This statement of work describes requirements for a Vindicator intrusion detection system, access control system, and CCTV installation at Building 2071 on Robins Air Force Base in Georgia. The contractor must provide a site survey, install a Honeywell Vindicator IDS and ACS panels and supporting infrastructure. This includes two Vindicator Windows 10 workstations, PIR sensors, keypads, and a V5 panel. The contractor must also provide a badge manager system, 14U locking cabinet, and KVM extenders. The offer due date is August 31, 2023. The selected contractor must be a Honeywell Vindicator certified installer and perform testing, training and warranty services. The federal agency is the Department of the Army National Guard.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| VINDICATOR IDS B2071 QA.docx | DOCX document | |
| 116 ACW Base Map.pdf | ||
| 116 ACW Base Map.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEE ADDENDUM
(No Collect Calls)
W50S6Z23R0009
b. TELEPHONE NUMBER
478-201-1210
8. OFFER DUE DATE/LOCAL TIME
02:00 PM 31 Aug 2023
5. SOLICITATION NUMBER 6. SOLICITATION ISSUE
DATE 1-Aug-2023
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
STANDARD FORM 1449 (REV. 2/2012)
Prescribed by GSA – FAR (48 CFR) 53.212
(TYPE OR PRINT)
(SIGNATURE OF CONTRACTING OFFICER)
ADDENDA ARE
26. TOTAL AWARD AMOUNT (For Gov t. Use Only )
23.
CODE 10. THIS ACQUISITION IS
SUCH ADDRESS IN OFFER
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT
BELOW IS CHECKED
TELEPHONE NO.
W50S6Z9. ISSUED BY
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK
7. FOR SOLICITATION
INFORMATION CALL:
a. NAME
CODY SCHWART
2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER
(TYPE OR PRINT)
30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER
30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA
0 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.
25. ACCOUNTING AND APPROPRIATION DATA
1. REQUISITION NUMBER
20.
ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.
OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
ARE NOT ATTACHED
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED
(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE
SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:
. YOUR OFFER ON SOLICITATION
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN
% FOR:SET ASIDE:UNRESTRICTED OR X
SMALL BUSINESSX
17a.CONTRACTOR/ CODE FACILITY
OFFEROR CODE
USPFO GA 116 MISSION SUPPORT CONTRACTING
540 EAST DRIVE
ROBINS AFB GA 31098-1833
18a. PAYMENT WILL BE MADE BY CODE
RATED ORDER UNDER
DPAS (15 CFR 700)
13a. THIS CONTRACT IS A
13b. RATING
CODE15. DELIVER TO CODE F6X3D2 16. ADMINISTERED BY
12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-
TION UNLESS BLOCK IS
MARKED
SEE SCHEDULE
14. METHOD OF SOLICITATION
RFQ IFB RFPX
116 ACW/COMMUNICATIONS F6X3D2
RANDALL EVANS
525 BORGHESE DRIVE
BLDG 2079
ROOM 5
ROBINS AFB GA 31098
TEL: 478-201-4320 FAX:
FAX:
TEL: SERVICE-DISABLED
VETERAN-OWNED
SMALL BUSINESS
8(A)
HUBZONE SMALL
BUSINESS
SIZE STANDARD:
1,250
NAICS:
334111
X
OFFER DATED
29. AWARD OF CONTRACT: REF.
DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY
COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND
EMAIL:
TEL:
31c. DATE SIGNED
SEE SCHEDULE
SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT
24.22.21.19.
WOMEN-OWNED SMALL BUSINESS (WOSB)
ELIGIBLE UNDER THE WOMEN-OWNED
SMALL BUSINESS PROGRAM
EDWOSB
32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
(CONTINUED)
PAGE 2 OF66
ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________
32a. QUANTITY IN COLUMN 21 HAS BEEN
RECEIVED INSPECTED
32b. SIGNATURE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE
37. CHECK NUMBER
FINALPARTIALCOMPLETE
36. PAYMENT35. AMOUNT VERIFIED
CORRECT FOR
34. VOUCHER NUMBER
FINAL
33. SHIP NUMBER
PARTIAL
38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY
41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT
41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE
42a. RECEIVED BY (Print)
42b. RECEIVED AT (Location)
42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS
STANDARD FORM 1449 (REV. 2/2012) BACK
Prescribed by GSA – FAR (48 CFR) 53.212
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
SEE SCHEDULE
20.
SCHEDULE OF SUPPLIES/ SERVICES
21.
QUANTITY UNIT
22. 23.
UNIT PRICE
24.
AMOUNT
19.
ITEM NO.
