Requirement Salient CharacteristicsVendors ability to meet the specification:(yes/no)Vendors Characteristics in Detail
Male shower, restroom & changing room container
The changing room must be of "Modified Shipping Container" type.
The changing room must be COMMERCIAL/INDUSTRIAL quality
The changing room must have ability to be moved multiple times to meet manpower requirements.
The changing room must have ability to be tied into existing water and sewer lines
The changing room must have ability to be tied into existing electrical service.
3 Showers -32"X32" One Piece Fiberglass W/Curtain & P.B Mix Valve
3 Towel Hangers
3 Toilets with T.P Dispensers and Partitions (5'H Steel Head Rail Braced W/Door & Lock, Mount 12" AFF Stalls)
4 Sinks W/Faucets
4 Mirrors - 24"X36" W/Stainless Steel Frame
2 Paper Towel Dispensers
2 Soap Dispensers
1 Wall Hung Urinal
Remove Container End Doors and Replace with Welded Corrugated Metal, match gage and style to Container Body OR Permanently seal and weld doors shut.
Exterior Coatings:
Surface Prep: Sand Blast
Paint: Envirolastic 840 DTM
Color: Desert Tan (body of container and doors)
Floors:
Insulation - R-10 Rigid Foam board
Joist - 2x6 #2 SPF or better@16” O/C /Shower Are Raised Floor
Decking – 3/4” Underlayment
Covering – Black or Gray Diamond Pattern 2.5 Vinyl or Spray-on non-skid floor surface
Walls:
Exterior Studs – 2x4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6”
Insulation - R-11 KRAFT FACED FIBERGLASS BATT TYPE
Interior Studs - 2X4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6”
Chase Walls - 2X4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6”
Covering -.030" FRP (Fiber Reinforced Plastic) BONDED TO 3/8" OSB
Interior Trim:
Floor Base - 6" VINYL COVEBASE
Floor Base Color – BLACK
Ceiling Cove - FRP PROFILES
Inside Corner - FRP PROFILES
Wall Panel Seams - FRP PROFILES
Door Trim - FRP PROFILES
Wall Color – OFF WHITE
Roof:
Roof Framing – 2x4 @ 16" O/C
Insulation – R-21 16” UNFACED FIBERGLASS BATT TYPE
Ceiling System - .030" FRP BONDED TO 3/8" OSB
Ceiling Height - 7’-6"
Exterior Doors:
2ea – 36” x 80” Steel Door/Steel Jamb
Hardware - Keyed Lever Set Grade 2
Hardware - Closer- Standard Grade 2 ADA Approved
Hardware – Steel Drip Cap
Hardware - Welded Tube Steel Frame to Container
Hardware - Metal Threshold with Seal
Finish - Painted
Interior Door:
1ea – 36”X80” Prefinished Wood Hollow Core
Frame – Prefinished Wood Jamb
Hardware – 1 Passage Lever Set (Grade 3)
Hardware – Non-Mortise Hinges
Electrical:
Service – 120/208V, 3 Wire, 60Hz
Main Panel – 24 Space, NEMA 3R, EXTERIOR, 200 Amp Disconnect 120/208V 60Hz (Single or 3 Phase acceptable; remain consistent with HVAC)
Service Entrance – 2” EMT through REAR wall
Wiring System - MIN. #14 AWG (90 DEG. C COPPER WIRE) W/GROUND - ROMEX
Receptacles –
INTERIOR - 6ea GFCI PROTECTED DUPLEX GROUNDING TYPE, 125V, 15 AMP
EXTERIOR - 1ea GFCI PROTECTED DUPLEX GRND'G, 125V, 20 AMP WEATHERPROOF
Switches –
