Drawing - 11B5090106revA.pdf

PDF 115 KB Posted

Attached to
Air Tanks Federal contract opportunity
Solicitation number
W519TC-24-Q-2069
Issued by
Department of the Army Materiel Command Contracting Command Rock Island Arsenal

About this file

This document contains a vendor item control drawing for a 20 gallon, 200 PSI vertical air tank to be supplied under Department of the Army Materiel Command Contracting Command Solicitation W519TC-24-Q-2069 for air tanks. The drawing specifies the key features of the air tank as having a 20 gallon nominal capacity and 200 PSI minimum pressure rating, with access ports and bolt patterns located as indicated. Dimensions shall be within specified tolerances and the overall space envelope shall be no larger than 16 inches wide by 16 inches long by 38 inches high. Any additional outlets not specified by size and thread shall be sealed to withstand the tank's maximum pressure rating.

View the file

Other files for this federal contract opportunity

Other files attached to Air Tanks, newest first.
File Type Posted
Attachment 0001 - Price Matrix.xlsx XLSX spreadsheet
W519TC-24-Q-2069.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1/4" NPT

APPROX LOCATION

3/4" NPT

APPROX LOCATION

35.59

14.95

14.00

3/4" NPT

APPROX LOCATION

10.39+ .03 .12

10.39±1.50

1/2" NPT

APPROX LOCATION

SUGGESTED SOURCE OF SUPPLY

PART

NUMBER

VENDOR DATA

NAME & ADDRESS CAGE CODE VENDOR

PART NO. DESCRIPTION

11B5090106

MANCHESTER TANK

1000 CORPORATE CENTRE DRIVE

SUITE 300

FRANKLIN, TN 37067

615-370-6300

4FDC0 302404 20 GALLON, 200 PSI, VERTICAL

AIR TANK

SALIENT FEATURES

CAPACITY 20 GALLON NOMINAL

PRESSURE RATING 200 PSI MINIMUM

ACCESS PORTS AS INDICATED

BOLT PATTERN AS INDICATED

SPACE ENVELOPE NO LARGER THAN 16" WIDE BY 16" LONG BY 38"

HIGH

SPECIAL FEATURE

ANY ADDITIONAL OUTLETS IN THE AIR TANK,

NOT SPECIFIED BY SIZE AND THREAD, SHALL BE

SEALED WITH FITTINGS THAT CAN WITHSTAND

THE TANK'S MAXIMUM PRESSURE RATING

REVISIONS

LTR NOR NUMBER DATE APPROVED

- NOR 738-0001-001 2014-04-25 PMS

A 738-0133-001 2017-02-14 PMS

DWG NO.

U.S. ARMY RESEARCH, DEVELOPMENT AND ENGINEERING COMMAND

ROCK ISLAND ARSENAL, ROCK ISLAND, IL 61299

EDGEWOOD CHEMICAL BIOLOGICAL CENTER

CONTRACT NO.

5B5M3

CAGE CODE

D

SIZE

3 PLACE DECIMALS ±

2 PLACE DECIMALS ±

SHEETSCALE

DRAWING APPROVAL

DESIGN APPROVAL

SUBMITTED

CHECKERDRAWN BY

ORIGINAL DATE

MATERIAL

TOLERANCES ON:

DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED

EQUIPMENT CODE NO.

NEXT ASSY

8 7 6 5 4 3 2 1

8 7 6 5 4 3 2 1

D

C

B

A

D

C

B

A

FRACTIONS

11B5090106

2011-07-26

1:4

R. McCLAIN

R. McCLAIN

M. BLOSSER

P. SCHLUE

(YR-MO-DA)

VENDOR ITEM CONTROL DRAWING

ANGLES ±

AIR TANK

Q. HARTMAN

11B5190852

NOTES

APPLICABLE STANDARDS/SPECIFICATIONS:1.

ASME Y14.100-2004A.

ASME Y14.5-2009B.

IDENTIFICATION OF THE SUGGESTED SOURCE(S) OF SUPPLY 2.

HEREON IS NOT TO BE CONSTRUED AS A GUARANTEE OF PRESENT

OR CONTINUED AVAILABILITY AS A SOURCE OF SUPPLY FOR THE

ITEM DESCRIBED ON THE DRAWING.

VENDOR PART NUMBER(S) ARE FOR REFERENCE ONLY. DRAWING 3.

SPECIFICATIONS AND DIMENSIONAL REQUIREMENTS SUPERCEDE

VENDOR PART NUMBER(S) AND/OR CATALOG CALLOUTS.

DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITED.

REV: A

Sheet1
Drawing View11
Drawing View12
Drawing View13

File details come from the government source that posted it. Updated .