Section B - Supplies or Services and Prices
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
0001 1 Job Vindicator IDS B2071
FFP
Requirements Desciption - Vindicator Intrusion Detection System, Access Control System (ACS), and CCTV.
Please refer to the SOW & Attachment 1 for further requirement description.
FOB: Destination
MFR PART NR: VINDICATOR
PSC CD: 6350
NET AMT
Section C - Descriptions and Specifications
VINDICATOR IDS B2071 SOW
STATEMENT OF WORK
(SOW)
For Vindicator Intrusion Detection System Installation
Services
For
Bldg 2071 IDS Vindicator Upgrade Robins (ANG) Air Force Base, Georgia
1. DESCRIPTION OF WORK: This Statement of Work (SOW) describes the Government’s requirement for a site survey for quote and installation of a Honeywell Vindicator Intrusion Detection System (IDS), Access Control System (ACS) and CCTV by a Honeywell Vindicator certified installer. The system will be designed to meet the physical security compliance requirements of the Air Force Instruction (AFI) 31-101, Intelligence Community Directive (ICD) ICD-705, Robins (ANG) AFB specifications, and ESE-SIT-0001 for protection of assets. The contractor shall provide all necessary infrastructure upgrades to support systems operations. The contractor shall provide ancillary equipment, materials and/or supplies needed for the installation and associated infrastructure. The contractor shall ensure that the system delivered under this contract consists of already proven (qualified) Commercial Off The Shelf (COTS) equipment from the Non-Nuclear, Intrusion Detection System (IDS) Non-Nuclear Configuration Management Database (CMD) published by Air Force Security Forces Center (AFSFC) installed in the approved and tested configuration; and/or, non-CMD COTS IDS equipment proposed, qualified and proven by the contractor and accepted (Approved) by the Government as satisfying system requirements. The contractor shall perform contractor Verification Testing of the system and subsystems to include information assurance verification and stability testing IAW ESE-SIT-0001 Test and Turnover Plan. Contractor shall validate contractor supplements to commercial technical manuals and support all phases of Government acceptance testing and provide site-specific training personnel. The contractor shall provide factory equipment staging services, onsite Programming, testing, and training for Vindicator equipment. The contractor shall provide project management for sub-contractors and onsite personnel.
1.1 GENERAL REQUIREMENTS INTRUSION DETECTION SYSTEM (IDS): The contractor shall procure and install an IDS and ACS panels and all supporting infrastructure. All Vindicator Panels require tamper alarms to be embedded in them in accordance with AFI 31-101. The contractor shall procure and install 2 Vindicator Windows 10 Workstation Vindicator Command and Controls (VCCs). The VCCs require a mapping Graphical User Interface (GUI) to monitor alarm activation locations. The contractor shall install the following IDS equipment. BMS on the doors, PIR sensors, and keypad for IDS, keypad for ACS, and a V5 panel. This will require any additional communication lines run to the facility for the panel to communicate with the Headend and Redundant VCC. An Uninterruptable Power Supply (UPS) is required for IDS. The UPS will be configured to meet the needs of the facility during the site survey.
1.2 ANNUNCIATOR REQUIREMENTS: The contractor shall meet the following annunciation requirements:
The VCC shall be installed in accordance with OEM instructions and Section 4 ESE-SIT-0001.
The VCC shall provide error detection, line supervision, and system control continuously.
The VCC shall display the following:
The status either automatically as changes occur, or when manually initiated by the operator.
The highest priority alarm, according to user-defined parameters, in the queue regardless of arrival sequence.
The alarm type, physical location, and sector or zone.
At a minimum display the highest five (5) alarms text in the queue.
Graphics for all alarms received.
Alarm priority as programmed by the system administrator.
Up to five (5) simultaneous alarms within (5) seconds.
The VCC shall have 100% tamper detection and the capability for a duress alarm, 100% correct annunciation of alarms.
The VCC shall archive and store all status changes and operator actions including maintenance periods, alarms, and sensor access attempts.
Removable, non-volatile, mass storage media shall be located at the user console.
Internal storage shall have a minimum 30-day capacity.
The VCC shall have a re-initialization time of less than ten (10) minutes.
Text, graphics indications, and total system status shall update automatically when changes occur or when requested by the operator.
Visual indications shall include access/secure/alarm conditions, video loss, line supervision status, power source in use, and self-test indications, through the use of text and graphics.
The VCC shall conduct system tests and diagnostics which are automatically and randomly generated every six to eight hours and/or manually generated by the operator at any time.
The VCC shall provide unique audible tones for sensor alarm conditions and other changes in the status.
