W50S9A-23-Q-0004 SOW-Office Furniture Layout.pdf

PDF 1 MB Posted

Attached to
Office Furniture- 151 ISRG Bldgs. 302 & 304
Solicitation number
W50S9A-23-Q-0004
Issued by

About this file

This statement of work outlines furniture requirements for several offices within two buildings at Roland R. Wright Air National Guard Base. The solicitation seeks a contractor to provide modular furniture systems, individual workstations, desks, storage units, seating, and accessories. Key requirements include electric height-adjustable desks, modular walls, and overhead storage components for several module workstations within building 304. Additional items such as wardrobes, lounge seating, and conference tables are specified for individual offices in buildings 302 and 304. The statement of work provides layout diagrams and minimum specifications for each furniture component. The selected contractor must perform design, delivery, assembly, installation, and waste removal services. The period of performance is 30 days from contract award. Work will be conducted on base under security escort and adhere to facility access procedures.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

3 May 2023

169 IS Bldg. 302 and 304

1. GENERAL: This is a 169th Intelligence Squadron (IS) requirement to provide new office layouts and furniture to buildings 302/304 and provide incidental installation services.

2. DESCRIPTION OF SERVICES: The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, other items, and non-personal services necessary to provide and install office furniture for the 151st IS Asia flight and IS command staff sections as defined in this Statement of Work.

3. BACKGROUND: The 169th IS provides high-quality Intelligence to the Airforce and Intel enterprise.

- Innovation – Expertise. These areas within the 169 IS are crucial to the intelligence mission in supporting on-going mission, development, and growth.

4. TASKS:

a. Planning/Design. The contractor shall be able to provide design services, including space planning layouts, site verification, material selection and programming as necessary for each section. See the provided workspace layouts that show the approximate requirements of each space.

b. Equipment/Materials. The Contractor shall provide all support needed to include onsite labor, equipment, tools, materials, and any other resources needed to accomplish the required work.

c. General Requirements. Mid-grade commercial furniture. No wood, all furniture shall be metal, laminate, plastic, or composite materials unless otherwise specified in the description below. Finish shall be basic – no premium finishes.

d. Period of Performance. Contractor shall provide a known start date and schedule no later than 30 days after contract award.

e. Project Manager. The contractor shall provide a project manager who shall be responsible for and be a single point of contact for the performance of work. The name of this person and an alternate or alternates shall be provided to the contracting officer (CO) within five (5) business days after contract award. The contract manager or alternate shall have full authority to act for the contractor on all contract matters relating to the daily operations of this contract on the installation.

W50S9A-23-Q-0004 SOW-Furniture Layout

f. Installation and Removal Services.

i. All existing furniture will be removed by government personnel prior to the start of work.

ii. The contractor shall be escorted by 151 ISRG personnel when working within the ISRG compound (bld. 302 and 304).

iii. During installation, the contractor shall protect all furniture and building materials, to include carpet, existing within the space with industry approved protective coverings.

Contractor shall be liable for any damage to government property caused by the contractor or their representatives.

iv. The contractor shall uncrate/unpack all new items, dispose of packing material off the installation, and perform required assembly in accordance with the manufacturer instructions.

v. Services shall include inspection of product for shipping damage. If damage is found it shall be the responsibility of the contractor to make all arrangements for replacement or repair of the item(s) damaged. Damaged items shall not be installed.

vi. The contractor shall assemble/install the new furniture in accordance with this requirement statement, and the basic component layout as provided by the contractor.

vii. The contractor shall provide all new components, completely assembled, installed, and operational, including keys for each individual lock set and a master key to fit all lock sets.

viii. New furniture, equipment, and accessories shall be level, square, and in proper alignment with adjoining furniture. All drawers shall operate smoothly and stay closed when not in use.

ix. Prior to acceptance, the contractor shall clean all new furniture only with the manufacturer's recommended cleaning agents/products and inspect to ensure the new furniture is free of surface dirt and defects.