Single – 6ea 120V 15 AMP TOGGLE TYPE
Lighting:
Ceiling Lights – 6ea 4', 2-TUBE, FLUORESCENT, SURFACE MOUNT / VAPOR PROOF COVERS OR EQUIVILENT LED FIXTURES
Emergency Lights – 2ea DUAL HD EXIT/EMERGENCY LIGHT W/BATTERY PACK – UNSWITCHED
Exterior Lighting - 2ea Weatherproof Exterior Lighting (1 @ each door)
Plumbing:
Water Lines –PEX Plastic Supply, through REAR wall
Shut Off Valves – All Fixtures
Waste Lines - SCH 40 PVC Plastic, through REAR wall
Water Closet – 3ea WHITE STANDARD BOWL TANK TYPE / REAR DISCHARGE
Urinal – 1ea WHITE WALL HUNG W/INTEGRAL TRAP & FLUSH VALVE
Lavatories – 4ea 19X17 WALL HUNG W/ UPGRADE FAUCET
Showers – 3ea 32X32 ONE PIECE FIBERGLASS W/CURTAIN & P.B. MIX VALVE
Water Heaters – 2ea 80 GAL. COMMERCIAL ELEC. WTR. HTR. DOUBLE ELEMENT 208V
Drains – 1ea 3" PVC FLOOR DRAIN W/TRAP PRIMER
Modular Partitions-Toilet Fixtures - 5'H STEEL HEAD RAIL BRACED W/DOOR & LOCK, MOUNT 12" AFF
T.P. Holders – SINGLE ROLL TOILET PAPER DISPENSERS
Mirrors – 4ea 24X36 WITH STAINLESS STEEL FRAME
HVAC Unit –
Heating (Minimum Requirement) - 1ea 2-1/2 TON 208V A/C W/15KW HT
Thermostat – 1ea Wall Mounted Programmable with Tamper Resistant Cover
Supply Air Duct - INSTALLED OVERHEAD
Supply Air Diffuser – 5ea 10”X10” W/ADJUSTABLE DAMPER IN CEILING
Return Air Diffuser – 24”X14” Wall Grill
Exhaust/Vent Fans - 4ea
Fresh Air Damper – 1ea
Furniture:
Lockers - 8ea 12"X18"X78" Two-Tier Locker w/6" legs
Benches - 1ea 12’X9 1/2'X"X18"High Wood Benches
Mobility:
Containers will not have wheels
Containers must be capable of material handling (movement) by forklift, flatbed trailer, and Rough Terrain Container Handler (RTCH)
American with Disability Act (ADA) Certified
(1) 9’6”H x 8’0”W x 40'0”L Men's, non-self-contained, ground level, climate controlled, running water changing room with all amenities, complete with full height stalls, toilets, urinal, lavatories, showers, HVAC, Diamond Pattern 2.5 Vinyl or Spray-on non-skid floor surface, and dual locking access doors. Turnkey item should be delivered ready to deploy onto construction/industrial site.
Female shower, restroom & changing room container
The changing room must be of "Modified Shipping Container" type.
The changing room must be COMMERCIAL/INDUSTRIAL quality.
The changing room must have ability to be moved multiple times to meet manpower requirements.
The changing room must have ability to be tied into existing water and sewer lines.
The changing room must have ability to be tied into existing electrical service.
Women's Room:
3 Showers - 32"X32" One Piece Fiberglass W/Curtain & P.B Mix Valve
3 Towel Hangers
4 Toilets with T.P Dispensers and Partitions (5'H Steel Head Rail Braced W/Door & Lock, Mount 12" AFF Stalls)
4 Sinks W/Faucets
4 Mirrors - 24"X36" W/Stainless Steel Frame
2 Paper Towel Dispensers
2 Soap Dispensers
Remove Container End Doors and Replace with Welded Corrugated Metal, match gage and style to Container Body OR Permanently seal and weld doors shut.