1.3 BADGE AND ENROLLMENT STATION: The contractor shall provide and install a Vindicator Badge Manager 3.
This system shall have a camera, printer options and consumables, and 500 blank credentials for badge creations, enrollment, and project Access Control System (ACS) Administration and Management. The new system must have the capacity to accommodate enrolled and active individuals. When the new system is implemented, all badges must be compatible with all installed card readers. All existing access control devices, as well as any new feeds added under this statement of work, must be integrated and functional in the new enrollment station. The contractor shall provide a Vindicator AE AES ACS v5 panel, and 14U locking 4-post cabinet with tamper switches to house the Vindicator badge Manager. The contractor shall provide KVM Extenders to remote the desktop / enrollment peripherals. Cabinet tampers will be terminated to the ACS V5 panel. The contractor shall provide a battery backup for the provided equipment for a calculated 4-hour battery run time.
2. GENERAL INFORMATION:
2.1 NORMAL HOURS OF OPERATION. The Government’s normal duty hours are five days per week, Monday through Friday, from 7:30 AM to 4:30 PM. However, the Command Post functions on a 24/7 operations schedule.
2.1.1. RECOGNIZED HOLIDAYS. Any of the below holidays falling on a Saturday will be observed on the preceding Friday; holidays falling on a Sunday will be observed on the following Monday.
New Year’s Day 1 January Martin Luther King's Birthday Third Monday in January President's Day Third Monday in February Memorial Day Last Monday in May Independence Day 4 July
Labor Day First Monday in September Columbus Day Second Monday in October Veterans Day 11 November Thanksgiving Day Fourth Thursday in November Christmas Day 25 December
2.2. LISTING OF EMPLOYEES. The contractor shall maintain a current listing of employees. Access to restricted areas will be coordinated by the 116 APO and owner user as needed.
2.2.1. SECURITY TRAINING. The contractor shall ensure all contractor employees are made available to receive initial and recurring security education training from the sponsoring agencies security manager. Training must be conducted IAW DOD 5200.1-R, Information Security Program Regulation, and AFI 31- 401, "Information Security Program Management". Contractor personnel who work in Air Force controlled/restricted areas must be trained IAW AFI 31- 101, The Air Force Installation Security Program.
2.2.2. PASS AND REGISTRATION ITEMS. The contractor shall ensure the pass and registration items required for contract performance are obtained for employees. If required, initial issuance of a Common Access Card (CAC) requires, at a minimum, the completion of a Federal Bureau of Investigation (FBI) fingerprint check with favorable results and submission of a National Agency Check with Inquiries (NACI) to the Office of Personnel Management (OPM), or a DoD-determined equivalent investigation. When required, the Government will submit NACI investigations to OPM at no cost to the contractor. Contractors cannot sponsor other contractors on base. Only Government employees (military or civilian) are authorized to sponsor contractors.
NOTICE: All contract employees shall submit to a criminal background check accomplished by Robins (ANG) Air Force Security Forces prior to the employee being issued base access credentials. Contractors must submit request for installation identification to 116/78th Security Forces Squadron not later than one
(1) week following contract award and seven (7) days prior to individual requiring entry to installation. Failure to submit requested information as indicated can result in denial or delay of issuing base access credentials.
2.2.3. RETRIEVING IDENTIFICATION MEDIA. The contractor is responsible for retrieving all identification media from employees who depart for any reason before the contract expires, e.g. terminated for cause, retirement, etc.
The contractor shall return retrieved items to the Security Forces Pass and Registration Office.
2.2.4. WEAPONS, FIREARMS, AND AMMUNITION. Contractor employees are prohibited from possessing weapons, firearms, or ammunition, on themselves or within their contractor-owned vehicle or privately- owned vehicle while on Robins (ANG) Air Force Base.
2.2.5. Controlled Unclassified Information (CUI). The contractor shall comply with 32 CFR Part 2002 on Controlled Unclassified Information. This regulation sets policy and procedures for the disclosure of records to the public and for marking, handling, transmitting, and safeguarding CUI material.
2.2.6. PHYSICAL SECURITY. The contractor shall be responsible for safeguarding all Government property and controlled forms provided for contractor use. At the end of each work period, all Government facilities, equipment, and materials shall be secured.
2.2.7. CONTROLLED/RESTRICTED AREAS. (IF APPLICABLE) The contractor shall implement local base procedures for entry to Air Force controlled/restricted areas where contractor personnel will work. Contractors will be escorted by the owner/user into all controlled/restricted areas.
2.2.8. KEY CONTROL. The contractor shall establish and implement methods of making sure all keys issued to the contractor by the Government are not lost or misplaced and are not used by unauthorized persons. The contractor shall not duplicate any keys issued by the Government.
The contractor shall immediately report to the COR or Program Manager any occurrences of lost or duplicated keys.
