Salient Characteristics.docx
DOCX document 13 KB Posted
- Attached to
- 120AW SFS Guard Shacks Federal contract opportunity
- Solicitation number
- W50S7L23Q0006
- Issued by
- Department of the Army National Guard
About this file
This document outlines requirements for a mobile structure to be procured by the 120th AW/SF of the Montana Air National Guard. The structure must be pre-assembled and mobile with 80-100 square feet of interior space. It must be transportable via a 3/4 ton vehicle and include anchoring for securement to a trailer. All six sides of the structure, including walls, floor, and ceiling, must have at least R10 insulation and UL 752 Level 3 bullet resistance. Interior finishes include galvanized diamond plate flooring on a steel base frame and commercial grade painted walls and ceilings. Windows must also have UL 752 Level 3 bullet resistance and include tinting. An insulated and armored door is required with a number pad entry lock. Additional requirements include a 5000 watt or higher generator, HVAC, electrical panel, lighting, smoke/CO detectors, fixed interior desks, and exterior flood lights. The related federal contract opportunity is solicitation number W50S7L23Q0006 being procured by the Department of the Army National Guard for 120AW SFS Guard Shacks.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
The 120th AW/SF is requesting a fully pre-assembled, mobile structure with approx. 80-100 sq feet in area. Mobile structure will be able to be moved by 3/4 ton GOV or equivalent vehicle for transportation purposes. Mobile structure will have a securing device to trailer. (i.e. anchoring system) Walls must be insulated with at least 2 inches of weather resistant R10 or higher insulation, the floor and roof will additionally have the same R10 or higher insulation. All six sides (four walls, floor, and ceiling) will have UL 752 Bullet resistance or equivalent protection through credible accreditation standard (i.e. (NIJ) National Institute of Justice). Interior floor will have galvanized diamond floor plate on steel fork liftable base-frame. Walls will be finished with commercial grade rust resistant paint with a commercial grade finish paint in indigo blue exterior and light gray interior. All windows will have the same or higher UL 752, Level 3 bullet resistance standard to include being fixed. It is preferable to have full 360 degree of surveillance, as much surveillance capability as possible. Windows can vary in approximate size but 36” tall is preferable. All windows will be tinted with a one-way window film, black-out or frosted. Mirror one-way film will not be used. Door must swing to the outside in either direction preferable size 32” wide, 80” tall with UL752 Level 3 bullet resistance protection and R10 equivalent or higher insulation rating. A commercial door closer will be attached with a lockable doorhandle. Locking device will be a number pad entry system. A window will be added to door, with UL752 Level 3 bullet resistance protection, to keep as much 360 surveillances as possible. A 5000 watt or higher gas/diesel generator is a primary source of electricity. The generator size will be appropriated to fit a HVAC system (i.e. BTU to square area size. Heating and air conditioning is a must. A shroud cover meeting same bullet resistant as the main frame walls will cover outside HVAC system. A duplex Ethernet port and phone line will be installed with exterior connection capability. An electric disconnect switch (30amp) located on the outside is necessary to connect to a breaker panel box (125 Amp) located interior of the structure. The breaker Panel box will be rated for 125 Amp. A smoke and carbon monoxide detector is a must. The Panel box will be connected interior to two 110v quad outlet, one on each wall not containing doors (under the desks). Two to three lights will be fixed to the interior and four exterior flood lights for nighttime operations. LED is required for all lighting. Two fixed desks on walls not containing doors, the length of the wall, with two drawers each. Contractors will cover shipping from build location to Montana Air National Guard. There is no requirement for a trailer to be included in the requirement just the ability to be secured to a trailer.
File details come from the government source that posted it. Updated .