
| EXTERIOR - 1ea GFCI PROTECTED DUPLEX GRND'G, 125V, 20 AMP WEATHERPROOF | ||
| Switches – | ||
| Single – 6ea 120V 15 AMP TOGGLE TYPE | ||
| Lighting: | ||
| Ceiling Lights – 6ea 4', 2-TUBE, FLUORESCENT, SURFACE MOUNT / VAPOR PROOF COVERS OR EQUIVILENT LED FIXTURES | ||
| Emergency Lights – 2ea DUAL HD EXIT/EMERGENCY LIGHT W/BATTERY PACK – UNSWITCHED | ||
| Exterior Lighting - 2ea Weatherproof Exterior Lighting (1 @ each door) | ||
| Plumbing: | ||
| Water Lines –PEX Plastic Supply, through REAR wall | ||
| Shut Off Valves – All Fixtures | ||
| Waste Lines - SCH 40 PVC Plastic, through REAR wall | ||
| Water Closet – 3ea WHITE STANDARD BOWL TANK TYPE / REAR DISCHARGE | ||
| Lavatories – 4ea 19X17 WALL HUNG W/ UPGRADE FAUCET | ||
| Showers – 3ea 32X32 ONE PIECE FIBERGLASS W/CURTAIN & P.B. MIX VALVE | ||
| Water Heaters – 2ea 80 GAL. COMMERCIAL ELEC. WTR. HTR. DOUBLE ELEMENT 208V | ||
| Drains – 1ea 3" PVC FLOOR DRAIN W/TRAP PRIMER | ||
| Modular Partitions-Toilet Fixtures - 5'H STEEL HEAD RAIL BRACED W/DOOR & LOCK, MOUNT 12" AFF | ||
| T.P. Holders – SINGLE ROLL TOILET PAPER DISPENSERS | ||
| Mirrors – 4ea 24X36 WITH STAINLESS STEEL FRAME | ||
| HVAC Unit – | ||
| Heating (Minimum Requirement) - 1ea 2-1/2 TON 208V A/C W/15KW HT | ||
| Thermostat – 1ea Wall Mounted Programmable with Tamper Resistant Cover | ||
| Supply Air Duct - INSTALLED OVERHEAD | ||
| Supply Air Diffuser – 5ea 10”X10” W/ADJUSTABLE DAMPER IN CEILING | ||
| Return Air Diffuser – 24”X14” Wall Grill | ||
| Exhaust/Vent Fans - 4ea | ||
| Fresh Air Damper – 1ea | ||
| Furniture: | ||
| Lockers - 8ea 12"X18"X78" Two-Tier Locker w/6" legs | ||
| Benches - 1ea 12’X9 1/2'X"X18"High Wood Benches | ||
| Mobility: | ||
| Containers will not have wheels | ||
| Containers must be capable of material handling (movement) by forklift, flatbed trailer, and Rough Terrain Container Handler (RTCH) | ||
| American with Disability Act (ADA) Certified | ||
| (1) 9’6”H x 8’0”W x 40'0”L Women's, non-self-contained, ground level, climate controlled, running water changing room with all amenities, complete with full height stalls, toilets, lavatories, showers, HVAC, Diamond Pattern 2.5 Vinyl or Spray-on non-skid floor surface, and dual locking access doors.Turnkey item should be delivered ready to deploy onto construction/industrial site. |
Attachment 0001 (Salient Characteristic Acknowledgement) to Combined Synopsis/Solicitation for Industrial Shredders for MCAAP
File details come from the government source that posted it.