In the event keys, other than master keys, are lost or duplicated, the contractor may be required, upon written direction of the contracting officer, to re-key or replace the affected lock or locks without cost to the Government. The Government may, however, at its option, replace the affected lock or locks or perform re-keying and deduct the cost of such from the monthly payment due the contractor. In the event a master key is lost or duplicated, all locks and keys for that system shall be replaced by the Government and the total cost deducted from the monthly payment due the contractor.
The contractor shall prohibit the use of keys, issued by the Government, by any persons other than the contractor’s employees and the opening of locked areas by contractor employees to permit entrance of persons other than contractor employees engaged in performance of contract work requirements in those areas.
3. SPECIAL QUALIFICATIONS:
3.1. CONTRACTOR PERSONNEL. The contractor is cautioned that off-duty active military personnel hired under this contract may be subject to permanent change of station, change in duty hours, or deployment. Military Reservists and National Guard members may be subject to recall to active duty. The abrupt absence of these personnel could adversely affect the contractor's ability to perform. Their absence at any time shall not constitute an excuse for nonperformance under this contract.
3.2. CONTRACT MANAGER. The contractor shall provide a contract manager who shall be responsible for the performance of the work. Prior to start of the contract, the name of this person and alternate(s) who can act for the contractor when the manager is absent shall be designated in writing to the Contracting Officer. The contractor shall submit, in writing, to the Contracting Officer any management personnel change within one business day of the change.
The contract manager or alternate shall be available via telephone within 1 business day to meet with
Government personnel designated by the Contracting Officer to discuss problem areas.
3.3. EMPLOYEES: The contractor shall provide all personnel, equipment, tools, materials, management, training, installation, operations, supervision, logistics support and other items as defined in this PWS. The contractor technical personnel will be certified by Vindicator Security Solutions Technical Services group to install and maintain Vindicator Intrusion Detection Systems and Vindicator Command and Control Systems. Contractor shall provide employees qualified to perform electrical and electronic troubleshooting, repair, testing, diagnostics, and proprietary programming of Vindicator based annunciators.
The contractor shall furnish each employee with an identification badge. The badge shall contain as a minimum, a picture of the person, the person's name, and the name of the contractor. All badges shall be uniform, worn on the outer clothing, and be visible at all times. All employees that come in contact with Government personnel in the performance of their duties shall be able to understand and speak English.
Under the Immigration and Nationality Act (INA), employers may hire only persons who may legally work in the United States (i.e., citizens and nationals of the U.S.) and aliens authorized to work in the U.S. The employer must verify the identity and employment eligibility of anyone to be hired (Ref: U. S. Department of Labor: http://www.dol.gov/compliance/guide/aw.htm#whowhich)
4. HAZARDOUS MATERIALS: The contractor shall have approval from the Hazardous Material Management Program (HMMP) team prior to purchasing, handling, using, and storing any chemicals, solvents, lubricants, and other products that require a Material Safety Data Sheets (MSDS). The contractor shall identify these materials on a contractor Hazardous Material Inventory list. The contractor shall provide this inventory list and one copy of the MSDS for each item to the HAZMART Office for review and HMMP approval prior to any chemicals being brought onto Robins (ANG) AFB, or within 15 days of the start of this contract. This inventory is also used by the contractor to annually report hazardous material usage. By 30 January of each calendar year, the contractor shall submit two copies of the completed contractor Hazardous Material Inventory list to 116/78 CES/CEV. The contractor shall maintain one copy of the MSDS for each hazardous material line item used within the work center.
The generation of hazardous waste is not expected from this contract. It is the responsibility of the contractor to determine if hazardous waste is generated from contractor operations. 116/78 CES/CEV will assist with determination if requested by the contractor. In the event hazardous waste is generated, disposal of hazardous waste shall be handled by the Government. The generation of universal waste (including but not limited to mercury containing light fixtures) is probable under this contract. The contractor shall manage and dispose of universal waste in accordance with the base Hazardous Waste Management Plan and 40 CFR Part 273, Universal Waste Rules.
The contractor shall use the environmentally safe products when available. The contractor shall submit justification for the use of any Class I Ozone Depleting Substances (ODS) as part of the aforementioned contractor Hazardous Material Inventory submittal process. The justification shall include at a minimum:
(1) the name of the ODS; (2) the ODS quantity to be used; (3) the frequency of ODS usage; (4) the purpose for using the ODS; and (5) reasons why the ODS cannot be substituted. The contractor shall request waivers for usage of any ODS and receive approval from the Contracting Officer in writing prior to using any ODS.