5. Technical Requirements:

a. Layout Plans. The included layouts in section 14. ROOM LAYOUTS are not to exacting specifications. They are intended to provide approximate measurements of each space and a rough drawing of how the furniture should be arranged. The Contractor shall be responsible for actual measurements, design, and fitment of the office furniture within the designated spaces.

The contractor shall install workstations and other furniture in accordance with the provided layout diagrams.

b. Module Furniture Building 304: Asia Flight Modules (Module MA, MB, and MC). Each module should be approximately 13ft x 20ft. Module walls with inward swinging doors shall closely line building walls and shall have power whips and the ability to have cables concealed/run throughout the wall (cable raceways). The wall that separates modules MB-MC should be approximately 4ft tall. All desks within the modules shall line the inside of the walls creating a continuous worksurface and shall be electric height adjustable desks with cord management. Each desk shall have an office chair and a 3 drawer mobile pedestal. The provided office furniture shall be free standing and shall not be attached/mounted to the module or building walls. Each furniture item shall meet or exceed the salient characteristics and minimum size requirements as stated but shall not be so large that it impedes on the functionality of the space. The following are the minimum salient characteristics and size requirements of the office furniture that shall be included:

Product Minimum Requirement Qty I. Cubicle Walls with power whips and cable raceways (surrounding walls and between modules MA and MB)

84in Tall 9

II. Cubicle Wall with power whip and cable raceways (between MB and MC)

48in Tall 1

III. Cubicle doors

Doors shall match the height of the front cubicle wall and swing inward min 36in W

IV. Height adjustable mesh office chair with tilt tension settings and multifunction/adjustable arms

Minimum weight capacity 200lbs

V. Electric height adjustable desks with cord management

60in L x 24in W 27

VI. Mobile Pedestals 3 Drawers 24

Office Furniture Building 304: Office 1 (O1). Office is approximately 12ft x 9ft 6in. Office shall have one electric height adjustable desk for the eastern portion, a L-shaped continuous fixed desk/worksurface and attached overhead storage hutch with outward swinging doors for the western portion against the wall, 3 drawer mobile pedestal, a mesh office chair, two door wardrobe in the southwest corner, and an office couch/sofa. The provided office furniture shall be free standing and shall not be attached/mounted to the building walls. Each furniture item shall meet or exceed the salient characteristics and minimum size requirements as stated but shall not be so large that it impedes on the functionality of the space. The following are the minimum salient characteristics and size requirements of the office furniture that shall be included:

Product Minimum Requirement Qty VI. Electric height adjustable desk with cord management 60in L x 24in W 1

VII. L-shaped continuous desk/worksurface with attached overhead storage hutch with outward swinging doors

This desk/worksurface should line the north wall from the height adjustable desk to the back west wall across to the wardrobe approx. 72in L x 24in W

(hutch should be above the western portion against the wall)

VIII. Mobile Pedestal 3 Drawers 1 IX. Two door wardrobe with interior hanging rods and adjustable shelving 72in H X 36in W X 36in D 1

X. Height adjustable mesh office chair with tilt tension settings and multifunction/adjustable arms

Minimum weight capacity 200lbs

XI. office couch/sofa 3 seats 1

Office Furniture Building 304: Office 2 (O2). Office is approximately 12ft x 9ft 6in. Office shall have two L-shaped electric height adjustable desks, one in the northeast corner and one in the southwest corner, a L-shaped continuous fixed desk/worksurface and attached overhead storage hutch with outward swinging doors in the south east corner, two mobile pedestals, and two mesh office chairs.

Product Minimum Requirement Qty XII. L-shaped electric height adjustable desks with cord management 60in L x 60inL x 24in W 2

XIII. L-shaped continuous desk/worksurface with attached overhead storage hutch with outward swinging doors

This desk/worksurface should line the southeast corner approx. 72in L x 24 in W (hutch should be above each portion against wall)

XIV. Height adjustable mesh office chair with tilt tension settings and multifunction/adjustable arms

Minimum weight capacity 200lbs

Office Furniture Building 302 IS Command: Office 3 (O3) Office is approximately 13ft x 8ft.