Exterior Coatings:
Surface Prep: Sand Blast
Paint: Envirolastic 840 DTM
Color: Desert Tan (body of container and doors)
Floors:
Insulation - R-10 Rigid Foam board
Joist - 2x6 #2 SPF or better@16” O/C /Shower Are Raised Floor
Decking – 3/4” Underlayment
Covering – Black or Gray Diamond Pattern 2.5 Vinyl or Spray-on non-skid floor surface
Walls:
Exterior Studs – 2x4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6”
Insulation - R-11 KRAFT FACED FIBERGLASS BATT TYPE
Interior Studs - 2X4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6”
Chase Walls - 2X4 @ 16" O/C W/SINGLE TOP & BOTTOM PLATES Height - 7’6”
Covering -.030" FRP (Fiber Reinforced Plastic) BONDED TO 3/8" OSB
Interior Trim:
Floor Base - 6" VINYL COVEBASE
Floor Base Color – BLACK
Ceiling Cove - FRP PROFILES
Inside Corner - FRP PROFILES
Wall Panel Seams - FRP PROFILES
Door Trim - FRP PROFILES
Wall Color – OFF WHITE
Roof:
Roof Framing – 2x4 @ 16" O/C
Insulation – R-21 16” UNFACED FIBERGLASS BATT TYPE
Ceiling System - .030" FRP BONDED TO 3/8" OSB
Ceiling Height - 7’-6"
Exterior Doors:
2ea – 36” x 80” Steel Door/Steel Jamb
Hardware - Keyed Lever Set Grade 2
Hardware - Closer- Standard Grade 2 ADA Approved
Hardware – Steel Drip Cap
Hardware - Welded Tube Steel Frame to Container
Hardware - Metal Threshold with Seal
Finish - Painted
Interior Door:
1ea – 36”X80” Prefinished Wood Hollow Core
Frame – Prefinished Wood Jamb
Hardware – 1 Passage Lever Set (Grade 3)
Hardware – Non-Mortise Hinges
Electrical:
Service – 120/208V, 3 Wire, 60Hz
Main Panel – 24 Space, NEMA 3R, EXTERIOR, 200 Amp Disconnect 120/208V 60Hz (Single or 3 Phase acceptable; remain consistent with HVAC)
Service Entrance – 2” EMT through REAR wall
Wiring System - MIN. #14 AWG (90 DEG. C COPPER WIRE) W/GROUND - ROMEX
Receptacles –
INTERIOR - 6ea GFCI PROTECTED DUPLEX GROUNDING TYPE, 125V, 15 AMP
EXTERIOR - 1ea GFCI PROTECTED DUPLEX GRND'G, 125V, 20 AMP WEATHERPROOF
Switches –
Single – 6ea 120V 15 AMP TOGGLE TYPE
Lighting:
Ceiling Lights – 6ea 4', 2-TUBE, FLUORESCENT, SURFACE MOUNT / VAPOR PROOF COVERS OR EQUIVILENT LED FIXTURES
Emergency Lights – 2ea DUAL HD EXIT/EMERGENCY LIGHT W/BATTERY PACK – UNSWITCHED
Exterior Lighting - 2ea Weatherproof Exterior Lighting (1 @ each door)
Plumbing:
Water Lines –PEX Plastic Supply, through REAR wall
Shut Off Valves – All Fixtures
Waste Lines - SCH 40 PVC Plastic, through REAR wall
Water Closet – 3ea WHITE STANDARD BOWL TANK TYPE / REAR DISCHARGE
Lavatories – 4ea 19X17 WALL HUNG W/ UPGRADE FAUCET
Showers – 3ea 32X32 ONE PIECE FIBERGLASS W/CURTAIN & P.B. MIX VALVE
Water Heaters – 2ea 80 GAL. COMMERCIAL ELEC. WTR. HTR. DOUBLE ELEMENT 208V
Drains – 1ea 3" PVC FLOOR DRAIN W/TRAP PRIMER
Modular Partitions-Toilet Fixtures - 5'H STEEL HEAD RAIL BRACED W/DOOR & LOCK, MOUNT 12" AFF
T.P. Holders – SINGLE ROLL TOILET PAPER DISPENSERS
Mirrors – 4ea 24X36 WITH STAINLESS STEEL FRAME
HVAC Unit –
Heating (Minimum Requirement) - 1ea 2-1/2 TON 208V A/C W/15KW HT
Thermostat – 1ea Wall Mounted Programmable with Tamper Resistant Cover
Supply Air Duct - INSTALLED OVERHEAD
Supply Air Diffuser – 5ea 10”X10” W/ADJUSTABLE DAMPER IN CEILING
Return Air Diffuser – 24”X14” Wall Grill
Exhaust/Vent Fans - 4ea
Fresh Air Damper – 1ea
Furniture:
Lockers - 8ea 12"X18"X78" Two-Tier Locker w/6" legs
Benches - 1ea 12’X9 1/2'X"X18"High Wood Benches
Mobility:
Containers will not have wheels
Containers must be capable of material handling (movement) by forklift, flatbed trailer, and Rough Terrain Container Handler (RTCH)
American with Disability Act (ADA) Certified
(1) 9’6”H x 8’0”W x 40'0”L Women's, non-self-contained, ground level, climate controlled, running water changing room with all amenities, complete with full height stalls, toilets, lavatories, showers, HVAC, Diamond Pattern 2.5 Vinyl or Spray-on non-skid floor surface, and dual locking access doors.Turnkey item should be delivered ready to deploy onto construction/industrial site.