The contract manager and alternate, as well as employees who handle hazardous and/or universal waste shall be required to attend Government-conducted Hazardous Waste Training. The class will be taught at Robins (ANG) Air Force Base. There will be no charge to the contractor for the training. The contractor shall contact 116/78 CES/CEV for such training. The contractor shall be required to provide proof that employees have attended the course on an annual basis. The Government may conduct a “no-notice” environmental inspection at any time.
5. CLEAN UP: The contractor shall keep interior and exterior of the contractor’s office/maintenance location and all work areas and storage areas free from accumulation of waste material and rubbish. Upon completion of the job, the contractor shall leave the work area and surrounding premises in a clean and neat condition.
Page 10 of
6. FIRE PREVENTION: The contractor is responsible for following fire prevention practices and procedures. The contractor shall provide approved storage facilities meeting National Fire Code 30, Flammable and Combustible Liquids Code, requirements for storage of flammable materials.
7. NO SMOKING POLICY: The contractor and employees shall comply with policies stating, smoking is prohibited within any Air Force Facility and use designated outdoor smoking areas.
8. ANTITERRORISM/OPERATIONS SECURITY: The contractor shall comply with all applicable installation/facility access and local security policies and procedures, which may be obtained from the Contracting Officer’s Representative (COR). The contractor shall also provide all information required for background checks to meet installation access requirements to be accomplished by the local installation’s Security Forces, Director of Emergency Services, or local Security Office. The contractor shall ensure compliance with all personal identity verification requirements as directed by DoD, HAF and/or local policy. Should the Force Protection Condition (FPCON) change, the Government may require changes in contractor security matters or processes. For Contractors that do not require CAC but require access to a DoD Facility and/or Installation. Contractor and all associated sub-contractors employees shall comply with adjudication standards and procedures using the National Crime Information Center Interstate Identification Index (NCIC-III) and Terrorist Screening Database (TSDB) (AFI 10-245, AFI 31-101 and AFMAN 31-113), applicable installation, facility and area commander installation/facility access and local security policies and procedures (provided by government representative), or, at OCONUS locations, in accordance with status of forces agreements and other theater regulations.
9. REFERENCE: SPECIFICATIONS, STANDARDS AND HANDBOOK
ESE-SIT-0001 1 Mar 13 Standardized Electronic and Security Equipment Siting and Design Guidance for Permanent Installations (Copies of above documents are available from AFLCMC/HBU, 3 Eglin Street, Bldg. 1612, Hanscom AFB, MA 01731-2100.)
Intelligence Community Directive (ICD) 705 TS, most current version.
Unified Facilities Criteria (UFC) (Copies of above document are available at: http://www.wbdg.org/references/pa_dod.php)
UFC 4-021-02 [or UFC 4-021-02NF] 1 Oct 13 Electronic Security Systems (Copies of above document is available at: http://www.wbdg.org/ccb/browse_doc.php?d=6982)
UFGS various Unified Facilities Guide Specifications (UFGS) (Copies of above document are available at: http://www.wbdg.org/references/pa_dod.php)
EIA-649B 1 Apr 11 National Consensus Standard for Configuration Management (Adopted by DoD 01 Feb 99) (Copies of above document are available through: http://www.techamerica.org/
MIL-HDBK-61A 7 Feb 01 Configuration Management Guidance (Copies of above document are available at: http://www.product-lifecycle-management.com/mil-hdbk-61a-00.htm)
AFI 31-101 30 Mar 20 Integrated Defense
W50S6Z23R0009