Office shall have one electric height adjustable desk for the southern portion, a L-shaped continuous fixed desk/worksurface and attached overhead storage hutch with outward swinging doors for the western/northwestern portion against the wall, 3 drawer mobile pedestal, a mesh office chair, and two door wardrobe in the northeast corner. The provided office furniture shall be free standing and shall not be attached/mounted to the building walls.

Each furniture item shall meet or exceed the salient characteristics and minimum size requirements as stated but shall not be so large that it impedes on the functionality of the space. The following are the minimum salient characteristics and size requirements of the office furniture that shall be included:

Product Minimum Requirement Qty XV. Electric height adjustable desk with cord management 60in L x 24in W 1

XVI. L-shaped continuous desk/worksurface with attached overhead storage hutch with outward swinging doors

This desk/worksurface should line the west wall from the height adjustable desk to the back north wall across to the wardrobe approx. 72in L x 24in W

(hutch should be above the northern portion against the wall)

XVII. Mobile Pedestal 3 Drawers 1 XVIII. Two door wardrobe with interior hanging rods and adjustable shelving 72in H X 36in W X 36in D 1

XIX. Height adjustable mesh office chair with tilt tension settings and multifunction/adjustable arms

Minimum weight capacity 200lbs

Office Furniture Building 302 IS Command: Office 4 (O4) Office is approximately 11ft x 19ft 6in.

Office shall have one electric height adjustable desk for the northern portion, a L-shaped continuous fixed desk/worksurface and attached overhead storage hutch with outward swinging doors for the eastern/southeastern portion against the wall, 3 drawer mobile pedestal, a mesh office chair, two 3 seat couches/sofas, and two single lounge chairs. The provided office furniture shall be free standing and shall not be attached/mounted to the building walls. Each furniture item shall meet or exceed the salient characteristics and minimum size requirements as stated but shall not be so large that it impedes on the functionality of the space. The following are the minimum salient characteristics and size requirements of the office furniture that shall be included:

Product Minimum Requirement Qty XX. Electric height adjustable desk with cord management 60in L x 24in W 1

XXI. L-shaped continuous desk/worksurface with attached overhead storage hutch with outward swinging doors

This desk/worksurface should line the east wall from the height adjustable desk to the back south wall across to approx. 72in L x

60in L x 24in W (hutch should be above the southern portion against the wall)

XXII. Mobile Pedestal 3 Drawers 1 XXIII. Height adjustable mesh office chair with tilt tension settings and multifunction/adjustable arms

Minimum weight capacity 200lbs

XXIV. Office sofas/couches 3 seats 2 XXV. Single lounge chairs - 2

Office Furniture Building 302 IS Command: Office 5 (O5) Office is approximately 14ft 6in x 10ft.

Office shall have one electric height adjustable desk for the northern portion, a L-shaped continuous fixed desk/worksurface and attached overhead storage hutch with outward swinging doors for the western/southwestern portion against the wall, 3 drawer mobile pedestal, a mesh office chair, and two door wardrobe in the southeast corner away from the door. The provided office furniture shall be free standing and shall not be attached/mounted to the building walls. Each furniture item shall meet or exceed the salient characteristics and minimum size requirements as stated but shall not be so large that it impedes on the functionality of the space. The following are the minimum salient characteristics and size requirements of the office furniture that shall be included:

Product Minimum Requirement Qty VI. Electric height adjustable desk with cord management 60in L x 24in W 1

VII. L-shaped continuous desk/worksurface with attached overhead storage hutch with outward swinging doors

This desk/worksurface should line the west wall from the height adjustable desk to the back south wall across approx. 72in L x 60in L x 24in W (hutch should be above the southern portion against the wall)

VIII. Mobile Pedestal 3 Drawers 1 IX. Two door wardrobe with interior hanging rods and adjustable shelving 72in H X 36in W X 36in D 1

X. Height adjustable mesh office chair with tilt tension settings and multifunction/adjustable arms

Minimum weight capacity 200lbs

6. QUALITY ASSURANCE: The Contractor shall be responsible for implementing and maintaining a Quality Control Program (QCP) to ensure that the work performed meets or exceeds contract requirements and results in the correction of potential and actual problems.