(Copies of above document are available from Customer)
AFPAM 63-113 17 Oct 13 Program Protection Planning for Life Cycle Management (Copies of above document is available at:
http://www.epublishing.af.mil/?txtSearchWord=AFPAM63113&client=AFPW_EPubs&pr oxystylesheet=AFPW_EPubs&ie=UTF8&oe=UTF8&output=xml_no_dtd&site=AFPW_EPu bs&btnG.x=9&btnG.y=)
HQ AF (HAF)/A4S 15 Oct 20 Configuration Management Database (CMD) Non-Nuclear IDS Equipment List (Attachment 1)
ATTACHMENT 1 - MATERIAL LIST
Know Material List Part Number: Description – Qty
Secure Room 122
550-36174-01: Enclosure Bundle, V5 SCIF Solution, includes one NEMA 1 Equipment enclosure with Tamper, 2 IP Comm Bus Surge, Grnd Bar, and pre-wired harnessing and one UL Rated 8 Circuit Distribution Panel - Qty 1 548-54000-01: AE V5 IDS - AES Encryption, Wire – Qty 1 536-33002-01: V5 SIM - Sensor Input Module, 8 Ports – Qty 5 536-33003-01: V5 ROM - Relay Output Module, 4 Ports – Qty 1 280-24033-00: Battery 12V 10AH – Qty 2 396-37272-01: Data Cabinet 45U 84"H x 24"W x 36"D-M6, Front Dr Mesh, Rear Split Mesh, Side Solid, Top Solid, Anti Tip Keyed – Qty 2 352-37132-01: 19" LCD Console Drawer w/ 8 Port KVM Switch – Qty 1 352-37133-02: KVM CPU Cable VGA, USB, 10' – Qty 1 396-36195-01: 1U Rackmount Power Strip with 12 Outlets – Qty 1 548-53100-11: AE VBM 3 Badge Manager SA Workstation (Win 10, SQL 2012) Office 2016 Pro, 32Gb RAM, RAID 1, 2U Rack Mnt -Qty 1 548-51500-11: AE SAW 2 SA Workstation (Win 10, SQL 2012) Office 2016 Pro, 32Gb RAM, RAID 1, 2U Rack Mn – Qty 1 293-37014-01: UPS Smart Online 120V 6U RM – Qty 1 293-37014-02: UPS External Battery Pack 192V Rackmount 3U – Qty 10 293-37014-03: UPS Programmable Relay I/O Card and Remote Management Adapter- Qty 1 578-37102-01: Network Switch L3 Managed 24 x 10/100/1000 RM – Qty 1 578-37106-01: Network Switch DNA License 24 Ports 3 Years – Qty 6 192-30800-00: Tamper Switch, Metal – Qty 1 550-33731-02: NEMA 1, Enclosure Assembly, Interior, Medium (<480sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 548-54100-01: AE V5 ACS - AES Encryption, Wire – Qty 4 536-33002-01: V5 SIM - Sensor Input Module, 8 Ports – Qty 2 536-33003-01: V5 ROM - Relay Output Module, 4 Ports – Qty 1 292-37237-02: Power Supply 10A 12VDC w/ Encl 16 Outputs, 2A PTC – Qty 1 280-24033-00: Battery 12V 10AH – Qty 3 292-37276-01: Power Supply 6A 12/24VDC 115VAC BC300 Encl – Qty 1 292-32316-02: Power Distribution – Qty 3 292-33297-00: Power Supply, 12/24VDC, 6A, w/charger, UL Listed – Qty 1 396-37142-01: Custom RM Encl w/ BP 1BL1R – 1 396-37277-01: Trove RM Enclosure for Altronix PS Backplane – 1
548-54300-01: AE V3 ACS - AES Encryption, Wire – Qty 2
VBM Equipment for Rm. 113
340-37024-01: Workstation Monitor 24" – Qty 1 332-33756-00: Video Badging Camera Package – Qty 1 352-33692-01: VBM Signature Pad – Qty 1 360-32487-01: Photo Badging Printer (2 Sided) – Qty 1 364-32526-00: Ribbon Cartidge Badge Printer – Qty 4 574-32690-00: Cleaning Kit, Badge Printer – Qty 4 476-32741-01: HID Prox RFID Cred. - ISO Prox II Card (Request Card Range and Facility Code. – Qty 500 578-37006-01: Wizard SRX KVM Extender / Dual Headend DVI-D USB 2.0 Audio, Single-Access CATX – Qty 1 578-37006-02: KVM Extender Chassis – Qty 1 578-37006-04: Spare Power Supply for Wizard KVM Extenders – Qty 1
Main Entry (112) 192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 316-37229-01: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount -Qty 1 540-33739-00: EOL Resistor Pack w/ Flying Leads (1 each) – Qty 2 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-36120-07: PIVClass Credential Reader w/Keypad. Reads Prox and CACII (75BIT) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 950-33726-00: Connection to LKM style lock – Qty 1 548-52000-11: AE VSC Site Commander (Win 10) – Qty 1 340-37024-01: Workstation Monitor 24"- Qty 1 950-33726-00: Monitor Mount – Qty 1 332-37215-01: Network Camera Streamlined HDTV 1080p Fixed Dome- Qty 1.
336-37216-01: Video Decoder Discrete 1080p with HDMI output – Qty 1 578-37254-01: PoE Injector – Qty 1
RM.114
316-37229-01: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 540-33739-00: EOL Resistor Pack w/ Flying Leads (1 each) – Qty 2 950-33726-00: J-Box (Handy and or 1900) – Qty 1
RM.115
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 2 316-32497-00: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 540-33739-00: EOL Resistor Pack w/Flying Leads (1 each) – Qty 2
RM.116
316-37229-01: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1
RM.119
316-37229-01: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1
RM.120
316-37229-01: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1
RM.128
316-37229-01: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1
Stair 130
316-37229-01: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1
Armory #1
192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-07: PIVClass Credential Reader w/Keypad. Reads Prox and CACII (75BIT) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 950-33726-00: Strike – Qty 1 316-32965-01 RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00 RTE PIR - Light Gray – Qty 1
Hanger Doors
540-33739-00: EOL Resistor Pack w/ Flying Leads (1 each) – Qty 1
192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1
Hanger Man Doors 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 2 192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 2 540-33739-00: EOL Resistor Pack w/ Flying Leads (1 each) – Qty 1
Hanger Door Motions 316-37007-01: BEA LZR-s600 Motion Sensor - 10LZRS600 – Qty 3 316-37007-03: BEA LZR Mounting Bracket Accessory - 10LBA – Qty 3 316-37007-06: BEA Universal Remote Control - 10REMOTE – Qty 1
Hanger Motions 312-32931-08: Dual Tech Sensor, Microwave and PIR, Indoor, Wide Angle – Qty 4
Hanger – Outside Detection Sensors 579-33752-03: IPIDS, Tall Zone, 12 snsrs, Anti-Clmb,Anit-Tmpr,12'x5"sqr – Qty 1 579-37131-01: IPIDS Adapter Plate – Qty 1
Hanger Horn/Strobes 274-37203-01: Signal Horn 12 to 24 VDC 99 dBa – Qty 4 274-37203-02: Signal Horn Weatherproof Backbox - Qty 4
Stair 131
316-37229-01: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1
RM.102
316-37229-01: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1
RM.107
316-37229-01: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1
RM.108 Roll Up Door
192-37019-02: Roll-up Door Bracket Kit - Left Side – Qty 1 316-37229-01: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1
Entry to Hanger from 112
192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-36120-07: PIVClass Credential Reader w/Keypad. Reads Prox and CACII (75BIT) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 950-33726-00: Strike – Qty 1
RM.128
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 950-33726-00: Strike – Qty 1 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1
RM.120
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Locking Hardware – Qty 1
RM.119
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1
950-33726-00: Strike – Qty 1
RM.116
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM.115
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Locking Hardware – Qty 1
RM. 238
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1
RM.237
192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM.235
550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM.236
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM.234
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM.227
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM.221
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1
104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM.219
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM.216
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Locking Hardware – Qty 1
RM.215
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM.209
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1
RM.208
192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM.207
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM.205
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM.202
192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1
Armory #2 (Second Floor)
550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-07: PIVClass Credential Reader w/Keypad. Reads Prox and CACII (75BIT) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 316-32965-01: RTE PIR Trim Plate - Light Gray – Qty 1 316-32965-00: RTE PIR - Light Gray – Qty 1 950-33726-00: Strike – Qty 1