7. GOVERNMENT SERVICES:

a. General Services. The Government will not provide any general services.

b. Facilities & Utilities. The government will provide a staging area to adequately sort, stage and uncrate products and electrical power, working lights, heating, and air conditioning in the working area for use during installation. Government will ensure that the work area is ready for product installation. The Government will not provide an area to store the product prior to installation. The contractor will receive/store all items at their facility and deliver on the date of install.

c. Materials & Equipment. The Government will not provide any materials and equipment.

d. Housekeeping. The Government will not provide any housekeeping.

8. BASE & BUILDING ACCESS: For all Contractor employees to work on Roland R. Wright Air National Guard Base, the Contractor’s proposal shall include the ability for all Contractor personnel performing work under this purchase order to routinely access the base.

a. Contractor shall submit a complete list of personnel in accordance with installation policy, including delivery-persons, who will be expected to work on the installation no less than three

(3) business days prior to accessing the installation.

b. Current rules and regulations applicable to the premises where the work will be performed shall apply to the Contractor and its employees while working on the premises. These regulations include, but are not limited to, presenting valid identification for personnel and vehicular entrance, smoking restrictions and any safety procedures as outlined in the installation regulations.

c. The Contractor shall keep within the established limits of work and avenues of ingress and egress. The Contractor shall ensure their personnel working on Roland R. Wright Air National Guard Base become familiar with and obey all Roland R. Wright Air National Guard Base requirements and regulations including, but not limited to, safety, fire, traffic and security. The Contractor shall not enter any restricted areas unless required to do so and until cleared for such entry. The Contractor shall ensure Contractor equipment is conspicuously marked for identification.

d. Vehicle registration, proof of insurance and a valid driver’s license shall be presented to gain base access.

9. FEDERAL HOLIDAYS:

If the federal holiday falls on a Saturday, the holiday is observed on the proceeding Friday. If the federal holiday falls on a Sunday, the holiday is observed on the following Monday. If desired, the Contractor is allowed to work on a federal holiday once the Contractor has requested approval in writing to the technical point of contact (TPOC) with an approval response provided.

10. HOURS OF OPERATION: Normal hours of operation are 7:00 am through 4:00 pm, Monday through Thursday and exclude Federal Holidays. Deviations from the hours specified above may be requested by the Contractor to be submitted to the TPOC. The Contractor shall give notice of the deviation of hours to the TPOC at least two (2) business days in advance of the proposed change.

11. PLACE OF PERFORMANCE: The work to be performed under this contract will be performed at the Roland R. Wright Air National Guard Base in building 302 and 304 for the 169 IS. The base address is 765 N 2200 W, Salt Lake City, UT. 84116

12. SECURITY REQUIREMENTS: Contractor personnel performing work under this contract must always have an escort with a TS SCI, at a minimum. Contractor shall not provide the military organization name, location or identity to the manufacturer and shipper.

13. PHYSICAL SECURITY: At the close of each work period, government facilities, equipment, and materials shall be secured.

14. ROOM LAYOUTS: The included layouts in this section are not to exacting specifications.

They are intended to provide approximate measurements of each space and be a rough drawing of how the furniture should be arranged based upon the furniture requirements of section 5. Technical Requirements.

I. Cubicle Walls with power whips and cable raceways (surrounding walls and between modules MA and MB) Minimum 84in Tall

II. Cubicle Wall with power whip and cable raceways (between MB and MC) Minimum 48in Tall

Bldg. 304

Bldg. 302

File details come from the government source that posted it. Updated .