RM. 224 (Second Floor) 192-36234-00: BMS, Level 2 SPDT, with Shim and Bracket – Qty 1 316-37229-01: PIR 360 Degree Ceiling Mount – Qty 1 104-32497-00: Resistor 2.2K – Qty 2 192-36031-02: J-Box Tamper Switch Clip Mount – Qty 1 540-33739-00: EOL Resistor Pack w/ Flying Leads (1 each) – Qty 2 550-33731-01: NEMA 1, Enclosure Assembly, Interior, Small (<240sq"), (Encsr,B/P,Tamper Sw,Medco Lock,Duplex,On/Off Sw,A/C Surge,Grnd Bar) – Qty 1 574-36120-08: PivClass Credential Reader w/no keypad, reads Prox and CAC II (75 bit) (Terminal) – Qty 1 574-36120-07: PIVClass Credential Reader w/Keypad. Reads Prox and CACII (75BIT) (Terminal) – Qty 1 574-32658-02: MR-50 Portal Controller, Wiegand, Single keypad, 2-Input – Qty 1 104-33248-00: Resistor 1K 1% - Qty 4 950-33726-00: Connection to LKM style lock – Qty 1 548-52000-11: AE VSC Site Commander (Win 10) – Qty 1
CCTV
HC35W45R2: NDAA Compliant, 120 db WDR 5 MP IR MFZ RUGGED DOME, 2.7-13.5MM, POE, ONVIF S/T/G – Qty 8 HA60WLMB1: 60S Wall Mount Bracket, 1.5NPT female – Qty 7 HA35PMC02: 35S MFZ Camera Cap, 1.5NPT Male – Qty 7 HA35CLM01: 35S Ceiling mount base with adapter – Qty 1 HN35080216: S35 8 Chs NVR 4K, 8 Chs POE, 16 TB,2HDD – Qty 1 396-37209-01: 24U Rack Elite Server Cabinet M6 – Qty 1 950-33726-00: VMS UPS – Qty 1 HMW7T: Honeywell Workstation Gen 7, Quad Monitor – Qty 1 340-37027-01: Workstation Monitor 27" – Qty 2 950-33726-00: Power Strip – Qty 1 950-33726-00: Small UPS for workstation and monitor, non rack mount – Qty 1 578-37220-01: RJ45 Connectors (50 Pack) – Qty 1
Cable and Conduit 460-35582-02: CABLE - 16/2 STR JKT 1000' Box White – Qty 4 456-37221-01: CABLE - 18 AWG 2 Stranded Cond, PVC 1000' Box Gray – Qty 5 456-35210-01: CABLE - 22/8 STR JKT CL2P 1000' Box Natural – Qty 8 456-37002-01: CABLE - 18/8 STR OAS CL2P 1000' Reel Natural – Qty 1 456-35871-01: CABLE - RS485 24/2 Twisted Pair 1000' – Qty 1 456-37244-01: CABLE - CAT6 Plenum 1000' Gray – Qty 1 458-32791-01: Conduit 3/4" x 10' EMT – Qty 700 458-33720-02: Conduit Flex 3/4" x 100' – Qty 1 950-33726-00: Conduit Connectors, Boxes, Straps Etc. – Qty 2
Section E - Inspection and Acceptance
INSPECTION AND ACCEPTANCE TERMS
Supplies/services will be inspected/accepted at:
CLIN INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY
0001 Destination N/A Destination Government
Section F - Deliveries or Performance
DELIVERY INFORMATION
CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC /
CAGE
0001 29-FEB-2024 1 116 ACW/COMMUNICATIONS F6X3D2
RANDALL EVANS
525 BORGHESE DRIVE
BLDG 2079
ROOM 5
ROBINS AFB GA 31098
478-201-4320 FOB: Destination
F6X3D2
Section I - Contract Clauses
CLAUSES INCORPORATED BY REFERENCE
52.203-3 Gratuities APR 1984 52.203-6 Restrictions On Subcontractor Sales To The Government JUN 2020 52.204-9 Personal Identity Verification of Contractor Personnel JAN 2011 52.204-10 Reporting Executive Compensation and First-Tier
Subcontract Awards
JUN 2020
52.204-18 Commercial and Government Entity Code Maintenance AUG 2020 52.204-21 Basic Safeguarding of Covered Contractor Information
Systems
NOV 2021
52.204-23 Prohibition on Contracting for Hardware, Software, and Services Developed or Provided by Kaspersky Lab and Other Covered Entities
NOV 2021
52.204-25 Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment
NOV 2021
52.204-27 Prohibition on a ByteDance Covered Application JUN 2023 52.209-9 Updates of Publicly Available Information Regarding
Responsibility Matters
OCT 2018
52.212-4 Contract Terms and Conditions--Commercial Products and Commercial Services
DEC 2022
52.219-1 Alt II (Dev)
Small Business Program Representations (Deviation 2023- O0002) Alternate II
MAR 2023
52.219-4 Notice of Price Evaluation Preference for HUBZone Small Business Concerns
OCT 2022
52.219-6 Notice Of Total Small Business Set-Aside NOV 2020 52.219-14 (Dev) Limitations on Subcontracting (DEVIATION 2021-O0008) FEB 2023 52.219-28 Post-Award Small Business Program Rerepresentation MAR 2023 52.222-3 Convict Labor JUN 2003 52.222-19 Child Labor -- Cooperation with Authorities and Remedies DEC 2022 52.222-21 Prohibition Of Segregated Facilities APR 2015 52.222-26 Equal Opportunity SEP 2016 52.222-50 Combating Trafficking in Persons NOV 2021 52.223-15 Energy Efficiency in Energy-Consuming Products MAY 2020 52.224-1 Privacy Act Notification APR 1984 52.224-2 Privacy Act APR 1984 52.224-3 Privacy Training JAN 2017 52.232-33 Payment by Electronic Funds Transfer--System for Award
Management
OCT 2018
52.232-39 Unenforceability of Unauthorized Obligations JUN 2013 52.232-40 Providing Accelerated Payments to Small Business
Subcontractors
MAR 2023
52.233-1 Disputes MAY 2014 52.233-3 Protest After Award AUG 1996 52.249-2 Termination For Convenience Of The Government (Fixed-
Price)
APR 2012
52.249-8 Default (Fixed-Price Supply & Service) APR 1984 252.201-7000 Contracting Officer's Representative DEC 1991 252.203-7000 Requirements Relating to Compensation of Former DoD
Officials
SEP 2011
252.203-7002 Requirement to Inform Employees of Whistleblower Rights DEC 2022 252.203-7003 Agency Office of the Inspector General AUG 2019 252.204-7000 Disclosure Of Information OCT 2016
252.204-7003…